1 1 CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

2 CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL CDN 117 / 117-M CDN 118 / 118-M Signal & data line coupling networks

3 CONTENT 1 General Safety Safety measures Installation Test execution 8 2 Functional description CDN CDN Test setups Connections Using CDN 117 for unshielded interconnection lines Test setup for unshielded unsymmetrically operated lines with 1.2 / 50 µs pulse Using CDN 118-T4 for two or four lines testing Using CDN 118-EXT-1 for eight lines testing 17 4 Technical specifications Environmental conditions Coupling assembly check list 21 5 Maintenance Warranty 23 6 Addresses 24

4

5 1 GENERAL 5 The CDN 117 and CDN 118 coupling - decoupling networks provide a means for injecting standards-compliant surge pulses into signal and datalines, as well as telecom lines. These networks are used in combination with surge generators. Tests can be performed on equipment, assemblies and installations while they are in operation. These tests and their required coupling methods are prescribed in various test standards (e.g. IEC / EN , IEC / EN ). Specifications and recommendations regarding the execution of the tests, and their severity, the permissible reaction by the equipment under test (EUT), etc. can be found in the relevant standards. The CDN 117 with the suffix -M are shipped with a pair of cables that fit Teseq s NSG 3000 family generator or Modula. CDN 118-T4 and CDN 118-EXT-1 are shipped with cables for Teseq s NSG 3000 family generator or Modula. Cables for other generators are available as option. 1.1 Safety The CDN 117 and CDN 118 coupling - decoupling networks are designed for operation with high voltage generators, which contain high energy levels. Incorrect or careless operation can be lethal! The following safety measures must be strictly and responsibly observed at all times. Users must also comply with all safety advice that is provided with generators that are used with the CDN 117 and CDN 118.

6 6 Neither Teseq AG, Luterbach, Switzerland nor its associated sales organizations accept any responsibility for personal injury or for any material or consequential damage resulting from negligent operation of this equipment. These instruments have been designed in conformity with the relevant safety regulations and provide all the necessary requirements for safe and reliable operation. 1.2 Safety measures These operating instructions form an integral part of the equipment and must be carefully studied before putting the equipment into operation and must be available to the user at all times. WARNING - The equipment must only be used by trained personnel. Personnel fitted with a heart pacemaker must neither operate the equipment nor remain in the test vicinity when the generator is in operation. These instruments are not designed for use in an explosive atmosphere. The test equipment is to be set up in conformity with the relevant safety standards (e.g. VDE 104). The coupling network housing must be properly grounded (earthed). To ensure safe operation, only approved accessories, plugs, adapters, etc. are to be used. The setup must offer insulation protection against voltage which is at least equal to the pulse voltage. The pulse voltage must not be able to find its way to ungrounded metallic objects even if the EUT is faulty or fails. CDN 117 / 117-M CDN 118 / 118-M Signal & data line coupling networks

7 Depending on the type of EUT and especially on its cabling, a considerable amount of interference can be radiated which could affect nearby systems and radio communication. These environmental interference effects to be controlled by the user through the use of suitable measures such as a Faraday cage, shielded cable runs, etc Installation Since the CDN 117 and CDN 118 do not have their own power supplies, they have not been assigned a protection class. However, they are typically operated according to protection class 1 in view of their electrical connection to pulse generators and the metallic parts of their casing. Local installation regulations must be respected to ensure the safe flow of leakage currents. WARNING - Operation without a ground (protective earth) connection is forbidden! Operate the equipment only in dry surroundings. Any condensation that occurs must be allowed to evaporate before putting the equipment into operation. Do not exceed the permissible ambient temperature, humidity or altitude. Ensure that a reliable return path for the interference current is provided between the EUT and the generator. The reference ground plane and the ground connections to the instruments that are described in the relevant test standard will serve this purpose well. These instruments should be opened only by a qualified specialist if specifically instructed to do so in the operating manual.

8 8 1.4 Test execution The test area must be organized so that no unauthorized persons have access during execution of a test. If a safety contact (interlock) is used as a means of access control to the test area (e.g. Faraday cage), then an additional contact in series with any hazardous voltages or currents is necessary to provide protection for parts of the EUT that are in danger of being touched. EUTs, together with their accessories and cables, are to be considered live during a test. The test generator must be stopped and the EUT supply interrupted before any work can be performed on the EUT. This can often be achieved by opening the interlock circuit, depending on the type of generator in use. The EUT is to be tested only in a protective cage or under a hood which provides protection against electric shock and all manner of other dangers pertaining to the particular EUT. The safety instructions for all instruments and associated equipment in the test setup are to be observed. The configuration of the test setup is to be strictly in compliance with the methods described in the relevant standard to ensure that the test is executed in a compliant manner. Note: Please use a NSG 3000 series generator with Ed.2 Surge module in combination with a CDN 117 / 118 for IEC :Ed.2 testing and a NSG 3000 series generator with Ed.3 Surge module in combination with a CDN 117 / 118 for IEC :Ed.3 testing. CDN 117 / 117-M CDN 118 / 118-M Signal & data line coupling networks

