Series 10-ZSE80/10-ISE80

Size: px
Start display at page:

Download "Series 10-ZSE80/10-ISE80"

Transcription

1 Series 0-ZSE80/0-ISE80 RoHS -Color Display Digital Pressure Switch For General Fluids Directional Control Valves For positive 0 80 For vacuum/ compound 80 80F N P B R T S V Rated range Symbol -X50 Clean series 0 to 0 kpa 00 to 00 kpa 0 Piping R/4 0 (M5 female thread) NPT/4 N0 (M5 female thread) G/4 F0 (M5 female thread) C0 Rc/8 URJ/4 B TSJ/4 Piping direction L (bottom ported) is not available. Specifications Lead wire length 3 m Note) Refer to page 35 for detail. Option Option Piping direction Bracket Panel mount Panel mount Front protection cover Part no. 0-ZS-4-0-ZS-4-D 0-ZS-35-0-ZS-35-C 0-ZS-35-B 0-ZS-35-F 0-ZS-35-E How to Order Rated range to MPa 80H 0. to MPa ISE 0 N ZSE 80 0 N Nil Piping direction Piping specification F (G /4) is not available. Input/Output NPN open collector output PNP open collector output NPN open collector outputs PNP open collector outputs NPN open collector outputs nalog voltage output/uto-shift switching PNP open collector outputs nalog voltage output/uto-shift switching NPN open collector outputs nalog current output/uto-shift switching PNP open collector outputs nalog current output/uto-shift switching Table Made to Order Caution This product is the 0-ZSE80/ISE80 series blown with air and double packed in a Class M3.5 (ISO Class 5) clean room. L Nil B C D Option Nil M P M M None With bracket With bracket Note) Panel mount 0-ZS-35-C 0-ZS-4- Panel mount Front protection cover 0-ZS-35-F Note) only With unit switching function Note ) Fixed SI unit Note ) Initial value psi Made to Order Refer to Table below. Option 3 Symbol Nil Y K T Operating Note) manual (Booklet) (Booklet) Calibration certificate Note ) Under the New Measurement Law, sales of switches with the unit switching function are not allowed for use in Japan. Note ) Fixed unit 0-ISE80H : MPa Others : MPa, kpa Option 0-ZS-35-0-ZS-4-D Note) ll texts in both English and Japanese 0-ZS-35-B 0-ZS-35-E 340 Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors

2 Specifications Refer to the SMC website for Pressure Switches Precautions (M-E03-3) and Specific Product Precautions (Operation Manual). Model Rated range Display/Set range Withstand Wetted parts material Display/Smallest settable increment pplicable fluid Power supply voltage Current consumption Switch output Repeatability Hysteresis nalog output uto-shift input Display Display accuracy Indicator light Environment resistance Temperature characteristics Lead wire Maximum load current Maximum load voltage Residual voltage Response time Short circuit protection Standards Cleanliness class (ISO class) Hysteresis mode Window comparator mode Output voltage Voltage (Rated range) output Linearity Output impedance Output current (Rated range) Current Linearity output impedance Enclosure Operating temperature range Operating humidity range Withstand voltage Insulation resistance 0-ZSE80 (Vacuum ) 0-ISE80 (Positive ) 0.00 to.000 MPa 0.05 to.00 MPa MPa 0.0 to 0.0 kpa 00.0 to 00.0 kpa 0.00 to.00 MPa 0.0 to. kpa 0.0 to 0.0 kpa 0.05 to. MPa 500 kpa 4 MPa Pressure sensor: Stainless steel 630, Fitting: Stainless steel MPa (to.999) 0. kpa 0. kpa 0.00 MPa 0.0 MPa (.00 to) Fluids do not corrode stainless steel 630 and 304 to ±0%, Ripple (p-p) 0% or less (with power supply polarity protection) 45 m or less NPN output, NPN outputs, PNP output, PNP outputs 80 m 8 V (at NPN output) V or less (with load current of 80 m).5 ms (with anti-chattering function:, 00, 500, 000, 00 ms) Yes ±0.% F.S. ± digit to 5 V ±.5% F.S. 0-ZSE80F (Compound ) Variable (0 or above) ±% F.S. or less pprox. kω.4 to m 3. to m 4 to m ±.5% F.S. ±.5% F.S. ±.5% F.S. ±% F.S. or less Maximum load impedance: 300 Ω (Power supply voltage V) 600 Ω (Power supply voltage 4 V) Minimum load impedance: 50 Ω Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input 3 /-digit, 7-segment, -color LCD (Red/Green) ±% F.S. ± digit (mbient temperature of 5 ±3 C) Lights up when output is turned ON. OUT, OUT: Orange IP65 Operating: 0 to 50 C, Stored: 0 to 60 C (No freezing or condensation) Operating/Stored: 35 to 85% RH (No condensation) 50 VC for minute between live parts and case MΩ or more between live parts and case (at 50 VDC Mega) ±3% F.S. (Based on 5 C, within operating temperature range) Oilproof heavy-duty vinyl cable, 3 cores (N.P) 4 cores (.B) 5 cores (R.T.S.V) CE UL/CS (E6656) RoHS Class 4 0-ISE80H (Positive ) 0.6 to 5 V ±.5% F.S. 0.8 to 5 V ±.5% F.S. ø3.5, m Conductor area: 0.5 mm (WG6) Insulator O.D.: 0.95 mm Piping Specifications Model Port size Weight () Weight () Leakage 0 R/4 7 g 89 g N0 NPT/4 F0 G/4 C0 Rc/8 URJ/4 B TSJ/4 8 g 4 g g g 90 g 86 g 86 g 9 g 83 g x 0 5 Pa m 3 /s x 0 0 Pa m 3 /s 34

