SINEAX G 536 Phase Angle or Power Factor Transducer
|
|
- Allison Riley
- 5 years ago
- Views:
Transcription
1 SIEAX G Carrying rail housing P/0 Application The transducer SIEAX G (Fig. ) measures the phase angle or power factor between current and voltage of a single or -phase balanced network having a sine wave form. The output signal, in the form of a load independent DC current or voltage, is proportional to the phase angle resp. power factor between the measured quantities current and voltage. The transducer fulfi ls all the important requirements and regulations concerning electromagnetic compatibility EMV and Safety (IEC 00 resp. E 00). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 00. Fig.. Transducer SIEAX G in housing P/0 clipped onto a top-hat rail. Measuring input Features / Benefits Measuring input: Sine, rectangular or distorted wave forms of input quantities with dominant fundamental wave Measured variables Phase angle or power factor ominal input current ominal input voltage 0. to A 0 to 0 V Measuring range limits Min. span 0 el Max. span 0 el Measuring output: Unipolar, bipolar or live zero output variables Measuring principle: Measurement of the zero crossing interval AC/DC power supply / Universal Standard as marine version per Lloyd s Register of Shipping Examples of measuring ranges with ϕ-linear output [ el] inductive (lag) capacitive (lead) inductive (lag) capacitive (lead) Motor (incoming) Meas. range: 0 0 Messbereich: -0 0 Measuring range: -0 0 Measuring range: -0 0 (clear indication of ) Examples of measuring ranges with cosϕ-linear output [cosϕ] Technical data General Measured quantity: Measuring principle: between current and voltage Measurement of the zero crossing interval inductive (lag) capacitive (lead) inductive (lag) capacitive (lead) ominal frequency f : Motor (incoming) 0.-cap- -ind cap--ind-0 0.-cap--ind ind 0 cap ind 0 cap -0. / 00 Hz Camille Bauer Data sheet G Le 0.0
2 SIEAX G ominal input voltage U : Response sensitivity: ominal input current I : Response sensitivity: Own consumption: Overload capacity: Input variables I.U umber of applications 0 0 V (max. 0 V with power supply from voltage measuring input) 0 0% U 0. to.0 A < % I < 0. VA per current path U. ma per voltage path Duration of one application. x I continuously 0 x I 0 s 00 s. x U continuously x U 0 s 0 s Interval between two successive applications But max. V with power supply from voltage measurement Measuring output Load-independent DC current: Burden voltage: Load-independent DC voltage: Load capacity: Voltage limit under R ext = : Current limit under overload: Residual ripple in output current: ominal value of response time: Other ranges: Output characteristic.ae AE AA = 0 A EA unipolar EE.EE 0.EA E 0 to 0 0 ma resp. live-zero to 0 ma ± to ± 0 ma + V, resp. V 0 to 0 0 V resp. live-zero 0. to 0 V ± to ± 0 V Max. ma V Approx. 0 ma < 0.% p.p. periods of the nominal frequency, or periods of the nominal frequency.ae 0.AA AE AA = 0.AE 0 A EA live-zero EE.EE 0.EA E.AE 0.AA AE 0 A.EA 0.EE EA AA 0.AA.AE bipolar EE.EE 0.EA Accuracy (acc. to E 0 ) E Legend: E = Input EA = Input start value EE = Input end value A = Output AA = Output start value AE = Output end value Reference value: Δϕ = 0 resp. Δcosϕ = 0. Basic accuracy: Class 0. Reference conditions Ambient temperature 0 C Input current 0.. I Input voltage 0.. U Frequency f ± 0% Wave forms Sine wave Power supply At nominal range Output burden Δ R ext max. Additional errors (maxima): Voltage infl uence between 0. and. U ± 0.% Current infl uence between 0. and. I ± 0.% between 0. and. I ± 0.% Safety Protection class: II (protection isolated, E 00) Housing protection: IP 0, housing (test wire, E 0 ) IP 0, terminals (test fi nger, E 0 ) Contamination level: Overvoltage category: III Rated insulation voltage (against earth): 0 V resp. 00 V, inputs 0 V, power supply 0 V, output Test voltage: 0 Hz, min. acc. to E resp. 0 V, inputs versus all other circuits as well as outer surface Data sheet G Le 0.0 Camille Bauer
