1 C TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY Integrated signal generator to G power meter inputs to G Integrated class A power amplifier module for different applications: W, 0 to 0 ; 0 W, 0 to 00 ; W, to G; 0 W, 0 to 00 (>0 W, to 0 ); 80 W, 0 to 0 Multiple EUT monitoring options,7 TFT color display Internal, menu-based control software Basic remote control software and report generator included Optically decoupled remote control Whisper mode The is a multi-functional device for carrying out EMC immunity tests to accompany development and conformity testing in accordance to IEC / EN 000--, Namur and several automotive BCI standards. Anyone who spends a considerable amount of time on test level setting, connecting EUT monitoring or writing test reports can now carry out immunity testing in a much more efficient manner with the th generation of. Its modular set-up using internal or external amplifiers enables a large variety of applications. The powerful and easy to use firmware makes the independent from an external PC and control software, however it can also be remote controlled for system operation. A state-of-the-art data transfer of test and measurement data for documentation is provided by stick to be plugged into the front panel. External access to signal generator output and power amplifier input and output power meter inputs.7 color display, easy to use firmware Hard keys for important functions Standards: IEC / EN IEC / EN IEC / EN IEC / EN IEC ISO - MIL-STD- CS Ford FMC78 GM GMW07 Nissan 800NDS Peugot PSA B 70 Renault And others User port for TTL inputs and TTL outputs and supply voltages for individual monitoring and control applications Analog, digital and optical monitoring inputs for extensive EUT monitoring options Remote control via optical RS, RS, LAN or x, 0 reference output, Trigger input, external modulation input

2 C Selection guide for the power amplifier Immunity testing Immunity testing Automotive BCI Automotive BCI testing MIL-STD- RTCA IEC / EN ) Namur ) testing ) Ford FMC78 ) G DO-0G 0 to 0 0 to 80 ISO -: 0 CS ) CS Test ) Product amplifier nominal power amplifier frequency range CDN EM clamp Current injection probe CDN EM clamp Current injection probe Substitution Closed loop with k = Substitution Closed loop with k = Substitution Closed loop with k = C-0 - * * * * * * * * * * * * C-0 + external amp 0 W (>0 W at ) 0 ( ) to ma > Level I 00 ma > Level I dbµa Level 0 dbµa Level dbµa Level 00 ma Level: M, R, S, T, W C-0 + external amp 0 W (>0 W at ) 0 ( ) to ma > Level I 00 ma > Level I dbµa Level 0 dbµa Level dbµa Level 00 ma Level: M, O, R, S, T, W, Y C- W 0 to 0 * * * * * * * * * C-0 0 W 0 to 0 ma 0 ma 08 dbµa 0 dbµa 08 dbµa 0 ma 00 > Level I Level III Level Level Level Level: M, R, S, T C- W to G 7 0 ma 0 ma 08 dbµa 0 dbµa 08 dbµa 0 ma > Level I Level III Level Level Level Level: M, R, S, T C-0 ) 0 W 0 ( ) 8 00 ma 0 ma 0 dbµa 0 dbµa 0 dbµa 0 ma (>0 W at ) to 00 > Level I Level III Level Level Level Level: M, R, S, T, W C W 0 to * * * * * * * * * All level calculated in relation to the standard requirements with typical values of the coupling device. ) Calculated with db attenuator, 0. db cable loss and AM with 80% modulation depth. Calculated with typical insertion loss of Teseq CDN with 0. db, Teseq EM clamp KEMZ 80A with. db (range 0 to 0 ) or 7. db (range 0 to 80 ) and Teseq CIP A with db (range 0 to 0 ) or. db (range 0 to 80 ). ) Calculated with highest test level in the frequency range and related typical insertion loss of the BCI probe Teseq CIP A. ) The C-0 measures the reverse power also with selected internal power amplifier ( channel power meter and bidirectional coupler) as may required by the BCI standard. *) Requires external directional coupler and external power amplifier for the frequency range and test level.

3 C Technical specifications Generator Frequency range: to G Resolution: Reference frequency: 0 Aging: ppm Level Level range: -0 to +0 Resolution: 0. db Settling time: 0 ms Amplitude modulation Modulation depth: 0 to 00% Modulation frequency range: to 0 Frequency resolution: Pulse modulation (possible to interlace up to three pulse modulations) Rise / fall time (0% / 0%): < µs Modulation frequency range: 0.0 to Frequency resolution: 0.0 Duty cycle: 0.% to 00% External modulation Delay time: < µs / 80 Period: min. 0 µs Pulse width: min. 0 µs Frequency range: Linear measurement range channel : channel,: Max. input / no damage channel -: Noise level: Input return loss: Connector: Accuracy 0 to 0 C: to G - to +7 (C-0:-0 to +7 ) - to > db below the measurement range >0 db (below 00 ), >7 db (00 to G) BNC socket, 0 Ω <0. db, typ. <0. db

4 C amplifier Nominal output power: W 0 W (preliminary) W 0 W (preliminary) 80 W Frequency range: 0 to 0 0 to 00 to G 0 ( ) to 00 0 to 0 Type: single band, class A single band, class A single band, class A single band, class A single band, class A Input / output impedance (nominal): 0 Ω 0 Ω 0 Ω 0 Ω 0 Ω Input return loss (minimum): 0 db 0 db 0 db 0 db 0 db Output return loss (nominal): min.. db min.. db min.. db min.. db min.. db Output return loss without damage: 0 db 0 db 0 db 0 db 0 db Gain (minimum): 8 db 0 to 0 0 db 0 to 00 7 db 0 db to 0 db 0 to 00 db 0 db Gain flatness (maximum): + / - db + / - db + / - db + / - db + / - db Saturated output power (minimum):. 0 to 0 0 to 00. < 00. > 00. to 0 0 to 00 Linear output power (minimum): 0 to 0 0 to 00 < 00. > 00 to to Input power without damage (maximum): Harmonic distortion at linear output power (typical): < -7 dbc < -0 dbc < -0 dbc < -8 dbc < -0 dbc

