Ritz Instrument Transformers GmbH. Welcome
|
|
- Clare Hoover
- 5 years ago
- Views:
Transcription
1 Ritz Instrument Transformers GmbH Welcome
2 About Ritz together with over 200 years of experience in instrument transformer production since 1945 since 1945 since 1945 since 1904
3 RITZ Group - Organization RITZ Foundation Headquarters KG Ritz Messwandler GmbH & Co. Hamburg RITZ Marchtrenk Low and medium voltage RITZ Instrument Transformers GmbH Ritz Wirges Ritz Kirchaich RITZ Dresden RITZ Shanghai Medium voltage RITZ Hartwell Low voltage Medium voltage Medium voltage Medium voltage RITZ Kecskemet Components Duromer Dresden Resin and Cast resin products
4 Ritz & It s Subsidiaries Incorporated in 1945, Ritz is one of the leaders in the field of Instrument transformers and solid insulated bus bars for the transmission of high current. Ritz production and sales offices are located across the world RITZ Hamburg Headquarters Management / Administration / Finance / Controlling / Human Resources / R&D RITZ Wirges Medium voltage indoor and outdoor current and voltage transformers up to 72,5kV Cast resin insulated distribution transformers up to 20 MVA RITZ Kirchaich Medium voltage indoor current transformer Fully insulated busbar systems RITZ Dresden Duromer Medium voltage indoor current and voltage transformers up to 36kV Ring core current transformers Customized cast resin products
5 Ritz & It s Subsidiaries (Cont ) RITZ Marchtrenk (Austria) RITZ Kecskemét (Hungary) RITZ Shanghai (China) Medium voltage indoor and outdoor current and voltage transformers up to 72,5 kv Complete range of low voltage current and voltage transformers Transformers for rail vehicels Iron Cores and components for CT s Sub-supplier for the RITZ group Sales office Medium voltage current and voltage transformers Ring core current transformers RITZ Hartwell (USA) Low voltage current and voltage transformers
6 Low Voltage Transformers
7 Medium Voltage Instr. Transf. - Indoor - Epoxy resin current and voltage transformers - Current and voltage sensors, epoxy resin insulated - Combined current / voltage sensors
8 Medium Voltage Instr. Transf. - Outdoor - Epoxy resin current and voltage transformers - Designs up to 72,5 kv
9 Metal-enclosed enclosed Instrument Transformers
10 Generator Current Transformers
11 Special Transformers for Trains
12 Production & Test Equipment Production Equipment - Primary Winding Machines - Secondary Winding Machines - Kiln for heating up process of the active part - Casting Machine with 18 clamping machines - Kiln for cooling down process of the product after molding process Test Equipment - Insulation Test 5 kv voltage tester - Partial Discharge test Test transformer for 150 KVA AC/1A Measuring condenser Partial Discharge Measurement Equipment - Accuracy High Current Standard Transformer for 5000 A Burden according to IEC & IEEE standard
13 Power Transformers Glass-fibre-vacuum technology up to 36kV & 20MVA
14 Epoxy Cast Resin Power Transformers 50 kva bis 20 MVA RITZ manufacture dry type transformers for ratings up to 20 MVA and 36 kv Application range Power Transformers (Cont ) Power Distribution Rectifier Drives Generator Excitation Transmitter Systems Earthing Systems Traction Supply systems Oil Platforms / Vessels Laboratory systems Customized service Transformer Installation Disposal of existing oil and PCB Transformers Start-up 30 kv; 20MVA rated power; total weight 38 t 3 phase transformer bank Power: 8055 KVA Width: 1,80m Height: 3,00m Length: 6,90m Gewicht: 18.3 t
15 Power Transformers (Cont ) Construction design by application of the latest design systems in 2D & 3D Winding of a transfomer cast coil for HV side max. diameter 1,3m Test facility Thermo scan of a 5MVA power transformer during heat run test
16 Fully Insulated Bus Bar System - SIS SIS - Solid Insulation System Electrical Rating Parameters: System voltage up to 52 kv. Rated current up to A single system. Double system up to A. Partial discharge free up to 1,5x phase to ground voltage System Specific Benefits Compact design Low space requirement Small bending radii 3-dimensional geometric shape No maintenance Production Length 13 m x 3 m x 3 m
