Martin Carlen, Global Product Manager Dry Transformers, Transformers Days Compact Efficient Safe
|
|
- Austin Watts
- 5 years ago
- Views:
Transcription
1 Martin Carlen, Global Product Manager Dry Transformers, Transformers Days TriDry transformers TriDry transformers Compact Efficient Safe
2 TriDry Transformer An advanced d design with advanced d technology ABB s new TriDry transformer concept revolutionizes new thinking in the field of dry-type transformers A special core construction leads to significant product features TriDry completes ABB s dry-type yp transformer portfolio Premium features in a compact design! July, Slide
3 TriDry Transformer: compact I Triangular configuration gives excellence Magnetization of TriDry core A symmetrical, three-phase magnetic circuit => the symmetry of a -phase systems is preserved Wound core technology, continuously wound, without air-gaps, reducing the magnetic reluctance (resistance) of the core Optimized utilization of the core material in terms of magnetic flux distribution Almost round leg shape with 96% fillfactor of the core leg circle Results in a compact transformer July, Slide
4 TriDry Transformer: compact II Smaller footprint t enables broader varities of installation ti 5 kva transformer footprint TriDry Traditional e-core Characteristics: Smaller footprint (approx. 5 % less square footage) Length reduced Square footprint t form factor allows large variety of bus coordination options D views of TriDry model July, Slide
5 TriDry Transformer: compact III Reduced d weight for transport, t handling and installation ti Easier handling More efficient transport Simplified installation Matching characteristics: TriDry transformers are % lighter! July, Slide 5
6 TriDry Transformer: efficient I Reduced d no-load losses provide a competitive solution The core material is used in a highly efficient manner and saves on natural resources C B Y-axis: Annual costs (EUR) X-axsis: Transformer power rating (kva) *Base: 876 h operation per year Costs of no-load loss per year* (.5 EUR/kWh) 5 5 Characteristics: Reduced no-load losses TriDry transformers meet the more stringent no-load losses of the B loss class* almost naturally Transformers are often run at low load, therefore no-load losses play an important role in energy efficiency and operation costs A premium feature for a standard transformer without the premium cost 6 8. *according to EN55- July, Slide 6
7 TriDry Transformer: efficient II Savings due to reduced d operational costs No-load loss (NLL) A -5% A B C B k EcoDry Basic Standard Load loss (LL) A k TriDry A k % EcoDry Ultra EcoDry 99Plus Higher efficiency levels of TriDry compared to standard transformers More efficient units reduce operational costs during the transformer s life cycle A competitive, environment-friendly solution Transformer efficiency according to Class B B k! July, Slide 7
8 TriDry Transformer: premium features I Ti Triangular core leads to notable advantages Reduced harmonics Measurements of the harmonic content in the excitation current of TriDry transformers indicate strongly reduced harmonics in comparison to standard stacked core transformers even in the absence of a delta winding Measured harmonics in secondary current (% excitation, Dy-connection) % 5% % 5% % TriDry Stacked Core Y-axis: Harmonic content t X-axsis: Number of harmonics Reduced inrush current ABB tested for inrush current with positive and negative remaining magnetization (remanence). Tests on similar units indicate a strongly reduced inrush current for the TriDry transformer Inrush comparison Negative negative Bias Positive positive Bias TriDry Stacked Core Y-axis: Multiple of primary current X-axsis: Initial current direction July, Slide 8
9 TriDry Transformer: premium features II Ti Triangular core leads to notable advantages Reduced sound level The unique features of the core result in noise level improvements of 5- db compared to standard-grade steel. Improved EMC The compact and symmetrical coil arrangement results in a greatly reduced electromagnetic stray field around the transformer. July, Slide 9
10 TriDry Transformer: premium features III Comparison magnetic fields TriDry vs. standard d transformer kva, kv - - TriDry Brms / T > e-5 e-5 - e-5 e-6 - e-5 e-6 - e-6 r St tandard tran nsforme July, Slide
11 TriDry Transformer Product s special characteristics ti TriDry: Front view Standards: IEC676-: Product Scope: Ratings: kva up to 5 kva Voltage levels: kv up to kv TriDry: Bird s eye view Ambient: Indoor, 5 C up to + C Insulation Class: F July, Slide