3 Set Pressure Range and Rated Pressure Range Set the within the rated range. The set range is the range of that is possible in setting. The rated range is the range of that satisfies the specifications (accuracy, linearity, etc.) on the switch. lthough it is possible to set a value outside the rated range, the specifications will not be guaranteed even if the value stays within the set range. Directional Control Valves For vacuum For compound For positive nalog Output Voltage output nalog output [V] 5 Switch 0.6 B 0-ZSE80 0-ZSE80F 0-ISE80 0-ISE80H C 0 kpa kpa 0 kpa 00 kpa 0. MPa Pressure Pressure range 00 kpa 0 00 kpa MPa MPa Current output nalog output [m] 4.4 B 0 0 kpa C Range For vacuum For compound For positive Pressure 00 kpa 0 kpa Rated range 0.0 to 0.0 kpa MPa 0.05 MPa. MPa 0. MPa 0.05 MPa 0. kpa B 0 C 0.0 kpa 00.0 to 00.0 kpa 00.0 kpa 00.0 kpa 0.00 to.000 MPa 0.00 MPa MPa 0.00 to.00 MPa 0.00 MPa Note) 0.00 MPa Note) nalog output is 0.8 [V] or 3. [m] at the. MPa. MPa Rated range of switch Set range of switch ir Preparation Flow Control Pressure Control Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders 34 Pressure Switches/ Pressure Sensors

4 U U Internal Circuit and Wiring Example -N NPN ( outputs) -P PNP ( outputs) Main circuit Black OUT to Main circuit Black OUT to Blue DC () Blue DC () Max. 8 V, 80 m Residual voltage V or less Max. 80 m Residual voltage V or less - NPN ( outputs) -B PNP ( outputs) Main circuit Main circuit Max. 8 V, 80 m Residual voltage V or less Main circuit Black OUT White OUT Blue DC () -R, -S R: NPN ( outputs) nalog voltage output S: NPN ( outputs) nalog current output Max. 8 V, 80 m Residual voltage V or less Gray nalog output Black OUT White OUT Blue DC () -T, -V T: PNP ( outputs) nalog voltage output V: PNP ( outputs) nalog current output Gray nalog output Black OUT White OUT to to to Main circuit Max. 80 m Residual voltage V or less Main circuit Main circuit Black OUT White OUT Blue DC () -R/-S NPN ( outputs) uto-shift input Max. 8 V, 80 m Residual voltage V or less Gray uto-shift input Black OUT White OUT Blue DC () -T/-V PNP ( outputs) uto-shift input Gray uto-shift input Black OUT White OUT to to to Blue DC () Blue DC () Max. 80 m Residual voltage V or less 343 Max. 80 m Residual voltage V or less

5 Dimensions (For details about lead wires, refer to the product specifications.) 0-ZSE80/0-ISE80-0 N0 F0 C0 B (N0: 50.) 8.5 M5 x 0.8 thread depth 5 Directional Control Valves tmospheric vent port ø.6 6. ø Rc/8 -C0: Rc/ : R/4 N0: NPT/4 x M3 x 0.5 thread depth 4 When the switch is used in a place where water and dust splashes may occur, insert a tube into the atmospheric vent port, and route the other end of the tube to a safe place away from water and dust. SMC TU045 (polyurethane, O.D. ø4, I.D. ø.5) suits to the switch. Note) If it is predicted that the, such as the water hammer or surge fluctuates rapidly, refer to the Handling Precautions stated in the Operation Manual at SMC website ( G/4 -F0: G/4.7 7 M5 x 0.8 thread depth 5 Width across flats 7 Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control URJ/4 TSJ/4 Flow Control -: URJ/4 -B: TSJ/4 344 Pressure Switches/ Pressure Sensors

