TEST REPORT EN Safety of information technology equipment Part 1-General requirements

Size: px
Start display at page:

Download "TEST REPORT EN Safety of information technology equipment Part 1-General requirements"

Transcription

1 TEST REORT E Safety of information technology equipment art 1-General requirements Report reference o...: R2XM Compiled by (+ signature)...: Test Engineer: Acan Liang Approved by (+ signature)...: Team Leader: Robin He Date of issue...: Testing laboratory...: Bay Area Compliance Laboratories Corp. (Dongguan) Address...: o.69, ulongcun, uxinhu Industry Area, Tangxia, Dongguan, Guangdong, China Testing location...: As above Applicant s name...: United GULF GATE Co. Address...: Aladel Tower, F21, Fahad Al Salem St., State of KUWAIT Manufacturer s name...: Same as applicant Address...: Same as applicant Factory s name...: /A Address...: /A Standard...: E :2006+A11:2009+A1:2010+A12:2011+A2:2013 Test sample(s) received...: Test in period...: to rocedure deviation...: /A on-standard test method...: /A ote: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the specific product described herein. It must not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). age 1 of 67

2 Report o.: R2XM Test item description...: I BX Trademark...: Model/type reference...: XT-120 I-BX Manufacturer...: Same as applicant Rating...: EUT input: V~, 50/60Hz, 0.5A Max. Copy of marking plate: The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective CBs that own these marks. ote: - The CE marking and WEEE symbol (if any) should be at least 5.0mm and 7.0mm respectively in height. - Manufacturers shall ensure that the equipment bears a type, batch or serial number or other element allowing its identification. - Manufacturers shall indicate on the electrical equipment their name, registered trade name or registered trade mark and the postal address at which they can be contacted. - Importers shall indicate on the electrical equipment their name, registered trade name or registered trade mark and the postal address at which they can be contacted. age 2 of 67

3 Test item particulars... : Report o.: R2XM Equipment mobility...: movable hand-held transportable stationary for building-in direct plug-in Connection to the mains...: pluggable equipment type A type B detachable power supply cord non-detachable power supply cord permanent connection not directly connected to the mains Operating condition... : continuous rated operating / resting time: Access location... : operator accessible restricted access location Over voltage category (OVC)... : OVC I OVC II OVC III OVC IV other Mains supply tolerance (%)... : +10%, -10% (requested by applicant) Tested for IT power systems... : Yes o IT testing, phase-phase voltage (V)... : 230V (only for orway) Class of equipment... : Class I Class II Class III Considered current rating of protective device as part of the building installlation (A)... : 16A ot classified ollution degree (D)... : D 1 D 2 D 3 I protection class... : IX0 Altitude during operation (m)... : Up to 2000m Altitude of test laboratory (m)... : Below 2000m Max. Specified ambient temperature( C)... : 40 C Mass of equipment (kg)... : 2.75kg ossible test case verdicts... : - test case does not apply to the test object... : /A(or ) - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F(ail) General remarks: (see remark #) refers to a remark appended to the report. (see appended table) refers to a table appended to the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the testing laboratory. Throughout this report a comma/ point is used as the decimal separator. age 3 of 67

4 Report o.: R2XM Summary of testing: All tests were performed on the worst case and all test results complied with the standard on the cover page. General product information: 1. The product named I BX is designed as information technology equipment, for indoor use only. 2. The product is a class I equipment, supplied by a V AC mains. 3. The equipment is a rack fixed and horizontal installation equipment, specific installation method see the instructions. 4. Before placing the products in the different countries, the manufacturer must ensure that: Operating Instructions, Ratings Labels and Warnings Labels are in an Accepted or Official Language of the country in question; The equipment complies with the ational Standards and/or Electrical Codes of the country, province or city or in question. age 4 of 67

5 E Report o.: R2XM GEERAL 1.5 Components General Comply with IEC or relevant component standard Components that were found to affect safety aspects comply with the requirements of this standard or within the safety aspects of the relevant IEC component standards. (see appended table 1.5.1) Evaluation and testing of components Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this Standard. Components not certified are used in accordance with their ratings and they comply with IEC and the relevant component Standard. Components, for which no relevant IEC Standard exist, have been tested under the condition occurring in the equipment, using applicable parts of IEC Thermal controls o such component Transformers Interconnecting cables Comply with the relevant requirements of this standard Capacitors bridging insulation Resistors bridging insulation Resistors bridging functional, basic or supplementary insulation Resistors bridging double or reinforced insulation between a.c. mains and other circuits Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable Components in equipment for IT power systems Only for orway Surge suppressors General age 5 of 67

6 E Report o.: R2XM rotection of VDRs By fuse FS1 for switching power supply Bridging of functional insulation by a VDR Bridging of basic insulation by a VDR Bridging of supplementary, double or reinforced insulation by a VDR 1.6 ower interface AC power distribution systems T and IT(Only for orway) Input current (see appended table 1.6.2) Voltage limit of hand-held equipment ot hand-held equipment eutral conductor 1.7 Marking and instructions ower rating and identification markings ower rating marking See below Multiple mains supply connections...: Rated voltage(s) or voltage range(s) (V)... : Symbol for nature of supply, for d.c. only... : Rated frequency or rated frequency range (Hz)... : 50/60 Rated current (ma or A)... : 0.5A Identification markings Manufacturer s name or trade-mark or identification mark... : See the label Model identification or type reference... : See the label Symbol for Class II equipment only... : Class I equipment Other markings and symbols... : Others marking can be added, which not misunderstand Use of graphical symbols Considered Safety instructions and marking In user manual General Disconnect devices Appliance inlet is intended to serve as the disconnect device -for permanently connected equipment, a readily accessible disconnect device shall be incorporated in the building installation wiring ot permanently connected equipment age 6 of 67

7 E Report o.: R2XM for pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible Appliance inlet used as disconneted device Overcurrent protective device luggable equipment Type A IT power distribution systems The following or similar information was given in the user manual. The product is designed for IT power distribution system Operator access with a tool Ozone The equipment does not produce ozone Short duty cycles Continuous operation Supply voltage adjustment... : o voltage selector Methods and means of adjustment; reference to installation instructions... : ower outlets on the equipment... : o standard power outlet Fuse identification (marking, special fusing characteristics, cross-reference)... : Wiring terminals rotective earthing and bonding terminals... : Terminals for a.c. mains supply conductors The equipment not for permanent connection or not provided with a nondetachable power supply cord Terminals for d.c. mains supply conductors o connection to d.c. mains supply Controls and indicators See below Identification, location and marking... : The correct marking are used adjacent to the switch Colours... : Safety is not involved Symbols according to IEC : I and indicate the O, and O indicate the "OFF" Markings using figures... : Isolation of multiple power sources... : Thermostats and other regulating devices... : Durability Rubbed with a cloth soaked with water for 15s then again for 15s with cloth soaked with petroleum spirit, after this test, the marking on the label did not fade there are no curling nor lifting of the label edge. age 7 of 67

8 E Report o.: R2XM Removable parts o such removable parts Replaceable batteries... : See below Language(s)... : CAUTIO RISK OF EXLOSIO IF BATTERY IS RELACED BY A ICORRECT TYE. DISOSE OF USED BATTERIES ACCORDIG TO THE ISTRUCTIOS Equipment for restricted access locations... : 2 ROTECTIO FROM HAZARDS 2.1 rotection from electric shock and energy hazards rotection in operator access areas See below Access to energized parts Test by inspection... : Test with test finger (Figure 2A)... : Test with test pin (Figure 2B)... : Test with test probe (Figure 2C)... : o hazardous live parts can be accessed o hazardous live parts can be accessed o hazardous live parts can be accessed TV circuits can not be accessed Battery compartments o such component Access to ELV wiring o ELV wring Working voltage (Vpeak or Vrms); minimum distance through insulation (mm) Access to hazardous voltage circuit wiring Energy hazards... : (see appended table ) Manual controls Discharge of capacitors in equipment Measured voltage (V); time-constant (s)... : Been evaluated in approved switching power supply Energy hazards - d.c. mains supply o connection to d.c. mains supply a) Capacitor connected to the d.c. mains supply. : b) Internal battery connected to the d.c. mains supply... : Audio amplifiers... : o audio amplifiers age 8 of 67

9 E Report o.: R2XM rotection in service access areas o bare parts operating at HAZARDOUS VOLTAGES in a service access area rotection in restricted access locations Equipment not intended for installation in restricted access locations 2.2 SELV circuits General requirements See below Voltages under normal conditions (V)... : 42.4V peak or 60V d.c. are not exceeded in SELV circuits Voltages under fault conditions (V)... : ot exceed 42.4V peak or 60V d.c. for longer than 0.2s, and under limit of 71V peak or 120V d.c. within 0.2s Connection of SELV circuits to other circuits... : Only connection to SELV circuit 2.3 TV circuits Limits - When telephone ringing signals are present: see Annex M; - When telephone ringing signals are not present: ort 5 TI5 to RIG5: a. The max. U under normal operating conditions: 48Vdc; b. The max. U across 5K ohm resistor in the event of a single fault: R5 short circuit: 20Vdc; C1 short circuit: 48Vdc; U2 pin (4-5) short circuit: 20Vdc; All value measured on fault condition not exceed 120Vdc. Type of TV circuits... : TV-3 circuits Separation from other circuits and from accessible parts See below General requirements Complied rotection by basic insulation rotection by earthing rotection by other constructions... : After test, no hazards Separation from hazardous voltages See clause age 9 of 67

10 E Report o.: R2XM Insulation employed... : Connection of TV circuits to other circuits TV circuit is separated from primary circuit by double insulation or reinforced insulation Insulation employed... : Double insulation or reinforced insulation Test for operating voltages generated externally 2.4 Limited current circuits General requirements Limit values LCC be evaluated in approved switching power supplies, see appended table Frequency (Hz)... : Measured current (Ma)... : Measured voltage (V)... : Measured circuit capacitance (nf or µf)... : Connection of limited current circuits to other circuits LCC be evaluated in approved switching power supplies, see appended table Limited power sources a) Inherently limited output b) Impedance limited output c) Regulating network or IC current limiter, limits output under normal operating and single fault condition Use of integrated circuit (IC) current limiters (See appended table 2.5) d) Overcurrent protective device limited output Max. Output voltage (V), max. Output current (A), max. Apparent power (VA)... : Current rating of overcurrent protective device (A).: (See appended table 2.5) 2.6 rovisions for earthing and bonding rotective earthing Reliable earthing terminal Functional earthing o functional earthing. Use of symbol for functional earthing...: age 10 of 67

11 E Report o.: R2XM rotective earthing and protective bonding conductors General Size of protective earthing conductors Rated current (A), cross-sectional area (mm 2 ), AWG... : Assessment by test Size of protective bonding conductors Rated current (A), cross-sectional area (mm 2 ), AWG... : Assessment by test rotective current rating (A), cross-sectional area (mm 2 ), AWG... : Resistance of earthing conductors and their terminations; resistance (Ω), voltage drop (V), test current (A), duration (min)... : age 11 of 67 Assessment by test The earth terminal of AC inlet to the farthest metal enclosure: Resistance: 0.01Ω; Voltage drop: 0.32V; Test current: 32A; Duration: 2min Colour of insulation... : Green-and-Yellow wire used Terminals See below General The earthing terminal in approved AC inlet is used as protective earthing terminal. And a separate protective earthing terminal permanently connected to earth rotective earthing and bonding terminals Reliable earthing terminal Rated current (A), type, nominal thread diameter (mm)... : Separation of the protective earthing conductor from protective bonding conductors 1.5A, Screw type, 2.9mm The earthing terminal in approved AC inlet is used as protective earthing terminal Integrity of protective earthing See below Interconnection of equipment Components in protective earthing conductors and protective bonding conductors Disconnection of protective earth rotective earthing connections be disconnected after the relevant hazard is removed at the same time arts that can be removed by an operator arts removed during servicing Corrosion resistance Complied Screws for protective bonding Complied.

