SINEAX I 552 Transducer for AC current
|
|
- Allyson Jacobs
- 5 years ago
- Views:
Transcription
1 SNEAX 55 With power supply RMS value measurement, with measuring ranges Carrying rail housing P/0 Application he transducer SNEAX 55 (Fig. ) converts a sinusoidal or a distorted AC current into a load independent DC current or a load independent DC voltage proportional to the measured value. he transducer fulfi ls all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (EC 00 resp. EN 00). t was developed and is manufactured and tested in strict accordance with the quality assurance standard SO 00. Fig.. ransducer SNEAX 55 in housing P/0 clipped onto a top-hat rail. Features / Benefits Measuring input: AC current, sine or distorted wave forms, RMS value measurement Measured variable AC current Measuring range limits 0 0. / 0.5 to 0. / A Measuring output: Unipolar or live zero output variables Measuring principle: Logarithmic method AC/DC power supply / Universal Standard version as per Germanischer Lloyd Following fi ltration by means of an active fi lter, the transformation properties of the measuring transducer are determined in the succeeding characteristics circuit. he output amplifi er transforms the measuring signal into an impressed DC current output signal A. he electronic components are supplied with voltage H from the mains supply unit. ~ H eff = i dt o A Mode of operation nput signal ~ is galvanically separated from the mains network using a transformer. he following mathematical expression is then formed using a root-mean-square value computer eff = o i dt Fig.. Block diagram. echnical data General Measured quantity: Measuring principle: AC current Sine or distorted wave forms RMS value measurement Logarithmic method Camille Bauer Data sheet 55 Le 0.0
2 SNEAX 55 Measuring input E Nominal frequency f N : 50/0 or 400 Hz Nominal input current N (measuring range end value): Measuring range limit values 0 0. / 0.5 to 0 <. / A Measuring range end value ratio : 5 Setting: Own consumption: Overload capacity: Admissible alteration of full scale output, variable sensitivity, adjustable with potentiometer Setting range N (± 5%) 00% 0Output N 0 nput VA with input end value Measured Duration of nterval between Number of quantity one two successive applications N application applications. N continuously 0 N 0 s 00 s Measuring output A Load-independent DC current: Burden voltage: 0 to 0 0 ma resp. live-zero 0. to 4 0 ma 5 V 5 V External resistance: R ext max. [kω] = AN [ma] AN = Output current end value Load-independent DC voltage: 0 to 0 0 V resp. live-zero 0. to 0 V External resistance: R ext [kω] U [V] A ma Current limit under overload: Voltage limit under R ext = : 5 V.5 AN at current output Approx. 0 ma at voltage output Residual ripple in output current: Setting time: 0.5% p.p. at setting time 00 ms % p.p. at setting time 50 ms 50 ms or 00 ms Power supply H AC/DC power pack (DC or Hz) able : Rated voltages and permissible variations Rated voltage olerance 5 0 V DC / AC DC 5 + % 4 0 V DC / AC AC ± 5% Option: Power consumption: Accuracy (acc. to EN 0 ) Reference value: Connected to the low tension terminal side and 4 V AC or 4 0 V DC.5 W resp. VA Output end value Basic accuracy: Class 0.5 Reference conditions: Ambient temperature 5 0 C nput variable Rated operating range Frequency f N ± Hz Curve shape Sine-wave Crest factor Power supply n rated range Output burden Current: 0.5 R ext max. Voltage: R ext min. Warm-up time 5 min. nfluence effects (maxima): included in basic error Frequency Hz, ± 0.% Hz, ± 0.5% Crest factor.5 ± 0.% >.5 ± 0.5% Safety Protection class: (protection isolated, EN 00) Housing protection: P 40, housing (test wire, EN 0 5) P 0, terminals (test fi nger, EN 0 5) Contamination level: Overvoltage category: Rated insulation voltage 00 V, input (versus earth): 0 V, power supply 40 V, output Data sheet 55 Le 0.0 Camille Bauer
