Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

Size: px
Start display at page:

Download "Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator"

Transcription

1 Operating Instructions /11.09 METRAVOLT 7A Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator CAT IV GMC-I Messtechnik GmbH Südwestpark Nürnberg Germany Phone Fax

2 Test electrodes (under protective covers) 2 LED display for voltages (> 50 V) and polarity 3 LED for phase test and phase sequence test 4 Moving-iron measuring element for exact voltage indication 5 LCD indicator for voltages of more than 24 V, phase test and phase sequence test 6 Name plate 7 Accessible electrode for phase test and phase sequence test (rear) 8 Key for LED display (2) and measuring element (4) Meaning of symbols on the instrument Warning concerning a point of danger! (Attention: observe documentation!) Indicates CE conformity VDE testing authority approval mark This device may not be disposed of with the trash. 2 GMC-I Messtechnik GmbH

3 Table of Contents Page 1 Application Safety Precautions General Information Testing General Information Testing voltage and polarity Tests with the Accessible Electrode Technical data Maintenance Repair and Replacement Parts Service, DKD Calibration Center and Rental Instrument Service Product Support Application The METRAVOLT 7A is a two-pole voltage tester with LCD indicator, a high-quality moving-iron measuring element and LED display. You can use the METRAVOLT 7A to measure DC and AC voltages in the rated voltage ranges specified on the name plate. Furthermore, you can determine polarity as well as phase and phase sequence. The casing is made of solid rubber and protects the internal measuring element against heavy shocks, water and dust. Thanks to its high degree of protection (IP65) the METRAVOLT 7A may even be used in rain. 2 Safety Precautions The METRAVOLT 7A has been approved by VDE test authorities for application of VDE GS marking. When used for its intended purpose, the safety of the operator, as well as that of the instrument, is assured. GMC-I Messtechnik GmbH 3

4 In order to maintain flawless technical safety conditions, and to assure safe use, it is imperative that you read these operating instructions thoroughly and carefully before placing your instruments into service, and that you follow all instructions contains therein. Observe the following safety precautions: The voltages indicated on the METRA- VOLT 7A are rated voltages. The voltage tester may only be used in systems working with those rated voltage ranges. Faultless indication of values is only guaranteed between -10 C and +55 C. Hold the instrument by the handles only, to avoid covering the display and touching the test electrodes before and during tests. Just before they are used, voltage testers need to be checked to ensure they function correctly. Carry out the function test and check the instrument at a known voltage source - e.g. a 230 V socket. If the display of one or several systems fails in the course of checking, the instrument must not be used again. The METRAVOLT 7A must not be switched on for more than 30 seconds. For the determination of phase conductors and phase sequence by means of the accessible electrode, the perceptibility of the display may be impaired, e.g. when using protection means against direct contact, in unfavourable locations, for example on wooden ladders or insulating floor coverings, as well as in unfavourable lighting conditions and in an improperly grounded AC voltage system. The voltage tester may only be opened by our repair and replacement parts service personnel. Voltage testers must be clean and dry. 4 GMC-I Messtechnik GmbH

5 3 General Information The METRAVOLT 7A is equipped with keys on both sides of its handles with which you switch on the measuring element and the LED display. Without pressing the keys the instrument performs high-resistance tests and while pressing them, low-impedance tests are performed. The specified rated voltage ranges refer to the three indicating systems LCD, LED and measuring element. 4 Testing 4.1 General Information Existing voltage is directly displayed on the LCD indicator when the keys are not pressed. You can also determine phase and phase sequence. The measuring element is switched on when you press both keys. The test current becomes low-resistive as a result of the added load. 4.2 Testing voltage and polarity! Attention! The maximum allowable on-time for voltage testing is 30 seconds. Note! The internal resistance of the METRA- VOLT 7A is very high when the keys are not pressed. In extreme cases, indication of inductive or capacitive voltages may occur which disappears when both keys are pressed. AC voltage When both test electrodes are placed on AC voltage within the rated voltage range, a V- symbol is shown on the LCD indicator. When both keys are pressed, the measuring element always indicates the r.m.s. value. In addition, light-emitting diodes signal existing voltages of 50 V or more. Both LEDs light up when AC voltage is present (±). GMC-I Messtechnik GmbH 5

