1 -156 Purpose & Industrial Control Purpose (1000 kva and Below) mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. shall be manufactured by Eaton. shall be designed, manufactured and IEEE standards. All 0-volt class transformers through 1000 kva shall be UL listed and bear the UL label. shall be designed for for 24 hours a day, 3 days a year operation, with normal life expectancy as defined in ANSI C.6. shall be insulated as follows: Type EP or EPT: 0.0 through 75 kva: 185 C Type DS-3 or DT-3: 15 kva and above: 220 C (Class R) indicated temperature rise in a C average over 24 hours. Test Method D5. compressed. Coils shall be wound of and continuous wound construction. BIL (Basic Impulse Level) for all 0- volt class windings shall be 10 kv. Cutler-Hammer Family of Dry-Type Distribution On encapsulated units rated [75 kva and below] [15 kva and below] [ kva and below] the core and coil assembly shall be completely encapsulated in a proportioned mixture of resin and aggregate to provide a moistureproof, shock resistant seal. The core and coil encapsulation system shall minimize the sound level. On ventilated units rated [15 kva and above] [30 kva and above] [112.5 kva and above] the core and coil assembly shall be impregnated with nonhygroscopic, thermosetting varnish and cured to reduce hot spots and seal out moisture. The assembly shall be installed gauge steel and shall be finished utilizing a continuous process of degreasing, cleaning and phosphatizing, of a thermosetting polyester powder coating and subsequent baking. The coating color shall be ANSI and shall be UL recognized for outdoor use. The maximum temperature exceed 0 C. [15 kva and below] [ kva and below] encapsulated the enclosure construction shall be totally enclosed, nonventilated, NEMA 3R, with lifting provisions. On units rated [15 kva and above] [30 kva and above] [112.5 kva and above] the enclosure construction shall be ventilated, NEMA 2, dripproof, with lifting provisions. All ventilation openings shall be protected against falling dirt. On outdoor units, provide suitable weathershields over ventilation openings. To ensure proper ventilation, locate the unit at least 6 inches (152.4 mm) from the adjacent wall Table Average on the rated voltage

2 Purpose & Industrial Control -1 Dry-Type for Non-Linear Loads Furnish and install, individually mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. shall be manufactured by Eaton. shall be designed, manufactured, and tested in accordance with all the latest applicable ANSI, NEMA and IEEE standards. All 0-volt class transformers through 0 kva shall be UL listed as suitable for non-sinusoidal current loads with K factor not to exceed [4] [13] [20]. shall be insulated with a UL recognized 220 C (Class R) insulation system. Winding temperature rise shall be (80 C) (115 C) (1 C). indicated temperature rise in a C average. Test Method D5. compressed. Transformer coils shall be wound of conductor with continuous wound construction. An electrostatic shield consisting of a single turn of aluminum shall be placed between the primary and secondary winding and grounded to the transformer core. BIL (Basic Impulse Level) for all 0-volt class windings shall be 10 kv. The neutral conductor shall be rated to carry 200% of normal phase current. Table Average of a polymer polyester powder coating and baking. The coating color shall be ANSI and shall be UL recognized for outdoor use. The maximum temperature exceed 0 C. openings shall be protected against falling dirt. On outdoor units, provide suitable weathershields over ventilation openings. To ensure proper ventilation, Non-Linear Ratings The transformers shall be specifically designed to supply circuits with a harmonic profile equal to or less than a K Factor of 4 or 13 as described below without exceeding [80 C] [115 C] [1 C] temperature rise. Table Non-Linear Ratings Harmonic K-4 K-13 Fundamental 3rd 5th 7th th 11th 13th 15th 17th 100.0% 34.0% 22.0% 1.0%.7%.5%.3%.3% 100.0% 70.0% 42.0% 5.0% 1.0%.7%.6% on the rated voltage Further Information B.36B.01.S.E Product Specification Guide..... Section 1