3 SNEAX 55 est voltage: 50 Hz, min. acc. to EN V, input versus all other circuits as well as outer surface 00 V, power supply versus output as well as outer surface 40 V, output versus outer surface Storage temperature: 40 to + 0 C Relative humidity of annual mean: 5% Altitude: 000 m max. ndoor use statement! nstallation data Mechanical design: Housing P/0 Material of housing: Lexan 40 (polycarbonate), fl ammability Class V-0 acc. to UL 4, self-extinguishing, non-dripping, free of halogen Mounting: Mounting position: Weight: Connecting terminals Connection elements: Permissible cross section of the connection leads: Environmental conditions For rail mounting Any Approx. 0. kg Screw-type terminals with indirect wire pressure 4.0 mm single wire or.5 mm fi ne wire Operating temperature: 0 to + 55 C Ambient tests EN 0 0--: Acceleration: Frequency range: Number of cycles: EN 0 0--: Acceleration: EN 0 0--/-/-: EC /-/-4/-5/- EN 55 0: Germanischer Lloyd ype approval certifi cate: Ambient category: Vibration: Vibration ± g khz, rate of frequency sweep: octave/minute 0, in each of the three axes Shock x 50 g shocks each in directions Cold, dry heat, damp heat Electromagnetic compatibility No. 5- HH C 0. g able : Standard version he following transducer version is available as standard version. t is only necessary to quote the Order No.: Nominal frequency Measuring range by changing connections Output signal Power supply DC or Hz Setting time Order No. 50/0 Hz 0.0 A / 5 A 4 0 ma 5 0 V 00 ms 0 he complete order code according to able : Specifi cation and ordering information must be stated for versions other than the basic version and for special confi gurations. able : Specification and ordering information (see also able : Standard version) Description *Blocking code No-go with blocking code Article No./ Feature SNEAX 55 Order Code 55 - xxxx xx 55 Features, Selection. Mechanical design Housing P/0 for rail mounting 4. Nominal input frequency 50 / 0 Hz 400 Hz Camille Bauer Data sheet 55 Le 0.0
4 SNEAX 55 Description *Blocking code No-go with blocking code Article No./ Feature SNEAX 55 Order Code 55 - xxxx xx 55 Features, Selection. Measuring range 0 / 5 A 0. / A Non-standard 0 0./0.5 to 0 <. / Measuring range end value ratio : 5 4. Output signal [A] 0 0 ma, R ext 50 Ω 4 0 ma, R ext 50 Ω Non-standard 0.00 to 0 < 0 0. to < (4 0) [ma] 0 0 V, R ext 5 kω A Non-standard 0.00 to 0 < 0 0. to 0 5. Power supply [V] Z 5 0 V DC/AC 4 0 V DC/AC 4 V AC / 4 0 V DC, low tension 5. Setting time 0. s 50 ms * Lines with letter(s) under «no-go» cannot be combined with preceding lines having the same letter under Blocking code. Electrical connections Fig.. For measurement with st (lower) measuring range, power supply connected to terminals and. Fig. 4. For measurement with nd (higher) measuring range, power supply connected to terminals and. 0 0 ( )(+) ( )(+) 4 Data sheet 55 Le 0.0 Camille Bauer
5 SNEAX 55 ( )(+) Fig. 5. For measurement with st (lower) measuring range, power supply connected to the low tension terminal side and. ( )(+) Fig.. For measurement with nd (higher) measuring range, power supply connected to the low tension terminal side and. 0 0 = Current measuring input = Measuring output = Power supply Dimensional drawing Fig.. SNEAX 55 in housing P/0 clipped onto a top-hat rail (5 5 mm or 5.5 mm, acc. to EN 50 0). Rely on us. Camille Bauer AG Aargauerstrasse CH-50 Wohlen / Switzerland Phone: + Fax: info@camillebauer.com Subject to change without notice Edition 0.0 Data sheet 55 Le
SINEAX U 553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
More informationSINEAX G 536 Phase Angle or Power Factor Transducer
SIEAX G Carrying rail housing P/0 Application The transducer SIEAX G (Fig. ) measures the phase angle or power factor between current and voltage of a single or -phase balanced network having a sine wave
More informationSINEAX G 537 Transducer for Phase Angle Difference
Carrying rail housing P/0 pplication The transducer SINX G 5 (Fig. ) converts the phase angle difference of two synchronised supplies into a load independent DC current or a load independent DC voltage
More informationSINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar
SINEAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. ) is to electrically insulate input and
More informationEMBSIN 281 G Power factor transducer
EMBSI 8 G Carrying rail housing MBS/SP Application The transducer EMBSI 8 G (Fig. ) measures the power factor between current and voltage of a single or 3-phase balanced network having a sine wave form.