6 DC voltage and polarity When both test electrodes are placed on DC voltage within the rated voltage range, a V- symbol is shown on the LCD indicator. When both keys are pressed, the measuring element indicates the value. In addition, one of the two LEDs signals voltages from 50 V onwards. Polarity is determined as follows: The LED marked + lights up when the test probe marked + is connected to the positive pole. 4.3 Tests with the Accessible Electrode With the accessible electrode (brass button rear under the measuring element), you can perform phase and phase sequence tests. The tests can be carried out with or without the keys pressed.! Attention! While working with the accessible electrode the perceptibility of the display may be impaired (see part 2 Safety Precautions ). Note! Tests performed with the accessible electrode are only possible in systems working with properly grounded AC voltage systems at voltages of at least 165 V to earth. 6 GMC-I Messtechnik GmbH

7 Phase Test The phase conductor is identified by establishing contact between the test electrode marked with +L1 and the conductor and by touching the accessible electrode Pol-L1- Sensor at the same time. If the triangle is shown on the LCD indicator, the conductor is energized. Note! If the other test probe (without + L1) is used during single-pole tests, the V symbol appears on the LCD indicator in addition to the triangle if voltage is applied. Depending on the location (insulated ground), the -symbol may be indicated as well. The symbols additionally indicated are meaningless in this case. Phase sequence test To determine the phase sequence between two phases in the 230/400 V 3-phase system by applying both test electrodes and touching the accessible electrode, proceed as follows: Search for the phase conductors using one pole (see phase test). Apply both test electrodes to two phase conductors (while pressing keys: approx. 400 V is indicated). Touch the accessible electrode with your finger. When phase L1 is applied to the test probe marked + L1, and phase L2 to the other test probe, the triangle lights up if rotation is clockwise. If the triangle does not light up, the direction of rotation is counter-clockwise. Note! If 230 V is indicated instead of 400 V (while pressing keys), the neutral conductor may have been contacted with one of the test probes. A simple way of checking is by exchanging the two test probes and briefly touching the accessible electrode several times. GMC-I Messtechnik GmbH 7

8 5 Technical data Nominal conditions of use Rated voltage range Rated frequency range Input resistance Current V Hz 1 M (57 k with measuring element activated) I S = 0,6 ma (13 ma with measuring element activated) Analog Indicator (Measuring Element) Type moving-iron element class 2.5 Display range V Limit deviation AC/DC: 2.5% with reference to the upper end scale value LCD and LED Indicators 2-pole measurement ( V): V signals that voltage is applied 1-pole measurement with accessible electrode (as from 165 V to earth): signals that phase is applied 2-pole measurement with accessible electrode (as from 165 V to earth): signals clockwise rotation 2 LEDs ( V) 2-pole measurement: LEDs signal voltages of more than 50 V: one LED lights up for DC voltage (also for polarity test), two LEDs light up for AC voltage Electrical Safety Measurement category Surge voltage withstand Test voltage CAT IV 740 V 12 kv 6.0 kv Electromagnetic Compatibility Interference emission/ Interference immunity IEC GMC-I Messtechnik GmbH

9 Ambient Conditions Operating temperatures Relative humidity Elevation C < 85%, no condensation allowed max m Mechanical Design Protection IP65 Extract from table on the meaning of IP codes IP XY (1 st digit X) Protection against foreign object entry IP XY (2 nd digit Y) Protection against the penetration of water 6 dust-tight 5 water jets Housing Impact-resistant, dustproof plastic housing Display cover unbreakable Connector cable between test probes Rubber-insulated flexible cable H07RNF, 1 m Dimensions Test probe with indicator: 274 mm 75 mm 47 mm Weight 460 g 6 Maintenance The METRAVOLT 7A is completely maintenance-free. Nevertheless, we would advise you to observe the following instructions for safe use: The voltage tester should be kept dry and clean. The plastic housing can be cleaned with a cloth dampened with isopropyl alcohol or soapy water. Device Return and Environmentally Compatible Disposal The instrument is a category 9 product (monitoring and control instrument) in accordance with ElektroG (German Electrical and Electronic Device Law). This device is not subject to the RoHS directive. We identify our electrical and electronic devices (as of August 2005) in accordance with WEEE 2002/96/ EG and ElektroG with the symbol shown to the right per DIN EN These devices may not be disposed with the trash. Please contact our service department regarding the return of old devices. GMC-I Messtechnik GmbH 9

