1 TEST REORT To: Address: T-LINK TECHNOLOGIES CO., LTD. Building 24 (floors1,3,4,5) and 28 (floors1-4) Central Science and Technology ark, Shennan Rd, Nanshan, Shenzhen, China Factory name: T-LINK TECHNOLOGIES CO., LTD. Location: Building 24 (floors1,3,4,5) and 28 (floors1-4) Central Science and Technology ark, Shennan Rd, Nanshan, Shenzhen, China Standards used: AS/NZS : 2011/Amdt 1: 2012 Start date: August 26, 2016 Finish date: September 20, 2016 Sample No: -- Sections examined: All clauses Re-testing: NONE. AC1600 Wireless Gigabit VDSL/ADSL Modem Router Model: Archer VR600 Remark / Note: SEE AGE 2 CONCLUSION: The sample satisfies to the clauses examined Tested by Alan Ao Supervisor / Safety Department Approved by Carter LEE Supervisor / Safety Department Date: September 27, 2016 Date: September 27, 2016 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification age 1 of 54 TEST REORT IEC/EN VER.3

2 History of Remark-Note icture of the problem Modification result: Modification result: Clause icture of the problem Description of the problem: Modification result: age 2 of 54 TEST REORT IEC/EN VER.3

3 Open View age 3 of 54 TEST REORT IEC/EN VER.3

4 age 4 of 54 TEST REORT IEC/EN VER.3

5 Test item description...: Trade Mark...: Manufacturer...: Model/Type reference...: Ratings...: Copy of marking plate: AC1600 Wireless Gigabit VDSL/ADSL Modem Router T-LINK TECHNOLOGIES CO., LTD. Archer VR600 Main unit: 12Vdc, 1.5A; Adapter input: Vac, 50/60Hz, 0.6A; Adapter output: 12Vdc, 1.5A age 5 of 54 TEST REORT IEC/EN VER.3

6 Summary of testing: The equipment under test (EUT) has been evaluated at maximum ambient (Tma) of +40 C according to the manufacturer s declaration. All tests were measured under the worst case, USB load 0.5A, RJ11port and RJ45 ports transmitting data normally. General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. General product information: 1. The equipment is a AC1600 Wireless Gigabit VDSL/ADSL Modem Router r which supplied by external switching power supply, and the external switching power supply output comply with LS. 2. There are TNV-3 circuits and SELV circuits within the EUT. 3. Enclosure was fixed together by screws age 6 of 54 TEST REORT IEC/EN VER.3

7 Test Report No: LD160826N036 Test item particulars... : Equipment mobility...: [X] movable [] hand-held [] transportable [] stationary [] for building-in [] direct plug-in Connection to the mains...: [] pluggable equipment [] type A [] type B [] permanent connection [] detachable power supply cord [] non-detachable power supply cord [X] not directly connected to the mains Operating condition...: [X] continuous [] rated operating / resting time: Access location...: [X] operator accessible [] restricted access location Over voltage category (OVC)...: [] OVC I [] OVC II [] OVC III [] OVC IV [X] other: supplied by external switching power supply Mains supply tolerance (%) or absolute mains supply values...: Tested for IT power systems...: [] Yes IT testing, phase-phase voltage (V)...: [X] No Class of equipment...: [] Class I [] Class II [] Class III [X] Not classified Considered current rating of protective device as part of the building installation (A)...: ollution degree (D)...: [] D 1 [X] D 2 [] D 3 I protection class...: IX0 Altitude during operation (m)...: Below 2000 m Altitude of test laboratory (m)...: Below 2000 m Mass of equipment (kg)...: 0.445kg. ossible test case verdicts: - test case does not apply to the test object... : (Not applicable) - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F (Fail) - test object does not demand..: ND (Not demanded) Testing... : Date of receipt of test item... : August 26, 2016 Date(s) of performance of tests... : August 26, 2016 to September 25, 2016 age 7 of 54 TEST REORT IEC/EN VER.3

8 1 GENERAL 1.5 Components General Components, which were found to affect safety aspects, are conformed to the relevant IEC component standards and/or comply with the requirements of this standard. Comply with IEC or relevant component standard (see appended tables 1.5.1) Evaluation and testing of components Components which are certified to IEC and/or national standards are used correctly within their ratings. Components not covered by IEC standards are tested under the conditions presented in the equipment Thermal controls No thermal controls used Transformers Considered Interconnecting cables Interconnecting cable for Interconnection is carrying only SELV voltages with power consumption below 240 VA Capacitors bridging insulation No such components Resistors bridging insulation No such components Resistors bridging functional, basic or supplementary insulation Resistors bridging double or reinforced insulation between a.c. mains and other circuits Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable No such components. No such components. No such components Components in equipment for IT power systems Surge suppressors No such components General No such components rotection of VDRs No such components Bridging of functional insulation by a VDR No such components. age 8 of 54 TEST REORT IEC/EN VER.3

9 Bridging of basic insulation by a VDR No such components Bridging of supplementary, double or reinforced insulation by a VDR No such components. 1.6 ower interface AC power distribution systems Supplied by approved adapter Input current (see appended table 1.6.2) Voltage limit of hand-held equipment Not such equipment Neutral conductor Not directly connected to the mains 1.7 Marking and instructions ower rating and identification markings See below ower rating marking See below. Multiple mains supply connections...: No such construction. Rated voltage(s) or voltage range(s) (V)... : 12Vdc Symbol for nature of supply, for d.c. only... : DC symbol used Rated frequency or rated frequency range (Hz)... : Rated current (ma or A)... : 1.5A Identification markings See below. Manufacturer s name or trade-mark or identification mark... : Trade-mark: Model identification or type reference... : Archer VR600 Symbol for Class II equipment only... : Other markings and symbols... : Additional symbols or markings do not give risk to misunderstanding Use of graphical symbols Considered Safety instructions and marking See below General Safety related information in English has been evaluated. Manufacturer commits to provide them in the language of the countries where the product will be distributed. age 9 of 54 TEST REORT IEC/EN VER.3

10 Disconnect devices No such device Overcurrent protective device No such device IT power distribution systems Supplied by approved adapter Operator access with a tool No tool is necessary to operate this product Ozone This equipment is not intended to produce the ozone Short duty cycles This equipment is a continuously operation equipment Supply voltage adjustment... : No such device. Methods and means of adjustment; reference to installation instructions... : No such device ower outlets on the equipment... : No power outlets provided Fuse identification (marking, special fusing characteristics, cross-reference)... : No such component Wiring terminals No such terminals rotective earthing and bonding terminals... : Terminals for a.c. mains supply conductors Terminals for d.c. mains supply conductors The equipment is not intended to be connected to the d.c. mains Controls and indicators No safety relevant switch or control Identification, location and marking... : See below Colours... : No safety relevant control or indicator Symbols according to IEC : No safety relevant control or indicator Markings using figures... : No safety relevant switch Isolation of multiple power sources... : Not connected to mains Thermostats and other regulating devices... : No thermostat or other regulating devices Durability The marking was legible after testing, no curiing, not easily be removed. age 10 of 54 TEST REORT IEC/EN VER.3

