Schlöder GmbH - EMC Test and Measurement Systems Model #

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Schlöder GmbH - EMC Test and Measurement Systems Model #"

Transcription

1 Schlöder GmbH - EMC Test and Measurement Systems Model # Product Description IEC / EN ESD SESD 216 ESD generator 10 kv CON / 16,5 kv AIR acc. to IEC , 150 pf / 330 ohm SESD 230 ESD generator 30 kv CON / 30 kv AIR acc. to IEC , 150 pf / 330 ohm SESD ESD generator 30 kv CON / 30 kv AIR acc. to IEC and ISO 10605/2008, 150 pf/ 330 ohm, mechanical polarity module (to reverse the polarity of the pulses, the module must be removed, turned 180 degrees and reinserted), includes factory calibration for 150 pf/330 ohm SESD P ESD generator 30 kv CON / 30 kv AIR acc. to IEC and ISO 10605/2008, 150 pf/ 330 ohm, electronic polarity module (A Polarity Switch allows the user to quickly and easily change the polarity of the pulses), includes factory calibration for 150 pf/330 ohm SESD A SESD 30 S 100 KAL SESD KAL SESD KAL SESD SESD 30 C 50 SESD 30 C 100 SESD 30 C 150 SESD 30 C 200 SESD 30 C 250 SESD 30 C 300 SESD 30 C 330 SESD 30 C 500 SESD 30 C 680 SESD 30 C 1000 SESD 30 R 0 SESD 30 R 50 SESD 30 R 100 SESD 30 R 150 SESD 30 R 200 SESD 30 R 250 SESD 30 R 330 SESD 30 R 500 SESD 30 R 560 SESD 30 R 1000 SESD 30 R 1500 SESD 30 R 2000 SESD 30 R 5000 SESD 30 P 200 SESD 30 M 200 SESD 30 T 630 SESD 3036 SESD 3036 SESD 30 Z 01 SESD 30 Z 02 SESD 3021 SESD 3025 SESD 3026 SESD 3027 ESD generator 30 kv CON / 30 kv AIR acc. to IEC and ISO 10605/2008, 150 pf/ 330 ohm, electronic polarity module, includes factory calibration for 150 pf/330 ohm, battery and main operation, includes factory calibration for 150 pf/330 ohm Control software ESD, with optical interface and fiber optic cable 10m. For the generators SESD 216, SESD 230, SESD refers to the impedances 150 pf / 330 Ω (IEC), because the conversion with the HBM module in ISO calibration (4 impedances 202 values), before delivery of a new ESD generator, if refers to the impedances 100 pf / 1500 Ω, only rise time and peak current are measured becau Capacity module 50 pf Capacity module 100 pf Capacity module 150 pf Capacity module 200 pf Capacity module 250 pf Capacity module 300 pf Capacity module 330 pf Capacity module 500 pf Capacity module 680 pf Capacity module 1000 pf Resistor module 0 ohm,only for AIR discharge,c max 330 pf Resistor module 50 ohm Resistor module 100 ohm Resistor module 150 ohm Resistor module 200 ohm Resistor module 250 ohm Resistor module 330 ohm Resistor module 500 ohm Resistor module 560 ohm Resistor module 1000 ohm Resistor module 1500 ohm Resistor module 2000 ohm Resistor module 5000 ohm Electronic polarity module Fast discharge module, rise time < 400 ps Balancer for ESD Hook on the generator - for hanging on a balancer. Before delivery of a new ESD generator, if a customer purchase a new ESD generator Hook on the generator - for hanging on a balancer. Mounting a hook for an existing customer SESD xxx generator BNC trigger output, instead of a trigger input Special module with HV cable 1m long (instead of test tip) Test tip (metal part) Contact discharge, 30 kv, standard Test tip (metal part) Air discharge, 30 mm half ball Test tip (metal part) CON with spring contact, 50 mm long Test tip (metal part) CON with spring contact, 70 mm long

2 SESD 30 MOD-1 HBM (Human Body Model) module 5 ns (100 pf/1500 ohm), 100 pf module and 330 ohm module are needed - the 1500Ω are obtained by the HBM module ohm. Included plot. SESD 30 MOD-1-U2 Modification of an existing SESD for option HBM (MOD-1) SESD 30 MOD-3-U1 Modification of an existing SESD for automatic absorbing. Calibration has to be quoted additionally. SESD 231 Discharge return cable, 2m long SESD 271 VCP vertical coupling plate, include earth cable SESD 272 SESD 272 Earth cable include 2 x 470 kohm resistor, 2 m long SESD ESD calibration set 2 ohm (4 GHz), traceable to National standard. Necessary acc. to the new revision of the standard IEC Included accredited calibration. ATT-20 Additional attenuator 20 db for the SESD SESD 2910 ESD test system, 30 kv for testing electro explosive devices acc. EN Basic unit, includes electronic polarity module, RS 232 interface. SESD 29 R 05 Resistor module 0,5 ohm SESD 29 R 2 Resistor module 2 ohm SESD 29 R 5 Resistor module 5 ohm SESD 29 R 10 Resistor module 10 ohm SESD 29 R 20 Resistor module 20 ohm SESD 29 R 150 Resistor module 150 ohm SESD 29 R 330 Resistor module 330 ohm SESD 29 R 500 Resistor module 500 ohm SESD 29 R 2000 Resistor module 2000 ohm SESD 29 R 5000 Resistor module 5000 ohm SESD 29 C 150 Capacity modules 150 pf SESD 29 C 200 Capacity modules 200 pf SESD 29 C 300 Capacity modules 300 pf SESD 29 C 330 Capacity modules 330 pf SESD 29 C 470 Capacity modules 470 pf SESD 29 C 500 Capacity modules 500 pf SESD 29 C 1000 Capacity modules 1000 pf SESD 29 C 1500 Capacity modules 1500 pf SESD 29 C 2000 Capacity modules 2000 pf SESD 29 C 2500 Capacity modules 2500 pf SESD 29 C 3000 Capacity modules 3000 pf SESD 29 C 3500 Capacity modules 3500 pf SESD 29 C 5000 Capacity modules 5000 pf SESD 2990 Transport case for max. 12 modules IEC / EN Burst SFT 1400 Burst generator 125 khz, 5 kv, acc. to IEC SFT 1420 Burst generator 2 MHz, 4.8 kv acc. to IEC SFT 415 Capacity clamp to test I/O leads, in conformity with IEC , includes the high-voltage cable. SFT Capacity clamp to test I/O leads, in conformity with IEC with special protection against touch, includes the high voltage cable. SFT 415-CS Calibration Set for calibration of the capacity coupling clamp acc. IEC , 2012 SFT Ohm Attenuator for calibration SFT 415; 54 db, conform divider 500:1 at 50 ohm termination (scope input) SFT Ohm Attenuator for calibration SFT 415 and SFT 1400, 1420; 60 db, conform divider 1000:1 at 50 ohm termination (scope input) SFT 450-Set 50 Ohm and 1000 Ohm Attenuator for calibration the SFT 415 and SFT 1400, SFT 1420 SFT 470 Probe set for Burst generator, to create short time magnetic fields IEC / EN Surge CWG 1500 Surge generator according to IEC , max. 4,4 kv CWG phase coupling network, 400 V / 4 x 16 A for burst and surge CWG phase coupling network, max. 550 V / 4 x 16 A for burst and surge CWG phase coupling network, 400 V / 4 x 32 A for burst and surge CWG phase coupling network, max. 550 V / 4 x 32 A for burst and surge

