Xu Xiao Ming, AP Services, March 2010 Machine services Life expectance analysis program (LEAP)
|
|
- Magdalen Rice
- 5 years ago
- Views:
Transcription
1 Xu Xiao Ming, AP Services, March 2010 Machine services Life expectance analysis program (LEAP) April 12, 2010 Slide 1 Content MV Machine Winding Insulation Stress LEAP Methodology LEAP Standard LEAP from the Case book LEAP Usage and Uniqueness April 12, 2010 Slide 2 1
2 Basis of analysis Stress & strength v/s time Stress, strength Strength Transient faults Premature Failure Failure Stress (T.E.A.M) Residual Life Time April 12, 2010 Slide 3 Life expectancy analysis Benefits Strength Condition assessment and taking suitable actions at this point. Transient faults Adv. 1: No Premature Failure Stress Residual Life Failure Adv. 2: Increase in Life April 12, 2010 Slide 4 2
3 LEAP not just a step ahead What is LEAP? Lifetime Expectancy Analysis Program or LEAP is a unique Predicative Maintenance Tool for the Stator Winding Insulation of Electric Machines. LEAP provides information on Machine winding and expected residual life, and will optimize the Machine Maintenance Plans LEAP developed by ABB Machines Service, India, is in use for over 12 years, with a database of measurements and analysis in excess of 4000 machines worldwide Measurements are performed by Local or Global ABB Service centers and data analyzed at the LEAP Center of Excellence LEAP is not just a package of inspections; it is a systematic approach to managing Machine Maintenance April 12, 2010 Slide 5 Level based inspections Solution Levels Basic Standard LEAP Levels Packages Data collection (on site or remote): Operational hours, voltage, current, power, slip, Starts/Stops, Temperature (Winding, Coolant and Ambient), Duty cycle & loading pattern, Failure and Maintenance history, Information on power supply, breaker-cable configuration, etc Basic Data Collection Polarization Depolarization Current Analysis PDCA Tan Delta & capacitance Analysis Non-Linear Insulation Behavior Analysis Partial Discharge Analysis Deliverables Life Expectancy Analysis 80% Confidence Level Condition Based Inspection and Maintenance Plan Condition Assessment of Stator Windings for Contamination, ageing, looseness, delamination, stress grading system Life Expectancy Analysis 80% Confidence Level Condition Based Inspection and Maintenance Plan Advanced Premium Standard Data Collection Visual Inspection on end windings Partial Discharge Probe measurements & Dynamic Mechanical Response of Windings Stress analysis of End-windings Advanced Data Collection Wedge Tightness Map & Coupling resistance measurements Visual inspection, including slot areas Stress analysis of Windings Condition Assessment of Stator Windings with Standard Package + End-winding assessment Life Expectancy Analysis 85% Confidence Level Condition Based Inspection and Maintenance Plan Condition Assessment of Stator Windings with Advanced Package + slot region assessment Life Expectancy Analysis 90% Confidence Level Condition Based Inspection and Maintenance Plan April 12, 2010 Slide 6 3
4 Time (sec) Charging Discharging TIME (msecs) U - PHASE V - PHASE W - PHASE UVW - PHASE Voltage (kv) U Phase V Phase W Phase UVW Phase LEAP methodology Collection of Data Operating data, test measurements and machine information is collected using a package of measurements Analysis of Data Data collected is analyzed to identify the process of insulation degradation ABB has developed UNIQUE analytical tools to identify, characterize and quantify defects that could be present within the insulation system Calculation of Stresses Life Expectancy Analysis is performed and factors and conditions that affect lifetime are identified Estimating Life & Condition Based Maintenance Lifetime is estimated with different Confidence levels depending on the LEAP package Clear plans for possible further inspections, maintenance, replacements or even upgrades are drawn up April 12, 2010 Slide 8 LEAP standard package Pol-Depol Currents (microamp) Polarization-Depolarization Currents U PHASE DC Measurements Polarization De-Polarization Current Analysis CAPACITANCE (Arbitrary Units) INSTANTANEOUS CAPACITANCE 5.8 kv TAN DELTA MEASUREMENTS AC Measurements Non Linear Behavior Analysis Tan and Capacitance Analysis Partial Discharge Analysis Tan Delta (%) Remark: DC tests are sensitive to the surface condition, and AC tests give more information on the insulation volume April 12, 2010 Slide 9 4