11 Removable parts No safety marking placed on removable parts Replaceable batteries... : No such component. Language(s)... : Equipment for restricted access locations... : Not intended to be used in restricted access location. 2 ROTECTION FROM HAZARDS 2.1 rotection from electric shock and energy hazards rotection in operator access areas See below Access to energized parts No access with test finger and test pin to any parts with hazards parts. Test by inspection... : See below. Test with test finger (Figure 2A)... : The test finger was unable to contact bare hazardous parts Test with test pin (Figure 2B)... : The test pin was unable to contact bare hazardous parts Test with test probe (Figure 2C)... : The test probe was unable to contact bare TNV parts Battery compartments No such construction Access to ELV wiring No ELV wiring in the equipment. Working voltage (Vpeak or Vrms); minimum distance through insulation (mm) Access to hazardous voltage circuit wiring No hazardous voltage wiring in operator accessible area Energy hazards... : See appended table Manual controls No such device Discharge of capacitors in equipment No such component Measured voltage (V); time-constant (s)... : Energy hazards d.c. mains supply This product is not intended to be connected to d.c. mains supply. a) Capacitor connected to the d.c. mains supply.. : This product is not intended to be connected to d.c. mains supply. age 11 of 54 TEST REORT IEC/EN VER.3

12 b) Internal battery connected to the d.c. mains supply... : This product is not intended to be connected to d.c. mains supply Audio amplifiers... : No such part rotection in service access areas rotection in restricted access locations It is not intended to be used in restricted locations. 2.2 SELV circuits General requirements See below Voltages under normal conditions (V)... : 42.4V peak or 60Vd.c. are not exceeded in SELV circuit under normal operation. Evaluated in adapter report Voltages under fault conditions (V)... : Single fault did not cause excessive voltage in accessible SELV circuit. Limits of 71V peak or 120Vdc were not exceeded and limits of 42.4V peak or 60Vdc were not exceeded for longer than 0.2 seconds. Evaluated in adapter report Connection of SELV circuits to other circuits... : SELV circuit only the connection to SELV circuit. 2.3 TNV circuits Limits No telephone ringing signals are present. Limits are not exceeded under normal condition and fault condition. Type of TNV circuits... : TNV Separation from other circuits and from accessible parts See below General requirements See below rotection by basic insulation Complied rotection by earthing No earthing parts rotection by other constructions... : Separation from hazardous voltages See clause Insulation employed... : age 12 of 54 TEST REORT IEC/EN VER.3

13 2.3.4 Connection of TNV circuits to other circuits TNV circuit is only connect with SELV circuit via basic insulation. Insulation employed... : Basic insulation Test for operating voltages generated externally 2.4 Limited current circuits General requirements No limited current circuit Limit values No limited current circuit Frequency (Hz)... : Measured current (ma)... : Measured voltage (V)... : Measured circuit capacitance (nf or µf)... : Connection of limited current circuits to other circuits No limited current circuit 2.5 Limited power sources a) Inherently limited output No such circuit b) Impedance limited output No such circuit c) Regulating network or IC current limiter, limits output under normal operating and single fault condition See appended table 2.5 Use of integrated circuit (IC) current limiters No such circuit d) Overcurrent protective device limited output No such circuit. Max. output voltage (V), max. output current (A), max. apparent power (VA)... : Current rating of overcurrent protective device (A).: See appended table rovisions for earthing and bonding rotective earthing No protective earthing Functional earthing No protective earthing. Use of symbol for functional earthing...: No protective earthing rotective earthing and protective bonding conductors No protective earthing General No protective earthing Size of protective earthing conductors No protective earthing. age 13 of 54 TEST REORT IEC/EN VER.3

14 Rated current (A), cross-sectional area (mm 2 ), AWG... : Size of protective bonding conductors No protective earthing. Rated current (A), cross-sectional area (mm 2 ), AWG... : rotective current rating (A), cross-sectional area (mm 2 ), AWG... : Resistance of earthing conductors and their terminations; resistance (Ω), voltage drop (V), test current (A), duration (min)... : No protective earthing Colour of insulation... : No protective earthing Terminals No protective earthing General No protective earthing rotective earthing and bonding terminals No protective earthing. Rated current (A), type, nominal thread diameter (mm)... : Separation of the protective earthing conductor from protective bonding conductors No protective earthing Integrity of protective earthing No protective earthing Interconnection of equipment No protective earthing Components in protective earthing conductors and protective bonding conductors No protective earthing Disconnection of protective earth No protective earthing arts that can be removed by an operator No protective earthing arts removed during servicing No protective earthing Corrosion resistance No protective earthing Screws for protective bonding No protective earthing Reliance on telecommunication network or cable distribution system No protective earthing. 2.7 Overcurrent and earth fault protection in primary circuits Basic requirements Supplied by approved adapter. Not connect to a.c. mains directly. Instructions when protection relies on building installation age 14 of 54 TEST REORT IEC/EN VER.3

15 2.7.2 Faults not simulated in Supplied by approved adapter. Not connect to a.c. mains directly Short-circuit backup protection Supplied by approved adapter. Not connect to a.c. mains directly Number and location of protective devices...: Supplied by approved adapter. Not connect to a.c. mains directly rotection by several devices Warning to service personnel...: No service work necessary for the product 2.8 Safety interlocks General principles There is no safety interlock in the equipment rotection requirements There is no safety interlock in the equipment Inadvertent reactivation There is no safety interlock in the equipment Fail-safe operation There is no safety interlock in the equipment. rotection against extreme hazard There is no safety interlock in the equipment Moving parts There is no safety interlock in the equipment Overriding There is no safety interlock in the equipment Switches, relays and their related circuits There is no safety interlock in the equipment Separation distances for contact gaps and their related circuits (mm)... : There is no safety interlock in the equipment Overload test There is no safety interlock in the equipment Endurance test There is no safety interlock in the equipment Electric strength test There is no safety interlock in the equipment Mechanical actuators There is no safety interlock in the equipment. age 15 of 54 TEST REORT IEC/EN VER.3

16 2.9 Electrical insulation roperties of insulating materials Natural rubber, asbestos or hygroscopic materials are not used Humidity conditioning Relative humidity (%), temperature ( C)......: Grade of insulation Only the functional and basic Insulation inside the EUT Separation from hazardous voltages The accessible parts are separated from hazardous parts by reinforced insulation. Method(s) used...: 2.10 Clearances, creepage distances and distances through insulation General See below Frequency... : The frequency does not exceed 30 khz ollution degrees... : This equipment is considered the pollution degree II Reduced values for functional insulation The functional insulation complied with clause c) Intervening unconnected conductive parts Insulation with varying dimensions Not applicable Special separation requirements Insulation in circuits generating starting pulses No such parts Determination of working voltage (See appended table ) General See below RMS working voltage (See appended table ) eak working voltage (See appended table ) Clearances See below General Considered Mains transient voltages Supplied by approved adapter; not directly connected to the a.c. mains. age 16 of 54 TEST REORT IEC/EN VER.3

17 a) AC mains supply... : Supplied by approved adapter; not directly connected to the a.c. mains. b) Earthed d.c. mains supplies... : The equipment is not intended to be supplied by the d.c. mains. c) Unearthed d.c. mains supplies... : The equipment is not intended to be supplied by the d.c. mains. d) Battery operation... : No such battery used Clearances in primary circuits Supplied by approved adapter. Only the functional and basic Insulation inside the EUT Clearances in secondary circuits (See appended table and ) Clearances in circuits having starting pulses No such circuit Transients from a.c. mains supply... : Supplied by approved adapter. Not connect to a.c. mains directly Transients from d.c. mains supply... : The equipment is not intended to be connected to the d.c. mains Transients from telecommunication networks and cable distribution systems... : 1500Vpeak Measurement of transient voltage levels See below. a) Transients from a mains supply Supplied by approved adapter; Not connect to mains directly. For an a.c. mains supply... : Supplied by approved adapter; Not connect to mains directly. For a d.c. mains supply... : Supplied by approved adapter; Not connect to mains directly. b) Transients from a telecommunication network : No used Creepage distances See below General Considered Material group and comparative tracking index Material group IIIb was assumed. age 17 of 54 TEST REORT IEC/EN VER.3