5 C amplifier of C- in in Watts Frequency in amplifier of C-0 (preliminary data) in in Watts Frequency in amplifier of C- Legend typical saturated power typical linear power specification saturated power specification linear power in in Watts Frequency in

6 C amplifier of C-0 (preliminary data) in in Watts Frequency in amplifier of C-80 in in Watts Frequency in Legend typical saturated power typical linear power specification saturated power specification linear power

7 C Test and measurement routines Firmware: Generator mode Sweep: Modulation: Others: Frequency sweep, level sweep AM, AM PC (peak conservation), pulse modulation and external Free parameter setting from to G, high power mode using power amplifier Firmware: Main generator menu Firmware: Immunity mode Firmware: Immunity test setup Firmware: Calibration result Level: Test methods IEC 000--: Test methods BCI: Sweep: Modulation: EUT monitoring: Calibration: EUT threshold search: Store and recall: Component check: Amplifier saturation check: Additional features: start and stop level or sections can be defined, max test levels depending on power amplifier or for IEC limited to 0 EMF, for BCI tests levels in units ma or dbµa CDN, EM clamp, current clamp and direct injection, clamp injection with test level control using monitoring probe substitution method with optional use of the monitoring probe, closed loop method with power limitation (factor adjustable) frequency or section sweep with linear, steps per decade or percentage increase AM, AM PC (peak conservation), pulse modulation, external or mixed (e.g. AM internal modulated with PM external) Individual configuration of the port s functionality, display of events during the test, in the result file and in the test report Test set-up and monitoring probe calibration, display, store and recall function of calibration files (limitation of file numbers only by the disk space, typical >0 files) Manual search by changing frequency or stress level Store and recall function of test configurations, calibration results and test results (number of files is only limited by the disk space, typical >0 files), supports sticks Quick check of system components, e.g. cable, attenuator max. db / db / 8 db attenuation for W / W / 80 W amplifier, max. + db gain at 7 output level alidation that the power amplifier is not in saturation for the selected test level including 80% AM, see IEC Ed. for more information (only available for firmware operation) Free parameter setting from to G, supports external power amplifier, switch SW 070, monitoring probe MD 070, directional coupler and attenuator

8 C Windows software General: Remote control: Data transfer: The windows software includes the firmware functionality. The following additional features are available see below. The software allows the use of the report generator and all post processing features without the remote connection to the. Remote control of via LAN, or RS Transfer between and PC via remote connection or with stick Software: Generator menu Windows software: Generator mode Display: Single step mode: display (units,, ) with reference value setting, min. / max. display and export to a log file (frequency, time, power), EUT monitoring display Synchronized frequency sweep with power measurement, output as graph and ASCII file (application: scalar analysis on quadripole networks) Software: Immunity test setup Windows software: Immunity mode Sweep: EUT threshold search: EUT monitoring: Additional features: One click report generation: Export function: Level sweep with start and stop value or with free editable table, level profile editor and sweep function for BCI tests Different opportunities for manual and automatic control use as EUT monitoring device, keyboard activity for test interrupt with possibility for writing test report comments (EUT reaction etc.), output control for user port For each frequency step or each monitoring event output control for user port (to control a switch for the use of two amplifier) Tool for test report generation in rtf format, works with different user changeable templates, post processing of measurement data (input for test conditions, EUT parameters and comments), free changeable structure and items of the report, user support of repetitive inputs Result and calibration files can be converted to txt files, graphs can be zoomed and converted to jpg files Software: EUT monitoring setup

9 C Analog ports Front panel Generator output: amplifier input: amplifier output: channel to : N socket 0 Ω, to G N socket 0 Ω, max. +0 N socket 0 Ω as defined in chapter panel Monitoring input analog: BNC socket, 0 to Ri= kω, m resolution External modulation input: BNC socket, impedance >0 kω, level: pp to get 00% AM, to 0 0 reference output: BNC socket, approx. pp / 0 Ω Digital ports front panel with ports Front panel : host connector for stick, keyboard, mouse panel User port: Monitoring digital input: Monitoring optical input: Trigger input: RS: RS optical: x : device connector: Network: D-Sub pole TTL inputs TTL outputs + / 800 ma, - / 00 ma, + / 800 ma power supply BNC socket 0 to via optical coupler Ri=. kω, switching threshold approx. to LWL (Light wave connector), HP versatile link HFBR00 series 0 kbd, (avoid scattered light on the back panel) BNC socket, TTL for external triggering, max. frequency 00, trigger delay <0 ms D-Sub pole, up to 00 Bd Connector x HFBRx socket for mm fiber optic cable with length between m and 0 m with 00 Bd, for other distances 800 Bd, max. 0 m host connector for stick, keyboard, mouse For remote control RJ, Ethernet 0 / 00 BASE-T