10 7 Repair and Replacement Parts Service, DKD Calibration Center* and Rental Instrument Service When you need service, please contact: GMC-I Service GmbH Service-Center Thomas-Mann-Straße Nürnberg Germany Phone Fax This address is only valid in Germany. Please contact our representatives or subsidiaries for service in other countries. * Calibration Laboratory for Electrical Quantities DKD K accredited per DIN EN ISO/IEC 17025:2005 Accredited measured quantities: direct voltage, direct current values, DC resistance, alternating voltage, alternating current values, AC active power, AC apparent power, DC power, capacitance, frequency and temperature 8 Product Support When you need support, please contact: GMC-I Messtechnik GmbH Product Support Hotline Phone Fax support@gossenmetrawatt.com Edited in Germany Subject to change without notice A pdf version is available on the internet 10 GMC-I Messtechnik GmbH

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) 3-349-878-03 1/3.16 Opening the Instrument / Repairs The instrument may only be opened by authorized, trained personnel

More information

Operating Instructions METRA HIT 1A/2A /1.10. Analog Multimeter

Operating Instructions METRA HIT 1A/2A /1.10. Analog Multimeter Operating Instructions METRA HIT 1A/2A Analog Multimeter 3-349-305-15 4/1.10 1 2 3 4 5 8 6 7 1 Common connection for all measuring ranges (instrument earth) 2 METRA HIT 2A: connection for highest current

More information

METRATESTER 5+ Tester for DIN VDE /6.15

METRATESTER 5+ Tester for DIN VDE /6.15 3-348-817-03 15/6.15 Applications Electrical safety testing of electrical equipment: per DIN VDE 0701-0702: 2008 by means of measurement of: Protective conductor resistance Insulation resistance Protective

More information

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14 3-349-813-3 1/9.14 Insulation measurement per EN 61557-2/VDE 413, part 2 Test voltages: 5 V, 1 V, 25 V, 5 V and 1 V Analog display of measured values and limit values Intelligent filter precise and measurement-dependent

More information

MAVOWATT 4 Multifunction Power Meter

MAVOWATT 4 Multifunction Power Meter Operating nstructions MAVOWATT 4 Multifunction Power Meter 3-348-721-02 3/3.04 1 2 A V 3 4 5 6 Figure 1 2 GOSSEN METRAWATT GMBH Operating controls 1 Connection terminals Current, Voltage,, 2 Mirror scale

More information

METRISO 5000 A/AK. High-Voltage Insulation Tester With Battery or Crank Generator Operating Mode. Option Z580A Crank Generator. Operating Instructions

METRISO 5000 A/AK. High-Voltage Insulation Tester With Battery or Crank Generator Operating Mode. Option Z580A Crank Generator. Operating Instructions Operating Instructions METRISO 5000 A/AK High-Voltage Insulation Tester With Battery or Crank Generator Operating Mode 3-348-857-37 11/4.11 Option Z580A Crank Generator 11 8 3 IEC/EN 61557 VDE 0413 1!

More information

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2. 3-349-443-03 3/2.12 Applications Testing for the Electrical Safety of Electrical Medical Devices in Accordance with the German Medical Product Law (MPG) / MDD The test instrument is used for quick and

More information

METRAClip87 and 88 Clamp Multimeters

METRAClip87 and 88 Clamp Multimeters 3-349-795-03 1/7.14 Current and frequency measurement via clamp meter: METRAClip87: 1500 A AC TRMS and 1500 A DC METRAClip88: 2000 A AC TRMS and 3000 A DC Multimeter functions via connector sockets: V

More information

METRAClip85 and 86 Clamp Multimeters

METRAClip85 and 86 Clamp Multimeters 3-349-794-03 1/8.14 Current and frequency measurement via clamp meter: 600 A AC TRMS and 900 A DC (automatic or manual switching) Multimeter functions via connector sockets: V (AC TRMS and DC) up to 1000

More information

Operating Instructions. METRAport 3A /6.09. Analog Multimeter

Operating Instructions. METRAport 3A /6.09. Analog Multimeter Operating Instructions METRAport 3A Analog Multimeter 3-349-303-15 3/6.09 1 11 2 7 3 4 5 6 10 7 9 8 3 4 5 6 1 Scale 2 Cover of battery compartment 3 Connection socket 10 A for the highest current range