5 DC measurements Polarization - De-polarization Current Analysis Besides leakage and absorption current, PDCA test gives an idea of quantity and location of charge storage within the machine Identifies contamination even when IR, PI values are acceptable. Determines state of the winding insulation, ageing, looseness, etc. Q3 Q1, Q2 Pol-Depol Currents (microamp) Polarization-Depolarization Currents UVW PHASE Time (sec) Parameters Derived Time constants T1, T2, T3 Charge storage : Q1, Q2, Q3 Ageing Factor Dispersion Ratio (1+Q1+Q2+Q3) Volume Resistivity Charging Discharging April 12, 2010 Slide 10 AC measurements Non Linear Behavior Analysis, Tan and Capacitance Analysis, Partial Discharge Analysis Confirm the results from DC Measurements Assess the condition of Corona protection shield Determine the extent of de-lamination or void content in terms of a percentage of discharging Air Volume to Insulation Volume Assess condition of the Stress Grading system at slot ends Trend Ageing effects INSTANTANEOUS CAPACITANCE 5.8 kv CAPACITANCE (Arbitrary Units) TIME (msecs) U - PHASE V - PHASE W - PHASE UVW - PHASE Remarks: Conventional measurement interpretation is generally based on trends April 12, 2010 Slide 11 5
6 Case study LEAP findings April 12, 2010 Slide 12 Case study LEAP findings April 12, 2010 Slide 13 6
7 Case study LEAP findings April 12, 2010 Slide 14 Case study LEAP Standard 6034 HP, 6 kv, 502A, 1481rpm Purpose of Testing: Routine Outage Inspection RESULTS - PDCA TEST Before Overhauling After Overhauling IR Mohm (> 100) PI (> 2) Q % (7%) Q % (10%) Q % (20%) DR 3.73 (1.25) IR Mohm (> 100) PI 5.63 (> 2) Q % (7%) Q % (10%) Q % (20%) DR 1.25 (1.25) Q3 Key findings: Contamination of windings Recommendation: Cleaning Benefits: Life Extension and improve reliability April 12, 2010 Slide 15 7
8 Case Study Generator - Premium Generator re wound after 18 months Extensive damage recorded on the coil sides in the slots Benefits: Catastrophic Failure Avoided! April 12, 2010 Slide 16 LEAP usage LEAP for Maintenance Planning L1, L2, L3, L4 LEAP for Run/Replace/Retrofit Decisions Measurements and Analysis are to be done at a single occasion (L4) with additional assessment of other components besides the stator windings LEAP for Life Extension/ Upgrade Decisions Measurements and Analysis are to be done at a single occasion (L4) with additional assessment of other components besides the stator windings April 12, 2010 Slide 17 8
9 LEAP How is it different? Methodology is not dependent on old records of measurements performed. Single occasion of measurements will suffice for making decisions. Analysis software is UNIQUE and parameters derived from analysis can be utilized in Life Expectancy Calculations. Can be related to time and integrated into a Maintenance Plan April 12, 2010 Slide 18 April 12, 2010 Slide 19 9
Application of Polarisation Depolarisation Current (PDC) technique on fault and trouble analysis of stator insulation
CIGRE SC A1 & D1 JOINT COLLOQUIUM October 24, 2007 Application of Polarisation Depolarisation Current (PDC) technique on fault and trouble analysis of stator insulation S. A. BHUMIWAT Independent Consultant
More informationBest Practice Reducing The Risk of Arc Flash Cross Over
Best Practice Reducing The Risk of Arc Flash Cross Over 1 2 Electrical Systems Are Critical 3 Why Do We Complete Electrical Maintenance Energized?? 4 Which Bulb Is Not Working?? 5 Functioning Correctly
More informationPARTIAL DISCHARGE MEASUREMENT
PARTIAL DISCHARGE MEASUREMENT Partial Discharges are small electrical sparks which occur predominantly at insulation imperfection. It is the phenomenon which occurs in the insulation on application of
More informationAdvanced Diagnostic Testing Services. Provides detailed and reliable results
Advanced Diagnostic Testing Services Provides detailed and reliable results Advanced Diagnostic Testing Services from the world s leading manufacturer of power transformers ABB leadership begins with our
More informationPARTIAL DISCHARGE MEASUREMENT ON ROTATING MACHINES
PARTIAL DISCHARGE MEASUREMENT ON ROTATING MACHINES Engr. IÑIGO V. ESCOPETE, JR. ITC Level 2 Certified Thermographer PHIL-NCB NDT-UT Level 2 Partial Discharge testing is a Condition Based Maintenance tool
More informationCHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN
75 CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN 5.1 INTRODUCTION Partial Discharge (PD) detection is an important tool for monitoring insulation conditions in high voltage (HV) devices in power systems.