17 SIS - Company History-MWB Established 1946 by Dr. Ing. Friedrich Raupach 1956 first fully resin insulated instrument transformer 1965 first resin insulated outdoor instrument transformer - In 1984, Ritz produced first installation of SIS bus bars 1989 MWB is split into three different companies - Establishment of MWB Mittelspannung GmbH 1992 sale of MWB Mittelspannung to Sadtem 1999 establishment of MWB Messwandler GmbH as 100% daughter of WTW Wirges GmbH 2007 merger of the companies WTW, MWB and Ritz to RITZ Instrument Transformers GmbH
18 SIS Bus Bar Design Principle 1 Aluminum or copper conductor. 2 The main insulation consists of epoxy resin impregnated crepe paper. The impregnation process is performed under vacuum. 3 Capacitive graded area implementing of capacitive layers by using semi-conductive crepe paper. 4 The last layer is grounded and ensure touch-safe bus bar
19 SIS Production Process Indoor Bus Bar Paper insulated conductor, vacuum sealed by using a shrinking sleeve. Drying process under vacuum. Impregnation process conducted under vacuum. Total process under temperature control. Outdoor Bus Bar Additional Steps Indoor Bus bar covered by stainless steel tube. Adding of outdoor material.
20 SIS Multiple Bus Bar Connection Performed with flexible connectors Allows thermal compensation. Compensating of installation tolerances Connecting Sleeve Insulated Bus Bar Expansion Joint Insulated Connecting Sleeve Contact Spring Fully insulated Contact Tube Touch safe Capacitive graded Protection class IP45, higher classes on request Grounding Screw
21 SIS End Bus Bar Connection Conductor end with flat terminal according DIN Conductor end with round bolt According to customer s specification Gas-tight connection to GIS switchgear - Metal flange fixed on the beginning of the grounded part of the bus bar - Connection by using contact bolts standard - Customized design Resin cone 1. Contact bolt 2. Conductor 3. Insulation 4. Metal flange Flange Earthing screw Contact bolt Spring Conductor Paper resin
22 SIS Fixation Flexible mounting system Ritz design Aluminum C-profiles Standard angles Hammer head screw (T-screw) Fixing clamps - Fixed bearing - Slide bearing to allow axial move to allow movement caused by thermal expansions. Calculation Criteria Short circuit forces Natural system frequency & its harmonics to avoid resonances Bus bar diameter Phase distance Mass of bus bar Bending strength
23 Sample of a drawing sheet SIS Application
24 SIS Application (Cont ) Bus Bar Installation Example Taking care of intersection of other metal constructions minimum distance 300 mm 24 kv 3150 A Horizontal connecting sleeve Vertical connecting sleeve
25 SIS Application (Cont ) Wall bushing entering a switchgear from underneath Connection sleeves vertical mounted
26 SIS Application (Cont ) Connection within a compartment of an air insulated switchgear Connection with sealing flanges
27 SIS Indoor Application Indoor Installation Limited space conditions Two Indoor Systems parallel Indoor Installation Bus Bar with Current Transformer Installation
28 SIS Outdoor Application Outdoor installation with roofing connection to transformer Capacitive grading of bus bar insulation covered by cast-on sheds to increase creepage distance
29 SIS Outdoor Application (Cont ) Outdoor Installation Connection of a Power Transformer with High Flexible Connectors Outdoor Installation Sealing of a connection point (transformer box) with rubber bellows (IP64)
30 SIS Outdoor Application (Cont ) Outdoor Installation Sealing of a connection sleeve (IP 64) Outdoor Installation Bus Bar routing
31 Ritz Instrument Transformers GmbH Thank You for Your Attention
Voltage Instrument Transformer Medium Voltage Block Type 7,2 kv - 24 kv
Voltage Instrument Transformer Medium Voltage Block Type 7,2 kv - 24 kv Standard RITZ Instrument Transformers GmbH Core competency Under the trading name RITZ Instrument Transformers GmbH RITZ has been
More informationOhmic Voltage Sensor GSER 16
Ohmic Voltage Sensor GSER 16 including Isolating Amplifier EGIW 804 AV Medium Voltage Applications Direct, Alternating and Mixed Voltages Wide Frequency Range Electrical Isolation Ohmic Voltage Sensor
More informationMetal Clad Instrument Transformers
Metal Clad Instrument Transformers Metal Clad Combi Instrument Transformer 12-36 kv (Current and Voltage Instrument Transformer) Technical data Type (Size) KGBEI 12 KGBEI 24 KGBEI 36 KGBEA 12 KGBEA 24