12 TriDry Transformer: the premium without the premium Fast delivery times due to standardized di d ratings Four ratings, 6, 8 and kva for kv and kv will be available in stock Delivery within two weeks Delivery times and voltage levels for other ratings upon request Premium transformers without t a premium price, plus short delivery times! July, Slide
13 TriDry Transformer Customers benefits Compact: different and more compact footprint, less weight and length Efficient: % lower no-load loss at same material usage or up to % lighter for certain efficiencies Safe: all the advantages of dry-type insulation in a robust, symmetrical package Short delivery times: thanks to standardization; di ti most of the common ratings in stock July, Slide
14 July, Slide
ABB September Slide 1
Magdalena Puskarczyk, Radoslaw Jez, ABB Corporate Research Center, Krakow, Poland The Design of a Multilayer Planar Transformer for a DC/DC Converter with a Resonant Inverter Slide 1 The Design of a Multilayer
More informationHIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24
LECTURER-24 GENERATION OF HIGH ALTERNATING VOLTAGES When test voltage requirements are less than about 300kV, a single transformer can be used for test purposes. The impedance of the transformer should
More informationPicture perfect. Electromagnetic simulations of transformers
38 ABB review 3 13 Picture perfect Electromagnetic simulations of transformers Daniel Szary, Janusz Duc, Bertrand Poulin, Dietrich Bonmann, Göran Eriksson, Thorsten Steinmetz, Abdolhamid Shoory Power transformers
More informationBridgeport Magnetics Design Guide
Bridgeport Magnetics Design Guide Our design guide takes you step by step through the process of designing a toroidal transformer. No engineering design charges for all standard designs. State of the art
More informationSpring 2000 EE361: MIDTERM EXAM 1
NAME: STUDENT NUMBER: Spring 2000 EE361: MIDTERM EXAM 1 This exam is open book and closed notes. Assume f=60 hz and use the constant µ o =4π 10-7 wherever necessary. Be sure to show all work clearly. 1.
More informationK Factor Power Transformers
Ashley-Edison AsiaElectricTransformers (UK) K Factor Power Transformers DTKF series Low Voltage Dry Type K Factor Power Transformers AET-DTKF-2004-01: Page 1 Asia Electric Transformers, Entrepreneur Business
More informationArild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems
Arild Furnes,ATPA OGP/Petrobras workshop, 22.09.09 Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems September 24, 2009 Slide 1 Transformers for Ships and Offshore -
More informationAPPLICATION NOTES TRANSFORMERS
USER S MANUAL V - Rev. 0/00 APPLICATION NOTES TRANSFORMERS CD Automation S.r.l. Via F.lli Cervi, 4/44 000 Cantalupo di Cerro Maggiore (MI) - Italy Tel +39 033 5335 Fax +39 033 53356 e-mail: info@cdautomation.com
More informationGE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class
GE Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial
More informationRarely used, problems with unbalanced loads.
THREE-PHASE TRANSFORMERS Transformers used in three-phase systems may consist of a bank of three single-phase transformers or a single three-phase transformer which is wound on a common magnetic core.
More informationBasics of electrical transformer
Visit: https://engineeringbasic.com Complete basics and theory of Electrical Transformer Electrical Transformer is the most used electrical machine in power system. Both in the power transmission and distribution
More informationISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer
ISSN: 2454-132X Impact factor: 4.295 (Volume 3, Issue 6) Available online at www.ijariit.com Modeling and Analysis of Transformer Divyapradeepa.T Department of Electrical and Electronics, Rajalakshmi Engineering
More informationThe power transformer
ELEC0014 - Introduction to power and energy systems The power transformer Thierry Van Cutsem t.vancutsem@ulg.ac.be www.montefiore.ulg.ac.be/~vct November 2017 1 / 35 Power transformers are used: to transmit
More information3-Phase Transformers. Author: Sergey Dubatov. belfuse.com/signal
3-Phase Transformers Author: Sergey Dubatov 2 A transformer is an electrical device which, by electromagnetic induction, transforms power between circuits at the same frequency, usually changing the values
More informationUnderstanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies
Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies 1 Definitions EMI = Electro Magnetic Interference EMC = Electro Magnetic Compatibility (No EMI) Three Components
More informationAmveco Toroidal Solutions. Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications.