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Digital Multimeter E 1018832 Instruction sheet 12/16 SD/UD 1 probe 1a Finger guards 2 Measurement socket 10 A for current measurement in 10-A (positive) 3 Measurement socket COM (negative)

More information

Operating Instructions CAMILLE BAUER METRAWATT METRAOHM /9.97. Low impedance resistance meas. instrument

Operating Instructions CAMILLE BAUER METRAWATT METRAOHM /9.97. Low impedance resistance meas. instrument Operating Instructions METRAOHM 413 Low impedance resistance meas. instrument GOSSEN METRAWATT CAMILLE BAUER 3-348-776-37 2/9.97 V 8 6 5 4 20 200 PE-TEST 7 1 20 200 + /- METRAOHM 413 3 2 10 9 1 Measurement

More information

PROFiTEST C Test Instrument per DIN VDE /8.14

PROFiTEST C Test Instrument per DIN VDE /8.14 3-349-075-03 16/8.14 Testing of Residual-Current Devices (RCDs) Measures contact voltage without tripping the RCCB. Contact voltage relative to nominal residual current is measured with 1 / 3 nominal residual

More information

METRAHIT WORLD. International TRMS Multimeter /2.16. Features

METRAHIT WORLD. International TRMS Multimeter /2.16. Features 3-349-527-03 8/2.16 Resolution: 100 μ, 100 mω, 10 μ, 10 pf, 0.1 Hz Precision temperature measurement ( 50... +800 C) Frequency and duty cycle measurement at 2 to 14 signals up to 1 MHz Capacitance measurement

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Analogue Multimeter Escola 100 1013527 Instruction sheet 12/15 SD/JS 1 Display with mirror scale 2 Slotted screw for zero calibration 3 Calibration trimmer for setting centre zero

More information

METRAHIT WORLD International TRMS Multimeter

METRAHIT WORLD International TRMS Multimeter Operating Instructions METRAHIT WORLD International TRMS Multimeter 3-349-529-03 10/6.17 1 2 3 4 5 6 7 1 21 8 9 2 3 4 5 20 19 18 17 16 15 14 13 10 11 12 Max. 1000 V! 1 Display (LCD) 2 ON / OFF Light Key

More information

AC/DC CLAMP METER USER S MANUAL

AC/DC CLAMP METER USER S MANUAL AC/DC CLAMP METER USER S MANUAL CONTENTS PAGE SAFETY INFORMATION SYMBOL EXPLANATION SAFETY PRECAUTIONS 1 1 2 MAINTENANCE 3 GENERAL DESCRIPTION 4 PANEL DESCRIPTION 4 OPERATING INSTRUCTIONS... 7 SPECIFICATIONS

More information

PROFiTEST C Test Instrument per DIN VDE /11.10

PROFiTEST C Test Instrument per DIN VDE /11.10 3-349-075-03 15/11.10 Testing of Residual-Current Devices (RCDs) Measures contact voltage without tripping the RCCB. Contact voltage relative to nominal residual current is measured with 1 / 3 nominal

More information

METRISO 5000 D-PI Digital High-Voltage Insulation Tester

METRISO 5000 D-PI Digital High-Voltage Insulation Tester 3-349-209-03 9/4.11 Large measuring range from 0.4 M... 1 T Variable test voltages, or in fixed steps of 100V, 250V, 500V, 1.0kV, 1.5kV, 2.0kV, 2.5kV, 5.0kV Polarization index and absorption ratio Voltage

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

SECULIFE HIT METRAHIT X-TRA OUTDOOR TECH PRO BASE TRMS Digital Multimeter

SECULIFE HIT METRAHIT X-TRA OUTDOOR TECH PRO BASE TRMS Digital Multimeter Operating Instructions SECULIFE HIT METRAHIT X-TRA OUTDOOR TECH PRO BASE TRMS Digital Multimeter 3-349-352-03 6/10.08 Standard Equipment Standard Equipment 1 multimeter 1 KS17S measurement cable set 2

More information

MS2030 CAT III 600 V A V AUTO RS232

MS2030 CAT III 600 V A V AUTO RS232 MS2030 AC Digital Clamp Meter User s Manual CAT III 600 V AUTO RS232 A V CONTENTS 1.Introduction...1 2.Safety Information...1 2.1 Precautions...1 2.2 Safety Symbols...3 3. Description...4 3.1 Front Panel...4

