Copyright June Nexans
|
|
- Irene Butler
- 6 years ago
- Views:
Transcription
1 Nexans is the worldwide leader in the cable industry, with an industrial presence in 29 countries and commercial activities in 65 countries. Nexans brings an extensive range of advanced copper and optical fiber cable solutions to the infrastructure, industry and building markets. Its cables and systems can be found in every area of people s lives, from telecommunications and energy networks, to handling, buildings, aeronautics, aerospace, shipbuilding, automobiles, medical applications, railways, petrochemicals, etc. Nexans is listed on the Paris Stock Exchange. Industry Activity 170, avenue Jean Jaurès Lyon Cedex 07 - France Phone: 33 (0) Fax: 33 (0) Web: Copyright June Nexans
2 Marine Edition 2005
3
4 Symbols Temperature Admissible ambient temperature for continuous duty operation Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance to chemicals. Fire Performances Fire performance according to: «Flame retardant» IEC «Fire retardant» IEC Category A, B or C «Fire resistant» IEC Smoke-Corrosivity-Toxicity Smoke density, gases corrosivity and toxicity Flexibility Bending Radius R R = n x outer diameter Copyright June Nexans Halogen free Electro Magnetic Interference Cl Br Fl EMI 1
5 Shipboard cables Generalities 1 - Applications Insulation and sheathing materials Certifications Fire performance 6 Page Shipboard cables 5 - Cables Voltage Temperature Page Instrumentation, control and communication cables TX (C) mp - mt* 150/250 (300) V 90 C 8 TX (C) 331 mp - mt* 150/250 (300) V 90 C 10 TX (I) mp - mt* 150/250 (300) V 90 C 12 TX (I) 331mp - mt* 150/250 (300) V 90 C 14 TCX (C) mp - mt* 150/250 (300) V 90 C 16 TCX (C) 331 mp - mt* 150/250 (300) V 90 C 18 TCX (I) mp - mt* 150/250 (300) V 90 C 20 TCX (I) 331mp - mt* 150/250 (300) V 90 C 22 COAXIAL 80 C 24 Profibus 85 C 26 Local Area Network (LAN) FTP cables 60 C (Cat. 5)/40 (Cat.6) 28 Local Area Network (LAN) S-FTP cables 70 C 30 MX 250 V - 0.6/1 kv 90 C 32 FLAMEX Wiring cables 750 V 150 C 34 Multicore 0.6/1 kv 105 C 36 MPRX 150/250 (300) V - 0.6/1 (1.2) kv 90 C 38 MPRX -FLEX 0.6/1(1.2 kv 90 C 42 MPRX /1 (1.2) kv 90 C 44 MPRX -F 0.6/1 (1.2) kv 90 C 46 MPRXCX 150/250 (300) V - 0.6/1 (1.2) kv 90 C 48 MPRXCX -FLEX 0.6/1 (1.2) kv 90 C 52 MPRXCX /1 (1.2) kv 90 C 54 MPRXCX 6/10 (12) kv 90 C 56 MEPRXCX 8.7/15 (17.5) kv 90 C 58 (ETI) TERMINATION 6/10 kv - 8.7/15 kv 90 C 60 Technical information Data cables Power and control cables * mp: multipairs - * mt: multitriples - : registered trade mark 6 - Installation recommendations Electrical data 66 Page 2
6 Letter coding M PR EPR C X T (C) (I) F FLEX Marine XLPE insulation EPR insulation* Bare copper braid Halogen free sheath Telecommunication Control, instrumentation Collective screen Individual screen Flat cable Flexible cable * Note 1: For cable according to IEC and cross section and 4 mm 2, insulation compound is a special Fire Resistant Halogen Free compound. Copyright June Nexans 3
7 1. Application Shipboard cables manufactured by NEXANS are designed for fixed applications on board of ships. The temperature class of insulation material should be at least 10 C higher than the ambient temperature. 2. Insulation and sheathing materials 2-1 Insulation materials NEXANS has selected HF XLPE (Cross Linked PolyEthylene) for shipboard cables insulation up to 6/10kV or HF EPR (Ethylene Propylene Rubber) for higher voltage levels. These materials have excellent mechanical, chemical and electrical characteristics and meet the requirements of IEC (Insulation material properties ). These materials provide very low dielectric losses, thus instrumentation and telecommunication cables have very good information transmission properties. The operating temperature of the conductor is 90 C and 250 C in short-circuit. 2-2 Sheathing materials NEXANS has selected a polyolefin compound for sheathing using thermoplastic material for SHF1 or thermosetting material for SHF2. These materials demonstrate excellent mechanical, chemical properties in both SHF1 or SHF2 versions and meet the requirements of IEC (Sheathing material properties).the SHF2 material is recommended for permanent oil contact. Fire performance of cables sheathed with polyolefin meets the requirements of IEC category A and/or IEC for «Fire Resistant cables». 3. Certifications Quality system NEXANS is certified ISO 9001 by different certification bodies including Det Norske Veritas (D.N.V.) Type approvals Shipboard cables are approved by the following certification bodies. 4
8 Cables designation Voltage American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale TX (C) 150/250V TX (C) /250V TX (I) 150/250V TX (I) /250V TCX (C) 150/250V TCX (C) /250V TCX (I) 150/250V TCX (I) /250V COAXIAL FLAMEX 750V MULTICORES 0.6/1kV MX 250 V 0.6/1kV 150/250V MPRX 0.6/1kV MPRX -FLEX 0.6/1kV MPRX /1kV MPRX -F 0.6/1kV Copyright June Nexans 150/250V MPRXCX 0.6/1kV MPRXCX /1kV MPRXCX 6/10kV MEPRXCX 8.7/15kV 5
9 4. Fire performance NEXANS Research and Developement Department has adopted a program of constant improvement for insulation and sheathing materials. Such constant developments ensure the excellent fire performance characteristics of our cables in withstanding the requirements of IEC standards. Some extracts of which follow. 4-1 Fire retardancy (IEC ) Cables, when installed (laid vertically or horizontally, bunched on cable trays, in cable conduit, pipes or trunking) are potential vectors for fire propagation. NEXANS provides totally fire retardant shipboard cables range meeting the requirements of IEC category A specifications. Test category Volume of Time of flame combustible application (min) (litres/mètres) A 7 40 B 3,5 40 C 1,5 20 Fire retardant test according to the IEC Cat.A - Cables installed in group on a vertical ladder 4-2 Fire resistance (IEC 60331) 6 In case of fire, some security circuits must maintain the power supply for vital safety equipment (emergency ligthing, alarm systems and fire pumps...). To meet such requirements, NEXANS proposes fire resistant cables (MPRX/MPRXCX 331) with mica tape + HF XLPE insulation. These cable types meet IEC specifications (750 C - 90 minutes). More over, Nexans has developped special Fire Resistant Compound to pass IEC test at 1000 C 90 minutes. Fire resistant test according to the IEC 60331
10 4-3 Measurements of combustion gases (IEC / ) The secondary effects of fire often cause greater damage than the fire itself. It is for this reason that NEXANS manufactures shipboard cables with Halogen Free compounds. Smoke density, toxic and corrosive gases released during combustion must be greatly reduced (hydrochloric acid measurement lower than 0.5 %). Test results meet the requirements of IEC / Measurements test equipment of combustion gases according to the IEC / Smoke opacity (/27m 3 Chamber) In case of fire, smoke emissions evolving from cables must be very low. For this reason our shipboard cables are designed to withstand the stringent requirements of -2 and the 27m 3 chamber test developped by the London Transport Executive Research Laboratory. Copyright June Nexans Measurement of smoke opacity - 27m 3 - Chamber 7