3 CWG phase coupling network, 400 V / 4 x 60 A for burst and surge CWG phase coupling network, max. 550 V / 4 x 60 A for burst and surge CWG 524-B 3-phase coupling network, 400 V / 4 x 60 A, for burst coupling only CWG 1525 Coupling network, 2 unshielded symmetrical data lines (field bus, interconnectin lines), 1 A, max. 50V AC/DC, coupling via gas arrestors CWG Coupling network, 0,5uF / 40 Ohm, 2 unshielded unsymmetrical interconnection lines, 4A/ 240 VAC, 120 VDC CWG Coupling network,, 2 unshielded unsymmetrical interconnection lines, 10A/ 240 VAC, 120 VDC CWG 1528 Coupling network, 0,5uF / 40 Ohm, 4 unshielded unsymmetrical interconnection lines, 6 A, 3 x 250 VAC, max. 120 VDC; Remote control RS 232 CWG 550 External 18 μf capacitor within a housing, acc. IEC Ed.3.0, 2014; max. 250 VAC, max. 400 VDC, max. pulse voltage 4,4 kv, include HV cable 35 cm, for verification of the Surge pulse / tests to cable shields. CWG 553 0,5 μf capacitor + 40 Ohm resistor within a housing, acc. IEC Ed.3.0, 2014; max. 250 VAC, max. 400 VDC, max. pulse voltage 4,4 kv, include HV cable 90 cm, for verification of the Surge pulse / tests to cable shields. CWG 554 External 18 μf and 9 μf capacitor and 10 ohm within a housing, acc. IEC Ed.3.0, 2014, max. 550 VAC, 1200 VDC, max. pulse voltage 6,0 kv, for Surge tests without coupling networks to cable shields and verification of the Surge pulse. Includes HV cable, to connect to the CWG 1500 CDG 6000-DC Conducted RF generator, acc. IEC , Ed.4.0, 100 khz 300 MHz, amplifier 25W for 10 V (15 V) with 80% AM (without 6 db), - built-in directional coupler CDG 6000 Conducted RF generator, acc. IEC , Ed.4.0, 100 khz 300 MHz, amplifier 25W for 10 V (15 V) with 80% AM (without 6 db), - without directional coupler CDG DC Conducted RF generator, acc. IEC , Ed.4.0, 100 khz 300 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 db), - built-in directional coupler CDG Conducted RF generator, acc. IEC , Ed.4.0, 100 khz 300 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 db), - without directional coupler CDG DC_10 Conducted RF generator, acc. IEC , Ed.4.0, 10 khz 250 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 db), - built-in directional coupler CDG _10 Conducted RF generator, acc. IEC , Ed.4.0, 10 khz 250 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 db), - without directional coupler CDG db Attenuator, 20W, for test level max. 20V CDG W 6 db Attenuator, 100W Coupling networks - Calibration adapters required Special CDNs upon requirement CDN L line, 250VAC, 16A, 150 khz 230 MHz, 4mm MC jack, black CDN M1 ground cable PE, 250 VAC, 150 khz 230 MHz, 4mm jack, gn/yellow CDN M1_10 ground cable PE, 250 VAC, 10 khz 230 MHz, 4mm jack, gn/yellow CDN M lines L + N, 250 VAC, 16 A, 150 khz 300 MHz CDN M2-16_10 2 lines L + N, 250 VAC, 16 A, 10 khz 230 MHz CDN M lines L + N, 250 VAC, 32 A, 150 khz 230 MHz CDN M2-32 HV 2 lines L + N, 600 VAC, 32 A, 150 khz 230 MHz CDN M2-63 HV 2 lines L + N, 600 VAC, 63 A, 150 khz 80 MHz CDN M2-100 HV 2 lines L + N, 600 VAC, 100 A, 150 khz 80 MHz CDN M2+M lines, switchable, 250 VAC, 16 A, 150 khz 300 MHz CDN M2+M3-16_ lines, switchable, 250 VAC, 16 A, 10 khz 230 MHz CDN M2+M lines, switchable, 250 VAC, 32 A, 150 khz 230 MHz CDN M lines L + N + PE, 250 VAC, 16 A, 150 khz 300 MHz CDN M3-L16 3 lines 3 x L, 250 VAC, 16 A, 150 khz 230 MHz CDN M lines L + N + PE, 250 VAC, 32 A, 150 khz 230 MHz CDN M3-L32 3 lines 3 x L, 250 VAC, 32 A, 150 khz 230 MHz CDN M3-L32_10 3 lines 3 x L, 250 VAC, 32 A, 10 khz 230 MHz CDN M3-LN32 3 lines L1 + L2 + N, 250 VAC, 32 A, 150 khz 230 MHz CDN M3-32 HV 3 lines L + N + PE, 600 VAC, 32 A, 150 khz 80 MHz CDN M3-63 HV 3 lines L + N + PE, 600 VAC, 63 A, 150 khz 80 MHz CDN M3-100 HV 3 lines L + N + PE, 600 VAC, 100 A, 150 khz 80 MHz CDN M3-L100 HV 3 lines, 3 x L 600 VAC, 100 A, 150 khz 80 MHz