More informationArild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems
Arild Furnes,ATPA OGP/Petrobras workshop, 22.09.09 Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems September 24, 2009 Slide 1 Transformers for Ships and Offshore -
More informationCapacitive voltage transformers
Capacitive voltage transformers Outdoor operation Oil-paper insulated ECF (72 550) kv General description Capacitive voltage transformers of type ECF are used in high-voltage switchgears from 72 to 550
More informationInductive Voltage Transformers. Types VEOT and VEOS
Inductive Voltage Transformers Types VEOT and VEOS Inductive Voltage Transformers Introduction Trench is a recognized world leader in the design and manufacture of high voltage equipment for application
More informationCombined Instrument Transformers. Types IVOKT and TMC
Combined Instrument Transformers Types IVOKT and TMC Combined Instrument Transformers Introduction Trench is a recognized world leader in the design and manufacture of high voltage equipment for application
More information36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)
CEB STANDARD 022 : 1994 Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEYLON ELECTRICITY BOARD SRI LANKA Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEB Standard 022 : 1994
More information3. COMBINED TRANSFORMERS Oil-paper insulation
3. COMBINED TRANSFORMERS Oil-paper insulation 123 kv Combined transformers. 26 Instrument transformers High voltage INTRODUCTION Combined instrument transformers contain a current transformer and an inductive
More informationNeutral Earthing. For permanent or temporary neutral earthing in HV systems
Neutral Earthing Resistors RESISTORS For permanent or temporary neutral earthing in HV systems For continuous or temporary low-resistance neutral grounding in medium voltage systems Neutral point connection
More informationSGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:
SGMF(T) series Onsite Mobile AC High Voltage Test System On-site AC high voltage test systems are used for voltage withstanding test, partial discharge measurement, tan delta measurement on those instrument
More informationOnsite Mobile AC High Voltage Test System
TSGMF(T) series Onsite Mobile AC High Voltage Test System Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument
More informationUser s Manual For CT Model IMB
User s Manual For CT Model IMB 2 of (13) Contents: A. Introduction... 3 B. Steps on receipt and opening the cases... 3 C. Transportation and handling... 3 D. Unpacking the transformer... 4 E. Storage...
More informationGE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class
GE Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial
More informationand cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.
-156 Purpose & Industrial Control Purpose (1000 kva and Below) mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. shall be manufactured
More informationConvincing technology creates compact performance
siemens.com/energy Convincing technology creates compact performance The GEAFOL Basic: the optimum foundation for power distribution Answers for energy. Contents The GEAFOL Basic: A true GEAFOL and more
More informationPURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS
PURCHASE SPECIFICATIONS OF 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS SPECIFICATION NO. : OR12423 REVISION NO. : Rev 00 DATE : 01.03.2011 DISTRIBUTION : PI - 4 copies O/C - 1 copy PREPARED BY
More informationLiquid-Filled Transformers
Liquid-Filled Transformers Custom Transformers at Standard Prices NIAGARA TRANSFORMER CORP. Induction Furnace Transformer Cycloconverter Rectifier Duty Transformer Arc Furnace Transformer Full Range of
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK PO Box 25876 Safat 13119 Kuwait Contact: Mr Atul Madhukar Vaidya Tel: +965 1822600 Fax: +965 24761963 E-Mail: factory@ahleiasg.com Website:
More informationCOMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3
CONTENTS COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3 CONSTRUCTION... 4 ~ 5 A. CORE AND FRAME... 4 B. COIL... 5 C. TEMPERATURE INDICATOR... 5 CHARACTERISTICS... 6 MANUFACTURING FACILITIES...
More informationPower Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.
