Network Analyzer Basics
|
|
- Clara Hines
- 6 years ago
- Views:
Transcription
1
2 Network Analysis is NOT. Router Bridge Repeater Hub Your IEEE X.25 ISDN switched-packet data stream is running at 147 MBPS with -9 a BER of X 10...
3 What Types of Devices are Tested? Integration High Low Duplexers Diplexers Filters Couplers Bridges Splitters, dividers Combiners Isolators Circulators Attenuators Adapters Opens, shorts, loads Delay lines Cables Transmission lines Waveguide Resonators Dielectrics R, L, C's Antennas Switches Multiplexers Mixers Samplers Multipliers Diodes RFICs MMICs T/R modules Transceivers Receivers Tuners Converters VCAs Amplifiers VCOs VTFs Oscillators Modulators VCAtten s Transistors Passive Device type Active
4 Device Test Measurement Model Complex Response tool Simpl e Ded. Testers VSA SA VNA TG/SA SNA NF Mtr. Imped. An. Param. An. Power Mtr. Det/Scope Harm. Dist. LO stability Image Rej. I-V LCR/Z Gain/Flat. Compr'n Phase/GD AM-PM Isolation Rtn Ls/VSWR Impedance S-parameters Absol. Power Gain/Flatness NF NF RFIC test Intermodulation Distortion Measurement plane DC CW Swept Swept Noise 2-tone Multi- Complex Pulsed- Protocol freq power tone modulation RF Simple Complex Stimulus type BER EVM ACP Regrowth Constell. Eye Full call sequence Pulsed S-parm. Pulse profiling
5 Lightwave Analogy to RF Energy Incident Transmitted Reflected Lightwave DUT RF
6 Why Do We Need to Test Components? Verify specifications of building blocks for more complex RF systems Ensure distortionless transmission of communications signals linear: constant amplitude, linear phase / constant group delay nonlinear: harmonics, intermodulation, compression, AMto-PM conversion Ensure good match when absorbing power (e.g., an antenna) KPWR FM 97
7 The Need for Both Magnitude and Phase 1. Complete characterization of linear networks 2. Complex impedance needed to design matching circuits S 21 S 11 S 22 S Time-domain characterization Mag 3. Complex values needed for device modeling Base High-frequency transistor model Emitter Collector Time 5. Vector-error correction Error Measured Actual
8 Agenda What measurements do we make? Transmission-line basics Reflection and transmission parameters S-parameter definition Network analyzer hardware Signal separation devices Detection types Dynamic range T/R versus S-parameter test sets Error models and calibration Types of measurement error One- and two-port models Error-correction choices Basic uncertainty calculations Example measurements Appendix
9 Transmission Line Basics + - I Low frequencies wavelengths >> wire length current (I) travels down wires easily for efficient power transmission measured voltage and current not dependent on position along wire High frequencies wavelength or << length of transmission medium need transmission lines for efficient power transmission matching to characteristic impedance (Zo) is very important for low reflection and maximum power transfer measured envelope voltage dependent on
10 Transmission line Zo Zo determines relationship between voltage and current waves Zo is a function of physical dimensions and ε r Zo is usually a real impedance (e.g. 50 or 75 ohms) Twisted-pair Waveguide attenuation is lowest at 77 ohms a b Coaxial w2 Coplanar w1 εr h w Microstrip h normalized values ohm standard power handling capacity peaks at 30 ohms characteristic impedance for coaxial airlines (ohms)
11 Power Transfer Efficiency RS Load Power (normalized) RL / RS RL For complex impedances, maximum power transfer occurs when ZL = ZS* (conjugate match) Rs +jx -jx RL Maximum power is transferred when RL = RS
12 Transmission Line Terminated with Zo Zs = Zo Zo = characteristic impedance of transmission line Zo V inc Vrefl = 0! (all the incident power is absorbed in the load) For reflection, a transmission line terminated in Zo behaves like an infinitely long transmission line
13 Transmission Line Terminated with Short, Open Zs = Zo V inc Vrefl In-phase (0 o ) for open, out-of-phase (180 o ) for short For reflection, a transmission line terminated in a short or open reflects all power back to source
14 Transmission Line Terminated with 25 Ω Zs = Zo ZL = 25 Ω V inc Vrefl Standing wave pattern does not go to zero as with short or open
15 High-Frequency Device Characterization Incident R Reflected A REFLECTION Transmitted B TRANSMISSION Reflected Incident = A R Transmitted Incident = B R SWR S-Parameters S 11, S 22 Reflection Coefficient Γ, ρ Return Loss Impedance, Admittance R+jX, G+jB Gain / Loss S-Parameters S 21, S 12 Transmission Coefficient Τ,τ Insertion Phase Group Delay
16 Reflection Parameters Reflection Coefficient Γ Return loss = -20 log(ρ), = V reflected V incident = ρ Φ ρ = Γ = Z L Z O Z L + ZO Emax Emin Voltage Standing Wave Ratio VSWR = Emax Emin = 1 + ρ 1 - ρ No reflection (ZL = Zo) Full reflection (ZL = open, short) 0 ρ 1 db RL 0 db 1 VSWR
17 Smith Chart Review. +jx Polar plane 90 o R o o -jx Rectilinear impedance plane Smith Chart maps rectilinear impedance plane onto polar plane 0 Z = 0 L Γ Z = Zo L Γ = 0-90 o (short) Z = L = 1 ±180 O Smith chart Constant X Γ Constant R = 1 0 O (open)
18 Transmission Parameters V Incident DUT V Transmitted Transmission Coefficient = Τ = V Transmitted V Incident = τ φ V Trans Insertion Loss (db) = - 20 Log V Inc = - 20 log τ V Trans Gain (db) = 20 Log V Inc = 20 log τ
19 Linear Versus Nonlinear Behavior Sin 360 o * f * t A t o A A * Sin 360 o * f (t - t o ) Time phase shift = to * 360 o * f Linear behavior: input and output frequencies are the same (no additional frequencies created) output frequency only undergoes magnitude and phase change Time f 1 Frequency Input DUT Output f 1 Frequency f 1 Nonlinear behavior: output frequency may undergo frequency shift (e.g. with mixers) additional frequencies created (harmonics, Frequency intermodulation) Time
20 Criteria for Distortionless Transmission Linear Networks Constant amplitude over bandwidth of interest Linear phase over bandwidth of interest Magnitude Phase Frequency Frequency
21 Magnitude Variation with Frequency F(t) = sin wt + 1/3 sin 3wt + 1/5 sin 5wt Time Time Linear Network Magnitude Frequency Frequency Frequency
22 Phase Variation with Frequency F(t) = sin wt + 1 /3 sin 3wt + 1 /5 sin 5wt Linear Network Time Time Magnitude Frequency Frequency Frequency -360
23 Deviation from Linear Phase Use electrical delay to remove linear portion of phase response o Phase 45 /Div RF filter response Linear electrical length added (Electrical delay function) + yields Deviation from linear phase o Phase 1 /Div Frequency Frequency Frequency Low resolution High resolution
24 Group Delay Phaseφ Δφ Frequency Δω ω t g t o Group delay ripple Average delay Group Delay (t ) g = d φ d ω = 1 φ ω φ in radians in radians/sec in degrees * d φ 360 o d f f in Hertz (ω = 2 π f) Frequency group-delay ripple indicates phase distortion average delay indicates electrical length of DUT aperture of measurement is very important
25 Why Measure Group Delay? Phase Phase d φ d ω f d φ d ω f Group Delay Group Delay f Same p-p phase ripple can result in different group delay f
26 Characterizing Unknown Devices Using parameters (H, Y, Z, S) to characterize devices: gives linear behavioral model of our device measure parameters (e.g. voltage and current) versus frequency under various source and load conditions (e.g. short and open circuits) compute device parameters from measured data predict H-parameters circuit performance Y-parameters under any source Z-parameters and load conditions V1 = h11i1 + h12v2 I1 = y11v1 + y12v2 V1 = z11i1 + z12i2 I2 = h21i1 + h22v2 I2 = y21v1 + y22v2 V2 = z21i1 + z22i2 h11 = V1 I1 V2=0 h12 = V1 V2 I1=0 (requires short circuit) (requires open circuit)
27 Why Use S-Parameters? relatively easy to obtain at high frequencies measure voltage traveling waves with a vector network analyzer don't need shorts/opens which can cause active devices to oscillate or self-destruct relate to familiar measurements (gain, loss, reflection coefficient...) can cascade S-parameters of multiple devices to predict system performance can compute H, Y, or Z parameters from S-parameters if desired can easily import and Incident S21 use S-parameter Transmitted files in our electronicsimulation tools S11 a1 b2 b1 Reflected Transmitted DUT Port 1 Port 2 S12 b1 =S11a 1 + S 12 a2 b2 = S21 a 1 + S22 a2 S22 Reflected a2 Incident
28 Measuring S-Parameters Incident S 21 Transmitted Forward b 1 a 1 b 2 Z 0 S 11 Reflected DUT a 2 = 0 Load S 11 = S 21 Reflected Incident = Transmitted Incident = b 1 a 1 a 2 = 0 = b 2 a 1 a 2 = 0 S 22 = S 12 Reflected Incident = Transmitted Incident = b 2 a 2 a 1 = 0 = b 1 a 2 a 1 = 0 Z 0 Load a 1 = 0 b 1 DUT Transmitted S 12 S 22 Reflected Incident b 2 a 2 Reverse
29 Equating S-Parameters with Common Measurement Terms S11 = forward reflection coefficient (input match) S22 = reverse reflection coefficient (output match) S21 = forward transmission coefficient (gain or loss) S12 = reverse transmission coefficient (isolation) Remember, S-parameters are inherently complex, linear quantities -- however, we often express them in a log-magnitude format