Amveco Toroidal Solutions Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications. AMVECO TOROIDAL SOLUTIONS Acme Electric s Amveco brand specializes
More informationLiquid-Filled Transformers
Liquid-Filled Transformers Custom Transformers at Standard Prices NIAGARA TRANSFORMER CORP. Induction Furnace Transformer Cycloconverter Rectifier Duty Transformer Arc Furnace Transformer Full Range of
More informationContents. About the Authors. Abbreviations and Symbols
About the Authors Preface Abbreviations and Symbols xi xiii xv 1 Principal Laws and Methods in Electrical Machine Design 1 1.1 Electromagnetic Principles 1 1.2 Numerical Solution 9 1.3 The Most Common
More informationStatic Frequency Converter TMP-TS250. Series
Static Frequency Converter TMP-TS250 Series Preface SFC is a load commutated inverter LCI, which drives a gas turbine generator like a synchronous motor, and accelerates up to the gas turbine s self-sustaining
More informationBrown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS
SECTION 16461C - DRY TYPE TRANSFORMERS PART 1 - GENERAL 1.1 This section includes design and performance requirements for dry-type transformers rated for use on secondary distribution systems rated 600
More informationMGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide
MGM Transformer Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide MGM Transformer Company 5701 Smithway Street Commerce, CA 90040 www.mgmtransformer.com Phone: 323.726.0888
More informationTEST VOLTAGES INFLUENCE ON TURN RATIO TESTING ndb Technologies model ART-3D
TEST VOLTAGES INFLUENCE ON TURN RATIO TESTING model ART-3D Application has been working with several transformer maintenance crews manufacturers over the years. One of the prevalent challenges was obtaining
More informationStatic Frequency Converter TMP-TS370. Series
Static Frequency Converter TMP-TS370 Series Preface SFC is a load commutated inverter (LCI), which drives a gas turbine generator like a synchronous motor, and accelerates up to the gas turbine s self-sustaining
More informationand cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.
-156 Purpose & Industrial Control Purpose (1000 kva and Below) mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. shall be manufactured
More informationMEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly
MEDIUM VOLTAGE PRODUCT PARAMETERS GUIDE How to specify the indoor instrument transformers correctly The range of electric values in the power supply systems is very extensive. This is why it is necessary
More informationWalchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer
Walchand Institute of Technology Basic Electrical and Electronics Engineering Transformer 1. What is transformer? explain working principle of transformer. Electrical power transformer is a static device
More informationDry Type Transformers Full Line Catalog. jeffersonelectric.com
Dry Type Transformers Full Line Catalog jeffersonelectric.com The Transformer Authority PIONEER TRANSFORMERS: Why us? Scale We produce over 100,000 transformers every year. With this high level of production
More information1/23/2003. Sensor presentation
1/23/2003 Sensor presentation Product Scope A Sensor is a device intended to transmit a signal corresponding to the primary current or voltage to the secondary equipment. Power IT Sensors are typically
More information(2) New Standard IEEE P (3) Core : (4) Windings :
(d) Electrical characteristics (such as short-circuit withstand, commutating reactance, more number of windings, etc); (e) Longer life expectancy; (f) Energy efficiency; (g) more demanding environment.
More informationVIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs
VIRGINIA TRANSFORMER CORP Individual solutions from a global perspective Drive & Rectifier Transformersrs Oil Drilling Paper Mill Virginia Transformer Commitment to our Customers Industry s Shortest Production
More informationLecture 16 Transformer Design
Design and Simulation of DC-DC converters using open source tools Prof. L. Umanand Department of Electronics System Engineering Indian Institute of Science, Bangalore Lecture 16 Transformer Design In this
More informationABB CUSTOMER WORLD, MARCH 13-16, 2017 Sensors in Critical Applications Ron Pate, Product Manager, Instrument Transformers and Sensors
ABB CUSTOMER WORLD, MARCH 13-16, 2017 Sensors in Critical Applications 050511 Ron Pate, Product Manager, Instrument Transformers and Sensors Sensors in Critical Applications Presentation code 050511 Speakers
More informationSHUNT REACTOR CORES Up to 765 kv MVAR
SHUNT REACTOR CORES Up to 765 kv - 300 MVAR CORPORATE PROFILE Plant-Slovakia Kullar Plant-Turkey Vadodara Plant-India ENPAY: A GLOBAL BRAND, A ROOTED COMPANY Established in 1978, ENPAY is a world-known
More informationTransformer Factory Testing
Transformer Factory Testing John J. Foschia Test Engineer John.Foschia@spx.com September 2018 Reasons for Testing Compliance with user specifications Assessment of quality and reliability Verification
More informationLine Frequency Transformer
Line Frequency Transformer For frequencies of 50/60 Hz, specify a Frequency Transformer. Line Line Frequency Transformers are customized to meet customer requirements, and are available in various ratings.
