Drive Isolation Transformers
|
|
- Lawrence Cain
- 5 years ago
- Views:
Transcription
1 Drive Isolation Transformers The Acme Drive Isolation Transformers are specifically designed to accommodate the special voltages and kva sizes unique to AC and DC motor drive applications.
2 DRIVE ISOLATION TRANSFORMERS The Acme Drive Isolation Transformers are specifically designed to accommodate the special voltages and kva sizes unique to AC and DC motor drive applications. Why use a Drive Isolation Transformer? Motor drives are popular because they are easy to control and help save energy. The basic motor drive uses a rectifier, made up of diode bridges or silicon controlled rectifiers (SCR), to convert AC to DC. In three-phase circuits, there is a brief moment when more than one SCR is on at the same time creating a momentary short. This short puts stress on the upstream transformer and causes a distorted voltage waveform, which can have a damaging effect on the transformer itself and electrical equipment connected to the circuit. What is a Drive Isolation Transformer? The Acme Drive Isolation Transformers are specifically designed to handle the mechanical stresses, voltage distortions, and harmonics associated with AC and DC variable speed drives. Acme s Drive Isolation Transformers maximize the power quality benefits gained from standard isolation transformers by: Preventing overheating due to harmonics Limiting harmonic peaks Increasing the ground fault tolerance of connected variable frequency drives Minimizing the transfer of inverter switching noise ACME ADVANTAGE Wound Cores and Strip Winding mean lower losses All Acme DITs above 7.5 kva are wound with strip windings to ensure the lowest possible eddy current losses. All our DITs 440 kva and larger use stacked core. This superior design has very low losses and quiet operation. Both of these features combine to significantly reduce losses and operating costs compared to other types of constructions. Copper terminations provide trouble-free operation All Acme DITs up to and including 0 kva have copper terminations. The transition from aluminum strip coil conductors to copper terminations is accomplished by a bonding process known as Koldwelding. This process has been used by Acme for over 5 years to provide a trouble-free, permanent bonding of the two metals. Stress relief Acme uses strip conductors (above 7.5 kva) instead of wire for a DIT series that easily accommodates the severe electrical and mechanical stresses found in today s AC & DC motor drives. The inherent excellent line isolation of these transformers is further enhanced with the extra protection of Acme s Electrostatic Shield free in all H.P. DIT s. kva Lower losses The harmonic currents generated by AC & DC drives increase eddy current losses (heat) in transformer windings. The thicker the winding conductor, the greater the losses. Acme uses one turn per layer of thin strip conductor which provides lower eddy current losses than comparable wire wound units. Lower losses = cooler operation and longer transformer life. Reduced short circuit forces Strip windings minimize axial short circuit forces that can cause mechanical displacement of the windings under fault conditions. For extra protection all designs 7.5 kva and above use primary and secondary coils of equal axial length. This feature tends to negate axial short circuit forces, further improving transformer life expectancy
3 Features n UL Type R Enclosures with Weather Shield on Ventilated Units (above 0 kva). Type Enclosure without weather shield. UL Listed and CSA certified kva are encapsulated, UL R. n -Phase 60 Hertz. n 80 C and 0 C insulation systems. n Encapsulated and ventilated designs. All ventilated units, are of strip wound construction. Acme s reinforced core assemblies enhance quiet operation. n Nominally 6% impedance. n Designed for use with AC, adjustable frequency or DC drives. n Full capacity taps are featured on all units. On 7.5 through 0 kva units, taps are -5% ANFC and -5% BNFC. On 7 through 880 kva units, taps are - / % ANFC and - / % BNFC. n Full range of kva ratings cover all standard drive systems. n Ample wiring compartment for easy cable entry. n Optional wall mounting brackets for certain sizes. kva 0V Delta 0Y/ Catalog Number Height Width Depth Weight (Lbs.)(Kg.) Mounting Type (Wall)(Floor) Weather Shield Dimension Drawing 7.5 DTFA7S (6) 5. (8.6) 9.5 (48.9) 7.7 (8.7) 80 (8.6) W NA F.0 DTFA0S 8.86 (48.0) 0.0 (5.6) 9.0 (.9) 65 (0.0) F NA I 4.0 DTFA04S 8.86 (48.0) 0.0 (5.6) 9.0 (.9) 65 (0.0) F NA I 0.0 DTFA00S 0.77 (5.8) 0.94 (5.) 0.8 (5.9) 45 (97.0) F NA I 7.0 DTFA074S (59) 5.48 (64.8) 4.9 (6.0) 9.40 (49.) 0 (7.0) F WSA E 4.0 DTFA044S 5.48 (64.8) 4.9 (6.0) 9.40 (49.) 0 (50.0) F WSA E 40.0 DTFA0404S 5.48 (64.8) 4.9 (6.0) 9.40 (49.) 70 (68.0) F WSA E 5.0 DTFA054S 9.40 (74.7) 8.5 (7.5).40 (56.9) 75 (70.0) F WSA E 6.0 DTFA064S 9.40 (74.7) 8.5 (7.5).40 (56.9) 495 (5.0) F WSA E 75.0 DTFA0754S 9.40 (74.7) 8.5 (7.5).40 (56.9) 55 (8.0) F WSA E 9.0 DTFA094S 5.40 (89.9).90 (8.0) 6.90 (68.) 685 (.0) F WSA E 8.0 DTFA084S 5.40 (89.9).90 (8.0) 6.90 (68.) 70 (.0) F WSA E 45.0 DTFA0454S 4.5 (05.5).90 (8.6) 9.90 (75.9) 980 (445.0) F WSA4 E 75.0 DTFA0754S 4.5 (05.5).90 (8.6) 9.90 (75.9) 0 (504.0) F WSA4 E 0.0 DTFA004S 4.5 (05.5).90 (8.6) 9.90 (75.9) 0 (508.0) F WSA4 E Optional wall mounting kits part # PL 799 Optional wall mounting kits part # PL 799 The number in ( ) s following the catalog number is the electrical wiring diagram number.