More informationDielectric response and partial discharge measurements on stator insulation at varied low frequency. Nathaniel Taylor
Dielectric response and partial discharge measurements on stator insulation at varied low frequency Nathaniel Taylor Rotating Electrical Machines : The Stator and its Windings turbo-generator motor hydro-generator
More informationIRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors
IRIS POWER TGA-B Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors We have not found another test method that produces as much decision support data for generator
More informationWIRE AND CABLE ENGINEERING GUIDE
Excerpt From Prysmian s WIRE AND CABLE ENGINEERING GUIDE Page 1 of 8 CABLE TESTING Testing represents an integral part in the life of a cable. A cable will be subjected to multiple tests in its lifetime
More informationRESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS
RESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS Authored by: Sanjay Srivastava, Chief Engineer (HE&RM), Rakesh Kumar, Director (HE&RM), R.K. Jayaswal, Dy. Director (HE&RM)
More informationA New Approach for Transformer Bushing Monitoring. Emilio Morales Technical Application Specialist Qualitrol
A New Approach for Transformer Bushing Monitoring Emilio Morales Technical Application Specialist Qualitrol Abstract Transformer bushings are one of the most critical components of a transformer. Up to
More informationGENERATOR TESTING APPLICATION GUIDE. reliable. precision.
GENERATOR TESTING APPLICATION GUIDE www.haefely-hipotronics.com reliable. precision. 2 GENERATOR TESTING CONTENTS Product Line Overview 3 AC Hipot Testing 4 Partial Discharge Measurement 5 DC Hipot Testing
More informationFurther Experience in the Use of Existing RTDs in Windings of Motors and Generators for the Measurement of Partial Discharges
Further Experience in the Use of Existing RDs in Windings of Motors and Generators for the Measurement of Partial Discharges Claude Kane Eaton Electrical Predicative Diagnostics 5421 Feltl Road Suite 190
More informationInsulation resistance testing
Insulation resistance testing Application Note Introduction Insulation resistance testers can be used to determine the integrity of windings or cables in motors, transformers, switchgear, and electrical
More informationKnowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery. Application of EMI Diagnostics to Hydro Generators
Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery Application of EMI Diagnostics to Hydro Generators James Timperley Doble Global Power Services Columbus, Ohio jtimperley@doble.com
More informationTesting of 400 kv GIS
Testing of 400 kv GIS Robert le Roux, Dermot Dorgan, Brian Perry ESB International - Ireland Paper 028 1 Introduction The 400 kv transmission is designed for critical periods of low loading. Due to critical
More informationPartial Discharge Theory, Modeling and Applications To Electrical Machines
Partial Discharge Theory, Modeling and Applications To Electrical Machines V. Vahidinasab, A. Mosallanejad, A. Gholami Department of Electrical Engineering Iran University of Science and Technology (IUST)
More informationAn Overview of Diagnostic Testing of Medium Voltage Power Cables John Densley
An Overview of Diagnostic Testing of Medium Voltage Power Cables John Densley ArborLec Solutions Inc. CIGRE WG 21:04 in 1994 Purpose of diagnostic test is: To evaluate and locate degradation phenomena
More informationSpecialists in HV and MV test and diagnostics. Testing in Substations
Specialists in HV and MV test and diagnostics Testing in Substations Testing in Substations Testing in Substations At 4fores we specialize in the diagnosis and measurement of all types of existing technologies
More informationAfrica Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound
Africa Utility Week Focus Day 2014 Substation Condition Monitoring Benefits of Ultrasound Agenda Review - Substation Condition Monitoring Electrical discharge Types and origin In switchgear Results/consequences
More informationGenerator Users Group Annual Conference Core testing, low and high flux, tap. Mladen Sasic, IRIS Power
Generator Users Group Annual Conference 2015 Core testing, low and high flux, tap Mladen Sasic, IRIS Power Stator Cores Cores provide low reluctance paths for working magnetic fluxes Support stator winding,
More informationPOWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009
POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009 Nkosinathi Buthelezi Senior Consultant: Power Transformers and Reactors Presentation Content Standardization of Power
More informationMV Power Cable Testing Training
MV Power Cable Testing Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq Since power cables are used
More informationDielectric Response Measurements Using DC Voltage
Dielectric Response Measurements Using DC Voltage Jean-François DRAPEAU Researcher Expertise Équipement électriques IREQ ICC Spring 2011 - St Pete Education Session 2011-05-25 OUTLINE Introduction DC charging
More informationRamp Testing in Identifying and Preventing Insulation Failure
FEATURE Megger Ramp Testing in Identifying and Preventing Insulation Failure By Jeff Jowett THE TESTING OF ELECTRICAL INSULATION has Simply taking a spot resistance reading with a megohmmeter seen the
More informationA1-209 EXPERIENCES IN IDENTIFICATION OF PARTIAL DISCHARGE PATTERNS IN LARGE HYDROGENERATORS
21, rue d'artois, F-75008 Paris http://www.cigre.org A1-209 Session 2004 CIGRÉ EXPERIENCES IN IDENTIFICATION OF PARTIAL DISCHARGE PATTERNS IN LARGE HYDROGENERATORS CARLOS AZUAJE* WILLIAM TORRES C.V.G.