More informationDescription & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...
SECTION BUCK-BOOST TRANSFORMERS A simple and economical way to correct offstandard voltages... from 95 to 500 volts; single and three phase, in sizes up to 60 kva. Simplified buck-boost rating charts make
More informationPANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer
PANELMDP Main Distribution Panel Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Product Type PANELMDP Eaton Corp 1.0 (lbs/each) Three Phase Energy Efficient
More informationXu Xiao Ming, AP Services, March 2010 Machine services Life expectance analysis program (LEAP)
Xu Xiao Ming, AP Services, March 2010 Machine services Life expectance analysis program (LEAP) April 12, 2010 Slide 1 Content MV Machine Winding Insulation Stress LEAP Methodology LEAP Standard LEAP from
More informationOutcomes from this session
Outcomes from this session At the end of this session you should be able to Understand what is meant by the term losses. Iron Losses There are three types of iron losses Eddy current losses Hysteresis
More informationYour Presenters. > Thomas Patzner Product Manager, Low Voltage Transformers. > Marquette University Electrical Engineering. > Apprentice Electrician
Your Presenters > Thomas Patzner Product Manager, Low Voltage Transformers > Marquette University Electrical Engineering > Apprentice Electrician > Low Voltage Transformers - Co-op (Square D Company) (lab
More informationWelcome to Wurth Electronics product presentation. This module overviews the available magnetics solutions for various LED lighting applications,
Welcome to Wurth Electronics product presentation. This module overviews the available magnetics solutions for various LED lighting applications, their key features, and their various applications. 1 Before
More informationsave energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers
save energy, it is precious Mfg. of all types of Distribution / Power & Furnace Transformers SYNERGY transformers SAFETY AND EFFICIENCY, COMBINED WITH LONG-TERM RELIABILITY, ARE THE HALLMARKS OF WORLD-RENOWNED
More informationPhase Shifter Application Workshop. Siemens Energy, Inc.
Phase Shifter Application Workshop Siemens Energy, Inc. PJM Power Pool, March, 2015 siemens.com/energy Phase Shifter Application Workshop Phase Shifting Transformers Principles, Design Aspects and Operation
More informationSensor Technology. Applications for medium voltage
Sensor Technology Applications for medium voltage Contents Introduction to sensor technology... 3 Sensors versus instrument transformers... 6 Advantages for builders and users of switchgear... 7 The impact
More informationTRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER
TRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER PRODUCT RANGE POWER INDUCTORS Toroidal technology, driven by 20 years of R&D. POWER TRANSFORMERS
More informationSPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)
SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) 0.415/33kV DESIGN AND CONSTRUCTION General 1. The transformer shall be three phase, oil immersed type, air cooled, core type, outdoor
More informationComparison of Leakage Impedances of Two Single-phase Transformers
Aim Comparison of Leakage Impedances of Two Single-phase Transformers To understand the effect of core construction on leakage impedance in a single-phase transformers To understand factors affecting leakage
More informationProducts for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers
Products for High Voltage Application AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers Technical parameters Value Highest voltage for equipment 1.2 kv Power frequency voltage,
More informationCURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS
CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS VACUUMSCHMELZE GmbH & Co. KG (VAC) is one of the worldwide
More informationTRANSFORMER THEORY. Mutual Induction
Transformers Transformers are used extensively for AC power transmissions and for various control and indication circuits. Knowledge of the basic theory of how these components operate is necessary to
More informationSTRAY FLUX AND ITS INFLUENCE ON PROTECTION RELAYS
1 STRAY FLUX AND ITS INFLUENCE ON PROTECTION RELAYS Z. GAJIĆ S. HOLST D. BONMANN D. BAARS ABB AB, SA Products ABB AB, SA Products ABB AG, Transformers ELEQ bv Sweden Sweden Germany Netherlands zoran.gajic@se.abb.com
More informationFERRORESONANT PROGRAM MANUAL V12.0
FERRO OPTIMIZED PROGRAM SERVICE, LLC Electro-Magnetic Design Using Advanced Computer Techniques FERRORESONANT PROGRAM MANUAL V12.0 www.opsprograms.com opseast@opsprograms.com FERRO PROGRAM DESCRIPTION
More informationPARTNER ALTERNATORS LSA 40-4 Pole
23 kva - 50 Hz 12,5 28 kva - 60 Hz 4250 en - 2011.03 / c PARTNER ALTERNATORS LSA 40-4 Pole Electrical and mechanical data SPECIALLY ADAPTED TO APPLICATIONS The LSA 40 alternator is designed to be suitable
More informationDemagnetization of Power Transformers Following a DC Resistance Testing
Demagnetization of Power Transformers Following a DC Resistance Testing Dr.ing. Raka Levi DV Power, Sweden Abstract This paper discusses several methods for removal of remanent magnetism from power transformers.