4 kva 460V Delta 0Y/ 460V Delta 460Y/66 Height Width Depth Weight (Lbs.)(Kg.) Mounting Type (Wall)(Floor) Weather Shield Dimension Drawing Catalog Number Catalog Number 7.5 DTGA7S (7) DTGB7S (4) 5. (8.6) 9.5 (48.9) 7.7 (8.7) 80 (8.6) W NA F.0 DTGA0S DTGB0S 8.86 (47.9) 0.0 (5.6) 9.0 (.9) 65 (0.0) F NA I 4.0 DTGA04S DTGB04S 8.86 (47.9) 0.0 (5.6) 9.0 (.9) 70 (.0) F NA I 0.0 DTGA00S DTGB00S 0.77 (5.8) 0.94 (5.) 0.8 (5.9) 45 (97.0) F NA I 7.0 DTGA074S (8) DTGB074S (5) 5.50 (64.8) 4.9 (6.9) 9.7 (49.) 0 (45.0) F WSA E 4.0 DTGA044S DTGB044S 5.50 (64.8) 4.9 (6.9) 9.7 (49.) 40 (54.0) F WSA E 40.0 DTGA0404S DTGB0404S 5.50 (64.8) 4.9 (6.9) 9.7 (49.) 95 (79.0) F WSA E 5.0 DTGA054S DTGB054S 9.90 (75.9) 8.5 (7.5).7 (56.8) 400 (8.0) F WSA E 6.0 DTGA064S DTGB064S 9.90 (75.9) 8.5 (7.5).7 (56.8) 550 (50.0) F WSA E 75.0 DTGA0754S DTGB0754S 9.90 (75.9) 8.5 (7.5).7 (56.8) 570 (59.0) F WSA E 9.0 DTGA094S DTGB094S 5.90 (9.).90 (8.0) 6.88 (68.) 685 (.0) F WSA E 8.0 DTGA084S DTGB084S 5.90 (9.).90 (8.0) 6.88 (68.) 765 (47.0) F WSA E 45.0 DTGA0454S DTGB0454S 4.5 (05.5).90 (8.6) 9.88 (75.9) 990 (449.0) F WSA4 E 75.0 DTGA0754S DTGB0754S 4.5 (05.5).90 (8.6) 9.88 (75.9) 00 (499.0) F WSA4 E 0.0 DTGA004S DTGB004S 4.5 (05.5).90 (8.6) 9.88 (75.9) 0 (508.0) F WSA4 E 75.0 DTGA00754S DTGB00754S (5.8) 9.50 (00.) 5.50 (90.) 090 (948.0) F WSA5 E 0.0 DTGA004S DTGB004S (5.8) 9.50 (00.) 5.50 (90.) 090 (948.0) F WSA5 G DTGB04404S (46.9) (5.6) 4.49 (05.4) 95 (04.) F WSA7 G DTGB05504S (46.9) (5.6) 4.49 (05.4) 580 (7.7) F WSA7 G DTGB06604S 6.84 (59.6) (7.) 4.49 (05.4) 700 (678.) F WSA6 G DTGB07704S 6.84 (59.6) (7.) 4.49 (05.4) 4044 (88.) F WSA6 G DTGB008804S 6.84 (59.6) (7.) 4.49 (05.4) 40 (9.7) F WSA6 G DTGB990S 6.84 (59.6) (7.) 4.49 (05.4) 485 (947.7) F WSA6 G Optional wall mounting kits-part # PL799 Optional wall mounting kits-part # PL799 The number in ( ) s following the catalog number is the electrical wiring diagram number. 4
5 kva 575V Delta 0Y/ 575V Delta 460Y/66 Height Width Depth Weight (Lbs.)(Kg.) Mounting Type (Wall)(Floor) Weather Shield Dimension Drawing Catalog Number Catalog Number 7.5 DTHA7S (40) DTHB7S (4) 5. (8.6) 9.5 (48.9) 7.7 (8.7) 80 (8.6) W NA F.0 DTHA0S DTHB0S 8.86 (47.9) 0.0 (5.6) 9.0 (.9) 65 (0.0) F NA I 4.0 DTHA04S DTHB04S 8.86 (47.9) 0.0 (5.6) 9.0 (.9) 70 (.0) F NA I 0.0 DTHA00S DTHB00S 0.77 (5.8) 0.94 (5.) 0.8 (5.9) 45 (97.0) F NA I 7.0 DTHA074S (4) DTHB074S (44) 5.50 (64.8) 4.9 (6.9) 9.7 (49.) 0 (45.0) F WSA E 4.0 DTHA044S DTHB044S 5.50 (64.8) 4.9 (6.9) 9.7 (49.) 40 (54.0) F WSA E 40.0 DTHA0404S DTHB0404S 5.50 (64.8) 4.9 (6.9) 9.7 (49.) 95 (79.0) F WSA E 5.0 DTHA054S DTHB054S 9.90 (75.9) 8.5 (7.5).7 (56.8) 400 (8.0) F WSA E 6.0 DTHA064S DTHB064S 9.90 (75.9) 8.5 (7.5).7 (56.8) 550 (50.0) F WSA E 75.0 DTHA0754S DTHB754S 9.90 (75.9) 8.5 (7.5).7 (56.8) 570 (59.0) F WSA E 9.0 DTHA094S DTHB094S 5.90 (9.).90 (8.0) 6.88 (68.) 685 (.0) F WSA E 8.0 DTHA084S DTHB084S 5.90 (9.).90 (8.0) 6.88 (68.) 765 (47.0) F WSA E 45.0 DTHA0454S DTHB0454S 4.5 (05.5).90 (8.6) 9.88 (75.9) 990 (449.0) F WSA4 E 75.0 DTHB0754S 4.5 (05.5).90 (8.6) 9.88 (75.9) 00 (499.0) F WSA4 E 0.0 DTHB004S 4.5 (05.5).90 (8.6) 9.88 (75.9) 0 (508.0) F WSA4 E 75.0 DTHB00754S (5.8) 9.50 (00.) 5.50 (90.) 090 (948.0) F WSA5 E 0.0 DTHB004S (5.8) 9.50 (00.) 5.50 (90.) 090 (948.0) F WSA5 G DTHB04404S (57.5) (5.6) 4.49 (05.4) 580 (7.7) F WSA7 G DTHB05504S (57.5) (5.6) 4.49 (05.4) 640 (00.0) F WSA7 G DTHB006604S 6.84 (59.6) (7.) 4.49 (05.4) 700 (678.) F WSA6 G Optional wall mounting kits-part # PL799 Optional wall mounting kits-part # PL799 The number in ( ) s following the catalog number is the electrical wiring diagram number. 5