Power Voltage Transformers for Air Insulated Substations THE PROVEN POWER. Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the
More informationResistive capacitive voltage divider
Resistive capacitive voltage divider Outdoor operation Oil insulated ROF 72 550 kv General description Resistive capacitive voltage dividers type ROF (RC divider) are used in high voltage networks within
More informationOUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:
OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description: VTOP 2(1) X Dry Insulated voltage transformer (VT) There are two designs of this voltage transformers: - VTOP 1-X single phase, dry insulated
More informationDATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO
PART - A : SPECIFIC REQUIREMENTS THIS DATA SHEET IS APPLICABLE FOR IN BOILER A CLIMATIC CONDITIONS PACKAGE 1 DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.71 MTRS. 3 RELATIVE HUMIDITY 74 %
More informationMGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide
MGM Transformer Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide MGM Transformer Company 5701 Smithway Street Commerce, CA 90040 www.mgmtransformer.com Phone: 323.726.0888
More informationIntroducing 50Hz Solutions
! Introducing 50Hz Solutions supplies a range of quality high voltage equipment to customers around Australia and New Zealand. 50Hz Solutions commenced operations in 2010 as a subsidiary of Powereng Pty
More informationSHARDA Make Harmonics Filter
SHARDA Make Harmonics Filter SHARDA offers perfect solution to minimize Harmonics level of industries where non-linear load like, VFD, Electronics load, Convertors, Voltage booster equipment s are present.
More informationDMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)
DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- 0005/ DMRC-E-TR-TRANSF-05 SPECIFICATIONS FOR THREE PHASE 33 kv/415 V AUXILIARY Issued on: Date
More informationELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER
Approval Amendment Record Approval Date Version Description 03/05/2017 1 Initial issue PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 1 of 13 Table of Contents 1. Purpose...
More informationTMC Transformers TMC
TMC Product & Technology Presentation Cast Resin Transformer (CRT) History Cast resin transformers first appeared in Germany during the 1960s. This new style of dry type transformer was developed with
More informationResistive capacitive voltage divider
Resistive capacitive voltage divider Outdoor operation Oil-paper insulated ROF (72 550) kv General description Resistive capacitive voltage dividers type ROF ( RC divider ) are used in high voltage networks
More informationMEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017
MEDIUM VOLTAGE TERMINATIONS CATALOGUE 01 NEXANS NETWORK SOLUTIONS DIV. EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More informationa Nexans company Catalogue 2009
a Nexans company Catalogue 009 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage
More informationTECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES
INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION October 2014 TECHNICAL DESCRIPTION 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES I. SCOPE This
More informationGroup F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A
Group F : No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS Table : A No. Description 1. Make & Manufacturer 2. Place of Manufacturer 3. Voltage Ratio 4. Rating
More informationCoil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900
Coil Products Coil Products Customer partnership around the globe More than 250,000 coil products delivered to more than 170 countries. More than 60 years of operational experience. 35,000 in Europe 13,000
More informationNexans Network Solutions Div. Euromold
Catalogue 0 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for
More information(
(www.xatianhong.com) Introduction to XATH Xi'an Tianhong Electric Co., Ltd. (XATH) is a solely state-owned enterprise, set up by China Shipbuilding Industry Corporation (CSIC). It is one of the largest
More informationSwiss quality combined with global experience
Product Overview Swiss quality combined with global experience PFIFFNER is a values-driven Swiss company with: n over 85 years of experience and an enormous amount of know-how n long-lasting partnerships
More informationa Nexans company Catalogue 2012
a Nexans company Catalogue 0 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable
More information3-Phase Transformers. Author: Sergey Dubatov. belfuse.com/signal
3-Phase Transformers Author: Sergey Dubatov 2 A transformer is an electrical device which, by electromagnetic induction, transforms power between circuits at the same frequency, usually changing the values
More informationsiemens.com/transformers Convincing technology creates compact performance The GEAFOL Basic: the optimum foundation for power distribution
siemens.com/transformers Convincing technology creates compact performance The GEAFOL Basic: the optimum foundation for power distribution Contents The GEAFOL Basic: A true GEAFOL and more 3 Construction
More informationMESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER
Engineering Specification TECHNICAL SPECIFICATION FOR AN ESSENTIAL Version: 3 Issued: 14 October 2016 Owner: Chief Engineer Approved By: Andrew Russack Head of Engineering - Electrical PRINTOUT MAY NOT
More informationPower Cables and their Application
Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,
More informationTitle Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)
Discipline Engineering Standard NSW Category Electrical Title Substation Auxiliary Transformer from Rectifier Transformer Secondary Reference Number PDS 01 (RIC Standard: EP 05 00 00 01 SP) Document Control
More informationDevice Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.