More informationTransformers. Objectives
Transformers Objectives Explain mutual inductance Describe how a transformer is constructed and how it works Explain how a step-up transformer works Explain how a step-down transformer works Discuss the
More informationIsolation Transformer Series
Isolation Transformer Series Unit Shown With Options ITS Series - Isolation Transformer Series The La Marche Isolation Transformer Series (ITS) is designed for installation in industrial and harsh environment
More informationRitz Instrument Transformers GmbH. Welcome
Ritz Instrument Transformers GmbH Welcome About Ritz together with over 200 years of experience in instrument transformer production since 1945 since 1945 since 1945 since 1904 RITZ Group - Organization
More informationImprovements of LLC Resonant Converter
Chapter 5 Improvements of LLC Resonant Converter From previous chapter, the characteristic and design of LLC resonant converter were discussed. In this chapter, two improvements for LLC resonant converter
More informationFGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI
FGJTFWP"KPUKWG"QH"GEJPQNQI[" FGRTOGP"QH"GNGETKEN"GPIKPGGTKPI" GG"46"JKIJ"XQNIG"GPIKPGGTKPI Resonant Transformers: The fig. (b) shows the equivalent circuit of a high voltage testing transformer (shown
More informationTHE UNDER HUNG VOICE COIL MOTOR ASSEMBLY REVISITED IN THE LARGE SIGNAL DOMAIN BY STEVE MOWRY
THE UNDER HUNG VOICE COIL MOTOR ASSEMBLY REVISITED IN THE LARGE SIGNAL DOMAIN BY STEVE MOWRY The under hung voice coil can be defined as a voice coil being shorter in wind height than the magnetic gap
More informationHPS Universal BUCK-BOOST TRANSFORMERS
BUCK-BOOST TRANSFORMERS Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More information500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor
500 kva Dry-type Isolation Transformer - 13200V-Delta to 208Y/120V 3PH - NEMA 1/Indoor Part #: MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Page: 1 The MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Dry-type Isolation
More informationbasicdim Wireless basicdim Wireless LED Drivers
LED Drivers Driver LC 35W 24V bdw SC PRE2 premium series constant voltage Product description Dimmable 24 V constant voltage LED Driver for flexible constant voltage strips enables different dimming options
More information1 K Hinds 2012 TRANSFORMERS
1 K Hinds 2012 TRANSFORMERS A transformer changes electrical energy of a given voltage into electrical energy at a different voltage level. It consists of two coils which are not electrically connected,
More informationPremium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated
Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated Catalog 7400CT1001 2010 Class 7400 CONTENTS Description.............................................