11 TX (C) Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Registro Italiano Navale Applications TX (C) type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards TX (C) type withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation XLPE (cross linked polyethylene) 3. Collective screen Alu/Polyester tape with a tinned copper drain wire 4. Outer sheath Polyolefin Colour: orange Marking NEXANS 205 TX (C) «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC IEC IEC IEC Cat. A IEC / Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 8
12 TX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 0.5* x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES TX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 0.75* x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 3 x x 3 x x 3 x x 3 x TX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 1.5* x 2 x x 2 x x 2 x x 2 x x 2 x Copyright June Nexans 2 x 3 x x 3 x Stocked products Products on request *2 pairs are assembled as a quad 9
13 TX (C) 331 Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Design Applications TX (C) 331 type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards TX (C) 331 type meets fire resistant performances, withstands IEC category A fire test on bunched cables and peforms to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C 1 1. Conductor Stranded bare copper class 2 2. Insulation Special Fire Resistant Halogen Free Compound 3. Collective screen Alu/Polyester tape with a tinned copper drain wire 4. Outer sheath Polyolefin Colour: orange Marking NEXANS 205 TX (C) C «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC IEC IEC IEC C IEC Cat. A IEC / Fire resistant IEC C Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 10
14 TX (C) /250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 0.75* x 2 x x 2 x X 2 X x 2 x x 2 x x 2 x INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 2 x 3 x x 3 x x 3 x x 3 x TX (C) /250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 1.5* x 2 x x 2 x x 2 x x 2 x x 2 x x 3 x x 3 x Stocked products Products on request *2 pairs are assembled as a quad Copyright June Nexans 11
15 TX (I) Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Registro Italiano Navale Applications TX (I) type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards TX (I) type withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation XLPE (cross linked polyethylene) 3. Individual screen Alu/Polyester tape with a tinned copper drain wire 4. Outer sheath Polyolefin Colour: orange Marking NEXANS 205 TX (I) «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC IEC IEC IEC Cat. A IEC / Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 12
16 TX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 3 x INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES TX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 3 x x 3 x x 3 x x 3 x x 3 x TX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) Copyright June Nexans 1 x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 3 x x 3 x x 3 x Stocked products Products on request 13
17 TX (I) 331 Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Design Applications TX (I) 331 type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards TX (I) 331 type meets IEC fire resistant performances, withstands IEC category A fire test on bunched cables and peforms to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C 1 1. Conductor Stranded bare copper class 2 2. Insulation Special Fire Resistant Halogen Free Compound 3. Individual screen Alu/Polyester tape with a tinned copper drain wire 4. Outer sheath Polyolefin Colour: orange Marking NEXANS 205 TX (I) C «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC IEC IEC IEC C IEC Cat. A IEC / Fire resistant IEC C Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 14
18 TX (I) /250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 1 x 3 x x 3 x x 3 x x 3 x x 3 x TX (I) /250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 3 x x 3 x x 3 x Copyright June Nexans Stocked products Products on request 15
19 TCX (C) Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Registro Italiano Navale Applications TCX (C) type is used on board of ships in all locations for installations complying with IEC standards For open decks installation, cables have to be covered against UV rays. TCX (C) type withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore,this especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation XLPE (cross linked polyethylene) 3. Separator Polyester tape 4. Armouring Bare copper braid with bare copper drain wire. 5. Outer sheath Polyolefin Colour: orange Marking NEXANS 205 TCX (C)* «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC IEC IEC IEC Cat. A IEC / * except for 1 pair and 1 triple, the cable marking is TCX(I) Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 16
20 TCX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x x 2 x 0.5* x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 3 x INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES TCX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x x 2 x 0.75* x 2 x x 2 x X 2 X x 2 x x 2 x x 2 x x 3 x x 3 x x 3 x x 3 x x 3 x TCX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x x 2 x 1.5* x 2 x x 2 x x 2 x x 2 x x 2 x Copyright June Nexans 1 x 3 x x 3 x x 3 x x 3 x Stocked products Products on request * 2 pairs are assembled as a quad 17
21 TCX (C) 331 Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Applications TCX (C) 331 type is used on board of ships in all locations for installations complying with IEC standards For open deck installation, cables have to be covered against UV rays. TCX (C) 331 type meets IEC 60331fire resistant performances, withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation Special Fire Resistant Halogen Free Compound 3. Separator Polyester tape 4. Armouring Bare copper braid with bare copper drain wire. 5. Outer sheath Polyolefin Colour: orange Marking NEXANS 205 TCX (C) 331 *1000 C «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking * except for 1 pair and 1 triple, the cable marking is TCX(I) Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC IEC IEC IEC C IEC Cat. A IEC / Fire resistant IEC C Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 18
22 TCX (C) /250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x x 2 x 0.75* x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 1 x 3 x x 3 x x 3 x x 3 x x 3 x TCX (C) /250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x x 2 x 1.5* x 2 x x 2 x x 2 x x 2 x x 2 x x 3 x x 3 x x 3 x x 3 x Copyright June Nexans Stocked products Products on request * 2 pairs are assembled as a quad 19