12 E Report o.: R2XM Reliance on telecommunication network or cable distribution system ot reliance on telecommunication network or cable distribution system 2.7 Overcurrent and earth fault protection in primary circuits Basic requirements rotection in primary circuits against over currents provided as an integral part of the equipment. Instructions when protection relies on building installation Faults not simulated in Considered Short-circuit backup protection luggable equipment type A umber and location of protective devices... : Case A, Fuse link FS1 is provided which protects against overcurrent rotection by several devices Warning to service personnel... : 2.8 Safety interlocks General principles o safety interlocks rotection requirements Inadvertent reactivation Fail-safe operation rotection against extreme hazard Moving parts Overriding Switches, relays and their related circuits Separation distances for contact gaps and their related circuits (mm)... : Overload test Endurance test Electric strength test Mechanical actuators 2.9 Electrical insulation roperties of insulating materials atural rubber, asbestos or hygroscopic material not used Humidity conditioning Electric strength test was conducted after humidity test. age 12 of 67

13 E Report o.: R2XM Relative humidity (%), temperature ( C)... : RH: 93-95%, C, 120hrs (requested by client) Grade of insulation Insulation complies with subclauses 2.10, and Separation from hazardous voltages Method(s) used... : Method 1 and Method Clearances, creepage distances and distances through insulation General Internal power supply board has been approved, see table 1.5.1, other parts see below Frequency... : The frequency does not exceed 30kHz ollution degrees... : This report considered the pollution degree II Reduced values for functional insulation The functional insulation comply with c) Intervening unconnected conductive parts Insulation with varying dimensions Special separation requirements Insulation in circuits generating starting pulses Determination of working voltage General RMS working voltage (see appended table ) eak working voltage (see appended table ) Clearances General Mains transient voltages a) AC mains supply... : 2500Vp b) Earthed d.c. mains supplies... : c) Unearthed d.c. mains supplies... : d) Battery operation... : Clearances in primary circuits (see appended table and ) Clearances in secondary circuits Clearances in circuits having starting pulses Transients from a.c. mains supply... : Transients from d.c. mains supply... : age 13 of 67

14 E Report o.: R2XM Transients from telecommunication networks and cable distribution systems... : Measurement of transient voltage levels a) Transients from a mains supply For an a.c. mains supply... : For a d.c. mains supply... : b) Transients from a telecommunication network : Creepage distances General Material group and comparative tracking index CTI tests... : Material group IIIb is assumed to be used Minimum creepage distances (see appended table and ) Solid insulation See below General The insulation slices only used as basic insulation Distances through insulation Insulating compound as solid insulation Semiconductor devices Cemented joints Thin sheet material General Separable thin sheet material umber of layers (pcs)... : on-separable thin sheet material Thin sheet material standard test procedure Electric strength test Thin sheet material alternative test procedure Electric strength test Insulation in wound components Wire in wound components Working voltage... : a) Basic insulation not under stress... : b) Basic, supplementary, reinforced insulation... : c) Compliance with Annex U... : Two wires in contact inside wound component; angle between 45 and : age 14 of 67

15 E Report o.: R2XM Wire with solvent-based enamel in wound components Electric strength test Routine test Additional insulation in wound components Working voltage... : - Basic insulation not under stress... : - Supplementary, reinforced insulation... : Construction of printed boards See below Uncoated printed boards (see appended table and ) Coated printed boards Insulation between conductors on the same inner surface of a printed board Insulation between conductors on different layers of a printed board Distance through insulation umber of insulation layers (pcs)... : Component external terminations Tests on coated printed boards and coated components Sample preparation and preliminary inspection Thermal conditioning Electric strength test Abrasion resistance test Thermal cycling Test for ollution Degree 1 environment and insulating compound Tests for semiconductor devices and cemented joints Enclosed and sealed parts 3 WIRIG, COECTIOS AD SULY 3.1 General Current rating and overcurrent protection All the interconnecting cables and internal wires are adequate for the current they are intended to carry rotection against mechanical damage Wireways are smooth and free from sharp edges age 15 of 67

16 E Report o.: R2XM Securing of internal wiring The wires are positioned in such a manner that prevents excessive strain, loosening of terminal connections and damage of conductor insulation Insulation of conductors Beads and ceramic insulators Screws for electrical contact pressure A screw engage at least two completethreads into a metal plate Insulating materials in electrical connections Self-tapping and spaced thread screws o such screws Termination of conductors See below. 10 pull test Sleeving on wiring 3.2 Connection to a mains supply Means of connection See below Connection to an a.c. mains supply An appliance inlet for connection of a DETACHABLE OWER SULY CORD Connection to a d.c. mains supply o connection to d.c. mains supply Multiple supply connections ermanently connected equipment ot permanently connected equipment umber of conductors, diameter of cable and conduits (mm)... : Appliance inlets Approved AC inlet, (see appended table 1.5.1) ower supply cords See below AC power supply cords Type... : (see appended table 1.5.1) Rated current (A), cross-sectional area (mm 2 ), AWG... : age 16 of 67 (see appended table 1.5.1) DC power supply cords Cord anchorages and strain relief Mass of equipment (kg), pull ()... : Longitudinal displacement (mm)... :

17 E Report o.: R2XM rotection against mechanical damage Cord guards Diameter or minor dimension D (mm); test mass (g)... : Radius of curvature of cord (mm)... : Supply wiring space 3.3 Wiring terminals for connection of external conductors Wiring terminals Connection of non-detachable power supply cords Screw terminals Conductor sizes to be connected Rated current (A), cord/cable type, cross-sectional area (mm 2 )... : Wiring terminal sizes Rated current (A), type, nominal thread diameter (mm)... : Wiring terminal design Grouping of wiring terminals Stranded wire 3.4 Disconnection from the mains supply General requirement See below Disconnect devices Appliace inlet as the disconnect device ermanently connected equipment ot permanently connected equipment arts which remain energized Switches in flexible cords o such switch in flexible cords umber of poles single-phase and d.c. equipment Disconnect both poles simultaneously umber of poles three-phase equipment Switches as disconnect devices Complied lugs as disconnect devices Complied Interconnected equipment Multiple power sources 3.5 Interconnection of equipment age 17 of 67

18 E Report o.: R2XM General requirements Considered Types of interconnection circuits... : Interconnection circuits of SELV through the connector. o ELV interconnection circuits ELV circuits as interconnection circuits o ELV circuits Data ports for additional equipment Complied. 4 HYSICAL REQUIREMETS 4.1 Stability Angle of 10 Mass < 7kg Test force ()... : The unit is not floor-standing. 4.2 Mechanical strength General See below Rack-mounted equipment. Mass < 7kg Steady force test, 10 For internal components Steady force test, 30 o internal enclosure Steady force test, 250 For external enclosure Impact test 500g, 1.3m, no hazard. Fall test Top side and bottom side of enclosure Swing test Four vertical side of enclosure Drop test; height (mm)... : Stress relief test Cathode ray tubes o such tubes icture tube separately certified... : High pressure lamps o high pressure lamps Wall or ceiling mounted equipment; force ()... : 4.3 Design and construction Edges and corners All coners are smooth and rounded Handles and manual controls; force ()... : o such device Adjustable controls o adjustable controls Securing of parts o loosening of parts impairing creepage distances or clearances is likely to occur. age 18 of 67

19 E Report o.: R2XM Connection by plugs and sockets Employed in a manner not likely to creeate a hazard due to misconnection Direct plug-in equipment ot direct plug-in equipment Torque... : Compliance with the relevant mains plug standard... : Heating elements in earthed equipment o such component Batteries Button cell - Overcharging of a rechargeable battery - Unintentional charging of a non-rechargeable battery (See appended table 4.3.8) - Reverse charging of a rechargeable battery - Excessive discharging rate for any battery Consumer grade battery Oil and grease o oil and grease Dust, powders, liquids and gases Containers for liquids or gases Flammable liquids... : Quantity of liquid (l)... : Flash point ( C)... : Radiation See below General LEDs only for indication Ionizing radiation Measured radiation (a/kg)... : Measured high-voltage (kv)... : Measured focus voltage (kv)... : CRT markings... : Effect of ultraviolet (UV) radiation on materials art, property, retention after test, flammability classification... : Human exposure to ultraviolet (UV) radiation... : Lasers (including laser diodes) and LEDs LEDs only for indication Lasers (including laser diodes) Laser class... : Light emitting diodes (LEDs) LEDs only for indication Other types... : 4.4 rotection against hazardous moving parts age 19 of 67

20 E Report o.: R2XM General o moving parts rotection in operator access areas... : Household and home/office document/media shredders rotection in restricted access locations... : rotection in service access areas rotection against moving fan blades General ot considered to cause pain or injury. A).: Is considered to cause pain, not injury. B) : Considered to cause injury. C) : rotection for users Use of symbol or warning.. : rotection for service persons Use of symbol or warning... : 4.5 Thermal requirements General See below Temperature tests (see appended table 4.5) ormal load condition per Annex L... : Temperature limits for materials (see appended table 4.5) Touch temperature limits (see appended table 4.5) Resistance to abnormal heat... : (see appended table 4.5.5) 4.6 Openings in enclosures Top and side openings Side openings Dimensions (mm)... : age 20 of 67 The any dimensions of openings are less than 5 mm Bottoms of fire enclosures o opening Construction of the bottomm, dimensions (mm).. : Doors or covers in fire enclosures Openings in transportable equipment Constructional design measures Dimensions (mm)... : Evaluation measures for larger openings Use of metallized parts Adhesives for constructional purposes

21 E Report o.: R2XM Conditioning temperature ( C), time (weeks)... : 4.7 Resistance to fire Reducing the risk of ignition and spread of flame See below. Method 1, selection and application of components wiring and materials Method 2, application of all of simulated fault condition tests Materials with the required flammability classes are usedsee appended table and Conditions for a fire enclosure See below arts requiring a fire enclosure arts not requiring a fire enclosure Materials General See below Materials for fire enclosures Metal enclosure Materials for components and other parts outside fire enclosures Materials for components and other parts inside fire enclosures (see appended table 1.5.1) Materials for air filter assemblies o air filters in the equipment Materials used in high-voltage components o parts exceeding 4kV. 5 ELECTRICAL REQUIREMETS AD SIMULATED ABORMAL CODITIOS 5.1 Touch current and protective conductor current General See below Configuration of equipment under test (EUT) See below Single connection to an a.c. mains supply Considered Redundant multiple connections to an a.c. mains supply Simultaneous multiple connections to an a.c. mains supply Test circuit Figure 5A Application of measuring instrument Test procedure Test measurements Supply voltage (V)... : 264V, 60Hz Measured touch current (ma)... : (see appended table 5.1) Max. Allowed touch current (ma)... : (see appended table 5.1) age 21 of 67

22 E Report o.: R2XM Measured protective conductor current (ma)... : Max. Allowed protective conductor current (ma).. : Equipment with touch current exceeding 3,5 ma General... : Simultaneous multiple connections to the supply Touch currents to telecommunication networks and cable distribution systems and from telecommunication networks Limitation of the touch current to a telecommunication network or to a cable distribution system Supply voltage (V)... : Measured touch current (Ma)... : Max. Allowed touch current (Ma)... : Summation of touch currents from telecommunication networks a) EUT with earthed telecommunication ports... : b) EUT whose telecommunication ports have no reference to protective earth 5.2 Electric strength General Test procedure (See appended table 5.2) 5.3 Abnormal operating and fault conditions rotection against overload and abnormal operation age 22 of 67 (See appended table 5.3) Motors o such component Transformers Transformers be evaluated in approved switching power supply Functional insulation... : Complies with c) Electromechanical components o such component Audio amplifiers in ITE... : Simulation of faults (see appended table 5.3) Unattended equipment Compliance criteria for abnormal operating and fault conditions (see appended table 5.3) During the tests o hazard.