More informationIMPORTANCE & PROCESS OF RLA STUDIES IN ASSESSMENT OF NEED FOR R&M - A CASE STUDY. CPRI, Bengaluru
IMPORTANCE & PROCESS OF RLA STUDIES IN ASSESSMENT OF NEED FOR R&M - A CASE STUDY CPRI, Bengaluru What is RLA? RLA is a technique to examine systematically and monitor the plant, during and after service
More informationCONTINUOUS ON-LINE SYSTEM FOR PARTIAL DISCHARGE MONITORING FOR HA1 AT CHE ROBEŞTI
U.P.B. Sci. Bull., Series D, Vol. 77, Iss. 4, 2015 ISSN 1454-2358 CONTINUOUS ON-LINE SYSTEM FOR PARTIAL DISCHARGE MONITORING FOR HA1 AT CHE ROBEŞTI Laurenţiu-Florian ION 1, Apolodor GHEORGHIU 2 A proper
More informationCHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES
23 CHAPTER 2 v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES 2.1 INTRODUCTION For reliable design of power system, proper insulation coordination among the power system equipment is necessary. Insulation
More informationTECHIMP Power Transformer Monitoring
TECHIMP Power Transformer Monitoring Kontakt: Martin Hesse Techimp Germany GmbH i.g. E-Mail: mhesse@techimp.com Tel.: +49 5724 391 007 Mobil: +49 170 2364 735 PD Monitoring of Power Transformers Power
More informationA NOVEL APPROACH TO PARTIAL DISCHARGE MONITORING
A NOVEL APPROACH TO PARTIAL DISCHARGE MONITORING Dr. Simon Higgins Sustainability Division Eskom SOC Ltd (South Africa) Mr. André Tétreault Tests & Diagnostics Division VibroSystM, Inc. (Canada) ABSTRACT
More informationInsulation Co-ordination For HVDC Station
Insulation Co-ordination For HVDC Station Insulation Co-ordination Definitions As per IEC 60071 Insulation Coordination is defined as selection of dielectric strength of equipment in relation to the operating
More informationVariation in SFRA plot due to design and external parameter
Chapter 6 Variation in SFRA plot due to design and external parameter 6.1 Introduction As the experience grows with Sweep Frequency Response Analysis in world, it is useful to discuss the measurements
More informationSERVICE OFFERINGS FOR POWER SYSTEM STUDY & CONDITION MONITORING FOR STATIC EQUIPMENT
SERVICE OFFERINGS FOR POWER SYSTEM STUDY & CONDITION MONITORING FOR STATIC EQUIPMENT Page TABLE OF CONTENTS POWER SYSTEM STUDY: 5 DATA COLLECTION AND NETWORK MODELLING 5 LOAD FLOW STUDY 5 SHORT CIRCUIT
More informationCourse No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION. Course Content
Course No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION Sr. No. Course Content 1.0 Fault Current Calculations 1.1 Introduction to per unit and percentage impedance 1.2
More informationA Study on the Effect of Performing VLF Withstand Tests on Field Aged Degraded Joints
WETS D 15 2.4 Drapeau A Study on the Effect of Performing VLF Withstand Tests on Field Aged Degraded Joints Jean-François DRAPEAU Researcher Expertise Équipement électriques IREQ Jacques CÔTÉ, HQD Simon
More informationA Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment
International Research Journal of Engineering and Technology (IRJET) eissn: 23 0056 Volume: 04 Issue: 02 Feb 2017 www.irjet.net pissn: 072 A Review Comprehension: Guideline for Testing of HV, EHV and UHV
More informationBe on guard for effective testing: Introduction
Be on guard for effective testing: Introduction The development of the insulation tester by Evershed and Vignoles is part of our electrical history, with insulation testers produced by Megger Instruments
More informationDoble Solutions for Partial Discharge. Greg Topjian Solutions Manager
Doble Solutions for Partial Discharge Greg Topjian Solutions Manager 617-393-3129 gtopjian@doble.com Why do we need to conduct PD measurements PD a major cause of early failure for HV insulation. Partial
More informationUSING DAMPED AC VOLTAGES
MODERN & TESTING DIAGNOSIS OF POWER CABLES USING DAMPED AC VOLTAGES BY EDWARD GULSKI AND ROGIER JONGEN, Onsite HV Solutions ag, Switzerland AND RALPH PATTERSON, Power Products & Solutions LLC, United States
More informationCONDITION ASSESSMENT OF ROTATING MACHINES THROUGH OFF- LINE DIAGNOSTIC TESTING