10 C supply consumption 00 to 0 AC 0 / 0 autoranging Recommended fuse F for nominal 0 Recommended fuse F for nominal 0 C-0 approx. 80 W A (slow) 0. A (slow) C-, C-0, C-, C-0 and C-80 approx. W. A (slow). A (slow) General data Operating temperature range: 0 C to 0 C Storage temperature range: -0 C to 0 C Relative humidity: % / 0 C (no moisture condensation) EMC: DIN / EN -:00 Shock: DIN / EN ibration: DIN / EN Protection class: DIN / EN 00- / IEC 00- Mechanical specifications Size (W x H x D) : Weight: cm ( ) x cm (HU) x. cm (with handle bar and foot) approx. kg (with internal power amplifier), approx. 8 kg (without internal power amplifier) Size of cardboard box: 80 cm x cm x cm (also for options ATN 0xx and / or LE 070 additional space available) Weight of cardboard box: approx. 8 kg (empty)

11 out < +0 out < +0 ch. < +0 ch. < +0 ch. < +7 ch. < +0 ch. < +0 ch. < +7 out < +0 ch. < +0 ch. < +0 ch. < +7 EM clamp / EM-Koppelzange KEMZ 80A EUT nd nd nd C Application for IEC / EN 000--, calibration set-up with CDN db Attenuator Compact generator with built-in power amplifier 0 Ω/0 Ω adapter CDN 0 Ω/0 Ω adapter 0 Ω 00 Ω AE Port EUT Port 00 Ω Common mode adapter ch. 0 Ω termination Ground plane Application for IEC / EN 000--, EUT set-up with CDN Compact generator with built-in power amplifier with CDNs db attenuator Auxiliary equipment CDN Equipment under test EUT AE AE Port EUT Port Ground plane Insulating Application for IEC / EN 000--, calibration set-up with EM clamp Compact generator with built-in power amplifier db attenuator Termination AE-side EUT-side 0 Ω 00 Ω KEMZ 80A 00 Ω Reference ground plane CAL 80A adapter set

12 out < +0 out < +0 ch. < +0 ch. < +0 ch. < +7 ch. < +0 ch. < +0 ch. < EM clamp / EM-Koppelzange KEMZ 80A EUT nd nd C Application for IEC / EN 000--, calibration set-up with current injection probe Compact generator with built-in power amplifier ch. 0 Ω termination LE 070, cable set for, consist of: cable, N(m)-N(m), m with one right-angle plug, RG; cable, N(m)-BNC(m), m, RG; cable, BNC(m)-N(m), 0 mm; cable, N(m)-N(m), 0 mm; Adapter N(m)-N(m); Adapter N(f)-BNC(m) db attenuator Calibration jig Current injection probe 0/0 Ω adapter Ground plane Application for IEC / EN 000--, EUT set-up with EM clamp or current injection probe and for example with use of a monitoring probe Compact generator with built-in power amplifier db attenuator Auxiliary equipment Equipment under test AE AE-side EUT-side EUT KEMZ 80A Insulating Reference ground plane Monitoring probe MD 070 Insulating

13 out < +0 out < +0 ch. < +0 ch. < +0 ch. < +7 ch. < +0 ch. < +0 ch. < +7 DIRECTIONAL COUPLER DCP DIRECTIONAL COUPLER DCP nd nd C Application for automotive BCI, calibration set-up (example with external power amplifier and directional coupler) output Attenuator as required for the test level ch. stress level ch. forward power ch. reverse power amplifier input 0 Ω Termination Output Directional coupler Calibration jig BCI probe Ground plane Application for automotive BCI, EUT set-up with monitoring probe (example with external power amplifier and directional coupler) output ch. level monitoring ch. forward power ch. reverse power -0 combined with switch network and power amplifiers for a complex solution e.g. automotive BCI amplifier input Output solution Auxiliary equipment AE EUT Directional coupler Insulating BCI probe Monitoring probe Ground plane Equipment under test

14 Output EUT out < +0 out < +0 ch. < +0 ch. < +0 ch. < +7 ch. < +0 ch. < +0 ch. < +7 out < +0 ch. < +0 ch. < +0 ch. < +7 nd nd nd C Application for automotive BCI, calibration set-up (example with C-0) 0 Ω Termination Attenuator as required for the test level Compact generator C-0 Calibration jig BCI probe Ground ch. plane Application for automotive BCI, EUT set-up with monitoring probe and LISN (example with C-0) H-AN 0 MD 070 Equipment under test Compact generator C-0 EUT To power supply LISN BCI probe Ground plane Application for IEC / EN up to G (example with -; field probe control requires optional software e.g. WIN 000) Software Compact generator - with built-in power amplifier for frequency range to G GTEM cell

15 C Delivery items for the series with rack mounting kit Compact immunity test system, to G generator and power meter (power amplifier as selected); remote control software on stick; spare fuses (); RS cable (Nullmodem); USO 0 ( to serial / optical converter with 0 m optical cable); LAN cable, crossover, m; keyboard (English); mains cable GB, CH, USA / JP, EU; operating manual Model No. and options SW 070, switch network xspdt ATN 0, db attenuator 0 W Teseq GmbH Landsberger Str. Berlin Germany T F info.rf.cts@ametek.com August 07 Teseq Specifications subject to change without notice. Teseq is an ISO-registered company. Its products are designed and manufactured under the strict quality and environmental requirements of the ISO 00. This document has been carefully checked. However, Teseq does not assume any liability for errors or inaccuracies. Part number Description 7 C-0 Compact immunity test system to G generator and power meter (without power amplifier) 7 C- Compact immunity test system, to G generator and power meter (with W module 0 to 0 ) 7 C-0 Compact immunity test system, to G generator and power meter (with 0 W module 0 to 00 ) 7 C- Compact immunity test system, to G generator and power meter (with W module to G) 708 C-0 Compact immunity test system, to G generator, to G -channel power meter ( inputs, used internal), 0 W power ampl. module 0 to 00 (>0 W to 0 ) 7 C-80 Compact immunity test system, to G generator and power meter (with 80 W module 0 to 0 ) 7-0 -TC Traceable calibration (ISO70), order only with the device 8-0 -DAkkS DAkkS calibration (ISO70), order only with the device 80 Rack Rack mounting kit for (red handles) 80 SW 070 Option for : -Switch network x SPDT 0 LE 070 cable set for 80 ATN 00 db Attenuator 0 W cw N(f)-N(f) 7 ATN 0 db Attenuator 0 W cw N(f)-N(f) 78 ATN 00 db Attenuator 00 W cw N(f)-N(f) 7 icd.control Software License for one generator B-xx, C-xx 8-7 E0 August 07

