TK 100 Probe Calibrator. Instruction Manual

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "TK 100 Probe Calibrator. Instruction Manual"

Transcription

1 TK 100 Probe Calibrator Instruction Manual

2

3 Copyright 2013 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are subject to change without notice. Manufacturer PMK Mess- und Kommunikationstechnik GmbH Königsteiner Str Bad Soden, Germany Internet: Tel: +49 (0) Fax: +49 (0) Warranty PMK GmbH warrants this oscilloscope accessory for normal use and operation within specifications for a period of two (2) years from date of shipment and will repair or replace any defective product which was not damaged by negligence, misuse, improper installation, accident or unauthorized repair or modification by the buyer. This warranty is applicable only to defects due to material or workmanship. PMK GmbH disclaim any other implied warranties of merchantability or fitness for a particular purpose. PMK GmbH will not be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of use or data, interruption of business and the like), even if PMK GmbH has been advised of the possibility of such damages arising from any defect or error in this manual or product. 3

4 WEEE/ RoHS Directives TK 100 (EC conformity marking) This electronic product is classified within the WEEE/ RoHS* category list as monitoring and control equipment (category 9). Category 9 products are exempted from the restrictions under the scope of the RoHS directive. Your help and efforts are required to protect and keep clean our environment. Therefore return this electronic product at the end of its life either to the manufacturer or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste! * EC Directives: WEEE Directive 2002/96/EC - Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC - Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment 4

5 Safety Information TK 100 To avoid personal injury and to prevent fire or damage to this product or products connected to it, review and comply with the following safety precautions. Be aware that if you use this instrument in a manner not specified the protection this product provides may be impaired. Only qualified personnel should use this instrument. Warning: Dangerous voltages capable of causing death are present when using this instrument. Use extreme caution when handling, testing and adjusting. Connect and disconnect properly. Connect the probe output to the measurement instrument before connecting the probe to the generator. Disconnect the probe from the generator before disconnecting the probe from the measurement instrument. Keep away from live circuits. Avoid open circuitry. Do not touch connections or components when power is present. Do not operate with suspected failures. Refer to qualified service personnel. Indoor use only. Do not operate in wet/damp environment. Keep product surfaces dry and clean. Do not operate the product in an explosive atmosphere. Do not modify the instrument. 5

6 About the TK 100 Probe Calibrator TK 100 The TK 100 facilitates DC to HF adjustment of high voltage probes. Mode of operation The function of TK 100 can be seen from the circuit principle. A stabilized 100 V DC source loads a 1 uf capacitor. A "none chatter contact" connects the voltage to a RC network of approx. 50 Ω and 47 pf. The rise time between 10% and 90% is approx 5 ns. The duration of the square wave pulse is approx 6 ms. For optimum results the HV-probe or divider should be connected coaxial. Picture 1: circuit principle none chatter contact ca. 50 Ohm OUTPUT 100 V 1 µf 47 pf How to use this instrument 1. Connect probe calibrator to the power supply. 2. Connect the probe to the BNC jack. 3. Adjust oscilloscope to the probe divider ratio and set the oscilloscope to 20 V/Div. 4. Connect the power supply to the outlet, the red LED will indicate that the unit is turned on. 5. Adjust probe. 6

7 Specifications TK 100 Square wave output voltage : +100 V ± 0.5% Rise time : < 6 ns Over shot : < 3% Repetition rate : 100 Hz Power Supply Input: Output: US-Version: V AC, 50 Hz/60 Hz (Order-No INT) EU-Version: V AC, 50 Hz/60 Hz (Order-No ) 15 V DC >= 0.3 A Connector DC Line connector with 2.1 mm diameter hole and 5.5 mm outer diameter ø 2.1 ø 5.5 7

8 Probes and accessories TK 100 Since 1991 PMK GmbH Germany manufactures oscilloscope probes and accessories for a wide variety of test and measurement applications. For further information please visit our web site M Revision E - March 2013