23 TCX (I) Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Registro Italiano Navale Applications TCX (I) type is used on board of ships in all locations for installations complying with IEC standards For open decks installation, cables have to be covered against UV rays. TCX (I) type withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore,this especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation XLPE (cross linked polyethylene) 3. Individual screen Alu/Polyester tape with a tinned copper drain wire 4. Separator Polyester tape 5. Armouring Bare copper braid with bare copper drain wire 6. Outer sheath Polyolefin Colour: orange Marking NEXANS 205 TCX (I) «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC IEC IEC IEC Cat. A IEC / Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 20
24 TCX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES TCX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 3 x x 3 x x 3 x x 3 x TCX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x Copyright June Nexans 2 x 3 x x 3 x Stocked products Products on request 21
25 TCX (I) 331 Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Design Applications TCX (I) 331 type is used on board of ships in all locations for installations complying with IEC standards For open decks installation, cables have to covered against UV rays. TCX (I) 331 type meets IEC fire resistant performances, withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C 1 1. Conductor Stranded bare copper class 2 2. Insulation Special Fire Resistant Halogen Free Compound 3. Individual screen Alu/Polyester tape with a tinned copper drain wire 4. Separator Polyester tape 5. Armouring Bare copper braid with bare copper drain wire 6. Outer sheath Polyolefin Colour: orange Marking NEXANS 205 TCX (I) C «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC IEC IEC IEC C IEC Cat. A IEC / Fire resistant IEC C Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 22
26 TCX (I) /250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x x 2 x x 2 x x 2 X x 2 x x 2 x x 2 x INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 2 x 3 x x 3 x x 3 x x 3 x TCX (I) /250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 3 x x 3 x Copyright June Nexans Stocked products Products on request 23
27 Coaxial Flamex RG Type Approval Certificates Bureau Veritas Applications High Frequency Data transmission (communication equipment, radar, instrumentation equipment). Video sugnal transmission Max conductor temperature: 80 C Design 1. Conductor - Stranded bare, tinned or silvered copper - Bare copper weld for RG Dialectric Plain PE (polyethylene) 3. Fire Barriers (tapes) 4. Screen Single or double braid Braid, tinned or silvered copper 5. Outer sheath Polyolefin Colour: black or green Marking P FLAMEX Cable Type Standards Approved Bureau Veritas MIL C 17 IEC Cat. A IEC / Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 24
28 Coaxial 50 Ω MIL C17 Cable type Stranding Conductor Diam Dielectric Diam Braid Wire Diameter Outer Diameter Weight (kg/km) Operating Voltage FLAMEX RG 58 CU 19 x 0.18 TC ± TC 4.95 ± V FLAMEX RG 174 AU 7 x 0.16 BCw ± TC 2.79 ± V FLAMEX RG 213 U 7 x 0.75 BC ± BC 10.3 ± V FLAMEX RG 214 U 7 x 0.75 SC ± x 0.16 SC 10.8 ± V Coaxial 75 Ω MIL C17 Cable type Stranding Conductor Diam Dielectric Diam Braid Wire Diameter Outer Diameter Weight (kg/km) Operating Voltage DATA CABLES FLAMEX RG 59 BU 1 x 0.57 BCw ± BC 6.15 ± V FLAMEX RG 11 AU 7 x 0.40 TC ± BC 10.3 ± V TC: Tinned copper BC: Bare copper BCw: Bare copper weld SC: Silvered copper Technical Data COAXIAL 50 Ω MIL C17 COAXIAL 75 Ω MIL C17 Capacity (pf/m) <106 <72.2 Velocity (%) Copyright June Nexans 25
29 Type Approval Certificates Certified manufacturer according to ISO 9001 Applications Profibus cables dedicated for fixed installation on board of ship in all rooms below and decks for data technical networks in control units. PROFIBUS 1 x 2 x AWG Ω 4 pairs or 2 x 4 pairs Category 5/6 Max conductor temperature: 85 C Design 1. Conductor Standred bare copper 2. Insulation Irradiated XLPE 3. Overall Screen PETP-Alu-Foil + tinned copper braid 4. Outer sheath Halogen Free Cross linked material Marking NEXANS RHEYHALON Series 991 Profibus 150Ω Core Identification Red-green Standards Factory Standard IEC IEC / IEC Cl Br Fl Flame retardant IEC Low smoke Halogen free IEC No toxicity No corrosivity IEC C + 90 C 26
30 PROFIBUS - 1 x 2 x AWG 24 Electrical and Mechanical characteristics - Loop resistance max. 190Ω - Characteristics impedance 150Ω ± 10% (3 to 20 MHz) - Image attenuation constant max. 5dB/km (at 38.4 khz) max. 3dB/km (at 9.6 khz) - Mutual capacitance max. 35 nf/km (at 800 Hz) - Insulation resistance min. 16GΩ. km (at 20 C) Bending Radius DATA CABLES R - Fixed installation 10 x d - Repeatedely bending 20 x d d= cable diameter Copyright June Nexans 27
31 LAN CABLING Applications Nexans Cabling Solutions has developed the LANmark Maritime Cabling System to support LAN communication onboard ships and on offshore units. It addresses the requirement of the marine industry for performing, highly reliable and ruggedised data networks. The LANmark Maritime product series benefits from advanced copper (LANmark-7 GG45 Maritime) and optical technologies (LANmark-OF) in order to support the deployment of LANs in office and control areas, in accommodation and living quarters as well as in processing and industrial areas. Nexans Cabling Solutions offers an application independent LAN platform that will support the existing as well as the forthcoming LAN technologies such as Ethernet, Gigabit Ethernet, 10Gigabit Ethernet, ATM, fibre channel It also offers the possibility to deploy neighbouring technologies such as CATV for entertainment, voice applications and VoIP. It is also designed to support industrial technologies such as Industrial Ethernet. Design 1. Cable Fully screened 1000 MHz Cat.7 Multimedia or fibre optic 2. Patchpanel 24 connectors GG45 Maritime Cat. 7 vibration proof or Fiber optic, for 19 racks 3. Outlet 2 connectors GG45 Maritime Cat. 7 or Fiber optic For data, voice and multimedia application For indoor or outdoor or industrial areas 4. Consolidation Point Connection of pre-assembled cabins equipement Standards ISO/IEC 11801:2002 EN 50173:2002 Draft ISO/IEC IEC IEC EN Please contact our commercial department for further information about LAN cabling systems: - Copper patchcords - Fibre optic patchcords - Pre-terminated copper and fibre optic cables - Multimedia adapters - Specific link / channel requirements Flame retardant IEC SHF1 Low smoke -2 SHF1 Cl Br Fl Halogen free IEC SHF1 No toxicity SHF1 No corrosivity IEC SHF1-20 C + 70 C EMI 28