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY Integrated signal generator to G power meter inputs to G Integrated class A power amplifier module for different applications: W, 0 to 0 ; 0 W, 0 to 00 ;

More information

NSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter

NSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter The, successor of the NSG 070, is a multifunctional EMC immunity test system. Its large frequency range from to G and its modular set-up using internal or external amplifiers enable a large variety of

More information

TesT system for ConduCTed and radiated immunity

TesT system for ConduCTed and radiated immunity nsg 070 TesT system for ConduCTed and radiated immunity The, successor of the NSG 070, is a multifunctional EMC immunity test system. Its large frequency range from to G and its modular set-up using internal

More information

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY Integrated signal generator to G power meter inputs to G Integrated class A power amplifier module for different applications: W, 0 to 0 ; 0 W, 0 to ; W,

More information

RADIATED IMMUNITY TEST SYSTEM 6 GHz

RADIATED IMMUNITY TEST SYSTEM 6 GHz Integrated signal generator 80 MHz to 6 GHz Integrated RF switch network Integrated freely configurable pulse modulators ( µs to 00 s) for radar pulse profiles Multiple options.5 TFT color display Safety

More information

Radiated Immunity Test System 6 GHz

Radiated Immunity Test System 6 GHz The consist of an integrated RF signal generator, RF switch and interfaces. The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range. In addition to the generator,

More information

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN out < +0 out < +0 ch. < +0 ch. < +0 ch. < +7 ch. < +0 ch. < +0 ch. < +7 LL LL nd nd 0 8... Test setup calibration with a CDN The calibration setup always refers to the type of CDN. The CDN user manuals

More information

MONITORING DEVICE 4 khz to 400 MHz

MONITORING DEVICE 4 khz to 400 MHz The monitoring device can be used as an active or passive current sensor probe to measure the current in a conductor without connecting it directly. The allows fast and easy measurement as it can be quickly

More information

Radiated immunity test system 6 GHz

Radiated immunity test system 6 GHz its 6006 The consist of an integrated RF signal generator, RF switch and interfaces. The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range. In addition to the

More information

Coupling / decoupling network (CDN) for screened or coaxial cables

Coupling / decoupling network (CDN) for screened or coaxial cables IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq

More information

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the of cable and the intended signal carried on the cable. Teseq offers

More information

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W FOR TESTS ACCORDING TO... > BMW GS 95002 (2010) > DaimlerChrysler DC-10614 > DaimlerChrysler DC-11224 > EN 300329 > EN 300340 > EN 300342-1 > EN 300386 V1.3.2

More information

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W FOR TESTS ACCORDING TO... > EN 300329 > EN 300340 > EN 300342-1 > EN 300386 V1.3.2 > EN 301489-1 > EN 301489-17 > EN 301489-24 > EN 301489-7 > EN 55024 > EN 61000-4-6

More information

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W FOR TESTS ACCORDING TO... > EN 300329 > EN 300340 > EN 300342-1 > EN 300386 V1.3.2 > EN 301489-1 > EN 301489-17 > EN 301489-24 > EN 301489-7 > EN 55024 > EN 61000-4-6

More information

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz IEC / EN 6000-4-6 specifies the design and performance of a range of coupling networks. Each coupling network is related to the type of cable and connector. An specific 60 db decoupling network is required

More information

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M 1 CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL 601-142M CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL CDN 117 / 117-M

More information

CONDUCTED RF EQUIPMENT POWER AMPLIFIERS. Practical RF Immunity System Design Considerations

CONDUCTED RF EQUIPMENT POWER AMPLIFIERS. Practical RF Immunity System Design Considerations CONDUCTED RF EQUIPMENT POWER AMPLIFIERS Practical RF Immunity System Design Considerations 1 Designing a System Key considerations are the amplifier and antenna combination Determining what Power Amplifier

More information

Schlöder GmbH - EMC Test and Measurement Systems Model #

Schlöder GmbH - EMC Test and Measurement Systems Model # Schlöder GmbH - EMC Test and Measurement Systems Model # Product Description IEC / EN 61000-4 - 2 ESD SESD 216 ESD generator 10 kv CON / 16,5 kv AIR acc. to IEC 61000-4-2, 150 pf / 330 ohm SESD 230 ESD

More information

We re In The Business Of Making Your Life Easier

We re In The Business Of Making Your Life Easier Systems RF Conducted Immunity System We re In The Business Of Making Your Life Easier AS00202 4 khz 200 MHz System AS03007 10 khz 3 GHz System RF Conducted Immunity Testing to IEC, Military & Automotive

More information

Spectrum Analyzer R&S FS300

Spectrum Analyzer R&S FS300 Spectrum Analyzer R&S FS300 9 khz to 3 GHz The new product family from Rohde & Schwarz Professional test equipment for laboratory, service and production The R&S FS300 is a highly accurate spectrum analyzer