9 2 FUNCTIONAL DESCRIPTION 9 The CDN 117 and CDN 118 coupling - decoupling networks, together with their accessories, provide a means to inject standardized surge pulses into signal, data and / or telecom lines. These coupling networks can be used in situations where the inputs and outputs of mains-free connection lines must be tested for interference immunity. The CDN 117 and 118 are designed to be used in conjunction with a surge pulse generator. They enable tests to be performed on equipment or systems while they are in operation, by eliminating the attenuation of the surge pulse by auxiliary equipment (AE). The AE must usually be protected by surge suppressors against the effects of excessively high residual currents. Relevant tests and coupling methods are described in the test standards IEC / EN , IEC / EN , IEC / EN , etc. 2.1 CDN 117 The versatile CDN 117 can be used on either unscreened (or unshielded), unsymmetrically driven signal lines as well as on unscreened signal and data lines. The network enables symmetric (line to line) and asymmetric (line to ground) coupling of 1.2 / 50 µs hybrid pulses into pairs of conductors. The test pulse is inductively decoupled from the input side of the CDN (AE terminals) so that the surge pulse is coupled as fully as possible to the EUT via the output terminals. The integral 40 Ω series resistors raise the source impedance of the pulse generator to 40 Ω. (Since the 2 Ω output impedance of the generator is a complex quantity, the combined value of the generator plus 40 Ω lies closer to the required value of 40 Ω).

10 10 Several CDN 117s can be arranged in parallel for applications where more than two conductors must be decoupled. A special coupling cable is needed. DC decoupling must be achieved with a coupler type INA 170 or INA 174A. The coupling mode can be changed by relocating the connecting cable from the pulse generator. 1.6 AT 20 mh A 40 Ω A in PE PE out B 1.6 AT 20 mh 40 Ω B Functional schematic of the CDN 117 INA 170 The INA 170 contains a coupling spark gap without a capacitor. The spark gap has a trigger voltage of 90 V. INA 174A The INA 174A contains a 0.5 µf capacitor that can be connected in series with the 40 Ω already incorporated in the coupling network. This type of coupling element is used for capacitive injection into unscreened signal and data lines. CDN 117 / 117-M CDN 118 / 118-M Signal & data line coupling networks

11 2.2 CDN 118 This device is used on unscreened or unshielded, symmetrically driven telecommunication lines. 11 The network enables symmetric (line to line) and asymmetrical (line to ground) coupling of 1.2 / 50 and 10 / 700 µs pulses into pairs of conductors. The test pulse is inductively decoupled from the input side of the CDN (AE terminals) so that surge pulse is coupled as fully as possible to the EUT. A high value decoupling choke is required due to the large voltage-time characteristic of the 10 / 700 µs pulse. The requisite series resistors are arranged in separate boxes so that all required modes can be achieved by proper connection of the INA 370 cable. DC decoupling can be performed by using either the INA 170 coupling device. L1 L1 in L2 A L2 out PE B PE L3 L3 C L4 L4 D Functional schematic of the CDN 118

12 12 3 TEST SETUPS Each test setup should be carefully planned. All the equipment should be securely positioned, and all cables should be securely connected. The safety advice given in Sections 1 and 2 and in the generator manual must be observed. The EUT and the wiring should be handled only when the generator is not active. Various test setups and test methods are possible. The following sections provide examples with more precise details. 3.1 Connections There are two black safety laboratory sockets on the top left of the CDN 117. Both lines (L1 and L2) are marked as input and each is protected by a 1.6 A fuse. These input sockets share a common ground point which is internally and permanently connected to the housing of the coupling network. The signal or data lines from auxiliary equipment or loads, such as sensors, detectors, converters, temperature probes, switching elements, etc., are connected to these line inputs. The output (out), to which the EUT must be connected, is positioned on the right hand side. The EUT could be, a computer, any type of signal amplifier, an evaluation device or a general type of central system controller. The common ground socket is connected to the housing. The pulse connections from the generator are plugged into two of the five high voltage sockets to obtain the required type of coupling. CDN 117 / 117-M CDN 118 / 118-M Signal & data line coupling networks

13 Symmetrical coupling can only be achieved with generators with floating output. The connection of the coupling network to the high (+) and low (-) outputs of the generators are shown in the following diagrams Using CDN 117 for unshielded, unsymmetrical interconnection lines Generator 1.2 / 50 µs pulse Auxilliary equipment Peripherie INA 170 or INA 174A 1.6 AT 20 mh L1 IN CDN 117 L2 1.6 AT 20 mh 40 Ω 40 Ω OUT Equipment under test EUT Prüfling Line to line coupling, line L1 à L2 If the coupling is changed from L2 à L1, then the polarity from the generator can be swapped.