4 CDN M lines 3 x L, 1 x PE, 250 VAC, 16 A, 150 khz 230 MHz CDN M4-N16 4 lines 3 x L, 1 x N, 250 VAC, 16 A, 150 khz 230 MHz CDN M lines 3 x L, 1 x PE, 250 VAC, 32 A, 150 khz 230 MHz CDN M4-N32 4 lines 3 x L, 1 x N, 250 VAC, 32 A, 150 khz 230 MHz CDN M4-32 HV 4 lines 3 x L, 1 x PE, 600 VAC, 32 A, 150 khz 80 MHz CDN M4-32_10 4 lines 3 x L, 1 x PE, 250 VAC, 32 A, 10 khz 230 MHz CDN M4-N63 HV 4 lines 3 x L, 1 x N, 600 VAC, 63 A, 150 khz 80 MHz CDN M4-63 HV 4 lines 3 x L, 1 x PE, 600 VAC, 63 A, 150 khz 80 MHz CDN M4-100 HV 4 lines 3 x L, 1 x PE, 600 VAC, 100 A, 150 khz 80 MHz, incl. cable 3m with 2 plugs. CDN M4-N100 HV 4 lines 3 x L, 1 x N, 600 VAC, 100 A, 150 khz 80 MHz, incl. cable 3m with 2 plugs. CDN M lines 3 x L, 1 x N, 1 x PE, 250 VAC, 16 A, 150 khz 230 MHz CDN M lines 3 x L, 1 x N, 1 x PE, 250 VAC, 32 A, 150 khz 230 MHz CDN M5-32 HV 5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 32 A, 150 khz 80 MHz CDN M5-32 VHV 5 lines 3 x L, 1 x N, 1 x PE, 1000 VAC, 32 A, 150 khz 80 MHz CDN M5-63 HV 5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 63 A, 150 khz 80 MHz CDN M5-100 HV 5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 100 A, 150 khz 80 MHz CDN S screened line, 75 Ohm connector BNC, 150 khz 230 MHz CDN S 1 1 screened line, connector BNC, 150 khz 230 MHz CDN S 1_10 1 screened line, connector BNC, 10 khz 230 MHz CDN S 2 2 screened lines, connector XLR, 150 khz 230 MHz CDN S 2_10 2 screened lines, connector XLR, 10 khz 230 MHz CDN S 3_10 3 screened lines, connector XLR, 10 khz 230 MHz CDN S 4 screened lines, connector XLR, 5 pole, 150 khz 230 MHz CDN S 8 screened lines, connector 8 pole Mini DIN, 150 khz 230 MHz CDN S 9 screened lines, connector 9-pol SUB-D, 150 khz 230 MHz CDN S 9_10 screened lines, connector 9-pol SUB-D, 10 khz 230 MHz CDN S 15 screened lines, connector 15-pol SUB-D, 150 khz 230 MHz CDN S 25 screened lines, connector 25-pol SUB-D, 150 khz 230 MHz CDN S K75-BNC Screened lines, for coaxial-cable 75 Ohm, BNC 150 khz 230 MHz CDN AF 2 2 unscreened non balanced lines, terminal clamp, 150kHz 300MHz CDN AF 2-MC 2 unscreened non balanced lines, 4mm MC jacks,150khz 300MHz CDN AF 2-MC_10 2 unscreened non balanced lines, 4mm MC jacks, 10kHz 230MHz CDN AF 3 3 unscreened non balanced lines, terminal clamp, 150kHz 230MHz CDN AF 3-MC 3 unscreened non balanced lines, 4mm MC jacks,150khz 230MHz CDN AF 3-MC_10 3 unscreened non balanced lines, 4mm MC jacks, 10kHz 230MHz CDN AF 4 4 unscreened non balanced lines, terminal clamp, 150kHz 230MHz CDN AF 4_10 4 unscreened non balanced lines, terminal clamp, 10 khz 230MHz CDN AF 4-MC 4 unscreened non balanced lines, 4mm MC jacks, 150kHz 230MHz CDN AF 4-MC_10 4 unscreened non balanced lines, 4mm MC jacks, 10kHz 230MHz CDN AF 5-MC 5 unscreened non balanced lines, 4mm MC jacks, 150kHz 230MHz CDN AF 5-MC_10 5 unscreened non balanced lines, 4mm MC jacks, 10kHz 230MHz CDN AF 8 8 unscreened non balanced lines, terminal clamp, 150kHz 230MHz CDN AF 8_10 8 unscreened non balanced lines, terminal clamp, 10kHz 80MHz CDN AF 8-MC 8 unscreened non balanced lines, 4mm MC jacks, 150kHz 80MHz CDN AF 8-MC_10 8 unscreened non balanced lines, 4mm MC jacks, 10kHz 80MHz CDN AF 8-SUBD_10 8 unscreened non balanced lines, 4mm SUB-D9, 10kHz 230MHz CDN AF 12 SUB-D 12 unscreened non balanced lines, SUB-D15, 150kHz 230MHz CDN T 2 2 unscreened balanced lines, terminal clamp, 150 khz 230 MHz CDN T 2_10 2 unscreened balanced lines, terminal clamp, 10 khz 80 MHz CDN T 4 4 unscreened balanced lines, terminal clamp, 150 khz 230 MHz CDN T 4_10 4 unscreened balanced lines, terminal clamp, 10 khz 80 MHz CDN T 8 8 unscreened balanced lines, terminal clamp, 150 khz 230 MHz CDN RJ 11 unscreened lines, 6 pins, RJ11 connector, 150 khz 230 MHz CDN RJ 45 unscreened lines, 8 pins, RJ45 connector, 150 khz 230 MHz CDN RJ 45S screened lines, 8 pins, screened RJ45 connector, 150 khz-230 MHz CDN RJ 45S_10 screened lines, 8 pins, screened RJ45 connector, 10 khz-230 MHz CDN HDMI screened lines, 19 pins, screened HDMI connector, 150kHz-230MHz, HDMI 1.3a CDN Firewire CDN for IEEE 1394 units, 6 pol, Firewire jack, 150 khz MHz