More information

Vector Network Analyzers ZVB

Vector Network Analyzers ZVB Specifications Version 05.00 Vector Network Analyzers ZVB September 2005 Specifications MEASUREMENT RANGE...3 MEASUREMENT SPEED...5 MEASUREMENT ACCURACY...6 EFFECTIVE SYSTEM DATA...8 TEST PORT OUTPUT...8

More information

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03 Electronic AC Load Series 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Rev. 3.03 Electronic AC Loads, Series Interface overview RS-232 USB GPIB LAN System bus Analog / Analog isolated X X Standard

More information

R&S SMB100N SIGNAL GENERATOR

R&S SMB100N SIGNAL GENERATOR R&S SMB100N SIGNAL GENERATOR PERFORMANCE SPECIFICATIONS VERSION 02.00, SEPTEMBER 2009 CONTENTS Specifications...3 Definitions... 3 RF performance... 4 Frequency... 4 Frequency sweep... 4 Reference frequency...

More information

Keysight Technologies N9320B RF Spectrum Analyzer

Keysight Technologies N9320B RF Spectrum Analyzer Keysight Technologies N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has

More information

Agilent N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer Agilent N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has been turned

More information

THE MODULAR SOLUTION FOR 6 KV APPLICATIONS

THE MODULAR SOLUTION FOR 6 KV APPLICATIONS THE MODULAR SOLUTION FOR 6 KV APPLICATIONS Teseq s new NSG 3060 conducted immunity generator takes the proven, user-friendly design of the highly successful Modula series to a new level. This innovative

More information

RADIATED IMMUNITY TEST SYSTEMS

RADIATED IMMUNITY TEST SYSTEMS FRANKONIA CONDUCTED RF IMMUNITY TEST SYSTEMS EMMISSION TEST SYSTEMS BROADBAND ANTENNAS CONDUCTED RF IMMUNITY TEST SYSTEMS RF-POWER-AMPLIFIER S RADIATED IMMUNITY TEST SYSTEMS ANECHOIC CHAMBERS, SHIELDED

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) R3000 EMI TEST RECEIVERS Fully IF digital EMI Receivers family for measurement of electromagnetic interference from

More information

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Model 865 RF / Ultra Low Noise Microwave Signal Generator Model 865 RF / Ultra Low Noise Microwave Signal Generator Features Excellent signal purity: ultra-low phase noise and low spurious Combination of highest output power and fastest switching Powerful touch-display

More information

Spectrum Analyzers 2680 Series Features & benefits

Spectrum Analyzers 2680 Series Features & benefits Data Sheet Features & benefits n Frequency range: 9 khz to 2.1 or 3.2 GHz n High Sensitivity -161 dbm/hz displayed average noise level (DANL) n Low phase noise of -98 dbc/hz @ 10 khz offset n Low level

More information

COUPLING DECOUPLING NETWORKS FOR IEC / EN

COUPLING DECOUPLING NETWORKS FOR IEC / EN COUPLING DECOUPLING NETWORKS FOR IEC / EN 60--6 IEC / EN 60--6 specifies the design and performance of a range of coupling / decoupling networks (s). Each is specific to the type of cable and the intended

More information

Portable Multi-Channel Recorder Model DAS240-BAT

Portable Multi-Channel Recorder Model DAS240-BAT Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes

More information

JD723A/JD724B/JD726A Cable and Antenna Analyzers

JD723A/JD724B/JD726A Cable and Antenna Analyzers COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS JD723A/JD724B/JD726A Cable and Antenna Analyzers Key Features Portable and lightweight handheld instrument. Built in wireless frequency bands as well as the

More information

CAR - TEST - SYSTEM 14

CAR - TEST - SYSTEM 14 CAR - TEST - SYSTEM 14 EMC-Test Equipment for electrical installation of vehicles Acc. to ISO 7637-2, ISO 16750-2 ISO 21848 Rise time variable 1-5µs Pulse Waveforms : #1 1-5/2000µs, 600 V, ISO 1-5/1000µs,

More information

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency Specifications Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency Features The Model is a solid-state, self -contained, air-cooled, broadband amplifier designed for applications requiring

More information

EMC TEST SYTEMS / INSTRUMENTS AND CONTROL SOFTWARE

EMC TEST SYTEMS / INSTRUMENTS AND CONTROL SOFTWARE EMC TEST SYTEMS / INSTRUMENTS AND CONTROL SOFTWARE Power Signal Generator - PSG-300 acc. to EN 61000-4-16 Compact Immunity Test System / BCI Test System - CIT-10 acc. to IEC/EN 61000-4-6 / ISO 11452-4

More information

RF Conducted Immunity and Automotive Transient Generator Test Systems

RF Conducted Immunity and Automotive Transient Generator Test Systems August 2008 RF Conducted Immunity and Automotive Transient Generator Test Systems rf/microwave instrumentation 1 This Will Get Your Pulse Going at whatever rate you need! DUT Coupling Network TGA20000

More information

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Electronic Load Electronic AC Loads, Interface overview RS-232 USB GPIB LAN System bus Analog X Analog isolated X Standard ption / not available 4226

More information

Complimentary Reference Material

Complimentary Reference Material Complimentary Reference Material This PDF has been made available as a complimentary service for you to assist in evaluating this model for your testing requirements. TMG offers a wide range of test equipment

More information

DSA700 Series Spectrum Analyzer

DSA700 Series Spectrum Analyzer DSA700 Series Spectrum Analyzer Product Features: All-Digital IF Technology Frequency Range from 100 khz up to 1 GHz Min. -155 dbm Displayed Average Noise Level (Typ.) Min.