30 Criteria for Distortionless Transmission Nonlinear Networks Saturation, crossover, intermodulation, and other nonlinear effects can cause signal distortion Effect on system depends on amount and type of distortion and system architecture Time Time Frequency Frequency
31 SPECTRUM ANALYZER 9 khz GHz Measuring Nonlinear Behavior Most common measurements: using a network analyzer and power sweeps gain compression AM to PM conversion using a spectrum analyzer + source(s) harmonics, particularly second and third intermodulation products resulting from two or more RF carriers LPF DUT 8563A RL 0 dbm ATTEN 10 db 10 db / DIV LPF CENTER MHz SPAN khz RB 30 Hz VB 30 Hz ST 20 sec
32 . What is the Difference Between Network and Spectrum Analyzers? 8563A SPECTRUM ANALYZER 9 khz GHz Amplitude Ratio Measures known signal Amplitude Measures unknown signals Frequency Network analyzers: measure components, devices, circuits, sub-assemblies contain source and receiver display ratioed amplitude and phase (frequency or power sweeps) Network offer Analyzer advanced Basics error correction Frequency Spectrum analyzers: measure signal amplitude characteristics carrier level, sidebands, harmonics...) can demodulate (& measure) complex signals are receivers only (single channel) can be used for scalar component test (no phase) with tracking gen or ext
33 Agenda What measurements do we make? Network analyzer hardware Error models and calibration Example measurements Appendix
34 Generalized Network Analyzer Block Diagram Incident DUT Transmitted SOURCE Reflected SIGNAL SEPARATION INCIDENT (R) REFLECTED (A) TRANSMITTED (B) RECEIVER / DETECTOR PROCESSOR / DISPLAY
35 Source Supplies stimulus for system Swept frequency or power Traditionally NAs used separate source Most Agilent analyzers sold today have integrated, synthesized sources
36 Signal Separation SOURCE Incident Reflected DUT Transmitted SIGNAL SEPARATION INCIDENT (R) REFLECTED (A) TRANSMITTED (B) RECEIVER / DETECTOR measure incident signal for reference separate incident and reflected signals PROCESSOR / DISPLAY splitter bridge directional coupler Detector Test Port
37 Directivity Directivity is a measure of how well a coupler can separate signals moving in opposite directions (undesired leakage signal) (desired reflected signal) Test port Directional Coupler
38 Interaction of Directivity with the DUT (Without Error Correction) 0 DUT RL = 40 db Data Max Return Loss 30 Device Directivity Add in-phase 60 Frequency Directivity Device Data Min Add out-of-phase (cancellation) Directivity Device Data = Vector Sum
39 Detector Types Diode Scalar broadband (no phase information) SOURCE INCIDENT (R) Incident Reflected REFLECTED (A) DUT SIGNAL SEPARATION TRANSMITTED (B) RECEIVER / DETECTOR Transmitted RF DC AC PROCESSOR / DISPLAY Tuned Receiver RF IF = F LO ± F RF ADC / DSP Vector (magnitude and phase) IF Filter LO
40 Broadband Diode Detection Easy to make broadband Inexpensive compared to tuned receiver Good for measuring frequency-translating devices Improve dynamic range by increasing power Medium sensitivity / dynamic range 10 MHz 26.5 GHz
41 Narrowband Detection - Tuned Receiver ADC / DSP Best sensitivity / dynamic range Provides harmonic / spurious signal rejection Improve dynamic range by increasing power, decreasing IF bandwidth, or averaging Trade off noise floor and measurement speed 10 MHz 26.5 GHz
42 Comparison of Receiver Techniques 0 db Broadband (diode) detection 0 db Narrowband (tuned-receiver) detection -50 db -50 db -100 db -100 db -60 dbm Sensitivity < -100 dbm Sensitivity higher noise floor false responses high dynamic range harmonic immunity Dynamic range = maximum receiver power - receiver noise floor
43 Dynamic Range and Accuracy 100 Error Due to Interfering Signal 10 - Error (db, deg) magn error phase error Dynamic range is very important for measurement accuracy! Interfering signal (db)
44 T/R Versus S-Parameter Test Sets Transmission/Reflection Test Set S-Parameter Test Set Source Source Transfer switch R R A B A B Port 1 Port 2 Port 1 Port 2 Fwd DUT Fwd DUT Rev RF always comes out port 1 port 2 is always receiver response, one-port cal available RF comes out port 1 or port 2 forward and reverse measurements two-port calibration possible
45 Hld Cor PRm Hld Cor PRm 1 CH2 START MHz MHz START CH1 Duplexer Test - Tx-Ant and Ant-Rx S CH2 S 12 log MAG REF 0 db 10 db/ db 0 REF db/ 10 MAG log 21 CH1 1 STOP MHz MHz STOP MHz MHz PASS PASS 1_ db db _ 2 HP-IB STATUS Processor / Display Incident DUT Transmitted 50 MH-20GHz NETWORK ANYZER SOURCE Reflected ACTIVE CHANNEL RESPONSE ENTRY SIGNAL SEPARATION STIMULUS INSTRUMENT STATE R CHANNEL INCIDENT (R) REFLECTED (A) TRANSMITTED (B) T R L S RECEIVER / DETECTOR PORT 1 PORT 2 PROCESSOR / DISPLAY CH2 START MHz STOP MHz CH1 START MHz STOP MHz Hld PASS 2 markers limit lines pass/fail indicators linear/log formats grid/polar/smith charts Cor PRm 1 Hld 1 Cor Duplexer Test - Tx-Ant Ant-Rx and PRm S 12 log MAG REF 0 db 10 db/ CH2 db 0 REF db/ 10 MAG log 21 S CH MHz PASS MHz db _ db _
46 Internal Measurement Automation Simple: recall states More powerful: Test sequencing available on 8753/ 8720 families keystroke recording some advanced functions IBASIC available on 8712 family sophisticated programs custom user interfaces ABCDEFGHIJKLMNOPQRSTUVWXYZ / * = < > ( ) & "" ",. /? ; : ' [ ] 1 TO *WAI" 3 OFF;*WAI" 4 SSTOP" 5 CSPAN" HZ;*WAI" 7 OFF;:INIT1;*WAI" 8 ONCE" 9 ON" 10 BWID" 11 ON; *WAI" 12 'XFR:POW:RAT 1,0';DET NBAN; *WAI" 13 OFF;:INIT1;*WAI" 14 ONCE" 15 ON;*WAI" 16 END
47 Agilent s Series of HF Vector Analyzers Microwave 8720ET/ES series 13.5, 20, 40 GHz economical fast, small, integrated test mixers, high-power amps RF 8712ET/ES series 1.3, 3 GHz low cost narrowband and broadband detection IBASIC / LAN 8510C series 110 GHz in coax highest accuracy modular, flexible pulse systems Tx/Rx module test 8753ET/ES series 3, 6 GHz highest RF accuracy flexible hardware more features Offset and harmonic RF sweeps
48 Agilent s LF/RF Vector Analyzers Combination NA / SA 4395A/4396B 500 MHz (4395A), 1.8 GHz (4396B) impedance-measuring option fast, FFT-based spectrum analysis time-gated spectrum-analyzer option IBASIC standard test fixtures LF E5100A/B 180, 300 MHz economical fast, small target markets: crystals, resonators, filters equivalent-circuit models evaporation-monitor-function option
49 SPECTRUM ANALYZER 9 khz GHz Spectrum Analyzer / Tracking Generator RF in DUT LO IF 8563A Spectrum analyzer TG out f = IF Tracking generator DUT Key differences from network analyzer: one channel -- no ratioed or phase measurements More expensive than scalar NA (but better dynamic range) Only error correction available is normalization (and possibly open-short averaging) Poorer accuracy Small incremental cost if SA is required for other measurements
50 Agenda What measurements do we make? Network analyzer hardware Error models and calibration Example measurements Appendix Why do we even need error-correction and calibration? It is impossible to make perfect hardware It would be extremely expensive to make hardware good enough to eliminate the need for error correction
51 Calibration Topics What measurements do we make? Network analyzer hardware Error models and calibration measurement errors what is vector error correction? calibration types accuracy examples calibration considerations Example measurements Appendix
52 Measurement Error Modeling CAL RE-CAL Systematic errors due to imperfections in the analyzer and test setup assumed to be time invariant (predictable) Random errors vary with time in random fashion (unpredictable) main contributors: instrument noise, switch and connector repeatability Drift errors due to system performance changing after a calibration has been done primarily caused by temperature variation Measured Data Errors: SYSTEMATI C RANDO M Unknown Device DRIFT
53 Systematic Measurement Errors R Directivity A Crosstalk B DUT Frequency response reflection tracking (A/R) transmission tracking (B/R) Source Mismatch Load Mismatch Six forward and six reverse error terms yields 12 error terms for twoport devices
54 Types of Error Correction response (normalization) simple to perform only corrects for tracking errors stores reference trace in memory, thru then does data divided by memory vector requires more standards requires an analyzer that can measure phase accounts for all major sources of systematic error SHORT S 11a OPEN thru S 11m LOAD
55 What is Vector-Error Correction? Process of characterizing systematic error terms measure known standards remove effects from subsequent measurements 1-port calibration (reflection measurements) only 3 systematic error terms measured directivity, source match, and reflection tracking Full 2-port calibration (reflection and transmission measurements) 12 systematic error terms measured usually requires 12 measurements on four known standards (SOLT) Standards defined in cal kit definition file network analyzer contains standard cal kit definitions CAL KIT DEFINITION MUST MATCH ACTUAL CAL KIT USED! User-built standards must be characterized and entered into user cal kit