3 -1 Purpose & Industrial Control Low Temperature Rise Energy Efficient Furnish and install, three-phase low temperature rise energy efficient drytype transformers of the two-winding type, self-cooled, with ratings (kva) as indicated on the drawings. shall be manufactured by Eaton. shall be designed, manufactured, all applicable ANSI/NEMA and IEEE standards, and shall be listed by Underwriters Laboratories, Inc. and bear the UL label. shall be designed for 24 hours a day, 3 days a year, with normal life expectancy as defined in ANSI C.6. Insulation System and Temperature Rise shall be insulated with a 220 C (Class R) shall be 115 C rise (80 C rise) and shall be capable of carrying a 15% continuous overload, (80 C rise transformers a continuous 30% overload) without exceeding a 1 C rise. Required performance shall be obtained without exceeding the above rise in a C maximum, 30 C average ambient temperature. Test Method D5. losses. Maximum magnetic flux densities shall be substantially below the saturation point. The core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Coils shall be wound of electrical grade [aluminum] [copper] with continuous wound construction. BIL (Basic Impulse Level) for all 0-volt class windings shall be 10 kv. of a polymer polyester powder coating and subsequent baking. The coating color shall be ANSI and shall be UL recognized for outdoor use. falling dirt. To ensure proper ventilation, All transformers shall be equipped with a wiring compartment suitable for conduit entry and large enough to allow convenient wiring. The maximum temperature on top of the enclosure shall not exceed 0 C. shall not exceed the following ANSI/NEMA levels for self-cooled Table Average on the rated voltage Product Specification Guide..... Section 1

4 Purpose & Industrial Control -15 Isolation with Electrostatic Shielding mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. shall be manufactured by Eaton. shall be designed, manufactured, and IEEE standards. All 0-volt class transformers through 1000 kva shall be UL listed and bear the UL label. shall be designed for for 24 hours a day, 3 days a year operation, with normal life expectancy as defined in ANSI C.6. shall be insulated as follows: Type EP or EPT: 0.0 through 75 kva: 185 C insulation system which superseded Class F, based on 115 C rise. Type DS-3 or DT-3: 15 kva and above: 220 C (Class R) insulation system which superseded Class H, based on 1 C rise. indicated temperature rise in a C maximum ambient. Test Method D5. losses. Maximum magnetic flux densities shall be substantially below the saturation point. The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Transformer coils shall be wound of electrical grade aluminum and continuous wound construction. An electrostatic shield consisting of a single turn of [aluminum] [copper] shall be placed between the primary and secondary winding and grounded to the transformer core. BIL (Basic Impulse Level) for all 0-volt class windings shall be 10 kv. [15 kva and below] [ kva and below] the core and coil assembly shall be completely encapsulated in a proportioned mixture of resin and aggregate to provide a moistureproof, shock resistant seal. The core and coil encapsulation system shall minimize the sound level. On units rated [15 kva and above] [30 kva and above] [112.5 kva and above] the core and coil assembly shall be impregnated with nonhygroscopic, thermosetting varnish and cured to reduce hot spots and seal out moisture. The assembly shall be installed of a thermosetting polyester powder coating and baking. The coating color shall be ANSI and shall be UL recognized for outdoor use. The maximum temperature on top of the enclosure shall not exceed 0 C. [15 kva and below] [ kva and below] encapsulated, the enclosure construction shall be totally enclosed, nonventilated, NEMA 3R, with lifting provisions. On units rated [15 kva and above] [30 kva and above] [112.5 kva and above] the enclosure construction shall be falling dirt. On outdoor units, provide suitable weathershields over ventilation openings. To ensure proper ventilation, Table Average on the rated voltage