32 LAN CABLING - Cable Cables Type Bandwidth Copper LANmark-7 Maritime(*) SHF1 LSFROH S-FTP 1000 MHz 7.9 mm 4 pairs AWG23-70 Kg/km Indoor N10m.002 Copper LANmark-7 Oil & Gas Mud Resistant S-FTP 1000 MHz 8.9 mm 4 pairs AWG23-72 Kg/km Drilling / N10g.002 exposed area Fibre LANmark-OF Tight Buffer 50/125 OM2 Various cores Indoor / Several P/N or OM3 Outdoor Single/Multimode Fiber 9/125 OS1 (*) SHF1 : Fire Performance according to IEC , IEC , IEC , -2 LAN CABLING - Connectors and Couplers Nominal Diameter Conductors Cables Weight Application Part Number INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES Item Type Number of ports Connection Application Part Number Copper LANmark-7 GG45 maritime Connector 24 copper connectors RJ45 - GG45 19 patchpanels N42m.730 Fibre Fibre Optic Coupler 24 LC Duplex or 24 LC Duplex or 19 patchpanels Various 12SCDuplex or 12SCDuplex or 24 MTRJ or 24 ST 24 MTRJ or 24 ST DATA CABLES LAN CABLING - Outlets to be fitted with LANmark-7 Maritime or LANmark-OF connectors Outlet Type Number of ports Dimensions H x W x D Application Part Number Copper & Fibre Wall / Surface mount 50 x 50 mm Metal 2 50 x 50 x 55 mm Indoor N Copper & Fibre Industrial Water/dust tight x 70 x 90 mm Industrial areas N42i.101 Copper & Fibre Din / Rail mount DIN-Rail x 18 x 65 mm Technical cabinets N20i.001 LAN CABLING - Patchpanels to be fitted with LANmark-7 Maritime or LANmark-OF connectors Patchpanel Type Number of ports Copper Vibration Proof 24 copper connectors 1HU x racks N52m001 Fibre Optic Metal / Sliding 24LCDuplex or 12SCDuplex or 24 MTRJ 1HU x 19 x 280 mm 19 racks N Fibre Optic Metal / Sliding 24 ST couplers 1HU x 19 x 280 mm 19 racks N LAN CABLING - Class F Link Performances (ISO / IEC 11801) Dimensions H x W x D Application Part Number Frequency MHz Attenuation db/100m NEXT db ACR db/100m PSNEXTdB LAN CABLING - LANmark - 7 cable Performances (Typical at 20 C) ELFEXT db/100m PSELFEXT db/100m Copyright June Nexans Frequency MHz Attenuation db/100m NEXT db ACR db/100m PSNEXTdB ELFEXT db/100m PSELFEXT db/100m > >
33 Local Area Network (LAN) FTP Cables Applications FTP 100 Ω cables for high rate data transmission at a maximum 155 MHz (Category 5) or 350 MHz (Category 6) frequency including: ATM 155 MBit/s, FDDI/CDDI 100 Mbits, Ethernet 100 Base TX, 100 Base VG, Token Ring 10 Base T, Gigabit Ethernet (Category 6). For use in environment with high signal/noise coefficient. 100 Ω 4 pairs or 2 x 4 pairs Category 5/6 Max conductor temperature: 60 C (Cat. 5) 40 C (Cat. 6) Design 1. Conductor Bare copper (Diam.: 0.52 mm-cat. 5) (Diam.: 0.55 mm-cat. 6) 2. Insulation Foam skin PE (polyethylene) 3. Screen Alu/Polyester tape Tinned copper drain wire 4. Outer sheath Polyolefin Colour: orange Marking FTP «Number of pairs» LSZH LANMark CATEGORY 5/6 EC VERIFIED FF «MM/YY» + Metric Marking Core Identification Pair 1: white/blue Pair 2: white/orange Pair 3: white/green Pair 4: white/brown Standards EN 50173, 50167, ISO/IEC TIA/EIA 568A (Cat. 5), 568B (Cat. 6) IEC IEC / IEC Flame retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C Cat C Cat. 6 EMI 30
34 LOCAL AREA NETWORK (LAN) FTP Cables Dimensional data 4 pairs Cat. 5 2 x 4 pairs Cat. 5 4 pairs Cat. 6 Nominal diameter x LOCAL AREA NETWORK (LAN) FTP Cables Dimensional data Category 5 Frequency (MHz) Standard Attenuation (db 100m) Typical DATA CABLES Category 6 Frequency (MHz) Attenuation (db 100m) Mutual capacitance: nF/km Linear Resistance: Ω/km (Cat.5) and 80Ω/km (Cat.6) Skew: ns/m Propagation Velocity: % Transfer Impedance (at 10 MHz): mω (Cat.5) and 45 mω (Cat.6) Characteristic Impedance: Ohm ± 15Ω Copyright June Nexans 31
35 Applications Local Area Network (LAN) S-FTP Cables S-FTP 100 Ω cables for high rate data transmission at a maximum 100 MHz frequency including: ATM 155 MBit/s, FDDI/CDDI 100 MBits, Ethernet 100 Base TX, 100 Base VG, Token Ring 10 Base T. For use in environment with high signal/noise coefficient 100 MHz, 100 Ω 4 pairs or 2 x 4 pairs Category 5 Max conductor temperature: 70 C Design 1. Conductor Bare copper (Diam.: 0.52 mm) 2. Insulation Foam skin PE (polyethylene) 3. Collective Screen Alu/Polyester tape Tinned copper drain wire + Tinned copper braid 4. Outer sheath Polyolefin Colour: orange Marking S-FTP «Number of pairs» LSZH LANMark CATEGORY 5 EC VERIFIED FF «MM/YY» + Metric Marking Core Identification Pair 1: white/blue Pair 2: white/orange Pair 3: white/green Pair 4: white/brown Standards EN 50173, ISO/IEC TIA/EIA 568A IEC IEC / IEC Flame retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C + 70 C EMI 32
36 LOCAL AREA NETWORK (LAN) S-FTP Cables Dimensional data 4 pairs Cat. 5 2 x 4 pairs Cat.5 Nominal diameter x LOCAL AREA NETWORK (LAN) S-FTP Cables Electrical data Frequency (MHz) ISO/IEC, EN50173 Attenuation (db 100m) Next (db) ACR (db) Standard Typical Standard Typical Standard Typical DATA CABLES Mutual capacitance: nF/km Linear Resistance: Ω/km Skew: ns/m Propagation Velocity: % Transfer Impedance (at 10 MHz): mω Characteristic Impedance: Ohm ± 15Ω Copyright June Nexans 33
37 MX Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale Applications MX type is used on board of ships installations complying with IEC standards and especially for electrical cabling of cabinet or switchboard. MX type withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V 0.6/1(1.2) kv Max conductor temperature: 90 C Design 1. Conductor Flexible bare copper class 5 2. Insulation Polyolefin Colours: red, black, blue, white, green/yellow 1 2 Marking NEXANS 205 MX «voltage» 1 x «Section» mm 2 90C IEC A «year» * * Standards IEC IEC IEC IEC IEC Cat. A IEC / Cl Br Fl Fire retardant IEC Low smoke Halogen free IEC No toxicity No corrosivity IEC to 80 C 34
38 MX 250V (0.75/1 mm 2 ) - 0.6/1kV Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x x x x x x x x x x x x x x Colour of stocked products - MX 250V (0.75/1 mm 2 ) - 0.6/1kV Stocked products Products on request Packaging : - Coil of 100 m for cross-section 16 mm 2 - Cut on request for cross-section 25 mm 2 Cables 1 x x 1 1 x x 2.5 Black Red Blue White Green/Yellow POWER AND CONTROL CABLES 1 x 4 1 x 6 1 x 10 1 x 16 1 x 25 1 x 35 1 x 50 Copyright June Nexans 1 x 70 1 x 95 1 x
39 Type Approval Certificates Bureau Veritas Applications Wiring cable for on-board instrumentation and control equipment. Thin wall insulations and light weight applications. FLAMEX Thin wall wiring cables 750 V Max conductor temperature: 150 C Design 1. Conductor Flexible tinned copper class 5 2. Insulation Halogen free compound 1 2 Marking EX.XX «cross section» «NFF P3» - «production weeks and year» Core Identification FLAMEX /AWG 20: yellow FLAMEX /AWG18: white FLAMEX /AWG16: green FLAMEX /AWG14: yellow FLAMEX /AWG12: white Other colours on request. Standards IEC Cat. C IEC / Cl Br Fl Fire retardant IEC Low smoke Halogen free IEC No toxicity No corrosivity IEC Chemicals Resistances -30 to 150 C 36
40 FLAMEX Wiring cable Cables Gauge AWG Conductor stranding n x Ø Section Min. Outer diameter Nom. Max. Weight approx. (kg/km) FLAMEX x 0.16 TC FLAMEX x 0.20 TC FLAMEX x 0.25 TC FLAMEX x 0.25 TC FLAMEX x 0.30 TC FLAMEX x 0.23 TC FLAMEX x 0.25 TC FLAMEX x 0.25 TC FLAMEX x 0.30 TC FLAMEX x 0.30 TC TC : Tinned Copper (1) FLAMEX 15: maximum operating temperature = +130 C Multicore cables on request. Copyright June Nexans POWER AND CONTROL CABLES 37