5 CDN CAN-BUS L4 CDN for CAN-BUS, 9 pol SUB-D socket, 150 khz MHz CDN CAN-BUS L5 CDN for CAN-BUS, 9 pol SUB-D socket, 150 khz MHz CDN USB-C CDN for central USB units, 8 pins connector, 150 khz MHz, EUT side: USB-B -> square, AE side: USB-A -> flat CDN USB-C_10 CDN for central USB units, 8 pins connector, 10 khz-230 MHz, EUT side: USB-B -> square, AE side: USB-A -> flat CDN USB-P CDN for periphery USB units, 8 pins connector, 150 khz-230 MHz, EUT side: USB-A -> flat, AE side: USB-B -> square CDN USB-P_10 CDN for periphery USB units, 8 pins connector, 10 khz-230 MHz, EUT side: USB-A -> flat, AE side: USB-B -> square CDN USB-3.0 CDN for USB 3.0, 150 khz-230 MHz, EUT side: USB-A -> flat, AE side: USB-A -> flat CDN D ohm resistor for direct injection, connectors: BNC / alligator clip CDNs for Emissions Testing CDN M2-16_9K EMI 2 lines L + N, for emissions testing, 250 VAC, 16A, 9 khz 300 MHz CDN M3-16_9K EMI 3 lines L+N+PE, for emissions testing, 250 VAC, 16A, 9 khz 300MHz Calibration material CDG A 3100 Mounting plate include 50/150 ohm passage and 50 ohm termination CDG Ohm resistor (50/150 ohm passage) BNC to BNC CDG A 3101 Calibration adaptor for CDN M3, M2, M1, L1 16A / 32A CDG A 3107 Calibration adaptor for CDN M5/M4-16/32A / AF5/AF4-MC (AE-port) CDG A 3128 Calibration adaptor for CDN M5/M4-16/32A / AF5/AF4-MC (EUTport) CDG A 3125 Calibration adaptor for CDN M3, M2, 63A CDG A 3126 Calibration adaptor for CDN M3, M2, 100A CDG A 3115 Calibration adaptor for CDN M5, M4, 63A CDG A 3116 Calibration adaptor for CDN M5, M4, 100A CDG A 3102 Calibration adaptor for CDN AF 2 CDG A 3101 Calibration adaptor for CDN AF 2-MC CDG A 3108 Calibration adaptor for CDN AF 3 CDG A 3101 Calibration adaptor for CDN AF 3-MC CDG A 3108 Calibration adaptor for CDN AF 4 CDG A 3107 Calibration adaptor for CDN AF 5/AF4-MC (AE-port) CDG A 3128 Calibration adaptor for CDN AF 5/AF4-MC (EUT port) CDG A 3110 Calibration adaptor for CDN AF 8 CDG A 3114 Calibration adaptor for CDN AF 8-MC CDG A 3143 Calibration adaptor for CDN AF 12-SUBD CDG A 3103 Calibration adaptor for CDN S 1 CDG A 3104 Calibration adaptor for CDN S 2 CDG A 3130 Calibration adaptor for CDN S 4 CDG A 3129 Calibration adaptor for CDN S 8 CDG A 3105 Calibration adaptor for CDN S 9 CDG A 3113 Calibration adaptor for CDN S 15 CDG A 3106 Calibration adaptor for CDN S 25 CDG A 3144 Calibration adaptor for CDN S K75-BNC CDG A 3111 Calibration adaptor for CDN T2 CDG A 3112 Calibration adaptor for CDN T4 CDG A 3109 Calibration adaptor for CDN T8 CDG A 3117 Calibration adaptor for CDN RJ 45 S CDG A 3118 Calibration adaptor for CDN RJ 45 CDG A 3120 Calibration adaptor for CDN RJ 11 CDG A 3121 Calibration adaptor for CDN USB-C (also USB 3.0C) CDG A 3122 Calibration adaptor for CDN USB-P (also USB 3.0P) CDG A 3123 Calibration adaptor for CDN HDMI CDG A 3127 Calibration adaptor for CDN Firewire CDG A 3131 Calibration adaptor for CDN CAN-BUS, 9-pol SUB-D male and CDN AF 8-SUBD_10 Coupling clamps CDN DCL-20 Decoupling clamp for immunity, acc. IEC , 100 khz 1000 MHz, cable diameter max. 20mm.

6 CDN EMCL-20 EM clamp acc. to /EC/EN incl. calibration kit and factory calibration, traceable, cable diameter max. 20 mm CDN EMCL-35 EM clamp acc. to /EC/EN incl. calibration kit and factory calibration, traceable, cable diameter max. 35 mm CDN-EMCL-NW_10 Matching network 10 khz 150 khz, for using EMCL 20 from 10 khz to 150 khz KAL SET EMCL Calibration set for EMCL, acc. IEC , Ed. 4.0, 2014 IEC / EN / EN / MIL STD / ISO DC khz MGA 1033 Magnetic field analyzer and generator acc. to EN IEC MIL-STD-461 E/F, DC-250 khz, Amplifier 50V / 16A MGA 1034_16-SYS Complete Test-System for Magnetic field tests acc. ISO , MIL-STD-461 E/F and other incl. compensation board and Triax Coil MGA_HCST_50-28 for magnetic fields until 1000 A/m at 1000 Hz, DC 250 khz, Amplifier 50V / 16A MGA_RLS 133 Radiating / Loop sensor 133 mm acc. to EN , incl. 3m cable MGA_RL 120 Radiating loop 120 mm acc. to MIL-STD-461E / RS101, 3m cable MGA_BC-500 Radiating loop 50 cm, acc. to EN , item A 3.1 MGA_LS 040 Loop sensor 40 mm acc. to MIL-STD-461E / RE101, incl. 3m cable MGA_LS 133 Loop sensor 133 mm acc. to MIL-STD-461E / RE101, 3m cable MGA_B1 Test adapter acc. to EN , Fig. B1 MGA_B2 Calibration network acc. to EN , Fig. B2 MGA_B4 Current transducer acc. to EN , Fig. B4 MGA_HCS_ Helmholtz coil 1-axis (50 khz) 1,00x1,00m, distance 0,60m MGA_HCS_ Helmholtz coil 1-axis (50 khz) 1,25x1,25m, distance 0,75m MGA_HCST_50-28 Helmholtz coil 3-axis (50 khz) 0,5 x 0,5m, distance 0,28m MGA_HCS_50-28 Helmholtz coil 1-axis (50 khz) 0,5 x 0,5m, distance 0,28m MGA_CT-50A Coupling transformer acc. MIL-STD-461 CS 101 MGA_ISS-19 Coupling transformer for tests acc. DO160, Sec. 19 (19.3.1; ; ), in combination with MGA 1033 MGA_SO_CE101 Software plug-in MIL-STD-461E / CE101 MGA_SO_CS101 Software plug-in MIL-STD-461E / CS101 MGA_SO_CS109 Software plug-in MIL-STD-461E / CS109 MGA_SO_4-16 Software plug-in EN IEC / EN Immunity DC 150 khz PGA Power Generator DC 300 khz; +/-50V; +/-5A, also for the continuous disturbances acc. IEC PGA Power Generator DC 300 khz; +/-50V; +/-16 A PGA 1240-PSG 300 Option External voltage-source, input for phase-triggering of an external voltage-source, 50 ohm output, for the short-term tests up to 300V. Option instead of PGA PGA 1330 Immunity generator for short-term tests up to 300 V, with 50 ohm serial resistor to the output IT - 06 IT - 16 CN M2-AC-32 CN M2-DC-32 CN M3-AC-32 CN M3-DC-32 CN M4-AC-32 CN M5-AC-32 CN CN CN M2+M3-32-HV CN AF 2 CN AF 4 CN AF 4 CN AF 8 CN T 2 CN T 4 Isolation transformer 6 A Isolation transformer 16 A Coupling network for 2 lines 250 VAC, 15 Hz 150 khz Coupling network for 2 lines 250 VDC Coupling network for 3 lines 250 VAC, 15 Hz 150 khz Coupling network for 3 lines 250 VDC Coupling network for 4 lines 250 VAC, 15 Hz 150 khz Coupling network for 5 lines 250 VAC, 15 Hz 150 khz Coupling network switchable M2, M3, M4, M5, 32A, 250 V AC+DC, 15 Hz 150 khz Coupling network switchable M2, M3, M4, M5, 125A, 250 V AC+DC, 15 Hz 150 khz CN for 2 and 3 lines, 32A, 520 VAC / 620 VDC, Housing 4 HE CN for 2 unsymmetrical, unshielded lines, DC, 15 Hz 150 khz CN for 4 unsymmetrical, unshielded lines, DC, 15 Hz 150 khz CN for 4 unsymmetrical, unshielded lines, DC, 15 Hz 150 khz with 4mm MC banana plugs CN for 8 unsymmetrical, unshielded lines, DC, 15 Hz 150 khz CN for 2 symmetrical, shielded data lines, DC, 15 Hz 150 khz CN for 4 symmetrical, shielded data lines, DC, 15 Hz 150 khz