14 14 Generator 1.2 / 50 µs pulse Auxilliary equipment Peripherie INA 170 or INA 174A 1.6 AT 20 mh L1 IN L2 1.6 AT CDN mh 40 Ω 40 Ω OUT Equipment under test EUT Prüfling Line to ground coupling, line L1 à PE Generator 1.2 / 50 µs pulse Auxilliary equipment Peripherie 1.6 AT 20 mh L1 IN 1.6 AT 20 mh L2 INA 170 or INA 174A CDN Ω 40 Ω OUT Equipment under test EUT Prüfling Line to ground coupling, line L2 à PE CDN 117 / 117-M CDN 118 / 118-M Signal & data line coupling networks

15 3.3 Test setup for unshielded symmetrically operated lines with 1.2 / 50 or 10 / 700 µs pulse Using CDN 118-T4 for two or four lines testing INA 185 for 10 / 700 µs INA 175 for 1.2 / 50 µs + - Generator 10 / 700 µs pulse or 1.2 / 50 µs pulse SHO F105 4 x INA 170 Auxilliary equipment L1 L2 in L3 4 x 0.5 AT 4 x 20 mh CDN 118 L1 L2 out L3 Equipment under test EUT Peripherie L4 L4 Prüfling Line to ground coupling with 10 / 700 µs or 1.2 / 50 µs pulse on telecom lines

16 16 INA 185 for 10 / 700 µs INA 175 for 1.2 / 50 µs INA Generator 10 / 700 µs pulse or 1.2 / 50 µs pulse SHO F105 4 x INA 170 Auxilliary equipment L1 L2 in L3 4 x 0.5 AT 4 x 20 mh CDN 118 L1 L2 out L3 Equipment under test EUT Peripherie L4 L4 Prüfling Line to line coupling with 10 / 700 µs or 1.2 / 50 µs pulse on telecom lines (1 line in turn grounded with INA 173). Please note this setup is not supported by IEC Edition 3. EUT with two lines (one pair) The INA 185 (4 x 25 Ω, only 2x 25 Ω in use) is to be used with a 10 / 700 µs pulse. Respectively, the INA 183 (2 x 80 Ω) is to be used with a 1.2 / 50 µs pulse. EUT with four lines (two pairs) The INA 185 (4 x 25 Ω) is to be used with a 10 / 700 µs pulse. Respectively, the INA 175 (4 x 160 Ω) is to be used with a 1.2 / 50 µs pulse. CDN 117 / 117-M CDN 118 / 118-M Signal & data line coupling networks

17 High EUT Power Output Surge Output Low Burst Output Power on Pulse High voltage active EUT-Power on Error Using CDN 118-T4 with CDN 118-EXT-1 for eight lines coupling 17 NSG 3000 series with 1.2/50 µs surge pulse SURGE GENERATOR NSG 3040 INA 184 SHO F105, Short circuit connector INA 181 4x 320 Ω INA 181 4x 320 Ω 8x INA 170 8x INA 370 Auxiliary equipment AE 2x CDN 118 Surge input Equipment under test EUT AE port EUT port Insulating (if required) Ground plane Insulating (if required) Line to ground coupling with 1.2 / 50 µs pulse on telecom lines. CDN 118-T4 extended with option CDN 118-EXT-1 for eight lines coupling

18 High EUT Power Output Surge Output Low Burst Output Power on Pulse High voltage active EUT-Power on Error 18 NSG 3000 series with 10/700 µs surge pulse SURGE GENERATOR NSG 3040 INA 184 SHO F105, Short circuit connector INA 185 4x 25 Ω INA 185 4x 25 Ω 8x INA 170 8x INA 370 Auxiliary equipment AE 2x CDN 118 Surge input Equipment under test EUT AE port EUT port Insulating (if required) Ground plane Insulating (if required) Line to ground coupling with 10 / 700 µs pulse on telecom lines. CDN 118-T4 extended with option CDN 118-EXT-1 for eight lines coupling CDN 117 / 117-M CDN 118 / 118-M Signal & data line coupling networks

19 4 TECHNICAL SPECIFICATIONS 19 Type CDN 117 CDN 118 Signal line: Maximum operating voltage AC DC 250 V 250 V 250 V 250 V Maximum operating current 1.5 A 0.5 A Ohmic resistance per path < 2.5 Ω 3 Ω Decoupling chokes 1 khz 20 mh + / - 20% 20 mh + / - 20% Symmetrical stray inductance of a khz Not applicable 50 µh approx. Transmission 3 db BW 800 Hz 250 khz Connectors 4 mm safety banana connectors Integral resistors 2 x 40 Ω / 6 W none Pulse path: 1.2 / 50 µs pulse 6600 V 6600 V line to ground 3000 V line to line 10 / 700 µs pulse Min. generator impedance 1.2 / 50 µs pulse 10 / 700 µs pulse not applicable 2 Ω Not permittled 6600 V line to ground 3000 V line to line 2 Ω 15 Ω Series resistor 2 x 40 Ω, 6 W none Maximum pulse frequency 3 per minute 3 per minute Connectors 5 Fischer type 5 Fischer type Depending on the impedance setting of the pulse generator, some pulse distortion occurs at the coupler spark gap caused by the inductive loading and the voltage drop. The 0.5 / 700 and 100 / 700 µs pulses are treated the same as the 10 / 700 µs pulses.