18 CTI tests... : Minimum creepage distances See appended table and Solid insulation See below General No requirement for functional and basic insulation Distances through insulation Insulating compound as solid insulation No such construction Semiconductor devices No such devices Cemented joints No such construction Thin sheet material General Considered Separable thin sheet material Insulation tape used in transformer(t1) Number of layers (pcs)... : Three layers Non-separable thin sheet material No such construction Thin sheet material standard test procedure See clause Electric strength test Thin sheet material alternative test procedure 3 layers of insulation tape were used as basic insulation and any two of three layer complied the testing. Electric strength test See appended table Insulation in wound components No such construction Wire in wound components No such construction. Working voltage... : a) Basic insulation not under stress... : b) Basic, supplementary, reinforced insulation... : c) Compliance with Annex U... : Two wires in contact inside wound component; angle between 45 and : Wire with solvent-based enamel in wound components Electric strength test No such construction. Routine test No such construction Additional insulation in wound components No such construction. age 18 of 54 TEST REORT IEC/EN VER.3

19 Working voltage... : - Basic insulation not under stress... : - Supplementary, reinforced insulation... : Construction of printed boards See below Uncoated printed boards See appended table and Coated printed boards No such printed board used Insulation between conductors on the same inner surface of a printed board Insulation between conductors on different layers of a printed board Distance through insulation Number of insulation layers (pcs)... : No such printed board used Component external terminations No such construction Tests on coated printed boards and coated components No such construction Sample preparation and preliminary inspection Thermal conditioning Electric strength test Abrasion resistance test Thermal cycling No such component Test for ollution Degree 1 environment and insulating compound Tests for semiconductor devices and cemented joints Degree 2 was considered No such device Enclosed and sealed parts No such construction 3 WIRING, CONNECTIONS AND SULY 3.1 General Current rating and overcurrent protection No such consturciton rotection against mechanical damage No such consturciton Securing of internal wiring No such consturciton Insulation of conductors No such consturciton Beads and ceramic insulators No such consturciton Screws for electrical contact pressure No such consturciton. age 19 of 54 TEST REORT IEC/EN VER.3

20 3.1.7 Insulating materials in electrical connections No such consturciton Self-tapping and spaced thread screws No such consturciton Termination of conductors All conductors are reliable secured. 10 N pull test 10N force performed for all relevant conductors. No hazards caused Sleeving on wiring There is no such consturciton 3.2 Connection to a mains supply Means of connection See below Connection to an a.c. mains supply Supplied by approved adater; not directly connect to a.c. mains Connection to a d.c. mains supply Not connected to d.c. mains Multiple supply connections Only one supply connection ermanently connected equipment The equipment is not intended for permanent connection to the mains. Number of conductors, diameter of cable and conduits (mm)...: Appliance inlets No such parts ower supply cords No such parts AC power supply cords No such parts. Type...: Rated current (A), cross-sectional area (mm 2 ), AWG...: DC power supply cords No used Cord anchorages and strain relief No such parts. Mass of equipment (kg), pull (N)...: Longitudinal displacement (mm)...: rotection against mechanical damage Cord guards No such parts. Diameter or minor dimension D (mm); test mass (g)...: Radius of curvature of cord (mm)...: Supply wiring space age 20 of 54 TEST REORT IEC/EN VER.3

21 3.3 Wiring terminals for connection of external conductors Wiring terminals No such terminals Connection of non-detachable power supply cords No such parts Screw terminals No such terminals Conductor sizes to be connected Rated current (A), cord/cable type, cross-sectional area (mm 2 )...: Wiring terminal sizes No such terminals Rated current (A), type, nominal thread diameter (mm)...: Wiring terminal design No such terminals Grouping of wiring terminals Stranded wire 3.4 Disconnection from the mains supply General requirement Supplied by approved adapter, not directly connect to mains Disconnect devices Supplied by approved adapter, not directly connect to mains ermanently connected equipment No permanently connected equipment arts which remain energized Supplied by approved adapter, not directly connect to mains Switches in flexible cords No such construction Number of poles - single-phase and d.c. equipment Supplied by approved adapter, not directly connect to mains Number of poles - three-phase equipment Switches as disconnect devices No such construction lugs as disconnect devices Interconnected equipment Supplied by approved adapter, not directly connect to mains. age 21 of 54 TEST REORT IEC/EN VER.3

22 Multiple power sources Supplied by approved adapter, not directly connect to mains. 3.5 Interconnection of equipment General requirements See below Types of interconnection circuits...: SELV and TNV-3 circuit only ELV circuits as interconnection circuits No ELV interconnection circuits Data ports for additional equipment Complied. 4 HYSICAL REQUIREMENTS 4.1 Stability Angle of 10 For the equipment, the mass is less than 7kg. Test force (N)... : Not floor-standing equipment. 4.2 Mechanical strength General See below. Rack-mounted equipment. age 22 of 54 For the equipment, the mass is less than 7kg Steady force test, 10 N No safety relevant damaged Steady force test, 30 N No door or cover in an operator access area Steady force test, 250 N 250N applied to outer enclosure. No energy or other hazards Impact test After test, no safety relevant damages. Fall test Swing test After test, no safety relevant damages. After test, no safety relevant damages Drop test; height (mm)... : Stress relief test After test, no safety relevant damages Cathode ray tubes No CRT in the EUT. icture tube separately certified... : No CRT in the EUT. TEST REORT IEC/EN VER.3

23 4.2.9 High pressure lamps No high pressure lamps Wall or ceiling mounted equipment; force (N)... : After test with a force 50N, no safety relevant damages. 4.3 Design and construction Edges and corners Edges and corners of the enclosure are rounded Handles and manual controls; force (N)...: No such device Adjustable controls No such device Securing of parts Electrical and mechanical connections and parts withstand usual mechanical stress Connection by plugs and sockets No mismatch of connectors, plugs or sockets possible Direct plug-in equipment Supplied by approved adater. Torque... : Compliance with the relevant mains plug standard... : No such part Heating elements in earthed equipment No such device Batteries No batteries used - Overcharging of a rechargeable battery No batteries used - Unintentional charging of a non-rechargeable battery No batteries used - Reverse charging of a rechargeable battery No batteries used - Excessive discharging rate for any battery No batteries used Oil and grease No oil and grease inside the equipment Dust, powders, liquids and gases The equipment is not intended to be exposed to dust, powers, liquids and gases Containers for liquids or gases No container for liquids or gases provided Flammable liquids... : No flammable liquids in the equipment. Quantity of liquid (l)... : No flammable liquids in the equipment. age 23 of 54 TEST REORT IEC/EN VER.3

24 Flash point ( C)... : No flammable liquids in the equipment Radiation See below General Only LED indicator used Ionizing radiation No ionizing radiation. Measured radiation (pa/kg)... : Measured high-voltage (kv)... : Measured focus voltage (kv)... : CRT markings... : Effect of ultraviolet (UV) radiation on materials No UV radiation. art, property, retention after test, flammability classification... : No UV radiation Human exposure to ultraviolet (UV) radiation... : No UV radiation Lasers (including laser diodes) and LEDs Only LED indicator used Lasers (including laser diodes) No such devices. Laser class... : Light emitting diodes (LEDs) Only LED indicator used Other types... : No such devices. 4.4 rotection against hazardous moving parts General No hazardous moving part used rotection in operator access areas... : No hazardous moving part used. Household and home/office document/media shredders age 24 of 54 No hazardous moving part used rotection in restricted access locations... : No hazardous moving part used rotection in service access areas No hazardous moving part used rotection against moving fan blades No hazardous moving part used General No hazardous moving part used.. Not considered to cause pain or injury. a).: Is considered to cause pain, not injury. b) : Considered to cause injury. c) : TEST REORT IEC/EN VER.3