56 Reflection: One-Port Model RF in Ideal RF in Error Adapter 1 E D = Directivity S11 A E D E S S11A E RT E S = Reflection tracking = Source Match S11 M S11 M S11 M = Measured E RT S11 A = Actual To solve for error terms, we measure 3 standards to generate 3 equations and 3 unknowns S11M = ED + Assumes good termination at port two if testing two-port devices If using port 2 of NA and DUT reverse isolation is low (e.g., filter passband): assumption of good termination is not valid two-port error correction yields better results ERT S11A 1 - ES S11A
57 Before and After One-Port Calibration Return Loss (db) data before 1-port calibration VSWR 60 data after 1-port calibration MHz
58 RT S E RT E E D E S E L E L E TT S m E X S m E X m E S E RT E S S m E D RT S L E L E TT E m E X E m E X S E S RT S L E TT E E E X S m E X E m S E TT m D E TT S m E D E TT S m E X RT S E RT E E D E S E L E L E TT S m E X S m E X m E S RT E RT E D E S E L E TT S m E X S m E X E m S a 1 b 1 Two-Port Error Correction Forward model Port 1 EX Port 2 S 21 E b A TT 2 E S E D S 11 S 22 a A A 2 E L E RT S 12 A Reverse model Port 1 Port 2 E RT' S21 a A 1 E L' S 11 S 22 E ES' D' A A b 1 E TT' S 12 A E X' b 2 a 2 E D E S E RT E D' E S' ERT' = fwd directivity = fwd source match = fwd reflection tracking = rev directivity = rev source match = rev reflection tracking E L E TT E X E L' ETT' E X' = fwd load match = fwd transmission tracking = fwd isolation = rev load match = rev transmission tracking = rev isolation a 22 S )( m ( D E S ') ( )( ' ' ' ) ' ' S 12a = = E RT ( 1 + S TT ' E ' m E D )( ') ' ( )( 1 ' E S 11 D m E S ' E RT ( 1 )( + 22 D E m S ' ' E TT ) m '( D )( E S ' E TT ' ' ) ) Each actual S-parameter is a function of all four measured S-parameters Analyzer must make forward and reverse sweep to update any one S-parameter Luckily, you don't need to know these equations to use network analyzers!!! m D ( 1 )( E S a 21 = S X E m S m D' ( 1 )( E S a 11 = S D E m S 1 + ( )( 11 E RT ( )( ( ' )) m X E S E L E S E S ' RT S L ' ' E E E ') ' ( )( E L E TT S m E X ' RT S L E ' E + ( E )( ( ' )) 1 ' TT ' ' E ') ' ( )( TT ' ' E ') ( )( ' ' ) ' ) ' ) '
59 Crosstalk: Signal Leakage Between Test Ports During Transmission Can be a problem with: high-isolation devices (e.g., switch in open position) high-dynamic range devices (some filter stopbands) Isolation calibration adds noise to error model (measuring near noise floor of system) only perform if really needed (use averaging if necessary) if crosstalk is independent of DUT match, use two terminations if dependent on DUT match, use DUT with termination on output LOAD DUT DUT LOAD DUT
60 Convenient Generally not accurate No errors removed Errors and Calibration Standards UNCORRECTED RESPONSE FULL 2-PORT DUT thru DUT Easy to perform Use when highest accuracy is not required Removes frequency response error ENHANCED-RESPONSE Combines response and 1-port Corrects source match for transmission measurements SHORT OPEN LOAD DUT For reflection measurements Need good termination for high accuracy with twoport devices Removes these errors: Directivity Source match Reflection tracking 1-PORT SHORT OPEN LOAD Highest accuracy Removes these errors: Directivity Source, load match Reflection tracking Transmission tracking Crosstalk thru DUT SHORT OPEN LOAD
61 Calibration Summary Reflection Reflection tracking Test Set (cal type) T/R (one-port) S-parameter (two-port) SHORT OPEN Directivity LOAD Source match Load match * error can be corrected error cannot be corrected enhanced response cal corrects for source match during transmission measurements Transmission Transmission Tracking Crosstalk Source match Load match * ( ) Test Set (cal type) T/R S-parameter (response, isolation) (two-port)
62 Reflection Example Using a One-Port Cal Directivity: 40 db (.010) Load match: 18 db (.126) DUT 16 db RL (.158) 1 db loss (.891) Remember: convert all db values to linear for uncertainty calculations! -db ( ) 20 ρ or loss (linear) = (.891)(.126)(.891) =.100 Measurement uncertainty: -20 * log ( ) = 11.4 db (-4.6dB) -20 * log ( ) = 26.4 db (+10.4 db)
63 Using a One-Port Cal + Attenuator Directivity: 40 db (.010).158 Load match: 18 db (.126) 10 db attenuator (.316) SWR = 1.05 (.024) DUT 16 db RL (.158) 1 db loss (.891) Measurement uncertainty: -20 * log ( ) = 14.1 db (-1.9 db) -20 * log ( ) = 18.5 db (+2.5 db) (.891)(.316)(.126)(.316)(.891) =.010 (.891)(.024)(.891) =.019 Worst-case error = =.039 Low-loss bi-directional devices generally require two-port calibration for low measurement uncertainty
64 Transmission Example Using Response Cal RL = 14 db (.200) RL = 18 db (.126) Thru calibration (normalization) builds error into measurement due to source and load match interaction Calibration Uncertainty = (1 ± ρ S ρ L ) = (1 ± (.200)(.126) = ± 0.22 db
65 Filter Measurement with Response Cal Source match = 14 db (.200) DUT 1 db loss (.891) 16 db RL (.158) Load match = 18 db (.126) 1 (.126)(.158) =.020 (.126)(.891)(.200)(.891) =.020 Total measurement uncertainty: = db = db (.158)(.200) =.032 Measurement uncertainty = 1 ± ( ) = 1 ±.072 = db db
66 Measuring Amplifiers with a Response Cal Source match = 14 db (.200) DUT 16 db RL (.158) Load match = 18 db (.126) 1 (.126)(.158) =.020 (.158)(.200) =.032 Total measurement uncertainty: = db = db Measurement uncertainty = 1 ± ( ) = 1 ±.052 = db db
67 Source match = 35 db (.0178) Filter Measurements using the Enhanced Response Calibration Effective source match = 35 db! DUT 1 db loss (.891) 16 db RL (.158) Load match = 18 db (.126) Calibration Uncertainty = (1 ± ρ S ρ L ) = (1 ± (.0178)(.126) = ±.02 db 1 (.126)(.158) =.020 (.126)(.891)(.0178)(.891) =.0018 (.158)(.0178) =.0028 Measurement uncertainty = 1 ± ( ) = 1 ±.0246 = db db Total measurement uncertainty: = ± 0.24 db
68 Source match = 35 db (.0178) Using the Enhanced Response Calibration Plus an Attenuator 10 db attenuator (.316) SWR = 1.05 (.024 linear or 32.4 db) Analyzer load match =18 db (.126) DUT 1 db loss (.891) 16 db RL (.158) Effective load match = (.316)(.316)(.126) =.0366 (28.7dB) 1 (.0366)(.158) =.006 (.0366)(.891)(.0178)(.891) =.0005 (.158)(.0178) =.0028 Calibration Uncertainty = (1 ± ρ S ρ L ) = (1 ± (.0178)(.0366) = ±.01 db Measurement uncertainty = 1 ± ( ) = 1 ±.0093 = ± 0.08 db Total measurement uncertainty: = ± 0.09 db
69 Calculating Measurement Uncertainty After a Two-Port Calibration Corrected error terms: (8753ES GHz Type-N) Directivity = 47 db Source match = 36 db Load match = 47 db Refl. tracking =.019 db Trans. tracking =.026 db Isolation = 100 db Transmission uncertainty DUT 1 db loss (.891) 16 db RL (.158) Reflection uncertainty = ± (.. *.. *.. *. ) 2 a D a S a a L a RT m S S E S E S S E S E 1 = ± ( ( )) = ±.0088 = 16 db db, db (worst-case) = ± ( /.. *.. *. *.. *.. ) a a I a a S a a S L a L TT m = ±.0056 = 1 db ±0.05 db (worst-case) S S E S S E S S E E S E E 1 = ± ( / ( )) S
70 Response versus Two-Port Calibration Measuring filter insertion loss CH1 S21&M log MAG 1 db/ REF 0 db CH2 MEM log MAG 1 db/ REF 0 db Cor After two-port calibration After response calibration Cor Uncorrected x2 1 2 START MHz STOP MHz
71 ECal: Electronic Calibration (85060/90 series) Variety of modules cover 30 khz to 26.5 GHz Six connector types available (50 Ω and 75 Ω) Single-connection reduces calibration time makes calibrations easy to perform minimizes wear on cables and standards eliminates operator errors Highly repeatable temperaturecompensated terminations provide excellent accuracy 85093A Electronic Calibration Module 30 khz - 6 GHz Microwave modules use a transmission line shunted by PIN-diode switches in various combinations
72 Adapter Considerations reflection from adapter leakage signal Coupler directivity = 40 db desired signal ρ measured = Directivity + adapter + ρ ρ DUT Adapter DUT Termination DUT has SMA (f) connectors Worst-case System Directivity Adapting from APC-7 to SMA (m) APC-7 calibration done here 28 db APC-7 to SMA (m) SWR: db APC-7 to N (f) + N (m) to SMA (m) SWR:1.05 SWR: db APC-7 to N (m) + N (f) to SMA (f) + SMA (m) to (m) SWR:1.05 SWR:1.25 SWR:1.15
73 Calibrating Non-Insertable Devices When doing a through cal, normally test ports mate directly cables can be connected directly without an adapter result is a zero-length through What is an insertable device? has same type of connector, but different sex on each port has same type of sexless connector on each port (e.g. APC-7) What is a non-insertable device? one that cannot be inserted in place of a zerolength through has same connectors on each port (type and sex) has different type of connector on each port (e.g., waveguide on one port, coaxial on the other) What calibration choices do I have for non- DUT
74 Swap Equal Adapters Method Port 1 DUT Port 2 Adapter Port 1 A Port 2 Accuracy depends on how well the adapters are matched - loss, electrical length, match and impedance should all be equal 1. Transmission cal using adapter A. Port 1 Adapter Port 2 B 2. Reflection cal using adapter B. Port 1 DUT Adapter Port 2 B 3. Measure DUT using adapter B.