/9 TECHNICAL SPECIFICATIONS VOLTAGE LOW-POWER TRANSFORMER VS- Rev. Date Revision Description Prepared by Checked by Approved by 0 24/09/2 First issue A. Peretto L. Peretto 24/06/6 All text review E. Scala
More informationAbout us. Vision. To lead our field in innovation, quality and customer service.
a Index 1 2 4 6 7 8 13 About us Low voltage switchgear & bus duct Medium voltage switchgear & bus duct UKAS ACCREDITATION ASTA RECOGNITION Distribution and Power transformers OUR TEAM About us Vision To
More informationUBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations 1.2 Description.1 UBC requirements for Substation Transformers. 2.0 MATERIAL AND DESIGN REQUIREMENTS
More informationa Nexans company Catalogue 2012
a Nexans company Catalogue 0 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable
More informationMeasuring current transformers of the W, W series
Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000
More informationsave energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers
save energy, it is precious Mfg. of all types of Distribution / Power & Furnace Transformers SYNERGY transformers SAFETY AND EFFICIENCY, COMBINED WITH LONG-TERM RELIABILITY, ARE THE HALLMARKS OF WORLD-RENOWNED
More informationAdvanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) CP RC Resonance circuit for GIS testing A new approach to testing gas-insulated switchgear Testing gas-insulated switchgear
More informationSGB at a glance. One of the leading manufacturers. for transformers worldwide
SGB at a glance One of the leading manufacturers SGB Regensburg for transformers worldwide 50 kva up to 1.200 MVA turnover (2010): ~ EUR 580 million 1.309 employees Headquarters: Regensburg, Germany 5
More informationHIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24
LECTURER-24 GENERATION OF HIGH ALTERNATING VOLTAGES When test voltage requirements are less than about 300kV, a single transformer can be used for test purposes. The impedance of the transformer should
More informationBasic Principles and Operation of Transformer
Basic Principles and Operation of Transformer CONSTRUCTIONAL ASPECTS Cores In order to enhance core s magnetic properties, it is constructed from an iron and silicon mixture (alloy). The magnetic core
More information50-SDMS-01 SPECIFICATIONS FOR
SPECIFICATIONS FOR CURRENT TRANSFORMERS UP TO 36 KV This specification is property of SEC and subject to change or modification without any notice C O N T E N T S CLAUSE TITLE PAGE NO. ------------ --------
More informationMESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION
Engineering Specification Head of Electrical Engineering MESP 050100-01 TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION Version:
More informationa Nexans company Catalogue 2014
a Nexans company Catalogue 014 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More informationAM SGB Sdn Bhd. Company Profile. Transformer First Class
AM SGB Sdn Bhd Company Profile Transformer First Class Company Background AM SGB AM SGB Sdn Bhd was locally incorporated in 1994 and commenced its production in Nilai early 1996. Starkstrom Gerätebau GmbH
More informationCapacitive voltage transformers
Capacitive voltage transformers Outdoor operation Oil-paper insulated ECF (72 550) kv General description Capacitive voltage transformers of type ECF are used in high-voltage switchgears from 72 to 550
More informationPTTS series. Power Transformer Test System. Scope of Work:
PTTS series Power Transformer Test System components insure the customer years of reliable service from their transformer test system. 750kV Class Power Transformer Test Lab PTTS series power transformer
More informationPRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance
PRODUCT FOR HIGH VOLTAGE APPLICATION Current transformers for Gasinsulated switchgear type ELK Instructions for installation, use and maintenance 2 CURRENT TRANSFORMERS FOR GAS-INSULATED SWITCHGEAR TYPE
More informationResistive capacitive voltage divider
Resistive capacitive voltage divider Outdoor operation Oil-paper insulated ROF (72 550) kv General description Resistive capacitive voltage dividers type ROF ( RC divider ) are used in high voltage networks
More informationThe NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:
Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.