More information

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN Description The setup of a radiated immunity test system can be done in the conventional way with many separate instruments or in a more comfortable and less risky way with our new EMC control unit, type

More information

2400C Series Microwave Signal Generators 10 MHz to 40 GHz. Preliminary Technical Datasheet. Low Phase Noise and Fast-Switching Speed in a Single Unit

2400C Series Microwave Signal Generators 10 MHz to 40 GHz. Preliminary Technical Datasheet. Low Phase Noise and Fast-Switching Speed in a Single Unit Preliminary Technical Datasheet 2400C Series Microwave Signal Generators 10 MHz to 40 GHz Low Phase Noise and Fast-Switching Speed in a Single Unit 2400C Series Microwave Signal Generator Signal Generator

More information

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing EMC PARTNER DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing This document has been optimized for electronic media Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management

More information

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC Coupling- / Decoupling Network 150 khz 300 MHz IEC 61000-4 - 6 and CISPR 15 / CISPR 22 150 khz 230 MHz IEC 61000-4 - 6 10 khz 230 MHz IEC 61000-4 - 6 and IEC 61326-3 - 2 and NE-21 Coupling and decoupling

More information

Voltage Transient Emission Test

Voltage Transient Emission Test Manual For Operation AN 200 Series Voltage Transient Emission Test AN 200 AN 200B The AN 200 is used to evaluate automotive electrical and electronic components for conducted emissions of transients along

More information

R&S ZNB Vector Network Analyzer Specifications

R&S ZNB Vector Network Analyzer Specifications Umschlag_ZNB4-8_dat-sw_en_5214-5384-22.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNB Vector Network Analyzer Specifications 07.11.2011 10:03:35 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

MGA Magnetic field system. DC khz

MGA Magnetic field system. DC khz MGA 1030 Magnetic field system DC - 250 khz EN 55103-1 + 2, EN 61000-4-8, Automotive, MIL-STD a.o. Generation and measurement of magnetic fields from DC up to 250 khz Field strengths up to 1000 A/m Additional

More information

R&S ZNC Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

WaveStation Function/Arbitrary Waveform Generators

WaveStation Function/Arbitrary Waveform Generators Function/Arbitrary Waveform Generators Key Features High performance with 14-bit waveform generation, up to 500 MS/s sample rate and up to 512 kpts memory 2 channels on all models Large color display for

More information

Specification for Radiated susceptibility Test

Specification for Radiated susceptibility Test 1 of 11 General Information on Radiated susceptibility test Supported frequency Range : 20MHz to 6GHz Supported Field strength : 30V/m at 3 meter distance 100V/m at 1 meter distance 2 of 11 Signal generator

More information

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz

More information

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800 IN ONE UNIT: 800W precision power amplifier, Spectrum Analyzer, Signal Generator General: The MTS-800 is a compact test system for broadband generation and measurement of magnetic fields. Its internal

More information

DG5000 series Waveform Generators

DG5000 series Waveform Generators DG5000 series Waveform Generators DG5000 is a multifunctional generator that combines many functions in one, including Function Generator, Arbitrary Waveform Generator, IQ Baseband /IQ IF, Frequency Hopping

More information

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB SYNTHESIZED SIGNAL GENERATOR MG3633A GPIB For Evaluating of Quasi-Microwaves and Measuring High-Performance Receivers The MG3633A has excellent resolution, switching speed, signal purity, and a high output

More information

500 W up to 28,800 W 60 V up to 800 V 45 ma up to 2,700 A. Electronic Load ZS

500 W up to 28,800 W 60 V up to 800 V 45 ma up to 2,700 A. Electronic Load ZS 500 W up to 28,800 W 60 V up to 800 V 45 ma up to 2,700 A Electronic Load AC Electronic Loads, Interface overview RS-232 USB GPIB LAN System bus Analog X Analog isolated X Standard ption / not available

More information

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 All-in-one Digital EMI Analyzer 10 Hz - 3 GHz PMM 9010/30P EMI Analyzer 10 Hz - 3 GHz Our trek started in a small laboratory over 25

More information

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009 EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009 Our trek started in a small laboratory over 25 years ago. Since then, we ve been focused on making EMC measurements easier and the measuring

More information

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m E M C T E S T S O L U T I O N S P A R T N E R S F O R H V & E M C S O L U T I O N S Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT w w w. h v t e c h n o l o g i e s. c o m Transient Immunity Generators

More information

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation ArbStudio Arbitrary Waveform Generators Powerful, Versatile Waveform Creation UNMATCHED WAVEFORM UNMATCHED WAVEFORM GENERATION GENERATION Key Features 125 MHz bandwidth 1 GS/s maximum sample rate Long

More information

Network Analyzers. R3765G/3767G Series. R3765G/67G Series Network Analyzers. 300 khz to 3.8 GHz/300 khz to 8 GHz

Network Analyzers. R3765G/3767G Series. R3765G/67G Series Network Analyzers. 300 khz to 3.8 GHz/300 khz to 8 GHz (Photo is R3767CG) R3765G/67G Series Network Analyzers The R3765G/67G-series network analyzers are vector network analyzers that incorporate a new RF circuit analysis technique. The measuring frequency

More information

GTEM cells. Emissions and immunity testing in a single, shielded environment

GTEM cells. Emissions and immunity testing in a single, shielded environment GTEM cells Emissions and immunity testing in a single, shielded environment GTEM cells Emissions and immunity testing in a single, shielded environment Function A GTEM (Gigahertz Transverse Electro Magnetic)

More information

RF Signal Generator RIGOL TECHNOLOGIES, INC.