7 CN T 8 CN for 8 symmetrical, shielded data lines, DC, 15 Hz 150 khz CN RJ 45 CN for unsymmetrical, unshielded RJ45, DC, 15 Hz 150 khz CN ITU-T CN acc. ITU - Fig.1/K 54, for Telecom lines IEC / EN and Voltage interruption and Voltage dips VIS 1700_1 Voltage interruption simulator according to IEC , AC and DC ramp function, includes factory calibration VIS 1700_1 VIS 740 Step transformer 16,0 A for voltage dips, AC using only, 0%, 40%, 70%, 80% - necessary to reach the requirement acc. IEC (should also quote KAL VIS 740) KAL VIS 740 Additional cost for factory calibration of the step transformer. Before delivery of a new VIS 740, if a customer orders the VIS 1700_1 and VIS 740 RF - Power Amplifier PA RF broadband power amplifier, 25 W, 100 khz 250 MHz PA RF broadband power amplifier, 75 W, 100 khz 300 MHz PA RF broadband power amplifier, 75 W, 100 khz 400 MHz PA RF broadband power amplifier, 75 W, 10 khz 250 MHz PA RF broadband power amplifier, 180 W, 1 MHz 400 MHz FNN Chapter Rules (Electricity Meters) PG Pulse generator 0,1μs/2000μs, 10 kv acc. FNN rules IEEE 644 CAL 1250 Generator of magnetic fields with 3 channel generator / amplifier for calibration 50 / 60 Hz. Additions EMV-SOFT Control software (MS-Windows ) for Schloeder EMC generators (Burst, Surge, Voltage interruption, 3-phase coupling networks)

Coupling / decoupling network (CDN) for screened or coaxial cables

Coupling / decoupling network (CDN) for screened or coaxial cables IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq

More information

COUPLING DECOUPLING NETWORKS FOR IEC / EN

COUPLING DECOUPLING NETWORKS FOR IEC / EN COUPLING DECOUPLING NETWORKS FOR IEC / EN 60--6 IEC / EN 60--6 specifies the design and performance of a range of coupling / decoupling networks (s). Each is specific to the type of cable and the intended

More information

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc. A Comparison Between MIL-STD and Commercial EMC Requirements Part 2 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC immunity

More information

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA MIL Standard 461 G final release December 11 th, 2015 EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA CDN-UTP8 Ed. 3 - Universal The Swiss CDN company for data EMC and telecom

More information

LANGER EMV-TECHNIK. Operating Instructions. A 100 / A 200 / A 300 Optical Fibre Probe

LANGER EMV-TECHNIK. Operating Instructions. A 100 / A 200 / A 300 Optical Fibre Probe LANGER EMV-TECHNIK Operating Instructions A 100 / A 200 / A 300 Optical Fibre Probe Contents: Page 1. Usage 2 2. Function 4 3. Operation 4 4. Safety instructions 5 5. Technical data 6 6. Scope of delivery

More information

Technical Specification

Technical Specification LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification E-MIG1203CWG revised: 22. June 2003 1 MIG Tester Type MIG1203CWG 1 MIG Tester Type MIG1203CWG 1 1.1 Introduction 1 2 General 2

More information

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

EMC Seminar Series All about EMC Testing and Measurement Seminar 1 EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Introduction to EMC Conducted Immunity Jeffrey Tsang Organized by : Department of Electronic Engineering 1 Basic Immunity Standards: IEC

More information

D10 Demonstration Board

D10 Demonstration Board D10 Demonstration Board D10 demonstration board side 1 Contents Demonstration board description 3 Measurement technology - Disturbance immunity 4 E1 disturbance immunity development system 4 P1 mini burst

More information

Combination Wave Test System

Combination Wave Test System Immunity Tests Combination Wave Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission Core-6 EMI Receiver 9 khz 6 GHz Features: Frequency ranges: 9 khz 30 MHz and 30 MHz 6 GHz Fully compliant acc. to CISPR 16-1-1

More information

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

BumbleBee. High Voltage Differential Probe Ord.-No: Features: High Voltage Differential Probe Ord.-No: 880-102-501 Features: 2000 V rms Measurement Category I, 6000 V transient Overvoltage 1000 V CAT III 400 MHz Bandwidth < 1 % Deviation within Specified Operating

More information

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN Description The setup of a radiated immunity test system can be done in the conventional way with many separate instruments or in a more comfortable and less risky way with our new EMC control unit, type

More information

P331-2 set ESD generator (IEC )

P331-2 set ESD generator (IEC ) User manual Probe set set ESD generator (IEC 61000-4-2) Copyright January 2017 LANGER GmbH 2017.01.09 User manual Table of contents: Page 1 ESD generator (IEC 61000-4-2) 3 1.1 Design and function of the

More information

ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing

ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing ESD3000 - MODULAR HANDHELD TESTER Electrostatic Discharge Testing Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management system. This is the foundation for an ISO 17025 accreditation

More information

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN out < +0 out < +0 ch. < +0 ch. < +0 ch. < +7 ch. < +0 ch. < +0 ch. < +7 LL LL nd nd 0 8... Test setup calibration with a CDN The calibration setup always refers to the type of CDN. The CDN user manuals

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3 KEYSIGHT TECHNOLOGIES, INC. SERVICE CENTERS 1346 Yellowwood Rd Kimballton, IA 51543 Brandt Langer Phone: 712 254 5100

More information

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed 17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:

More information

Oscilloscope Probes and Accessories

Oscilloscope Probes and Accessories Oscilloscope Probes and Accessories Pomona s oscilloscope probes give you the full range you need. Designed, rated, and specified to match the bandwidth of your instrument, they provide you with full voltage

More information

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M 1 CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL 601-142M CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL CDN 117 / 117-M

More information

CS114 + CS115 + CS116

CS114 + CS115 + CS116 System description Test Setup for MIL-STD-461 D, E&F CS114 + CS115 + CS116 1. MONTENA EMC... 2 1.1 PRODUCTS... 3 1.2 TURN KEY MIL STD 461 TEST INSTALLATIONS... 3 2. TEST SETUP DESCRIPTION... 4 2.1 TEST

More information

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted

More information

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed

More information

Test and Measurement for EMC

Test and Measurement for EMC Test and Measurement for EMC Bogdan Adamczyk, Ph.D., in.c.e. Professor of Engineering Director of the Electromagnetic Compatibility Center Grand Valley State University, Michigan, USA Ottawa, Canada July

More information

CE TEST CERTIFICATION

CE TEST CERTIFICATION according to Certification No.: E5NC004 European Standard EN 61000-6-4:2001 EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 61000-6-2:2001 ( IEC 61000-4-2:1995/A1:1998, IEC 61000-4-3: 1995/A1:1998,

More information

Emerging Standards for EMC Emissions & Immunity

Emerging Standards for EMC Emissions & Immunity Emerging Standards for EMC Emissions & Immunity Requirements for Industrial, Scientific, Medical & Information Technology Equipment CE Marking requirements are the path to increased market access Powerful