3 SIEAX G Test voltage (continuation): Power supply 0 V, input circuits versus each other 00 V, power supply versus output as well as outer surface 0 V, output versus outer surface AC/DC power pack (DC or 0 00 Hz) Table : Rated voltages and permissible variations Rated voltage Tolerance 0 V DC, AC DC + % 0 V DC, AC AC ± % or Power supply from voltage measuring input: 0 V AC or 0 V AC Option: Connect to the low tension to terminals and V AC or 0 V DC Power consumption: Approx. W resp. VA Installation data Mechanical design: Housing P/0 Material of housing: Lexan 0 (polycarbonate), fl ammability Class V-0 acc. to UL, self-extinguishing, non-dripping, free of halogen Mounting: For rail mounting Mounting position: Any Weight: Approx. 0. kg Permissible cross section of the connection leads: Environmental conditions.0 mm single wire or x. mm fi ne wire Operating temperature: 0 to + C Storage temperature: 0 to + 0 C Relative humidity of annual mean: % Altitude: 000 m max. Indoor use statement! Ambient tests E 0 0--: Acceleration: Frequency range: umber of cycles: E 0 0--: Vibration ± g Hz, rate of frequency sweep: octave/minute 0, in each of the three axes Shock Acceleration: 0 shocks each in directions E 0 0--/-/-: Cold, dry heat, damp heat IEC 000--/-/-/-/- E 0: Electromagnetic compatibility Germanischer Lloyd Type approval certifi cate: Ambient category: Vibration: o. - HH C 0. g Connecting terminals Connection element: Screw-type terminals with indirect wire pressure Table : Specification and ordering information Description *Blocking code no-go with blocking code Article o./ Feature SIEAX G Order Code - xxxx xxxx xx Features, Selection. Mechanical design Housing P/0 for rail mounting. Measuring mode For phase angle (ϕ-linear) A For power factor (cosϕ-linear) B Camille Bauer Data sheet G Le 0.0
4 SIEAX G Description *Blocking code no-go with blocking code Article o./ Feature SIEAX G Order Code - xxxx xxxx xx Features, Selection. Application Single-phase AC U: & I: or -wire -phase balanced load U: & I: or -wire -phase balanced load U: & I: or -wire -phase balanced load U: & I: or -wire -phase balanced load U: & I: or -wire -phase balanced load U: & I: or -wire -phase balanced load U: & I: or -wire -phase balanced load A U: & I: or -wire -phase balanced load B U: & I: or -wire -phase balanced load C. ominal input frequency 0 Hz 0 Hz on-standard [Hz] 0 to 00 Hz With power supply from measuring input min. 0 Hz. ominal input voltage U = 00 V C U = 0 V C U = 00 V D on-standard [V] 0 to 0 V With power supply from measuring input min. V, max. 0 V, see feature, lines and -phase system: Input voltage = phase to phase voltage. ominal input current A A on-standard [A] 0. to.0 A. Measuring range Phase angle el B cosϕ 0. cap ind 0. A on-standard [ el] or [cosϕ] Measuring range within el or ind 0 cap ind 0 cap, but clear indication only to 0 + el Measuring span 0 el. Output signal 0 0 ma 0 ma on-standard 0.00 to 0 < 0, [ma] to (symmetrical) to < ( 0) (AA / AE = / ) 0 0 V A on-standard 0.00 to 0 < 0, [V] to (symmetrical) Z 0. to 0 (AA / AE = / ) AA = Output start value, AE = Output end value Data sheet G Le 0.0 Camille Bauer
5 SIEAX G Description *Blocking code no-go with blocking code Article o./ Feature SIEAX G Order Code - xxxx xxxx xx Features, Selection. Power supply 0 V DC, AC 0 V DC, AC Internal from measuring input ( 0 V AC) C Internal from measuring input ( 0 V AC) CD Connect to the low tension V AC / 0 V DC 0. Response time periods of the input frequency (standard) periods of the input frequency periods of the input frequency periods of the input frequency * Lines with letter(s) under no-go cannot be combined with preceding lines having the same letter under SCODE. Application notes Current connection in phase Voltage connection between & & & & & & Vector diagrams Current connection in phase Voltage connection between L & & & L & Vector diagrams I U Camille Bauer Data sheet G Le 0.0
