RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Size: px
Start display at page:

Download "RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar"

Transcription

1 Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power supply, prevents falsified measurement due to spurious potentials. Flexibility provided by more than 50 different input and combinations selected by simply positioning soldered jumpers, helps in reduced stocking. Precesses unipolar / bipolar and live zero signals provision for raising burden and signal conversion Green LED signals device in operating condition. High Electrical Insulation between input and -.3 kv, and power supply versus all other circuits kv Provision fo either snapping the isolating amplifier onto top - hat rails or securing it with screw to a wall or panel. For electrically insulating, amplifying and converting DC signals Application The purpose o the isolating amplifier RISH Ducer TV 808 (Fig.1) is to electrically insulate and signals, respectively to amplify and / or change the signal level or type (current or voltage) of the input signals. The amplifier fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and safely (IEC 1010 resp. EN ). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 001. The device has two channels and provides two independent isolating amplifiers in an extremely small space. The user has a wide choice of input and ranges and can set the desired one with the aid of soldered jumpers and potentiometers. A version with one input and two s is available that enables two electrically insulated s to be obtained from a signal input signal. Function Isolating Amplifier RISH Ducer TV808, finds its application for isolation amplification and conversion of DC signals. RISH Ducer TV 808 isolates the DC signal to prevent falsified readings due to interference at input. RISH Ducer TV808 amplifies unipolar / bipolar input by easy. Onsite, simple positioning of soldered jumpers to raise the burden capacity. Standard Electromagnetic compatibility The standards DIN EN & DIN EN are observed Protection (acc. to IEC 5 resp. EN 60 5) Housing IP 40 Terminals IP 0 Electrical standards Acc. to IEC 1010 resp. EN Operating voltages Contamination level Overvoltage category acc. to IEC 664 < 300 V between all insulated circuits Double insulation Power supply versus all other circuit Measuring input versus measuring Test voltage III for power supply II for measuring input and measuring Power supply versus all 3.7 kv, 50 Hz, 1 min Measuring inputs Versus measuring s.3 kv, 50 Hz, 1 min. Measuring inputs 1 Versus measuring inputs.3 kv, 50 Hz, 1 min. Measuring inputs 1 Versus measuring s.3 kv, 50 Hz, 1 min. Tel , 00 Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in

2 Standard version Inputs and s set to ma. Any of the standard ranges given in the Section "Technical data, measuring inputs" are simply selected by positioning soldered jumpers. The fine adjustment is accomplished using the potentiometers "ero" and "Span". Table 1 Standard version with inputs and s Standard range Power supply Order Inputs Outputs No. 1 and 1 and 0 0mA Table Standard version with 1 input and s Standard range Power supply Order Input Outputs No. 1 1 and 0 0mA 0 0mA 0 0mA 4 60 V DC/AC V DC/AC V DC/AC V DC/AC Please complete the Order Code according to "Table - 4 Ordering information" for versions with user - specific input and / or ranges. Technical Data Measuring inputs DC current ma 0 0. ma ma 0 1 ma 0 ma 0 5 ma 0 10 ma 0 0 ma 0. 1 ma 1 5 ma 10 ma 4 0 ma to ma start value > 0 to < 50 % final value or span 0.1 to 40 ma between -40 and 40 ma also bipolar asymmetrical R = 15 i ma ma ma ma + ma ma ma ma DC voltage V V 0 0. V V 0 1 V 0 V 0 5 V 0 10 V 0 0 V 0 40 V 0. 1 V 1 5 V 10 V 4 0 V to start value > 0 to < 50 % final value or span 0.06 to 40 V between -40 and 40 V also bipolar asymmetrical R = 100 k i Overload Measuring s DC currents Burden voltage External resistance DC voltage Burden 1 V 1 V R ext max. [k ] = I AN [ma] V V V V + V V V 0 +0 V DC current continuously - fold DC voltage continuously - fold ma, ma, + 0 ma to ma to ma to ma I AN = Output circuit full - scale value V, V, + 10 V to V to V to V R ext min. [k ] U AN U AN [V] 5 ma = Output circuit full - scale value Tel , 00 Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in