5 -1 Purpose & Industrial Control Typical Specification ac Adjustable Frequency Drive Isolation mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages for input application as indicated on the drawings. shall be manufactured by Eaton. shall be designed, manufactured, and IEEE standards. All 0-volt class transformers through 5 kva shall be UL listed and bear the UL label. shall be designed for for 24 hours a day, 3 days a year operation, with normal life expectancy as defined in ANSI C.6. shall be insulated with a UL recognized 220 C (Class R) indicated temperature rise in a C average over 24 hours. Test Method D5. compressed. Coils shall be wound of and continuous wound construction. BIL (Basic Impulse Level) for all 0- volt class windings shall be 10 kv. A temperature sensing device shall be imbedded in the center coil. of a thermosetting polyester powder coating and subsequent baking. The coating color shall be ANSI and shall be UL recognized for outdoor use. The maximum temperature exceed 0 C. falling dirt. To ensure proper ventilation, On outdoor units, provide suitable weathershields over ventilation openings. Table -18. Average The following table lists the recommended kva size of the drive isolation transformer for a specific horsepower requirement. Table -10. Three-Phase Horsepower ac Motor kva Minimum Product Specification Guide..... Section 1

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description General-Purpose Encapsulated.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Catalog Selection................ Product Selection....................... Single-Phase..........................

More information

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS SECTION 16461C - DRY TYPE TRANSFORMERS PART 1 - GENERAL 1.1 This section includes design and performance requirements for dry-type transformers rated for use on secondary distribution systems rated 600

More information

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description General-Purpose Encapsulated.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Catalog Selection................ Product Selection....................... Single-Phase..........................

More information

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description General-Purpose Encapsulated Transformers.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Transformers Catalog Selection................ Product Selection....................... Single-Phase..........................

More information

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide MGM Transformer Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide MGM Transformer Company 5701 Smithway Street Commerce, CA 90040 www.mgmtransformer.com Phone: 323.726.0888

More information

2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description

2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description Distribution.5 Contents Description Motor Drive Isolation............ Mini Power Centers Standards and Certifications............... Catalog Number Selection................ Product Selection.......................

More information

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class GE Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial

More information

P48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center

P48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 P48G11S05P 5KVA 1PH 480V - 10/40V Mini Power Center Eaton Corp Catalog Number Manufacturer Description Weight per unit

More information

Technical Data and Specifications. Core and Coil Assemblies

Technical Data and Specifications. Core and Coil Assemblies February 2007 Technical Data and Specifications -161 Typical Specifications Mini-Power Centers (3 30 kva) General Furnish and install, single-phase and three-phase general purpose individually mounted

More information

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer PANELMDP Main Distribution Panel Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Product Type PANELMDP Eaton Corp 1.0 (lbs/each) Three Phase Energy Efficient

More information

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers .5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings

More information

2.1. Product Description

2.1. Product Description .1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions........... Standards and Certifications............... Catalog Selection................

More information

Steps for Selecting the Proper Transformer

Steps for Selecting the Proper Transformer SECTION I Page 4 Steps for Selecting the Proper Transformer SINGLE PASE LOADS 1. Determine electrical load A. Voltage required by load. B. Amperes or KVA capacity required by load. C. Frequency in z (cycles

More information

T S 15KVA 1PH 240/480 Transformer

T S 15KVA 1PH 240/480 Transformer 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T2535173S 15KVA 1PH 240/480 Transformer Acme Electric Catalog Number Manufacturer Description Weight per unit Product

More information

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 S10N06P0P KVA 1PH 10/40V 16/3V Buck Boost Transformer Eaton Corp Catalog Manufacturer Description Weight per unit Product

More information

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS Acme offers a large selection of Dry-Type Distribution Transformers. Ranging from 600 Volt and below, in both Single and Three Phase, you re sure to find

More information

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE SUBSTATION TRANSFORMERS DRY-TYPE PART 1 GENERAL 1.01 1.02 1.03 1.04 SCOPE The Contractor shall furnish and install the primary and/or secondary substation transformers as specified herein and as shown

More information

Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated

Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated Catalog 7400CT1001 2010 Class 7400 CONTENTS Description.............................................