6 SIEAX G Electrical connections ( )(+) = Measuring input = Measuring output = Power supply U I ( )(+) U I U I Fig.. Power supply connected to terminals and. Fig.. Power supply internal from measuring input, without separated power supply. Fig.. Power supply connected to the low tension terminal side and. Measuring inputs Application Terminal allocation Application Terminal allocation single-phase AC network // or -wire -phase network U: & I: or -wire -phase network U: & I: or -wire -phase network U: & I: or -wire -phase network U: & I: or -wire -phase network U: & I: or -wire -phase network U: & I: or -wire -phase network U: & I: Data sheet G Le 0.0 Camille Bauer
7 SIEAX G Measuring inputs Application Terminal allocation Application Terminal allocation or -wire -phase network U: & I: or -wire -phase network U: & I: Dimensional drawing. Standard accessories Operating instructions in three languages: German, French, English Fig.. Housing P/0 clipped onto a top-hat rail ( x or x. mm, acc. to E 0 0). Rely on us. Camille Bauer Ltd. Aargauerstrasse CH-0 Wohlen / Switzerland Phone: + Fax: + info@camillebauer.com Subject to change without notice Edition 0.0 Data sheet G Le
EMBSIN 281 G Power factor transducer
EMBSI 8 G Carrying rail housing MBS/SP Application The transducer EMBSI 8 G (Fig. ) measures the power factor between current and voltage of a single or 3-phase balanced network having a sine wave form.
More informationSINEAX G 537 Transducer for Phase Angle Difference
Carrying rail housing P/0 pplication The transducer SINX G 5 (Fig. ) converts the phase angle difference of two synchronised supplies into a load independent DC current or a load independent DC voltage
More informationSINEAX U 553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
More informationSINEAX I 552 Transducer for AC current
SNEAX 55 With power supply RMS value measurement, with measuring ranges Carrying rail housing P/0 Application he transducer SNEAX 55 (Fig. ) converts a sinusoidal or a distorted AC current into a load
More informationSINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar
SINEAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. ) is to electrically insulate input and
More informationSINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar
For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output
More informationSINEAX TV809, 1 channel Programmable Isolating Amplifier
For electrically insulating, ampliflying and converting DC signals 0102 II (1) Ga II (1) Da Application The purpose of the isolating amplifi er SINEAX TV809 (Fig. 1) is to electrically insulate input and
More informationSINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex
for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate
More informationSINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage
Application The transducers SINEAX I 503/U 504 (Figs. 1 and 2) are designed to convert a sinusoidal AC current or voltage into a load independent DC signal proportional to the measured value. This output
More informationSINEAX B 811 Power Pack with additional Functions
SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers
More informationPlug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar
for electrically insulating, amplifying and converting DC signals 0102 II (1) G pplication The purpose of the isolating amplifi er SIRX T 808 (Fig. 1) is to electrically insulate input and output signals,
More informationSINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator
SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically
More informationPlug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs
Plug-in module, or channels Application The programmable transmitter (Fig. ) is designed for measuring temperature in combination with thermocouples or resistance thermometers. Thermocouple non-linearities
More informationSINEAX TI 807 Passive DC signal isolator
without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate
More informationTheta 20A / 20V. Technical Data Sheet. Special Features
Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in
More informationRISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar
Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power
More informationSINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs
SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.