3 Current limiter at R ext max. Voltage limiter at R ext = Approx. 13 V 8 Residual ripple in current Response time Power supply H AC/DC power pack (DC and Hz) Table 3 Nominal voltages and tolerances Nominal voltage U N V DC / AC V 1 DC / AC Power input Accuracy data (acc. to DIN/IEC 770) Basic accuracy Reference conditions Ambient temperature Power supply Approx. 1.1 x I for current AN < 0.5% p.p. < 50 ms Tolerance DC % AC + 15% < 1.6 W resp. < 3.4 VA Limit error + 0. % Including linearity and reproducibility errors 0 3 C + K 4 V DC + 10% & 30 V AC + 10% Installation Data Housing Material of housing Montage Position of use Terminals Permissible vibrations g acc. to EN Shock Weight Housing S 17 See section "Dimensional drawings" for dimensions L e x a n 4 0 ( p o l y c a r b o n a t e ) flammability class V-0 acc. to UL 4, self-extinguishing, non-dripping, free of halogen For snapping onto top - hat rail (35 x 15 mm or 35 x 7.5mm) acc. to EN 50 0 OR Directly onto a wall or panel using the pull - out screw hole brackets Any DIN / VDE 060 Screw terminals with wire guards, for light PVC wiring and max. x 0.75mm or 1 x.5 mm 3 x 50 g 3 shocks each in 6 directions acc. to EN Approx. 0. kg Output burden Influencing factors Temperature Current 0.5 R ext max. Voltage R min. ext < + 0.1% per 10 K Electrical insulation All circuit (measuring inputs / measuring s / power supply) are electrically insulated Burden influence <+ 0.1% for current <+ 0.% for voltage if Rext < Rext min. 1 For power supplies >15 V, the auxiliary circuit should include an external fuse with a rating < 0 A DC. Regulations Electromagnetic compatibility The standards DIN EN & DIN EN are observed Longtime drift Switch-on drift < + 0.3% / 1 months < + 0.% Protection (acc. to IEC 5 resp. EN 60 5) Housing IP 40 Terminals IP0 Common and transverse mode influence Output + or connected to ground < + 0.% < + 0.% Electrical standards Acc. to IEC 1010 resp. EN Operating voltages Contamination level < 300 V between all insulated circuits Tel , 00 Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in

4 Overvoltage category acc. to IEC 664 Double insulation Power supply versus all other circuits Measuring input versus measuring Test voltage III for power supply II for measuring input and measuring Power supply all 3.7 kv, 50 Hz, 1 min. Measuring inputs versus measuring s.3 kv, 50 Hz, 1 min. Measuring inputs 1 versus measuring inputs.3 kv, 50 Hz, 1 min. Measuring s 1 versus measuring s.3 kv, 50 Hz, 1 min. Environmental conditions Climatic rating Commissioning temperature 0 10 to + 55 C Operating temperature 5 to C Storage temperature Annual mean relative humidity < 75% variants Climate class 3 acc. to VDI/VDE to C 5 standard input and combinations selected by soldered jumpers User - specific input and / or ranges Isolating amplifier with one input two electrically insulated s. Power supply V DC / AC or V DC / AC please request our data sheet TV Le for single - channels versions. Configuration 1. Standard input ranges Soldered jumpers are provided for the coarse setting of the input ranges and the fine adjustment is accomplished using the potentiometers "ero" and "Span". 100 must be added to the designations of the soldered jumpers in the table for channel 1 and 00 for channel. (Example Input range for input 1 and input = ma Jumpers 1, 5, 6 and 11 must be inserted for this range. The corresponding jumpers for channels 1 are B 101, B 105, B 106 and B 111. The corresponding jumpers for channels are B 01, B 05, B 06 and B 11). Current [ma] Soldered jumpers Voltage [V] Soldered jumpers ,, 10, , 3 7, 10, , 8, 10, , 3 8, , 8,, , 4, 10, , 7, 8,, , 4 7, 10, , 7, 8, 10, , 4 8, , 8,, , 5 6, 7, 8, 10, , , 5 10, , , 5 6, , , 4 8, 10, 11 1, , 10, 11 1, , 4 6, 1, , 8,, 10 1, , 5 6, 7, 10, 11 1, , 7, 10, 11 1, , 5 6, 7, 8, 11 1, , 7, 8, 11 1, , 3 8, 11 13, 14, , 8,, 11 13, 14, , 3 7, 13, 14, , 7,, 10 13, 14, , 4 7, 10, 11 13, 14, , 8, 10, 11 13, 14, , 4 8, 11 13, 14, , 8,, 11 13, 14, , 4 6, 13, 14, , 8,, 10 13, 14, , 5 10, 11 13, 14, , 11 13, 14, , 5 6, 11 13, 14, , 11 13, 14, , 5 6, 7 13, 14, , 14, 16 Tel , 00 Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in