75 Adapter Removal Calibration Calibration is very accurate and traceable In firmware of 8753, 8720 and 8510 series Also accomplished with ECal modules (85060/90) Uses adapter with same connectors as DUT Must specify electrical length of adapter to within 1/4 wavelength of highest frequency (to avoid phase ambiguity) Port 1 DUT Port 2 Cal Port 1 Adapter Port 2 Adapter B Cal Set 1 Port 1 Cal Adapter Adapter B Port 2 Cal Set 2 [CAL] [MORE] [MODIFY CAL SET] [ADAPTER REMOVAL] 1. Perform 2-port cal with adapter on port 2. Save in cal set Perform 2-port cal with adapter on port 1. Save in cal set Use ADAPTER REMOVAL to generate new cal set. Port 1 DUT Adapter B Port 2 4. Measure DUT without cal adapter.
76 Thru-Reflect-Line (TRL) Calibration We know about Short-Open-Load-Thru (SOLT) calibration... What is TRL? A two-port calibration technique Good for noncoaxial environments (waveguide, fixtures, wafer probing) Uses the same 12-term error model as the more common SOLT cal Uses practical calibration standards that TRL was developed for noncoaxial microwave are easily fabricated and characterized Two variations: TRL (requires 4 receivers) measurements and TRL* (only three receivers needed) Other variations: Line-Reflect-Match (LRM), Thru-Reflect-Match (TRM), plus many others
77 Agenda What measurements do we make? Network analyzer hardware Error models and calibration Example measurements Appendix
78 Frequency Sweep - Filter Test CH1 S 21 log MAG 10 db/ REF 0 db CH1 S 11 log MAG 5 db/ REF 0 db Cor 69.1 db Stopba nd rejectio n START MHz STOP MHz Cor CENTER MHz CH1 S21 log MAG 1 db/ REF 0 db m1: GHz db m2-ref: GHz 0.00 db ref 2 SPAN MHz Return loss Insertion loss Cor x2 1 2 START MHz STOP MHz
79 Optimize Filter Measurements with Swept-List Mode PRm CH1 S21 log MAG 12 db/ REF 0 db Segment 3: 29 ms (108 points, -10 dbm, 6000 Hz) Linear sweep: 676 ms (201 pts, 300 Hz, -10 dbm) Swept-list sweep: 349 ms (201 pts, variable BW's & power) PASS Segment 1: 87 ms (25 points, +10 dbm, 300 Hz) Segment 5: 129 ms (38 points, +10 dbm, 300 Hz) START MHz STOP MHz Segments 2,4: 52 ms (15 points, +10 dbm, 300 Hz)
80 Power Sweeps - Compression Output Power (dbm) Compression region Linear region (slope = small-signal gain) Saturated output power Input Power (dbm)
81 Power Sweep - Gain Compression CH1 S21 1og MAG 1 db/ REF 32 db db 12.3 dbm db compression: input power resulting in 1 db drop in gain START -10 dbm CW MHz STOP 15 dbm
82 AM (db) PM (deg) Amplitude AM to PM Conversion Measure of phase deviation caused by amplitude variations Power sweep Mag(Am i n ) DUT AM can be undesired: supply ripple, fading, thermal AM can be desired: modulation (e.g. QAM) Test Stimulus Time Amplitude Q AM - PM Conversion = Mag(Pm ) (deg/d out Mag(Am B) in ) AM (db) PM (deg) Output Response Time Mag(AM o ut ) Mag(Pm o ut ) AM to PM conversion can cause bit errors I
83 Measuring AM to PM Conversion 1:Transmission Log Mag 1.0 db/ Ref db 2:Transmission /M Phase 5.0 deg/ Ref deg Ch1:Mkr dbm db Ch2:Mkr db 0.86 deg 1 2 Use transmission setup with a power sweep Display phase of S21 AM - PM = 0.86 deg/db 2 Start dbm Start dbm 1 CW MHz CW MHz 1 Stop 0.00 dbm Stop 0.00 dbm
84 Agenda What measurements do we make? Network analyzer hardware Error models and calibration Example measurements Appendix Advanced Topics time domain frequency-translating devices high-power amplifiers extended dynamic range multiport devices in-fixture measurements crystal resonators balanced/differential Inside the network analyzer Challenge quiz!