TETRIS User's Guide. High Impedance Active Probe DO177-1

TETRIS User's Guide. High Impedance Active Probe DO177-1 TETRIS 1500 High Impedance Active Probe User's Guide DO177-1 TETRIS 1500 Copyright 2010 Ltd. All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

PHV RO High Voltage Passive Probe. Instruction Manual

PHV RO High Voltage Passive Probe. Instruction Manual PHV 1000-3-RO High Voltage Passive Probe Instruction Manual Copyright 2012 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

TA MHz oscilloscope probe TA MHz oscilloscope probe

TA MHz oscilloscope probe TA MHz oscilloscope probe TA375 100 MHz oscilloscope probe TA386 200 MHz oscilloscope probe User's Guide X1 X10 TA386 X1/X10 Max. 600 Vp Introduction This passive high-impedance oscilloscope probe is suitable for most oscilloscopes

More information

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

BumbleBee. High Voltage Differential Probe Ord.-No: Features: High Voltage Differential Probe Ord.-No: 880-102-501 Features: 2000 V rms Measurement Category I, 6000 V transient Overvoltage 1000 V CAT III 400 MHz Bandwidth < 1 % Deviation within Specified Operating

More information

PML 711A-RO High impedance passive probe Features:

PML 711A-RO High impedance passive probe Features: High impedance passive probe Features: 2.5 mm Diameter Tip CeramCore TM Hybrid Probe Coaxial Design Interchangeable Spring Contact Tip IC Contacting System 0.5 to 1.27 mm pitch PMK introduces a new universal

More information

Operator s Manual. PP016 Passive Probe

Operator s Manual. PP016 Passive Probe Operator s Manual PP016 Passive Probe 2017 Teledyne LeCroy, Inc. All rights reserved. Unauthorized duplication of Teledyne LeCroy documentation materials is strictly prohibited. Customers are permitted

More information

Operator s Manual. PP022 Passive Probe

Operator s Manual. PP022 Passive Probe Operator s Manual PP022 Passive Probe 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000, Fax: (845) 578 5985 teledynelecroy.com PP022 Passive Probe Instruction Manual 2017 Teledyne

More information

Pen Multimeter. Model

Pen Multimeter. Model Pen Multimeter Model 381626 CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. This instrument is a 3200 count pen style digital

More information

netzerotools.com 374/375/376 Users Manual Clamp Meter

netzerotools.com 374/375/376 Users Manual Clamp Meter 374/375/376 Clamp Meter Users Manual Fluke 376 True RMS AC DC Clamp Meter Fluke 374 True RMS AC / DC Clamp Meter Fluke 373 True RMS AC Clamp Meter Fluke 375 True RMS AC / DC Clamp Meter LIMITED WARRANTY

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i310s AC/DC Current Clamp Instruction Sheet Introduction The i310s Current Clamp ( Clamp ) has been designed for use with oscilloscopes and digital multimeters for accurate nonintrusive measurement of

More information

CSM-S USER S MANUAL TRIGGER DISTRIBUTION MODULE Release April 7, VXI Technology, Inc.

CSM-S USER S MANUAL TRIGGER DISTRIBUTION MODULE Release April 7, VXI Technology, Inc. CSM-S-11056 TRIGGER DISTRIBUTION MODULE USER S MANUAL 82-0051-000 Release April 7, 2003 VXI Technology, Inc. 2031 Main Street Irvine, CA 92614-6509 (949) 955-1894 bus 2 VXI Technology, Inc. www.vxitech.com

More information

374/375/376 Clamp Meter

374/375/376 Clamp Meter 374/375/376 Clamp Meter Users Manual PN 3608883 July 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks

More information

ELECTROSURGICAL UNIT ANALYZER

ELECTROSURGICAL UNIT ANALYZER ELECTROSURGICAL UNIT ANALYZER ESU-2000A USER MANUAL BC BIOMEDICAL ESU-2000A TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 OVERVIEW... 2 OPERATING INSTRUCTIONS... 3 MANUAL REVISIONS...