CONDITION ASSESSMENT OF ROTATING MACHINES THROUGH OFF- LINE DIAGNOSTIC TESTING Copyright Material PCIC Europe Paper No. PCIC Middle-East ME18_06 Howard Sedding Christoph Wendel Mladen Sasic Qualitrol Iris
More informationTransformers handling and transport
Special tests (Credit: http://www.breakbulk.com/wp-content/uploads/2015/02/20141117160247x.jpg) Transformers handling and transport Damages that may arise and how to find them Table of contents summary
More informationTesting and PD Diagnosis of MV Cable Systems with DAC Voltage Educational Session May St Pete Beach, Fl
Testing and PD Diagnosis of MV Cable Systems with DAC Voltage Educational Session May 26 2011 St Pete Beach, Fl HDW ELECTRONICS, INC. THE BEST IN CABLE FAULT LOCATING TECHNOLOGY by Henning Oetjen Frank
More informationII. TRADITIONAL APPROACH OF PD MEASUREMENTS
Advantages of Continuous Monitoring of Partial Discharges in Rotating Equipment and Switchgear Claude Kane Cutler Hammer Predictive Diagnostics 5421 Feltl Road, Suite 190 Minnetonka, MN 55343 Phone: 952-912-1358
More informationTECHIMP Technologies & Services for Diagnostics and Monitoring of High Voltage Assets
TECHIMP Technologies & Services for Diagnostics and Monitoring of High Voltage Assets Who we are TECHIMP is one of the leading providers of Condition Assessment Services Data Acquisition and Test Equipment
More informationAnalysis of Partial Discharge Patterns for Generator Stator Windings
American Journal of Electrical Power and Energy Systems 2015; 4(2): 17-22 Published online March 11,2015 (http://www.sciencepublishinggroup.com/j/epes) doi: 10.11648/j.epes.20150402.11 ISSN: 2326-912X
More informationCondition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology
Condition Assessment of High Voltage Insulation in Power System Equipment R.E. James and Q. Su The Institution of Engineering and Technology Contents Preface xi 1 Introduction 1 1.1 Interconnection of
More informationPartial Discharge, Survey or Monitor?
July 2014 Partial Discharge, Survey or Monitor? 24-7 Partial Discharge monitoring is the ultimate tool for finding insulation weaknesses before they fail. Introduction It s well established that Partial
More informationEI HIGH VOLTAGE INSULATION TESTING POLICY
Network(s): Summary: ENGINEERING INSTRUCTION EI 09-0001 HIGH VOLTAGE INSULATION TESTING POLICY EPN, LPN, SPN This engineering instruction details the policy for the on-site insulation testing of new and
More informationTHE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER
THE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER EASY TO USE TESTER THAT FINDS MORE FAULTS. The state of the art Electrom itig II provides a wide range of tests to analyze the condition of insulation
More informationMotoplat CV-014DS TESTER FOR DIAGNOSTICS OF ALTERNATOR STATOR WINDINGS AND DIODE BRIDGES USER MANUAL
2016.09.07 Motoplat CV-014DS TESTER FOR DIAGNOSTICS OF ALTERNATOR STATOR WINDINGS AND DIODE BRIDGES USER MANUAL QUALITY WARRANTY INNOVATION SERVICE TRAINING UNIQUENESS CONTENTS 1. DESCRIPTION... 4 2.
More informationABB Power Products Service
Raben Naidoo, Technology days, May 21-22th, 2014, Cape Town, South Africa, Enhanced availability of transformers via transformer remote monitoring - TEC ABB Power Products Service Why a session on availability?
More informationThe importance of partial discharge testing throughout the development and operation of power transformers
The importance of partial discharge testing throughout the development and operation of power transformers Ulrike Broniecki OMICRON Energy Solutions GmbH, Berlin Power transformers are exposed to intense
More informationMONTRANO. Continuous monitoring system for power transformers
MONTRANO Continuous monitoring system for power transformers Condition monitoring to extend transformer life Knowing the dielectric condition of insulation is vital Dielectric flashover of insulation in
More informationIRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.