25 rotection for users No hazardous moving part used. Use of symbol or warning : No hazardous moving part used rotection for service persons No hazardous moving part used. Use of symbol or warning : 4.5 Thermal requirements General See below Temperature tests (see appended table 4.5) Normal load condition per Annex L... : Maximum normal operation Temperature limits for materials (see appended table 4.5) Touch temperature limits (see appended table 4.5) Resistance to abnormal heat... : The phenolic materials used for bobbin of transformer (T1) which is accepted without the further testing. 4.6 Openings in enclosures Top and side openings No hazard voltage and energy hazard inside enclosure. Bottom openings designed to compliy with clause only. See Dimensions (mm)... : age 25 of 54 Numerous circle openings with diameter 3.2mm max Bottoms of fire enclosures No fire enclosure used. Construction of the bottomm, dimensions (mm).. : Doors or covers in fire enclosures No such construction Openings in transportable equipment Not transportable equipment Constructional design measures Not transportable equipment. Dimensions (mm)... : Evaluation measures for larger openings Not transportable equipment Use of metallized parts Not transportable equipment Adhesives for constructional purposes No such construction Conditioning temperature ( C), time (weeks)... : TEST REORT IEC/EN VER.3

26 4.7 Resistance to fire Reducing the risk of ignition and spread of flame See below. Method 1, selection and application of components wiring and materials Method 2, application of all of simulated fault condition tests Selection of components for the simulation of faults with acceptable results. Method 1 used Conditions for a fire enclosure See below arts requiring a fire enclosure No need the fire enclosure arts not requiring a fire enclosure Exteranal power supply output comply with the LS, and all components are equipped on V-1 min. CB in EUT Materials General See appended table Materials for fire enclosures No such parts Materials for components and other parts outside fire enclosures Materials for components and other parts inside fire enclosures No such parts No such parts Materials for air filter assemblies No such devices Materials used in high-voltage components No such devices 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 5.1 Touch current and protective conductor current General Supplied by approved adapter Configuration of equipment under test (EUT) Supplied by approved adapter Single connection to an a.c. mains supply Supplied by approved adapter Redundant multiple connections to an a.c. mains supply Simultaneous multiple connections to an a.c. mains supply Supplied by approved adapter. Supplied by approved adapter Test circuit Supplied by approved adapter. age 26 of 54 TEST REORT IEC/EN VER.3

27 5.1.4 Application of measuring instrument Supplied by approved adapter Test procedure Supplied by approved adapter Test measurements Supplied by approved adapter. Supply voltage (V)... : Measured touch current (ma)... : Max. allowed touch current (ma)... : Measured protective conductor current (ma)... : Max. allowed protective conductor current (ma)... : Equipment with touch current exceeding 3,5 ma Supplied by approved adapter General... : Supplied by approved adapter Simultaneous multiple connections to the supply No such construction Touch currents to telecommunication networks and cable distribution systems and from telecommunication networks Limitation of the touch current to a telecommunication network or to a cable distribution system Supply voltage (V)... : Supplied by approved adapter. Supplied by approved adapter. Measured touch current (ma)... : 0.01mA Max. allowed touch current (ma)... : 0.25mA Summation of touch currents from telecommunication networks a) EUT with earthed telecommunication ports... : b) EUT whose telecommunication ports have no reference to protective earth 5.2 Electric strength General See appended table Test procedure See appended table Abnormal operating and fault conditions rotection against overload and abnormal operation age 27 of 54 See below. TEST REORT IEC/EN VER.3

28 5.3.2 Motors No motor used Transformers See appended table Functional insulation... : Considered c) Electromechanical components No electromechanical component Audio amplifiers in ITE... : No such parts Simulation of faults (see appended table 5.3) Unattended equipment The equipment was not for unattended use Compliance criteria for abnormal operating and fault conditions No flame in the equipment. No molten metal was emitted During the tests No flame in the equipment. No molten metal was emitted After the tests No reduction of clearance and creepage distance. Electric strength test were passed 6 CONNECTION TO TELECOMMUNICATION NETWORKS 6.1 rotection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment rotection from hazardous voltages Separation of the telecommunication network from earth Requirements Supply voltage (V)... : Current in the test circuit (ma)... : Exclusions... : 6.2 rotection of equipment users from overvoltages on telecommunication networks Separation requirements Considered Electric strength test procedure See below Impulse test See appended table Steady-state test See appended table Compliance criteria No breakdown of insulation. age 28 of 54 TEST REORT IEC/EN VER.3

29 6.3 rotection of the telecommunication wiring system from overheating Max. output current (A)... : Current limiting method... : 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS 7.1 General No connection to the cable distribution system. 7.2 rotection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment 7.3 rotection of equipment users from overvoltages on the cable distribution system 7.4 Insulation between primary circuits and cable distribution systems No connection to the cable distribution system. No connection to the cable distribution system. No connection to the cable distribution system General No connection to the cable distribution system Voltage surge test No connection to the cable distribution system Impulse test No connection to the cable distribution system. A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see ) The mass of the EUT is less than 18 kg. A.1.1 Samples... : Wall thickness (mm)... : A.1.2 Conditioning of samples; temperature ( C)... : A.1.3 Mounting of samples... : A.1.4 Test flame (see IEC ) Flame A, B, C or D... : A.1.5 Test procedure A.1.6 Compliance criteria Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... : age 29 of 54 TEST REORT IEC/EN VER.3

30 A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see and ) A.2.1 Samples, material... : Wall thickness (mm)... : A.2.2 Conditioning of samples; temperature ( C) : A.2.3 Mounting of samples... : A.2.4 Test flame (see IEC ) Flame A, B or C... : A.2.5 Test procedure A.2.6 Compliance criteria Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... : A.2.7 Alternative test acc. to IEC , cl. 5 and 9 Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... : A.3 Hot flaming oil test (see 4.6.2) A.3.1 Mounting of samples A.3.2 Test procedure A.3.3 Compliance criterion B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see and 5.3.2) B.1 General requirements No motor used. osition... : Manufacturer... : Type... : Rated values... : B.2 Test conditions No motor used. B.3 Maximum temperatures No motor used. B.4 Running overload test No motor used. B.5 Locked-rotor overload test No motor used. Test duration (days)... : age 30 of 54 TEST REORT IEC/EN VER.3

31 Electric strength test: test voltage (V)... : B.6 Running overload test for d.c. motors in secondary circuits No motor used. B.6.1 General No motor used. B.6.2 Test procedure No motor used. B.6.3 Alternative test procedure No motor used. B.6.4 Electric strength test; test voltage (V)... : No motor used. B.7 Locked-rotor overload test for d.c. motors in secondary circuits No motor used. B.7.1 General No motor used. B.7.2 Test procedure No motor used. B.7.3 Alternative test procedure No motor used. B.7.4 Electric strength test; test voltage (V)... : No motor used. B.8 Test for motors with capacitors No motor used. B.9 Test for three-phase motors No motor used. B.10 Test for series motors No motor used. Operating voltage (V)... : C ANNEX C, TRANSFORMERS (see and 5.3.3) osition... : Manufacturer... : Type... : Rated values... : Method of protection...: C.1 Overload test Supplied by approved adapter. C.2 Insulation Supplied by approved adapter. rotection from displacement of windings...: Supplied by approved adapter. D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see 5.1.4) D.1 Measuring instrument Supplied by approved adapter. D.2 Alternative measuring instrument age 31 of 54 TEST REORT IEC/EN VER.3