23 E Report o.: R2XM After the tests o hazard. 6 COECTIO TO TELECOMMUICATIO ETWORKS 6.1 rotection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment rotection from hazardous voltages Separation of the telecommunication network from earth Requirements Supply voltage (V)... : Current in the test circuit (Ma)... : Exclusions... : 6.2 rotection of equipment users from overvoltages on telecommunication networks Separation requirements Electric strength test procedure See below Impulse test Steady-state test See appended table Compliance criteria 6.3 rotection of the telecommunication wiring system from overheating Max. Output current (A)... : Current limiting method... : 7 COECTIO TO CABLE DISTRIBUTIO SYSTEMS 7.1 General o connected to cable distribution system. 7.2 rotection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment 7.3 rotection of equipment users from overvoltages on the cable distribution system 7.4 Insulation between primary circuits and cable distribution systems General Voltage surge test Impulse test age 23 of 67

24 E Report o.: R2XM A AEX A, TESTS FOR RESISTACE TO HEAT AD FIRE A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see ) A.1.1 Samples... : Wall thickness (mm)... : A.1.2 Conditioning of samples; temperature ( C)... : A.1.3 Mounting of samples... : A.1.4 Test flame (see IEC ) Flame A, B, C or D... : A.1.5 Test procedure A.1.6 Compliance criteria Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... : A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see and ) A.2.1 Samples, material... : Wall thickness (mm)... : A.2.2 Conditioning of samples; temperature ( C)... : A.2.3 Mounting of samples... : A.2.4 Test flame (see IEC ) Flame A, B or C... : A.2.5 Test procedure A.2.6 Compliance criteria Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... : A.2.7 Alternative test acc. To IEC , cl. 5 and 9 Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... : A.3 Hot flaming oil test (see 4.6.2) A.3.1 Mounting of samples A.3.2 Test procedure A.3.3 Compliance criterion age 24 of 67

25 E Report o.: R2XM B AEX B, MOTOR TESTS UDER ABORMAL CODITIOS (see and 5.3.2) B.1 General requirements osition... : Manufacturer... : Type... : Rated values... : B.2 Test conditions B.3 Maximum temperatures B.4 Running overload test B.5 Locked-rotor overload test Test duration (days)... : Electric strength test: test voltage (V)... : B.6 Running overload test for d.c. motors in secondary circuits B.6.1 General B.6.2 Test procedure B.6.3 Alternative test procedure B.6.4 Electric strength test; test voltage (V)... : B.7 Locked-rotor overload test for d.c. motors in secondary circuits B.7.1 General B.7.2 Test procedure B.7.3 Alternative test procedure B.7.4 Electric strength test; test voltage (V)... : B.8 Test for motors with capacitors B.9 Test for three-phase motors B.10 Test for series motors Operating voltage (V)... : C AEX C, TRASFORMERS (see and 5.3.3) osition... : age 25 of 67 Transformer have been evaluated in approved switching power supply, see appended table Manufacturer... : Type... : Rated values... :

26 E Report o.: R2XM Method of protection... : C.1 Overload test C.2 Insulation rotection from displacement of windings... : D AEX D, MEASURIG ISTRUMETS FOR TOUCH-CURRET TESTS (see 5.1.4) D.1 Measuring instrument D.2 Alternative measuring instrument E AEX E, TEMERATURE RISE OF A WIDIG (see ) F AEX F, MEASUREMET OF CLEARACES AD CREEAGE DISTACES (see 2.10 and Annex G) G AEX G, ALTERATIVE METHOD FOR DETERMIIG MIIMUM CLEARACES G.1 Clearances G.1.1 General G.1.2 Summary of the procedure for determining minimum clearances G.2 Determination of mains transient voltage (V) G.2.1 AC mains supply... : G.2.2 Earthed d.c. mains supplies... : G.2.3 Unearthed d.c. mains supplies... : G.2.4 Battery operation... : G.3 Determination of telecommunication network transient voltage (V)... : G.4 Determination of required withstand voltage (V) G.4.1 Mains transients and internal repetitive peaks... : G.4.2 Transients from telecommunication networks... : G.4.3 Combination of transients G.4.4 Transients from cable distribution systems G.5 Measurement of transient voltages (V) a) Transients from a mains supply For an a.c. mains supply For a d.c. mains supply b) Transients from a telecommunication network age 26 of 67

27 E Report o.: R2XM G.6 Determination of minimum clearances... : H AEX H, IOIZIG RADIATIO (see ) J AEX J, TABLE OF ELECTROCHEMICAL OTETIALS (see ) Metal(s) used... : 1018A carbon steel K AEX K, THERMAL COTROLS (see and 5.3.8) K.1 Making and breaking capacity K.2 Thermostat reliability; operating voltage (V)... : K.3 Thermostat endurance test; operating voltage (V)... : K.4 Temperature limiter endurance; operating voltage (V)... : K.5 Thermal cut-out reliability K.6 Stability of operation L AEX L, ORMAL LOAD CODITIOS FOR SOME TYES OF ELECTRICAL BUSIESS EQUIMET (see and 4.5.2) L.1 Typewriters L.2 Adding machines and cash registers L.3 Erasers L.4 encil sharpeners L.5 Duplicators and copy machines L.6 Motor-operated files L.7 Other business equipment (See appended table 1.6.2) M AEX M, CRITERIA FOR TELEHOE RIGIG SIGALS (see 2.3.1) M.1 Introduction Method A is used age 27 of 67

28 E Report o.: R2XM M.2 Method A Test Data: ort 1 TI1 to RIG1: t1=2s, t2=6s, Vpp=172V, Ipp=172/5000=34.4mA, Vdc=48V, Idc=48/5000=9.6mA, Formula of ITS1, ITS2 (for t1 1.2s) ITS1=12.164mA ITS2=7.327mA Result: a) For normal operation: ITS1=12.164mA<16mA; b) For normal operation: ITS2=7.327mA<16mA; c) Under single fault conditions: C1 short circuit, U2 pin (4-5) short circuit,: no change, the related value as same as normal condition, ITS1 and/or ITS2<20mA M.3 Method B M.3.1 Ringing signal M Frequency (Hz)... : M Voltage (V)... : M Cadence; time (s), voltage (V)... : M Single fault current (Ma)... : M.3.2 Tripping device and monitoring voltage... : M Conditions for use of a tripping device or a monitoring voltage M Tripping device M Monitoring voltage (V)... : AEX, IMULSE TEST GEERATORS (see , , , , 7.3.2, and Clause G.5).1 ITU-T impulse test generators.2 IEC impulse test generator AEX, ORMATIVE REFERECES age 28 of 67

29 E Report o.: R2XM Q AEX Q, Voltage dependent resistors (VDRs) (see ) - referred climatic categories... : Complied - Maximum continuous voltage... : Complied - Combination pulse current... : Complied Body of the VDR Test according to IEC : Body of the VDR. Flammability class of material ( min V-1)...: R AEX R, EXAMLES OF REQUIREMETS FOR QUALITY COTROL ROGRAMMES R.1 Minimum separation distances for unpopulated coated printed boards (see ) R.2 Reduced clearances (see ) S AEX S, ROCEDURE FOR IMULSE TESTIG (see ) S.1 Test equipment S.2 Test procedure S.3 Examples of waveforms during impulse testing T AEX T, GUIDACE O ROTECTIO AGAIST IGRESS OF WATER (see 1.1.2) U AEX U, ISULATED WIDIG WIRES FOR USE WITHOUT ITERLEAVED ISULATIO (see ) V AEX V, AC OWER DISTRIBUTIO SYSTEMS (see 1.6.1) V.1 Introduction V.2 T power distribution systems W AEX W, SUMMATIO OF TOUCH CURRETS W.1 Touch current from electronic circuits W.1.1 Floating circuits W.1.2 Earthed circuits W.2 Interconnection of several equipments W.2.1 Isolation age 29 of 67

30 E Report o.: R2XM W.2.2 Common return, isolated from earth W.2.3 Common return, connected to protective earth X AEX X, MAXIMUM HEATIG EFFECT I TRASFORMER TESTS (see clause C.1) X.1 Determination of maximum input current X.2 Overload test procedure Y AEX Y, ULTRAVIOLET LIGHT CODITIOIG TEST (see ) Y.1 Test apparatus...: Y.2 Mounting of test samples...: Y.3 Carbon-arc light-exposure apparatus...: Y.4 Xenon-arc light exposure apparatus...: Z AEX Z, OVERVOLTAGE CATEGORIES (see and Clause G.2) AA AEX AA, MADREL TEST (see ) BB AEX BB, CHAGES I THE SECOD EDITIO CC AEX CC, Evaluation of integrated circuit (IC) current limiters CC.1 General CC.2 Test program 1.: CC.3 Test program 2.: CC.4 Test program 3...: CC.5 Compliance...: DD AEX DD, Requirements for the mounting means of rack-mounted equipment DD.1 General DD.2 Mechanical strength test, variable..: DD.3 Mechanical strength test, 250, including end stops : DD.4 Compliance...: EE AEX EE, Household and home/office document/media shredders EE.1 General age 30 of 67

31 E Report o.: R2XM EE.2 Markings and instructions Use of markings or symbols : Information of user instructions, maintenance and/or servicing instructions : EE.3 Inadvertent reactivation test : EE.4 Disconnection of power to hazardous moving parts: Use of markings or symbols : EE.5 rotection against hazardous moving parts Test with test finger (Figure 2A) : Test with wedge probe (Figure EE1 and EE2) : age 31 of 67

32 E Report o.: R2XM Group differences COMMO MODIFICATIOS FOR E :2006+A11:2009+A1:2010+A12:2011+A2:2013 Contents Contents (A2:2013) Whole document (A2:2013) General General (A1:2010) (A1:2010) Add the following annexes: Annex ZA (normative) ormative references to international publications with their corresponding European publications Annex ZB (normative) Special national conditions Annex ZC (informative) A-deviations Add the following: Annex ZD (informative) IEC and CEELEC code designations for flexible cords Delete all the country notes in the reference document according to the following list: ote * ote ote * ote of secretary: Text of Common Modification remains unchanged For special national conditions, see Annex ZB. Delete all the country notes in the reference document according to the following list: ote ote 2 & ote ote ote ote 4, 5 & ote ote ote ote ote ote 2 & ote ote ote ote ote ote ote 1 & ote ote ote ote 3 & ote 1 6 ote 2 & ote ote ote ote ote 7.1 ote ote 7.3 ote 1 & 2 G.2.1 ote 2 Annex H ote 2 In IEC :2005/A1 delete all the country notes according to the following list: : ote : ote : ote 2 - EE.3: ote Replace the text of OTE 3 by the following OTE 3 The requirements of E may also be used to meet safety requirements for multimedia equipment. See IEC Guide 112, Guide on the safety of multimedia equipment. For television sets E applies. age 32 of 67