More information

User Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. Digital AC/DC Clamp Meter Model 38394 User Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,

More information

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph User Guide AC/DC Mini Clamp Meter Model 380941 Large 3 3/4 digit LCD display with 40 segment bargraph Continuity and Frequency Measurements One touch DCA zero adjust MIN/MAX and Data Hold functions 0.9

More information

PULSE OXIMETRY SIMULATOR

PULSE OXIMETRY SIMULATOR PULSE OXIMETRY SIMULATOR SPO-2000 SYSTEM USER MANUAL BC BIOMEDICAL SPO-2000 SYSTEM TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 LAYOUT... 2 KEYS... 3 LED INDICATORS... 4 OPERATIONS...

More information

MD 200A High voltage differential probe

MD 200A High voltage differential probe 1 MD 200A High voltage differential probe User Manual 601-265B MD 200A High voltage differential probe User Manual MD 200A high voltage differential probe contents 1 Safety terms and symbols 5 2 Safety

More information

ECG PATIENT SIMULATOR FIVE LEAD

ECG PATIENT SIMULATOR FIVE LEAD ECG PATIENT SIMULATOR FIVE LEAD PS-2005 USER MANUAL BC BIOMEDICAL PS-2005 TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 LAYOUT... 2 MANUAL REVISIONS... 6 LIMITED WARRANTY... 6 SPECIFICATIONS...

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand

More information

ECG PATIENT SIMULATOR SIX LEAD

ECG PATIENT SIMULATOR SIX LEAD ECG PATIENT SIMULATOR SIX LEAD PS-2006 USER MANUAL BC BIOMEDICAL PS-2006 TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 LAYOUT... 2 MANUAL REVISIONS... 6 LIMITED WARRANTY... 6 SPECIFICATIONS...

More information

8472B Crystal Detector. Operating and Service Manual

8472B Crystal Detector. Operating and Service Manual 8472B Crystal Detector Operating and Service Manual Part number: 08472-90022 Printed in USA Print Date: May 2001 Supersedes: April 1999 Notice The information contained in this document is subject to change

More information

INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX. Section Page Contents

INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX. Section Page Contents INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX Section Page Contents 1.0............................. 2......................... Description 2.0.............................

More information

AT Advanced Wire Tracer. Users Manual

AT Advanced Wire Tracer. Users Manual AT-1000 Advanced Wire Tracer Users Manual AT-1000 Advanced Wire Tracer English Users Manual AT1000_Rev001 2008 Amprobe Test Tools. All rights reserved. Limited Warranty and Limitation of Liability Your

More information

1.5µm PbSe Power Detector

1.5µm PbSe Power Detector 1.5µm PbSe Power Detector User Guide (800)697-6782 sales@eotech.com www.eotech.com Page 1 of 7 EOT 1.5-5µm PbSe POWER DETECTOR USER S GUIDE Thank you for purchasing your 1.5-5µm PbSe Power Detector from

More information

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS, INC PD5-RM-B PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2. Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 www.spectradynamics.com

More information

Electrical Multimeter

Electrical Multimeter 113 Electrical Multimeter Instruction Sheet Safety Information A Warning statement identifies hazardous conditions and actions that could cause bodily harm or death. A Caution statement identifies conditions

More information

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER: A V T E C H E L E C T R O S Y S T E M S L T D. N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P.O. BOX 265 OGDENSBURG, NY U.S.A. 13669-0265 TEL: 888-670-8729 (USA & Canada)

More information

N2792A and N2793A Differential Probes User s Guide

N2792A and N2793A Differential Probes User s Guide N2792A and N2793A Differential Probes User s Guide Copyright Agilent Technologies 2009 All Rights Reserved. Contents Inspecting the Probe 3 Cleaning the Probe 3 Handling the Probe 3 N2792A and N2793A Differential