41 Multicore Cable Type Approval Certificates Bureau Veritas Lloyd s Register Applications Multicore cable is used on board of ships installations complying with IEC standards and especially for shipboard industry as prefabricated cabin. Multicore cable type withstands the IEC category C, a fire test on bunched cables and performs to the solas requirements. All materials used to manufacture this cable are halogen free. This design ensures that non corrosive and low toxic gases are emiitted in case of fire. 0.6/1 kv Max conductor temperature: 105 C Design 1. Conductor Tinned copper 1.5 mm 2 (37 x 0,223) 2.5 mm 2 (37 x 0,30) 2. Insulation Cross Linked Halogen Free compound 3. Outer sheath Cross Linked TPE Colour: black Marking FLAMEX «n» x «s» G Filotex P EDE «item reference» 0.6/1 kv 105 C + Batch Number Core Identification 3 cores: black - red - green/yellow 5 cores: black - red - blue - black - green/yellow Standards IEC IEC Cat. C IEC / Cl Br Fl Fire retardant IEC Cat. C Low smoke Halogen free IEC No toxicity No corrosivity IEC C C 38
42 MULTICORE CABLE Multicore - 3 G Insulation diameter 2.00 mm - Outer sheath diameter 5.40 mm ± 0.30 mm Multicore - 3 G Insulation diameter 2.45 mm - Outer sheath diameter 6.40 mm ± 0.30 mm Copyright June Nexans POWER AND CONTROL CABLES 39
43 MPRX Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale Applications MPRX type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards MPRX type withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 (Sector-shaped: 70 mm 2 3 cores) 2. Insulation XLPE (cross linked polyethylene) 3. Outer Sheath (Filler if necessary) Polyolefin Colour: black Marking NEXANS 205 MPRX «voltage» «n» x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification 1 core: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blue or green/yellow For the voltage 250 V and from 5 cores and above 0.6/1 kv: white with black printed numbers Standards IEC IEC IEC IEC IEC Cat. A IEC / Cl Br Fl Fire retardant IEC Low smoke Halogen free IEC No toxicity No corrosivity IEC C 40
44 MPRX 150/250 (300) V Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x x x x x x x x MPRX 0.6/1 (1.2)kV Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 5 x x x x x x x x x x x x x x POWER AND CONTROL CABLES Stocked products Products on request Copyright June Nexans 41
45 MPRX 0.6/1 (1.2) kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x x x x x x x x x x x x x x x x x x x x x x x x x x 1.5/2 x E x 2.5/2 x E x x x x x x x x 70 Sect x 95 Sect x 120 Sect x 150 Sect Stocked products Products on request E= green/yellow core 42
46 MPRX 0.6/1 (1.2)kV Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 4 x x x x x x x x x Stocked products Product on request Copyright June Nexans POWER AND CONTROL CABLES 43
47 MPRX -FLEX Type Approval Certificates Lloyd s Register of Shipping Applications MPRX -FLEX type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards MPRX-FLEX using is recommended for installations in narrow space. MPRX -FLEX type withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Flexible bare copper class 5 2. Insulation XLPE (cross linked polyethylene) 3. Outer sheath (Filler if necessary) Polyolefin Colour: black Marking NEXANS 205 MPRX-FLEX 0.6/1 kv «n» x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification 1 cores: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blue or green/yellow 5 cores and above: white with black printed numbers Standards IEC IEC IEC IEC Cat. A IEC / Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivivity IEC C Flexible EMI 44
48 MPRX -FLEX 0.6/1 kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x x x x x x x x x x Products on request Copyright June Nexans POWER AND CONTROL CABLES 45
49 MPRX 331 Type Approval Certificates China Classification Society Bureau Veritas Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale Applications MPRX 331 type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards and in safety circuits, where fire resistance is required. MPRX 331 type meets the IEC fire resistant performances, withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation Cross section mm 2 : Special Fire Resistant Halogen Free Compound 1000 C Cross section 6mm 2 : Mica Tape + XLPE (cross linked polyethylene) (sector shaped 70mm 2 3 cores) 3. Outer Sheath (Filler if necessary) Polyolefin Colour: black Marking NEXANS 205 MPRX 331* 0.6/1kV «n» x «s» 90 C IEC A «WW/YY» * * + Metric Marking * MPRX C for cross section mm 2 Core Identification 1 core: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blueor green/yellow From 5 cores and above: white with black printed numbers Standards IEC IEC IEC IEC C IEC Cat. A IEC / Cl Br Fl Fire resistant IEC C Fire retardant IEC Low smoke Halogen free IEC No toxicity No corrosivity IEC C 46
50 MPRX /1 (1.2) kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x x x x x x x x x x x x x x x x x x x x x x x x x 70 (sect) x 95 (sect) x 120 (sect) x 150 (sect) x x x x x x x x POWER AND CONTROL CABLES 5 x x x x x x Copyright June Nexans 5 x x x x x Stocked products Products on request 47
51 MPRX -F Type Approval Certificates Bureau Veritas Det Norske Veritas Lloyd s Register of Shipping Registro Italiano Navale Applications MPRX -F cable type is used for lighting distribution on board of ships in all public areas complying with IEC standards MPRX -F type withstands the IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation XLPE (cross linked polyethylene) 3. Outer sheath Polyolefin Colour: green Marking NEXANS 205 MPRX F 0.6/1kV 2 x «1.5» + E mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification Black-blue-green/yellow Dimensions 11 x 5 mm permissible current rating in open air: 16 A Standards IEC IEC IEC Cat. A IEC / Cl Br Fl Fire retardant IEC Low smoke Halogen free IEC No toxicity No corrosivity IEC C 48
52 Copyright June Nexans POWER AND CONTROL CABLES 49
53 MPRXCX Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale Applications MPRXCX type is used on board of ships at all levels and open decks for installations complying with IEC standards The good screening qualities of the braid also reduce radio interference and electrical influences to electronic installations. MPRXCX type withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 (Sector-shaped: 70 mm 2 3 cores) 2. Insulation XLPE (cross linked polyethylene) 3. Inner covering (Filler if necessary) Lapped 4. Armouring Bare copper braid 5. Outer sheath Polyolefin Colour: black Marking NEXANS 205 MPRXCX «voltage» «n» x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification 1 cores: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blue or green/yellow For the voltage 250 V and from 5 cores and above 0.6/1 kv: white with black printed numbers Standards IEC IEC IEC IEC IEC Cat. A IEC / Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 50
54 MPRXCX 150/250 (300) V Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x x x x x x x x x MPRXCX 150/250 (300) V Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x x x x x x x x x MPRXCX 0.6/1 (1.2) kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) POWER AND CONTROL CABLES 5 x x x x x x x x x Copyright June Nexans 5 x x x x x x x x x Stocked products Products on request 51
55 MPRXCX 0.6/1 (1.2) kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x x x x x x x x x x x x x x x x x x x x x x x x x x 1.5/2 x E x 2.5/2 x E x x x x x x x x 70 Sect x 95 Sect x 120 Sect x 150 Sect Stocked products Products on request E: Green/Yellow core 52