More informationKINAX WT 717 Programmable Transmitter for Angular Position
Ruggedized version Application The KINAX WT 717 (Fig. 1) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact
More informationKINAX 2W2 Programmable Transmitter for Angular Position
Application The KINAX 2W2 (Figs. 2 and 3) converts the angular position of a shaft into a load independent direct current signal, proportional to the angular position. The unit is contact free and has
More informationPlug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex
for electrically insulating, amplifying and converting DC signals, also designed for FSK 002 II () G pplication The purpose of the isolating amplifi er SIRX TV 808 (Fig. ) is to electrically insulate input
More informationn True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)
Tranducers for alternating current/voltage n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) and input current range (for CIP-I) n Available in single or dual output type
More informationTheta Hz. Technical Data Sheet. Special Features
Technical Data Sheet Theta Hz Theta Hz the transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent
More informationKINAX SR 719 Programmable Transmitter for Position Feedback
Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 719 (Figs. 1 and 2) is used to measure and transmit linear displacement (stroke) on various types of
More informationPlug-in module SIRAX TI 807 Passive DC signal isolator
without power supply, x- and non-x version 0102 II (1) resp. II (2) pplication The signal isolator SIRX TI 807 (Fig. 1) serves to electrically insulate the analogue DC signal in the range 0 20 m which
More informationRISH Ducer E13 3 channel transducer for AC current and voltage
RISH Ducer E13 3 channel transducer for C current and voltage The RISH Ducer E13 ( Fig. 1) converts 3 sine wave C current or C voltage into 3 output signals that can serve several receiving instruments
More informationTheta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.
Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta
More informationRISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics
RISH Ducer E13 Transducer For c Current Or c Voltage With Different Characteristics Data Sheet For Measurement of C Current or C Voltage Fig. 1. RISH Ducer E13 clipped onto a top - hat rail. Fig. 2. RISH
More informationSINEAX V 604s Programmable multifunctional transmitter
SINEAX V 60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers 00 SINEAX V60s is a multifunctional transmitter f top-hat rail assembly with the following main characteristics:
More informationEURAX UI 505, Combined Transducer for AC current and AC voltage
Plug-in module in Euro-format Application The transducers EURAX UI 505 (Fig. 1) are intended to simultaneous converts of up to 3 sinusoidal AC currents or voltages. Output signals available are load-independent
More informationSINEAX / EURAX 2I1 Passive DC signal isolator
SINEAX / EURAX I without power supply 0 II () G resp. II () G Application The DC signal isolator SINEAX/EURAX I (Figs. and ) serve to isolate load-independent DC current signals. It suppressed noise voltages
More informationRISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS
RISH Ducer 5 TRNSDUCR FOR C CURRNT OR C VOLTG WITH DIFFRNT CHRCTRISTICS The RISH Ducer 5 transducer (Fig and ) is used where a sine-wave C current or voltage is to be converted into a DC signal proportional
More informationKINAX WT 707 Transmitter for angular position
Ruggedized version pplication The KINX WT 707 (Figs. 1 to 6) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact
More informationKINAX 3W2 Transmitter for angular position
KINX 3W2 For installation KINX 3W2 is a compact transmitter for angular position for installation in devices and apparatus. Due to its unique capacitive measuring principle, it acquires the angular position
More informationZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer
nalogue Meters With Moving - Iron Movement pplication IEGER PR-P The iegler PR-P transducer is used to measure and convert active, reactive, apparent power, Phase angle & Power Factor of a Single-phase
More informationSINEAX V604s Programmable multifunctional transmitter
SINAX V60s for direct currents, direct voltages, temperature sensors, teletransmitters or potentiometers SINAX V60s is a multifunctional transmitter for tophat rail assembly with the following main characteristics:
More informationRudder or propeller angular position transmitter KINAX WT720
Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to
More informationSUBJECT TO CHANGE WITHOUT NOTICE
TRNSUCERS & ISTRS Theta 30P www.sifamtinsley.co.uk TSHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders igital Panel Meters Current Transformers
More informationRISH Ducer IXX / VXX Series (TRMS/Average) Transducer for AC current / AC Voltage (Single or Dual Output)
RISH Ducer IXX / VXX Series (TRMS/verage) Transducer for C current / C Voltage (Single or Dual Output) Data Sheet Transducer for C Current and C Voltage Fig. 1. RISH Ducer I11 in housing E16 clipped onto
More informationfor DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits
SINEAX VC 603, Programmable for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Figs. 1 and 2) converts the input variable a
More informationPOWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL
POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK PP, PP and PB ISO 900 C E R T Y F I K A T 4 mm SERVICE MANUAL Contents Page. APPLICATION... 2. BASIC REQUIREMENTS.... TRANSDUCER SET... 4 4. TECHNICAL
More informationEA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters
EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters EA12 EA19 EA17 EA16 EB16 APPLICATION EA16, EB16, EA17, EA19 and EA12 moving-iron meters are intended for measuring AC voltage or
More informationPOWER \ PHASE ANGLE \ POWER FACTOR TRANSDUCER RISH
Operating Manual POWER \ PHASE ANGLE \ POWER FACTOR TRANSDUCER RISH CON - P ON O/P1 O/P2 COM RISH CON - P IC :15001143 Rev.B - 17/12/13 POWER \ PHASE ANGLE \ POWER FACTOR TRANSDUCER POWER \ PHASE ANGLE
More informationSINEAX VC 603, Programmable combined transmitter/alarm unit
for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Fig. 1) converts the input variable a DC current or voltage, or a signal
More informationSINEAX V 604 Programmable universal transmitter
for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The universal transmitter SINEAX V 604 (Figures 1 and 2) converts the input variable a DC current
More informationXUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)
XUA1 AC Voltage and phase balance relay (August 1996) Manual XUA1 (Revision New) Woodward Manual XUA1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
More informationMeasuring Transducer MT4xx series Programmable AC Current Transducer MT418
Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz
More informationHG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS
20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,
More information12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices
BETA Measuring /2 Product overview /3 7KT1 14, 7KT1 53 E-counters /9 7KT1 11, 7KT1 digital measuring devices /11 7KT1 0 analog measuring devices / 7KT5 8 time and pulse counters /14 7KT5 5, 7KT5 6 time
More informationTRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs
More informationXP2-R Power and Reverse Power Relay
XP2-R Power and Reverse Power Relay Manual XP2-R (Revision C) Woodward Manual XP2-RE Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward
More informationProgrammable AC Voltage Transducer MT416
Programmable AC Voltage Transducer MT416 RMS AC voltage or frequency measurements Voltage auto measurements up to 600 V L-N Frequency measurement 16 400 Hz AC or universal wide auiliary power 24 300 Vdc,
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationDEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions
Installation and start up instructions TAS-311DG Selectable AC transducer Voltage, current, frequency or phase angle transducer Supply voltage up to 690V DEIF A/S Configuration via PC-interface possible
More informationDATA SHEET Selectable AC transducer TAS-311DG
DATA SHEET Selectable AC transducer Measuring on AC networks Class 0.5 (IEC688) measurement Supply/measur. voltage up to 690 V Easy configuration via PC interface possible DEIF A/S Frisenborgvej 33 DK-7800
More informationData Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2
Data Sheet 066.8e Transducers for Active and Reactive Power EW 2.2 DGW 2.2 VGW 2.2 DUW 2.2 VUW 2.2 Application The E/DG/VG/DU/VU W 2.2 power transducers convert all forms of active and reactive power polarity
More informationPROGRAMMABLE TRANSDUCER OF DC CURRENT AND DC VOLTAGE SIGNALS P20H TYPE
PROGRAMMABLE TRANSDUCER OF DC CURRENT AND DC VOLTAGE SIGNALS P20H TYPE USER S MANUAL 1 2 Contents: 1. APPLICATION... 5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY... 6 4. INSTALLATION... 7 4.1. Fixing
More informationXP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)
XP2-R Power and reverse power relay (January 2006) Manual XP2-R (Revision New) Woodward Manual XP2-R GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
More informationCourtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)
Primary switched-mode power supply units In standard machine production, the requirements for a power supply unit are mostly specified in advance. Here, the TRIO POWER power supply units are suitable which
More informationXU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)
XU2-AC AC voltage relay (Februar 1997) Manual XU2-AC (Revision New) Woodward Manual XU2-AC GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
More informationPOINTAX 6000L2 Point Recorder
GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,
More informationProduct Guide. Transducers
x y Product Guide Transducers 800.U.001.01 P/Q f for AC Current or AC Voltage: A1U / V1U 2.2 also self-powered: AU / VU 2.0 for Active or Reactive Power in single phase systems: EW / EB 2.2 in balanced
More informationRelais und Automatisierungssysteme JUST IN TIME. with the. New Generation NGG. from Schleicher NGG CATALOGUE
JUST IN TIME with the New Generation NGG from Schleicher NGG CATALOGUE General information on the New Generation NGG Quality control 2 Norms, regulations, approvals 2 Housing system, conductor sizes 3
More informationMBS AG EMBSIN 120 UV. without auxiliary voltage supply housing for 35 mm DIN rail mounting
EMBSIN 120 UV Measuring transducers for AC current : Sinus-shaped alternating voltage (0 20 A or 0 500 V) : Unipolar output signal measuring principle: Rectifier mean value measurement process economic
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More informationProgrammable AC Current Transducer MT418