More information

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz USER manual Falco Systems WMA-100 High Voltage Amplifier DC - 500kHz Falco Systems WMA-100, High Voltage Amplifier DC - 500kHz High voltage: 20x amplification up to +175V and -175V output voltage with

More information

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2. TA043 100 MHz x10/x100 Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2 031 CAT III, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING

More information

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers DA560D COMPACT SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers Preparation Please read entire manual before installation. Due to the technical nature of amplifiers, it is highly recommended

More information

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE LNFR-100E OPERATING MANUAL SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2. Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 www.spectradynamics.com

More information

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions DGPS Receiver A101 Version: V3.20150602 3030246900-02-EN Read and follow these operating instructions. Keep these operating instructions in a safe place for later

More information

374/375/376. Calibration Manual. Clamp Meter

374/375/376. Calibration Manual. Clamp Meter 374/375/376 Clamp Meter Calibration Manual December 2010 2010 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer User's Guide Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer EX810 AC Clamp meter EX820 True RMS AC Clamp meter EX830 AC/DC True RMS Clamp meter Patented Introduction Congratulations on your

More information

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers DA604D DA954D DA501D DA801D COMPACT SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers Preparation Please read entire manual before installation. Due to the technical nature of amplifiers, it

More information

Keysight N2771B 30 kv High Voltage Probe

Keysight N2771B 30 kv High Voltage Probe Keysight N2771B 30 kv High Voltage Probe User s Guide Notices Keysight Technologies, Inc. 2012-2015 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

FRYCORDER Power Cord Burn-in Generator

FRYCORDER Power Cord Burn-in Generator FRYCORDER Power Cord Burn-in Generator Made in USA FRYCORDER Power Cord Burn-in Generator Copyrights & Trademarks Copyright Hagerman Audio Labs 0. All rights reserved. No part of this document may be photocopied,

More information

INSTRUCTIONS MODELS AVX-TRR-SQMELF TEST JIG FOR USE WITH AVTECH AVR-EB4-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

INSTRUCTIONS MODELS AVX-TRR-SQMELF TEST JIG FOR USE WITH AVTECH AVR-EB4-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER: A V T E C H E L E C T R O S Y S T E M S L T D. N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P.O. BOX 265 OGDENSBURG, NY U.S.A. 13669-0265 TEL: 888-670-8729 (USA & Canada)

More information

BROADBAND'LINEAR'AMPLIFIER Model&F10AD

BROADBAND'LINEAR'AMPLIFIER Model&F10AD BROADBAND'LINEAR'AMPLIFIER Model&F10AD DUAL'CHANNEL & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & ±100V&185mA& 10x& DC&to&ca&1&MHz & HIGH&SLEW&RATE& LOW&OUTPUT&IMPEDANCE & 400&V/µs&

More information

Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR

Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR Safety Information Read and understand this Instruction Manual completely before using this instrument. Failure to observe the warnings and

More information

GPS-701-GGL and GPS-702-GGL

GPS-701-GGL and GPS-702-GGL GPS-701-GGL and GPS-702-GGL USER GUIDE OM-20000117 Rev 2 September 2013 The GPS-701-GGL and GPS-702-GGL are active antennas designed to receive signals from the GPS and GLONASS satellites as well as L-Band

More information

Radio System Strobe Wizard Plus Freemask

Radio System Strobe Wizard Plus Freemask Radio System Strobe Wizard Plus Freemask User manual Translation of the original German user manual Doc. No.: 900.0509.00 Version: 09/2017 Contents Information about this manual and about the manufacturer...

More information

Broadband Step-Up Transformer. User Manual

Broadband Step-Up Transformer. User Manual Broadband Step-Up Transformer User Manual 990-1930 09/2004 Introduction Introduction About this unit The APC Step-Up Transformer provides 220 V power from 60 VAC Broadband cable systems. Safety Electrical

More information

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) 3-349-878-03 1/3.16 Opening the Instrument / Repairs The instrument may only be opened by authorized, trained personnel

More information

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information 36 / True RMS Clamp Meter Instruction Sheet P Read First: Safety Information To ensure safe operation and service of the meter, follow these instructions: Avoid working alone so assistance can be rendered.