56 MPRXCX 0.6/1 (1.2)kV Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 4 x x x x x x x x x Stocked products Products on request Copyright June Nexans POWER AND CONTROL CABLES 53
57 MPRXCX FLEX Applications MPRXCX -FLEX type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards MPRXCX-FLEX using is recommended for installations in narrow space. MPRXCX - FLEX type withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Flexible bare copper class 5 2. Insulation XLPE (cross linked polyethylene) 3. Inner covering (Filler if necessary) Lapped 4. Armouring Bare copper braid 5. Outer sheath Polyolefin Colour: black Marking NEXANS 205 MPRXCX-FLEX 0.6/1 kv «n» x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking Core Identification 1 cores: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blue or green/yellow 5 cores and above : white with black printed numbers Standards IEC IEC IEC IEC Cat. A IEC / Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivivity IEC C EMI 54
58 MPRXCX -FLEX 0.6/1 kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x x x x x x x x x x Products on request Copyright June Nexans POWER AND CONTROL CABLES 55
59 MPRXCX 331 Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale Design Applications MPRXCX 331 type is used on board of ships at all levels and open decks for fixed installations complying with IEC standards and in safety circuits, where fire resistance is required. The good screening qualities of the braid also reduce radio interference and electrical influences to electronic installations. MPRXCX 331 type meets the IEC fire characteristics, withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 0.6/1 (1.2) kv Max conductor temperature: 90 C 1 1. Conductor Stranded bare copper class 2 2. Insulation Cross section mm 2 : Special Fire Resistant Halogen Free Compound 1000 C Cross section 6mm 2 : Mica Tape + XLPE (cross linked polyethylene) (sector shaped 70mm 2 3 cores) 3. Inner covering (extruded or lapped) 4. Armouring Bare copper braid 5. Outer sheath Polyolefin Colour: black Marking NEXANS 205 MPRXCX 331* «voltage» «n» x «s» mm 2 90C IEC A «WW/YY» * * + Metric Marking * MPRXCX C for cross section mm 2 Core Identification 1 core: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blue or green/yellow From 5 cores and above: white with black printed numbers Standards IEC IEC IEC IEC C IEC Cat. A IEC / Fire resistant IEC C Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 56
60 MPRXCX /1 (1.2) kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x x x x x x x x x x x x x x x x x x x x x x x x x 70 (sect) x 95 (sect) x 120 (sect) x 150 (sect) x x x x x x x x POWER AND CONTROL CABLES 5 x x x x x x Copyright June Nexans 5 x x x x x Stocked products Products on request 57
61 MPRXCX Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanisher Lloyd Lloyd s Register of Shipping Registro Italiano Navale Applications MPRXCX type is used for fixed installations on board of ships at all levels and open decks. The good screening qualities of the braid also reduce radio interference and electrical influences to electronic installations. MPRXCX type withstands IEC category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 6/10 (12) kv Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Extruded semi-conductor 3. Insulation XLPE (cross linked polyethylene) 4. Screen Extruded semi-conductor Bare copper tape 5. Inner covering Polyolefin 6. Armouring Bare copper braid 7. Outer sheath Polyolefin Colour: red Marking NEXANS 205 MPRXCX 6/10 kv «n» x «s» mm 2 90C IEC A «WW/YY» + Metric Marking Core Identification By coloured thread: blue-white-red Standards IEC IEC IEC IEC Cat. A IEC / Fire retardant IEC Low smoke Cl Br Fl Halogen free IEC No toxicity No corrosivity IEC C EMI 58
SHIPLINK TM to support your performance: cable solutions and services for safety and reliability
SHIPLINK TM to support your performance: cable solutions and services for safety and reliability Symbols Temperature Admissible ambient temperature for continuous duty operation Weather Resistance to
More informationData sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2
Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded
More informationComplete, innovative cables range for shipbuilding industry
Complete, innovative cables range for shipbuilding industry Symbols Temperature Admissible ambient temperature for continuous duty operation Weather Resistance to severe weather conditions Fire Performances
More informationNETWORK CONNECTIVITY SYSTEMS
NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation
More informationInformation technology. Generic cabling systems, General requirements
KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.
More informationData sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft
Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic
More informationShip and Offhsore. Approved cables for ship- and offshoreindustry
Ship and Offhsore Approved cables for ship- and offshoreindustry NEK Kabel AS - Norway. (NEK Sealine Marine products) tel. +47 67 91 21 80 - Firmapost@nek-kabel.no 1 OVER 100 YEARS OF EXPERIENCE 1913-2013
More informationProduct information. Marine, Oil & Gas.
Product information Marine, Oil & Gas www.drakamog.com DRAKA Product information MOG 2010 Draka ShipLine range; the choice for reliability and flexibility For more than 100 years, Draka has met and exceeded
More informationCOPPER + LWL RAW CABLES
COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation
More informationOFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS
OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires
More informationCIR (Crush & Impact Resistant) VFD Power Cable
37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per
More informationData sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft
Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires
More informationInstallation Recommendations
Installation Recommendations Cable pulling recommendations The process of pulling electrical cables on board marine vessels is a relatively standard procedure. Nevertheless, NEXANS would suggest the following
More informationMultimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS
Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION SOLUTIONS COAXIAL CABLES BUILDING MANAGEMENT SYSTEMS BROADCASTING & STUDIO Prysmian Group Linking
More informationMULTIMEDIA & DATA TRANSMISSION
NEXANS, every c a b l e t h a t m a k e s a t r a i n r o l l Whoever you are, rolling stock OEM, subsystem supplier or operator, Nexans provides everything from energy & telecom cable to integrated cabling
More informationIndustrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.
Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001 Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001-10 Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.
More informationFor information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.