5 . Standard ranges Soldered jumpers are provided for the coarse setting of the ranges and the fine adjustment is accomplished using the potentiometers "ero" and "Span". Current ma Soldered jumpers Channel 1 Channel Voltage V Soldered jumpers Channel 1 Channel B 10 B B 10 B B 1 B B 13 B 3 Standard accessories 1. Operating instructions. Pull out clamp S 17 ( For operating the housing ) 3. Front Labels B 11 B B 11 B 1 10 B 1 B B 13 B B 1 B B 13 B 3 3. Specific user ranges Units that have been configured for a specific user range cannot be subsequently reconfigured. B101 B10 B103 B104 B105 B106 B107 B108 B10 B110 B111 B11 B113 B114 B115 B116 B117 B1 B1 B0 B1 B13 B14 B15 B16 B17 B13 B06 B07 B08 B0 B10 B11 B01 B0 B03 B04 B05 Span ero Span 1 ero 1 B3 B B11 B10 Fig.. Position of the soldered jumpers B and the potentiometers Span and ero. Tel , 00 Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in

6 Dimensional Drawings Electrical connections Front Span Fig. 3. RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail (35 x 15 mm or 35 x 7.5 mm, acc to EN 50 0). ero RISHDucer TV 808 Span 1 ero RISHABH RISHDucer TV 808 ON Green LED for device standing by ON Fig. 4. RISH Ducer TV 808 in housing S 17, screw hole mounting brackets pulled out. Without transparent cover With transparent cover I1+ U1+ I+ U E1 E A1 A H E1 = Input 1 E = Input A1 = Output 1 A = Output H = Power supply Tel , 00 Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in

7 Table No- 4 Ordering Information DESCRIPTION MARKING 1. Mechanical Design Housing S17 for rail and wall mounting Number of channels ) channels 3. Version / power supply 1) Standard, ) Standard, 4. Function ) inputs, electrically insulated s 3) 1 inputs, electrically insulated s 5. Input signal, input 1 ) Input [V] ) Input [ma] Line [V] to start value > 0 to < 50% final value or span 0.06 to 40 V between - 40 and 40 V ( also bipolar asymmetrical ) Line [ma] to start value > 0 to < 50% final value or span 0.1 to 40 ma between - 40 and 40 ma ( also bipolar asymmetrical ) 6. Output signal, 1 ) Output [V] ) Output [ma] Line [V] to to to Line [ma] to to to or span 0.1 to 40 ma between - 40 and 40 ma ( also bipolar asymmetrical ) 7. Input signal, input 0) Without input ) Without input [V] ) Input [ma] Ranges possibles see input 1 8. Output signal, ) Out [V] ) Output [ma] Ranges possibles see 1 Possible special versions, e.g. increased climatic rating on inquiry. (see also Table 1 and Standard versions ) V DC/AC V DC/AC Tel , 00 Fax India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in 1 3 0

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar SINEAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. ) is to electrically insulate input and

More information

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output

More information

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate

More information

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out. Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta

More information

SINEAX B 811 Power Pack with additional Functions

SINEAX B 811 Power Pack with additional Functions SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers

More information

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage Application The transducers SINEAX I 503/U 504 (Figs. 1 and 2) are designed to convert a sinusoidal AC current or voltage into a load independent DC signal proportional to the measured value. This output

More information

SINEAX U 553 Transducer for AC Voltage

SINEAX U 553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics RISH Ducer E13 Transducer For c Current Or c Voltage With Different Characteristics Data Sheet For Measurement of C Current or C Voltage Fig. 1. RISH Ducer E13 clipped onto a top - hat rail. Fig. 2. RISH

More information

SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate

More information

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically

More information

RISH Ducer E13 3 channel transducer for AC current and voltage

RISH Ducer E13 3 channel transducer for AC current and voltage RISH Ducer E13 3 channel transducer for C current and voltage The RISH Ducer E13 ( Fig. 1) converts 3 sine wave C current or C voltage into 3 output signals that can serve several receiving instruments