More information

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for Report No.: 9A042401C2 Page 1 of 36 EN 50121-4: 2006 Product: Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client Trade Name: MOXA Model Number: AWK-5222 Prepared for MOXA Inc. Fl.4, No.135, Lane 235,

More information

Network Analyzer for Low-, Medium- and High-Voltage Networks

Network Analyzer for Low-, Medium- and High-Voltage Networks Technical data Network nalyzer for Low-, Medium- and High-Voltage Networks Model PQ-Box 150 1 Fault detection 1 Evaluation of voltage quality according to EN50160 and IEC61000-2-2 (2-4) 1 FFT nalysis up

More information

Microphones & Accessories

Microphones & Accessories Accessories of the KLIPPEL R&D and QC SYSTEMs (Document Revision1.15) FEATURES Microphones optimal for research, development and manufacturing of transducers Condenser and electret microphones High performance/cost

More information

EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009

EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009 CE TEST REPORT Report Number : ETLE080219.157.1 Report issue date: August 21, 2009 Model / Serial No. : NSD-S360 / NONE Multiple Model Name : NSD-S300, NSD-S230, NSD-S680, NSD-H350, NSD-S330, NSD-S370,

More information

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks GB Technical data Issue 06/2009 PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks Fault detection Evaluation of voltage quality according to EN50160 and IEC61000-2-2 Fault recorder

More information

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America World-Wide 3-phase Input Voltage Range (nom. 200 Vrms to 480 Vrms), PF > 0.94 High Power Density 16 W/in 3 94% Typical Efficiency Parallel Operation up to 16 Units (50.4 kw) Cold-Plate Cooling System -25

More information

Immunity Testing for the CE Mark

Immunity Testing for the CE Mark Immunity Testing for the CE Mark Summary The European Union (EU) currently has 25 member countries with 2 additional countries to be added in 2007. The total population at that time will be nearly a half

More information

NEAR FIELD MEASURING MEASURING SET-UP. LANGER E M V - T e c h n i k

NEAR FIELD MEASURING MEASURING SET-UP. LANGER E M V - T e c h n i k MEASURING SET-UP NEAR FIELD MEASURING The measurement of near fields to 6 GHz directly on electronic modules aids in the reduction of disturbance emission. Near field probes measurement setup-0513pe 2

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation Annex to declaration accreditation (scope accreditation) Locations where activities are performed under accreditation Location Abbreviation/ location code Head Location Vijzelmolenlaan 5 & 7 3447 GX oerden

More information

CXE880 FIBRE OPTIC NODE

CXE880 FIBRE OPTIC NODE Kari Mäki 29.4.2015 1(6) CXE880 FIBRE OPTIC NODE The CXE880 is a fibre deep optical node. It is designed for cases where high performance and cost effectiveness are a demand. Requirements of future networks,

More information

Report on the EMC Testing. For. Exception EMS Ltd. RBK-ILS Processor. Report No. TRA A. 29 th April 2016

Report on the EMC Testing. For. Exception EMS Ltd. RBK-ILS Processor. Report No. TRA A. 29 th April 2016 Report on the EMC Testing For Exception EMS Ltd On RBK-ILS Processor Report No. TRA-028046-36-00A 29 th April 2016 RF657 7.0 Report Number: Copy Number: TRA-028046-36-00A PDF REPORT ON THE EMC TESTING

More information

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-89486194-805 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances,

More information

TEST REPORT. Report Number: DAL-001 Project Number: G Report Issue Date: February 6, 2013

TEST REPORT. Report Number: DAL-001 Project Number: G Report Issue Date: February 6, 2013 TEST REPORT Report Number: 100943193DAL-001 Project Number: G100943193 Report Issue Date: February 6, 2013 Product Designation: Standards: Vibrating Fork Level Switch Model: RS85 CENELEC EN 61326-1*BEI

More information

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan 4322705.50 EMC Test report for Plug-in adaptor Models PM1W-IT, PM1WU2-IT, PM1W-GR, PM1W-SP, PM1W-RS, PM1WB-RS, PM1WU2-GR, PM1WU2-SP, PM1WU2-RS, PM1WBU2-RS, PM1W-UK, PM1WU2-UK, PM1W-FR, PM1WU2-FR Guangzhou,

More information

Telecom Test System. Lightning Tests

Telecom Test System. Lightning Tests Lightning Tests Telecom Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................

More information

R&S IMS Hardware Setup according IEC / EN (radiated immunity) Products: R&S IMS, R&S NRP-Z91, HL046E. Application Note

R&S IMS Hardware Setup according IEC / EN (radiated immunity) Products: R&S IMS, R&S NRP-Z91, HL046E. Application Note Products: R&S, R&S NRP-Z91, HL046E R&S Hardware Setup according IEC / EN 61000-4-3 (radiated iunity) Application Note This application note describes the general setup and required equipent for EMC easureents

More information

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz INSTRUCTION MANUAL ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A 20 Hz 1 MHz INSTRUCTION MANUAL THIS INSTRUCTION MANUAL AND ITS ASSOCIATED INFORMATION IS PRO- PRIETARY. UNAUTHORIZED REPRO- DUCTION IS FORBIDDEN.

More information

HEC-30/35LTA-33TDAA Rev A

HEC-30/35LTA-33TDAA Rev A A. Features High Efficiency (Up to 86%). Active Power Factor Correction (Typical 0.95). Isolation Class II All-Round Protection: OVP/SCP/OTP/OPP. Fully isolated metal case with IP20 and dry location. 1-10V,

More information

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A EMC Test Report Applicant: Address of Applicant: Trade Name: FATEK AUTOMATION CORP. 26FL, NO.29, SEC.2, JUNGJENG E. RD., DANSHUEI DIST., NEW TAIPEI CITY, TAIWAN, R.O.C. FATEK Equipment Under Test: Training

More information

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

Doc. EA Model Number:

Doc. EA Model Number: VPS-030AAC Series / VPS-030AAC 030AAC Highlights & Features VPS-030AAC05, 12, 15, 24 Meet DOE Level VI & ErP 2017 Low touch current. Suitable for type BF applications Detachable AC plug with multiple country

More information

TE W Single Output External Power Test & Measurement/Industrial Series

TE W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 120W of AC-DC Power Universal Input 90-264Vac Input Range IPX-2 Rated Enclosure for protection against liquid

More information

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en T10FS Torque Flange Data Sheet Special features Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm, 10 knvm Nominal speed from 12,000 rpm to 24,000 rpm Low rotor weights

More information

TEST REPORT IEC or ISO Reference Number(s) Title of the IEC or ISO Standard(s)

TEST REPORT IEC or ISO Reference Number(s) Title of the IEC or ISO Standard(s) IECEE OD-2020-F7:2017 IEC 2017 Ed.1.0 EMC TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REPORT IEC or ISO Reference Number(s) Title of the IEC or ISO Standard(s) Report Number....