6 Windings, Terminals and Construction kva Winding Winding Insulation System Termination Enclosure Construction Core 7.5 CU wire CU wire 80 C CU wire Epoxy encapsulated Wound/distributed gap -0 AL foil AL foil 80 C CU wire Epoxy encapsulated Wound/distributed gap 7-0 AL foil AL foil 0 C CU bus Ventilated Wound/distributed gap 75-0 AL foil AL foil 0 C AL bus Ventilated Wound/distributed gap AL foil AL foil 0 C AL bus Ventilated Butt stacked/step lap 6
7 WIRING DIAGRAMS 4 PRIMARY: 460 Volts Delta SECONDARY: 460Y/66 Volts TAPS: -5% ANFC and BNFC H H 5 PRIMARY: 460 Volts Delta SECONDARY: 460Y/66 Volts TAPS: - /% ANFC and BNFC H H 7 PRIMARY: 460 Volts Delta SECONDARY: 0Y/ Volts TAPS: -5% ANFC and BNFC H H 8 PRIMARY: 460 Volts Delta SECONDARY: 0Y/ Volts TAPS: - /% ANFC and BNFC H H , X, X 66 & X & X & X X , X, X 66 & X & X & X X , X, X & X & X & X X , X, X & X & X & X X 40 PRIMARY: 575 Volts Delta SECONDARY: 0Y/ Volts TAPS: -5% ANFC and BNFC 4 PRIMARY: 575 Volts Delta SECONDARY: 0Y/ Volts TAPS: - /% ANFC and BNFC 4 PRIMARY: 575 Volts Delta SECONDARY: 460Y/66 Volts TAPS: -5% ANFC and BNFC 44 PRIMARY: 575 Volts Delta SECONDARY: 460Y/66 Volts TAPS: - /% ANFC and BNFC H H H H H H H H , X, X & X & X & X X , X, X X & X & X & X , X, X 66 & X & X & X X , X, X 66 & X & X & X X 59 PRIMARY: 0 Volts Delta SECONDARY: 0Y/ Volts TAPS: - /% ANFC and - /% BNFC 6 PRIMARY: 0 Volts Delta SECONDARY: 0Y/ Volts TAPS: -5% ANFC and -5% BNFC H H H H , X, X & X & X & X X , X, X & X & X & X X DIMENSION DRAWING D D D D H H H H W W W W Design E Design F Design G Design I 7
8 N85 W545 Westbrook Crossing Menomonee Falls, WI hubbell-acmeelectric.com Hubbell Canada Inc Hubbell de Mexico, S.A. de C.V ACM_BRO_00_06
Non-Linear Load Transformers
Non-Linear Load Transformers Acme s Non-Linear Load and Harmonic Mitigating Transformers protect equipment on the line and prevent damage caused by harmonic currents. Many of today s electronic devices
More informationINTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers
INTERNATIONAL TRANSFORMERS Acme Electric s broad selection of CSA energy efficient transformers International Transformers What is CSA C802.2 Compliant? On January 1, 2005, the Canadian Energy Efficiency
More informationGeneral Description & Features Selection Charts Definition of Terms... 42
SECTION NON-LINEAR LOAD ISOLATION TRANSFORMERS Special winding techniques minimize eddy current losses. A double sized neutral handles excessive neutral currents. UL Listed for K Factor Loads 4, 1 & 20.
More informationLoad Isolation Transformers
4 Non-Linear Load Isolation Transformers Section Special winding techniques minimize eddy current losses. A double sized neutral handles excessive neutral currents. UL Listed for K Factor Loads 4, 13 &
More informationGENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS
GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS Acme offers a large selection of Dry-Type Distribution Transformers. Ranging from 600 Volt and below, in both Single and Three Phase, you re sure to find