More information

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SINEAX TV809, 1 channel Programmable Isolating Amplifier For electrically insulating, ampliflying and converting DC signals 0102 II (1) Ga II (1) Da Application The purpose of the isolating amplifi er SINEAX TV809 (Fig. 1) is to electrically insulate input and

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

SINEAX I 552 Transducer for AC current

SINEAX I 552 Transducer for AC current SNEAX 55 With power supply RMS value measurement, with measuring ranges Carrying rail housing P/0 Application he transducer SNEAX 55 (Fig. ) converts a sinusoidal or a distorted AC current into a load

More information

SINEAX G 536 Phase Angle or Power Factor Transducer

SINEAX G 536 Phase Angle or Power Factor Transducer SIEAX G Carrying rail housing P/0 Application The transducer SIEAX G (Fig. ) measures the phase angle or power factor between current and voltage of a single or -phase balanced network having a sine wave

More information

EMBSIN 281 G Power factor transducer

EMBSIN 281 G Power factor transducer EMBSI 8 G Carrying rail housing MBS/SP Application The transducer EMBSI 8 G (Fig. ) measures the power factor between current and voltage of a single or 3-phase balanced network having a sine wave form.

More information

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS RISH Ducer 5 TRNSDUCR FOR C CURRNT OR C VOLTG WITH DIFFRNT CHRCTRISTICS The RISH Ducer 5 transducer (Fig and ) is used where a sine-wave C current or voltage is to be converted into a DC signal proportional

More information

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar for electrically insulating, amplifying and converting DC signals 0102 II (1) G pplication The purpose of the isolating amplifi er SIRX T 808 (Fig. 1) is to electrically insulate input and output signals,

More information

SINEAX G 537 Transducer for Phase Angle Difference

SINEAX G 537 Transducer for Phase Angle Difference Carrying rail housing P/0 pplication The transducer SINX G 5 (Fig. ) converts the phase angle difference of two synchronised supplies into a load independent DC current or a load independent DC voltage

More information

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 002 II () G pplication The purpose of the isolating amplifi er SIRX TV 808 (Fig. ) is to electrically insulate input

More information

Theta 20A / 20V. Technical Data Sheet. Special Features

Theta 20A / 20V. Technical Data Sheet. Special Features Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in

More information

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits for s or voltages, temperature sensors, remote sensors or potentiometers pplication The universal transmitter RISH Ducer V 604 (Figures 1 and 2) convert the input variable a or voltage, or a signal from

More information

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) Tranducers for alternating current/voltage n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) and input current range (for CIP-I) n Available in single or dual output type

More information

Plug-in module SIRAX TI 807 Passive DC signal isolator

Plug-in module SIRAX TI 807 Passive DC signal isolator without power supply, x- and non-x version 0102 II (1) resp. II (2) pplication The signal isolator SIRX TI 807 (Fig. 1) serves to electrically insulate the analogue DC signal in the range 0 20 m which

More information

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New) XUA1 AC Voltage and phase balance relay (August 1996) Manual XUA1 (Revision New) Woodward Manual XUA1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

Theta Hz. Technical Data Sheet. Special Features

Theta Hz. Technical Data Sheet. Special Features Technical Data Sheet Theta Hz Theta Hz the transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent

More information

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs Plug-in module, or channels Application The programmable transmitter (Fig. ) is designed for measuring temperature in combination with thermocouples or resistance thermometers. Thermocouple non-linearities

More information

RISH Ducer IXX / VXX Series (TRMS/Average) Transducer for AC current / AC Voltage (Single or Dual Output)

RISH Ducer IXX / VXX Series (TRMS/Average) Transducer for AC current / AC Voltage (Single or Dual Output) RISH Ducer IXX / VXX Series (TRMS/verage) Transducer for C current / C Voltage (Single or Dual Output) Data Sheet Transducer for C Current and C Voltage Fig. 1. RISH Ducer I11 in housing E16 clipped onto

More information

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits SINEAX VC 603, Programmable for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Figs. 1 and 2) converts the input variable a

More information

SINEAX V 604 Programmable universal transmitter

SINEAX V 604 Programmable universal transmitter for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The universal transmitter SINEAX V 604 (Figures 1 and 2) converts the input variable a DC current

More information

RISH Ducer V604 Programmable universal transmitter

RISH Ducer V604 Programmable universal transmitter RISH Ducer V64 Programmable universal transmitter Data Sheet Programmable Universal Transmitter RISH Ducer V64 RISH Ducer V64 Fig. Transmitter RISH Ducer V64 in housing S7 clipped on a p-hat rail Fig.