More information

TEST REPORT. Information technology equipment

TEST REPORT. Information technology equipment TEST REPORT Information technology equipment Report Reference No.... 272750TRFEMC Tested by G. Bazzi (project handler)... (name, function and signature)... Approved by G. Curioni (name, function and signature)...

More information

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI and EU CoC Tier 2 Requirements No load input power Average Efficiency Up to 60W of AC-DC Power Universal Input 90-264Vac Input Range Meets Heavy Industrial Levels

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

R&S ZNC Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests Harmonizing the ANSI-C12.1(2008) EMC Tests Subcommittee 1 (Emissions) Subcommittee 5 (Immunity) Joint Task Force on C12.1 June 17, 2013 1 The Accredited Standards Committee C63 presents Harmonizing the

More information

By order of American Power Conversion Holdings Inc. at New Taipei, Taiwan. Author : Harry Deng Reviewed : Tim Yan Pages : 53 pages Annex : NIL

By order of American Power Conversion Holdings Inc. at New Taipei, Taiwan. Author : Harry Deng Reviewed : Tim Yan Pages : 53 pages Annex : NIL 4338754.50 EMC Test report for Multiple Protable Socket-outlets with SPD Models PM5-GR, PM5-RS, PM5-SP, PM5-UK, PM5U-GR, PM5U-RS, PM5U-UK, PM5U-SP, PM5V-GR, PM5V-RS, PM5V-SP, PM5V-UK, PM5T-GR, PM5T-RS,

More information

CXE180 UNIVERSAL AMPLIFIER

CXE180 UNIVERSAL AMPLIFIER Kari Mäki 20.9.2012 1(6) CXE180 UNIVERSAL AMPLIFIER The CXE180 is a compact dual output amplifier. It has two gain modes in one product. Gain can be selected on the field according to wanted operation.

More information

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 The following information was submitted and identified by/on behalf of the client as: Applicant : Ningbo Shanhuang Electric Appliance

More information

Methods for Testing Impulse Noise Tolerance

Methods for Testing Impulse Noise Tolerance Methods for Testing Impulse Noise Tolerance May,6,2015 Larry Cohen Overview Purpose: Describe some potential test methods for impulse noise tolerance What we will cover in this presentation: Discuss need

More information

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.

More information

Electricity Meter Test System

Electricity Meter Test System Component Tests Electricity Meter Test System System Overview.................... 3 Features & Benefits................... 4 Standards....................... 6 Application Options................... 7

More information

PHV RO High Voltage Passive Probe. Instruction Manual

PHV RO High Voltage Passive Probe. Instruction Manual PHV 1000-3-RO High Voltage Passive Probe Instruction Manual Copyright 2012 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 14 to 18 December EMC standards

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 14 to 18 December EMC standards Training Course on Conformity and Interoperability, Tunis-Tunisia, from 14 to 18 December 2015 EMC standards Presented by: Karim Loukil & Kaïs Siala Kaim.wakil@cert.mincom.tn Kais.siala@cert.mincom.tn

More information

CXE202 UNIVERSAL AMPLIFIER

CXE202 UNIVERSAL AMPLIFIER Broadband Cable Networks / Kari Mäki November 23, 2006 1(7) CXE202 UNIVERSAL AMPLIFIER The CXE202 is a dual output amplifier. It has two gain modes in one product. Gain can be selected on the field according

More information

CXE202 UNIVERSAL AMPLIFIER

CXE202 UNIVERSAL AMPLIFIER Broadband Cable Networks / Kari Mäki June 14, 2010 1(7) CXE202 UNIVERSAL AMPLIFIER The CXE202 is a dual output amplifier. It has two gain modes in one product. Gain can be selected on the field according

More information

AA SERIES (1 x 1 Package) Up to 30 Watt DC-DC Converter

AA SERIES (1 x 1 Package) Up to 30 Watt DC-DC Converter FEATURES Industry standard footprint (1 inch X 1 inch) Regulated Outputs, Fixed Switching Frequency Up to 90 Efficiency Low No Load Power Consumption Designed for use without tantalum capacitors -40 C

More information

CXE101 DISTRIBUTION AMPLIFIER

CXE101 DISTRIBUTION AMPLIFIER Broadband Cable Networks / Kari Mäki February 9, 2006 1(5) CXE101 DISTRIBUTION AMPLIFIER The CXE101 is a compact distribution amplifier. It is having all the modern features in flexible format. The important

More information

for Issued for Supremevalue Technology CO., Ltd 4/F,A4 Bldg.,Yinlong Industrial Park,292# Shenshan Rd,518116, Longgang District,Shenzhen,China.

for Issued for Supremevalue Technology CO., Ltd 4/F,A4 Bldg.,Yinlong Industrial Park,292# Shenshan Rd,518116, Longgang District,Shenzhen,China. EMC TEST REPORT for Product: Car Charger Trade Mark: MEKNIC Model: SV-PC01,SV-PC02,SV-PC03,SV-PC04,SV-PC05, SV-PC06,SV-PC07,SV-PC08,SV-PC09,SV-PC10, SV-PC11,SV-PC12,SV-PC13,SV-PC14,SV-PC15, SV-PC16,SV-PC17,SV-PC18,SV-PC19,SV-PC20

More information

CXE180 UNIVERSAL AMPLIFIER

CXE180 UNIVERSAL AMPLIFIER Kari Mäki 14.6.2010 1(5) CXE180 UNIVERSAL AMPLIFIER The CXE180 is a compact dual output amplifier. It has two gain modes in one product. Gain can be selected on the field according to wanted operation.

More information

AC3200 INTELLIGENT BROADBAND AMPLIFIER

AC3200 INTELLIGENT BROADBAND AMPLIFIER Kari Mäki 7.4.2015 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both

More information

C E R T I F I C A T I O N

C E R T I F I C A T I O N C E R T I F I C A T I O N Applicant Address Manufacturer Address : American Power Conversion Holding Inc. Taiwan Branch : 3F., No. 205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan R.O.C.

More information

AC1000 AMPLIFIER & OPTICAL NODE PLATFORM

AC1000 AMPLIFIER & OPTICAL NODE PLATFORM Broadband Cable Networks / Kari Mäki February 6, 2008 1(11) AC1000 AMPLIFIER & OPTICAL NODE PLATFORM The AC1000 is a single active output amplifier with 29 or 39 of platforms. Both platforms can be used

More information

Network Analyzer for Low-, Medium- and High-Voltage Networks

Network Analyzer for Low-, Medium- and High-Voltage Networks Technical data Network nalyzer for Low-, Medium- and High-Voltage Networks Model PQ-Box 100 1 Fault detection 1 Evaluation of voltage quality according to EN50160 and IEC61000-2-2 (2-4) 1 Fault recorder

More information

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer

More information

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz Data Sheet MG3740A Analog Signal Generator 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz Contents Definitions, Conditions of Specifications... 3 Frequency... 4 Output Level... 5 ATT Hold...