32 E ANNEX E, TEMERATURE RISE OF A WINDING (see ) F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEAGE DISTANCES (see 2.10 and Annex G) G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES G.1 Clearances Not used. G.1.1 General Not used. G.1.2 Summary of the procedure for determining minimum clearances Not used. G.2 Determination of mains transient voltage (V) Not used. G.2.1 AC mains supply... : G.2.2 Earthed d.c. mains supplies... : G.2.3 Unearthed d.c. mains supplies... : G.2.4 Battery operation... : G.3 Determination of telecommunication network transient voltage (V)...: Not used. G.4 Determination of required withstand voltage (V) Not used. G.4.1 Mains transients and internal repetitive peaks... : G.4.2 Transients from telecommunication networks... : G.4.3 Combination of transients G.4.4 Transients from cable distribution systems G.5 Measurement of transient voltages (V) Not used. a) Transients from a mains supply For an a.c. mains supply For a d.c. mains supply b) Transients from a telecommunication network G.6 Determination of minimum clearances...: Not used. H ANNEX H, IONIZING RADIATION (see ) J ANNEX J, TABLE OF ELECTROCHEMICAL OTENTIALS (see ) Metal(s) used... : age 32 of 54 TEST REORT IEC/EN VER.3

33 K ANNEX K, THERMAL CONTROLS (see and 5.3.8) K.1 Making and breaking capacity No thermal control in the EUT. K.2 Thermostat reliability; operating voltage (V)... : No thermal control in the EUT. K.3 Thermostat endurance test; operating voltage (V)... : K.4 Temperature limiter endurance; operating voltage (V)... : No thermal control in the EUT. No thermal control in the EUT. K.5 Thermal cut-out reliability No thermal control in the EUT. K.6 Stability of operation No thermal control in the EUT. L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYES OF ELECTRICAL BUSINESS EQUIMENT (see and 4.5.2) L.1 Typewriters No such device in the EUT. L.2 Adding machines and cash registers No such device in the EUT. L.3 Erasers No such device in the EUT. L.4 encil sharpeners No such device in the EUT. L.5 Duplicators and copy machines No such device in the EUT. L.6 Motor-operated files No such device in the EUT. L.7 Other business equipment Considered. M ANNEX M, CRITERIA FOR TELEHONE RINGING SIGNALS (see 2.3.1) M.1 Introduction No phone ringing was generated in the EUT. M.2 Method A No phone ringing was generated in the EUT. M.3 Method B No phone ringing was generated in the EUT. M.3.1 Ringing signal No phone ringing was generated in the EUT. M Frequency (Hz)... : M Voltage (V)... : M Cadence; time (s), voltage (V)... : M Single fault current (ma)... : M.3.2 Tripping device and monitoring voltage... : No phone ringing was generated in the EUT. age 33 of 54 TEST REORT IEC/EN VER.3

34 M Conditions for use of a tripping device or a monitoring voltage No phone ringing was generated in the EUT. M Tripping device No phone ringing was generated in the EUT. M Monitoring voltage (V)... : No phone ringing was generated in the EUT. N ANNEX N, IMULSE TEST GENERATORS (see , , , , 7.3.2, and Clause G.5) N.1 ITU-T impulse test generators Not used. N.2 IEC impulse test generator Not used. ANNEX, NORMATIVE REFERENCES Q ANNEX Q, Voltage dependent resistors (VDRs) (see ) - referred climatic categories... : No such device - Maximum continuous voltage... : No such device - Combination pulse current... : No such device Body of the VDR Test according to IEC : Body of the VDR. Flammability class of material ( min V-1)...: No such device No such device R ANNEX R, EXAMLES OF REQUIREMENTS FOR QUALITY CONTROL ROGRAMMES R.1 Minimum separation distances for unpopulated coated printed boards (see ) R.2 Reduced clearances (see ) S ANNEX S, ROCEDURE FOR IMULSE TESTING (see ) S.1 Test equipment S.2 Test procedure S.3 Examples of waveforms during impulse testing T ANNEX T, GUIDANCE ON ROTECTION AGAINST INGRESS OF WATER (see 1.1.2) age 34 of 54 TEST REORT IEC/EN VER.3

35 U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see ) V ANNEX V, AC OWER DISTRIBUTION SYSTEMS (see 1.6.1) V.1 Introduction Supplied by approved adapter. V.2 TN power distribution systems Supplied by approved adapter. W ANNEX W, SUMMATION OF TOUCH CURRENTS W.1 Touch current from electronic circuits Supplied by approved adapter. W.1.1 Floating circuits W.1.2 Earthed circuits W.2 Interconnection of several equipments W.2.1 Isolation W.2.2 Common return, isolated from earth W.2.3 Common return, connected to protective earth X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause C.1) X.1 Determination of maximum input current X.2 Overload test procedure Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see ) Y.1 Test apparatus... : Not used. Y.2 Mounting of test samples... : Not used. Y.3 Carbon-arc light-exposure apparatus... : Not used. Y.4 Xenon-arc light exposure apparatus... : Not used. Z ANNEX Z, OVERVOLTAGE CATEGORIES (see and Clause G.2) AA ANNEX AA, MANDREL TEST (see ) age 35 of 54 TEST REORT IEC/EN VER.3

36 BB ANNEX BB, CHANGES IN THE SECOND EDITION CC ANNEX CC, Evaluation of integrated circuit (IC) current limiters CC.1 General CC.2 Test program 1.: CC.3 Test program 2.: CC.4 Test program 3...: CC.5 Compliance...: DD ANNEX DD, Requirements for the mounting means of rack-mounted equipment DD.1 General No such construction. DD.2 Mechanical strength test, variable N..: No such construction. DD.3 DD.4 Mechanical strength test, 250N, including end stops : Compliance. : No such construction. No such construction. EE ANNEX EE, Household and home/office document/media shredders EE.1 General No such device. EE.2 Markings and instructions No such device. Use of markings or symbols : No such device. Information of user instructions, maintenance and/or servicing instructions : No such device. EE.3 Inadvertent reactivation test : No such device. EE.4 Disconnection of power to hazardous moving parts: No such device. Use of markings or symbols : No such device. EE.5 rotection against hazardous moving parts No such device. Test with test finger (Figure 2A) : No such device. Test with wedge probe (Figure EE1 and EE2) : No such device. age 36 of 54 TEST REORT IEC/EN VER.3

37 National differences Australia and New Zealand IEC , 2nd edition ZZ1 INTRODUCTION This Appendix sets out variations and additional requirements to cover issues which have not been addressed by the International Standard. These variations indicate national variations for purposes of the IECEE CB System and will be published in the IECEE CB Bulletin. ZZ2 VARIATIONS The following variations apply to the source text. 1.2 Insert the following between person, service and range, rated frequency : OTENTIAL IGNITION SOURCE Insert a new Clause after Clause as follows: OTENTIAL IGNITION SOURCE ossible fault which can start a fire if the opencircuit voltage measured across an interruption or faulty contact exceeds a value of 50 V (peak) a.c. or d.c. and the product of the peak value of this voltage and the measured r.m.s. current under normal operating conditions exceeds 15 VA. Such a faulty contact or interruption in an electrical connection includes those which may occur in CONDUCTIVE ATTERNS on RINTED BOARDS. NOTE 201 An electronic protection circuit may be used to prevent such a fault from becoming a OTENTIAL IGNITION SOURCE. NOTE 202 This definition is from AS/NZS 60065: Add the following to the end of the first paragraph: or the relevant Australian/New Zealand Standard. 2. In NOTE 1, add the following after the word standard : or an Australian/New Zealand Standard Add the following to the end of the first and third dash items: or the relevant Australian/New Zealand Standard Insert Insert Added. Added. age 37 of 54 TEST REORT IEC/EN VER.3