More informationT S 15KVA 1PH 240/480 Transformer
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T2535173S 15KVA 1PH 240/480 Transformer Acme Electric Catalog Number Manufacturer Description Weight per unit Product
More informationSteps for Selecting the Proper Transformer
SECTION I Page 4 Steps for Selecting the Proper Transformer SINGLE PASE LOADS 1. Determine electrical load A. Voltage required by load. B. Amperes or KVA capacity required by load. C. Frequency in z (cycles
More informationDry Type Transformers Full Line Catalog. jeffersonelectric.com
Dry Type Transformers Full Line Catalog jeffersonelectric.com The Transformer Authority PIONEER TRANSFORMERS: Why us? Scale We produce over 100,000 transformers every year. With this high level of production
More informationPower Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers
Power Quality 13 Answering Today s Power Challenges Jefferson Electric is continually updating its product line to remain on the forefront of transformer technology. Electrical harmonics have become a
More informationFull Line Product Catalog
Full Line Product Catalog TC Table of Contents Dry-Type Distribution Transformers Transformer Questions and Answers 6-13 Enclosure Definition 13 Steps in Transformer Selection 14-17 Construction Features
More informationTransformer Questions & Answers
Transformer Questions & Answers. What is a transformer and how does it work? A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. It can be designed
More informationEnergy Efficient Distribution Transformers
Energy Efficient Distribution Transformers Established in 1917, Hammond Power Solutions Inc. (HPS), is an industry leader in magnetic transformer design and development. With our headquarters in Guelph,
More informationTransformer Questions & Answers
Transformer Questions & Answers. What is a transformer and how does it work? A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. It can be designed
More informationBuck-Boost Transformers
Buck-Boost Transformers Buck Boost transformers are the ideal solution anytime a line voltage change in the 5-15% range is required in single phase or three phase applications. Proper voltage is critical
More informationMGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide
MGM Transformer Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide MGM Transformer Company 5701 Smithway Street Commerce, CA 90040 www.mgmtransformer.com Phone: 323.726.0888
More informationWarehouse Stock Transformers
Warehouse Stock s Warehouse Stock Buck-Boost Application Description and The Buck-Boost has four separate windings, two-windings in the primary and two-windings in the secondary. The unit is designed for
More information500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor
500 kva Dry-type Isolation Transformer - 13200V-Delta to 208Y/120V 3PH - NEMA 1/Indoor Part #: MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Page: 1 The MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Dry-type Isolation
More informationGE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class
GE Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial
More informationand cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.