20 20 INA 170 Spark gap 90 V Maximum pulse voltage Maximum pulse rate Socket Plug Size (W x H x D) in mm Weight 10 / 700 µs pulse 1.2 / 50 µs pulse 6600 V 6600 V 3 per minute 1x Fischer type 103 1x Fischer type x 25 x kg INA 175 Integral resistors 4 x 160 Ω, 6 W Maximum pulse voltage Minimum series impedance Maximum pulse rate Sockets Size (W x H x D) in mm Weight 1.2 / 50 µs pulse 1.2 / 50 µs pulse 6600 V 2 Ω 3 per minute 9x Fischer type x 160 x 90 2 kg INA 181 Integral resistors 4 x 320 Ω, 6 W Maximum pulse voltage Minimum series impedance Maximum pulse rate Sockets Size (W x H x D) in mm Weight 1.2 / 50 µs pulse 1.2 / 50 µs pulse 6600 V 2 Ω 3 per minute 9x Fischer type x 160 x 90 2 kg INA 183 Integral resistors 2 x 80 Ω, 6 W Maximum pulse voltage Minimum series impedance Maximum pulse rate Sockets Size (W x H x D) in mm Weight 1.2 / 50 µs pulse 1.2 / 50 µs pulse 6600 V 2 Ω 3 per minute 5x Fischer type x 160 x 90 2 kg INA 185 Integral resistors 4 x 25 Ω, 10 W Maximum pulse voltage Minimum series impedance Maximum pulse rate Sockets Size (W x H x D) in mm Weight 10 / 700 µs pulse 10 / 700 µs pulse 6600 V 15 Ω 3 per minute 9x Fischer type x 160 x 90 2 kg CDN 117 / 117-M CDN 118 / 118-M Signal & data line coupling networks

21 4.1 Environmental conditions Only intended for indoor applications 21 Ambient temperature Normal utilization Storage and transport C C Relative humidity Nominal working range % reducing linearly above 31 C to 50% at 40 C Condensation Not permissible under operation Altitude Nominal working range Storage and transport < 2200 m < m 4.2 Coupling assembly check list CDN 117 Coupling assembly Set consisting of: 1 ea. CDN ea. INA 170 coupler with spark gap only 1 ea. INA 174A coupler with capacitor 2 ea. INA 371 coax cable, 0.8 m with connectors (Lemo / Fischer) 4 ea. Safety laboratory plugs, black 2 ea. Safety laboratory plugs, yellow / green 1 ea. Operating manual CDN 117 M Coupling assembly As above but instead of 2 pcs INA 371 supplied with 2 pcs INA 6549 coax cable, with Fischer connectors fitting Modula and NSG 30xx generator family.

22 22 CDN 118-T4 Set consisting of: 1 ea. CDN 118 main unit 4 ea. INA 170 coupler with spark gap only 1 ea. INA 173 short-circuit plug (Fischer) 1 ea. INA 175 matching resistor network, 4 x 160 Ω 1 ea. INA 183 matching resistor network, 2 x 80 Ω 1 ea. INA 185 matching resistor network, 4 x 25 Ω 4 ea. INA 370 coax cable, 0.8 m with connectors (Fischer 103 / Fischer 103) 1 ea. INA 6549 coax cable, 2 m with connectors (Fischer 105 / Fischer103) 1 ea. SHO F105 short circuit connector Fischer ea. Safety laboratory plugs, black 2 ea. Safety laboratory plugs, yellow / green 1 ea. Operating manual CDN 118-EXT-1 (option) Set consisting of: 1 ea. CDN 118 main unit 4 ea. INA 170 coupler with spark gap only 2 ea. INA 181 matching resistor network, 4 x 320 Ω 1 ea. INA 185 matching resistor network, 4 x 25 Ω 4 ea. INA 370 coax cable, 0.8 m with connectors (Fischer 103 / Fischer 103) 1 ea. INA 184 Y cable, 1 m with connectors (1x Fischer 105 / 2x Fischer 103) 8 ea. Safety laboratory plugs, black 2 ea. Safety laboratory plugs, yellow / green CDN 117 / 117-M CDN 118 / 118-M Signal & data line coupling networks

23 5 MAINTENANCE 23 No maintenance is necessary. Teseq recommends performing an annual insulation test with a pulse voltage of 6 kv and open EUT outputs. No arcing or internal breakdown should be detectable during the test. 5.1 Warranty Teseq warrants this instrument to be free of defects in materials and workmanship for a period of two years, effective from the date of purchase. During this period, any defective component part will be repaired or replaced free of charge or, if necessary, Teseq will replace the instrument with one of equivalent value. The method of repair / replacement will be at Teseq s sole discretion. Excluded from warranty are damage or consequential damage caused by negligent operation or use as well as the replacement of parts subject to degradation. This warranty is rendered invalid by any attempt to modify or repair the instrument on the part of the customer or a third party. The instrument is to be returned in its original packaging. Teseq can accept no responsibility for damage in transit.

24 Headquarters Teseq AG Sternenhofstrasse Reinach / Switzerland T F China AMETEK Commercial Enterprise (Shanghai) Co., Ltd. Beijing Branch) T teseq.com Japan AMETEK CO., Ltd. Nagoya Office T ametek.co.jp Singapore AMETEK Singapore Pte Ltd. (C/o Teseq Pte Ltd.) T Taiwan Teseq Ltd. T Manufacturer Teseq GmbH Berlin, Germany Landsberger Str. 255 T F Germany AMETEK CTS Germany GmbH T ametek.com Poland AMETEK CTS Germany GmbH T ametek.com Switzerland Teseq AG T UK Teseq Ltd. T teseq.com USA Teseq Inc. T Toll free teseq.com To find your local partner within Teseq s global network, please go to August 2016 Teseq Specifications subject to change without notice. Teseq is an ISOregistered company. Its products are designed and manufactured under the strict quality and environmental requirements of the ISO This document has been carefully checked. However, Teseq does not assume any liability for errors or inaccuracies.

CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL A

CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL A 1 CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL 601-339A CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL Calibration kit for EFT / Burst

More information

Advanced Test Equipment Rentals ATEC (2832) INA A

Advanced Test Equipment Rentals ATEC (2832) INA A Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) 1 INA 703 Magnetic field coil User manual 601-335A INA 703 Magnetic field coil User manual INA 703 Magnetic field coil

More information

MD 200A High voltage differential probe

MD 200A High voltage differential probe 1 MD 200A High voltage differential probe User Manual 601-265B MD 200A High voltage differential probe User Manual MD 200A high voltage differential probe contents 1 Safety terms and symbols 5 2 Safety

More information

MD 103 ESD TargET SET USEr ManUal B

MD 103 ESD TargET SET USEr ManUal B 1 MD 103 ESD Target Set User Manual 601-266B MD 103 ESD Target Set User Manual MD 103 ESD target set contents 1 Safety terms and symbols 5 2 The ESD target set 6 3 Handling of the target set 7 4 Requirements

More information

Coupling / decoupling network (CDN) for screened or coaxial cables

Coupling / decoupling network (CDN) for screened or coaxial cables IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq

More information

TETRIS User's Guide. High Impedance Active Probe DO177-1

TETRIS User's Guide. High Impedance Active Probe DO177-1 TETRIS 1500 High Impedance Active Probe User's Guide DO177-1 TETRIS 1500 Copyright 2010 Ltd. All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

Schlöder GmbH - EMC Test and Measurement Systems Model #

Schlöder GmbH - EMC Test and Measurement Systems Model # Schlöder GmbH - EMC Test and Measurement Systems Model # Product Description IEC / EN 61000-4 - 2 ESD SESD 216 ESD generator 10 kv CON / 16,5 kv AIR acc. to IEC 61000-4-2, 150 pf / 330 ohm SESD 230 ESD

More information

COUPLING DECOUPLING NETWORKS FOR IEC / EN

COUPLING DECOUPLING NETWORKS FOR IEC / EN COUPLING DECOUPLING NETWORKS FOR IEC / EN 60--6 IEC / EN 60--6 specifies the design and performance of a range of coupling / decoupling networks (s). Each is specific to the type of cable and the intended

More information

Coupling/Decoupling Networks (CDN)

Coupling/Decoupling Networks (CDN) Coupling/Decoupling Networks (CDN) For immunity testing according to IEC / EN 61000-4-6 Immunity testing CDNs are the preferred coupling and decoupling devices, for reasons of test reproducibility and

More information

P331-2 set ESD generator (IEC )

P331-2 set ESD generator (IEC ) User manual Probe set set ESD generator (IEC 61000-4-2) Copyright January 2017 LANGER GmbH 2017.01.09 User manual Table of contents: Page 1 ESD generator (IEC 61000-4-2) 3 1.1 Design and function of the

More information

TA MHz oscilloscope probe TA MHz oscilloscope probe

TA MHz oscilloscope probe TA MHz oscilloscope probe TA375 100 MHz oscilloscope probe TA386 200 MHz oscilloscope probe User's Guide X1 X10 TA386 X1/X10 Max. 600 Vp Introduction This passive high-impedance oscilloscope probe is suitable for most oscilloscopes

More information

PHV RO High Voltage Passive Probe. Instruction Manual

PHV RO High Voltage Passive Probe. Instruction Manual PHV 1000-3-RO High Voltage Passive Probe Instruction Manual Copyright 2012 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

V1.3. TBLC08 50mH AC-LISN TBLC08

V1.3. TBLC08 50mH AC-LISN TBLC08 V1.3 TBLC08 The TBLC08 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard. The device is designed

More information

Technical Specification

Technical Specification LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification E-MIG1203CWG revised: 22. June 2003 1 MIG Tester Type MIG1203CWG 1 MIG Tester Type MIG1203CWG 1 1.1 Introduction 1 2 General 2

More information

Original operating instructions Fail-safe inductive sensor GG507S

Original operating instructions Fail-safe inductive sensor GG507S Original operating instructions Fail-safe inductive sensor GG507S 80236827 / 00 09 / 2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related

More information

Voltage Transient Emission Test

Voltage Transient Emission Test Manual For Operation AN 200 Series Voltage Transient Emission Test AN 200 AN 200B The AN 200 is used to evaluate automotive electrical and electronic components for conducted emissions of transients along

More information

Surge Coupling Decoupling Network (S-CDN) Considerations

Surge Coupling Decoupling Network (S-CDN) Considerations Surge Coupling Decoupling Network (S-CDN) Considerations Introduction Surge Coupling-Decoupling Networks (SCDN) are used to couple the surge specified in IEC 61000-4-5 onto active telecom lines to determine

More information

Combination Wave Test System

Combination Wave Test System Immunity Tests Combination Wave Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................