IRIS POWER PDTracII Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear. We have not found another test method that produces as much
More informationIntroduction. AC or DC? Insulation Current Flow (AC) 1. TECHNICAL BULLETIN 012a Principles of Insulation Testing. Page 1 of 10 January 9, 2002
Page 1 of 10 January 9, 2002 TECHNICAL BULLETIN 012a Principles of Insulation Testing Introduction Probably 80% of all testing performed in electrical power systems is related to the verification of insulation
More informationChapter 7 Conclusion 7.1 General
Chapter 7 7.1 General The mechanical integrity of a transformer winding is challenged by several mechanisms. Many dielectric failures in transformers are direct results of reduced mechanical strength due
More informationSURFACE CORONA INCEPTION ON STRESS GRADING SYSTEM IN END-TURN REGIONS OF ROTATING MACHINES
SURFACE CORONA INCEPTION ON STRESS GRADING SYSTEM IN END-TURN REGIONS OF ROTATING MACHINES A. Kumada, D. Onishi, T. Nakamura, K. Hidaka, (Univ. of Tokyo) S. A. Boggs (Nonlinear Systems., Inc), Y. Tsuboi,
More informationONLINE OFFLINE B Y WIL L IAM H IG INBOT H AM,
ONLINE OFFLINE VERSUS FEATURE PARTIAL DISCHARGE TESTING FOR CABLE ASSESSMENT B Y WIL L IAM H IG INBOT H AM, EA Technology, LLC Medium voltage cables have three distinct phases to their lifecycle: (1) new
More informationSAMPLE. Determining the health of your power transformer begins with Transformer Clinic s SAMPLE testing programs.
Keep Powering On SAMPLE Determining the health of your power transformer begins with Transformer Clinic s SAMPLE testing programs. Overheating, arcing, partial discharge, and other active or slow-evolving
More informationMaintenance & Diagnosis Strategies. for. High Voltage Substations
Maintenance & Diagnosis Strategies for High Voltage Substations 1/ 52 Robin Fischer, 28 April 2004 Diagnosis of Substation Equipment Power Transformers Instrument Transformers Switch-Gears Breakers Coils
More informationPartial discharge diagnostics on very long and branched cable circuits
11 Nordic Insulation Symposium Stockholm, June 11-13, 2001 Partial discharge diagnostics on very long and branched cable circuits Nico van Schaik, E. Fred Steennis, Wim Boone and Dick M. van Aartrijk KEMA
More informationHVA SERIES VLF TEST SETS. Hipot Testers HVA Series for VLF (0.1 Hz) testing of MV and HV cables.
HVA SERIES VLF TEST SETS Hipot Testers HVA Series for VLF (0.1 Hz) testing of MV and HV cables. INNOVATIVE, RELIABLE, ECONOMICAL HIGH VOLTAGE TESTING FROM b2 HIGH VOLTAGE VLF, DC, cable sheath testing
More informationTHE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER
THE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER AUTOMATED, SAFE, AND EASY TO USE TESTER. HIGH AND LOW VOLTAGE TESTS IN A LIGHTWEIGHT PACKAGE. The state of the art Electrom itig II provides a wide
More informationInvesti ations Into the Use of Temperature Detectors as # tator Winding Partial Discharge Detectors
Conference Record of the 2006 IEEE International Symposium on Electrical Insulation Investi ations Into the Use of Temperature Detectors as # tator Winding Partial Discharge Detectors S.R. Campbell, G.C.
More information5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated
n CAT IV 600 V safety rating n Line supply or battery operated n Noise rejection (3mA or 4mA rms@200v and above) for use in high voltage substations or switchyards n 5mA output current provides fast charging
More informationAdvancements in online partial discharge monitoring and assessment of MV through EHV Substation assets
Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets Abstract: For decades it has been recognized that partial discharge assessment is an excellent method
More informationIRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.