More informationPowered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers
Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters CURRENT TRANSFORMERS Current Transformers Analogue Panel Meters Shunts Digital Multimeters
More informationCurrent Transformers. Type OSKF
Current Transformers Type OSKF Current Transformers Introduction Trench is a recognized world leader in the design and manufacture of high voltage equipment for application on electric utility and high
More informationYour safety first! This is the reason why our manual begins with the following guidelines:
High Voltage Products Current Transformers PA 123a and PA 145a Installation and operation manual Your safety first! This is the reason why our manual begins with the following guidelines: Use the transformer
More informationPRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS
PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS n Quality made in Germany n Standardized and customized solutions n Turn key projects, all from one hand 0.1-1/1 Product Portfolio Test and Measuring Systems
More informationComparison of CAN/CSA C88.1, IEEE C /01 & IEC 60137
ITEM Power factor (tanδ) & Capacitance Measurement Dry 1-minute Power frequency with partial discharge measurement CAN/CSA C88.1-96 IEEE C57.19.00/01 IEC 60137 Requirement Requirement Requirement Clause
More informationTECHNICAL INFORMATION
Single-Phase Low Voltage Dry- Type Transformers 5-400 kva Three-Phase Low Voltage Dry- Type Transformers 7.5-1000 kva TECHNICAL INFORMATION TABLE OF CONTENTS Introduction...3 Technical Explanations...4
More informationSPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers
SPECIFICATION GUIDE ABB VACUUM CAST COIL DRY TRANFORMERS CONTENTS 1. General 1.1. Codes and standards 1.2. Service conditions 1.3. System characteristics 1.4. Documentation 2. Design and construction 2.1.
More informationPOWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.
POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products
More informationPV 123 voltage transformer Installation and operation manual
High Voltage Products PV 123 voltage transformer Installation and operation manual Your safety first! This is the reason why our instruction begins with the following guidelines: Use the transformer for
More informationT-Line, current transformers
Type HF, primary current up to 5000 amps, accuracy classes from 0.2S to 3, highest system voltage 720 volt T-Line, current transformers Catalogue 208 . Table for contents...2 2. Description Current transformers
More informationCast resin transformers HARMONY TM
Cast resin transformers HARMONY TM HARMONY TM the optimum solution for higher performance At a time when we are all seeking to preserve our way of life, the production of equipment whilst ensuring safety
More informationSubstation Preventive Maintenance
Substation Preventive Maintenance PROVINCIAL ELECTRICITY AUTHORITY 1 Presentation Contents 1) A kind of substation 2) Electrical equipment details of AIS substation 3) Electrical equipment details of GIS
More informationPES & IAS NY Chapter And NY LMAG June 23 rd, 2015
PES & IAS NY Chapter And NY LMAG June 23 rd, 2015 High Temperature Insulation Systems and their use in Mobile Transformers Myron B. Bell, PE mbell@deltastar.com Delta Star, Inc. June 23 rd 2015 Introduction
More informationSPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS
-1- INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION June 2013 SPECIFICATION No 150 kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS I. SCOPE This specification
More informationMEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers
MEDIUM VOLTAGE PRODUCT TJP 5.x Indoor voltage transformers 2 TJP 5.X INDOOR VOLTAGE TRANSFORMERS 01 Voltage transformer TJP 5.1 and TJP 5.2 with suitable fuses Parameters Highest voltage for equipment
More informationMSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA
MSR Series Modular Series Resonant Systems - 250...2200kV; kva...60,000kva The MSR Series is designed to provide power for FEATURES tests on cables, HV and EHV transformers, gasinsulated switchgear, bushings,
More informationAccessories. Accessories
Accessories Accessories Voltage transformer Voltage transformer Powerful and precise Input, 3-pole Output is 3-pole + N Use in IT networks without neutral line For reducing the measurement voltage for
More informationCAST RESIN DRY TRANSFORMER
CAST RESIN DRY TRANSFORMER Majority owned subsidiary company of ELETTROMECCANICA COLOMBO s.a.s., Italy Elettromeccanica India Elettromeccanica India Pvt Ltd (EIPL) is a joint-venture company with Elettromeccanica,