-156 Purpose & Industrial Control Purpose (1000 kva and Below) mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. shall be manufactured
More informationAmveco Toroidal Solutions. Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications.
Amveco Toroidal Solutions Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications. AMVECO TOROIDAL SOLUTIONS Acme Electric s Amveco brand specializes
More informationDry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION
NON-LINEAR TRANSFORMER PRESENTATION 1 PROBLEM: HARMONICS CAUSE EXCESSIVE TRANSFORMER HEATING Increased Losses Proximity Skin Effect Stray Losses Circulating Effect Triplen Harmonics Add in Neutral Increased
More informationJefferson Electric Inc Product Catalog JE901
Jefferson Electric Inc Product Catalog JE901 Worldwide Products and Services Tradition of Excellence Jefferson Electric has been a pioneer and innovator of magnetic products since 1915. We enjoy a rich
More informationBrown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS
SECTION 16461C - DRY TYPE TRANSFORMERS PART 1 - GENERAL 1.1 This section includes design and performance requirements for dry-type transformers rated for use on secondary distribution systems rated 600
More informationHPS Universal BUCK-BOOST TRANSFORMERS
BUCK-BOOST TRANSFORMERS Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More informationPRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)
PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian) 1.0 General This specification covers the electrical characteristics and
More informationSWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)
SWF DV/DT Solutions Sinewave Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Does your application use variable frequency drives for improved
More informationLIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING
LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING 1.0 General This specification covers the electrical characteristics and general
More informationPower Processor - Series 700F 10KVA to 150KVA
Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines
More information5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R
5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R Part #: MT-ISX-FP-1P-115V-5KVA-230V-N3R Page: 1 The MT-ISX-FP-1P-115V-5KVA-230V-N3R 115V 1 Phase Energy
More information2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.
TECHNICAL SPECIFICATIONS for Single Phase, 1 to 3 KVA Power Conditioner with Regulation and Distribution Constant Power 3 (CP3) CP36508A 7/15/04 1.0 General This specification covers the electrical characteristics
More informationLow Pass Harmonic Filters
Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power
More informationPremium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated
Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated Catalog 7400CT1001 2010 Class 7400 CONTENTS Description.............................................
More informationFull Line Product Catalog
Full Line Product Catalog E L E C T R I C A L TABLE OF CONTENTS SECTION 1 SECTION 2 SECTION 3 Dry-Type Distribution Transformers Transformer Questions & Answers... 6-10 Selection Steps... 11-12 Construction
More informationOpen-Delta Systems Affect Variable Frequency Drives
Open-Delta Systems Affect Variable Frequency Drives To avoid premature drive failure, proper precautions must be taken when installing VFDs on open-delta supplies. Written by: Dan Peters, Yaskawa America,
More information500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R
500 kva Isolation Transformer 480V Delta Primary 400Y/231 Wye Secondary NEMA 3R Part #: MTDOE163P480D500KVA400Y.231N3R Page: 1 The MTDOE163P480D500KVA400Y.231N3R 480 V Delta 3 Phase Energy Efficient Isolation
More informationTech Byte 16: The Truths About Transformers Part 2
In The Truths About Transformers Part 1, the discussion focused on the reality that not all transformers are created equal. Today, more than ever, there is a need to look at every transformer application
More information2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers
.5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings
More informationsave energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers
save energy, it is precious Mfg. of all types of Distribution / Power & Furnace Transformers SYNERGY transformers SAFETY AND EFFICIENCY, COMBINED WITH LONG-TERM RELIABILITY, ARE THE HALLMARKS OF WORLD-RENOWNED
More information225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R
225 kva Autotransformer 240V Delta Primary Voltage 220V Delta Secondary Voltage NEMA 3R Part #: MTATX3P240D225KVA220DN3R Page: 1 The MTATX3P240D225KVA220DN3R 240D 3 Phase Energy Efficient Autotransformer
More informationULTRA-K Series 600K - he
5 kva 500 kva ULTRA-K Series 600K - he High Efficiency K-Rated Power Conditioning Transformers Designed to be used with linear or non-linear loads. Applications: Audio / Video Recording Equipment IT Systems
More informationLow Voltage Transformers. Selection Guide
Low Voltage Transformers Selection Guide Special Purpose Transformers Non-Ventilated Transformers For use in contaminated or dust-laden environments, indoor or outdoor. Export Model Transformers Designed
More informationA Practical Guide to Free Energy Devices
A Practical Guide to Free Energy Devices Part PatD14: Last updated: 25th February 2006 Author: Patrick J. Kelly This patent application shows the details of a device which it is claimed, can produce sufficient
More information2.1. Product Description
.1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions........... Standards and Certifications............... Catalog Selection................