33 E Report o.: R2XM (A1:2010) 1.3.Z1 Add the following definition: Z1 ORTABLE SOUD SYSTEM small battery powered audio equipment: whose prime purpose is to listen to recorded or broadcasted sound; and that uses headphones or earphones that can be worn in or on or around the ears; and that allows the user to walk around OTE Examples are mini-disk or CD players; M3 audio players or similar equipment. Add the following subclause: 1.3.Z1 Exposure to excessive sound pressure The apparatus shall be so designed and constructed as to present no danger when used for its intended purpose, either in normal operating conditions or under fault conditions, particularly providing protection against exposure to excessive sound pressures from headphones or earphones. OTE Z1 A new method of measurement is described in E , Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - art 1: General method for one package equipment, and in E , Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - art 2: Guidelines to associate sets with headphones coming from different manufacturers Add the following OTE: OTE Z1 The use of certain substances in electrical and electronic equipment is restricted within the EU: see Directive 2002/95/EC Add the following OTE: OTE Z1 In addition, the instructions shall include, as far as applicable, a warning that excessive sound pressure from earphones and headphones can cause hearing loss age 33 of 67

34 E Report o.: R2XM (A1:2010) Delete OTE Z1. Add the following paragraph at the end of the subclause: In addition, for a ORTABLE SOUD SYSTEM, the instructions shall include a warning that excessive sound pressure from earphones and headphones can cause hearing loss Replace the subclause as follows: Basic requirements To protect against excessive current, short-circuits and earth faults in RIMARY CIRCUITS, protective devices shall be included either as integral parts of the equipment or as parts of the building installation, subject to the following, a), b) and c): a) except as detailed in b) and c), protective devices necessary to comply with the requirements of 5.3 shall be included as parts of the equipment; b) for components in series with the mains input to the equipment such as the supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault protection may be provided by protective devices in the building installation; c) it is permitted for LUGGABLE EQUIMET TYE B or ERMAETLY COECTED EQUIMET, to rely on dedicated overcurrent and short-circuit protection in the building installation, provided that the means of protection, e.g. fuses or circuit breakers, is fully specified in the installation instructions. If reliance is placed on protection in the building installation, the installation instructions shall so state, except that for LUGGABLE EQUIMET TYE A the building installation shall be regarded as providing protection in accordance with the rating of the wall socket outlet This subclause has been declared void Delete the OTE in Table 3A, and delete also in this table the conduit sizes in parentheses. age 34 of 67

35 E Report o.: R2XM Replace IEC 53 by H05 RR-F ; IEC 52 by H03 VV-F or H03 VVH2-F ; IEC 53 by H05 VV-F or H05 VVH2-F2. In Table 3B, replace the first four lines by the following: Up to and including 6 0,75 a) Over 6 up to and including 10 (0,75) b) 1,0 Over 10 up to and including 16 (1,0) c) 1,5 In the conditions applicable to Table 3B delete the words in some countries in condition a). In OTE 1, applicable to Table 3B, delete the second sentence (A2:2013) Add the following ote: OTE Z1 The harmonised code designations corresponding to the IEC cord types are given in Annex ZD In Table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace with the following: Over 10 up to and including 16 1,5 to 2,5 1,5 to 4 Delete the fifth line: conductor sizes for 13 to 16 A Add the following OTE: OTE Z1 Attention is drawn to 1999/519/EC: Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz. Standards taking into account this Recommendation which demonstrate compliance with the applicable EU Directive are indicated in the OJEC (A1:2010) Replace the existing OTE by the following: OTE Z1 Attention is drawn to: 1999/519/EC: Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz, and 2006/25/EC: Directive on the minimum health and safety requirements regarding the exposure of workers to risks arising from physical agents (artificial optical radiation). Standards taking into account mentioned Recommendation and Directive which demonstrate compliance with the applicable EU Directive are indicated in the OJEC. age 35 of 67

36 E Report o.: R2XM Annex H Bibliography Replace the last paragraph of this annex by: At any point 10 cm from the surface of the OERATOR ACCESS AREA, the dose rate shall not exceed 1 μsv/h (0,1 mr/h) (see OTE). Account is taken of the background level. Replace the notes as follows: OTE These values appear in Directive 96/29/Euratom. Delete OTE 2. Add the following standards: E :2000, Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - art 1: General method for one package equipment E :2003, Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - art 2: Matching of sets with headphones if either or both are offered separately Add the following notes for the standards indicated: IEC OTE Harmonized in E series (not modified). IEC OTE Harmonized as HD :2005 (modified). IEC OTE Harmonized as HD S2:1996 (modified). IEC OTE Harmonized as E 60529:1991 (not modified). IEC OTE Harmonized as E :2006 (not modified). IEC OTE Harmonized as E :2005 (modified). IEC OTE Harmonized as E :2004 (not modified). IEC OTE Harmonized as E :2004 (not modified). IEC OTE Harmonized as E 61032:1998 (not modified). age 36 of 67

37 E Report o.: R2XM Bibliography (A1:2010) IEC OTE Harmonized as E 61140:2002 (not modified). IEC OTE Harmonized as E :2005 (not modified). IEC OTE Harmonized as E :2001 (not modified). IEC OTE Harmonized as E :2001 (not modified). IEC OTE Harmonized as E :2002 (not modified). IEC OTE Harmonized as E :2003 (not modified). IEC OTE Harmonized as E 61965:2003 (not modified). ISO 4892 OTE Harmonized in E ISO 4892 series (not modified). Add the following note for the standard indicated: IEC OTE Harmonized as E ZA (A2:2013) ormative references to international publications with their corresponding European publications ZB Special national conditions Special national condition: ational characteristic or practice that cannot be changed even over a long period, e.g. climatic conditions, electrical earthing conditions. OTE If it affects harmonization, it forms part of the European Standard. For the countries in which the relevant special national conditions apply these provisions are normative, for other countries they are informative In Denmark, certain types of Class I appliances (see ) may be provided with a plug not establishing earthing conditions when inserted into Danish socket-outlets (A11:2009) (A11:2009) Add as new SC: In orway and Sweden, for requirements see and 7.3 of this annex. Replace the existing SC by the following: In Finland, orway and Sweden, resistors bridging BASIC ISULATIO in CLASS I LUGGABLE EQUIMET TYE A must comply with the requirements in In addition when a single resistor is used, the resistor must withstand the resistor test in age 37 of 67

38 E Report o.: R2XM In orway, due to the IT power system used (see annex V, Figure V.7), capacitors are required to be rated for the applicable line-to-line voltage (230 V) In Finland, orway and Sweden, the third dashed sentence is applicable only to equipment as defined in of this annex (A2:2013) (A2:2013) In Denmark, Finland, orway and Sweden, CLASS I LUGGABLE EQUIMET TYE A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text in the applicable countries shall be as follows: In Denmark: Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til stikproppens jord. In Finland: "Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan" In orway: Apparatet må tilkoples jordet stikkontakt In Sweden: Apparaten skall anslutas till jordat uttag In Denmark, socket-outlets for providing power to other equipment shall be in accordance with the DS D1:2011. For class I equipment the following Standard Sheets are applicable: DK 1-3a, DK 1-1c, DK 1-1d, DK 1-5a or DK 1-7a, with the exception for STATIOARY EQUIMET where the socketoutlets shall be in accordance with Standard Sheet DK 1-1b, DK 1-1c, DK 1-1d or DK 1-5a. Socket outlets intended for providing power to Class II apparatus with a rated current of 2,5 A shall be in accordance with DS D1 standard sheet DKA 1-4a. Other current rating socket outlets shall be in compliance with by DS D1 Standard Sheet DKA 1-3a or DKA 1-3b. Justification the Heavy Current Regulations, 6c In orway, for requirements see , and of this annex. age 38 of 67

39 E Report o.: R2XM In Finland, orway and Sweden there are additional requirements for the insulation. See and of this annex In orway, for requirements see , and of this annex In the United Kingdom, the current rating of the circuit shall be taken as 13 A, not 16 A In the United Kingdom, to protect against excessive currents and short-circuits in the RIMARY CIRCUIT of DIRECT LUG-I EQUIMET, tests according to 5.3 shall be conducted, using an external protective device rated 30 A or 32 A. If these tests fail, suitable protective devices shall be included as integral parts of the DIRECT LUG-I EQUIMET, so that the requirements of 5.3 are met In Finland, orway and Sweden, there are additional requirements for the insulation, see and of this annex In Switzerland, supply cords of equipment having a RATED CURRET not exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC and one of the following dimension sheets: SEV lug Type E 250/400 V, 10 A SEV lug Type 11 L+ 250 V, 10 A SEV lug Type 12 L++E 250 V, 10 A In general, E applies for plugs for currents exceeding 10 A. However, a 16 A plug and socketoutlet system is being introduced in Switzerland, the plugs of which are according to the following dimension sheets, published in February 1998: SEV lug Type 25 3L++E 230/400 V, 16 A SEV lug Type 21 L+ 250 V, 16 A SEV lug Type 23 L++E 250 V, 16 A age 39 of 67

40 E Report o.: R2XM (A2:2013) In Denmark, supply cords of single-phase equipment having a rated current not exceeding 13 A shall be provided with a plug according to DS D1. CLASS I EQUIMET provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a. If a single-phase equipment having a RATED CURRET exceeding 13 A or if a poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with the standard sheets DK 6-1a in DS D1 or E Justification the Heavy Current Regulations, 6c In Spain, supply cords of single-phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to UE 20315:1994. Supply cords of single-phase equipment having a rated current not exceeding 2,5 A shall be provided with a plug according to UE-E 50075:1993. CLASS I EQUIMET provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules, shall be provided with a plug in accordance with standard UE 20315:1994. If poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with UE-E In the United Kingdom, apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug, shall be fitted with a standard plug in accordance with Statutory Instrument 1768: The lugs and Sockets etc. (Safety) Regulations 1994, unless exempted by those regulations. OTE Standard plug is defined in SI 1768:1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug. age 40 of 67

41 E Report o.: R2XM In Ireland, apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to I.S. 411 by means of that flexible cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory Instrument 525: ational Standards Authority of Ireland (section 28) (13 A lugs and Conversion Adaptors for Domestic Use) Regulations In Switzerland, for requirements see of this annex In the United Kingdom, a power supply cord with conductor of 1,25 mm 2 is allowed for equipment with a rated current over 10 A and up to and including 13 A In the United Kingdom, the range of conductor sizes of flexible cords to be accepted by terminals for equipment with a RATED CURRET of over 10 A up to and including 13 A is: 1,25 mm 2 to 1,5 mm 2 nominal cross-sectional area In the United Kingdom, the torque test is performed using a socket outlet complying with BS 1363 part 1:1995, including Amendment 1:1997 and Amendment 2:2003 and the plug part of DIRECT LUG-I EQUIMET shall be assessed to BS 1363: art 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, and 12.17, except that the test of is performed at not less than 125 C. Where the metal earth pin is replaced by an Insulated Shutter Opening Device (ISOD), the requirements of clauses 22.2 and 23 also apply In Ireland, DIRECT LUG-I EQUIMET is known as plug similar devices. Such devices shall comply with Statutory Instrument 526: ational Standards Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets for domestic use) Regulations, age 41 of 67