38 Modify Table 3B as follows: 1. Delete the first four rows and replace with the following: RATED CURRENT of equipment A Over 0.2 up to and including 3 Over 3 up to and including 7.5 Over 7.5 up to and including 10 Over 10 up to and including Delete NOTE 1. Minimum conductor sizes Nominal crosssectional area mm 2 AWG or kcmil [crosssectional area in mm 2 ] see note 2 0,5 a 18 [0,8] 0,75 16 [1,3] (0,75) b 1,00 16 [1,3] (1,0 ) c 1,5 14 [2] 3. Delete Footnote a and replace with the following: a This nominal cross-sectional area is only allowed for Class II appliances if the length of the power supply cord, measured between the point where the cord, or cord guard, enters the appliance, and the entry to the plug does not exceed 2 m (0,5 mm 2 three-core supply flexible cords are not permitted; see AS/NZS 3191) Insert a new Clause after Clause 4.1 as follows: Display devices used for television purposes Display devices which may be used for television purposes, with a mass of 7 kg or more, shall comply with the requirements for stability and mechanical hazards, including the additional stability requirements for television receivers, specified in AS/NZS No such display used for television age 38 of 54 TEST REORT IEC/EN VER.3

TEST REPORT. Building 24 (floors1,3,4,5) and 28 (floors1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Standards used:

TEST REPORT. Building 24 (floors1,3,4,5) and 28 (floors1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Standards used: TEST REPORT To: Address: TP-LINK TECHNOLOGIES CO., LTD. Building 24 (floors1,3,4,5) and 28 (floors1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Factory name: TP-LINK TECHNOLOGIES

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3 1 Report No.: BL-SZ1680316-102 Revision History Version Issue Date Revision Content Rev. 01 Oct. 25, 2016 Initial Issue Rev. 02 Rev. 03 Rev. 04 Mar. 08, 2017 Mar. 17, 2017 Mar. 23, 2017 Evaluation of TNV

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number... : ES150530373S Date of issue... : June 26, 2015 Total number of pages.: 79 CB Testing Laboratory...

More information

TEST REPORT. To: Legrand Limoges To: - Attn: OLIVIER CHABROUX Attn: - Address: 128 Av du Marechal De Lattre

TEST REPORT. To: Legrand Limoges To: - Attn: OLIVIER CHABROUX Attn: - Address: 128 Av du Marechal De Lattre TEST REORT To: Legrand Limoges To: - Attn: OLIVIER CHABROUX Attn: - Address: 128 Av du Marechal De Lattre Address: - De Tassigny 87045 LIMOGES Cedex France Fax: -- Fax: - E-mail: -- E-mail: - This document

More information

TEST REPORT IEC :2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC :2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT :2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Number.... : 16C2012S Date

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number... : ES150318170S-1 Date of issue... : April 16, 2015 Total number of pages.: 75 CB Testing Laboratory...

More information

TEST REPORT EN Information technology equipment Safety Part 1: General requirements

TEST REPORT EN Information technology equipment Safety Part 1: General requirements age 1 of 56 TEST REORT EN 60950-1 Information technology equipment Safety art 1: General requirements Report Reference No... : Tested by (name + signature)...: Compiled by (name+ signature)...: Approved

More information

Page 3 of 49 Report Ref. No.:

Page 3 of 49 Report Ref. No.: age 3 of 49 Report Ref. No.: 211-300485-000 Copy of marking plate The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements

More information

LOW VOLTAGE DIRECTIVE TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN : 2006+A11:2009+A1:2010+A12:2011+A2:2013

LOW VOLTAGE DIRECTIVE TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN : 2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 50 Report No.: L482629L329 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Report Reference No....

More information

SAFETY TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN :2006+A11:2009+A1:2010+A12:2011+A2:2013

SAFETY TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN :2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 50 Report No.: L813120L132 SAFETY TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Report Reference No.... : L813120L132

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : T221-0052/16 Date of issue... : 2016-07-14

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Report Reference No.... : age 1 of 100 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements 160918071GZU-001 Date of

More information

CHINA WORLD CONNECTION(HK) CO.,LTD CHINA WORLD CONNECTION(HK) CO.,LTD

CHINA WORLD CONNECTION(HK) CO.,LTD CHINA WORLD CONNECTION(HK) CO.,LTD CHINA WORLD CONNECTION(HK) CO.,LTD LVD REORT repared For : CHINA WORLD CONNECTION(HK) CO.,LTD Room 608, Ban Tian Group Business Center Building, Lipu Street,West Changfa Road, Bantian, Longgang District.,Shenzhen

More information

TEST REPORT. Reference No.:A Report No.:LVDA Page:2 of 34 Date:Feb. 20, 2003

TEST REPORT. Reference No.:A Report No.:LVDA Page:2 of 34 Date:Feb. 20, 2003 age:2 of 34 Type of test object... : Wireless 11b Card Bus Trademark... : MSI Model and/or type reference... : MS-6802 Manufacturer... : MICRO-STAR IT L CO., LTD. Rating(s)... : DC 3.3V, 400 ma articulars:

More information

SAFETY TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN : 2006+A11:2009+A1:2010+A12:2011+A2:2013

SAFETY TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN : 2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 50 Report No.: L642913L282 SAFETY TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Report Reference No.... : L642913L282

More information

CERTIFICATE CERTIFY THAT:

CERTIFICATE CERTIFY THAT: SPORTON LAB. Certificate No: L442480L129 CERTIFICATE EQUIPMENT: Embedded Bluetooth AT Module MODEL NO. : TRBLU24-00100, TRBLU24-00100-NA, BISMS02BI, BISMS02BI-NA APPLICANT: Laird Technologies 11160 Thompson

More information

:2006+A11:2009+A1:2010+A12:2011+A2:2013

:2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 54 Report No.:L612818L022 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Information technology

More information

SABLE-X AND SABLE-X-R2 DEVELOPMENT BOARD SAFETY CHECKLIST TEST REPORT

SABLE-X AND SABLE-X-R2 DEVELOPMENT BOARD SAFETY CHECKLIST TEST REPORT SABLE-X AND SABLE-X-R2 DEVELOPMENT BOARD SAFETY CHECKLIST TEST REPORT EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 + A2:2013 Last updated May 22, 2017 330-0172-R3.0 Copyright 2015-2017 LSR Page 1 of 68

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : 1772059S.50 Date of issue... : 2017-07-20 Total number

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Report Number....: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements SHES130700266901 Date of issue...: 2013-09-04

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2012-12-21 Page 1 of 68 Report Reference # NC8736-A1-IT-5 Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part 1: General requirements NC8736-A1-IT-5

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of www.nemko.com TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : 312253 Date of issue... : 2016-07-11

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2012-12-11 Page 1 of 52 Report Reference # E211395-A3-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT Information technology equipment - Safety - Part

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No....

More information

Page 2 of 69 VDE Report No.: / DC - DC Converter for building in. TDK Innoveta Inc. iba - Series (see model matrix appendix 1)

Page 2 of 69 VDE Report No.: / DC - DC Converter for building in. TDK Innoveta Inc. iba - Series (see model matrix appendix 1) Page 2 of 69 VDE Report No.: 2520400-3336-0009/132550 Test item description... : Trade Mark...: Manufacturer...: Model/Type reference...: Serial Number..: Ratings...: Input: Output: Ambient: DC - DC Converter

More information

Standard ECMA-287 Technical Report EACEM TR-027

Standard ECMA-287 Technical Report EACEM TR-027 EACEM Safety of electronic equipment Standard ECMA-287 Technical Report EACEM TR-027 ECMA Standardizing Information and Communication Systems Phone: +41 22 849.60.00 - Fax: +41 22 849.60.01 - www.ecma.ch

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number.... : 1510061STO-001 Date of issue... : 29 October 2015 Total

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number.... : LCS1612152124S Date of issue... : 2016-12-23 Total number of pages... : 37 Applicant s name... : Address...