More information

Bulk Current Injection Probe Test Procedure

Bulk Current Injection Probe Test Procedure Bulk Current Injection Probe Test Procedure 1 TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 TEST METHODS 6 SAFETY 8 FIGURES 9 FORMULAS 12 MAINTENANCE 13 WARRANTY 14 2 INTRODUCTION CURRENT PROBE

More information

Coupling/Decoupling Networks (CDN)

Coupling/Decoupling Networks (CDN) Coupling/Decoupling Networks (CDN) For immunity testing according to IEC / EN 61000-4-6 Immunity testing CDNs are the preferred coupling and decoupling devices, for reasons of test reproducibility and

More information

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) 3-349-878-03 1/3.16 Opening the Instrument / Repairs The instrument may only be opened by authorized, trained personnel

More information

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

MHz FUNCTION GENERATOR INSTRUCTION MANUAL 72-6859 20MHz FUNCTION GENERATOR INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 EMC 5 Safety 4 Installation 5 Operation 7 Maintenance 8 www.tenma.com 1 Introduction This instrument

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Digital Multimeter E 1018832 Instruction sheet 12/16 SD/UD 1 probe 1a Finger guards 2 Measurement socket 10 A for current measurement in 10-A (positive) 3 Measurement socket COM (negative)

More information

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor. Introduction to EMC Schurter has over 75 years experience in the electronics and electrical industries, developing and manufacturing components that ensure a clean and safe supply of power. Schurter provides

More information

NSG 3025 BurSt GeNerator user manual D

NSG 3025 BurSt GeNerator user manual D 1 NSG 3025 Burst generator User manual 601-210D NSG 3025 Burst generator User Manual NSG 3025 Burst Generator Contents 1 Safety advice 7 1.1 General 7 1.2 Installation guidlines 8 1.3 Test execution 9

More information

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz USER manual Falco Systems WMA-100 High Voltage Amplifier DC - 500kHz Falco Systems WMA-100, High Voltage Amplifier DC - 500kHz High voltage: 20x amplification up to +175V and -175V output voltage with

More information

EMC Data Sheet CSD100 Model size 4 to 6. Variable Speed AC drive for permanent magnet motors

EMC Data Sheet CSD100 Model size 4 to 6. Variable Speed AC drive for permanent magnet motors EMC Data Sheet CSD100 Model size 4 to 6 Variable Speed AC drive for permanent magnet motors Safety Warnings A Warning contains information which is essential for avoiding a safety hazard. A Caution contains

More information

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed 17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:

More information

TK 100 Probe Calibrator. Instruction Manual

TK 100 Probe Calibrator. Instruction Manual TK 100 Probe Calibrator Instruction Manual Copyright 2013 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are subject

More information

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN out < +0 out < +0 ch. < +0 ch. < +0 ch. < +7 ch. < +0 ch. < +0 ch. < +7 LL LL nd nd 0 8... Test setup calibration with a CDN The calibration setup always refers to the type of CDN. The CDN user manuals

More information

374/375/376 Clamp Meter

374/375/376 Clamp Meter 374/375/376 Clamp Meter Users Manual PN 3608883 July 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks

More information

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2. TA043 100 MHz x10/x100 Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2 031 CAT III, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING

More information

netzerotools.com 374/375/376 Users Manual Clamp Meter

netzerotools.com 374/375/376 Users Manual Clamp Meter 374/375/376 Clamp Meter Users Manual Fluke 376 True RMS AC DC Clamp Meter Fluke 374 True RMS AC / DC Clamp Meter Fluke 373 True RMS AC Clamp Meter Fluke 375 True RMS AC / DC Clamp Meter LIMITED WARRANTY

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

CNV 504 / 508 T-SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

CNV 504 / 508 T-SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES) CNV 504 / 508 T-SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION (COMMUNICATION ) DO BADAŃ ZGODNIE Z... > EN 61000-4-5 > IEC 61000-4-5 > ITU-T K.44 CNV 504 / 508 T-SERIES -

More information

HIGH VOLTAGE PHASE COMPARATORS

HIGH VOLTAGE PHASE COMPARATORS USER'S MANUAL for HIGH VOLTAGE PHASE COMPARATORS PC Series Double Poles Model System Voltage Full Scale MT6k 6.6kV 8kV MT11k 11kV 12kV MT22k 22kV 24kV MT33k 33kV 36kV MT44k 44kV 48kV Exceeds VDE681-5 /

More information

Installation Instructions RF-identification system Read/write head ANT513

Installation Instructions RF-identification system Read/write head ANT513 Installation Instructions RF-identification system Read/write head ANT513 80262946 / 00 04 / 2017 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 2.1 General...4 2.2 Radio

More information

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual Dawson DDM181 Pocket-Size Autorange Digital Meter User s Manual 1 Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Important Safety Information...

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent Technical Requirements for Resistibility of Telecommunications Equipment to Overvoltage and Overcurrent TR NO.189001 Edition 2.1 1st, April, 2015 Nippon Telegraph and Telephone Corporation Notice This

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc. User s Guide RP5600 Passive Probe July 2010 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered trademark

More information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to

More information

R-X SERIES. Decade Resistor

R-X SERIES. Decade Resistor PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT R-X SERIES Decade Resistor User and Service Manual Effectivity: Serial Numbers beginning with P2 RX im/august, 2002 Copyright 2002 IET Labs, Inc. IET LABS,

More information

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system

More information

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage

More information

QUINT-PS/ 1AC/24DC/20

QUINT-PS/ 1AC/24DC/20 Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system

More information

Instruction Manual AVTM670600a for Resonating Inductor Catalog No High-Voltage Equipment Read the entire manual before operating.