Telecommunication and fire alarm cables For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. J-YY Bd 14 J-YY BMK 15 J-Y(St)Y Lg 16 J-Y(St)Y
More informationShip Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4
Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T
More informationTwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm
name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation
More informationA NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES
A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES 2 TABLE OF CONTENTS SHIPBOARD CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENCIAL 5 SHIPBOARD POWER CABLES FlameBlocker KONS 0,6/1 kv 8 FlameBlocker
More informationGEXOL WORLD CLASS OIL & GAS CABLES
GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant
More informationMarine Cables General Catalogue
Marine Cables General Catalogue Marine Cables Special cables for civil and defence ship applications General catalogue Linking the Future As the worldwide leader in the cable industry, Prysmian Group believes
More informationInstall & Go Cat.8 S/FTP Trunk Cable Assembly Description
Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated
More informationMULTIMEDIA CABLE H6091ZHB
CAVEL News MULTIMEDIA CABLE H6091ZHB MULTIMEDIA CABLE H6091ZHB Multimedia is a must in the modern way of life. Growing communication needs in any environment whether at home or the office the connection
More informationCables for data transmission in industrial automation
Cables for data transmission in industrial automation The Quality Connection The LEONI Group Cable expertise for the most various industrial markets. LEONI is a leading supplier of cable systems and related
More informationK20 & L120 LSZH Armoured F/FTP Cat6 Cables
K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE
More informationData sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations
Page 1/7 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable drag chain suitable Cat.6A, 8 pole, X-coded
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 Description: Banana Peel Composite - (2) Cat 5e 4-pair 24 AWG unshielded plus (2) Series 6 Coax with Duobond IV Quad shield, polyolefin insulation on the
More informationUNIRAIL D RS485 and BUS cables
UNIRAIL D RS485 and BUS cables Type: 1x2x22 AWG/7 + 1x22 AWG/7 (1x2x0,35 + 1x0,35) Code: RW103A stranded tinned copper wire 22 AWG/7 (0,35 mm²) white blue POWER ELEMENTS: stranded bare copper wire 22 AWG/7
More informationn 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible
n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...
More informationCables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables
Cables for Data Transmission in Industrial Automation Fieldbus Cables Copper Cables Fibre Optic Cables 2 KERPEN GmbH & Co. KG 2005 2.2006 Printing errors excepted. Subject to alteration. Contents Seite
More informationCoaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums
4.3-10 Coax Serie Coaxial Cables HF Steckverbinder für Mobilfunk-Anwendungen in Bulk Rings or on Cable Drums Coaxial Cables In addition to the wide range of coaxial connectors, Telegärtner offers suitable
More informationArmoured Instrumentation Cables to BS6883
Armoured Instrumentation Cables to BS Low Smoke Zero Halogen Pairs/Triples - Collectively Screened. TAC, EPR, SCRN, SW, GSWB, SW 0/0V Application Armoured control and instrumentation cables for fixed wiring
More informationCUSTOM DESIGN COAXIAL CABLES BY SICAB
CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency
More informationHO7RN-F 450/750V BS EN Highly Flexible Rubber Cable
Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516
More informationInstall & Go Cat.8 STP Trunk Cable Assembly Description
Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated
More informationDetailed Specifications & Technical Data
RFP Specification #17-11125-C, Exhibit 2 Programmable Light Poles for BART Plaza ENGLISH MEASUREMENT VERSION 1502SB Multi-Conductor - Multimedia Control Cable For more Information please call 1-800-Belden1
More informationArmoured Power and Control Cables to BS7917
1 Armoured Power and Control Cables to BS Fire Resistant, TAC. MGT. EPR. ZH. GSWB. SW, 00/00 V. Low Smoke Zero Halogen Application Armoured cables for fixed wiring in ships and offshore units where circuit
More informationVFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE
VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic
More informationEC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s
EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)
More informationEXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)
XTRA GUARD 1 MULTICONDUCTOR, SUPRASHIELD EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE UL TYPE CM, AWM 2464 CSA CMG FT4 300 VOLT 34 CHOOSE XTRA GUARD 1FOR: Unsurpassed Flame and Moisture Resistance
More informationSUPERIOR MARINE CABLE SOLUTIONS
SUPERIOR MARINE CABLE SOLUTIONS FLEXIBLE FINE STRANDED Horizon Maximus II Company Profile Through over 35 years of history and experience, we have built a renowned reputation for supplying superior cables
More informationData sheet OpDAT breakout cable 24x1 OM4 - bend insensitive
Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors
More informationCategory 6 UTP EuroClass C ca Cables
Category 6 UTP EuroClass C ca Cables Datasheet: GD103704v1 APPLICATION Brand-Rex Cat6Plus C6U cables exceed the Category 6 performance standards. They are rated to 250MHz and are suitable for use in all
More informationInstall & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General
Install & Go SMARTen (Cat.6A) STP Trunk General Cat 8 Filler Cat.6A U/FTP Horizontal cables (x6) Fan-Out Cables Cat.6A STP Keystones TRUNK CABLE SECTION VIEW Trunk Isometric Front View RiT s Copper Install
More informationDNVGL-CP-0400 Edition December 2015
CLASS PROGRAMME Type approval DNVGL-CP-0400 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationNexans Industrial Solutions PRODUCT CATALOG
Nexans Industrial Solutions PRODUCT CATALOG i NEXANS BRINGS ENERGY TO LIFE COPPER CABLES Nexans brings energy to life through an extensive range of cables and cabling solutions that deliver increased performance
More informationContent HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...
Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control
More informationVFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS
VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant
More informationCAT 5e UTP Cable: NETSET BOX [305m], indoor
Code: E08_05 CAT 5e UTP Cable: NETSET BOX [05m], indoor NETSET BOX UTP 5e Ethernet cable far exceeds the requirements for Category 5e twisted pair cables. View of the cable box - inside 05m of the cable.
More informationArmoured Power and Control Cables Fire Resistant
Armoured Power and Control Cables Fire Resistant Low Smoke Zero Halogen TAC. MGT. EPR. ZH. GSWB. SW, 00/00V Application Armoured cables for fixed wiring in ships and offshore units where circuit integrity
More informationCaledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:
Caledonian www.caledonian-cables.co.uk www.caledonian-cables.net Profibus L2 Indoor Application: This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the
More informationData sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m
Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12-jack to RJ45-plug Ethernet connection line Cat.5, 4-pole, D-coded (IEC
More informationSUBMERSIBLE PUMP CABLES
12 SUBMERSIBLE PUMP CABLES 1-450 / 750 V Termoplastic rubber, round orflat flexibe cable ACCORDING TO NF C -102 HD 22.4 S2 Water absorption tests: IEC 811.1.3 VDE 0472 Teil 2 NF C -026 HD 505-1-3 s1 Maximum
More informationCommunication, Control, and Industrial Cable
Communication, Control, and Industrial Cable Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 291 Get control of demanding applications T he broad
More informationArmoured Power and Control Cables to BS6883
Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in
More informationRailway products. Edition 2014
Railway products Edition 2014 Bridging our technologies Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components
More informationAddison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:
Addison www.addison-tech.com www.addison-cables.com Profibus SK Indoor + Outdoor Application: The application of these Profibus SK cables are in the cell and field area, just as for conventional types.
More informationTo keep your family safe and protected V-Guard Wires & Cables
The Suraksha Chakra To keep your family safe and protected V-Guard Wires & Cables Efficient Performance For over four decades V-Guard lived up to the reputation of making reliable products that were designed
More informationThe Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock
The Quality Connection Cable and Systems for Rolling Stock Business Unit Rolling Stock Consulting and Sales Cable solutions Phone +41 (0)62-288-8356 Fax +41 (0)62-288-8383 System solutions Phone +49 (0)9172-6844-11
More informationUTP Cat 5e cable (200 MHz) (PVC sheath)
JetLan is the only structured cabling system that includes all the passive components required for the installation or adaptation of your data network, as we include all the different types of high performance
More informationCABLE.