More information

Dry-Type Transformers

Dry-Type Transformers Dry-Type Transformers 600 Volt Class Bulletin 7700-99 ISO 9002 Registered 1 Federal Pacific Federal Pacific History During 1987, the Electro-Mechanical Corporation acquired the dry-type transformer division

More information

Energy Efficient Distribution Transformers

Energy Efficient Distribution Transformers Energy Efficient Distribution Transformers Established in 1917, Hammond Power Solutions Inc. (HPS), is an industry leader in magnetic transformer design and development. With our headquarters in Guelph,

More information

What is a Transformer?

What is a Transformer? What is a Transformer? Transformers are completely static electrical devices which convert alternating current from one voltage level to another. General purpose transformers are rated 600 volts and below

More information

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers INTERNATIONAL TRANSFORMERS Acme Electric s broad selection of CSA energy efficient transformers International Transformers What is CSA C802.2 Compliant? On January 1, 2005, the Canadian Energy Efficiency

More information

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

Dry Type Transformers Full Line Catalog. jeffersonelectric.com Dry Type Transformers Full Line Catalog jeffersonelectric.com The Transformer Authority PIONEER TRANSFORMERS: Why us? Scale We produce over 100,000 transformers every year. With this high level of production

More information

Power Processor - Series 700F 10KVA to 150KVA

Power Processor - Series 700F 10KVA to 150KVA Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines

More information

LVGP. Advanced transformers built for the industrial environment. Catalog: LVGP-16C-English. By Micron Power Delivery. Supersedes: LVGP-16B-English

LVGP. Advanced transformers built for the industrial environment. Catalog: LVGP-16C-English. By Micron Power Delivery. Supersedes: LVGP-16B-English LVGP By Micron Power Delivery Advanced transformers built for the industrial environment Catalog: LVGP-16C-English Supersedes: LVGP-16B-English Table of Contents Low Voltage General Purpose Transformers

More information

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1 GENERAL: The scope of this document is to provide instruction for the installation and testing of Medium Voltage, 3 Phase, Pad Mounted Transformers installed at the University of Missouri. Preferred transformers

More information

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) 0.415/33kV DESIGN AND CONSTRUCTION General 1. The transformer shall be three phase, oil immersed type, air cooled, core type, outdoor

More information

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R 75 kva Isolation Transformer 4160V Delta Primary Voltage 480Y/277 Secondary Voltage NEMA 3R Part #: MTISX3P4160D75KVA480Y.277N3R Page: 1 The MTISX3P4160D75KVA480Y.277N3R 4160D 3 Phase Energy Efficient

More information

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

INSTALLATION, OPERATION AND MAINTENANCE GUIDE INSTALLATION, OPERATION AND MAINTENANCE GUIDE FOR INDOOR/OUTDOOR SINGLE PHASE ENCAPSULATED TRANSFORMERS Indoor/Outdoor Encapsulated Transformers The pictures used in this guide are only a representation

More information

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI GENERAL: The scope of this document is to provide instruction for the installation and testing of Medium Voltage, 3 Phase, Pad Mounted Transformers installed at the University of Missouri. Preferred transformers

More information

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL SINGLE PHASE INSTRUCTION MANUAL DIAGRAM D This manual applies to all single-phase buck & boost transformers sold by Larson Electronics. Please refer to the connection diagram on pages 4-6 for properly

More information

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor 500 kva Dry-type Isolation Transformer - 13200V-Delta to 208Y/120V 3PH - NEMA 1/Indoor Part #: MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Page: 1 The MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Dry-type Isolation

More information

SECTION TRANSFORMERS

SECTION TRANSFORMERS SECTION 16460 - TRANSFORMERS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Section