More informationSINEAX TV809, 1 channel Programmable Isolating Amplifier
For electrically insulating, ampliflying and converting DC signals 0102 II (1) Ga II (1) Da Application The purpose of the isolating amplifi er SINEAX TV809 (Fig. 1) is to electrically insulate input and
More informationSINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar
For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output
More informationSINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage
Application The transducers SINEAX I 503/U 504 (Figs. 1 and 2) are designed to convert a sinusoidal AC current or voltage into a load independent DC signal proportional to the measured value. This output
More informationSINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex
for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate
More informationSINEAX B 811 Power Pack with additional Functions
SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers
More informationTheta 20A / 20V. Technical Data Sheet. Special Features
Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in
More informationPlug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar
for electrically insulating, amplifying and converting DC signals 0102 II (1) G pplication The purpose of the isolating amplifi er SIRX T 808 (Fig. 1) is to electrically insulate input and output signals,
More informationPlug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs
Plug-in module, or channels Application The programmable transmitter (Fig. ) is designed for measuring temperature in combination with thermocouples or resistance thermometers. Thermocouple non-linearities
More informationRISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar
Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power
More informationSINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator
SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically
More informationn True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)
Tranducers for alternating current/voltage n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) and input current range (for CIP-I) n Available in single or dual output type
More informationSINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs
SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.
More informationSINEAX TI 807 Passive DC signal isolator
without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate
More informationTheta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.
Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta
More informationEURAX UI 505, Combined Transducer for AC current and AC voltage
Plug-in module in Euro-format Application The transducers EURAX UI 505 (Fig. 1) are intended to simultaneous converts of up to 3 sinusoidal AC currents or voltages. Output signals available are load-independent
More informationRISH Ducer E13 3 channel transducer for AC current and voltage
RISH Ducer E13 3 channel transducer for C current and voltage The RISH Ducer E13 ( Fig. 1) converts 3 sine wave C current or C voltage into 3 output signals that can serve several receiving instruments
More informationTheta Hz. Technical Data Sheet. Special Features
Technical Data Sheet Theta Hz Theta Hz the transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent
More informationKINAX 2W2 Programmable Transmitter for Angular Position
Application The KINAX 2W2 (Figs. 2 and 3) converts the angular position of a shaft into a load independent direct current signal, proportional to the angular position. The unit is contact free and has
More informationPlug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex
for electrically insulating, amplifying and converting DC signals, also designed for FSK 002 II () G pplication The purpose of the isolating amplifi er SIRX TV 808 (Fig. ) is to electrically insulate input
More informationKINAX WT 717 Programmable Transmitter for Angular Position
Ruggedized version Application The KINAX WT 717 (Fig. 1) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact
More informationSINEAX V 604s Programmable multifunctional transmitter
SINEAX V 60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers 00 SINEAX V60s is a multifunctional transmitter f top-hat rail assembly with the following main characteristics:
More informationPlug-in module SIRAX TI 807 Passive DC signal isolator