6 Dimensions (For details about lead wires, refer to the product specifications.) 0-ZSE80/0-ISE80-0L N0L C0L L BL (N0L: 6.5) x M3 x 0.5 thread depth 4 ø3.5 0L: R/4 N0L: NPT/4 8.8 tmospheric vent port ø M5 x 0.8 thread depth 5 Width across flats When the switch is used in a place where water and dust splashes may occur, insert a tube into the atmospheric vent port, and route the other end of the tube to a safe place away from water and dust. SMC TU045 (polyurethane, O.D. ø4, I.D. ø.5) suits to the switch. Note) If it is predicted that the, such as the water hammer or surge fluctuates rapidly, refer to the Handling Precautions stated in the Operation Manual at SMC website ( Rc/8 URJ/4 TSJ/4 -C0L: Rc/8 -L: URJ/4 -BL: TSJ/4 345

7 Dimensions (For details about lead wires, refer to the product specifications.) With bracket () 0-ZS-4-30 Directional Control Valves ø View With bracket () 0-ZS-4-D.6 30 With bracket () x ø Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control ø3.5 Flow Control Pressure Switches/ Pressure Sensors

8 Dimensions (For details about lead wires, refer to the product specifications.) Panel mount () ± x n pcs. 4 x (n pcs. ) 36± Panel thickness to 5 mm 38.6 Panel-cut dimensions 4 x R3 or less 67 or more 4 x R3 or less 347

9 Dimensions (For details about lead wires, refer to the product specifications.) Panel mount () Directional Control Valves 5. Panel-cut dimensions 36± ±0.3 Panel thickness to 5 mm x n pcs. 4 x (n pcs. ) 4 x R3 or less 4 x R3 or less Flow Control 7. ir Preparation Pressure Control Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders 348 Pressure Switches/ Pressure Sensors

10 Function Details uto-shift function (F4) When there are large fluctuations in the supply, the switch may fail to operate correctly. The auto-shift function compensates such supply fluctuations. It measures the at the time of auto-shift signal input and uses it as the reference to correct the set-value on the switch. Set-value correction by auto-shift function (Differential) Pressure Switch output () uto-shift input P- (P-3) H- (H-) ON OFF Hi Lo Supply normal Supply drop Rectified value Supply increase B Switch output 5 ms or more 0 ms or less response time when autoshift is input. Rectified value When the auto-shift is selected, ooo will be displayed for approximately second, and the value at that point will be saved as a rectified value C_5. Based on the saved rectified values, the set-value Note) of P_, H_, P_, and H_ will likewise be rectified. Note) When an output is reversed, n_, H_, n_, H_ will be rectified. Possible Set Range for uto-shift Input Regulating range Compound 0.0 to 0.0 kpa Vacuum 0.0 to.0 kpa 0.05 to.00 MPa Positive 0.05 to. MPa Rectified value Possible set range to kpa.0 to.0 kpa.5 to.5 MPa.3 to.3 MPa uto-shift zero The basic function of auto-shift zero is the same as the function for auto-shift. lso, it corrects values on the display, based on a value of 0, when the auto-shift is selected. B uto-preset function (F8) uto-preset function, when selected in the initial setting, calculates and stores the set-value from the measured. The optimum set-value is determined automatically by repeating vacuum and break with the target workpiece several times. Suction Verification C Precision indicator setting function (F7) Fine adjustment of the indicated value can be made within the range of ±5% of the read value. The scattering of the indicated value can be eliminated. Display value F in brackets stand for the function codes. Refer to the operating manual for how to operate and function codes in detail. High Vacuum Max. P- H- n- Min. B tmosphere ±5% R.D. Suction Work Work Released Work Work Work n Formula for Obtaining the Set-Value P_ or P_ P_ (P_) = (-B)/4 n_ (n_) = B (-B)/4 0 pplied H_ or H_ Work n H_ (H_) = (-B)/ Displayed value at the time of shipment djustable range of display calibration function Note) When the precision indicator setting function is used, the set value may change ± digit. D Peak and bottom display function This function constantly detects and updates the maximum (minimum) value and allows to hold the maximum (minimum) value. When the buttons are simultaneously pressed for second or longer, while holding, the hold value will be reset. E Key lock function This function prevents incorrect operations such as accidentally changing the set-value. F Zero-out function This function clears and resets the zero value on the display of measured. For the switch with analog output, the analog output shifts according to the indication. displayed value can be adjusted within ±0% F.S. of the when ex-factory. 349