RF Signal Generator RIGOL TECHNOLOGIES, INC. DSG800 Series RF Signal Generator Highly cost-effective economical RF signal generator Up to -105 dbc/hz (typical) phase noise Up to +20 dbm (typical) maximum output power Higher level of amplitude accuracy,

More information

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission Core-6 EMI Receiver 9 khz 6 GHz Features: Frequency ranges: 9 khz 30 MHz and 30 MHz 6 GHz Fully compliant acc. to CISPR 16-1-1

More information

RF Signal Generator SM300

RF Signal Generator SM300 RF Signal Generator SM300 9 khz to 3 GHz With compliments Helmut Singer Elektronik www.helmut-singer.de info@helmut-singer.de fon +49 241 155 315 fax +49 241 152 066 Feldchen 16-24 D-52070 Aachen Germany

More information

IEC Electrical fast transient / Burst immunity test

IEC Electrical fast transient / Burst immunity test CONDUCTED RF EQUIPMENT POWER AMPLIFIERS IEC 61000-4-4 Electrical fast transient / Burst immunity test IEC 61000-4-4 Electrical fast transient / Burst immunity test Markus Fuhrer Phenomenom open a contact

More information

GFT1504 4/8/10 channel Delay Generator

GFT1504 4/8/10 channel Delay Generator Features 4 independent Delay Channels (10 in option) 100 ps resolution (1ps in option) 25 ps RMS jitter (channel to channel) 10 second range Channel Output pulse 6 V/50 Ω, 3 ns rise time Independent control

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) 1 MIG Tester Type MIG2000-6 Technical Specification E-MIG2000-6 revised: 07. May 2009 1 MIG Tester Type MIG2000-6 1

More information

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges) PERFORMANCES 12 ranges of AC current from 16 ma to 128 A peak AC permanent current up to 26 ARMS Nine ranges of DC permanent current from 16 ma to 12 A DC current ± 6mA or ± 10 ma stackable to AC current

More information

Signal Generator SML

Signal Generator SML Signal Generator SML Economy at its best 9 khz to 1.1 GHz/2.2 GHz/3.3 GHz SSB phase noise: < 122 dbc (1 Hz) (at f = 1 GHz, f = 20 khz) Setting times

More information

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Dual Channel Function/Arbitrary Waveform Generators 4050B Series Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/ Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary

More information

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS SYNTHESIZED SIGNAL GENERATOR MG3641A/MG3642A 12 khz to 1040/2080 MHz NEW New Anritsu synthesizer technology permits frequency to be set with a resolution of 0.01 Hz across the full frequency range. And

More information

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC standards. Presented by: Karim Loukil & Kaïs Siala Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards

More information

LVA series of 4-Quadrant amplifiers

LVA series of 4-Quadrant amplifiers LVA series of 4-Quadrant amplifiers AUTOMOTIVE SUPPLY SIMULATION AT IT S BEST LVA 1 Front panel Extremely low harmonic distortion - even under very non-linear load conditions Very fast slew rate > 2V/µs

More information

Test and Measurement for EMC

Test and Measurement for EMC Test and Measurement for EMC Bogdan Adamczyk, Ph.D., in.c.e. Professor of Engineering Director of the Electromagnetic Compatibility Center Grand Valley State University, Michigan, USA Ottawa, Canada July

More information

Model 845-M Low Noise Synthesizer

Model 845-M Low Noise Synthesizer Model 845-M Low Noise Synthesizer Features Low phase noise Fast switching down to 20 µs FM, Chirps, Pulse Internal OCXO, external variable reference Single DC supply Applications ATE LO for frequency converters

More information

Power Meter NRVS. Power, level and voltage measurements from DC to 40 GHz

Power Meter NRVS. Power, level and voltage measurements from DC to 40 GHz Power Meter NRVS Power, level and voltage measurements from DC to 40 GHz Accurate, general-purpose, easy-to-use Intelligent measuring heads: just plug them in and measure DC frequency input for tracking

More information

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz Handheld Spectrum Analyzer R&S FSH3 100 khz to 3 GHz Spectrum analysis anywhere, anytime The R&S FSH3 is the ideal spectrum analyzer for rapid, high-precision, cost-effective signal investigations. It

More information

R&S OSP Open Switch and Control Platform Specifications

R&S OSP Open Switch and Control Platform Specifications R&S OSP Open Switch and Control Platform Specifications Data Sheet Version 15.00 CONTENTS Definitions... 4 Introduction... 5 R&S OSP120... 5 R&S OSP130... 5 R&S OSP150... 5 R&S OSP-B200S2... 5 General

More information

R&S ZVT Vector Network Analyzer Specifications

R&S ZVT Vector Network Analyzer Specifications R&S ZVT Vector Network Analyzer Specifications Test & Measurement Data Sheet 08.00 CONTENTS Definitions... 3 Specifications... 4 Measurement range...4 Measurement speed...5 Measurement accuracy...6 Effective

More information

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) Agilent E571C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz khz to 4.5/6.5/8.5 GHz (with bias tees) 3 khz to 14/2 GHz (with bias tees) E592A Configurable Multiport Test Set Data Sheet Table of Contents

More information

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) Agilent E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 0 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) E5091A Multiport Test Set E5092A Configurable Multiport Test

More information

Agilent ESA-L Series Spectrum Analyzers

Agilent ESA-L Series Spectrum Analyzers Agilent ESA-L Series Spectrum Analyzers Data Sheet Available frequency ranges E4403B E4408B 9 khz to 1.5 GHz 9 khz to 3.0 GHz 9 khz to 26.5 GHz As the lowest cost ESA option, these basic analyzers are