More information3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)
DHANALAKSHMI COLLEGE OF ENGINEERING, CHENNAI DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE 6401 ELECTRICAL MACHINES I UNIT I : MAGNETIC CIRCUITS AND MAGNETIC MATERIALS Part A (2 Marks) 1. List
More informationBALANCED DRIVE. Line of speaker units designed with optimized motor symmetry. The Wavecor Balanced Drive Technology
BALANCED DRIVE Line of speaker units designed with optimized motor symmetry. The Introduction The Balanced Drive line of loudspeaker transducers is yet another example of Wavecor paying attention to every
More informationINTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers
INTERNATIONAL TRANSFORMERS Acme Electric s broad selection of CSA energy efficient transformers International Transformers What is CSA C802.2 Compliant? On January 1, 2005, the Canadian Energy Efficiency
More informationSHARDA Make Harmonics Filter
SHARDA Make Harmonics Filter SHARDA offers perfect solution to minimize Harmonics level of industries where non-linear load like, VFD, Electronics load, Convertors, Voltage booster equipment s are present.
More informationCurrent / residual current and voltage transformers. Current / residual current and voltage transformers
Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...
More informationOne transformer inrush current calculation method based on field-circuit-network coupled co-simulation
4th National Conference on Electrical, Electronics and Computer Engineering (NCEECE 2015) One transformer inrush current calculation method based on field-circuit-network coupled co-simulation Xiaobin
More informationThree Winding Transformer.
Three Winding Transformer. By G. K. KAISER (Transformer Engineer, Mitsubishi Denki-Kabushikikaisha.) Abstract. Three winding transformers afford many advantages on large power systems and their use has
More informationInfluence of the Manufacturing Process on the Magnetic Properties of Electrical Steel in E-Cores
Influence of the Manufacturing Process on the Magnetic Properties of Electrical Steel in E-Cores W. Deprez 1, J. Schneider 2, T. Kochmann 2, F. Henrotte 1 and K. Hameyer 1 1 K.U.Leuven ESAT / ELECTA, Kasteelpark
More informationAPPENDIX 4 TYPICAL LAYOUT, VALUES AND CONSTANTS
109 APPENDIX 4 TYPICAL LAYOUT, VALUES AND CONSTANTS TYPICAL LAYOUT The purpose of a transformer is to transfer energy from the input to the output through the magnetic field. The layout of a partial typical
More informationTap Changer Analyzer & Winding Ohmmeter RMO25TD
Tap Changer Analyzer & Winding Ohmmeter RMO25TD Test current 5 ma 25 A DC Rapid automatic demagnetization AC Current monitoring channel Lightweight 9,5 kg Measuring range 0,1-2 k Two voltage sense channels
More informationGENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS
GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS Acme offers a large selection of Dry-Type Distribution Transformers. Ranging from 600 Volt and below, in both Single and Three Phase, you re sure to find
More informationTransformer differential protection
Transformer differential protection Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970883) Features Three phase differential protection with two, three, five or
More informationLecture 4 Power System Instrumentation. Course map
Lecture 4 Power System Instrumentation 1 Course map 2 1 Outline of the Lecture Instrument Transformers Voltage Transformer Current Transformers Measurement Setups Instrumentation 3 The Current Transformer
More informationLow Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned
Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design
More informationSAMSUNG ELECTRO-MECHANICS CO., LTD
Model Name : Features : ㅡ Suitable for LED lighting application ㅡ UL8750, UL1310 Class 2 ㅡ For use in Dry and Damp Location ㅡ Full-protection provided: OCP/OVP/OTP/SCP ㅡ 0-10V Dimming Control ㅡ IP67 ㅡ
More informationLED Driver Constant voltage
Driver LCU 35W 12/24V IP20 EXC EXCITE indoor IP20 series Product description LED Driver Universal input voltage range Constant output voltage Push terminals for simple wiring Nominal life-time up to 50,000
More informationA Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.