without power supply, x- and non-x version 0102 II (1) resp. II (2) pplication The signal isolator SIRX TI 807 (Fig. 1) serves to electrically insulate the analogue DC signal in the range 0 20 m which
More informationRISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS
RISH Ducer 5 TRNSDUCR FOR C CURRNT OR C VOLTG WITH DIFFRNT CHRCTRISTICS The RISH Ducer 5 transducer (Fig and ) is used where a sine-wave C current or voltage is to be converted into a DC signal proportional
More informationKINAX SR 719 Programmable Transmitter for Position Feedback
Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 719 (Figs. 1 and 2) is used to measure and transmit linear displacement (stroke) on various types of
More informationRISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics
RISH Ducer E13 Transducer For c Current Or c Voltage With Different Characteristics Data Sheet For Measurement of C Current or C Voltage Fig. 1. RISH Ducer E13 clipped onto a top - hat rail. Fig. 2. RISH
More informationSINEAX V604s Programmable multifunctional transmitter
SINAX V60s for direct currents, direct voltages, temperature sensors, teletransmitters or potentiometers SINAX V60s is a multifunctional transmitter for tophat rail assembly with the following main characteristics:
More informationSINEAX / EURAX 2I1 Passive DC signal isolator
SINEAX / EURAX I without power supply 0 II () G resp. II () G Application The DC signal isolator SINEAX/EURAX I (Figs. and ) serve to isolate load-independent DC current signals. It suppressed noise voltages
More informationSINEAX VC 603, Programmable combined transmitter/alarm unit
for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Fig. 1) converts the input variable a DC current or voltage, or a signal
More informationZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer
nalogue Meters With Moving - Iron Movement pplication IEGER PR-P The iegler PR-P transducer is used to measure and convert active, reactive, apparent power, Phase angle & Power Factor of a Single-phase
More informationKINAX 3W2 Transmitter for angular position
KINX 3W2 For installation KINX 3W2 is a compact transmitter for angular position for installation in devices and apparatus. Due to its unique capacitive measuring principle, it acquires the angular position
More informationMeasuring Transducer MT4xx series Programmable AC Current Transducer MT418
Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz
More informationData Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2
Data Sheet 066.8e Transducers for Active and Reactive Power EW 2.2 DGW 2.2 VGW 2.2 DUW 2.2 VUW 2.2 Application The E/DG/VG/DU/VU W 2.2 power transducers convert all forms of active and reactive power polarity
More informationSUBJECT TO CHANGE WITHOUT NOTICE
TRNSUCERS & ISTRS Theta 30P www.sifamtinsley.co.uk TSHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders igital Panel Meters Current Transformers
More informationSINEAX V 604 Programmable universal transmitter
for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The universal transmitter SINEAX V 604 (Figures 1 and 2) converts the input variable a DC current
More informationKINAX WT 707 Transmitter for angular position
Ruggedized version pplication The KINX WT 707 (Figs. 1 to 6) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact
More informationCoupling Relays and Converters
Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard
More informationPOWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL
POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK PP, PP and PB ISO 900 C E R T Y F I K A T 4 mm SERVICE MANUAL Contents Page. APPLICATION... 2. BASIC REQUIREMENTS.... TRANSDUCER SET... 4 4. TECHNICAL
More informationProgrammable AC Voltage Transducer MT416
Programmable AC Voltage Transducer MT416 RMS AC voltage or frequency measurements Voltage auto measurements up to 600 V L-N Frequency measurement 16 400 Hz AC or universal wide auiliary power 24 300 Vdc,
More informationProgrammable AC Current Transducer MT418
Programmable AC Current Transducer MT418 RMS AC current measurements Current auto range measurements up to 12 A Frequency measurement range 16 400 Hz AC or universal wide auiliary power supply range 24
More informationEA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters
EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters EA12 EA19 EA17 EA16 EB16 APPLICATION EA16, EB16, EA17, EA19 and EA12 moving-iron meters are intended for measuring AC voltage or