More information

METRAHIT T-COM Cable Multimeter for Measurements in Symmetrical Copper Cable Networks

METRAHIT T-COM Cable Multimeter for Measurements in Symmetrical Copper Cable Networks Operating Instructions METRAHIT T-COM Cable Multimeter for Measurements in Symmetrical Copper Cable Networks 3-349-381-03 6/7.15 Standard Equipment Contact Persons Standard Equipment 1 cable multimeter

More information

PHV RO High Voltage Passive Probe. Instruction Manual

PHV RO High Voltage Passive Probe. Instruction Manual PHV 1000-3-RO High Voltage Passive Probe Instruction Manual Copyright 2012 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

High precision measurement system for current and voltage IHC-A/B-RM01/03

High precision measurement system for current and voltage IHC-A/B-RM01/03 Measurement Offset-free and low-noise 16 bit data acquisition system ISA-ASIC Internal sample rate 3,500 Hz Communication Standard RS232- or RS485 interface Advantages Direct measurement on the bus bar

More information

Precipition Sensor with analogue Intensity Output ,

Precipition Sensor with analogue Intensity Output , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021335/11/09 Precipition Sensor with analogue Intensity Output 5.4103.20.041, 5.4103.20.741 ADOLF THIES

More information

CLAMP MULTIMETER METRACLIP 85 ENGLISH. User s manual

CLAMP MULTIMETER METRACLIP 85 ENGLISH. User s manual CLAMP MULTIMETER METRACLIP 85 ENGLISH User s manual Clamp Multimeter METRACLIP 85 English CONTENTS 1 PRESENTATION... 7 1.1 THE SWITCH... 8 1.2 THE KEYS OF THE KEYPAD... 9 1.3 THE DISPLAY UNIT... 10 1.3.1

More information

Operating Instructions. METRAport 40S /1.13. Digital Multimeter

Operating Instructions. METRAport 40S /1.13. Digital Multimeter Operating Instructions METRAport 40S Digital Multimeter 3-349-412-02 4/1.13 1 3 13 12 11 10 9 8 7 2 3 4 5 6 4 5 6 Control Elements 1 LCD 2 Battery compartment cover 3 ma, A connector jack for direct measurement

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function

More information

PKT 512A-RO High Impedance Passive Cable Divider

PKT 512A-RO High Impedance Passive Cable Divider PKT 512A-RO High Impedance Passive Cable Divider Instruction Manual Copyright 2011 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

METRAHIT MULTICAL Multimeter, Calibrator

METRAHIT MULTICAL Multimeter, Calibrator Operating Instructions METRAHIT MULTICAL Multimeter, Calibrator 3-349-566-01 2/12.09 Standard Equipment Scope of Delivery 1 Multimeter, calibrator 1 KS29 measurement cable set 2 Batteries 1 Condensed operating

More information

K1 K2. User's manual AC/DC CURRENT PROBE C H A U V IN A R N O U X AC/DC CURRENT PROBE. 1 mv/ma OFF 300V CAT II

K1 K2. User's manual AC/DC CURRENT PROBE C H A U V IN A R N O U X AC/DC CURRENT PROBE. 1 mv/ma OFF 300V CAT II ON OL AC/DC CURRENT PROBE K1 K2 ON OL 300V CAT II 10 mv/ma OFF C H A U V IN A R N O U X K2 AC/DC CURRENT PROBE 1 mv/ma OFF C H A U V IN A R N O U X K1 AC/DC CURRENT CLAMP E N G L I S H User's manual 1

More information

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual TETRIS 1000 High Impedance Active Probe Instruction Manual Copyright 2015 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of

More information

Multifunction AC/DC Voltage Tester

Multifunction AC/DC Voltage Tester User Manual Multifunction AC/DC Voltage Tester Model 20250-59 THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-59 DS multifunctional voltage tester.indd 1 8/8/2017 1:37:47 PM Introduction The Digi-Sense

More information

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. SAFETY INFORMATION... 1 2. TECHNICAL SPECIFICATIONS... 2 3. PARTS & CONTROLS...