85 Time-Domain Reflectometry (TDR) What is TDR? time-domain reflectometry analyze impedance versus time distinguish between inductive and capacitive transitions With gating: analyze transitions analyzer standards inductive transition impedance Zo capacitive transition non-zo transmission line time
86 TDR Basics Using a Network Analyzer start with broadband frequency sweep (often requires microwave VNA use inverse-fourier transform to compute time-domain resolution inversely proportionate to frequency span Time Domain Frequency Domain F -1 CH1 S22 Re 50 mu/ REF 0 U t f Cor 20 GHz 6 GHz t 0F(t)*dt Integrate 1/s*F(s) TDR F -1 t f CH1 START 0 s STOP 1.5 ns
87 Time-Domain Gating TDR and gating can remove undesired reflections (a form of error correction) Only useful for broadband devices (a load or thru for example) Define gate to only include DUT CH1 S11&M log MAG 5 db/ REF 0 db Use two-port calibration PRm Cor CH1 MEM Re 20 mu/ REF 0 U PRm Cor RISE TIME ps mm 1 1: mu 638 ps 2: mu 668 ps 3: mu 721 ps Gate 2 1: db GHz 2: db GHz 2 3 CH1 START 0 s Thru in time domain STOP 1.5 ns 1 START GHz Thru in frequency domain, with and without gating STOP GHz
88 Ten Steps for Performing TDR 1. Set up desired frequency range (need wide span for good spatial resolution) 2. Under SYSTEM, transform menu, press "set freq low pass" 3. Perform one- or two-port calibration 4. Select S11 measurement * 5. Turn on transform (low pass step) * 6. Set format to real * 7. Adjust transform window to trade off rise time with ringing and overshoot * 8. Adjust start and stop times if desired 9. For gating: set start and stop frequencies for gate turn gating on * adjust gate shape to trade off resolution with ripple * 10. To display gated response in frequency domain * If using turn two transform channels off (even (leave if coupled), gating these on) parameters * must be set independently change format second to log-magnitude channel *
89 Time-Domain Transmission RF Input RF Output Main Wave Leakage CH1 S21 log MAG 15 db/ REF 0 db Cor Triple Travel CH1 S21 log MAG 10 db/ REF 0 db Cor RF Leakage Surface Wave Triple Travel Gate off Gate on START -1 us STOP 6 us
90 Time-Domain Filter Tuning Deterministic method used for tuning cavity-resonator filters Traditional frequencydomain tuning is very difficult: lots of training needed may take 20 to 90 minutes to tune a single filter Need VNA with fast sweep speeds and fast timedomain processing
91 Filter Reflection in Time Domain Set analyzer s center frequency = center frequency of the filter Measure S 11 or S 22 in the time domain Nulls in the time-domain response correspond to individual resonators in filter
92 Tuning Resonator #3 Easier to identify mistuned resonator in time-domain: null #3 is missing Hard to tell which resonator is mistuned from frequencydomain response Adjust resonators by minimizing null Adjust coupling apertures using the peaks in-between the dips
93 Frequency-Translating Devices Medium-dynamic range measurements (35 db) 8753ES 1 2 Ref In Attenuator Filter Attenuator FREQ OFFS ON off LO MENU DOWN CONVERTER UP CONVERTER RF > LO High-dynamic range measurements (100 db) 8753ES Ref in Ref out Reference mixer Start: 900 MHz Stop: 650 MHz Fixed LO: 1 GHz LO power: 13 dbm Start: 100 MHz Stop: 350 MHz RF < LO VIEW MEASURE RETURN Filter Attenuator CH1 CONV MEAS log MAG 10 db/ REF 10 db Attenuat or DUT Attenuator START MHz STOP MHz ESG-D4000A Powe r splitt er
94 High-Power Amplifiers 8753ES Preamp Ref In Source Preamp AUT DUT R A B AUT +43 dbm max input (20 watts!) 8720ES Option A High-Power Amplifier Test System
95 High-Dynamic Range CH1 MEM LOG 15 db/ REF 3 db Measurements CH2 MEM LOG 15 db/ REF 3 db PRm Cor Avg 10 PRm Standard 8753ES Cor Avg ES Special Option H16 CH1 START MHz CH2 START MHz STOP MHz STOP MHz
96 Multiport Device Test 8753 H39 CH1 S 21 log MAG 10 db/ REF 0 db 1_ db CH2 S 12 log MAG 10 db/ REF 0 db 1_ db MHz PRm Duplexer Test - Tx-Ant and Ant-Rx Cor 1 1 Hld PASS MHz PRm Cor PASS Hld CH1 START MHz STOP MHz CH2 START MHz STOP MHz 2 Multiport analyzers and test sets: improve throughput by reducing the number of connections to DUTs with more than two ports allow simultaneous viewing of two paths (good for tuning duplexers) include mechanical or solid-state switches, 50 or 75 ohms degrade raw performance so calibration is a must (use two-port cals whenever possible) Agilent offers a variety of standard and custom multiport analyzers and test sets
97 87050E/87075C Standard Multiport Test Sets For use with 8712E family 50 Ω: 3 MHz to 2.2 GHz, 4, 8, or 12 ports 75 Ω: 3 MHz to 1.3 GHz, 6 or 12 ports Test Set Cal and SelfCal dramatically improve calibration times Systems offer fully-specified performance at test ports Once a month: perform a Test Set Cal with external standards to remove systematic errors in the analyzer, test set, cables, and fixture Test Set Cal Fixture SelfCal DUT Once an hour: automatically perform a SelfCal using internal standards to remove systematic errors in the analyzer and test set
98 Test Set Cal Eliminates Redundant Connections of Calibration Standards Reflection Connections Through Connections 12-port 12-port 8-port 8-port 4-port 4-port Test Set Cal Traditional VNA Calibration
99 In-Fixture Measurements Measurement problem: coaxial calibration plane is not the same as the in-fixture measurement plane Calibration plane Measurement plane Fixture E D E S DUT E T Error correction with coaxial calibration Loss Phase shift Mismatch
100 Characterizing Crystal Resonators/Filters E5100A/B Network Analyzer Ch1 Z: R phase 40 / REF 0 1: U MHz Min Cor 1 START MHz SEG START STOP POINTS POWER IFBW STOP MHz MHz MHz dbm 200Hz > MHz END MHz dbm 200Hz Example of crystal resonator measurement
101 Balanced-Device Measurements ATN-4000 series (4-port test set + software) measure tough singled-ended devices like couplers measure fully-balanced or single-ended-to-balanced DUTs characterize mode conversions (e.g. common-to-differential) incorporates 4-port error correction for exceptional accuracy works with 8753ES and 8720ES analyzers more info at Channel Partner
102 Traditional Scalar Analyzer Incident DUT Transmitted SOURCE Reflected processor/display source INCIDENT (R) REFLECTED (A) SIGNAL SEPARATION TRANSMITTED (B) RECEIVER / DETECTOR PROCESSOR / DISPLAY Example: 8757D/E requires external detectors, couplers, bridges, splitters good for low-cost microwave scalar applications RF R A B RF R A B Detector Detector Reflection Bridge DUT Termination DUT Detector Transmission
103 Directional Coupler Directivity Coupling Factor (fwd) x Loss (through arm) Directivity = Isolation (rev) Directivity (db) = Isolation (db) - Coupling Factor (db) - Loss (db) 50 db 20 db Examples: Test port Directivity = 50 db - 20 db = 30 db 50 db 30 db 10 db Test port Directivity = 50 db - 30 db - 10 db = 10 db 60 db 20 db 10 db Test port Directivity = 60 db - 20 db - 10 db = 30 db
104 One Method of Measuring Coupler Directivity 1.0 (0 db) (reference) Coupler Directivity 35 db (.018) Source short.018 (35 db) (normalized) Directivity = 35 db - 0 db = 35 db Source load Assume perfect load (no reflection)
105 Directional Bridge 50 Ω 50 Ω Detector 50 Ω Test Port 50-ohm load at test port balances the bridge -- detector reads zero Non-50-ohm load imbalances bridge Measuring magnitude and phase of imbalance gives complex impedance "Directivity" is difference between maximum and minimum balance
106 NA Hardware: Front Ends, Mixers Versus Samplers SOURCE INCIDENT (R) Incident Reflected REFLECTED (A) DUT SIGNAL SEPARATION TRANSMITTED (B) RECEIVER / DETECTOR Transmitted PROCESSOR / DISPLAY ADC / DSP Sampler-based front end S ADC / DSP Mixer-based front end It is cheaper and easier to make broadband front ends using samplers instead of mixers Harmonic generator f frequency "comb"
107 Three Versus Four-Receiver Analyzers Source Source Transfer switch Transfer switch R R1 A B A B R2 Port 1 Port 2 3 receivers more economical TRL*, LRM* cals only includes: 8753ES 8720ES (standard) Port 1 Port 2 4 receivers more expensive true TRL, LRM cals includes: 8720ES (option 400) 8510C
108 Why Are Four Receivers Better Than Three? TRL TRL* TRL* 8720ES Option 400 adds fourth sampler, allowing full TRL calibration assumes the source and load match of a test port are equal (port symmetry between forward and reverse measurements) this is only a fair assumption for three-receiver network analyzers TRL four receivers are necessary to make the required measurements TRL and TRL* use identical calibration standards In noncoaxial applications, TRL achieves better source and load match correction than TRL* What about coaxial applications? SOLT is usually the preferred calibration method coaxial TRL can be more accurate than SOLT, but not commonly used
109 Challenge Quiz 1. Can filters cause distortion in communications systems? A. Yes, due to impairment of phase and magnitude response B. Yes, due to nonlinear components such as ferrite inductors C. No, only active devices can cause distortion D. No, filters only cause linear phase shifts E. Both A and B above 2. Which statement about transmission lines is false? A. Useful for efficient transmission of RF power B. Requires termination in characteristic impedance for low VSWR C. Envelope voltage of RF signal is independent of position along line D. Used when wavelength of signal is small compared to length of line E. Can be realized in a variety of forms such as coaxial, waveguide, microstrip 3. Which statement about narrowband detection is false? A. Is generally the cheapest way to detect microwave signals B. Provides much greater dynamic range than diode detection C. Uses variable-bandwidth IF filters to set analyzer noise floor D. Provides rejection of harmonic and spurious signals E. Uses mixers or samplers as downconverters
110 Challenge Quiz (continued) 4. Maximum dynamic range with narrowband detection is defined as: A. Maximum receiver input power minus the stopband of the device under te B. Maximum receiver input power minus the receiver's noise floor C. Detector 1-dB-compression point minus the harmonic level of the source D. Receiver damage level plus the maximum source output power E. Maximum source output power minus the receiver's noise floor 5. With a T/R analyzer, the following error terms can be corrected: A. Source match, load match, transmission tracking B. Load match, reflection tracking, transmission tracking C. Source match, reflection tracking, transmission tracking D. Directivity, source match, load match E. Directivity, reflection tracking, load match 6. Calibration(s) can remove which of the following types of measurement A. Systematic and drift B. Systematic and random C. Random and drift D. Repeatability and systematic E. Repeatability and drift
111 Challenge Quiz (continued) 7. Which statement about TRL calibration is false? A. Is a type of two-port error correction B. Uses easily fabricated and characterized standards C. Most commonly used in noncoaxial environments D. Is not available on the 8720ES family of microwave network analyzers E. Has a special version for three-sampler network analyzers 8. For which component is it hardest to get accurate transmission and reflection measurements when using a T/R network analyzer? A. Amplifiers because output power causes receiver compression B. Cables because load match cannot be corrected C. Filter stopbands because of lack of dynamic range D. Mixers because of lack of broadband detectors E. Attenuators because source match cannot be corrected 9. Power sweeps are good for which measurements? A. Gain compression B. AM to PM conversion C. Saturated output power
112 Answers to Challenge Quiz 1. E 2. C 3. A 4. B 5. C 6. A 7. D 8. B 9. E
Network Analysis Basics
Adolfo Del Solar Application Engineer adolfo_del-solar@agilent.com MD1010 Network B2B Agenda Overview What Measurements do we make? Network Analyzer Hardware Error Models and Calibration Example Measurements
More informationAgilent ENA Series 2, 3 and 4 Port RF Network Analyzers
gilent EN Series 2, 3 and 4 Port RF Network nalyzers 蔡明汎 gilent EO Project Manager (07)3377603 Email:ming-fan_tsai@agilent.com OTS:0800-047866 EN 1 genda What measurements do we make? Network nalyzer Hardware
More informationAgilent AN Applying Error Correction to Network Analyzer Measurements
Agilent AN 287-3 Applying Error Correction to Network Analyzer Measurements Application Note 2 3 4 4 5 6 7 8 0 2 2 3 3 4 Table of Contents Introduction Sources and Types of Errors Types of Error Correction
More informationConfiguration of PNA-X, NVNA and X parameters
Configuration of PNA-X, NVNA and X parameters VNA 1. S-Parameter Measurements 2. Harmonic Measurements NVNA 3. X-Parameter Measurements Introducing the PNA-X 50 GHz 43.5 GHz 26.5 GHz 13.5 GHz PNA-X Agilent
More informationFor EECS142, Lecture presented by Dr. Joel Dunsmore. Slide 1 Welcome to Network Analyzer Basics.