More informationK Factor Power Transformers
Ashley-Edison AsiaElectricTransformers (UK) K Factor Power Transformers DTKF series Low Voltage Dry Type K Factor Power Transformers AET-DTKF-2004-01: Page 1 Asia Electric Transformers, Entrepreneur Business
More informationPANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer
PANELMDP Main Distribution Panel Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Product Type PANELMDP Eaton Corp 1.0 (lbs/each) Three Phase Energy Efficient
More information7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz
7.5 kva Isolation Transformer 460V Primary 230V Secondary NEMA 3R Single Phase 50/60 Hz Part #: MTISX1P460V7.5KVA230VN3R50.60HZ Page: 1 The MTISX1P460V7.5KVA230VN3R50.60HZ 460V 1 Phase Energy Efficient
More informationDry-Type Transformers
Dry-Type Transformers 600 Volt Class Bulletin 7700-99 ISO 9002 Registered 1 Federal Pacific Federal Pacific History During 1987, the Electro-Mechanical Corporation acquired the dry-type transformer division
More information10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R
10 kva Transformer 480V Primary Voltage 208V Secondary Voltage Single Phase NEMA 3R Part #: MTATX1P480V10KVA208VN3R Page: 1 The MTATX1P480V10KVA208VN3R 480V 1 Phase Energy Efficient Encapsulated Transformer
More information80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase
80 kva Isolation Transformer 480V AC Primary 20V AC Secondary NEMA 3R Single Phase Part #: MTDOE161P480V80KVA20VN3R The MTDOE161P480V80KVA20VN3R 480V AC 1 Phase Energy Efficient Isolation Transformer from
More information15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R
15 kva Isolation Transformer Single Phase 208V Primary 120/240V Secondary NEMA 3R Part #: MT20815KVA240.120 Page: 1 The MT20815KVA240.120 208V 1 Phase Energy Efficient Isolation Transformer from Larson
More information2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description
General-Purpose Encapsulated.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Catalog Selection................ Product Selection....................... Single-Phase..........................
More informationWhat is a Transformer?
What is a Transformer? Transformers are completely static electrical devices which convert alternating current from one voltage level to another. General purpose transformers are rated 600 volts and below
More informationVIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs
VIRGINIA TRANSFORMER CORP Individual solutions from a global perspective Drive & Rectifier Transformersrs Oil Drilling Paper Mill Virginia Transformer Commitment to our Customers Industry s Shortest Production
More informationAcme Electric Full Line Product Catalog
Acme Electric N85 W12545 Westbrook Crossing Menomonee Falls, WI 53051 800.334.5214 acmepowerdist.com Acme Electric Full Line Product Catalog Full Line Product Catalog Today, Actuant Electrical provides
More informationStrategies for design 600V large modular UPS for critical power applications
White Paper Markets Served Data centers Strategies for design 600V large modular UPS for critical power applications Executive summary Today s transformerless UPS systems are significantly smaller and
More informationLine Frequency Transformer
Line Frequency Transformer For frequencies of 50/60 Hz, specify a Frequency Transformer. Line Line Frequency Transformers are customized to meet customer requirements, and are available in various ratings.