More information

TEST REPORT. EN Information technology equipment Safety Part 1: General requirements EMC-CE-S1082. Jae-Kyu, Lee. EMC Compliance Ltd.

TEST REPORT. EN Information technology equipment Safety Part 1: General requirements EMC-CE-S1082. Jae-Kyu, Lee. EMC Compliance Ltd. TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : Tested by (printed name and signature)... : Approved by (printed name and signature)... : EMC-CE-S1082

More information

TEST REPORT EN Information technology equipment Safety Part 1: General requirements

TEST REPORT EN Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT EN 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : SA1703052L 01001 Date of issue... : 2017-03-21

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Page 1 of 69 Test Report issued under the responsibility: TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number....: 140314044GZU-009 Date of issue...: Jan. 9,

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB 1 Science ark Drive, 118221 Singapore TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... :

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2013-01-16 Page 1 of 51 Report Reference # E238623-A131-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2013-01-08 Page 1 of 52 Report Reference # E238623-A89-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

HAND-HELD MULTIMETERS

HAND-HELD MULTIMETERS Test Report issued under the responsibility of: TEST REORT IEC 61010-1, and IEC 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use. art 1: General requirements,

More information

page 2 of 86 Report reference No:

page 2 of 86 Report reference No: articulars: test item vs. test requirements 3. Classification 3.1. Utilization category: (A or B)... : A 3.2. Interruption medium: (air, vacuum, gas Break)... : Air 3.3. Design: (open construction, moulded

More information

EC Declaration of Conformity

EC Declaration of Conformity EC Declaration of Conformity EC Declaration of Conformity According to Low Voltage Directive 2006/95/EC Report No: Type of equipment: Model Name: Applicant: Address: Manufacturer: Address: Test Standards:

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT Information technology equipment Safety Part 1: General requirements Report

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : OFF-4787534005-A-1 Date of issue... : 2016-08-29

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2013-01-08 Page 1 of 51 Report Reference # E238623-A110-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD. (INDIA) VT. LTD. Clause Requirement Test Results Remarks Verdict 5 Marking and documentation 5.1 Marking 5.1.1 General Markings shall be visible from the exterior, or be visible after removing a cover

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT Information technology equipment Safety art 1: General requirements Report Number....

More information

ATTESTATION OF CONFORMITY

ATTESTATION OF CONFORMITY ATTESTATION OF CONFORMITY According to Low Voltage Directive 2006/95/EC No. Product KBW-2014-SI-010 NETWORK CAMERA Model /Trade ref. SNZ-6320 Holder of Certificate Manufacturer Trade Mark SAMSUNG TECHWIN

More information

Report Number....: Test Report issued under the responsibility of Page 1 of 104 TEST REPORT IEC Information technology equipment Safety Part 1

Report Number....: Test Report issued under the responsibility of Page 1 of 104 TEST REPORT IEC Information technology equipment Safety Part 1 Report Number....: Test Report issued under the responsibility of age 1 of 104 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements HK12010466-1 Date of issue...:

More information

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS SAUDI STANDARD NO. SASO IEC 60669-2-2: 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS Part 2-2: Particular requirements Electromagnetic remote-control switches (RCS) SAUDI ARABIAN

More information

TEST REPORT DIN V VDE V :2006 Automatic disconnecting device

TEST REPORT DIN V VDE V :2006 Automatic disconnecting device age 1 of 23 TEST REORT Automatic disconnecting device Report Reference No...: GZ10080033-1 Date of issue...: August 18, 2010 Total number of pages... 23 pages Testing Laboratory...: Address...: Tested

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of SHENZHEN MUST POWER LIMITED. Inverter. Model(s): EP301012E-1000W, EP301512E-1500W, EP302012E-2000W

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of SHENZHEN MUST POWER LIMITED. Inverter. Model(s): EP301012E-1000W, EP301512E-1500W, EP302012E-2000W SHEZHE EMTEK CO., LTD. REORT O.: ES101214112S ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of SHEZHE MUST OWER LIMITED Inverter Model(s): E301012E-1000W, E301512E-1500W, E302012E-2000W repared For : SHEZHE

More information

TEST REPORT IEC , IEC

TEST REPORT IEC , IEC Test Report issued under the responsibility of: TEST REORT IEC 61010-1, IEC 61010-2-032 and IEC 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use. art

More information

TEST REPORT IEC Adjustable speed electrical power drive systems Part 5-1: Safety requirements Electrical, thermal and energy

TEST REPORT IEC Adjustable speed electrical power drive systems Part 5-1: Safety requirements Electrical, thermal and energy Test Report issued under the responsibility of: TEST REPORT Adjustable speed electrical power drive systems Part 5-1: Safety requirements Electrical, thermal and energy Report Reference No.... : 4787846262

More information

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 32 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements Section Thirteen d.c. or a.c. supplied electronic

More information

CB Testing Laboratory...:EZÚ Address...:Pod Lisem Praha71-Trója Testing location/ procedure...: CBTL RMT SMT WMT TMP IEC60947_2C

CB Testing Laboratory...:EZÚ Address...:Pod Lisem Praha71-Trója Testing location/ procedure...: CBTL RMT SMT WMT TMP IEC60947_2C age 1 of 109 Report No.600332-04/01 TEST REORT Low-voltage switchgear and controlgear art 2: Circuit - breakers Report Reference No....: 600332-04/01 Tested by (name+signature)...:... Witnessed by (name+signature)...:...

More information

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements Test Report issued under the responsibility of: TEST REORT IEC 60065 Audio, video and similar electronic apparatus - Safety requirements Report Number.... : 17706907 001 Date of issue... : See cover page

More information

TEST REPORT EN Safety of information technology equipment Part 1-General requirements

TEST REPORT EN Safety of information technology equipment Part 1-General requirements TEST REORT E 60950-1 Safety of information technology equipment art 1-General requirements Report reference o...: R2XM180207051-03 Compiled by (+ signature)...: Test Engineer: Acan Liang Approved by (+

More information

Prüfbericht / Test Report Nr. / No (Edition 2)

Prüfbericht / Test Report Nr. / No (Edition 2) May 31, 2012 age 1 of 74 rüfbericht / Test Report Nr. / No. 11383-04388-2 (Edition 2) Auftraggeber Applicant Geräteart Type of equipment Typenbezeichnung Type designation Auftragsnummer / Order No. rüfgrundlage

More information

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60065 Audio, video and similar electronic apparatus - Safety requirements Report Number... : 246847 Date of issue... : October

More information

HI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date

HI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date Last Amended on - Page 1 of 14 I. AUDIO EQUIPMENT 1. Audio-Video and Similar Electronics Apparatus Safety Requirement Marking & Instructions Laser Radiation (Products Marked Class I only) Heating under

More information

Test Report THREE PHASE FULLY AUTOMATIC AC VOLTAGE REGULATOR

Test Report THREE PHASE FULLY AUTOMATIC AC VOLTAGE REGULATOR Test Report Applicant: GUANGDONG EAST OWER CO., LTD roduct: THREE HASE FULLY AUTOMATIC AC VOLTAGE REGULATOR Brand Name: EAST Model No: ZTY-30KVA repared by: Most Technology Service Co., Limited The safety

More information

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 31 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements Section Thirteen d.c. or a.c. supplied electronic

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

Test Report. The safety testing has been performed on the submitted samples and found in compliance with the council LVD directive 2006/95/EC.