42 E Report o.: R2XM In Finland, orway and Sweden TOUCH CURRET measurement results exceeding 3,5 ma r.m.s. are permitted only for the following equipment: STATIOARY LUGGABLE EQUIMET TYE A that is intended to be used in a RESTRICTED ACCESS LOCATIO where equipotential bonding has been applied, for example, in a telecommunication centre; and has provision for a permanently connected ROTECTIVE EARTHIG CODUCTOR; and is provided with instructions for the installation of that conductor by a SERVICE ERSO; STATIOARY LUGGABLE EQUIMET TYE B; STATIOARY ERMAETLY COECTED EQUIMET. age 42 of 67

43 E Report o.: R2XM (A1:2010) In Finland, orway and Sweden, add the following text between the first and second paragraph of the compliance clause: If this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which shall pass the electric strength test below, or - one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. Alternatively for components, there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing, so that CLEARACES and CREEAGE DISTACES do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition - passes the tests and inspection criteria of with an electric strength test of 1,5 kv multiplied by 1,6 (the electric strength test of shall be performed using 1,5 kv), and - is subject to ROUTIE TESTIG for electric strength during manufacturing, using a test voltage of 1,5 kv. It is permitted to bridge this insulation with an optocoupler complying with b). It is permitted to bridge this insulation with a capacitor complying with E :2005, subclass Y2. A capacitor classified Y3 according to E :2005, may bridge this insulation under the following conditions: - the insulation requirements are satisfied by having a capacitor classified Y3 as defined by E , which in addition to the Y3 testing, is tested with an impulse test of 2,5 kv defined in E :2006, ; - the additional testing shall be performed on all the test specimens as described in E ; - the impulse test of 2,5 kv is to be performed before the endurance test in E , in the sequence of tests as described in E age 43 of 67

44 E Report o.: R2XM In Finland, orway and Sweden, the exclusions are applicable for ERMAETLY COECTED EQUIMET, LUGGABLE EQUIMET TYE B and equipment intended to be used in a RESTRICTED ACCESS LOCATIO where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected ROTECTIVE EARTHIG CODUCTOR and is provided with instructions for the installation of that conductor by a SERVICE ERSO. 7.2 In Finland, orway and Sweden, for requirements see and of this annex. The term TELECOMMUICATIO ETWORK in being replaced by the term CABLE DISTRIBUTIO SYSTEM. 7.3 (A11:2009) Delete the existing SC for orway and Sweden (based on OTE 1 of IEC : corr. 1). Add as new SC (based on future OTE 3 of IEC :200X): In orway and Sweden, for requirements see and of this annex. 7.3 In orway, for installation conditions see E :2005. ZC A-deviations A-deviation: ational deviation due to regulations, the alteration of which is for the time being outside the competence of the CEELEC national member. This European Standard falls under Directives RTTED (1999/5/EC) and LVD (2006/95/EC). OTE (from CE/CEELEC IR art 2:2002, 2.17) Where standards fall under EC Directives, it is the view of the Commission of the European Communities (OJ o C 59, ) that the effect of the decision of the Court of Justice in case 815/79 Cremonini/Vrankovich (European Court Reports 1980, p. 3583) is that compliance with A-deviations is no longer mandatory and that the free movement of products complying with such a standard should not be restricted except under the safeguard procedure provided for in the relevant Directive. A-deviations in an EFTA-country are valid instead of the relevant provisions of the European Standard in that country until they have been removed Switzerland (Ordinance on environmentally hazardous substances SR , Annex 1.7, Mercury - Annex 1.7 of SR applies for mercury.) Add the following: OTE In Switzerland, switches containing mercury such as thermostats, relays and level controllers are not allowed. age 44 of 67

45 E Report o.: R2XM Germany (Gesetz über technische Arbeitsmittel und Verbraucherprodukte (Geräte- und roduktsicherheitsgesetz - GSG) [Law on technical labour equipment and consumer products], of 6th January 2004, Section 2, Article 4, Clause (4), Item 2). If for the assurance of safety and health certain rules during use, amending or maintenance of a technical labour equipment or readymade consumer product are to be followed, a manual in German language has to be delivered when placing the product on the market. Of this requirement, rules for use even only by SERVICE ERSOS are not exempted Switzerland (Ordinance on chemical hazardous risk reduction SR , Annex 2.15 Batteries) Annex 2.15 of SR applies for batteries. (A12:2011) Zx. rotection against excessive sound pressure from personal music players age 45 of 67

46 E Report o.: R2XM Zx.1 General This sub-clause specifies requirements for protection against excessive sound pressure from personal music players that are closely coupled to the ear. It also specifies requirements for earphones and headphones intended for use with personal music players. A personal music player is a portable equipment for personal use, that: - is designed to allow the user to listen to recorded or broadcast sound or video; and - primarily uses headphones or earphones that can be worn in or on or around the ears; and - allows the user to walk around while in use. OTE 1 Examples are hand-held or body-worn portable CD players, M3 audio players, mobile phones with M3 type features, DA$s or similar equipment. A personal music player and earphones or headphones intended to be used with personal music players shall comply with the requirements of this sub-clause. The requirements in this sub-clause are valid for music or video mode only. The requirements do not apply: - while the personal music player is connected to an external amplifier; or - while the headphones or earphones are not used. OTE 2 An external amplifier is an amplifier which is not part of the personal music player or the listening device, but which is intended to play the music as a standalone music player. The requirements do not apply to: - hearing aid equipment and professional equipment; OTE 3 rofessional equipment is equipment sold through special sales channels. All products sold through normal electronics stores are considered not to be professional equipment. age 46 of 67

47 E Report o.: R2XM analogue personal music players (personal music players without any kind of digital processing of the sound signal) that are brought to the market before the end of 2015 OTE 4 This exemption has been allowed because this technology is falling out of use and it is expected that within a few years it will no longer exist. This exemption will not be extended to other technologies. For equipment which is clearly designed or intended for use by young children, the limits of E 71-1 apply. age 47 of 67

48 E Report o.: R2XM Zx.2 Equipment requirements o safety provision is required for equipment that complies with the following: - equipment provided as a package (personal music player with its listening device), where the acoustic output L Aeq,T is 85 dba measured while playing the fixed programme simulation noise" as described in E ; and - a personal music player provided with an analogue electrical output socket for a listening device, where the electrical output is 27 mv measured as described in E , while playing the fixed programme simulation noise" as described in E OTE 1 Wherever the term acoustic output is used in this clause, the 30 s A-weighted equivalent sound pressure level L Aeq,T is meant. See also Zx.5 and Annex Zx. All other equipment shall: a) protect the user from unintentional acoustic outputs exceeding those mentioned above; and b) have a standard acoustic output level not exceeding those mentioned above, and automatically return to an output level not exceeding those mentioned above when the power is switched off; and c) provide a means to actively inform the user of the increased sound pressure when the equipment is operated with an acoustic output exceeding those mentioned above. Any means used shall be acknowledged by the user before activating a mode of operation which allows for an acoustic output exceeding those mentioned above. The acknowledgement does not need to be repeated more than once every 20 h of cumulative listening time; and OTE 2 Examples of means include visual or audible signals. Action from the user is always required. age 48 of 67

49 E Report o.: R2XM OTE 3 The 20 h listening time is the accumulative listening time, independent how often and how long the personal music player has been switched off. d) have a warning as specified in Zx.3; and e) not exceed the following: 1) equipment provided as a package (player with its listening device), the acoustic output shall be 100 dba measured while playing the fixed programme simulation noise" described in E ; and 2) a personal music player provided with an analogue electrical output socket for a listening device, the electrical output shall be 150 mv measured as described in E , while playing the fixed programme simulation noise" described in E For music where the average sound pressure (long term L Aeq,T ) measured over the duration of the song is lower than the average produced by the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dba. In this case T becomes the duration of the song. OTE 4 Classical music typically has an average sound pressure (long term L Aeq,T ) which is much lower than the average programme simulation noise. Therefore, if the player is capable to analyse the song and compare it with the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dba. For example, if the player is set with the programme simulation noise to 85 dba, but the average music level of the song is only 65 dba, there is no need to give a warning or ask an acknowledgement as long as the average sound level of the song is not above the basic limit of 85 dba. age 49 of 67

50 E Report o.: R2XM Zx.3 Warning The warning shall be placed on the equipment, or on the packaging, or in the instruction manual and shall consist of the following: - the symbol of Figure 1 with a minimum height of 5 mm; and - the following wording, or similar: To prevent possible hearing damage, do not listen at high volume levels for long periods. Alternatively, the entire warning may be given through the equipment display during use, when the user is asked to acknowledge activation of the higher level. Zx.4 Requirements for listening devices (headphones and earphones) Zx.4.1 Wired listening devices with analogue input With 94 dba sound pressure output L Aeq,T, the input voltage of the fixed programme simulation noise" described in E shall be 75 mv. This requirement is applicable in any mode where the headphones can operate (active or passive), including any available setting (for example built-in volume level control). OTE The values of 94 dba - 75 mv correspond with 85dBA - 27 mv and 100 dba mv. age 50 of 67

51 E Report o.: R2XM Zx.4.2 Wired listening devices with digital input With any playing device playing the fixed programme simulation noise" described in E (and respecting the digital interface standards, where a digital interface standard exists that specifies the equivalent acoustic level), the acoustic output L Aeq,T of the listening device shall be 100 dba. This requirement is applicable in any mode where the headphones can operate, including any available setting (for example built-in volume level control, additional sound feature like equalization, etc.). OTE An example of a wired listening device with digital input is a USB headphone. Zx.4.3 Wireless listening devices In wireless mode: - with any playing and transmitting device playing the fixed programme simulation noise described in E ; and - respecting the wireless transmission standards, where an air interface standard exists that specifies the equivalent acoustic level; and - with volume and sound settings in the listening device (for example built-in volume level control, additional sound feature like equalization, etc.) set to the combination of positions that maximize the measured acoustic output for the above-mentioned programme simulation noise, the acoustic output L Aeq,T of the listening device shall be 100 dba. OTE An example of a wireless listening device is a Bluetooth headphone. Zx.5 Measurement methods Measurements shall be made in accordance with E or E as applicable. Unless stated otherwise, the time interval T shall be 30 s. OTE Test method for wireless equipment provided without listening device should be defined. age 51 of 67

52 E Report o.: R2XM Annex Zx (A12:2011) Significance of L Aeq,T in E and additional information L Aeq,T is derived from the general formula for equivalent sound pressure: This can be represented graphically as follows: In E the measurement time interval (t2 -t1) is 30 s. In practice, and for the purposes of listening to personal music player content, L Aeq,T has a time interval T (t2 - t1) in the order of minutes / hours and not seconds. 6.5 (Limitation value) of E :2000 acknowledges this fact and states that the 100 db limit equates to a long time average of 90 db L Aeq,T. By using the IEC programme simulation noise" test signal, this also takes the spectral content into account. The SCEHIR 1 report states that 80 dba is considered safe for an exposure time of 40 h/week. Most persons do not listen to 40 h/week to their personal music player. In addition, not all music tracks are at the same level of the simulated noise signal. Whilst modern music tends to be at around the same level, most of the available music is at a lower average level. Therefore, the working group 2 considers a value of 85 dba to be safe for an overwhelming majority of the users of personal music players. age 52 of 67