11 Function Details G Error indication function Error name Overcurrent error Residual error pplied error uto-shift error System error Error code H nti-chattering function (F3) large bore cylinder or ejector consumes a large volume of air in operation and may experience a temporary drop in the supply. This function prevents detection of such temporary drops in the supply as an error. <Principle> This function averages values measured during the response time set by the user and then compares the average value with the set point value to output the result on the switch. Pressure Pressure range P- H- Internal data error Internal data error Internal data error Description current of switch output (OUT) exceeds 80 m. current of switch output (OUT) exceeds 80 m. It is still applied with that is ±0% over the atmospheric and the upper limit of the rated range when it is cleared to zero. fter displaying the error code for second, the switch automatically returns to the measuring mode. Due to individual product differences, the setting range varies ± digits. Supply exceeds the maximum set. Supply is below the minimum set. The value measured at the time of auto-shift input is outside the set range. fter displaying the error code for one second, the switch returns to the measuring mode. vailable response time settings ms, 00 ms, 500 ms, 000 ms, 00 ms Momentary change I Display unit switching function (F0) Display units can be switched with this function. Pressure range pplicable sensor Set range kpa MPa kgf/cm bar psi inhg For compound 0-ZSE80F 0-ZSE80 0 to 0 kpa For vacuum 0 to kpa mmhg 0-ISE80H: Does not indicate the last digit when the is.000 MPa or higher. K Secret code setting (F0) For positive 0-ISE80 0. to. MPa ISE80H 0. to. MPa J Power-saving mode (F9) OUT The numerical value disappears and the OUT decimal points blink. Power-saving mode can be selected. It shifts to the power-saving mode without button operation for 30 seconds. It is set to the normal mode (Power-saving mode is OFF.) when ex-factory. (Decimal points and operation indicator light (only when the switch output is turned ON.) blink in the power-saving mode.) OUT OUT Input an arbitrary three-digit value. The set-value can be confirmed when the key is locked. It can be set whether code number input is required or not when key is locked. It is set to input no code number when ex-factory. Directional Control Valves Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Switch output operation in normal conditions ON OFF Switch output operation when ON anti-chattering function is on. OFF t (ms) t (ms) Time <veraging> <veraging> Time Time 350 Flow Control Pressure Switches/ Pressure Sensors

12 Series 0-ZSE80/0-ISE80 Made to Order Please contact SMC for detailed dimensions, specifications, and lead times. Lead wire length 3 m Symbol -X50 It has a lead wire extended to 3 meters. How to Order 0-ZSE80(F)/0-ISE80(H) Piping Output Option Refer to How to Order on page 340 for standard specifications. X50 35

Series 10-ZSE30A(F)/10-ISE30A

Series 10-ZSE30A(F)/10-ISE30A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H

More information

Electronic Vacuum Regulator. Standard Specifications. Model Voltage

Electronic Vacuum Regulator. Standard Specifications. Model Voltage Electronic Vacuum Regulator Series ITV9/9 Stepless control of vacuum in proportion to an electric signal Straight type Piping/Wiring Diagram (VDC, madc) Vacuum pump, Ejector ITV9 Right angle type Tank

More information

Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output

Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output Electronic Vacuum Regulator Series ITV29/29 How to Order [Option] RoHS ITV 29 2 S 5 Pressure range 9.3 to 8 kpa Power supply voltage 24 VDC to 5 VDC Note) Communication models are available only for 24

More information

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0. SERIES Ultra-compact Digital Panel Controller CA Convenient s packed in a small body! Ultra-compact Large display Flexible scaling Conforming to EMC Directive Ultra-compact size of W 48 H 24 D 65.5 mm

More information

GC83 Digital Indicators & GC93 Digital Meter Relay

GC83 Digital Indicators & GC93 Digital Meter Relay Cat.No. B- GC83 Digital Indicators & GC93 Digital Meter Relay OUTLINE Model GC83 has been designed exclusively for indication. Model GC93 is equipped with a comparator like a relay and is applied to a

More information

Correction Reissue. Product Discontinuation Notices

Correction Reissue. Product Discontinuation Notices PRODUCT NEWS Correction Reissue Product Discontinuation Notices January 6, 2014 Pressure Sensors No. 2011265E(2) Discontinuation Notice of Pressure Sensor (Stainless diaphragm) E8AA series (Special product),

More information

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style Plug Lead Unit Series 000 [Option] How to Order Manifold S 0 FD D Electrical entry F kit D-sub connector kit P kit Kit type Flat ribbon cable connector kit J kit Flat ribbon cable (0P) (PC Wiring System

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance 1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

0.01kV (0 to ±0.99 kv)

0.01kV (0 to ±0.99 kv) Handheld Electrostatic Meter Series IZH10 Easy-to-use handheld electrostatic meter Rated charge amount range: ±20.0 kv Minimum display unit: 0.1kV (±1.0 to ±20.0 kv) Check the current situation before

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance 13 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.139 Sensor selection guide... P.9~ General precautions... P.1 PHOTO PHOTO