A Comparison Between MIL-STD and Commercial EMC Requirements Part 2 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC immunity
More informationActive. Advanced Materials The Key to Progress
Active Current SEnsors FOR PCB MOUNTING Advanced Materials The Key to Progress The Company VACUUMSCHMELZE VACUUMSCHMELZE GmbH & Co. KG (VAC) is one of the world s leading producers of special metallic
More informationDiscipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1
Post: Last Amended on - Page 1 of 6 LOCATION 1 I. TRANSFORMERS AND REACTORS 1. 500 MVA, 765 kv 500 MVA, 400 kv Ratio & Polarity Check Magnetic Balance & Magnetizing Current Measurement at Low Voltage Vector
More informationMEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance
MEDIUM VOLTAGE PRODUCT KOKM Cable current instrument transformers Instruction for Installation, use and maintenance 2 KOKM CABLE CURRENT INSTRUMENT TRANSFORMERS INSTRUCTION FOR INSTALLATION, USE AND MAINTENANCE
More informationSGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:
SGMF(T) series Onsite Mobile AC High Voltage Test System On-site AC high voltage test systems are used for voltage withstanding test, partial discharge measurement, tan delta measurement on those instrument
More informationOnsite Mobile AC High Voltage Test System
TSGMF(T) series Onsite Mobile AC High Voltage Test System Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument
More informationTitle Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)
Discipline Engineering Standard NSW Category Electrical Title Substation Auxiliary Transformer from Rectifier Transformer Secondary Reference Number PDS 01 (RIC Standard: EP 05 00 00 01 SP) Document Control
More informationLED Driver Constant voltage. Driver LC 100W 24V SC SNC ESSENCE series
Driver LC 100W 24V SC SNC ESSENCE series Product description LED Driver Output voltage 24 V Max. output power 100 W Dimmable via PWM LED dimmers Nominal life-time up to 50,000 h 5-year guarantee Typical
More informationBasic Principles and Operation of Transformer
Basic Principles and Operation of Transformer CONSTRUCTIONAL ASPECTS Cores In order to enhance core s magnetic properties, it is constructed from an iron and silicon mixture (alloy). The magnetic core
More informationMETRAClip85 and 86 Clamp Multimeters
3-349-794-03 1/8.14 Current and frequency measurement via clamp meter: 600 A AC TRMS and 900 A DC (automatic or manual switching) Multimeter functions via connector sockets: V (AC TRMS and DC) up to 1000
More informationTechnical Datasheet. Delta Power 1000A / 400A AC-DC
Delta 1000A / 400A AC-DC Technical Datasheet Delta 1000A/ 400A AC-DC is specially designed for Measurement of AC-DC POWER and quality parameters. Up to 49th Individual Harmonics Non contact voltage detection.
More informationCode No: R Set No. 1
Code No: R05310204 Set No. 1 III B.Tech I Semester Regular Examinations, November 2007 ELECTRICAL MACHINES-III (Electrical & Electronic Engineering) Time: 3 hours Max Marks: 80 Answer any FIVE Questions
More informationEmbedded inductor design and electromagnetic compatibility issues
Embedded inductor design and electromagnetic compatibility issues J. Kundrata, D.Bandic and A. Baric University of Zagreb IMOLA Final Workshop Slide 1/22 Outline Design challenges Planar inductor designs
More informationMETRAClip87 and 88 Clamp Multimeters
3-349-795-03 1/7.14 Current and frequency measurement via clamp meter: METRAClip87: 1500 A AC TRMS and 1500 A DC METRAClip88: 2000 A AC TRMS and 3000 A DC Multimeter functions via connector sockets: V
More informationNO-LOAD OPERATION OF SINGLE-PHASE TRANSFORMER AT LOW FREQUENCIES
017 INTERNATIONAL SCIENTIFIC CONFERENCE 17-18 November 017, GABROVO NO-LOAD OPERATION OF SINGLE-PHASE TRANSFORMER AT LOW FREQUENCIES Branko Koprivica 1, Sandra Milunovic Koprivica University of Kragujevac,
More informationMica Element Support High Current Interruption Element. Welded Element Joints
Construction A 3/8-16 UNC 2B Thd..75 Deep 1.00 (25.4) Brass Caps Low Current Interruption Element (Includes Patented Damage Sensor Resin-Rich Filament Wound Glass/Epoxy Body Length B C Compacted Quartz
More informationKEVCY 24 RE1; KEVCY 24 RF1 Indoor combined sensor; Indoor voltage sensor
Medium Voltage Product KEVCY 24 RE1; KEVCY 24 RF1 Indoor combined sensor; Indoor voltage sensor Parameters for Application Unit Value Rated primary current of application A up to 630 Rated primary voltage
More informationPARTNER ALTERNATORS LSA Pole
90 16 kva - 0 Hz 1 6 kva - 60 Hz 38 en - 11.04 / g PARTNER ALTERNATORS LSA 44.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 44.2 alternator is designed to be suitable
More information