More information

Coupling/Decoupling Networks (CDN)

Coupling/Decoupling Networks (CDN) Coupling/Decoupling Networks (CDN) For immunity testing according to IEC / EN 61000-4-6 Immunity testing CDNs are the preferred coupling and decoupling devices, for reasons of test reproducibility and

More information

LVA 4-Quadrant Amplifier 1000

LVA 4-Quadrant Amplifier 1000 LVA 4-Quadrant Amplifier 1 AUTOMOTIVE SUPPLY SIMULATION AT IT S BEST The relating standards: ISO 7637-2/-3 ISO 167-2 ISO 21848 LV 124 VDA 32 (LV 148) SAE J 1113-11 BMW GS 92 BMW GS 924-2-2 BMW GS 926 Ford

More information

ArbStudio Arbitrary Waveform Generators

ArbStudio Arbitrary Waveform Generators ArbStudio Arbitrary Waveform Generators Key Features Outstanding performance with 16-bit, 1 GS/s sample rate and 2 Mpts/Ch 2 and 4 channel models Digital pattern generator PWM mode Sweep and burst modes

More information

Model 865-M Wideband Synthesizer

Model 865-M Wideband Synthesizer Model 865-M Wideband Synthesizer Features Wideband Low phase noise Fast switching down to 20 µs FM, Chirps, Pulse Internal OCXO, external variable reference Single DC supply Applications ATE LO for frequency

More information

Surge Generator for MIL-STD 1275

Surge Generator for MIL-STD 1275 Surge Generator for MIL-STD 1275 This generator PG1275 is specially designed for the test of the susceptibility to surges and spikes of military 28 Vdc electric circuits. The equipment allows performing

More information

High-precision process calibrator Model CED7000

High-precision process calibrator Model CED7000 Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry

More information

R&S OSP Open Switch and Control Platform Specifications

R&S OSP Open Switch and Control Platform Specifications R&S OSP Open Switch and Control Platform Specifications Data Sheet Version 18.00 CONTENTS Definitions... 4 Introduction... 5 R&S OSP120... 5 R&S OSP130... 5 R&S OSP150... 5 R&S OSP-B200S2... 5 General

More information

WaveStation Function/Arbitrary Waveform Generators

WaveStation Function/Arbitrary Waveform Generators WaveStation Function/Arbitrary Waveform Generators Key Features High performance with 14-bit, 125 MS/s and 16 kpts 2 channels on all models Large 3.5 color display for easy waveform preview Over 40 built-in

More information

Specification for Conducted Emission Test

Specification for Conducted Emission Test 1 of 10 1. EMI Receiver Frequency range 9kHz 7.0 GHz Measurement time per frequency 10 µs to 100 s time sweep, span = 0 Hz - 1 µs to 16000 s Sweep time in steps of 5 % frequency sweep, span 10 Hz - 2.5

More information

Kistler LabAmp for DynoWare

Kistler LabAmp for DynoWare Electronics & Software Kistler LabAmp for DynoWare Charge Amplifier and Data Acquisition for Multicomponent Force Measurement This instrument is ideal for multicomponent force-torque measurement with piezoelectric

More information

DIGITAL LINK MEASURING INSTRUMENTS MS371A/A1 GPIB PCM CHANNEL ANALYZER. For Simultaneous Measurement of 30 Channels with MS120A

DIGITAL LINK MEASURING INSTRUMENTS MS371A/A1 GPIB PCM CHANNEL ANALYZER. For Simultaneous Measurement of 30 Channels with MS120A PCM CHANNEL ANALYZER MS371A/A1 For Simultaneous Measurement of 30 Channels with MS120A (MS371A1) GPIB The MS371A/A1 is an overall measuring instrument with many measuring functions for digital primary

More information

Chapter 5 Specifications

Chapter 5 Specifications RIGOL Specifications are valid under the following conditions: the instrument is within the calibration period, is stored for at least two hours at 0 to 50 temperature and is warmed up for 40 minutes.

More information

HZ530 Near-Field Probe Set

HZ530 Near-Field Probe Set HZ530 Near-Field Probe Set The HZ530 Probe Set consists of three active broadband probes for EMI diagnosis. The probes are designed for connection to a HAMEG spectrum analyzer with input impedance of 50

More information

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

COUPLING DECOUPLING NETWORK MODEL CDN-AF4 COUPLING DECOUPLING NETWORK MODEL CDN-AF4 II Warranty Com-Power warrants to its Customers that the products it manufactures will be free from defects in materials and workmanship for a period of 2 years.

More information

R&S ZVT Vector Network Analyzer Specifications

R&S ZVT Vector Network Analyzer Specifications ZVT_dat-sw_en_0758-065-22_v0900_cover.indd Data Sheet 09.00 Test & Measurement R&S ZVT Vector Network Analyzer Specifications 06.03.205 5:50:4 CONTENTS Definitions... 3 Specifications... 4 Measurement

More information

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA MIL Standard 461 G final release December 11 th, 2015 EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA CDN-UTP8 Ed. 3 - Universal The Swiss CDN company for data EMC and telecom

More information

CS114 + CS115 + CS116

CS114 + CS115 + CS116 System description Test Setup for MIL-STD-461 D, E&F CS114 + CS115 + CS116 1. MONTENA EMC... 2 1.1 PRODUCTS... 3 1.2 TURN KEY MIL STD 461 TEST INSTALLATIONS... 3 2. TEST SETUP DESCRIPTION... 4 2.1 TEST

More information