Test Report. The safety testing has been performed on the submitted samples and found in compliance with the council LVD directive 2006/95/EC. Test Report Applicant: GUANGDONG EAST OWER CO., LTD roduct: FULLY AUTOMATIC AC VOLTAGE REGULATOR Brand Name: EAST Model No: ZTY-20KVA, ZTY-10KVA, ZTY-15KVA repared by: Most Technology Service Co., Limited

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207721-AS3-1 CB/DE1-55140 Date of issue...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: 285573 Date of issue...: 2015-09-15

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 210282-CI3-2 CB DE1-56459 Date of issue...

More information

Shenzhen BST Technology Co., Ltd. Report No.: BST Y-1SR-2 XIAMEN RGBLINK SCIENCE & TECHNOLOGY CO., LTD. TEST REPORT

Shenzhen BST Technology Co., Ltd. Report No.: BST Y-1SR-2 XIAMEN RGBLINK SCIENCE & TECHNOLOGY CO., LTD. TEST REPORT Report o.: BST1703503790002-1Y-1SR-2 XIAME RGBLIK SCIECE & TECHOLOGY CO., LTD. TEST REORT repared For: XIAME RGBLIK SCIECE & TECHOLOGY CO., LTD. S603-604 Weiye building Torch Hi-Tech Industrial Development

More information

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 38 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements Section Thirteen d.c. or a.c. supplied electronic

More information

DE Total. American Inc. IEC Test Report Form. If this. and appended to General disclaimer: the NCB, VDE File. No VDE File.

DE Total. American Inc. IEC Test Report Form. If this. and appended to General disclaimer: the NCB, VDE File. No VDE File. 1Fdar Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: 215009-CI3-1 Date of issue...: 2015-07-31

More information

TEST REPORT EN Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements

TEST REPORT EN Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements age 1 of 81 TEST REORT EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General requirements Report Number.... : S12WR-009 Date of issue... :

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference

More information

EC Declaration of Conformity

EC Declaration of Conformity EC Declaration of Conformity EC Declaration of Conformity According to Low Voltage Directive 2006/95/EC Report No: Type of equipment: Model Name: Applicant: Address: Manufacturer: Address: EMC-CE-S1244

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2007-10-24 Page 1 of 6 Report Reference # E210157-A29-UL-1 SPECIFIC TECHNICAL CRITERIA UL 60950-1, First Edition Information technology equipment - Safety- Part 1: General Requirements Report

More information

Report no GZU-001. Growatt 30000TL3-S, Growatt 30000TL3-SE. Max. input current: 34A/34A 38A/38A

Report no GZU-001. Growatt 30000TL3-S, Growatt 30000TL3-SE. Max. input current: 34A/34A 38A/38A age 2 of 27 Rating : Model Max. DC input Voltage: 30000TL3-S, 30000TL3-SE 33000TL3-S, 33000TL3-SE Input 1000Vdc 40000TL3- NS, 40000TL3- NSE 50000TL3-S, 50000TL3-SE Max. input current: 34A/34A 38A/38A DC

More information

Shenzhen BST Technology Co., Ltd. Report No.: BST SR ITUNER NETWORKS CORPORATION

Shenzhen BST Technology Co., Ltd. Report No.: BST SR ITUNER NETWORKS CORPORATION Report o.: BST180610402210SR ITUER ETWORKS CORPORATIO LVD REPORT Prepared For: ITUER ETWORKS CORPORATIO 47801 Fremont Blvd. Fremont, CA. 94538 Product ame: OPEUPS Trade ame: OPEUPS Model: OPEUPS Prepared

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 212475-CI3-1 CBDE1-52299/A1/M1 Date of issue...

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-01-12 Page 1 of 1 Report Reference # E203413-A46-CB-4 COVER PAGE FOR TEST REPORT Test Item Description: Personal Computer Model/Type Reference: MS-6289, MS-6410xxxxxx, Hetis 945xxxxxx,

More information

Prepared by Mick Maytum

Prepared by Mick Maytum IEC Technical Committee 109: Standards on insulation co-ordination for low-voltage equipment Warning Prepared by Mick Maytum mjmaytum@gmail.com The document content is of a general nature only and is not

More information

TEST REPORT IEC Low-voltage switchgear and controlgear - Part 2: Circuit-breakers

TEST REPORT IEC Low-voltage switchgear and controlgear - Part 2: Circuit-breakers Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and controlgear - art 2: Circuit-breakers Report Reference No.... : 3305316.50 Date of issue... : 2013-09-17 Total number

More information

ITC ENGINEERING SERVICES, INC.

ITC ENGINEERING SERVICES, INC. Test Report issued under the responsibility of: ITC ENGINEERING SERVICES, INC. IEC 61010-1:2010, Safety Requirements for Electrical Equipment For Measurement, Control and Laboratory Use art 1 General Requirements

More information

Page 4 of 8 Report No. 11029568 003 Summary of testing: Tests performed (name of test and test clause): All applicable tests as described in Test Case and Measurement Sections were performed. Tests performed

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 34 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements Section Thirteen d.c. or a.c. supplied electronic

More information

IEC , 2 Ed. ( ) TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING

IEC , 2 Ed. ( ) TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING IEC YTEM FOR CONFIRMITY TETING AND COMMITTEE OF TETING LABORATORIE IEC 62368-1, 2 Ed. (2014-02) TETING AND MEAURING EQUIPMENT/ALLOWED UBCONTRACTING R = Required to be at Lab IEC 62368-1 test equipment

More information

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2

More information

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product

More information

Current Transducer CTSR 1-P = 1A

Current Transducer CTSR 1-P = 1A Current Transducer CTSR 1-P I PRN = 1A For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary (high power) and the secondary circuit (electronic circuit).

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer ITL 4000-S I PN = 4000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I > 0 P Features Closed

More information

TEST REPORT IEC Contactors and motor-starters Electromechanical contactors and motor-starters

TEST REPORT IEC Contactors and motor-starters Electromechanical contactors and motor-starters Test Report issued under the responsibility of: TEST REORT Contactors and motor-starters Electromechanical contactors and motor-starters Report Number.... : SH11090656-001 Date of issue... : October 19,

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Current Transducer CTSR 0.6-TP/SP2 I PRN = 600 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Features

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS CONTENTS CONTENTS CONTENTS 1. SAFETY INFORMATION...1 1.1 Preliminary...1 1.2 Dos and don ts...2 1.3 Symbols...3 1.4 Precautions...4 2. DESCRIPTION...5 2.1 Names of parts...6 2.2 Switches, buttons and input

More information

TEST REPORT EN Safety of information technology equipment Part 1-General requirements

TEST REPORT EN Safety of information technology equipment Part 1-General requirements TEST REORT E 60950-1 Safety of information technology equipment art 1-General requirements Report reference o... : R2XM180306052-A1-03 Compiled by (+ signature)... : Test Engineer: Acan Liang Approved

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

EN Information technology equipment Safety Part 1: General requirements

EN Information technology equipment Safety Part 1: General requirements EN 61010-1 Information technology equipment Safety Part 1: General requirements Report Number....: 14PP083-01_1 Date of issue...: 2013-09-05 Total number of pages... 25 Tested by...: Thomas Rogg (printed

More information

TEST REPORT IEC Safety of household and similar electrical appliances

TEST REPORT IEC Safety of household and similar electrical appliances 0 Test Report issued under the responsibility of: TEST REORT Safety of household and similar electrical appliances Report Number.... : T211-0704/13 Date of issue... : 2013-12-20 Total number of pages...

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-05-31 Page 1 of 27 Report Reference # E122103-A38-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 270292 Main Report No.... : 261294

More information

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM

More information