Instruction Manual AVTM670600a for Resonating Inductor Catalog No High-Voltage Equipment Read the entire manual before operating. AVTM670600a Rev. B December 2002 Instruction Manual AVTM670600a for Resonating Inductor Catalog No. 670600 High-Voltage Equipment Read the entire manual before operating. Aparato de Alto Voltaje Antes

More information

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with

More information

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs Test & Measurement Data Sheet 03.00 R&S ENV216 Two-Line V-Network At a glance The R&S ENV216 two-line V-network meets

More information

79/26 Series III Multimeter

79/26 Series III Multimeter 79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position

More information

EMC Data Sheet Unidrive-M Model size 3. Variable Speed AC drive for induction and permanent magnet motors

EMC Data Sheet Unidrive-M Model size 3. Variable Speed AC drive for induction and permanent magnet motors EMC Data Sheet Unidrive-M Model size 3 Variable Speed AC drive for induction and permanent magnet motors Safety Warnings A Warning contains information which is essential for avoiding a safety hazard.

More information

DMM8900 SERIES USERS MANUAL

DMM8900 SERIES USERS MANUAL DMM8900 SERIES USERS MANUAL WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of one year. Any instrument found defective within one year from the delivery

More information

Operator s Manual. PP022 Passive Probe

Operator s Manual. PP022 Passive Probe Operator s Manual PP022 Passive Probe 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000, Fax: (845) 578 5985 teledynelecroy.com PP022 Passive Probe Instruction Manual 2017 Teledyne

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Antenna Splitter ASA 1. Instruction manual

Antenna Splitter ASA 1. Instruction manual Antenna Splitter ASA 1 Instruction manual Contents Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Combination possibilities of ASA 1/ASA 1-1G8... 5 Delivery includes...

More information

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

EMC Seminar Series All about EMC Testing and Measurement Seminar 1 EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Introduction to EMC Conducted Immunity Jeffrey Tsang Organized by : Department of Electronic Engineering 1 Basic Immunity Standards: IEC

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 200-S ULTRASTAB I PM = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT. HRRS 5kV AND 10kV SERIES. High Resistance, 5kV and 10kV Decade Substituter User and Service Manual

PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT. HRRS 5kV AND 10kV SERIES. High Resistance, 5kV and 10kV Decade Substituter User and Service Manual PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT HRRS 5kV AND 10kV SERIES High Resistance, 5kV and 10kV Decade Substituter User and Service Manual Copyright 2013 IET Labs, Inc. Visit www.ietlabs.com for

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline counter terminal, version for extreme conditions, 1 counter input, 1 control input, 1 output, 24 V DC, 500 ma Data sheet 106148_en_03 PHOENIX CONTACT 2015-11-04 1 Description The terminal is designed

More information

AC 3. Active Antenna Combiner. Instruction manual

AC 3. Active Antenna Combiner. Instruction manual AC 3 Active Antenna Combiner Instruction manual Contents Contents Important safety instructions... 2 The AC 3 active transmitter combiner... 4 Delivery includes... 4 Operating controls... 5 Block diagram...

More information

Learning Material Ver 1.1

Learning Material Ver 1.1 SCR Triggering Circuits Scientech 2702 Learning Material Ver 1.1 An ISO 9001:2008 company Scientech Technologies Pvt. Ltd. 94, Electronic Complex, Pardesipura, Indore - 452 010 India, + 91-731 4211100,

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual

More information

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Radio Frequency Lighting Devices (RFLDs)

Radio Frequency Lighting Devices (RFLDs) Issue 2 February 2007 Spectrum Management and Telecommunications Interference-Causing Equipment Standard Radio Frequency Lighting Devices (RFLDs) Aussi disponible en français NMB-005 Contents 1. General...

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 700-SB ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features ± 10 V voltage output

More information

7P Series - Surge Protection Device (SPD) Features 7P P P

7P Series - Surge Protection Device (SPD) Features 7P P P Features 7P.09.1.255.0100 7P.01.8.260.1025 7P.02.8.260.1025 SPD Type 1+2 Surge arrester range - single phase system / three phase system Surge arresters suitable in low-voltage applications in order to

More information

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing EMC PARTNER DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing This document has been optimized for electronic media Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management

More information

Transient Protection

Transient Protection IEC61000-4-2 (ESD) IEC61000-4-4 (Burst) IEC61000-4-5 (Surge) Transient Protection Thomas Kugelstadt October 2010 1 Industrial networks must operate reliably in harsh environments. Electrical over-stress

More information

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan 4322705.50 EMC Test report for Plug-in adaptor Models PM1W-IT, PM1WU2-IT, PM1W-GR, PM1W-SP, PM1W-RS, PM1WB-RS, PM1WU2-GR, PM1WU2-SP, PM1WU2-RS, PM1WBU2-RS, PM1W-UK, PM1WU2-UK, PM1W-FR, PM1WU2-FR Guangzhou,