More information

400 MHz Passive High-Voltage Probe R&S RT-ZH

400 MHz Passive High-Voltage Probe R&S RT-ZH Manual 400 MHz Passive High-Voltage Probe R&S RT-ZH11 1409.7737.02 Printed in Germany Test and Measurment Manufacturer ROHDE & SCHWARZ For comprehensive information about Rohde and Schwarz, please visit

More information

30XR-A Professional Digital Multimeter Users Manual

30XR-A Professional Digital Multimeter Users Manual Professional Digital Multimeter Users Manual 99 Washington Street Melrose, MA 076 Fax 78-665-0780 TestEquipmentDepot.com MADE IN TAIWAN PATENTS PENDING www.amprobe.com MIN 5 00 00 0 0 00m 00m 00 0M m M

More information

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology INSTRUCTION MANUAL Auto-Ranging Digital Multimeter er True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE &

More information

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL Ω CONTENTS CONTENTS 1. SAFETY INFORM...1 4.4 Range Transform...10 1.1 Preliminary...1 4.5 Auto Power Off...10 1.2 During use...2 4.6 Preparation For Measurement...11

More information

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS CONTENTS MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 2 1.2 DURING USE 3 1.3 SYMBOLS 5 1.4 MAINTENANCE 6 2. DESCRIPTION 8 2.1 NAMES OF COMPONENTS 9

More information

METRAHIT EXTRA ETECH ESPECIAL EBASE High Resolution TRMS Digital Multimeter

METRAHIT EXTRA ETECH ESPECIAL EBASE High Resolution TRMS Digital Multimeter Operating Instructions METRAHIT EXTRA ETECH ESPECIAL EBASE High Resolution TRMS Digital Multimeter 3-349-456-03 3/10.08 Standard Equipment Standard Equipment 1 multimeter in HC20 hard case 1 KS17S measurement

More information

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

15B+/17B+/18B+ Calibration Manual. Digital Multimeter 5B+/7B+/8B+ Digital Multimeter Calibration Manual April 206 206 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

PHV 1000-RO High Voltage Passive Probe. Instruction Manual PHV 1000-RO High Voltage Passive Probe Instruction Manual Copyright 2014 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

400Amp True RMS AC Clamp Meter + NCV

400Amp True RMS AC Clamp Meter + NCV User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

BENNING. CM7 Electrical Tester. Service Information

BENNING. CM7 Electrical Tester. Service Information BENNING CM7 Electrical Tester Service Information TABLE OF CONTENTS Page Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 Specifications 3 General Specification 3 Voltage Specification

More information

CONTENTS MS2033A. 1.Introduction Safety Information...01

CONTENTS MS2033A. 1.Introduction Safety Information...01 MS2033A AC Digital Clamp Meter User s Manual CAT III 600 V CONTENTS 1.Introduction...01 2.Safety Information...01 2.1 Precautions...02 2.2 Safety Symbols...03 3. Description...04 3.1 Front Panel...04 3.2

More information

Operating Instructions METRA HIT 16I/L/T. Analog Digital Multimeter with Insulation Measurement /5.06

Operating Instructions METRA HIT 16I/L/T. Analog Digital Multimeter with Insulation Measurement /5.06 Operating Instructions METRA HIT 16I/L/T Analog Digital Multimeter with Insulation Measurement 3-348-892-02 9/5.06 METRA HIT 16I/L METRA HIT 16T (1) (5/5a) (2) (3/3a) (4/4a) (5/5b) (2) (3) (6) (8) (8)

More information

Operating Instructions METRAHIT 30M /3.15. Precision Digital Multimeter

Operating Instructions METRAHIT 30M /3.15. Precision Digital Multimeter Operating Instructions METRAHIT 30M Precision Digital Multimeter 3-348-978-02 9/3.15 1 2 3 4 5 6 7 7 8 1 LCD display, see page 3 for description 2 MENU/ON OFF key Menu Operating Mode: Entry acknowledgment

More information

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology ENGLISH INSTRUCTION MANUAL 2000A Digital Clamp Meter True RMS Measurement Technology NON-CONTACT VOLTAGE TESTING INRUSH CURRENT LOW IMPEDANCE DATA HOLD RANGE HOLD AUDIBLE CONTINUITY DIODE TEST CAPACITANCE

More information

POINTAX 6000L2 Point Recorder

POINTAX 6000L2 Point Recorder GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,