More informationLiquid-Filled Transformers
Liquid-Filled Transformers Custom Transformers at Standard Prices NIAGARA TRANSFORMER CORP. Induction Furnace Transformer Cycloconverter Rectifier Duty Transformer Arc Furnace Transformer Full Range of
More informationCompliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)
Typical Specification 1.2kV Class Energy Efficient Dry-Type Distribution Transformers Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016) Canada 595 Southgate Drive Guelph, Ontario N1G
More information75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R
75 kva Isolation Transformer 480V Delta Primary 208V Delta Secondary NEMA 3R Part #: MTDOE163P480D75KVA208DN3R Page: 1 The MTDOE163P480D75KVA208DN3R 480D 3 Phase Energy Efficient Isolation Transformer
More informationGeneral Purpose Transformers
Transformers General Purpose Transformers Standard Units 1P 480 x 240V Primary, 120/240V Secondary.25 1D1N205.50 1D1N505.75 1D1N705 1.0 1D1N001 1.5 1D1N105 2.0 1D1N002 3.0 1D1N003 5.0 1D1N005 7.5 1D1N007
More informationHIGH FREQQUENCY TRANSFORMER DESIGN PROGRAM MANUAL V12.0
HITRIN OPTIMIZED PROGRAM SERVICE, LLC Electro-Magnetic Design Using Advanced Computer Techniques HIGH FREQQUENCY TRANSFORMER DESIGN PROGRAM MANUAL V12.0 www.opsprograms.com opseast@opsprograms.com HITRIN
More informationHow adjustable speed drives affect power distribution
How adjustable speed drives affect power distribution Application Note Adjustable speed drives (ASDs) can be both a source and a victim of poor power quality. ASDs as victim loads Although ASDs are usually
More informationYour Presenters. > Thomas Patzner Product Manager, Low Voltage Transformers. > Marquette University Electrical Engineering. > Apprentice Electrician
Your Presenters > Thomas Patzner Product Manager, Low Voltage Transformers > Marquette University Electrical Engineering > Apprentice Electrician > Low Voltage Transformers - Co-op (Square D Company) (lab
More informationCONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI
GENERAL: The scope of this document is to provide instruction for the installation and testing of Medium Voltage, 3 Phase, Pad Mounted Transformers installed at the University of Missouri. Preferred transformers
More informationStandards. n Built in accordance with NEMA, ANSI, UL and CSA standards
Buck-Boost 9 0 VA to 10 Applications n A comprehensive line of transformers for low voltage applications. n Economical for stepping voltages up or down n Solve over/under voltage problems efficiently n
More informationVariable Transformers Product Design & Engineering Data
Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,
More informationUNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1
GENERAL: The scope of this document is to provide instruction for the installation and testing of Medium Voltage, 3 Phase, Pad Mounted Transformers installed at the University of Missouri. Preferred transformers
More informationApplication Note. Applicable Product: AC Drives
Application Note Application Note Guidelines For The Use Of 400-600 Volt AC Drives In Medium Voltage Applications Applicable Product: AC Drives 4kV Step-down Transformer AC Drive 400-600V Output Filter
More informationPower Protection and Conditioning
2/50 Voltage Wave Attenuation CBEMA Constant Voltage Power Supply Voltage surge with a virtual front time of 1.2 ms and a time to half-value of 50 ms delivered across an open circuit. 8/20 Current Wave
More informationPower-Sure 700. Technical Data TD158001EN. Contents
Technical Data TD158001EN Power-Sure 700 Supersedes August 2015 Contents Description Page General description... 2 Power-Sure 700 benefits.... 2 Specifications... 3 Industry standards and certifications...
More informationP2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company
P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Quality Power within your Reach P2 Power Magnetics P2 Power Solutions Pvt. Ltd. P2 Power Solutions Pvt. Ltd. provides EMC and power quality solutions,
More information75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R
75 kva Isolation Transformer 4160V Delta Primary Voltage 480Y/277 Secondary Voltage NEMA 3R Part #: MTISX3P4160D75KVA480Y.277N3R Page: 1 The MTISX3P4160D75KVA480Y.277N3R 4160D 3 Phase Energy Efficient
More informationLarge Kool Mµ Core Shapes
Large Kool Mµ Core Shapes TECHNICAL BULLETIN Ideal for high current inductors, large Kool Mµ geometries (E cores, U Cores and Blocks) offer all the advantages of Kool Mµ material, low core loss, excellent
More informationLVGP. Advanced transformers built for the industrial environment. Catalog: LVGP-16C-English. By Micron Power Delivery. Supersedes: LVGP-16B-English
LVGP By Micron Power Delivery Advanced transformers built for the industrial environment Catalog: LVGP-16C-English Supersedes: LVGP-16B-English Table of Contents Low Voltage General Purpose Transformers
More informationSubject: Drive isolation transformers. VFD definition: History the short version. February 2012
February 2012 Subject: Drive isolation transformers This paper is designed to provide BASIC information on the application of transformers designed to manage secondary loads comprised largely of alternating
More informationDescription & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...