More information

XUA1 - AC Voltage and phase balance relay

XUA1 - AC Voltage and phase balance relay XUA1 - AC Voltage and phase balance relay Contents 1. Applications and features 2. Design 3. Function 3.1 Voltage supervision 3.2 Unbalanced voltage supervision 4. Operation and settings 4.1 Setting of

More information

RISH CON SI-102 (Dual out put DC Isolator)

RISH CON SI-102 (Dual out put DC Isolator) RISH CON SI-2 (Dual out put DC Isolator) Data sheet Isolating Amplier Application : The purpose of the RISH CON SI-2 is to electrically isolate input, outputs and power supply. The isolator fullls all

More information

SINEAX / EURAX 2I1 Passive DC signal isolator

SINEAX / EURAX 2I1 Passive DC signal isolator SINEAX / EURAX I without power supply 0 II () G resp. II () G Application The DC signal isolator SINEAX/EURAX I (Figs. and ) serve to isolate load-independent DC current signals. It suppressed noise voltages

More information

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New) XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided

More information

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions Installation and start up instructions TAS-311DG Selectable AC transducer Voltage, current, frequency or phase angle transducer Supply voltage up to 690V DEIF A/S Configuration via PC-interface possible

More information

Switching power supplies CP range, Linear power supplies CP-L range. Content

Switching power supplies CP range, Linear power supplies CP-L range. Content CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional

More information

Measuring current transformers of the W, W series

Measuring current transformers of the W, W series Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000

More information

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C) XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by

More information

For Immediate Delivery call KMParts.com at (866)

For Immediate Delivery call KMParts.com at (866) Contents 9/1 Page Description SN4 switched-mode power supply units 9/2 GW4 power supply units 9/3 GD4 power supply units 9/4 Basic Units, Accessories 9/5 Technical data 9/6 Dimensions 9/12 9/2 Description

More information

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+) Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New) XI1-I Time overcurrent relay (Januar 2007) Manual XI1-I (Revision New) Woodward Manual XI1-I GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000 High-Voltage Isolation Amplifiers / Shunt Isolators VariTrans P 29000 Compact high-voltage isolators with safe galvanic isolation, VariPower broad-range power supply and genuine calibrated range selection.

More information

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004 Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay

More information

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs

More information

Coupling Relays and Converters

Coupling Relays and Converters Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard

More information

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New) XU2-AC AC voltage relay (Februar 1997) Manual XU2-AC (Revision New) Woodward Manual XU2-AC GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description. Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed

More information

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101

More information

DATA SHEET Selectable AC transducer TAS-311DG

DATA SHEET Selectable AC transducer TAS-311DG DATA SHEET Selectable AC transducer Measuring on AC networks Class 0.5 (IEC688) measurement Supply/measur. voltage up to 690 V Easy configuration via PC interface possible DEIF A/S Frisenborgvej 33 DK-7800

More information

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

Installation / Monitoring Technique

Installation / Monitoring Technique Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

LINAX 4000L Continuous-line recorder

LINAX 4000L Continuous-line recorder -48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged

More information

Analog signal converters CC range

Analog signal converters CC range Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally

More information

VariTrans P D1 TRMS

VariTrans P D1 TRMS Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings VariTrans P 41000 D1 TRMS VariTrans P 41000 TRMS AC/DC High-Voltage Transmitters With True

More information

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage

More information

KINAX SR 719 Programmable Transmitter for Position Feedback

KINAX SR 719 Programmable Transmitter for Position Feedback Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 719 (Figs. 1 and 2) is used to measure and transmit linear displacement (stroke) on various types of

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

CP-T range Benefits and advantages

CP-T range Benefits and advantages Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Primary switched-mode power supply units In standard machine production, the requirements for a power supply unit are mostly specified in advance. Here, the TRIO POWER power supply units are suitable which