More information

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual

More information

METRAHIT T-COM Cable Multimeter for Measurements in Symmetrical Copper Cable Networks

METRAHIT T-COM Cable Multimeter for Measurements in Symmetrical Copper Cable Networks 3-349-379-03 4/11.08 Insulation resistance measurement (test voltage: 100 ) with simultaneous recognition of interference voltage as well as polarity reversal for diode testing Cable symmetry testing with

More information

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954 auto range, true rms ACA LEAKAGE TESTER Model : DL-9954 Your purchase of this ACA LEAKAGE TESTER marks a step forward for you into the field of precision measurement. Although this ACA LEAKAGE TESTER is

More information

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions CONTENTS [1] SAFETY PRECAUTIONS: Before use, read the following safety precautions 2 [2] APPLICATION AND FEATURES 5 [3] NAME OF COMPONENT UNITS 6 [4] DESCRIPTION OF FUNCTIONS 8 [5] MEASUREMENT PROCEDURE

More information

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -

More information

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks Threshold value monitoring Pulse outputs UMG 96L / UMG 96 Universal measurement device Measuring accuracy Energy: Class 2 Current.../1 A,.../5 A Voltage L - N: ± 1 % Networks TN-, TT-Networks 2 digital

More information

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...

More information

Precipitation Monitor ,

Precipitation Monitor , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021197/11/09 Precipitation Monitor 5.4103.10.000, 5.4103.10.700 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no. 20 751 696 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul Slovenia web site: http://www.metrel.si e-mail:

More information

Digital Clamp Meter Model: &

Digital Clamp Meter Model: & Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER Model: Pro95 TRUE RMS MILLIAMP CLAMP METER TABLE OF CONTENTS 1. SAFETY INFORMATION... 1 2. GENERAL SPECIFICATION... 1 3. ELECTRICAL SPECIFICATION... 2 3-1 ACMA MEASUREMENT... 2 3-2 ACA MEASUREMENT...

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-352 The Service Information provides the following information: Precautions and safety information Specifications Basic maintenance (cleaning, replacing

More information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE INSTRUCTION MANUAL Auto-Ranging Digital Multimeter MM400 DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE 600V 10A 40MΩ 2 GENERAL SPECIFICATIONS Klein Tools MM400 is an auto-ranging

More information

Model DIGITAL MULTIMETER

Model DIGITAL MULTIMETER Model 57070 DIGITAL MULTIMETER INSTRUCTION MANUAL SAFETY INFORMATION To ensure safe operation, and in order to exploit to the full the functionality of the meter, please follow the directions in this section

More information

Multifunction Digital

Multifunction Digital MS2009A Multifunction Digital Clamp Meter User Manual 200/600 OFF 2/20 NCV SEL MAX V RAN HOLD OFF MS2009A AC CLAMP METER AUTO MAX C F kmω μmva CONTENTS Safety requirements...1 Safety signs...1 Notes...1

More information

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/ EU and the Electromagnetic Compatibility (EMC)

More information

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B Data Sheet RISH Max-14 Page 1 of 5 Input resistance can be selected for voltage measurements. Direct and alternating voltages from 400m... 600. Direct and alternating currents from 40mA... 10A. Resistance

More information

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE & FREQUENCY

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

LINAX 4000L Continuous-line recorder

LINAX 4000L Continuous-line recorder -48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged

More information

Warning, refer to accompanying documents V CAT II Overvoltage category II device. CSA Canadian Standards Association

Warning, refer to accompanying documents V CAT II Overvoltage category II device. CSA Canadian Standards Association About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter

More information

Fluke and

Fluke and Fluke 1623-2 and 1625-2 GEO Earth Ground Testers Technical Data The new Fluke 1623-2 and 1625-2 GEO Earth Ground Testers offer data storage and download capabilities via USB port. World class accessories

More information

Measure voltage without test leads. Product Highlights

Measure voltage without test leads. Product Highlights Measure voltage without test leads Measure voltage up to 1000 V ac through the open fork, without test lead contact to live voltage. + Without opening covers or removing wire nuts. On wires up to AWG 4/0

More information

MW3105 DIGITAL CLAMP MULTIMETER

MW3105 DIGITAL CLAMP MULTIMETER MW3105 DIGITAL CLAMP MULTIMETER 2 M MW3105 A 01 INTRODUCTION 1.1 - Unpacking and inspection Upon removing your new Digital Clamp Meter from its packing, you should have the following items: 1. Digital