More information

Jefferson Electric Inc Product Catalog JE901

Jefferson Electric Inc Product Catalog JE901 Jefferson Electric Inc Product Catalog JE901 Worldwide Products and Services Tradition of Excellence Jefferson Electric has been a pioneer and innovator of magnetic products since 1915. We enjoy a rich

More information

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING 1.0 General This specification covers the electrical characteristics and general

More information

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R 75 kva Isolation Transformer 480V Delta Primary 208V Delta Secondary NEMA 3R Part #: MTDOE163P480D75KVA208DN3R Page: 1 The MTDOE163P480D75KVA208DN3R 480D 3 Phase Energy Efficient Isolation Transformer

More information

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016) Typical Specification 1.2kV Class Energy Efficient Dry-Type Distribution Transformers Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016) Canada 595 Southgate Drive Guelph, Ontario N1G

More information

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1. TECHNICAL SPECIFICATIONS for Single Phase, 1 to 3 KVA Power Conditioner with Regulation and Distribution Constant Power 3 (CP3) CP36508A 7/15/04 1.0 General This specification covers the electrical characteristics

More information

Transformer Questions & Answers

Transformer Questions & Answers Transformer Questions & Answers. What is a transformer and how does it work? A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. It can be designed

More information

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers SPECIFICATION GUIDE ABB VACUUM CAST COIL DRY TRANFORMERS CONTENTS 1. General 1.1. Codes and standards 1.2. Service conditions 1.3. System characteristics 1.4. Documentation 2. Design and construction 2.1.

More information

15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R

15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R 15 kva Isolation Transformer Single Phase 208V Primary 120/240V Secondary NEMA 3R Part #: MT20815KVA240.120 Page: 1 The MT20815KVA240.120 208V 1 Phase Energy Efficient Isolation Transformer from Larson

More information

Transformer Questions & Answers

Transformer Questions & Answers Transformer Questions & Answers. What is a transformer and how does it work? A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. It can be designed

More information

ULTRA-K Series 600K - he

ULTRA-K Series 600K - he 5 kva 500 kva ULTRA-K Series 600K - he High Efficiency K-Rated Power Conditioning Transformers Designed to be used with linear or non-linear loads. Applications: Audio / Video Recording Equipment IT Systems

More information

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R 10 kva Transformer 480V Primary Voltage 208V Secondary Voltage Single Phase NEMA 3R Part #: MTATX1P480V10KVA208VN3R Page: 1 The MTATX1P480V10KVA208VN3R 480V 1 Phase Energy Efficient Encapsulated Transformer

More information

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase 80 kva Isolation Transformer 480V AC Primary 20V AC Secondary NEMA 3R Single Phase Part #: MTDOE161P480V80KVA20VN3R The MTDOE161P480V80KVA20VN3R 480V AC 1 Phase Energy Efficient Isolation Transformer from

More information

HPS Universal BUCK-BOOST TRANSFORMERS

HPS Universal BUCK-BOOST TRANSFORMERS BUCK-BOOST TRANSFORMERS Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R 500 kva Isolation Transformer 480V Delta Primary 400Y/231 Wye Secondary NEMA 3R Part #: MTDOE163P480D500KVA400Y.231N3R Page: 1 The MTDOE163P480D500KVA400Y.231N3R 480 V Delta 3 Phase Energy Efficient Isolation

More information

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards Buck-Boost 9 0 VA to 10 Applications n A comprehensive line of transformers for low voltage applications. n Economical for stepping voltages up or down n Solve over/under voltage problems efficiently n

More information

K Factor Power Transformers

K Factor Power Transformers Ashley-Edison AsiaElectricTransformers (UK) K Factor Power Transformers DTKF series Low Voltage Dry Type K Factor Power Transformers AET-DTKF-2004-01: Page 1 Asia Electric Transformers, Entrepreneur Business

More information

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

Dry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION

Dry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION NON-LINEAR TRANSFORMER PRESENTATION 1 PROBLEM: HARMONICS CAUSE EXCESSIVE TRANSFORMER HEATING Increased Losses Proximity Skin Effect Stray Losses Circulating Effect Triplen Harmonics Add in Neutral Increased