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree of protection

More information

A new approach to static electricity countermeasures

A new approach to static electricity countermeasures Advanced intelligent Sensors NEW ELECTROSTATIC SENSOR EF-SSERIES A new approach to static electricity countermeasures Measurement of surface potentials while a production line is running Phone: 8.894.42

More information

Optimising controls Vacuum switches

Optimising controls Vacuum switches Vacuum switches, pneumatic Converts a vacuum level to a pneumatic signal. Vacuum-actuated membrane linked to a pneumatic switch. Available preset or with adjustable vacuum level. Unit Value Feed pressure,

More information

Solid State Pressure Sensors D8M

Solid State Pressure Sensors D8M Solid State Pressure Sensors D8M Solid State Pressure Sensors with Analog, Pulse or Frequency Outputs Compact housing measures 30L x 30W x 12.4H mm. Accept 4 mm OD tubing (D8M-A1, -R1); 3 mm OD tubing

More information

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ). ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,

More information

E2S World's Smallest Square Sensor with Built-in Amplifier

E2S World's Smallest Square Sensor with Built-in Amplifier Compact Square Inductive ES World's Smallest Square Sensor with uilt-in mplifier Features 5.5 mm World's Smallest Sensor with uilt-in mplifier The 5.5 mm x 5.5 mm type permits smaller, space-saving machines

More information

Multifunction Pulse-to-Pneumatic Converter

Multifunction Pulse-to-Pneumatic Converter No. SS2-APN100-0100 Multifunction Pulse-to-Pneumatic Converter Model J-APN11 OVERVIEW The Multifunction Pulse-to-Pneumatic Converter receives an up/down pulse signal to drive a 4-phase pulse motor and

More information

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

Dissolved Oxygen Transmitter (For Low-Concentration Measurement) OBM-165H

Dissolved Oxygen Transmitter (For Low-Concentration Measurement) OBM-165H Dissolved Oxygen Transmitter (For Low-Concentration Measurement) OM-65H The OM-65H is a -wire type (4VDC power supply) dissolved oxygen transmitter (for Low-Concentration Measurement) housed in a robust,

More information

Pressure Transmitter SIL

Pressure Transmitter SIL Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) Electronic pressure measurement OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 Applications Hydraulics and pneumatics Pumps and compressors

More information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing The Modus M Series family of differential pressure transmitters measure low pressures, and feature a variety of analog signal outputs with low power consumption. A wide selection of standard pressure ranges

More information

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Long-distance detection of up to 6,000 mm supports a wide variety of applications. The Sensor is not

More information

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting

More information

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer. 99 PHOTO PHOTO LED Beam Sensor - SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.~ CA... P.79 ~ General precautions... P.7 Conforming to EMC Directive

More information

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763) A Sensor Designed with the Customer Applications in Mind! High Accuracy The PS400 and PS500 provide an accuracy rating of ±0.5 percent of the full scale. Flexible Mounting Options Multiple threaded connections

More information

ThermoPLUS Smart Temperature Transmitter

ThermoPLUS Smart Temperature Transmitter No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature

More information

CZ-K Series. RGB Digital Fiberoptic Sensors. Description MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

CZ-K Series. RGB Digital Fiberoptic Sensors. Description MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE RGB Digital Fiberoptic Sensors CZ-K Series Features RGB three-light source Wide detection range of 70 ±20 mm 2.75" ±0.78" High-speed response of 300 µs Water-resistant sensor head IP-67 rated Detecting

More information

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors. / Length (2D CMOS Laser Type) Advanced Functions Integrated into a Compact Sensor for Easy Handling of High-grade Applications A Controller the size of a business card combined with the smallest Sensor

More information

PZ-30 PRESSURE INDICATORS P Z N V S T I FEATURES MODEL NUMBER DESIGNATION LIST OF MODEL NUMBERS

PZ-30 PRESSURE INDICATORS P Z N V S T I FEATURES MODEL NUMBER DESIGNATION LIST OF MODEL NUMBERS marking patible with EMC directive kinds of display multiplier Full 3-digit red Small 3 mm square face Except for Current output type patible with our analog sensors FETURES Pressure indicators separated

More information

PRESSURE SENSORS I INSTALATION AND OPERATION INSTRUCTIONS ACCUTRON MDP BIDIRECTIONAL DIFFERENTIAL PRESSURE SENSOR

PRESSURE SENSORS I INSTALATION AND OPERATION INSTRUCTIONS ACCUTRON MDP BIDIRECTIONAL DIFFERENTIAL PRESSURE SENSOR PRESSURE SENSORS I INSTALATION AND OPERATION INSTRUCTIONS ACCUTRON MDP BIDIRECTIONAL DIFFERENTIAL PRESSURE SENSOR ACC-MDP DIMENSIONS AND HARDWARE 2.10 " [5 3.40 mm ] 1.05 " [26.70 mm ] Ø0.19" [Ø4.76m m]