Programmable AC Current Transducer MT418 RMS AC current measurements Current auto range measurements up to 12 A Frequency measurement range 16 400 Hz AC or universal wide auiliary power supply range 24
More informationXUA1 - AC Voltage and phase balance relay
XUA1 - AC Voltage and phase balance relay Contents 1. Applications and features 2. Design 3. Function 3.1 Voltage supervision 3.2 Unbalanced voltage supervision 4. Operation and settings 4.1 Setting of
More informationLINAX 4000L Continuous-line recorder
-48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged
More informationSEPARATOR P20G TYPE USER S MANUAL
SEPARATOR P20G TYPE USER S MANUAL 1 2 Contents 1. APPLICATION... 5 2. SEPARATOR SET... 5 3. OPERATIONAL SAFETY... 6 4. FITTING... 7 4.1. Fixing Way... 7 4.2. External Connection Diagrams... 8 5. SERVICE...
More informationEMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.
Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationTRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type
TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External
More informationRISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:
Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More information3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/
3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging
More informationVariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.
ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More informationBtdin RCD Add-on modules 63A for MCBs 1,5 modules per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and
More informationType: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description
Type: EASY719 DA RC Article.: 274117 Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More information20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V
20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor
More informationFor Immediate Delivery call KMParts.com at (866)
Contents 9/1 Page Description SN4 switched-mode power supply units 9/2 GW4 power supply units 9/3 GD4 power supply units 9/4 Basic Units, Accessories 9/5 Technical data 9/6 Dimensions 9/12 9/2 Description
More informationPhase-sequence Phase-loss Relay
Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationPHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series
Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 350 900 ma Max. output power 35 W Nominal life-time up to 100,000 h For luminaires of protection
More informationPHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series
EL Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 30 900 ma Max. output power 20 W Nominal life-time up to 100,000 h For luminaires of protection
More informationMETRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14
3-349-813-3 1/9.14 Insulation measurement per EN 61557-2/VDE 413, part 2 Test voltages: 5 V, 1 V, 25 V, 5 V and 1 V Analog display of measured values and limit values Intelligent filter precise and measurement-dependent
More informationModular equipment. Presentation, standards. Standard contactors TeSys GC
Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationPHASED OUT. LED Driver Linear / area fixed output. Driver LCI 20W 150mA 400mA TOP lp TOP series. Product description
Product description EL Fixed output built-in LED Driver Constant current LED Driver Output current settable 150 400 ma Max. output power 20 W Nominal life-time up to 100,000 h For luminaires of protection
More informationPHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description
Product description EL Fixed output built-in LED Driver Constant current LED Driver Output current settable 15 4 ma Max. output power W Nominal life-time up to, h For luminaires of protection class I and
More informationDIGITAL PANEL METER N24 AND N25 METER SERIES
DIGITAL PANEL METER N24 AND N25 METER SERIES USER S MANUAL Contents 1. APPLICATION...5 2. METER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1 Fixing Way...7 4.2 External Connection Diagrams...8
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationControls Contactors and Contactor Assemblies Special Applications
Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for
More informationType: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description
Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals
More informationZelio Control Measurement Relays
Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and
More informationâ Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)
Technical information itemp TC TMT128 DIN rail mounted Temperature Transmitter for Thermocouples (TC) Application Temperature transmitter with fixed measuring ranges for converting TC input signals into
More informationProximity Sensor Terminology
The following descriptions refer to the European standard EN 60947-5-2. of 2007. The specifications given here are intended to be minimum performance values described by the standard. Alignment must not
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationSIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions
Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101
More informationPHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series
EL Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 35 9 ma Max. output power W Nominal life-time up to, h For luminaires of protection class I and
More information