More information

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc. User s Guide RP5600 Passive Probe July 2010 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered trademark

More information

CIRCUIT-TEST ELECTRONICS

CIRCUIT-TEST ELECTRONICS USER'S MANUAL Sweep Function Generator with Counter SWF-8030 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY INFORMATION...page 3 INTRODUCTION... 4 SPECIFICATIONS... 5 FRONT PANEL

More information

GPS-703-GGG and GPS-703-GGG-N

GPS-703-GGG and GPS-703-GGG-N GPS-703-GGG and GPS-703-GGG-N USER GUIDE GM-14915086 Rev 4 April 2014 The GPS-703-GGG and GPS-703-GGG-N are active antennas designed to operate at the GPS L1 frequency at 1575.42 MHz, the GPS L2 frequency

More information

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers XPR522 XPR540 XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers Preparation Please read entire manual before installation. Due to the technical nature of amplifiers, it is highly recommended

More information

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721 9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT Model 90721 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ

More information

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS 10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS The Analog / Digital PWM controller allows you to control the speed of a motor, brightness of a lamp or other device using an analog

More information

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein. 15 Planer Stand Model 96316 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo,

More information

USER GUIDE. WR284 Waveguide TRL Calibration Kit GHz. Models: WR284C30\32 Series (Rev A) 03/16

USER GUIDE. WR284 Waveguide TRL Calibration Kit GHz. Models: WR284C30\32 Series (Rev A) 03/16 USER GUIDE WR284 Waveguide TRL Calibration Kit 2.60 3.95 GHz Models: WR284C30\32 Series 8770-512 (Rev A) 03/16 USER GUIDE WR284 Waveguide TRL Calibration Kit 2.60 3.95 GHz Models: WR284C30\32 Series Warranty

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output Voltage 4 Outputs to 1000 Vdc 4 Fully Programable Outputs 4 Single and Dual Outputs 4 Wide Input Ranges (10-20Vdc, 18-36Vdc) 4 1000 Vdc Output Isolation 4 Continuous

More information

Instruction Manual. Manual de instrucciones. Guide d utilisation ET PMET Rev 808

Instruction Manual. Manual de instrucciones. Guide d utilisation ET PMET Rev 808 Instruction Manual Manual de instrucciones Guide d utilisation ET2025 PMET2025-8 Rev 808 www.arrowfastener.com GENERAL SAFETY RULES WARNING! Read all instructions. Failure to follow all instructions listed

More information

INSTRUCTIONS MODEL AVX-S1-P2-EX1 PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER:

INSTRUCTIONS MODEL AVX-S1-P2-EX1 PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER: A V T E C H E L E C T R O S Y S T E M S L T D. N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P.O. BOX 265 OGDENSBURG, NY U.S.A. 13669-0265 TEL: 888-670-8729 (USA & Canada)

More information

Single Phase Rectifier Bridge, 1.2 A

Single Phase Rectifier Bridge, 1.2 A Single Phase Rectifier Bridge, 1.2 A FEATURES VS-1KAB-E Series Ease of assembly, installation, inventory High surge rating Compact Material categorization: For definitions of compliance please see www.vishay.com/doc?99912

More information

STAFF User Manual. Manual Part #

STAFF User Manual. Manual Part # STAFF User Manual Manual Part # 030-00085-00 Introduction Congratulations on the purchase of your new STAFF Secondary Fault Locator. The STAFF is specially designed to detect conductor to earth/ground

More information

Important Safety Information

Important Safety Information USER MANUAL Important Safety Information Before using Zuma R300, please be sure to read all operating instructions carefully. Read, follow, and keep these instructions. Heed all warnings. Do not expose

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

BAS19-V / 20-V / 21-V

BAS19-V / 20-V / 21-V Small Signal Switching Diodes, High Voltage BAS19-V / 20-V / 21-V Features Silicon Epitaxial Planar Diode Fast switching diode in case SOT-23, especially suited for automatic insertion. e3 These diodes

More information

902 FC. HVAC True-rms Clamp Meter

902 FC. HVAC True-rms Clamp Meter 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 902 FC HVAC True-rms Clamp Meter PN 4748982 December 2015 2015 Fluke Corporation.