For EECS142, Lecture presented by Dr. Joel Dunsmore Slide 1 Welcome to Network Analyzer Basics. Slide 2 One of the most fundamental concepts of high-frequency network analysis involves incident, reflected
More informationVector Network Analyzer Application note
Vector Network Analyzer Application note Version 1.0 Vector Network Analyzer Introduction A vector network analyzer is used to measure the performance of circuits or networks such as amplifiers, filters,
More informationKeysight Technologies In-Fixture Measurements Using Vector Network Analyzers. Application Note
Keysight Technologies In-Fixture Measurements Using Vector Network Analyzers Application Note Introduction This application note describes the use of vector network analyzers when making measurements of
More informationapplication In-Fixture Measurements Using Vector Network Analyzers Network Analysis Solutions Application Note
application Network Analysis Solutions In-Fixture Measurements Using Vector Network Analyzers Application Note 1287-9 Table of contents Introduction..................................................3 The
More informationVector Network Analyzer
Vector Network Analyzer VNA Basics VNA Roadshow Budapest 17/05/2016 Content Why Users Need VNAs VNA Terminology System Architecture Key Components Basic Measurements Calibration Methods Accuracy and Uncertainty
More informationUnderstanding the Fundamental Principles of Vector Network Analysis. Application Note
Understanding the Fundamental Principles of Vector Network Analysis Application Note Table of Contents Introduction... 3 Measurements in Communications Systems... 3 Importance of Vector Measurements...
More informationNetwork Analysis Seminar. Cables measurement
Network Analysis Seminar Cables measurement Agenda 1. Device Under Test: Cables & Connectors 2. Instrument for cables testing: Network Analyzer 3. Measurement: Frequency Domain 4. Measurement: Time Domain
More informationKeysight Technologies Applying Error Correction to Vector Network Analyzer Measurements. Application Note
Keysight Technologies Applying Error Correction to Vector Network Analyzer Measurements Application Note Introduction Only perfect test equipment would not need correction. Imperfections exist in even
More informationKeysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note
Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples Application Note Introduction Both the magnitude and phase behavior of a component are critical to the performance of
More informationRF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand
RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand Advanced VNA Measurements Agenda Overview of the PXIe-5632 Architecture SW Experience Overview of VNA Calibration
More informationHP Archive. This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web!
HP Archive This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web! On-line curator: Glenn Robb This document is for FREE distribution only!
More informationExpanding Impedance Measurement to Nanoscale:
Expanding Impedance Measurement to Nanoscale: Coupling the Power of Scanning Probe Microscopy with Performance Network Analyzer (PNA) Hassan Tanbakuchi Senior Research Scientist Agilent Technologies Agilent
More informationVector network analysis Calibration and advanced measurements
Vector network analysis Calibration and advanced measurements Application examples (I) Production-line testing On-wafer testing Datum VNA training Titel R&S 2 Canada 2 Application examples (II) RCS measurement
More informationMillimeter Signal Measurements: Techniques, Solutions and Best Practices
New Network Analyzer platform Millimeter Signal Measurements: Techniques, Solutions and Best Practices Phase Noise measurements update 1 N522XA PNA Series Network Analyzer Introducing Highest Performance
More informationThere is a twenty db improvement in the reflection measurements when the port match errors are removed.
ABSTRACT Many improvements have occurred in microwave error correction techniques the past few years. The various error sources which degrade calibration accuracy is better understood. Standards have been
More informationMeasurements with Scattering Parameter By Joseph L. Cahak Copyright 2013 Sunshine Design Engineering Services
Measurements with Scattering Parameter By Joseph L. Cahak Copyright 2013 Sunshine Design Engineering Services Network Analyzer Measurements In many RF and Microwave measurements the S-Parameters are typically
More informationOvercoming Mixer Measurement Challenges
Overcoming Mixer Measurement Challenges October 10, 2002 presented by: Robb Myer Dave Ballo Today we will be looking at overcoming measurements challenges associated with frequency translating devices
More informationPlatform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies
Platform Migration 8510 to PNA Graham Payne Application Engineer Agilent Technologies We set the standard... 8410 8510 When we introduced the 8510, we changed the way S-parameter measurements were made!
More informationSignal Integrity Testing with a Vector Network Analyzer. Neil Jarvis Applications Engineer
Signal Integrity Testing with a Vector Network Analyzer Neil Jarvis Applications Engineer 1 Agenda RF Connectors A significant factor in repeatability and accuracy Selecting the best of several types for
More informationAgilent PN Testing amplifiers and active devices with the Agilent 8510C Network Analyzer. Product Note
Agilent PN 8510-18 Testing amplifiers and active devices with the Agilent 8510C Network Analyzer Product Note Table of Contents 3 Introduction 4 Amplifier parameters 5 Measurement setup 7 Linear measurements
More informationAgilent Technologies Gli analizzatori di reti della serie-x
Agilent Technologies Gli analizzatori di reti della serie-x Luigi Fratini 1 Introducing the PNA-X Performance Network Analyzer For Active Device Test 500 GHz & beyond! 325 GHz 110 GHz 67 GHz 50 GHz 43.5
More informationKeysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz
Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz Application Note Overview This application note describes accuracy considerations
More informationAgilent Accurate Measurement of Packaged RF Devices. White Paper
Agilent Accurate Measurement of Packaged RF Devices White Paper Slide #1 Slide #2 Accurate Measurement of Packaged RF Devices How to Measure These Devices RF and MW Device Test Seminar 1995 smafilt.tif
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent 2-Port and 4-Port PNA-X Network Analyzer N5249A - 10 MHz to 8.5 GHz N5241A - 10 MHz to 13.5 GHz N5242A - 10
More informationNetwork Analysis Back to Basics
Network Analysis Back to Basics Objectives Review RF basics (transmission lines, etc.) Understand what types of measurements are made with vector network analyzers (VNAs) Examine architectures of modern
More informationWhat s inside. Highlights. Welcome. Mixer test third in a series. New time-domain technique for measuring mixer group delay
What s inside 2 New time-domain technique for measuring mixer group delay 3 Uncertainty in mixer group-delay measurements 5 Isolation a problem? Here s how to measure mixer group delay 6 Low-power mixer
More informationUnderstanding RF and Microwave Analysis Basics
Understanding RF and Microwave Analysis Basics Kimberly Cassacia Product Line Brand Manager Keysight Technologies Agenda µw Analysis Basics Page 2 RF Signal Analyzer Overview & Basic Settings Overview
More informationMeasurements 2: Network Analysis
Measurements 2: Network Analysis Fritz Caspers CAS, Aarhus, June 2010 Contents Scalar network analysis Vector network analysis Early concepts Modern instrumentation Calibration methods Time domain (synthetic
More informationNetwork Analyzers. R3765G/3767G Series. R3765G/67G Series Network Analyzers. 300 khz to 3.8 GHz/300 khz to 8 GHz
(Photo is R3767CG) R3765G/67G Series Network Analyzers The R3765G/67G-series network analyzers are vector network analyzers that incorporate a new RF circuit analysis technique. The measuring frequency
More informationImpedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR 304/1 DATA SHEET Frequency range: 300 khz to 3.2 GHz Measured parameters: S11, S21, S12, S22 Dynamic range of transmission measurement magnitude: 135 db Measurement time
More informationDepartment of Electrical and Computer Engineering ECE332. Lab 3: High Frequency Measurements
Department of Electrical and Computer Engineering ECE332 Version: 1.3.1 Revised: April 30, 2011 Contents 1 Pre-Lab Assignment 2 2 Introduction 2 2.1 Vector Network Analyzer.............................