SECTION BUCK-BOOST TRANSFORMERS A simple and economical way to correct offstandard voltages... from 95 to 500 volts; single and three phase, in sizes up to 60 kva. Simplified buck-boost rating charts make
More informationHigh Frequency Sinewave Guardian TM Filter
High Frequency Sinewave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL FORM: SHF-TRM-E REL. April 2015 REV. 001 2015 MTE Corporation Caution Prior to start up; confirm the drive operation mode
More informationFERRORESONANT PROGRAM MANUAL V12.0
FERRO OPTIMIZED PROGRAM SERVICE, LLC Electro-Magnetic Design Using Advanced Computer Techniques FERRORESONANT PROGRAM MANUAL V12.0 www.opsprograms.com opseast@opsprograms.com FERRO PROGRAM DESCRIPTION
More informationBUCK-BOOST TRANSFORMERS
Hammond Power Solutions Inc. Page of Buck-boost transformers represent an economical way to both raise supply voltage caused by line drop or equipment demand on the distribution system; or lower voltage
More informationBridgeport Magnetics Design Guide
Bridgeport Magnetics Design Guide Our design guide takes you step by step through the process of designing a toroidal transformer. No engineering design charges for all standard designs. State of the art
More informationPOWER QUALITY PRODUCTS FOR NON-LINEAR LOADS
Voltage Regulators, Line Voltage Conditioners and Super Isolation Transformers Electrical Problems Related to Power Quality... 138 Electrical Problems on Non-Linear Systems... 139 Protection of Electrical
More informationHigh Frequency SineWave Guardian TM Filter
High Frequency SineWave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference
More informationBALLAST HANDBOOK. Basic Reference Manual. Integral Ballast Characteristics and Performance Data High Pressure Sodium Metal Halide HL-301 5/03
BALLAST Basic Reference Manual Integral Ballast Characteristics and Performance Data High Pressure Sodium Metal Halide HL-301 5/03 BALLAST Why Use Ballasts? The high intensity discharge lamps -high pressure
More informationSINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL
SINGLE PHASE INSTRUCTION MANUAL DIAGRAM D This manual applies to all single-phase buck & boost transformers sold by Larson Electronics. Please refer to the connection diagram on pages 4-6 for properly
More informationIsolation Transformer Series
Isolation Transformer Series Unit Shown With Options ITS Series - Isolation Transformer Series The La Marche Isolation Transformer Series (ITS) is designed for installation in industrial and harsh environment
More informationPOWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS
POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A
More information2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description
General-Purpose Encapsulated Transformers.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Transformers Catalog Selection................ Product Selection....................... Single-Phase..........................
More information2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description
General-Purpose Encapsulated.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Catalog Selection................ Product Selection....................... Single-Phase..........................
More informationDescription. Features and Benefits
KA-108 The General Electric Type KA-108 Bushing Potential Device is a reliable, safe, economical voltage transforming device for the operation of instruments and relays from high-voltage circuits, 115
More information1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R
1.5 kva Single Phase Transformer 120V Primary Voltage 277V Secondary Voltage NEMA 3R Part #: MT120V1.5KVA277V Page: 1 The MT120V1.5KVA277V 120V 1 Phase Energy Efficient Transformer from Larson Electronics
More informationPRODUCT FEATURES TYPICAL APPLICATIONS
The AVR voltage regulator and PLC power conditioner product lines consists of over 250 standard units arranged in 29 different voltage families to provide 95% coverage of day-to-day application needs.
More informationLarge Kool Mµ Core Shapes
Large Kool Mµ Core Shapes Technical Bulletin Ideal for high current inductors, large Kool Mµ geometries (E cores, Toroids, U Cores and Blocks) offer all the advantages of Kool Mµ material, low core loss,
More informationHarmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez
Harmonic Power A VFDs.com Whitepaper Written by Ernesto Jimenez Table of Contents 1. Need for Clean Electricity 2. What Are Harmonics? 3. Lower Order Harmonics 4. Causes of Harmonics 5. Effects of Harmonics
More informationMulti-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7
White Paper Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7 Dr. Jun-koo Kang, Yaskawa Electric America Doc#: WP.AFD.02 Copyright Yaskawa Electric America,
More informationEffective Harmonic Mitigation with Active Filters
Advancing Power Quality White Paper Effective Harmonic Mitigation with Active Filters Written by: Ian Wallace Variable Speed Drive with no Harmonic Mitigation Industry standard variable speed drives, with
More informationAPQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)
APQline Active Harmonic Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Power electronic equipment and AC-DC power conversion equipment contribute
More informationLarge Kool Mµ Core Shapes
Large Kool Mµ Core Shapes TECHNICAL BULLETIN Ideal for high current inductors, large Kool Mµ geometries (E cores, U Cores and Blocks) offer all the advantages of Kool Mµ material, low core loss, excellent
More informationHARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N
HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N Harmonic Basics 3 rd Harmonic Fundamental 5 t1h Harmonic 7 th Harmonic Harmonic
More informationS10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 S10N06P0P KVA 1PH 10/40V 16/3V Buck Boost Transformer Eaton Corp Catalog Manufacturer Description Weight per unit Product
More informationACS 1000 Transformer Failure Investigation. Nathan Schachter, Peng
Investigation Nathan Schachter, Peng Objectives Learn what happened Explain why it happened Discuss solutions Suggest remedies so it does not happen again Prevention is the key to success 2 ACS 1000 VFD
More information