More informationVariTrans P D1 TRMS
Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings VariTrans P 41000 D1 TRMS VariTrans P 41000 TRMS AC/DC High-Voltage Transmitters With True
More informationZITARES CCD FX-20 25W SELV (isolated), adjustable functions and current, 1-channel, dimmable
Sample image ECG versions Model Order no. Output current 1) Output power CCD175-25FX-20/220-240/LI 10132980 100... 750 ma 2... 25 W 1) Adjustable by means of zitares360 software or resistor. Performance
More informationfor DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits
SINEAX VC 603, Programmable for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Figs. 1 and 2) converts the input variable a
More informationFluke 83V and 87V Digital Multimeters
Fluke 83V and 87V Digital Multimeters Detailed Specifications For all detailed specifications: is given as ±([% of reading] + [number of least significant digits]) at 18 C to 28 C, with relative humidity
More informationRudder or propeller angular position transmitter KINAX WT720
Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to
More informationTRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs
More informationDATA SHEET AC current single function transducer TAC-311DG/TAC-321DG
DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG Compact design, 55 x 75 mm Easily accessible terminals Accuracy class 0.5 35 mm DIN rail or base mounting DEIF A/S Frisenborgvej 33
More informationVariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.
ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task
More informationTVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active
Technical manual BA 0318 Signal converter Isolation amplifier active for galvanic isolation, conversion and adjustment of electrical standard signals Evaluable input signals Direct voltage 0...10V / 0...1V
More informationMBS AG EMBSIN 120 UV. without auxiliary voltage supply housing for 35 mm DIN rail mounting
EMBSIN 120 UV Measuring transducers for AC current : Sinus-shaped alternating voltage (0 20 A or 0 500 V) : Unipolar output signal measuring principle: Rectifier mean value measurement process economic
More informationIt s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P TRMS series. Isolation Amplifiers.
It s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P 40000 TRMS series Isolation Amplifiers Isolation Amplifiers A Class of Its Own. AC/DC High-Voltage With True
More informationCP-E range Benefits and advantages
Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A
More informationProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv
Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv When temperatures are to be measured using Pt100 resistance thermometers in high-voltage environments, standard temperature transmitters
More informationZelio Control Measurement Relays
Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and
More informationHigh-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000
High-Voltage Isolation Amplifiers / Shunt Isolators VariTrans P 29000 Compact high-voltage isolators with safe galvanic isolation, VariPower broad-range power supply and genuine calibrated range selection.
More informationDEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions
Installation and start up instructions TAS-311DG Selectable AC transducer Voltage, current, frequency or phase angle transducer Supply voltage up to 690V DEIF A/S Configuration via PC-interface possible
More informationDATA SHEET Selectable AC transducer TAS-311DG
DATA SHEET Selectable AC transducer Measuring on AC networks Class 0.5 (IEC688) measurement Supply/measur. voltage up to 690 V Easy configuration via PC interface possible DEIF A/S Frisenborgvej 33 DK-7800
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationEMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.
Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed
More informationCP-T range Benefits and advantages
Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers
More informationSEPARATOR P20G TYPE USER S MANUAL
SEPARATOR P20G TYPE USER S MANUAL 1 2 Contents 1. APPLICATION... 5 2. SEPARATOR SET... 5 3. OPERATIONAL SAFETY... 6 4. FITTING... 7 4.1. Fixing Way... 7 4.2. External Connection Diagrams... 8 5. SERVICE...