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

TRANSFORMER COM PANY. Dry Type Substation Transformers

TRANSFORMER COM PANY. Dry Type Substation Transformers TRANSFORMER COM PANY Dry Type Substation Transformers Special Design MGM Transformer Company manufactures transformers in six major categories: Special Design Dry Type Transformers: 9 kva to 10,000 kva

More information

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A

More information

Reactor and inductor are names used interchangeably for this circuit device.

Reactor and inductor are names used interchangeably for this circuit device. Recommended Design Criteria for Air-Cooled Reactor for Line and Track Circuits Revised 2015 (7 Pages) A. Purpose This Manual Part recommends design criteria for an air-cooled reactor for line and track

More information

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz 7.5 kva Isolation Transformer 460V Primary 230V Secondary NEMA 3R Single Phase 50/60 Hz Part #: MTISX1P460V7.5KVA230VN3R50.60HZ Page: 1 The MTISX1P460V7.5KVA230VN3R50.60HZ 460V 1 Phase Energy Efficient

More information

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.

More information

Low Voltage Transformers. Selection Guide

Low Voltage Transformers. Selection Guide Low Voltage Transformers Selection Guide Special Purpose Transformers Non-Ventilated Transformers For use in contaminated or dust-laden environments, indoor or outdoor. Export Model Transformers Designed

More information

ADVANTAGE OIL-COOLED LINE

ADVANTAGE OIL-COOLED LINE CATHODIC PROTECTION RECTIFIER SPECIFICATION ADVANTAGE OIL-COOLED LINE INTEGRATED RECTIFIER TECHNOLOGIES, INC. 15360 116 Avenue, Edmonton, Alberta, Canada T5M 3Z6 Phone: (780) 447-1114 Fax: (780) 454-0004

More information

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013) S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013) 1.0 GENERAL 1.1 This specification covers the electrical and mechanical

More information

Amveco Toroidal Solutions. Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications.

Amveco Toroidal Solutions. Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications. Amveco Toroidal Solutions Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications. AMVECO TOROIDAL SOLUTIONS Acme Electric s Amveco brand specializes

More information

Your Presenters. > Thomas Patzner Product Manager, Low Voltage Transformers. > Marquette University Electrical Engineering. > Apprentice Electrician

Your Presenters. > Thomas Patzner Product Manager, Low Voltage Transformers. > Marquette University Electrical Engineering. > Apprentice Electrician Your Presenters > Thomas Patzner Product Manager, Low Voltage Transformers > Marquette University Electrical Engineering > Apprentice Electrician > Low Voltage Transformers - Co-op (Square D Company) (lab

More information

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian) PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian) 1.0 General This specification covers the electrical characteristics and

More information

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R 5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R Part #: MT-ISX-FP-1P-115V-5KVA-230V-N3R Page: 1 The MT-ISX-FP-1P-115V-5KVA-230V-N3R 115V 1 Phase Energy

More information

BUCK-BOOST TRANSFORMERS

BUCK-BOOST TRANSFORMERS Hammond Power Solutions Inc. Page of Buck-boost transformers represent an economical way to both raise supply voltage caused by line drop or equipment demand on the distribution system; or lower voltage

More information

DTS ISOLATION TRANSFORMER SPECIFICATIONS

DTS ISOLATION TRANSFORMER SPECIFICATIONS 1.1 Scope of Work: DTS ISOLATION TRANSFORMER SPECIFICATIONS The DTS transformers shall be designed to supply isolated power to sensitive computer based equipment. The DTS units will meet or exceed the

More information

Full Line Product Catalog

Full Line Product Catalog Full Line Product Catalog TC Table of Contents Dry-Type Distribution Transformers Transformer Questions and Answers 6-13 Enclosure Definition 13 Steps in Transformer Selection 14-17 Construction Features