More information

Agilent 8473B/C Crystal Detector. Operating and Service Manual

Agilent 8473B/C Crystal Detector. Operating and Service Manual Agilent 8473B/C Crystal Detector Operating and Service Manual Agilent Part Number: 08473-90003 Printed in USA Print Date: June 2001 Supersedes: May 1990 Notice The information contained in this document

More information

P331-2 set ESD generator (IEC )

P331-2 set ESD generator (IEC ) User manual Probe set set ESD generator (IEC 61000-4-2) Copyright January 2017 LANGER GmbH 2017.01.09 User manual Table of contents: Page 1 ESD generator (IEC 61000-4-2) 3 1.1 Design and function of the

More information

Non-amplified High Speed Photodetectors

Non-amplified High Speed Photodetectors Non-amplified High Speed Photodetectors User Guide (800)697-6782 sales@eotech.com www.eotech.com Page 1 of 6 EOT NON-AMPLIFIED HIGH SPEED PHOTODETECTOR USER S GUIDE Thank you for purchasing your Non-amplified

More information

Portable HF Magnetic Loop Antenna System Model HF-315

Portable HF Magnetic Loop Antenna System Model HF-315 Portable HF Magnetic Loop Antenna System Model HF-315 Contents: Introduction... 2 Safety information... 3 Warranty information... 4 Assembling and using your antenna... 5 Illustrations... 6 Specifications...

More information

XPA2100 XPA4100 XPA6100. XPA SERIES INSTALLATION/OWNER S MANUAL Mobile Power Amplifiers

XPA2100 XPA4100 XPA6100. XPA SERIES INSTALLATION/OWNER S MANUAL Mobile Power Amplifiers XPA2100 XPA4100 XPA6100 XPA SERIES INSTALLATION/OWNER S MANUAL Mobile Power Amplifiers XPA SERIES INSTALLATION Preparation Please read entire manual before installation. Due to the technical nature of

More information

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz INSTRUCTION MANUAL CALIBRATED IMPULSE GENERATOR MODEL CIG-25 10 khz 1 GHz INSTRUCTION MANUAL THIS INSTRUCTION MANUAL AND ITS ASSOCIATED INFORMATION IS PROPRIETARY. UNAUTHORIZED REPRODUCTION IS FORBIDDEN.

More information

Models 110, 111 & 112

Models 110, 111 & 112 Models 110, 111 & 112 True RMS Multimeters Users Manual November 2000 (English), Rev 1 7/01 2000-2001 Fluke Corporation. All rights reserved. Printed in USA Limited Warranty and Limitation of Liability

More information

CSM_G7S-_-E_DS_E_7_1

CSM_G7S-_-E_DS_E_7_1 Relays with Forcibly Guided Contacts G7S-@-E CSM_G7S-_-E_DS_E_7_ Relays with Forcibly Guided Contacts and High Switching Capacity of A Relays with forcibly guided contacts (EN525 Class A, certified by

More information

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression WORLD-BEAM QS8AFF00 Sensors with Foreground Suppression Datasheet Compact sensors featuring extended range and foreground suppression mode Exceptional optical performance; up to 00 mm sensing range in

More information

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter AM-520 HVAC Multimeter AM-530 True-rms Electrical Contractor Multimeter Users Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com

More information

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806 Series 500 Analog Transmitters by Data Industrial Data Industrial Owner s Manual Data Industrial 2/95 PN 72806 Table of Contents Introduction... 1 4-20 ma Loop Supply Requirements... 2 Installation...