53 E Report o.: R2XM SCEIHR opinion of 23 Sept 2008: otential health risks of exposure to noise from personal music players and mobile phones including a music playing function 2 CEELEC TC108X/WG03 ZD IEC and CEELEC code designations for flexible cords Type of flexible cord Code designations IEC CEELEC VC insulated cords Flat twin tinsel cord IEC 41 H03VH-Y Light polyvinyl chloride sheathed flexible cord IEC 52 H03VV-F H03VVH2-F Ordinary polyvinyl chloride sheathed flexible cord IEC 53 H05VV-F H05VVH2-F Rubber insulated cords Braided cord IEC 51 H03RT-F Ordinary tough rubber sheathed flexible cord IEC 53 H05RR-F Ordinary polychloroprene sheathed flexible IEC 57 H05R-F cord Heavy polychloroprene sheathed flexible cord IEC 66 H07R-F Cords having high flexibility Rubber insulated and sheathed cord IEC 86 H03RR-H Rubber insulated, crosslinked VC sheathed IEC 87 H03RV4-H cord Crosslinked VC insulated and sheathed cord IEC 88 H03V4V4-H age 53 of 67

54 E Report o.: R2XM TABLE: List of critical components Object/part o. lug of power cord Flexible cable of power cord Connector of power cord Appliance inlet ower switch Metal enclosure Internal AC input wire Heat shrinkable tube Internal AC connector Switching ower Supply Insulation sheet Switching ower Supply DC output wires Button cell CB Manufacturer/ trademark Shangyu Jintao Electron Co., Ltd. Shangyu Jintao Electron Co., Ltd. Shangyu Jintao Electron Co., Ltd. Type/model Technical data Standard (Edition / year) age 54 of 67 Mark(s) of conformity 1 ) JT006A AC 250V, 13A BS BSI Licence o: 1120 H05VV-F 3 x 0.75 mm² E VDE JT-ST3 AC 250V, 10A E VDE Shenzhen Kangyongda Electronics Co., Ltd. DE VAC, 10A, C14 E VDE Zhejiang LECI RS601 series 250VAC, 6(4)A E VDE Electronics Co., Ltd Min. thickness mm XIAME HUILOG AWG, 300V, UL 758 UL CABLE CO LTD 80 C, VW-1 E DOGGUA SALIT SALIT S-901- Min. 300V, 125 C, UL 224 UL CO LTD 300, SALIT VW-1 E S , SALIT S- ZHEJIAG HOGXIG ELECTRICAL CO LTD MEA WELL Enterprises Co., Ltd. HT-600 HX3960X-YYY 250VAC, 1.5A UL 94, UL 1977 ES Input: V~, 50/60Hz, 0.6A; Output: 12VDC, 2.1A L*W=105.8mm*55.1 mm, Min. thickness 0.35mm XIAME HUILOG CABLE CO LTD GUAGDOG TIAQIU ELECTROICS TECHOLOGY CO LTD SHEZHE MULTILAYER CB TECHOLOGY CO LTD AWG, 300V, 105 C, VW-1 CR V, 38mAh; Max. Abnormal Charging Current: 2.5mA; Max. Abnormal Charging Voltage: 3.5VDC IEC/E UL 94 UL 758 UL 1642 UL E TUV RH CB Report o.: ; CE Cert. o.: R UL UL E UL MH48705 MTL-M V-0, 130 C UL 796 UL E307592

55 E Report o.: R2XM (Alt.) SHEZHE UIWELL UW01 V-0, 130 C UL 796 UL CIRCUITS CO LTD E (Alt.) V-0, 130 C UL 796 UL 1) An asterisk indicates a mark which assures the agreed level of surveillance. Supplementary information: TABLE: Opto Electronic Devices Manufacturer...: -- Type...: -- Separately tested...: -- Bridging insulation...: -- External creepage distance...: -- Internal creepage distance...: -- Distance through insulation...: -- Tested under the following conditions...: -- Input...: -- Output...: -- Supplementary information: TABLE: Electrical data (in normal conditions) U (V) I (A) Irated (A) (W) Fuse # Ifuse (A) Condition/status 90V50Hz ormal operation, rated load. 90V60Hz Ditto 100V50Hz Ditto 100V60Hz Ditto 240V50Hz Ditto 240V60Hz Ditto 264V50Hz Ditto 264V60Hz Ditto Supplementary information: c) 1) TABLE: max. V, A, VA test Voltage (rated) (V) Current (rated) (A) Voltage (max.) (V) Current (max.) (A) VA (max.) (VA) supplementary information: see appended table 2.5. age 55 of 67

56 E Report o.: R2XM c) 2) TABLE: stored energy Capacitance C (µf) Voltage U (V) Energy E (J) Supplementary information: TABLE: discharge test Condition τ calculated (s) τ measured (s) t u 0V Comments supplementary information: 2.2 TABLE: evaluation of voltage limiting components in SELV circuits Component (measured between) Max. Voltage (V) (normal operation) V peak V d.c. Voltage Limiting Components Fault test performed on voltage limiting components Voltage measured (V) in SELV circuits (V peak or V d.c.) Supplementary information: see clause TABLE: limited power sources Circuit output tested: see below Measured Uoc (V) with all load circuits disconnected... : see below Conditions: Uoc (V) Isc (A) VA For lan port Meas. Limit Meas. Limit ormal operating R198 SC R194 SC T1 pin 1-24 SC C417 SC For RJ11 port 1 age 56 of 67

57 E Report o.: R2XM ormal operating F13 SC J15 pin A5-B6 SC Supplementary information: Table: working voltage measurement Location RMS voltage (V) eak voltage (V) Comments L/ to metal enclosure L to rimary circuits to secondary circuits TV-3 circuits to metal enclosure supplementary information: and TABLE: Clearance and creepage distance measurements Clearance (cl) and creepage distance (cr) at/of/between: U peak (V) U r.m.s. (V) Required cl (mm) cl (mm) Required cr (mm) cr (mm) Functional: L to Basic/supplementary: L/ to metal enclosure Internal hazardous live part to metal enclosure TV-3 circuits to metal enclosure Reinforced: rimary circuits to secondary circuits >10.0 Supplementary information: the above data were not considered for the power supply board, the clearance and creepage distance of primary circuit, and primary circuit to secondary circuit for power board had been evaluated in approved switching power supplies TABLE: Distance through insulation measurements Distance through insulation (DTI) at/of: U peak (V) U rms (V) Test voltage (V) Required DTI (mm) DTI (mm) Supplementary information: age 57 of 67

58 E Report o.: R2XM TABLE: Batteries The tests of are applicable only when appropriate battery data is not available Yes - Is it possible to install the battery in a reverse polarity position? o - Max. current during normal condition Max. current during fault condition (D32 SC) Test results: on-rechargeable batteries Meas. Current (ma) Discharging Manuf. Specs. (ma) Unintentional charging (ma) Meas. Current (ma) Rechargeable batteries Charging Discharging Reversed charging Manuf. Specs. (ma) Meas. Current (ma) Manuf. Specs. (ma) Meas. Current (ma) Manuf. Specs. (ma) Chemical leaks o chemical leaks affecting required insulation. - Explosion of the battery o explosion. - Emission of flame or expulsion of molten metal o emission of flame or expulsion of molten metal. - Electric strength tests of equipment after completion of tests Supplementary information: 1. SC=short circuited. Verdict TABLE: Batteries Battery category...: Button cell Manufacturer...: See appended table Type / model...: See appended table Voltage...: See appended table Capacity...: See appended table Tested and Certified by (incl. Ref. o.)...: See appended table Circuit protection diagram: See below age 58 of 67

59 E Report o.: R2XM MARKIGS AD ISTRUCTIOS (1.7.13) Location of replaceable battery Language(s).: Close to the battery.: In the servicing instructions... : In the operating instructions..: Inside of enclosure English Yes Yes Yes 4.5 TABLE: Thermal requirements Supply voltage (V)... : 90V60Hz 264V50Hz Ambient T min ( C)...: 24.8 Adjust to 24.8 Adjust to Ambient T max ( C)...: 24.9 Tma= Tma=40.0 Maximum measured temperature T of part/at:: T ( C) Allowed Tmax ( C) Appliance inlet Metal enclosure top Metal enclosure bottom Internal AC input wire Internal AC connector Ref. Internal DC output wire CB near D CB near U Supplementary information: Temperature T of winding: t 1 ( C) R 1 (Ω) t 2 ( C) R 2 (Ω) T ( C) Allowed Tmax ( C) age 59 of 67 Insulation class Supplementary information:

60 E Report o.: R2XM TABLE: Ball pressure test of thermoplastic parts art Allowed impression diameter (mm)... : 2 mm Test temperature ( C) Impression diameter (mm) Internal AC connector Supplementary information: 4.7 TABLE: Resistance to fire art Manufacturer of material Type of material Thickness (mm) Flammability class Evidence Supplementary information: see appended table TABLE: touch current measurement Measured between: Measured (ma) Limit (ma) Comments/conditions L/ to metal enclosure (E) Switch e opened L/ to secondary terminals Switch e closed supplementary information: 1. Test voltage: 264V, 60Hz 5.2 TABLE: Electric strength tests, impulse tests and voltage surge tests Test voltage applied between: Voltage shape (AC, DC, impulse, surge) Test voltage (V) Breakdown Yes / o L to (fuse opened) AC 1500 o L/ to metal enclosure AC 1500 o L/ to secondary terminals AC 3000 o TV-3 circuits to metal enclosure AC 1000 o TV-3 circuits to SELV circuits AC 1000 o Supplementary information: 5.3 TABLE: Fault condition tests Ambient temperature ( C)... : ower source for EUT: Manufacturer, model/type, output rating... : See page 2 age 60 of 67

61 E Report o.: R2XM Component o. One side openings Fault Supply voltage (V) Test time Fuse # Fuse current (A) Blocked 264VAC 3 hrs FS1 C428 SC 264VAC 15 mins FS1 U43 pin 8-6 SC 264VAC 15 mins FS1 U28 pin 7-6 SC 264VAC 15 mins FS1 D3 SC 264VAC 15 mins FS1 R314 SC 264VAC 15 mins FS Supplementary information: 1. SC=Short circuited. 2. All above tests were also performed on 90VAC and got the same results. Observation Unit working normally, no fire or molten metal occured, no hazard. T1 coil: 59.8 C; Ambient: 24.5 C. Unit shut down immediately, no fire or molten metal occured, no hazard. Unit shut down immediately, no fire or molten metal occured, no hazard. Unit shut down immediately, no fire or molten metal occured, no hazard. Unit working normally, no fire or molten metal occured, no hazard. Unit working normally, no fire or molten metal occured, no hazard. C.2 TABLE: transformers Loc. Tested insulation Working voltage peak / V (2.10.2) Working voltage rms / V (2.10.2) Required electric strength (5.2) Required clearance / mm (2.10.3) Required creepage distance / mm (2.10.4) Loc. Tested insulation Test voltage/ V Measured clearance / mm Measured creepage dist./ mm supplementary information: -- Required distance thr. insul. (2.10.5) Measured distance thr. insul. / mm; number of layers C.2 TABLE: transformers age 61 of 67

62 Report o.: R2XM Appendix A - EUT HOTOS hoto 1 overall view hoto 2 general view age 62 of 67

63 Report o.: R2XM hoto 3 general view hoto 4 internal view age 63 of 67

64 Report o.: R2XM hoto 5 internal view hoto 6 internal view age 64 of 67

65 Report o.: R2XM hoto 7 power board top view hoto 8 power board bottom view age 65 of 67

66 Report o.: R2XM hoto 9 main board top view hoto 10 main board bottom view age 66 of 67

TEST REPORT. Building 24 (floors1,3,4,5) and 28 (floors1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Standards used:

TEST REPORT. Building 24 (floors1,3,4,5) and 28 (floors1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Standards used: TEST REPORT To: Address: TP-LINK TECHNOLOGIES CO., LTD. Building 24 (floors1,3,4,5) and 28 (floors1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Factory name: TP-LINK TECHNOLOGIES

More information

TEST REPORT. Reference No.:A Report No.:LVDA Page:2 of 34 Date:Feb. 20, 2003

TEST REPORT. Reference No.:A Report No.:LVDA Page:2 of 34 Date:Feb. 20, 2003 age:2 of 34 Type of test object... : Wireless 11b Card Bus Trademark... : MSI Model and/or type reference... : MS-6802 Manufacturer... : MICRO-STAR IT L CO., LTD. Rating(s)... : DC 3.3V, 400 ma articulars:

More information

TEST REPORT EN Safety of information technology equipment Part 1-General requirements

TEST REPORT EN Safety of information technology equipment Part 1-General requirements TEST REORT E 60950-1 Safety of information technology equipment art 1-General requirements Report reference o... : R2XM180306052-A1-03 Compiled by (+ signature)... : Test Engineer: Acan Liang Approved

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of SHENZHEN MUST POWER LIMITED. Inverter. Model(s): EP301012E-1000W, EP301512E-1500W, EP302012E-2000W

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of SHENZHEN MUST POWER LIMITED. Inverter. Model(s): EP301012E-1000W, EP301512E-1500W, EP302012E-2000W SHEZHE EMTEK CO., LTD. REORT O.: ES101214112S ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of SHEZHE MUST OWER LIMITED Inverter Model(s): E301012E-1000W, E301512E-1500W, E302012E-2000W repared For : SHEZHE

More information

TEST REPORT. Date: September 27, 2016 Date: September 27, 2016

TEST REPORT. Date: September 27, 2016 Date: September 27, 2016 TEST REORT To: Address: T-LINK TECHNOLOGIES CO., LTD. Building 24 (floors1,3,4,5) and 28 (floors1-4) Central Science and Technology ark, Shennan Rd, Nanshan, Shenzhen, China Factory name: T-LINK TECHNOLOGIES

More information

Shenzhen BST Technology Co., Ltd. Report No.: BST SR ITUNER NETWORKS CORPORATION

Shenzhen BST Technology Co., Ltd. Report No.: BST SR ITUNER NETWORKS CORPORATION Report o.: BST180610402210SR ITUER ETWORKS CORPORATIO LVD REPORT Prepared For: ITUER ETWORKS CORPORATIO 47801 Fremont Blvd. Fremont, CA. 94538 Product ame: OPEUPS Trade ame: OPEUPS Model: OPEUPS Prepared

More information

Shenzhen BST Technology Co., Ltd. Report No.: BST Y-1SR-2 XIAMEN RGBLINK SCIENCE & TECHNOLOGY CO., LTD. TEST REPORT

Shenzhen BST Technology Co., Ltd. Report No.: BST Y-1SR-2 XIAMEN RGBLINK SCIENCE & TECHNOLOGY CO., LTD. TEST REPORT Report o.: BST1703503790002-1Y-1SR-2 XIAME RGBLIK SCIECE & TECHOLOGY CO., LTD. TEST REORT repared For: XIAME RGBLIK SCIECE & TECHOLOGY CO., LTD. S603-604 Weiye building Torch Hi-Tech Industrial Development

More information

TEST REPORT EN Information technology equipment Safety Part 1: General requirements

TEST REPORT EN Information technology equipment Safety Part 1: General requirements age 1 of 56 TEST REORT EN 60950-1 Information technology equipment Safety art 1: General requirements Report Reference No... : Tested by (name + signature)...: Compiled by (name+ signature)...: Approved

More information

LOW VOLTAGE DIRECTIVE TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN : 2006+A11:2009+A1:2010+A12:2011+A2:2013

LOW VOLTAGE DIRECTIVE TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN : 2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 50 Report No.: L482629L329 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Report Reference No....

More information

TEST REPORT. To: Legrand Limoges To: - Attn: OLIVIER CHABROUX Attn: - Address: 128 Av du Marechal De Lattre

TEST REPORT. To: Legrand Limoges To: - Attn: OLIVIER CHABROUX Attn: - Address: 128 Av du Marechal De Lattre TEST REORT To: Legrand Limoges To: - Attn: OLIVIER CHABROUX Attn: - Address: 128 Av du Marechal De Lattre Address: - De Tassigny 87045 LIMOGES Cedex France Fax: -- Fax: - E-mail: -- E-mail: - This document

More information

SAFETY TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN :2006+A11:2009+A1:2010+A12:2011+A2:2013

SAFETY TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN :2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 50 Report No.: L813120L132 SAFETY TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Report Reference No.... : L813120L132

More information

TEST REPORT IEC :2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC :2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT :2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Number.... : 16C2012S Date

More information

CHINA WORLD CONNECTION(HK) CO.,LTD CHINA WORLD CONNECTION(HK) CO.,LTD

CHINA WORLD CONNECTION(HK) CO.,LTD CHINA WORLD CONNECTION(HK) CO.,LTD CHINA WORLD CONNECTION(HK) CO.,LTD LVD REORT repared For : CHINA WORLD CONNECTION(HK) CO.,LTD Room 608, Ban Tian Group Business Center Building, Lipu Street,West Changfa Road, Bantian, Longgang District.,Shenzhen

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number... : ES150530373S Date of issue... : June 26, 2015 Total number of pages.: 79 CB Testing Laboratory...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number... : ES150318170S-1 Date of issue... : April 16, 2015 Total number of pages.: 75 CB Testing Laboratory...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : T221-0052/16 Date of issue... : 2016-07-14

More information

:2006+A11:2009+A1:2010+A12:2011+A2:2013

:2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 54 Report No.:L612818L022 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Information technology

More information

CERTIFICATE CERTIFY THAT:

CERTIFICATE CERTIFY THAT: SPORTON LAB. Certificate No: L442480L129 CERTIFICATE EQUIPMENT: Embedded Bluetooth AT Module MODEL NO. : TRBLU24-00100, TRBLU24-00100-NA, BISMS02BI, BISMS02BI-NA APPLICANT: Laird Technologies 11160 Thompson

More information

EN :2006+A11:2009+A1:2010+A12:2011+A2:2013. Jams Xu Checked By

EN :2006+A11:2009+A1:2010+A12:2011+A2:2013. Jams Xu Checked By SAFETY REORT Report o.: 17020741-CE-S Applicant roduct ame Model o. Test Standard SAHAB TECHOLOGY EXASIO MODULE XT-23EX E 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Test Date 2016-07-27 to 2016-08-08

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Report Reference No.... : age 1 of 100 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements 160918071GZU-001 Date of

More information

SABLE-X AND SABLE-X-R2 DEVELOPMENT BOARD SAFETY CHECKLIST TEST REPORT

SABLE-X AND SABLE-X-R2 DEVELOPMENT BOARD SAFETY CHECKLIST TEST REPORT SABLE-X AND SABLE-X-R2 DEVELOPMENT BOARD SAFETY CHECKLIST TEST REPORT EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 + A2:2013 Last updated May 22, 2017 330-0172-R3.0 Copyright 2015-2017 LSR Page 1 of 68

More information

Page 3 of 49 Report Ref. No.:

Page 3 of 49 Report Ref. No.: age 3 of 49 Report Ref. No.: 211-300485-000 Copy of marking plate The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these

More information

SAFETY TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN : 2006+A11:2009+A1:2010+A12:2011+A2:2013

SAFETY TEST REPORT IEC :2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN : 2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 50 Report No.: L642913L282 SAFETY TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Report Reference No.... : L642913L282

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3 1 Report No.: BL-SZ1680316-102 Revision History Version Issue Date Revision Content Rev. 01 Oct. 25, 2016 Initial Issue Rev. 02 Rev. 03 Rev. 04 Mar. 08, 2017 Mar. 17, 2017 Mar. 23, 2017 Evaluation of TNV

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No....

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : 1772059S.50 Date of issue... : 2017-07-20 Total number

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of www.nemko.com TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : 312253 Date of issue... : 2016-07-11

More information

Page 2 of 69 VDE Report No.: / DC - DC Converter for building in. TDK Innoveta Inc. iba - Series (see model matrix appendix 1)

Page 2 of 69 VDE Report No.: / DC - DC Converter for building in. TDK Innoveta Inc. iba - Series (see model matrix appendix 1) Page 2 of 69 VDE Report No.: 2520400-3336-0009/132550 Test item description... : Trade Mark...: Manufacturer...: Model/Type reference...: Serial Number..: Ratings...: Input: Output: Ambient: DC - DC Converter

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number.... : LCS1612152124S Date of issue... : 2016-12-23 Total number of pages... : 37 Applicant s name... : Address...

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2012-12-21 Page 1 of 68 Report Reference # NC8736-A1-IT-5 Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part 1: General requirements NC8736-A1-IT-5

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Report Number....: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements SHES130700266901 Date of issue...: 2013-09-04

More information

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS SAUDI STANDARD NO. SASO IEC 60669-2-2: 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS Part 2-2: Particular requirements Electromagnetic remote-control switches (RCS) SAUDI ARABIAN

More information

APPLICATION FOR R&TTE DIRECTIVE On Behalf of. : TBS Avionics Co. Limited. Video Transmitter Model: TBS GREENHORN

APPLICATION FOR R&TTE DIRECTIVE On Behalf of. : TBS Avionics Co. Limited. Video Transmitter Model: TBS GREENHORN Page 1 of 49 Report o. R011412646S APPLICATIO FOR R&TTE DIRECTIVE On Behalf of TBS Avionics Co. Limited Video Transmitter Model: TBS GREEHOR Prepared For : TBS Avionics Co. Limited Room G, 4/F, Winner

More information

Standard ECMA-287 Technical Report EACEM TR-027

Standard ECMA-287 Technical Report EACEM TR-027 EACEM Safety of electronic equipment Standard ECMA-287 Technical Report EACEM TR-027 ECMA Standardizing Information and Communication Systems Phone: +41 22 849.60.00 - Fax: +41 22 849.60.01 - www.ecma.ch

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2012-12-11 Page 1 of 52 Report Reference # E211395-A3-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT Information technology equipment - Safety - Part

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Page 1 of 69 Test Report issued under the responsibility: TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number....: 140314044GZU-009 Date of issue...: Jan. 9,

More information

HAND-HELD MULTIMETERS

HAND-HELD MULTIMETERS Test Report issued under the responsibility of: TEST REORT IEC 61010-1, and IEC 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use. art 1: General requirements,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number.... : 1510061STO-001 Date of issue... : 29 October 2015 Total

More information

TEST REPORT. EN Information technology equipment Safety Part 1: General requirements EMC-CE-S1082. Jae-Kyu, Lee. EMC Compliance Ltd.