More informationPNA Family Microwave Network Analyzers (N522x/3x/4xB) CONFIGURATION GUIDE
PNA Family Microwave Network Analyzers (N522x/3x/4xB) CONFIGURATION GUIDE Table of Contents PNA Family Network Analyzer Configurations... 05 Test set and power configuration options...05 Hardware options...
More informationAgilent Time Domain Analysis Using a Network Analyzer
Agilent Time Domain Analysis Using a Network Analyzer Application Note 1287-12 0.0 0.045 0.6 0.035 Cable S(1,1) 0.4 0.2 Cable S(1,1) 0.025 0.015 0.005 0.0 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Frequency (GHz) 0.005
More information9 Hints for Making Better Measurements Using RF Signal Generators. Application Note 1390
9 Hints for Making Better Measurements Using RF Signal Generators Application Note 1390 Signal sources provide precise, highly stable test signals for a variety of component and system test applications.
More informationKeysight 2-Port and 4-Port PNA-X Network Analyzer
Keysight 2-Port and 4-Port PNA-X Network Analyzer N5249A - 0 MHz to 8.5 GHz N524A - 0 MHz to 3.5 GHz N5242A - 0 MHz to 26.5 GHz Data Sheet and Technical Specifications Documentation Warranty THE MATERIAL
More information772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler
72 772D coaxial dual-directional coupler 773D coaxial directional coupler 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler 777D coaxial dual-directional coupler 778D coaxial
More informationLimitations And Accuracies Of Time And Frequency Domain Analysis Of Physical Layer Devices
Limitations And Accuracies Of Time And Frequency Domain Analysis Of Physical Layer Devices Outline Short Overview Fundamental Differences between TDR & Instruments Calibration & Normalization Measurement
More informationAgilent PNA Microwave Network Analyzers
Agilent PNA Microwave Network Analyzers Application Note 1408-1 Mixer Transmission Measurements Using The Frequency Converter Application Introduction Frequency-converting devices are one of the fundamental
More informationIntroduction to On-Wafer Characterization at Microwave Frequencies
Introduction to On-Wafer Characterization at Microwave Frequencies Chinh Doan Graduate Student University of California, Berkeley Introduction to On-Wafer Characterization at Microwave Frequencies Dr.
More informationAgilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software
Test System Overview Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software Test System Overview The Agilent Technologies test system is designed to verify the performance of the
More informationECE 4265/6265 Laboratory Project 7 Network Analyzer Calibration
ECE 4265/6265 Laboratory Project 7 Network Analyzer Calibration Objectives The purpose of this lab is to introduce the concepts of calibration and error correction for microwave s-parameter measurements.
More informationKeysight Technologies 8 Hints for Making Better Measurements Using RF Signal Generators. Application Note
Keysight Technologies 8 Hints for Making Better Measurements Using RF Signal Generators Application Note 02 Keysight 8 Hints for Making Better Measurements Using RF Signal Generators - Application Note
More informationKeysight Technologies PNA-X Series Microwave Network Analyzers
Keysight Technologies PNA-X Series Microwave Network Analyzers Active-Device Characterization in Pulsed Operation Using the PNA-X Application Note Introduction Vector network analyzers (VNA) are the common
More informationMICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:
Microwave section consists of Basic Microwave Training Bench, Advance Microwave Training Bench and Microwave Communication Training System. Microwave Training System is used to study all the concepts of
More informationAgilent Network Analysis Applying the 8510 TRL Calibration for Non-Coaxial Measurements. Product Note A
Agilent Network Analysis Applying the 8510 TRL Calibration for Non-Coaxial Measurements Product Note 8510-8A Introduction This note describes how the Agilent 8510 network analyzer can be used to make error-corrected
More informationExternal Source Control
External Source Control X-Series Signal Analyzers Option ESC DEMO GUIDE Introduction External source control for X-Series signal analyzers (Option ESC) allows the Keysight PXA, MXA, EXA, and CXA to control
More informationMigrating 4195A to E5061B LF-RF Network Analyzer. April 2010 Agilent Technologies
Migrating 4195A to E61B LF-RF Network Analyzer April 2010 Agilent Technologies Page 1 Contents Overview of 4195A to E61B migration Migrating 4195A to E61B in network measurements Migrating 4195A to E61B
More informationCompact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES
Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES Frequency range: 9 khz - 6.5 or 8.5 GHz Measured parameters: S11, S12, S21, S22 Wide output power adjustment range: -50 dbm to +5 dbm
More informationAV3672 Series Vector Network Analyzer
AV3672 Series Vector Network Analyzer AV3672A/B/C/D/E (10MHz 13.5 GHz/26.5 GHz/43.5 GHz/50 GHz/67 GHz) Product Overview: AV3672 series vector network analyzer include AV3672A (10MHz 13.5GHz), AV3672B (10MHz
More informationKeysight Technologies
Keysight Technologies Generating Signals Basic CW signal Block diagram Applications Analog Modulation Types of analog modulation Block diagram Applications Digital Modulation Overview of IQ modulation
More informationLarge-Signal Measurements Going beyond S-parameters
Large-Signal Measurements Going beyond S-parameters Jan Verspecht, Frans Verbeyst & Marc Vanden Bossche Network Measurement and Description Group Innovating the HP Way Overview What is Large-Signal Network
More informationNATIONAL UNIVERSITY of SINGAPORE
NATIONAL UNIVERSITY of SINGAPORE Faculty of Engineering Electrical & Computer Engineering Department EE3104 Introduction to RF and Microwave Systems & Circuits Experiment 1 Familiarization on VNA Calibration
More informationApplication Note 5525
Using the Wafer Scale Packaged Detector in 2 to 6 GHz Applications Application Note 5525 Introduction The is a broadband directional coupler with integrated temperature compensated detector designed for
More informationReceiver Design. Prof. Tzong-Lin Wu EMC Laboratory Department of Electrical Engineering National Taiwan University 2011/2/21
Receiver Design Prof. Tzong-Lin Wu EMC Laboratory Department of Electrical Engineering National Taiwan University 2011/2/21 MW & RF Design / Prof. T. -L. Wu 1 The receiver mush be very sensitive to -110dBm
More informationTermination Insensitive Mixers By Howard Hausman President/CEO, MITEQ, Inc. 100 Davids Drive Hauppauge, NY
Termination Insensitive Mixers By Howard Hausman President/CEO, MITEQ, Inc. 100 Davids Drive Hauppauge, NY 11788 hhausman@miteq.com Abstract Microwave mixers are non-linear devices that are used to translate
More informationPLANAR 814/1. Vector Network Analyzer
PLANAR 814/1 Vector Network Analyzer Frequency range: 100 khz 8 GHz Measured parameters: S11, S12, S21, S22 Wide output power range: -60 dbm to +10 dbm >150 db dynamic range (1 Hz IF bandwidth) Direct
More informationNetwork, Spectrum, and Impedance Evaluation of Electronic Circuits and Components
H Network, Spectrum, and Impedance Evaluation of Electronic Circuits and Components Application Note 1308-1 HP 4395A/HP 4396B Network/Spectrum/Impedance Analyzer 1 Introduction With the current trends
More informationKeysight Technologies PNA Microwave Network Analyzers
Keysight Technologies PNA Microwave Network Analyzers Application Note Banded Millimeter-Wave Measurements with the PNA 02 Keysight PNA Microwave Network Analyzers Application Note Table of Contents Introduction...
More informationNew Ultra-Fast Noise Parameter System... Opening A New Realm of Possibilities in Noise Characterization
New Ultra-Fast Noise Parameter System... Opening A New Realm of Possibilities in Noise Characterization David Ballo Application Development Engineer Agilent Technologies Gary Simpson Chief Technology Officer
More informationKeysight Technologies Accurate Mixer Measurements Using the ENA RF Networks Analyzers Frequency-Offset Mode. Application Note
Keysight Technologies Accurate Mixer Measurements Using the ENA RF Networks Analyzers Frequency-Offset Mode Application Note 1 Measurement Parameters of the Mixer The ENA FOM offers two advanced mixer
More informationME1000 RF Circuit Design. Lab 4. Filter Characterization using Vector Network Analyzer (VNA)
ME1000 RF Circuit Design Lab 4 Filter Characterization using Vector Network Analyzer (VNA) This courseware product contains scholarly and technical information and is protected by copyright laws and international
More informationUtilizzo del Time Domain per misure EMI
Utilizzo del Time Domain per misure EMI Roberto Sacchi Measurement Expert Manager - Europe 7 Giugno 2017 Compliance EMI receiver requirements (CISPR 16-1-1 ) range 9 khz - 18 GHz: A normal +/- 2 db absolute
More informationEXPERIMENT EM3 INTRODUCTION TO THE NETWORK ANALYZER
ECE 351 ELECTROMAGNETICS EXPERIMENT EM3 INTRODUCTION TO THE NETWORK ANALYZER OBJECTIVE: The objective to this experiment is to introduce the student to some of the capabilities of a vector network analyzer.