More information

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer. 99 PHOTO PHOTO LED Beam Sensor - SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.~ CA... P.79 ~ General precautions... P.7 Conforming to EMC Directive

More information

Cylindrical type proximity sensor

Cylindrical type proximity sensor Cylindrical type Cylindrical type proximity Features Improved the noise resistance with dedicated IC Built-in reverse polarity protection circuit (DC 3-wire type) Built-in surge protection circuit Built-in

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com distance Supply voltage

More information

Self-Powered Counters H7ET

Self-Powered Counters H7ET Self-Powered Counters Subminiature Time Totalizers Require No External Power Supply Subminiature 8 x 2 mm (1.89 x.9 in) Improved noise immunity Screw terminal and wire-wrap types available Printed circuit

More information

INSTRUCTION MANUAL SMART POSITIONER ESL & ESR SERIES. ESL & ESR Series. Installation & Maintenance Manual

INSTRUCTION MANUAL SMART POSITIONER ESL & ESR SERIES. ESL & ESR Series. Installation & Maintenance Manual INSTRUCTION MANUAL SMART POSITIONER ESL & ESR SERIES 1 September 26, 2005 - I N D E X - 1. Features.... P.3 11-6] Sub-Parameters... P.14 2. Specifications 11-6-1] Changing Input Signal. 3. Principle of

More information

Digital Fiber-Optic Switches

Digital Fiber-Optic Switches CP-PC-2259E Digital Fiber-Optic Switches Model HPX-EG0 0/01 : Standard Model HPX-EG/ 51 : Long-dis tance Sensing Satisfaction Freedom from Frequent Adjustments Please read Terms and Conditions from the

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Monitoring Relay MR 50

Monitoring Relay MR 50 Monitoring Relay MR 50 Standard signals 0/4... 20 m, 0/2... 10 V DC Features M Input standard signals 0/4... 20 m, 0/2... 10 V DC M Measuring range programmable M Basic accuracy 0.1 % +/- 1 Digit M Installed

More information

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description Description The Series T family of differential pressure transmitters measure low pressures and feature low power consumption and a variety of analog signal outputs. A wide selection of standard pressure

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

Ionizer. Potential amplitude: 25 V or less Rapid neutralization of static electricity: Fastest time: 0.1 seconds. Series IZS40/41/42.

Ionizer. Potential amplitude: 25 V or less Rapid neutralization of static electricity: Fastest time: 0.1 seconds. Series IZS40/41/42. Ionizer Note ) Potential amplitude: V or less Rapid neutralization of static electricity: Fastest time:. seconds Note ) RoHS Dual C type Series IZS Potential amplitude of the workpiece is reduced with

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

DP2500 DP0100 DP0250 Differential Pressure Transmitter

DP2500 DP0100 DP0250 Differential Pressure Transmitter PB_DPT_03 2010 DP2500 DP0100 DP0250 Differential Pressure Transmitter The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view R Subminiature Photoelectric Sensor Omron s Next Generation of Sub-miniature Photoelectric Sensors H Utilizes Omron s Hyper LED technology to achieve the industry s smallest visible red beam H Self-contained

More information

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU Level probe Features Assembly Device for hydrostatic pressure measurement in liquids High resistance to overload High-precision, robust ceramic measuring cell with longterm stability Simultaneous level

More information

Series LC8. Positioning Driver/For AC Servomotor. Compliant actuators/series LJ1, Series LG1, Series LTF

Series LC8. Positioning Driver/For AC Servomotor. Compliant actuators/series LJ1, Series LG1, Series LTF Positioning Driver/For AC Servomotor Series LC Compliant actuators/series LJ, Series LG, Series LTF Ho to Order Master LC B H N M F 50 W 0 W 00 W Poer voltage 0 VAC/5 VAC 00 VAC/ VAC Command I/O N NPN

More information

Beamex MC2 HAND-HELD CALIBRATOR. Practicality in calibration

Beamex MC2 HAND-HELD CALIBRATOR. Practicality in calibration Beamex MC2 HAND-HELD CALIBRATOR 51 Practicality in calibration 52 MC2 series: three different hand-held calibrators for field use Practicality in calibration. The Beamex MC2 series includes three different

More information

FAS 10 mm PICOSOL Direct acting solenoid valve

FAS 10 mm PICOSOL Direct acting solenoid valve FS 0 mm PICOSOL > > /, /; Manifold mounting > > Long life 00 million cycles > > Compact Design > > Low power consumption Technical features Medium: ir, oxygen, neutral gases (0 %... 9 % humidity, non condensing),