More information

INSTALLATION MANUAL CTM-VESA

INSTALLATION MANUAL CTM-VESA INSTALLATION MANUAL CTM-VESA Premier Mounts 3130 E. Miraloma Avenue Anaheim, CA 92806 Phone: (800) 368-9700 Fax: (800) 832-4888 mounts@mounts.com www.mounts.com IN-CTMVESA.R1 PBL-110 Projector Mount Page

More information

TIA-952 Optical/Electrical Converter. Operating Instructions

TIA-952 Optical/Electrical Converter. Operating Instructions TIA-952 Optical/Electrical Converter Operating Instructions Terahertz Technologies Inc.169 Clear Road Oriskany NY 13424 (315) 736-3642 FAX (315) 736-4078 E-mail sales@terahertztechnologies.com 2/2012 Contents

More information

A-16D A-Net Distributor

A-16D A-Net Distributor A-16D A-Net Distributor For use with the Personal Monitor Mixing System Information in this document is subject to change. All rights reserved. Copyright 2003 Aviom, Inc. Printed in USA Document Rev. 1.03

More information

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode General-purpose Relay CSM_G2R-_-S_(S)_DS_E 3 Slim and Space-saving Power Plug-in Relay Reduces wiring work by 60% when combined with the P2RF-@-PU Push-In Plus Socket (according to actual OMRON measurements).

More information

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com INSTRUCTION MANUAL DLM2 Introduction The DLM2 is designed to measure light levels in foot-candles or

More information

Part Ordering code Marking Remarks BAV99-V BAV99-V-GS18 or BAV99-V-GS08 JE Tape and Reel

Part Ordering code Marking Remarks BAV99-V BAV99-V-GS18 or BAV99-V-GS08 JE Tape and Reel Small Signal Switching Diode, Dual Features Fast switching speed High conductance Surface mount package ideally suited for automatic insertion Connected in series Lead (Pb)-free component Component in

More information

10 Ton Pull Back Ram

10 Ton Pull Back Ram 10 Ton Pull Back Ram Model 97207 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the

More information

High Temperature InfraRed Thermometer with Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer User s Manual High Temperature InfraRed Thermometer with Laser Pointer MODEL 42545 42545 Introduction Congratulations on your purchase of the Model 42545 IR Thermometer. The 42545 is capable of non-contact

More information

LX Series Part-Sensing Light Screen

LX Series Part-Sensing Light Screen Datasheet For Sensing Small or Flat Parts at High Speeds Emitter and receiver pair produce a strobed web of modulated light beams, in 8 lengths, 2 sensing ranges Simple, economical and highly reliable

More information

Bulk Current Injection Probe Test Procedure

Bulk Current Injection Probe Test Procedure Bulk Current Injection Probe Test Procedure 1 TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 TEST METHODS 6 SAFETY 8 FIGURES 9 FORMULAS 12 MAINTENANCE 13 WARRANTY 14 2 INTRODUCTION CURRENT PROBE

More information

SPLIT.CONVERTER. User's Manual. Version 2.0

SPLIT.CONVERTER. User's Manual. Version 2.0 SPLIT.CONVERTER User's Manual Version 2.0 Copyright All rights reserved. Permission to reprint or electronically reproduce any document or graphic in whole or in part for any reason is expressly prohibited,

More information

600A Clamp Meters w/tightsight Display

600A Clamp Meters w/tightsight Display V 750V #61-764 #61-766 #61-768 600A Clamp Meters w/tightsight Display Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CAT.IV 600V CAT.III 1000V 600A 61-766

More information

The elysia team wishes you great delight and compression deluxe with your new mpressor 500.