More informationDirect-Conversion I-Q Modulator Simulation by Andy Howard, Applications Engineer Agilent EEsof EDA
Direct-Conversion I-Q Modulator Simulation by Andy Howard, Applications Engineer Agilent EEsof EDA Introduction This article covers an Agilent EEsof ADS example that shows the simulation of a directconversion,
More informationReceiver Architecture
Receiver Architecture Receiver basics Channel selection why not at RF? BPF first or LNA first? Direct digitization of RF signal Receiver architectures Sub-sampling receiver noise problem Heterodyne receiver
More informationChallenges and Solutions for Removing Fixture Effects in Multi-port Measurements
DesignCon 2008 Challenges and Solutions for Removing Fixture Effects in Multi-port Measurements Robert Schaefer, Agilent Technologies schaefer-public@agilent.com Abstract As data rates continue to rise
More informationPXIe Contents CALIBRATION PROCEDURE
CALIBRATION PROCEDURE PXIe-5632 This document contains the verification and adjustment procedures for the PXIe-5632 Vector Network Analyzer. Refer to ni.com/calibration for more information about calibration
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION TECHNOLOGY Y-Junction circulator PORT 1 PORT 2 PORT 3 FIG. 1 The Y-junction circulator uses spinel ferrites or garnet ferrites in the presence of a magnetic bias field, to provide
More informationAdvanced Test Equipment Rentals ATEC (2832) Agilent 8510 System Solutions
E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent 8510 System Solutions Your bridge to the future Application guide The guide below shows Agilent Technologies
More informationFast and Accurate Simultaneous Characterization of Signal Generator Source Match and Absolute Power Using X-Parameters.
Fast and Accurate Simultaneous Characterization of Signal Generator Source Match and Absolute Power Using X-Parameters. April 15, 2015 Istanbul, Turkey R&D Principal Engineer, Component Test Division Keysight
More informationHot S 22 and Hot K-factor Measurements
Application Note Hot S 22 and Hot K-factor Measurements Scorpion db S Parameter Smith Chart.5 2 1 Normal S 22.2 Normal S 22 5 0 Hot S 22 Hot S 22 -.2-5 875 MHz 975 MHz -.5-2 To Receiver -.1 DUT Main Drive
More informationDemo / Application Guide for DSA815(-TG) / DSA1000 Series
Demo / Application Guide for DSA815(-TG) / DSA1000 Series TX1000 Mobile Phone Frontend Mixer Bandpass Filter PA The schematic above shows a typical front end of a mobile phone. Our TX1000 RF Demo Kit shows
More informationTEST & MEASURING INSTRUMENTS. Analyzer. (4 Ports) 4 Ports
TEST & MEASURING INSTRUMENTS Analyzer (4 Ports) 4 Ports Key Features Frequrncy Range : 100kHz ~ 8GHz, 16 Parameters support (S11 ~ S44) Measurement time per point : 100us per point Wide Output Power Range
More informationAgilent 2-Port and 4-Port PNA-X Network Analyzer. N5241A - 10 MHz to 13.5 GHz N5242A - 10 MHz to 26.5 GHz Data Sheet and Technical Specifications
Agilent 2-Port and 4-Port PNA-X Network Analyzer N5241A - 10 MHz to 13.5 GHz N5242A - 10 MHz to 26.5 GHz Data Sheet and Technical Specifications Documentation Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT
More informationPreliminary Users Manual for the Self Contained Return Loss and Cable Fault Test Set with Amplified Wideband Noise Source Copyright 2001 Bryan K.
Preliminary Users Manual for the Self Contained Return Loss and Cable Fault Test Set with Amplified Wideband Noise Source Copyright 2001 Bryan K. Blackburn Self Contained Test Set Test Port Regulated 12
More informationPLANAR S5048 and TR5048
PLANAR S5048 and TR5048 Vector Network Analyzers KEY FEATURES Frequency range: 20 khz 4.8 GHz COM/DCOM compatible for LabView Measured parameters: and automation programming S11, S12, S21, S22 (S5048)
More informationPulsed VNA Measurements:
Pulsed VNA Measurements: The Need to Null! January 21, 2004 presented by: Loren Betts Copyright 2004 Agilent Technologies, Inc. Agenda Pulsed RF Devices Pulsed Signal Domains VNA Spectral Nulling Measurement
More informationIntroduction to VNA Basics PRIMER
The Vector network analyzer or VNA is an important test instrument that has helped make countless modern wireless technologies possible. Today, VNAs are used in a wide range of RF and high frequency applications.
More informationVector Network Analyzers T - Series
Datasheet Vector Network Analyzers T - Series Wide dynamic range 130 db typ. Low noise level < -120 dbm Low trace noise 1 mdb rms High measurement speed 125ms/point High effective directivity > 45 db Remote
More informationAbstract: Stringent system specifications impose tough performance requirements on the RF and microwave cables used in aerospace and defense
1 Abstract: Stringent system specifications impose tough performance requirements on the RF and microwave cables used in aerospace and defense communication systems. With typical tools, it can be very
More informationWafer-Level Calibration & Verification up to 750 GHz. Choon Beng Sia, Ph.D. Mobile:
Wafer-Level Calibration & Verification up to 750 GHz Choon Beng Sia, Ph.D. Email: Choonbeng.sia@cmicro.com Mobile: +65 8186 7090 2016 Outline LRRM vs SOLT Calibration Verification Over-temperature RF calibration
More informationUnderstanding Low Phase Noise Signals. Presented by: Riadh Said Agilent Technologies, Inc.
Understanding Low Phase Noise Signals Presented by: Riadh Said Agilent Technologies, Inc. Introduction Instabilities in the frequency or phase of a signal are caused by a number of different effects. Each
More informationUsing Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024
Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 1 Suwanee, GA 324 ABSTRACT Conventional antenna measurement systems use a multiplexer or
More informationUnderstanding Mixers Terms Defined, and Measuring Performance
Understanding Mixers Terms Defined, and Measuring Performance Mixer Terms Defined Statistical Processing Applied to Mixers Today's stringent demands for precise electronic systems place a heavy burden
More informationAgilent PNA Microwave Network Analyzers
Agilent PNA Microwave Network Analyzers Application Note 1408-3 Improving Measurement and Calibration Accuracy using the Frequency Converter Application Table of Contents Introduction................................................................2
More informationCircuit Characterization with the Agilent 8714 VNA
Circuit Characterization with the Agilent 8714 VNA By: Larry Dunleavy Wireless and Microwave Instruments University of South Florida Objectives 1) To examine the concepts of reflection, phase shift, attenuation,
More informationEE290C - Spring 2004 Advanced Topics in Circuit Design
EE290C - Spring 2004 Advanced Topics in Circuit Design Lecture #3 Measurements with VNA and TDR Ben Chia Tu-Th 4 5:30pm 531 Cory Agenda Relationships between time domain and frequency domain TDR Time Domain
More informationSHF Communication Technologies AG
SHF Communication Technologies AG Wilhelm-von-Siemens-Str. 23 Aufgang D 2277 Berlin Marienfelde Germany Phone ++49 30 / 772 05 0 Fax ++49 30 / 753 0 78 E-Mail: sales@shf.biz Web: http://www.shf.biz Tutorial
More informationKeysight Technologies Testing Amplifiers and Active Devices with the 8510C Network Analyzer
Keysight Technologies Testing Amplifiers and Active Devices with the 8510C Network Analyzer Technical Overview Discontinued Product Information For Support Reference Only Information herein, may refer
More informationRADIO RECEIVERS ECE 3103 WIRELESS COMMUNICATION SYSTEMS
RADIO RECEIVERS ECE 3103 WIRELESS COMMUNICATION SYSTEMS FUNCTIONS OF A RADIO RECEIVER The main functions of a radio receiver are: 1. To intercept the RF signal by using the receiver antenna 2. Select the
More informationMS4622A/B/D, MS4623A/B/D, MS4624A/B/D 10 MHz to 3 GHz 10 MHz to 6 GHz 10 MHz to 9 GHz
VECTOR NETWORK MEASUREMENT SYSTEMS (VNMS) MS4622A/B/D, MS4623A/B/D, MS4624A/B/D 10 MHz to 3 GHz 10 MHz to 6 GHz 10 MHz to 9 GHz Ethernet / GPIB Innovative Manufacturing Solutions for Measuring S-Parameters,
More informationPXIe Contents CALIBRATION PROCEDURE. Reconfigurable 6 GHz RF Vector Signal Transceiver with 200 MHz Bandwidth
IBRATION PROCEDURE PXIe-5646 Reconfigurable 6 GHz Vector Signal Transceiver with 200 MHz Bandwidth This document contains the verification and adjustment procedures for the PXIe-5646 vector signal transceiver.
More informationMWA REVB LNA Measurements
1 MWA REVB LNA Measurements Hamdi Mani, Judd Bowman Abstract The MWA LNA (REVB) was measured on the Low Frequency Radio astronomy Lab using state of the art test equipment. S-parameters of the amplifier
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationCompact Series: S5048 & TR5048 Vector Network Analyzers KEY FEATURES
Compact Series: S5048 & TR5048 Vector Network Analyzers KEY FEATURES Frequency range: 20 khz - 4.8 GHz Measured parameters: S11, S12, S21, S22 (S5048) S11, S21 (TR5048) Wide output power adjustment range:
More informationAgilent Network Analyzer Selection Guide
Agilent Network Analyzer Selection Guide Please note: This document does not contain Agilent s most up-to-date network analyzer portfolio. This document is available for reference only for customers using
More information