More information

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models Standard Flat Inductive Proximity Sensors Front and side facing surface IP67 DC -wire and DC -wire models Ordering Information DC -wire Models Shape distance Model Output and operating status mm MD1 *1

More information

High Accuracy Positioning Sensors EG Series Features

High Accuracy Positioning Sensors EG Series Features High ccuracy Positioning s EG Series Features Ultra-small sensor head Non-contact, stable detection in wide temperature range Highly stable amplifier provides 1 µm. Mil repeatability Hi/Lo tolerance detection

More information

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor 43 PHOTO PHOTO Ultra-slim Sensor NA-PK5 SERIES SERIES General terms and conditions... F-3 guide... P.49~ Related Information Glossary of terms... P.549~ General precautions... P.55~ Recognition Make sure

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view R Subminiature Photoelectric Sensor Omron s Next Generation of Sub-miniature Photoelectric Sensors H Utilizes Omron s Hyper LED technology to achieve the industry s smallest visible red beam H Self-contained

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Connection targets. Universal sensors and switches, universal output devices

Connection targets. Universal sensors and switches, universal output devices AnyWireASLK System Products Guide ASLKTERMAL [ASLK Small Terminal Block Terminal] BL296 B-08F EURO block type The Products Guide describes individual products. Refer to the Guide as necessary. Function

More information

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

High Reliability Of Fiber Optic Amplifier For Convenient Mounting Amplifier Reliability Of Amplifier For Convenient Mounting Features speed response: Max. 0.5ms Auto (Button setting)/remote synchronization input, mutual interference protection, selfdiagnosis Reverse

More information

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view) Built-in Amplifier Photoelectric Sensor E3S-A/B Revolutionary High-performance High-quality Sensor with Built-in Amplifier can be adjusted in seconds because the optical axis coincides with the mounting

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) Pressure OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 for further approvals see page 11 Applications Hydraulics and pneumatics Pumps and compressors

More information

High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology

High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology High-speed, High-Accuracy Digital Displacement Inductive Sensor EX-V Series High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology High-Performance

More information

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R WLL 0 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC 0... 0 mm Through-beam systems Dimensional drawing R. -R. Scanning distance 0... 0 mm. Proximity systems

More information

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that

More information

LX-100 SERIES Conforming to EMC Directive

LX-100 SERIES Conforming to EMC Directive PHOTOELECTRIC SENSOR DIGITAL MARK SENSOR LX-100 SERIES Conforming to EMC Directive Introducing the ultimate mark sensor High resolution A/D converter Automatic optimal LED selection function Lead-free

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC

More information

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES 9 0 mm Beam Pitch General Purpose Area Sensor SERIES Related Information General terms and conditions... F- Glossary of terms / General precautions...p.59~ / P.55~ guide... P.9~ Korea s S-mark... P.60

More information

USA series. Capable of long-distance measurement Built-in teaching function for simple operation and highlyaccurate

USA series. Capable of long-distance measurement Built-in teaching function for simple operation and highlyaccurate series Ultrasonic displacement sensors (3m Type) Capable of long-distance measurement Built-in teaching function for simple operation and highlyaccurate measurement Integrated temperature sensor for stable

More information

M/SSL/SSR/E INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES

M/SSL/SSR/E INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES M/SSL/SSR/E 01 2009 INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES 1 - I N D E X - 1. Features.... P.3 11-6] Sub-Parameters... 2. Specifications 11-6-1] Changing Input Signal. P.15 3. Principle

More information

High-quality pressure transmitter For general industrial applications Model S-20

High-quality pressure transmitter For general industrial applications Model S-20 Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-20 WIKA data sheet PE 81.61 Applications Critical industrial applications Demanding applications

More information

Base Mounted Plug-in Unit

Base Mounted Plug-in Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. 000 Plug-in Unit SI unit COM N V V C C C6 M CM 6 B B B6 B M 000 Manifold model Plug-in unit Stations

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers

More information

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English

More information

Grundfos Direct Sensor

Grundfos Direct Sensor GRUNDFOS DT OOKLET Grundfos Direct Sensor sensors Grundfos Direct Sensor Table of contents 1. Product introduction 3 Type key 4 2. Relative- sensor, Industry (RPI) 5 RPI / RPI +T general data 5 RPI, 0-0.6

More information

LX-100 SERIES. Digital Mark Sensor Amplifier Built-in. Introduction of the 3 LED mark sensor 4:1. Can detect any mark!