IRIS POWER PDTracII Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear. We have not found another test method that produces as much
More informationONLINE MONITORING OF TURN INSULATION DETERIORATION IN MAINS-FED INDUCTION MACHINES USING ONLINE SURGE TESTING
ONLINE MONITORING OF TURN INSULATION DETERIORATION IN MAINS-FED INDUCTION MACHINES USING ONLINE SURGE TESTING A Thesis Presented to The Academic Faculty by Stefan Grubic In Partial Fulfillment of the Requirements
More informationPORTABLE PARTIAL DISCHARGE MONITORING INSTRUMENT
PORTBLE PRTIL ISCHRGE MONITORING INSTRUMENT Periodic Online Monitoring of Partial ischarges on motors, generators, switchgear, isolated phase bus and dry type transformers. MOTORS TURBO GENERTORS HYRO
More informationCharacteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings
J Electr Eng Technol Vol. 9, No. 1: 280-285, 2014 http://dx.doi.org/10.5370/jeet.2014.9.1.280 ISSN(Print) 1975-0102 ISSN(Online) 2093-7423 Characteristics of Insulation Diagnosis and Failure in Gas Turbine
More informationGenerator Advanced Concepts
Generator Advanced Concepts Common Topics, The Practical Side Machine Output Voltage Equation Pitch Harmonics Circulating Currents when Paralleling Reactances and Time Constants Three Generator Curves
More informationFault Zone Analysis: Six Part Series on Identifying Motor Defects
Fault Zone Analysis: Six Part Series on Identifying Motor Defects Noah P. Bethel PdMA Corporation 5909C Hampton Oaks Parkway Tampa, FL 33610 Ph: 813-621-6463 Fax: 813-620-0206 Web: www.pdma.com E-mail:
More informationTHE EVOLUTION OF NON-INTRUSIVE PARTIAL DISCHARGE TESTING OF MV SWITCHGEAR
THE EVOLUTION OF NON-INTRUSIVE PARTIAL DISCHARGE TESTING OF MV SWITCHGEAR Neil DAVIES and Chris LOWSLEY EA Technology Ltd. - United Kingdom Neil.Davies@eatechnology.com INRODUCTION The trend for extending
More informationThe Basics of Insulation Testing
The Basics of Insulation Testing Feature by Jim Gregorec IDEAL Industries, Inc. What Is Insulation Testing? In a perfect world, all the electrical current sent along a conductive wire would reach its intended
More information10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY
9. INTRODUCTION Control Cabling The protection and control equipment in power plants and substations is influenced by various of environmental conditions. One of the most significant environmental factor
More informationFor Medium Voltage Motors, Generators, Switchgear, Bus Duct and Cable Terminations
InsulGard Product Focus Maximize Your Uptime For Medium Voltage Motors, Generators, Switchgear, Bus uct and Cable erminations InsulGard 1. InsulGard (Front) 2. InsulGard (Back) Why InsulGard?...Economics
More informationApplication of Electrical Signature Analysis. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN
Application of Electrical Signature Analysis Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN Introduction Over the past months we have covered traditional and modern methods of testing electric
More informationWhy partial discharge testing makes good sense
Why partial discharge testing makes good sense PD measurement and analysis have proven to be reliable for detecting defects in the insulation system of electrical assets before major damage or a breakdown
More informationMatz Ohlen Director Transformer Test Systems. Megger Sweden
Matz Ohlen Director Transformer Test Systems Megger Sweden Frequency response analysis of power transformers Measuring and analyzing data as function of frequency, variable frequency diagnostics Impedance
More informationEPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY
EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY EPS AUSTRALIA SERVICES COMPANY OVERVIEW EPS is a recognised company specialising in Electrical, Instrumentation, Structural, Mechanical and
More informationMV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING
Training Title MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING Training Duration 5 days Training Date MV, HV and EHV Switchgear Testing & Commissioning 5 21 25 Sep $3,750 Dubai, UAE In any of the 5 star
More informationPower Factor Insulation Diagnosis: Demystifying Standard Practices
Power Factor Insulation Diagnosis: Demystifying Standard Practices Dinesh Chhajer, PE 4271 Bronze Way, Dallas Tx Phone: (214) 330 3238 Email: dinesh.chhajer@megger.com ABSTRACT Power Factor (PF) testing
More informationGrounding System Theory and Practice
Grounding System Theory and Practice Course No. E-3046 Credit: 3 PDH Grounding System Theory and Practice Velimir Lackovic, Electrical Engineer System grounding has been used since electrical power systems