CABLE www.pcnet-cable.com.tw sales@pcnet-cable.com.tw PCnet Leading Your Net! PCnet was founded in 1985 and is a leading manufacturer of netwking industries. We provide a complete range of products f structured
More informationRAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø
RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø Automated Stacking Cranes (ASC) Ship To Shore Container Cranes (STS) Rubber Tyre Gantry (RTG)
More informationCategory 6 A F/FTP Euroclass C ca Cables
Category 6 A F/FTP Euroclass C ca s Datasheet: GD103266v2 APPLICATION The Brand-Rex AC6F/FTP C ca cables are compliant with the European Construction Products Regulation, achieving Euroclass level C ca
More informationOpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram
Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or
More information15 years of experience
Wires and Cables 15 years of experience APS supplies standard and special copper and fiber optic cables based on its 15 years of experience in the sector, 8 of which in designing and manufacturing. Since
More informationRHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813
with / without optical fibre elements 3.6/6 kv Contents: Letter code Construction details and voltage-classes Technical data 1 with / without optical fibre elements Letter code Flexible cables acc. to
More informationContents. Category7 SSTP Solid Indoor Cable - Page 03
Product Catalog Contents Category7 SSTP Solid Indoor Cable - Page 03 Category6A UTP Solid Indoor Cable - Page 04 Category6A Keystone Jack - Page 05 Category6A Unshielded Patch Cord - Page 05 Category6
More informationENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable
ENERGY (N)SHTOEU Low Voltage Reeling Cable Technical Data Type Type designation Approvals/standards Application (N)SHTOEU-J/-O DIN VDE 0250, Part 814; VDE-Reg.-Nr. 7519; GOST R Flexible reeling cable for
More informationData sheet OpDAT connection cable 2x1 OS2 - bend insensitive
Illustrations Principle diagram Page 1/7 Product specification connection cable for direct connector termination with higher robustness cable structure: I-V(ZN)HH2, duplex patch cable with additional outer
More informationTPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT
TPE-INSULATED CABLES Products TPE - Cables TPE-INSULATED CABLES 105 C O N T E N T S C O N T E N T S Page TPE single cores according to DIN 72551, type A 107 TPE single cores according to DIN 72551, type
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 General Description: PTZ (CCTV+Control+Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-22 AWG stranded
More informationCores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.
()TSCGEWOEU TEAX TTS-LWL 3,6/6 kv: Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy and data, for application under high mechanical
More informationCables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :
Power Cables Fire Resistant Cables Distributed By : WILSON CABLES PRIVATE LIMITED 142, Gul Circle, Jurong Industrial Estate, Singapore 629602 Tel : + 65 68617888 Fax : + 65 68617871 E-mail : exports@wilson-cables.com.sg
More informationINDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS
INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C
More informationMarineLine YOZp 0,6/1 kv
Properties Application: Light, armoured, reduced low voltage power cables for power and lighting applications in all ship areas. Characteristics: Class 2 s Light, reduced Halogen free and low smoke, flame
More informationkv: medium voltage reeling cable with fibreoptics
PROTOLO(SMK)-LWL ()TSKCGEWOEU 3,6/6 kv: medium voltage reeling cable with fibre-optics Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy
More informationEXCELLENT ELECTRICAL PERFORMANCES
50OHMS CORRUGATED COPPER TUBE COAXIAL CABLE PRODUCT INTRODUCTION 2 Hansen's manufacturing of wide-scope 50ohms corrugated copper coaxial Cable is the fruitful result of the engineers' diligent research
More informationSpeedflex. Halogen free coaxial cables.
Speedflex Halogen free coaxial cables Speedflex is a completely halogen-free and environmentally-friendly alternative to standard RG coaxial cables. Speedflex Item Material Speedflex Speedflex Speedflex
More informationH155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.
H155A02 Part Number: H155A02 COAX RF H155 FRNC Product Description COAX RF H155 FRNC Product Specifications Application Application 1: Application 2: 50 Ohm low loss coaxial transmission cable designed
More informationWIRE & CABLE. 99 Wire Low fire hazard wire and cable
Applications 99 wire has a dual wall construction of radiation cross-linked modified polyester. This combines excellent mechanical performance and chemical resistance with a range of enhanced fire hazard
More informationPower Cables and their Application
Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,
More informationINTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.
INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn
More informationY-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking
Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation
More informationMedium Voltage Power Cables
N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium
More informationData sheet Patch cord Cat.6 A AWG m yellow
Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification especially suitable for shielded and unshielded class E A systems fully shielded Cat.6 A patch
More informationÖLFLEX HEAT. Cable Solutions for Extreme Temperature
ÖLFLEX HEAT Cable Solutions for Extreme Temperature ÖLFLEX Reliable performance no matter how extreme the temperature. Choosing the best cable for applications involving extreme temperatures is one of
More informationDetailed Specifications & Technical Data
Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics
More informationT E C H N I C A L D A T A for
Page 2 of 33 T E C H N I C A L D A T A for Electrical, Instrumentation and Communication Offshore LIST OF CONTENT: RFXU 0,6/1KV, BLACK SHEATH, UNARMOURED...4 CONSTRUCTION...4 RANGE AND DIMENSIONS RFXU
More informationCopper and Fiber Optic Cables
Copper and Fiber Optic Cables Pietro Nicoletti piero[at]studioreti.it Cables-Engl - 1 P. Nicoletti: see note pag. 2 Copyright note These slides are protected by copyright and international treaties. The
More informationCOMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationAmphenol Cable. Features Allows for mass termination Up to 64 conductors
G80.7mm Economical Flat Ribbon 94V-0 A G80 X X XX X FLAT RIBBON CABLE.7mm Up to 64 conductors VARIATION CODE Blank: Standard PACAGING LENGTH NUMBER OF CONDUCTORS : 500 Feet 09: 9 Position : 400 Feet 4:
More informationDataTwist 5 ScTP Cable
케이블콘 ( 주 ) 기술지원팀 :: 콘넥터문의 0707-3-770 케이블문의 0707-3-7702 N E T W O R K I N G C O P P E R 5.69 DataTwist 5 ScTP Cable TIA/EIA-568-TSB 36, Category 5 Nonbonded-Pair Cables 2 AWG Solid Bare Copper Conductors
More informationSelection table for flat & ribbon cables
Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for flat & ribbon cables www.helukabel.com FLAT & RIBBON
More informationC400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR
C400-UMUM-100 Product Classification Brand Product Series Product Type CNT Jumper with interface types UHF Male and UHF Male, 30.48 m CNT Braided cable assembly General Specifications Body Style, Connector
More informationRHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814
HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents: Letter code Construction details Cross-section and nominal voltages Technical data 2017 RHEYCORD(RTS)
More informationRHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814
HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents: Letter code Construction details Cross-section and nominal voltages Technical data 2017 RHEYCORD
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology
More informationACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation)
ACR (Attenuation to Crosstalk Ratio) The distance between the wanted signal and the interfering signal (ACR) is an important factor for the transmission quality. To ensure a faultless transmission, the
More information