LX-100 SERIES. Digital Mark Sensor Amplifier Built-in. Introduction of the 3 LED mark sensor 4:1. Can detect any mark! 899 PHOTO PHOTO Digital Mark Sensor Amplifier Built-in SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.149~ guide...p.86~ General precautions... P.12~ Recognition

More information

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters Series T Differential Pressure Transmitters The Series T family of differential pressure transmitters measure low pressures and feature low power consumption and a variety of analog signal outputs. A wide

More information

Set model No. ESN-T8. 140mm ESN-T mm ESN-T mm ESN-T mm. Light axis interval: 20mm. Smallest detectable object diameter: 30 mm

Set model No. ESN-T8. 140mm ESN-T mm ESN-T mm ESN-T mm. Light axis interval: 20mm. Smallest detectable object diameter: 30 mm series Light urtain Sensors Ultra-thin Slim type of only mm thick and mm wide never affecting work efficiency High-intensity red LED employed Large operation indicator of high-intensity LEDs in series

More information

Adsorption Plate. SP Series. Specialized for adsorption and fixing in place of thin sheets, glass substrates, and soft workpieces.

Adsorption Plate. SP Series. Specialized for adsorption and fixing in place of thin sheets, glass substrates, and soft workpieces. dsorption Plate Series Specialized for adsorption and fixing in place of thin sheets, glass substrates, and soft workpieces. ZUK MJ J MV 749 Ideal for adsorption and fixing in place of thin sheets, glass

More information

Beamex MC5-IS INTRINSICALLY SAFE MULTIFUNCTION CALIBRATOR. Made for extreme environments

Beamex MC5-IS INTRINSICALLY SAFE MULTIFUNCTION CALIBRATOR. Made for extreme environments Beamex MC5-IS INTRINSICALLY SAFE MULTIFUNCTION CALIBRATOR 63 Made for extreme environments Made for extreme environments 64 MC5-IS: designed for use in potentially explosive environments The ATEX- and

More information

2 AMP. HIGH CAPACITY RELAY WITH HIGH SURGE VOLTAGE & HIGH BREAKDOWN VOLTAGE FEATURES. Characteristics. Initial breakdown voltage

2 AMP. HIGH CAPACITY RELAY WITH HIGH SURGE VOLTAGE & HIGH BREAKDOWN VOLTAGE FEATURES. Characteristics. Initial breakdown voltage TESTING 2 MP. HIGH PITY RELY WITH HIGH SURGE VOLTGE & HIGH REKDOWN VOLTGE TX-RELYS 8.4.33 FETURES reakdown voltage between contacts and coil: 2, V Surge withstand between contacts and coil: 2, V High contact

More information

HG-C SERIES. Micro Laser Distance Sensor. Reliable detection in 10 μm precision. We offer three types of laser sensor heads for various applications

HG-C SERIES. Micro Laser Distance Sensor. Reliable detection in 10 μm precision. We offer three types of laser sensor heads for various applications 215 PHOTO PHOTO LIGHT CURTAINS / USE Micro Laser Distance Sensor SERIES Related Information General terms and conditions... F-7 Glossary of terms / General precautions.. P.1455~ / P.1458~ Sensor selection

More information

Product Discontinuation Notices

Product Discontinuation Notices PRODUCT NEWS Product Discontinuation Notices August 1, 2011 Ultrasonic Sensors No. 2011264E Discontinuation Notice of Ultrasonic Sensor E4A special specification model, E4B special specification model,

More information

U5700 Submersible Liquid Level Pressure Transducer

U5700 Submersible Liquid Level Pressure Transducer High Accuracy CE Compliant Compact Variety of Pressure Port Configurations Waterproof Optional Stainless Steel Snubber IP68 Rated Connection and Submersible Polyurethane Jacketed Cable Gage, Sealed, Absolute,

More information

Simplified Operations for TM-3100 Series Digital Tachometer

Simplified Operations for TM-3100 Series Digital Tachometer Simplified Operations for TM-3100 Series Digital Tachometer The TM-3100 series Digital Tachometers has the most fundamental function in rotational measurement of four standard models (rotation speed display,

More information

Ultrasonic Displacement Sensor E4DA

Ultrasonic Displacement Sensor E4DA Sensing Supply voltage Output Ultrasonic beam Ultrasonic Displacement Sensor Sensor s Narrow Ultrasonic Beam Accurately Detects Small Objects, Provides Linear Analog Output For Inspection, Measurement

More information

+GF+ SIGNET Temperature Transmitter Instructions

+GF+ SIGNET Temperature Transmitter Instructions GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal

More information

Pressure transmitter AKS 32 and AKS 33

Pressure transmitter AKS 32 and AKS 33 Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS

More information

FAST SAMPLING CONVERTER

FAST SAMPLING CONVERTER FAST SAMPLING CONVERTER ML4-F1 HIGH SAMPLING RATE CONVERTER (UP TO 400 SAMPLES/SECOND) Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information