More information4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation
4. CPCITIVE VOLTGE TRNSFORMERS ND COUPLING CPCITORS 420 kv Capacitive voltage transformers. Fingrid, Visulahti (Finland). 34 Instrument transformers High voltage INTRODUCTION Capacitive voltage transformers
More informationMeasuring current transformers of the W B series
Measuring current transformers of the W B series W-B_D00075_01_D_XXEN/09.2015 Measuring current transformers of the W B series Product description Measuring current transformers of the W B series are highly
More informationProducts for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers
Products for High Voltage Application AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers Technical parameters Value Highest voltage for equipment 1.2 kv Power frequency voltage,
More informationUSER MANUAL. Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications
USER MANUAL Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications Models: BMOD0125 P064 B02 BMOD0094 P075 B02 Document #1014204 Notice: The products described
More informationCOMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS
006: 2008 CEB SPECIFICATION COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS CEYLON ELECTRICITY BOARD SRI LANKA Specification for COMBINED METERING TRANSFORMERS (OUTDOOR TYPE) FOR
More informationMEDIUM & HIGH VOLTAGE
MEDIUM & HIGH VOLTAGE TESTING EQUIPMENT VOLTAGE WITHSTAND SGM Series Resonant Systems The SGM series are used for generating high AC voltages at a fixed frequency (mainly 50 or 60 Hz) by means of an excited
More informationTransformers Contents Page
Transformers Contents Page Introduction... / Product Range... / Electrical Design... / Transformer Loss Evaluation... / Mechanical Design... / Connection Systems... / Accessories and Protective Devices...
More informationHigh voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS
High voltage shunt capacitor banks Alstom Grid high voltage shunt capacitor bank offering is divided in: By bank construction HV open rack capacitor banks HV enclosed capacitor banks By bank design HV
More informationMEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers
MEDIUM VOLTAGE PRODUCT TJP 6.1, TJP 6.2 Indoor voltage transformers 2 TJP 6.1, TJP 6.2 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning
More informationChapter 2 High Speed Machining
Chapter 2 High Speed Machining 1 WHAT IS HIGH SPEED MACHINING (HSM)??? Low Speed High Speed 2 Defined as the use of higher spindle speeds and axis feed rates to achieve high material removal rates without
More informationDescription. Features and Benefits
KA-108 The General Electric Type KA-108 Bushing Potential Device is a reliable, safe, economical voltage transforming device for the operation of instruments and relays from high-voltage circuits, 115
More informationSPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)
SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) 0.415/33kV DESIGN AND CONSTRUCTION General 1. The transformer shall be three phase, oil immersed type, air cooled, core type, outdoor
More informationUnderground System Design TADP 547
Underground System Design TADP 547 Industry Standards, Specifications and Guides Presentation 6.4 Instructor: Frank Frentzas Industry Organizations Several professional organizations develop standards
More informationFlexibility and efficiency on high accuracy machining
Permanent-electro magnetic systems for turning and vertical grinding Flexibility and efficiency on high accuracy machining No piece distortion or deformation Uniform clamping: minimized vibrations Complete
More informationMechanical Design. Brian Brinson Mechanical Design Manager.
Mechanical Design Brian Brinson Mechanical Design Manager brian.brinson@spx.com September 26, 2018 Agenda 1. Design Process 2. Pre-Approval Drawings Bid Drawings Preliminary Drawings 3. Approval Package
More informationVacuum Interrupters for Medium Voltage
for Medium Voltage Reliable, Maintenance-Free and Environmentally Friendly Today, vacuum as an arc extinguishing medium provides the most cost-effective solution for medium-voltage circuit-breakers. Siemens
More informationCONTENTS 2/ /7 8/9 10/11 12/13 14/15 16/17 18/19 20/21 22/23 24/25 26/27 28/29 30/31 32/ Contact Us 38
CONTENTS Market Sectors Company Profile Planar Technology Product Range Overview Size 10 MAX 1kW Size 195 MAX 1.5kW Size 225 MAX 2kW Size 20 MAX 2kW Size 50 MAX 6.5kW Size 500 MAX 10kW Size 510 MAX 10kW
More informationMEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017
MEDIUM VOLTAGE TERMINATIONS CATALOGUE 01 NEXANS NETWORK SOLUTIONS DIV. EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More information