More information

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS PURCHASE SPECIFICATIONS OF 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS SPECIFICATION NO. : OR12423 REVISION NO. : Rev 00 DATE : 01.03.2011 DISTRIBUTION : PI - 4 copies O/C - 1 copy PREPARED BY

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R

225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R 225 kva Autotransformer 240V Delta Primary Voltage 220V Delta Secondary Voltage NEMA 3R Part #: MTATX3P240D225KVA220DN3R Page: 1 The MTATX3P240D225KVA220DN3R 240D 3 Phase Energy Efficient Autotransformer

More information

Howard Smart Transformer Specification Guide

Howard Smart Transformer Specification Guide Howard Smart Transformer Specification Guide General Requirements Overhead pole-type smart distribution transformers shall be single phase, 60 Hz, mineral-oil filled and self-cooled and shall conform as

More information

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design

More information

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer PART 1: GENERAL 1.01 Transformer A. This section includes liquid filled, pad mounted distribution transformers with primary voltage of 12kV or 4.16kV (The University will determine primary voltage), with

More information

Full Line Product Catalog

Full Line Product Catalog Full Line Product Catalog E L E C T R I C A L TABLE OF CONTENTS SECTION 1 SECTION 2 SECTION 3 Dry-Type Distribution Transformers Transformer Questions & Answers... 6-10 Selection Steps... 11-12 Construction

More information

Power-Sure 700. Technical Data TD158001EN. Contents

Power-Sure 700. Technical Data TD158001EN. Contents Technical Data TD158001EN Power-Sure 700 Supersedes August 2015 Contents Description Page General description... 2 Power-Sure 700 benefits.... 2 Specifications... 3 Industry standards and certifications...

More information

B. Manufacturers: Square-D, G.E. or Westinghosue.

B. Manufacturers: Square-D, G.E. or Westinghosue. SECTION 16470 - PANELBOARDS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description: OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description: VTOP 2(1) X Dry Insulated voltage transformer (VT) There are two designs of this voltage transformers: - VTOP 1-X single phase, dry insulated

More information

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations 1.2 Description.1 UBC requirements for Substation Transformers. 2.0 MATERIAL AND DESIGN REQUIREMENTS

More information

Description. Features and Benefits

Description. Features and Benefits KA-108 The General Electric Type KA-108 Bushing Potential Device is a reliable, safe, economical voltage transforming device for the operation of instruments and relays from high-voltage circuits, 115

More information

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers Power Quality 13 Answering Today s Power Challenges Jefferson Electric is continually updating its product line to remain on the forefront of transformer technology. Electrical harmonics have become a

More information

Component Requirement Specification for SGI 500XT Isolation Transformer

Component Requirement Specification for SGI 500XT Isolation Transformer REVISION CONTROL REV. DESCRIPTION DATE APPROVED A Initial release 01/21/13 M.Hale B Allowance f low voltage Wye w/ insulated neutral. 04/10/13 M.Hale C Secondary Configuration added. Added Primary Configuration

More information

Section 2 Outdoor Voltage Transformers

Section 2 Outdoor Voltage Transformers Section 2 Outdoor Voltage Transformers GE Meter 130 Main St., Somersworth, NH 03878 USA & Canada: (800) 626-2004 Fax: (518) 869-2828; GE Worldwide: (518) 869-5555 2-1 120 V to 600 V BIL 10 kv Outdoor Voltage

More information

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK PART 1.0 GENERAL 1.1 SCOPE A. This specification contains the minimum requirements for the design, manufacture and testing of a UL listed,

More information

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R 1.5 kva Single Phase Transformer 120V Primary Voltage 277V Secondary Voltage NEMA 3R Part #: MT120V1.5KVA277V Page: 1 The MT120V1.5KVA277V 120V 1 Phase Energy Efficient Transformer from Larson Electronics