More information

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use http://www.all-sun.com EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL V Read this owners manual thoroughly before use WARRANTY This instrument is warranted to be free from defects in material and workmanship

More information

80i-110s AC/DC CURRENT PROBE

80i-110s AC/DC CURRENT PROBE Table of Contents 3 80i-110s AC/DC CURRENT PROBE Users Manual November 1996 1994, 1996 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Printed in

More information

QUICK SETUP GUIDE SECULIFE HITAM

QUICK SETUP GUIDE SECULIFE HITAM QUICK SETUP GUIDE SECULIFE HITAM The measurement and testing of measuring equipment in the field of medical technology necessitates absolute reliability and a broad range of applications. The SECULIFE

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) PZ 67E User Manual E-463 3-Channel HVPZT Amplifier Release: 1.2.0 Date: 2004-12-07 This document describes the following

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

Sound Level Meter C.A 832

Sound Level Meter C.A 832 Sound Level Meter C.A 832 E N G L I S H User's manual 1 Meaning of the symbol Caution! Please refer to the user s manual before using the instrument. In this manual, the instructions preceded by the above

More information

DMM8900 SERIES USERS MANUAL

DMM8900 SERIES USERS MANUAL DMM8900 SERIES USERS MANUAL WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of one year. Any instrument found defective within one year from the delivery

More information

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13 INSTALLATION MANUAL Model: Smart Analyzer Manufacturer: Smart Impulse Power meter with consumption breakdown by use 03/12/13 Table of contents Table of contents... 2 1. Introduction... 3 2. Installation

More information

Mini Clamp Meter Model:

Mini Clamp Meter Model: Mini Clamp Meter Model: 72-2985 1 CONTENTS Page Number Details 2 What s Included 3 Important Safety Information 3 Technical Specification 4 Product Overview 5 LCD Overview 6 Operation - AC/DC Voltage Measurement

More information

Operator s Manual. PP016 Passive Probe

Operator s Manual. PP016 Passive Probe Operator s Manual PP016 Passive Probe 2017 Teledyne LeCroy, Inc. All rights reserved. Unauthorized duplication of Teledyne LeCroy documentation materials is strictly prohibited. Customers are permitted

More information

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC) User Manual Compact Autoranging Clamp Meters with NIST-Traceable Calibration Models 20250-55 (400 A AC), 20250-56 (400 A AC/DC) THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-55,-56 DS Clamp Meter

More information

KMD-S04 Multímetro de bolsillo

KMD-S04 Multímetro de bolsillo www.grupotemper.com KMD-S04 Multímetro de bolsillo Table of Contents Title Page Overview ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 3 Unpacking Inspection ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 4 Safety Information

More information

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-I-LP-NC 2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand

More information

ProfiScale MULTI Multimeter

ProfiScale MULTI Multimeter 1,5 V 9V 200 mv 600 V 200 ma 1/10 A ProfiScale MULTI Multimeter en Operating instructions BURG-WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany Introduction Want the reassurance of knowing whether current

More information

Installation and Operating Instructions for Phase Demodulator Type _.2

Installation and Operating Instructions for Phase Demodulator Type _.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/EU and the Electromagnetic Compatibility (EMC)

More information

MultiMeter-Pocket CAT III 1000 V

MultiMeter-Pocket CAT III 1000 V 02 10 18 26 34 42 50 58 66 74 82 DE GB NL DK FR ES IT PL FI PT SE AC DC AC DC CAT III 1000 V 90 98 106 114 122 130 138 146 154 162 170 NO TR RU UA CZ EE LV LT RO BG GR ! Read the operating instructions

More information

METRAHIT ISO TRMS Multimeter with Insulation Measurement

METRAHIT ISO TRMS Multimeter with Insulation Measurement 3-349-415-03 3/10.08 Insulation resistance measurement with interference voltage detection, test voltages: 50, 100, 250, 500, 1000 Multimeter with diverse functions (,, F, Hz) TRMS measurements: TRMS AC

More information

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The Frequency Selector Switch How to Use Data Hold Function

More information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL 600A AC Clamp Meter + NCV Model MA610 USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures

More information