More informationALL-TEST IV PRO. Very Easy To Use. Economical! MOTOR CIRCUIT ANALYZER PREDICTIVE MAINTENANCE QUALITY CONTROL TROUBLE SHOOTING
Serving the Industry Since 1983 ALL-TEST IV PRO TM MOTOR CIRCUIT ANALYZER PREDICTIVE MAINTENANCE QUALITY CONTROL TROUBLE SHOOTING LOOKING FOR TROUBLE? if so... YOU WILL FIND IT WITH THE ALL-TEST! Revolutionary
More informationOMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates
OMICRON Seminar on Substation Testing and Diagnosis October 23, 2017 Dubai, United Arab Emirates October 24, 2017 Abu Dhabi, United Arab Emirates Time Optimized Substation Asset Testing and Diagnosis Agenda
More informationIMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES
IMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES Thomas Steiner HIGHVOLT Prüftechnik Dresden GmbH Lifecycle of utilities time schedule utilities Tests during life cycle of utilities
More informationADVANCED CIRCUIT BREAKERS OPERATION AND MAINTENANCE SECTOR / ENGINEERING TECHNICAL & CERTIFICATE OF ATTENDANCE TRAINING COURSE
ADVANCED CIRCUIT BREAKERS OPERATION AND MAINTENANCE SECTOR / ENGINEERING TECHNICAL & CERTIFICATE OF ATTENDANCE TRAINING COURSE Circuit Breakers Play An Important Role In The Safe Distribution Of Electrical
More informationPD Diagnostic Applications and TechImp solutions
PD Diagnostic Applications and TechImp solutions Condition Assessment Solutions for Electrical Systems. PD based innovative tools for the Condition Based Maintenance. MD-04.05.004 - rev. 00-29/08/2006
More informationLOW VOLTAGE PWM INVERTER-FED MOTOR INSULATION ISSUES
LOW VOLTAGE PWM INVERTER-FED MOTOR INSULATION ISSUES Copyright Material IEEE Paper No. PCIC-4-15 RAPS-1433 Abstract - The topic of how low voltage IGBT-based PWM inverters create additional insulation
More informationInnovative Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers
Innovative Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers Dr. Michael Krüger, Alexander Kraetge, OMICRON electronics GmbH, Austria Alexander
More informationELEC-E8409 High Voltage Engineering. Condition Monitoring of Power Cables
ELEC-E8409 High Voltage Engineering Condition Monitoring of Power Cables ON-SITE DC MEASUREMENTS Measurements quick and simple, several kv voltage, does not require expensive equipment Insulation Resistance
More informationIMPORTANCE OF INSULATION RESISTANCE
IMPORTANCE OF INSULATION RESISTANCE What is Good Insulation? Every electric wire in your plant whether it s in a motor, generator, cable, switch, transformer, etc., is carefully covered with some form
More informationElectrical Equipment Condition Assessment
Feature Electrical Equipment Condition Assessment Using On-Line Solid Insulation Sampling Importance of Electrical Insulation Electrical insulation plays a vital role in the design and operation of all
More informationInsulation Testing Preventing Equipment Breakdown and Plant Shutdowns
Test&Measurement Insulation Testing Preventing Equipment Breakdown and Plant Shutdowns By Ronit Mukerji, Product Manager General Measuring and Portable Test Instruments, Yokogawa Corporation of America
More informationImpulse Testing as a Predictive Maintenance Tool
Testing as a Predictive Maintenance Tool E. Wiedenbrug SM IEEE, G. Frey M IEEE, J. Wilson, M IEEE Baker Instrument Company engr@bakerinst.com Abstract: testing is an integral part of predictive maintenance
More informationPRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS
PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS n Quality made in Germany n Standardized and customized solutions n Turn key projects, all from one hand 0.1-1/1 Product Portfolio Test and Measuring Systems
More informationTRANSFORMER OPERATIONAL PRINCIPLES, SELECTION & TROUBLESHOOTING
Training Title TRANSFORMER OPERATIONAL PRINCIPLES, SELECTION & TROUBLESHOOTING Training Duration 5 days Training Date Transformer Operational Principles, Selection & Troubleshooting 5 15 19 Nov $4,250
More informationUnderstanding and Extracting Valuable Information from Basic and Advanced Power Transformer Testing Techniques
Understanding and Extracting Valuable Information from Basic and Advanced Power Transformer Testing Techniques Charles Sweetser, Services Manager, PRIM Engineering, Waltham, Mass. Topics of Discussion
More informationFIELD EXPERIENCES USING A PROTOTYPE OPEN CORE RESONATING TRANSFORMER FOR A.C. HIGH POTENTIAL TESTING OF HYDRO-GENERATOR STATORS
Abstract FIELD EXPERIENCES USING A PROTOTYPE OPEN CORE RESONATING TRANSFORMER FOR A.C. HIGH POTENTIAL TESTING OF HYDRO-GENERATOR STATORS Dr. Wade Enright*, Vijay D. Bendre, Simon Bell, Prof. Pat S. Bodger
More information