More information

Basic Principles and Operation of Transformer

Basic Principles and Operation of Transformer Basic Principles and Operation of Transformer CONSTRUCTIONAL ASPECTS Cores In order to enhance core s magnetic properties, it is constructed from an iron and silicon mixture (alloy). The magnetic core

More information

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A Group F : No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS Table : A No. Description 1. Make & Manufacturer 2. Place of Manufacturer 3. Voltage Ratio 4. Rating

More information

Liquid-Filled Transformers

Liquid-Filled Transformers Liquid-Filled Transformers Custom Transformers at Standard Prices NIAGARA TRANSFORMER CORP. Induction Furnace Transformer Cycloconverter Rectifier Duty Transformer Arc Furnace Transformer Full Range of

More information

Federal Pacific Engineered and Specialty Transformer Catalog

Federal Pacific Engineered and Specialty Transformer Catalog Federal Pacific Engineered and Specialty Transformer Catalog Federal Pacific History In 1987, Electro-Mechanical Corporation acquired the dry-type transformer division of Federal Pacific Electric in Des

More information

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3 CONTENTS COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3 CONSTRUCTION... 4 ~ 5 A. CORE AND FRAME... 4 B. COIL... 5 C. TEMPERATURE INDICATOR... 5 CHARACTERISTICS... 6 MANUFACTURING FACILITIES...

More information

Acme Electric Full Line Product Catalog

Acme Electric Full Line Product Catalog Acme Electric N85 W12545 Westbrook Crossing Menomonee Falls, WI 53051 800.334.5214 acmepowerdist.com Acme Electric Full Line Product Catalog Full Line Product Catalog Today, Actuant Electrical provides

More information

Drive Isolation Transformers

Drive Isolation Transformers Drive Isolation Transformers The Acme Drive Isolation Transformers are specifically designed to accommodate the special voltages and kva sizes unique to AC and DC motor drive applications. DRIVE ISOLATION

More information

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator) PRODUCT SPECIFICATION FOR A 15 THRU 500 kva, THREE PHASE, MODULAR POWER REGULATOR AND CONDITIONER PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator) 1.0 General This specification covers the electrical

More information

Substation transformers

Substation transformers Substation transformers Triplex Indoor Power Centers Functional specification guide Functional specification for Triplex Indoor Power Centers (IPC) 750 2500 kva 1.0 Scope 1.1. This specification covers

More information

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable: Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.

More information

Ritz Instrument Transformers GmbH. Welcome

Ritz Instrument Transformers GmbH. Welcome Ritz Instrument Transformers GmbH Welcome About Ritz together with over 200 years of experience in instrument transformer production since 1945 since 1945 since 1945 since 1904 RITZ Group - Organization

More information

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers KNOW MORE ABOUT THE TRANSFORMERS Glossary Transformers Ambient temperature The existing temperature of the atmosphere surrounding a transformer installation. Ampere The practical unit of electric current.

More information

Custom Power Supplies, Transformers, Chokes & Reactors

Custom Power Supplies, Transformers, Chokes & Reactors Y O U R P O W E R S O U R C E Custom Power Supplies, Transformers, Chokes & Reactors The Neeltran Story Transformers and Power Supplies Industry Leader since 1973 Neeltran has become the most reliable

More information

Low Pass Harmonic Filters

Low Pass Harmonic Filters Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power

More information

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs VIRGINIA TRANSFORMER CORP Individual solutions from a global perspective Drive & Rectifier Transformersrs Oil Drilling Paper Mill Virginia Transformer Commitment to our Customers Industry s Shortest Production

More information

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED Dial : (033)2677-5835 & 2667-8358 Tele Fax : (033)2667-8358 Manufacturer of Dry Type Transformers E-mail : unimag111@gmail.com Office & Factory : 26/5, Sarat Chatterjee Road, Howrah 711 104, West Bengal,

More information