The elysia team wishes you great delight and compression deluxe with your new mpressor 500. mpressor 500 The compressor from the future The mpressor 500 brings the heritage of our extremely powerful rack mount mpressor into the 500 series format. Like its bigger brother, the mpressor 500 combines

More information

WORLD-BEAM QS18AF Sensor with Background Suppression

WORLD-BEAM QS18AF Sensor with Background Suppression WORLD-BEAM QS8AF Sensor with Background Suppression Datasheet Compact sensors featuring extended range and background suppression mode Exceptional optical performance; up to 00 mm sensing range in compact

More information

AC 3. Active Antenna Combiner. Instruction manual

AC 3. Active Antenna Combiner. Instruction manual AC 3 Active Antenna Combiner Instruction manual Contents Contents Important safety instructions... 2 The AC 3 active transmitter combiner... 4 Delivery includes... 4 Operating controls... 5 Block diagram...

More information

14 Piece Slide Hammer and Puller Set

14 Piece Slide Hammer and Puller Set Owner s Manual & Safety Instructions Save This This Manual Keep Keep this this manual manual for for the the safety safety warnings warnings and and precautions, assembly, assembly, operating, inspection,

More information

Instruction Manual. P6015A 1000X High Voltage Probe

Instruction Manual. P6015A 1000X High Voltage Probe Instruction Manual P6015A 1000X High Voltage Probe 070-8223-04 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless

More information

BROADBAND'LINEAR'AMPLIFIER Model&F20AD

BROADBAND'LINEAR'AMPLIFIER Model&F20AD BROADBAND'LINEAR'AMPLIFIER Model&F20AD DUAL'CHANNEL & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & ±150V&150mA& 20x& DC&to&ca&1&MHz & HIGH&SLEW&RATE& LOW&OUTPUT&IMPEDANCE & 400&V/µs&

More information

50 Ω Dummy Load for Transmitter testing and experiments

50 Ω Dummy Load for Transmitter testing and experiments 50 Ω Dummy Load for Transmitter testing and experiments Many thanks for purchasing this dummy load, it has been designed to provide constant 50 Ω impedance to a radio transmitter to allow off air tests

More information

Model CC4041. CC Series Amplifier. Installation and Use Manual

Model CC4041. CC Series Amplifier. Installation and Use Manual BASS 0 TREBLE 0-12 +12-12 +12 INPUT 1 INPUT 2 INPUT 3 INPUT 4 PEAK SIGNAL POWER POWER CC Series Amplifier Model CC4041 Installation and Use Manual 2012 Bogen Communications, Inc. All rights reserved. Specifications

More information

FR FAMILY MB91460 PULSE FREQUENCY MODULATOR 32-BIT MICROCONTROLLER APPLICATION NOTE. Fujitsu Microelectronics Europe Application Note

FR FAMILY MB91460 PULSE FREQUENCY MODULATOR 32-BIT MICROCONTROLLER APPLICATION NOTE. Fujitsu Microelectronics Europe Application Note Fujitsu Microelectronics Europe Application Note MCU-AN-300065-E-V10 FR FAMILY 32-BIT MICROCONTROLLER MB91460 PULSE FREQUENCY MODULATOR APPLICATION NOTE Revision History Revision History Date 2008-06-05

More information

MANUAL METAL SHRINKER/STRETCHER

MANUAL METAL SHRINKER/STRETCHER MANUAL METAL SHRINKER/STRETCHER Model 95062 ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd.,

More information

Agilent G1888 Network Headspace Sampler

Agilent G1888 Network Headspace Sampler Agilent G1888 Network Headspace Sampler Safety and Regulatory Information Agilent Technologies Notices Agilent Technologies, Inc. 2004 No part of this manual may be reproduced in any form or by any means

More information

PNP. 5 to 800 mm sensor to reflector distance on BRT-60x40C NPN

PNP. 5 to 800 mm sensor to reflector distance on BRT-60x40C NPN Datasheet Coaxial polarized retroreflective sensor for clear object detection Reliable detection of clear, translucent, or opaque objects including PET and glass containers, transparent films, and mirror-like

More information

CEC VIBRATION TRANSMITTER

CEC VIBRATION TRANSMITTER CEC 1-808 VIBRATION TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com E-mail:

More information