More informationProduct Guide. Transducers
x y Product Guide Transducers 800.U.001.01 P/Q f for AC Current or AC Voltage: A1U / V1U 2.2 also self-powered: AU / VU 2.0 for Active or Reactive Power in single phase systems: EW / EB 2.2 in balanced
More informationSIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions
Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationXUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)
XUA1 AC Voltage and phase balance relay (August 1996) Manual XUA1 (Revision New) Woodward Manual XUA1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
More informationZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable
ECG versions Model Order no. Output current 1) Output power NCD140-70FX-30/220-240/LI 10142659 100... 400 ma 10... 70 W NCD175-100FX-30/220-240/LI 10142661 350... 750 ma 35... 100 W 1) Adjustable by means
More informationRISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:
Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit
More informationPower consumption In operation At rest For wire sizing
echnical data sheet GM4A-SR-P Modulating damper actuator for operating air control dampers in ventilation and airconditioning systems for building services installations For air dampers up to approx. 8
More informationHigh-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS
AC/DC high-voltage isolators for true rms measurement Input currents ranging from Iin = 100 ma AC to Iin = 5 A AC The Task In electrical systems, alternating currents from 100 ma to 5 A need to be recorded,
More informationBtdin RCD Add-on modules 63A for MCBs 1,5 modules per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and
More informationElectronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact
Data sheet Electronic timer CT-SDE Star-delta change-over with n/c + n/o contact The CT-SDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic
More informationRISH Ducer IXX / VXX Series (TRMS/Average) Transducer for AC current / AC Voltage (Single or Dual Output)
RISH Ducer IXX / VXX Series (TRMS/verage) Transducer for C current / C Voltage (Single or Dual Output) Data Sheet Transducer for C Current and C Voltage Fig. 1. RISH Ducer I11 in housing E16 clipped onto
More informationZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable
Sample Image ECG versions Model Order no. Output currents 1) Output power NCD140-70FX-30/220-240/LI 10142659 1 x 100... 400 ma 5... 70 W NCD175-100FX-30/220-240/LI 10142661 1 x 350... 750 ma 14... 100
More informationType: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description
Type: EASY719 DA RC Article.: 274117 Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationHigh-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS
High-Voltage Isolation Amplifiers / Shunt Isolators AC/DC high-voltage isolators for true rms measurement Input voltages up to Vin = 3600 V AC The Task In electrical systems, alternating voltages from
More informationElectronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E
More informationPTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device
MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor
More informationDigital I/O Coupler (4-wire) Series 9413/21
Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationConnection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition
Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω
More informationZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable
ECG versions Model Order no. Output currents 1) Output power ICD290-60LS-01/220-240/LI 10105905 2 x 250-900 ma 5-60 W ICD290-100LS-01/220-240/LI 10105906 2 x 250-900 ma 12.5-95 W 1) Adjustable for each
More informationTPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3
, Features High power density 40 W power supply (enclosed / open frame) 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Ready to meet ErP directive, < 0.3
More informationVariTrans P V. Safe and Sound.
1000 V. Safe and Sound. VariTrans P 29000 Compact high-voltage isolation amplifiers with safe galvanic isolation, VariPower broad-range power supply and genuine calibrated range selection. Isolation Amplifiers
More informationAnalog signal converters CC range
Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationFor non-electrical quantities
Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data
More informationExtension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..
echnical data sheet Mechanical accessories for SM..A.. Extension for ground plate Z-SMA Extension from SM.. or AM.. to SM..A.. Galvanized steel Shaft extension AV8-25 Length approx. 250 mm For damper spindles
More informationUSER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2
(ENG) DECEMBER 2017 USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2 ISOLATOR - SIGNAL CONVERTER TYPE SP 11 CURRENT
More informationZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable
ECG versions Order number ICD90-0QS-0/0-0/LI 00907 ) ) Output current Total power output x 0... 900 ma... 0 W Additional output currents can be selected by parallel connection of the outputs of the ECG,
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More informationPaladin Transducers 250 Series Class 0.5 and Class 0.2
Paladin Transducers 250 Series Class 0.5 and Class 0.2 An extensive range of transducers providing measurement, isolation and conversion of electrical parameters into industry standard DC output signals.
More informationIsolating Repeater Input Series 9163
> For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de
More informationPOWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR
POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR The T-W or T-V power transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watts)
More information