More information

MBS AG EMBSIN 120 UV. without auxiliary voltage supply housing for 35 mm DIN rail mounting

MBS AG EMBSIN 120 UV. without auxiliary voltage supply housing for 35 mm DIN rail mounting EMBSIN 120 UV Measuring transducers for AC current : Sinus-shaped alternating voltage (0 20 A or 0 500 V) : Unipolar output signal measuring principle: Rectifier mean value measurement process economic

More information

CP-T range Product group picture

CP-T range Product group picture Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details

More information

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS AC/DC high-voltage isolators for true rms measurement Input currents ranging from Iin = 100 ma AC to Iin = 5 A AC The Task In electrical systems, alternating currents from 100 ma to 5 A need to be recorded,

More information

XF2 Frequency Relay. Manual XF2 (Revision A)

XF2 Frequency Relay. Manual XF2 (Revision A) XF2 Frequency Relay Manual XF2 (Revision A) Woodward Manual XF2 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by Woodward Governor

More information

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C. ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task

More information

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω

More information

SINEAX V 604s Programmable multifunctional transmitter

SINEAX V 604s Programmable multifunctional transmitter SINEAX V 60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers 00 SINEAX V60s is a multifunctional transmitter f top-hat rail assembly with the following main characteristics:

More information

VariTrans P V. Safe and Sound.

VariTrans P V. Safe and Sound. 1000 V. Safe and Sound. VariTrans P 29000 Compact high-voltage isolation amplifiers with safe galvanic isolation, VariPower broad-range power supply and genuine calibrated range selection. Isolation Amplifiers

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New) XP2-R Power and reverse power relay (January 2006) Manual XP2-R (Revision New) Woodward Manual XP2-R GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2 Data Sheet 066.8e Transducers for Active and Reactive Power EW 2.2 DGW 2.2 VGW 2.2 DUW 2.2 VUW 2.2 Application The E/DG/VG/DU/VU W 2.2 power transducers convert all forms of active and reactive power polarity

More information

02/11/2015

02/11/2015 Emergency stop and safety guard monitoring 1 channel KNAC3-YS Part number 85103035 "Emergency stop" & "Gate monitoring" functions Single channel operation Security with redundancy and feedback circuit

More information

Measuring current transformers of the W AB(P) series

Measuring current transformers of the W AB(P) series Measuring current transformers of the W AB(P) series W-AB(P)_D00074_02_D_XXEN/07.2017 Measuring current transformers of the W AB(P) series Product description Measuring current transformers of the W -AB

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Output of three-phase motors at 50 Hz and 400 V

Output of three-phase motors at 50 Hz and 400 V RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements

More information

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv When temperatures are to be measured using Pt100 resistance thermometers in high-voltage environments, standard temperature transmitters

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

KINAX 2W2 Programmable Transmitter for Angular Position

KINAX 2W2 Programmable Transmitter for Angular Position Application The KINAX 2W2 (Figs. 2 and 3) converts the angular position of a shaft into a load independent direct current signal, proportional to the angular position. The unit is contact free and has

More information

Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN

Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN Electronic alarm signalling unit TES 20 ENA117.01 EN for temperature and standard signals Universal alarm signalling unit (constructional width 4 T) for Temperature (temperature monitor) with Pt 100 IEC

More information

XP2-R Power and Reverse Power Relay

XP2-R Power and Reverse Power Relay XP2-R Power and Reverse Power Relay Manual XP2-R (Revision C) Woodward Manual XP2-RE Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR The T-W or T-V power transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watts)

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters EA12 EA19 EA17 EA16 EB16 APPLICATION EA16, EB16, EA17, EA19 and EA12 moving-iron meters are intended for measuring AC voltage or

More information

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS High-Voltage Isolation Amplifiers / Shunt Isolators AC/DC high-voltage isolators for true rms measurement Input voltages up to Vin = 3600 V AC The Task In electrical systems, alternating voltages from

More information

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24... P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector

More information

EURAX UI 505, Combined Transducer for AC current and AC voltage

EURAX UI 505, Combined Transducer for AC current and AC voltage Plug-in module in Euro-format Application The transducers EURAX UI 505 (Fig. 1) are intended to simultaneous converts of up to 3 sinusoidal AC currents or voltages. Output signals available are load-independent

More information

For non-electrical quantities

For non-electrical quantities Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data

More information