More information

Emerging Standards for EMC Emissions & Immunity

Emerging Standards for EMC Emissions & Immunity Emerging Standards for EMC Emissions & Immunity Requirements for Industrial, Scientific, Medical & Information Technology Equipment CE Marking requirements are the path to increased market access Powerful

More information

Operator s Manual. PP016 Passive Probe

Operator s Manual. PP016 Passive Probe Operator s Manual PP016 Passive Probe 2017 Teledyne LeCroy, Inc. All rights reserved. Unauthorized duplication of Teledyne LeCroy documentation materials is strictly prohibited. Customers are permitted

More information

R&S ZNC Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5. Content Monitoring relay pluggable 1-phase current monitoring relay... 5.2 1-phase direct-current voltage monitoring relay... 5.6 1-phase voltage monitoring relay... 5.10 3-phase voltage monitoring relay...

More information

Model 229 Series 2 Leakage Current Tester OPERATOR S MANUAL

Model 229 Series 2 Leakage Current Tester OPERATOR S MANUAL Model 229 Series 2 Leakage Current Tester OPERATOR S MANUAL SIMPSON ELECTRIC COMPANY 52 Simpson Avenue Lac du Flambeau, WI 54538-99 (715) 588-3311 FAX (715) 588-3326 Printed in U.S.A. Part No. 5-11575

More information

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted

More information

Warning, refer to accompanying documents.

Warning, refer to accompanying documents. About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument

More information

CS114 + CS115 + CS116

CS114 + CS115 + CS116 System description Test Setup for MIL-STD-461 D, E&F CS114 + CS115 + CS116 1. MONTENA EMC... 2 1.1 PRODUCTS... 3 1.2 TURN KEY MIL STD 461 TEST INSTALLATIONS... 3 2. TEST SETUP DESCRIPTION... 4 2.1 TEST

More information

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER: A V T E C H E L E C T R O S Y S T E M S L T D. N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P.O. BOX 265 OGDENSBURG, NY U.S.A. 13669-0265 TEL: 888-670-8729 (USA & Canada)

More information

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017 Ref: ART-B22-D70, ART-B22-D125, ART-B22-D175, ART-B22-D300 Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

CSM_G7S-_-E_DS_E_7_1

CSM_G7S-_-E_DS_E_7_1 Relays with Forcibly Guided Contacts G7S-@-E CSM_G7S-_-E_DS_E_7_ Relays with Forcibly Guided Contacts and High Switching Capacity of A Relays with forcibly guided contacts (EN525 Class A, certified by

More information

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Giga-tronics GT-1050A Microwave Power Amplifier GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier Operation Manual

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i310s AC/DC Current Clamp Instruction Sheet Introduction The i310s Current Clamp ( Clamp ) has been designed for use with oscilloscopes and digital multimeters for accurate nonintrusive measurement of

More information

HEMP Filter Design To Meet MIL -STD PCI Test Requirements

HEMP Filter Design To Meet MIL -STD PCI Test Requirements HEMP Filter Design To Meet MIL -STD-188-125 PCI Test Requirements Author : Antoni Jan Nalborczyk CEng MIET, Technical Director, MPE Limited, Liverpool, UK 12/06/2010 ABSTRACT Philosophies for the best

More information

374/375/376 Clamp Meter. Users Manual

374/375/376 Clamp Meter. Users Manual 374/375/376 Clamp Meter Users Manual Introduction XWWarning Read "Safety Information" before you use the Meter. The Fluke 374, 375, and 376 (the Meter) measure true-rms ac current and voltage, dc current

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

High Frequency Sinewave Guardian TM Filter

High Frequency Sinewave Guardian TM Filter High Frequency Sinewave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL FORM: SHF-TRM-E REL. April 2015 REV. 001 2015 MTE Corporation Caution Prior to start up; confirm the drive operation mode

More information

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

SPAC265-8W. AC-DC power supply module. Features. Description. Applications AC-DC power supply module Datasheet production data Features Open frame switch mode power supply European input voltage range Single output 5 V, 8 W peak power, 4 W continuous operating mode EMC compliance

More information

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany Technical manual Microstep driver NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D-85652 Landsham near Munich, Germany Tel. +49 (0)89-900 686-0 Fax +49 (0)89-900 686-50 info@nanotec.de Editorial Editorial

More information

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO AMPROBE 1 Congratulations! You are now the owner of an AMPROBE Instrument. It has been quality crafted according to quality standards and contains quality components

More information

QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY BUS SUPPLY QPI CONVERTER

QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY BUS SUPPLY QPI CONVERTER QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY EMI control is a complex design task that is highly dependent on many design elements. Like passive filters, active filters for conducted noise require careful

More information

ELECTRICAL SAFETY TESTERS. Wings for Your Projects. APPLICATION NOTE

ELECTRICAL SAFETY TESTERS. Wings for Your Projects. APPLICATION NOTE APPLICATION NOTE ELECTRICAL SAFETY TESTERS Wings for Your Projects. Four Principal Tests for Evaluating the Safety of Electrical and Electronic Products TOS SERIES ELECTRICAL SAFETY TESTER TOS SERIES SELECTION

More information