TEST REPORT. EN Information technology equipment Safety Part 1: General requirements EMC-CE-S1082. Jae-Kyu, Lee. EMC Compliance Ltd. TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : Tested by (printed name and signature)... : Approved by (printed name and signature)... : EMC-CE-S1082

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT Information technology equipment Safety Part 1: General requirements Report

More information

page 2 of 86 Report reference No:

page 2 of 86 Report reference No: articulars: test item vs. test requirements 3. Classification 3.1. Utilization category: (A or B)... : A 3.2. Interruption medium: (air, vacuum, gas Break)... : Air 3.3. Design: (open construction, moulded

More information

TEST REPORT IEC , IEC

TEST REPORT IEC , IEC Test Report issued under the responsibility of: TEST REORT IEC 61010-1, IEC 61010-2-032 and IEC 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use. art

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2013-01-16 Page 1 of 51 Report Reference # E238623-A131-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB 1 Science ark Drive, 118221 Singapore TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... :

More information

TEST REPORT EN Information technology equipment Safety Part 1: General requirements

TEST REPORT EN Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT EN 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : SA1703052L 01001 Date of issue... : 2017-03-21

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2013-01-08 Page 1 of 52 Report Reference # E238623-A89-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC and/or EN , First Edition Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC and/or EN , First Edition Information technology equipment Safety Part 1: General requirements Report o: 02173691.003 age 1 of 107 TEST REORT IEC 60950-1 and/or E 60950-1, First Edition Information technology equipment Safety art 1: General requirements Report reference o.... : 02173691.003 Tested

More information

Prüfbericht / Test Report Nr. / No (Edition 2)

Prüfbericht / Test Report Nr. / No (Edition 2) May 31, 2012 age 1 of 74 rüfbericht / Test Report Nr. / No. 11383-04388-2 (Edition 2) Auftraggeber Applicant Geräteart Type of equipment Typenbezeichnung Type designation Auftragsnummer / Order No. rüfgrundlage

More information

EC Declaration of Conformity

EC Declaration of Conformity EC Declaration of Conformity EC Declaration of Conformity According to Low Voltage Directive 2006/95/EC Report No: Type of equipment: Model Name: Applicant: Address: Manufacturer: Address: Test Standards:

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2013-01-08 Page 1 of 51 Report Reference # E238623-A110-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS CONTENTS CONTENTS CONTENTS 1. SAFETY INFORMATION...1 1.1 Preliminary...1 1.2 Dos and don ts...2 1.3 Symbols...3 1.4 Precautions...4 2. DESCRIPTION...5 2.1 Names of parts...6 2.2 Switches, buttons and input

More information

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60065 Audio, video and similar electronic apparatus - Safety requirements Report Number... : 246847 Date of issue... : October

More information

TEST REPORT EN Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements

TEST REPORT EN Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements age 1 of 81 TEST REORT EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General requirements Report Number.... : S12WR-009 Date of issue... :

More information

Test Report THREE PHASE FULLY AUTOMATIC AC VOLTAGE REGULATOR

Test Report THREE PHASE FULLY AUTOMATIC AC VOLTAGE REGULATOR Test Report Applicant: GUANGDONG EAST OWER CO., LTD roduct: THREE HASE FULLY AUTOMATIC AC VOLTAGE REGULATOR Brand Name: EAST Model No: ZTY-30KVA repared by: Most Technology Service Co., Limited The safety

More information

Report Number....: Test Report issued under the responsibility of Page 1 of 104 TEST REPORT IEC Information technology equipment Safety Part 1

Report Number....: Test Report issued under the responsibility of Page 1 of 104 TEST REPORT IEC Information technology equipment Safety Part 1 Report Number....: Test Report issued under the responsibility of age 1 of 104 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements HK12010466-1 Date of issue...:

More information

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD. (INDIA) VT. LTD. Clause Requirement Test Results Remarks Verdict 5 Marking and documentation 5.1 Marking 5.1.1 General Markings shall be visible from the exterior, or be visible after removing a cover

More information

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 32 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements Section Thirteen d.c. or a.c. supplied electronic

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications Report o.:rdg180408050-03 TEST REORT E 62031 LED modules for general lighting Safety specifications Report Reference o.... : RDG180408050-03 Compiled by (+ signature)... : Approved by (+ signature)...

More information

Report. radio. : Mobile : TYT MODEL NAME CLIENT : V1.0 CAUTION:

Report. radio. : Mobile : TYT MODEL NAME CLIENT : V1.0 CAUTION: Report o.: AGC01039140302ES01 age 1 of 51 Safety Test Report Report o.: AGC01039140302ES01 TEST AME RODUCT DESIGATIO BRAD AME MODEL AME CLIET DATE OF ISSUE STADARD(S) REORT VERSIO : 1999/ /5/EC R&TTE Directive

More information

HI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date

HI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date Last Amended on - Page 1 of 14 I. AUDIO EQUIPMENT 1. Audio-Video and Similar Electronics Apparatus Safety Requirement Marking & Instructions Laser Radiation (Products Marked Class I only) Heating under

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT Information technology equipment Safety art 1: General requirements Report Number....

More information

CB Testing Laboratory...:EZÚ Address...:Pod Lisem Praha71-Trója Testing location/ procedure...: CBTL RMT SMT WMT TMP IEC60947_2C

CB Testing Laboratory...:EZÚ Address...:Pod Lisem Praha71-Trója Testing location/ procedure...: CBTL RMT SMT WMT TMP IEC60947_2C age 1 of 109 Report No.600332-04/01 TEST REORT Low-voltage switchgear and controlgear art 2: Circuit - breakers Report Reference No....: 600332-04/01 Tested by (name+signature)...:... Witnessed by (name+signature)...:...

More information

Test Report. The safety testing has been performed on the submitted samples and found in compliance with the council LVD directive 2006/95/EC.

Test Report. The safety testing has been performed on the submitted samples and found in compliance with the council LVD directive 2006/95/EC. Test Report Applicant: GUANGDONG EAST OWER CO., LTD roduct: FULLY AUTOMATIC AC VOLTAGE REGULATOR Brand Name: EAST Model No: ZTY-20KVA, ZTY-10KVA, ZTY-15KVA repared by: Most Technology Service Co., Limited

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

400Amp True RMS AC Clamp Meter + NCV

400Amp True RMS AC Clamp Meter + NCV User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

ATTESTATION OF CONFORMITY

ATTESTATION OF CONFORMITY ATTESTATION OF CONFORMITY According to Low Voltage Directive 2006/95/EC No. Product KBW-2014-SI-010 NETWORK CAMERA Model /Trade ref. SNZ-6320 Holder of Certificate Manufacturer Trade Mark SAMSUNG TECHWIN

More information

Summary of testing: The product has been tested according to standard IEC : 2010 & IEC : 2011.

Summary of testing: The product has been tested according to standard IEC : 2010 & IEC : 2011. Summary of testing: The product has been tested according to standard IEC 62109-1: 2010 & IEC 62109-2: 2011. List of Attachments (including a total number of pages in each attachment): This test report

More information

Prepared by Mick Maytum

Prepared by Mick Maytum IEC Technical Committee 109: Standards on insulation co-ordination for low-voltage equipment Warning Prepared by Mick Maytum mjmaytum@gmail.com The document content is of a general nature only and is not

More information

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements Test Report issued under the responsibility of: TEST REORT IEC 60065 Audio, video and similar electronic apparatus - Safety requirements Report Number.... : 17706907 001 Date of issue... : See cover page

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : OFF-4787534005-A-1 Date of issue... : 2016-08-29

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2007-10-24 Page 1 of 6 Report Reference # E210157-A29-UL-1 SPECIFIC TECHNICAL CRITERIA UL 60950-1, First Edition Information technology equipment - Safety- Part 1: General Requirements Report

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207721-AS3-1 CB/DE1-55140 Date of issue...

More information

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 31 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements Section Thirteen d.c. or a.c. supplied electronic

More information

TEST REPORT EN Safety of information technology equipment Part 1-General requirements Report reference No.... : RKS Compiled by (+

TEST REPORT EN Safety of information technology equipment Part 1-General requirements Report reference No.... : RKS Compiled by (+ TEST REPORT Safety of information technology equipment Part 1-General requirements Report reference o.... : Compiled by (+ signature)... : Test Engineer: Tiller Chen Approved by (+ signature)... : Date

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

TEST REPORT IEC Adjustable speed electrical power drive systems Part 5-1: Safety requirements Electrical, thermal and energy

TEST REPORT IEC Adjustable speed electrical power drive systems Part 5-1: Safety requirements Electrical, thermal and energy Test Report issued under the responsibility of: TEST REPORT Adjustable speed electrical power drive systems Part 5-1: Safety requirements Electrical, thermal and energy Report Reference No.... : 4787846262

More information

MS2109A AC/DC Clamp Meter. User Manual. Contents

MS2109A AC/DC Clamp Meter. User Manual. Contents MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description

More information

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product

More information

TEST REPORT DIN V VDE V :2006 Automatic disconnecting device

TEST REPORT DIN V VDE V :2006 Automatic disconnecting device age 1 of 23 TEST REORT Automatic disconnecting device Report Reference No...: GZ10080033-1 Date of issue...: August 18, 2010 Total number of pages... 23 pages Testing Laboratory...: Address...: Tested

More information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL 600A AC Clamp Meter + NCV Model MA610 USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 210282-CI3-2 CB DE1-56459 Date of issue...

More information

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011 NATIONAL RULES FOR ELECTRICAL INSTALLATIONS Fourth Edition ET 101:2008 Extracts from Amendment No.1:2011 22 June 2011 Page vi: Insert after 1 st Paragraph: Section 710: Medical Locations was prepared by

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

ITC ENGINEERING SERVICES, INC.

ITC ENGINEERING SERVICES, INC. Test Report issued under the responsibility of: ITC ENGINEERING SERVICES, INC. IEC 61010-1:2010, Safety Requirements for Electrical Equipment For Measurement, Control and Laboratory Use art 1 General Requirements

More information

MS2030 CAT III 600 V A V AUTO RS232

MS2030 CAT III 600 V A V AUTO RS232 MS2030 AC Digital Clamp Meter User s Manual CAT III 600 V AUTO RS232 A V CONTENTS 1.Introduction...1 2.Safety Information...1 2.1 Precautions...1 2.2 Safety Symbols...3 3. Description...4 3.1 Front Panel...4

More information

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n. MS8265 DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD ON/OFF LIGHT 1000V CAT II 600V CAT III MS8265 200K 2M 20M 20K 200M KHz 2K 20 200 2 20 200μ 200 20μ 750 2μ 1000 200n F 20n 10A 2m 200m 10 10

More information

EN Information technology equipment Safety Part 1: General requirements

EN Information technology equipment Safety Part 1: General requirements EN 61010-1 Information technology equipment Safety Part 1: General requirements Report Number....: 14PP083-01_1 Date of issue...: 2013-09-05 Total number of pages... 25 Tested by...: Thomas Rogg (printed

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

79/26 Series III Multimeter

79/26 Series III Multimeter 79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position

More information

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC LVD TEST REPORT

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC LVD TEST REPORT CETRE OF TESTIG SERVICE ITERATIOAL OERATE ACCORDIG TO ISO/IEC 17025 LVD TEST REORT TEST REORT UMBER : CGZ3141231-04410-L CTS (ingbo) Testing Service Technology Co., Ltd. Fl.2 South Huoju Building, o.181

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to

More information

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS TR550004 TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS TR NO. 174001 EDITION 2.1 September 3 rd, 2018 Nippon Telegraph and

More information

EC Declaration of Conformity

EC Declaration of Conformity EC Declaration of Conformity EC Declaration of Conformity According to Low Voltage Directive 2006/95/EC Report No: Type of equipment: Model Name: Applicant: Address: Manufacturer: Address: EMC-CE-S1244

More information

DE Total. American Inc. IEC Test Report Form. If this. and appended to General disclaimer: the NCB, VDE File. No VDE File.

DE Total. American Inc. IEC Test Report Form. If this. and appended to General disclaimer: the NCB, VDE File. No VDE File. 1Fdar Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: 215009-CI3-1 Date of issue...: 2015-07-31

More information

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV. MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM

More information