More information

TEST REPORT. Power Spout PLT V. tested to the specification

TEST REPORT. Power Spout PLT V. tested to the specification EMC Technologies (NZ) Ltd PO Box 68-307 Newton, Auckland 1145 New Zealand Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT Power Spout PLT 100

More information

AC2000 AMPLIFIER PLATFORM

AC2000 AMPLIFIER PLATFORM Broadband Cable Networks / Kari Mäki June 26, 2008 1(6) 2000 AMPLIFIER PLATFORM The 2000 is a dual active output amplifier with 2 x 39 of gain. The input and output amplifier stages are both based on high

More information

CXE100 DISTRIBUTION AMPLIFIER

CXE100 DISTRIBUTION AMPLIFIER Broadband Cable Networks / Kari Mäki April 5, 2005 1(5) CXE100 DISTRIBUTION AMPLIFIER The CXE100 is a compact distribution amplifier. It is having all the modern features in flexible format. The important

More information

HEC-70LCN-350TDAF Rev B

HEC-70LCN-350TDAF Rev B A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Up to 0.96). Isolation Class II. All-Round Protection: OVP/SCP/OPP Fully isolated metal case with IP20 and dry location. Class 2

More information

Downloaded from 1. THE FOLLOWING PAGES OF MIL-STD-462D HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED:

Downloaded from  1. THE FOLLOWING PAGES OF MIL-STD-462D HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED: NOTICE OF CHANGE METRIC 10 April 1995 MILITARY STANDARD MEASUREMENT OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS TO ALL HOLDERS OF : 1. THE FOLLOWING PAGES OF HAVE BEEN REVISED AND SUPERSEDE THE PAGES

More information

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans LCL Series SIngle Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs form 12 V to 48 V 3 Year Warranty The LCL series is a low cost chassis

More information

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS SYNTHESIZED SIGNAL GENERATOR MG3641A/MG3642A 12 khz to 1040/2080 MHz NEW New Anritsu synthesizer technology permits frequency to be set with a resolution of 0.01 Hz across the full frequency range. And

More information

Center for Quality Engineering. Test Report No.: B0JA0002

Center for Quality Engineering. Test Report No.: B0JA0002 DAT-P-002/91-02 Center for Quality Engineering Test Report No.: Order No.: B0JA Pages: 10 Munich, Sep 12, 2008 Client: Infineon Technologies AG OP TTR RPT 2 Equipment Under Test: Manufacturer: Task: Test

More information

ARCO 400. Technical Data

ARCO 400. Technical Data Technical Data OMICRON electronics GmbH 2017. All rights reserved. This technical data was extracted from the following manual: ENU 1119 04 03 All rights including translation reserved. Reproduction of

More information

HEC-45LTN-45PFAS Rev A

HEC-45LTN-45PFAS Rev A A. Features High Efficiency (Up to 85%). Active Power Factor Correction (Typical 0.96). Isolation Class II. All-Round Protection: OVP/SCP/OPP. Fully isolated plastic case with IP20 and dry location. Class

More information

AC500 AMPLIFIER PLATFORM

AC500 AMPLIFIER PLATFORM Broadband Cable Networks / Kari Mäki March 18, 2004 1(6) AC500 AMPLIFIER PLATFORM The AC500 is a single active output amplifier with 39 of gain. The amplifier can be used as in distribution purposes in

More information

TETRIS User's Guide. High Impedance Active Probe DO177-1

TETRIS User's Guide. High Impedance Active Probe DO177-1 TETRIS 1500 High Impedance Active Probe User's Guide DO177-1 TETRIS 1500 Copyright 2010 Ltd. All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

Current Clamp. 210

Current Clamp. 210 Our range of devices includes clamp meters for measuring current leaks, AC and DC current, voltage, power, resistance, continuity, capacitance or frequency. Some clamp meters have a clearly arranged display

More information

CE EMC Test Report. (Declaration of Conformity) For. Electromagnetic Interference. Prepared for. Eaglerise Electronics (Foshan) Co., Ltd.

CE EMC Test Report. (Declaration of Conformity) For. Electromagnetic Interference. Prepared for. Eaglerise Electronics (Foshan) Co., Ltd. Page 1 of 63 CE EMC Test Report (Declaration of Conformity) For Electromagnetic Interference Of Product: LED Power Supply Trade Name: Model Number: EBP012C****CS ( **** is for the output current and represents

More information

MB120S 120W Single Output Medical Series

MB120S 120W Single Output Medical Series Features 2 x 4 x 1.25 Package, Ideal for 1U Applications 10-year Life design with Premium E-Caps 100 Watts convection cooled Class B Conducted and Radiated EMI performance BF Isolation Type Rated Designed

More information

CE/EMC TEST REPORT. For. Noron Ltd.

CE/EMC TEST REPORT. For. Noron Ltd. Product Name: Trademark: Model Number: Prepared For: Address: Prepared By: CE/EMC TEST REPORT NVR Noron, Videokernel, Huatu For Noron Ltd. HTNR-5004L-P4 HTNR-5004-P4, HTNR-5004-P4-I, HTNR-5008-P8, HTNR-5008-P8-I,

More information

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max. TMT Series, 10 to 50 Watt Features Ultra compact, fully encapsulated plastic case Single-, dual- and triple output models 2 package styles: - with screw terminal block for chassis mount - with solder pins

More information

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H): 065APS18 B Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

EMC Precompliance Systems and Accessories Catalog

EMC Precompliance Systems and Accessories Catalog EMC Precompliance Systems and Accessories Catalog Agilent 84115EM EMC precompliance systems Agilent E7402A and E7405A EMC precompliance analyzers Agilent E7415A EMC measurement software Agilent EMC precompliance

More information

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE Digital Panel Meter K3TE Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display with

More information

EMC TEST REPORT Model: 053-EMC-TR_ING, rev. 12 del 15/05/08. Laboratory identification: L.E.M. S.r.l. UNI CEI EN ISO/IEC EMC Laboratory

EMC TEST REPORT Model: 053-EMC-TR_ING, rev. 12 del 15/05/08. Laboratory identification: L.E.M. S.r.l. UNI CEI EN ISO/IEC EMC Laboratory L.E.M. S.r.l. Notified Body (ID 2034) EMC TEST REPORT Model: 053-EMC-TR_ING, rev. 12 del 15/05/08 Laboratory identification: L.E.M. S.r.l. UNI CEI EN ISO/IEC 17025 EMC Laboratory recognized by Ministry

More information

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE FOR TESTS ACCORDING TO... > ANSI/IEEE C37.90 > ANSI/IEEE C62.41 > EN 61000-4-10 > EN 61000-4-12 > EN 61000-4-18 > IEC

More information

Reducing Uncertainty in EMC Measurements

Reducing Uncertainty in EMC Measurements Reducing Uncertainty in EMC Measurements Uncertainty In general, a standardized EMC test must be developed such that reproducible results are obtained if different parties perform the same test with the

More information