Monitoring Relay MR 50
|
|
- Francine Robertson
- 5 years ago
- Views:
Transcription
1 Monitoring Relay MR 50 Standard signals 0/ m, 0/ V DC Features M Input standard signals 0/ m, 0/ V DC M Measuring range programmable M Basic accuracy 0.1 % +/- 1 Digit M Installed units: mv, V, m,, Ω, kω, µs/cm, ms/cm, C, F, min -1, rpm, bar, mbar, hpa, mm, cm, m, %,, l, l/min, m³, m³/h, ppm custom units programmable M Simulator function M Fault monitoring for break of wire in the measuring circuit M Programmable fault function nalog output min. or max. overflow larm outputs min. or max. function M Integrated transmitter supply 24 V DC max. 30 m M 4 alarm outputs (relay SPDT) M Isolated analog output 0/ m; 0/ V DC M Full 3-port isolation General The Monitoring Relay has inputs for industry standard signals 0/ m and 0/ V DC. Measuring value and programmed unit are shown in the display. The integrated transmitter supply offers direct connection of loop powered sensors. Simple programming, up to 4 alarm outputs (SPDT) and optional available fully isolated free programmable analog output 0/ m; 0/ V DC meets the demand for different applications. Peak value indication for minimum and maximum measured values are stored in the background and can be read out from the display at any time. Short information Programming Inputs larm outputs Fault function The device is programmed by frontal buttons, in connection with the LCD display. Standard signal 0/ m and 0/ V DC The alarm outputs can be programmed as max. or min. function. Switch-on delay and switch-off delay time is programmable from 1 s up to 9 h. The switching status is displayed through LED s. break of wire in the measuring circuit could be monitored. The switching function of the analog and alarm output(s) is programmable in case of an fault
2 Technical data Power supply Supply voltage : 230 V C ±10 %, 115 V C ±10 %, or 24 V DC ±15 % Power consumption : < 5 V Operating temperature : C ( F) Rated voltage : 250 VC acc. to DIN EN between input/relay output/analog output/supply voltage degree of pollution 2, overvoltage category III Test voltage : 4 kv DC between input/relay output/analog output/supply voltage -conformity Standardize IEC /2004 IEC (ESD) IEC (E-field) IEC (Magnetic filed) IEC (Voltage dip) IEC (Burst) IEC (Surge) IEC (HF current feed) IEC (Burst) IEC (Surge) IEC (HF current feed) IEC (Burst) IEC (Surge) IEC (HF current feed) Case C power supply connection DC power supply connection Input/output, signal/control 4 kv/8 kv contact/air 10 V/m 30 /m 0.5 period, ±100% 2 kv 1 kv L/N, 2 kv L,N/PE 3 V 2 kv 1 kv L/N, 2 kv L,N/PE 3 V 1 kv 1 kv L/N/PE 3 V Result B dispensed with B CISPR16-1/16-2 Radiated interference Passed Input Fault detection Input resistance Basic accuracy Temperature coefficient Transmitter supply Output larm outputs 1-4 nalog output Fault function : 0/ m; 0/ V DC : Break of wire in the measuring circuit : Current input 10 Ω, voltage input 10 kω : <0.1 %, ±1 Digit : 0.01 %/K : 24 V DC max. 30 m : Relay SPDT < 250 V C < 250 V < 2 cosn 0,3, < 300 V DC < 40 W <2 : 0/ m burden 500 Ω; 0/ V burden >500 Ω, galv. isolated, output changes automatically (burden impedance dependent). : For break of wire detection nalog output 0 m, < 3.6 m or > 21.5 m programmable larm output(s) min. or max. function programmable : Graphic LCD- 128x64 pixels, white background illuminated Case : Polyamide (P) 6.6, UL94V-0, DIN rail mounting TS 35 Weight : approx. 450 g Connection : Screw terminals mm² (WG ) Protection : Case IP30, terminals IP20, German BGV 3-2 -
3 Connection diagram Supply voltage nalog output 0/ m, 0/ V DC larm outputs Transmitter supply 24 V DC max. 30 m Current Voltage 2-wire sensor Dimensions Terminals Terminals Terminals Terminals
4 Controls and indicators Device name Measured value Input signal larm output 1 larm output 2 larm output 3 larm output 4 Power-ON LED Parameter button Up/down buttons Description The operation of the device is implemented in 2 levels. The required parameter is called up with the button. The selection within a parameter and the setting-adjustment of a value is implemented with the buttons and. Button combinations (press buttons simultaneously): + 1 parameter back + Parameter is set to "0" or minimum value. fter the switching on the supply voltage, the device initializes itself. In the display the message indicating device type and software version is shown. fter the initialization, the device is running in the working level. The peak value storage is called up and the setpoints of the alarm outputs can be programmed. The configuration level is called up by activation of the button for 2 seconds. In this case, all parameters which determine the properties of the device are programmed. fter the last menu item, or if no button is pressed for longer than 2 minutes, a skip-back into the working level is implemented automatically and the current measured value is indicated in the display. The configuration level can be exited at any time by holding down button for 2 seconds. Error reports In case of occurring faults, the messages are shown on the display in plain text. This simplifies location of the error. See description page 11. Operational startup reference! The device is preset with an ex-works default setting. Therefore it must be adapted to each special application. See Page
5 Note on the representation Parameter appears only with corresponding configuration Parameter appears only with corresponding equipment version Working level Description 22.4 bar Input: 4-20 m 22.4 bar 1: : : : 60.0 Input: 4-20m ctual-value displays Change between the two representations for the actual value display with the buttons and. Only the current value can either be displayed, or in addition, the adjusted values for the switching points of the alarm outputs. This selection is stored and is also retained after a voltage breakdown. Peak value display MX 35.0 bar MIN 0.0 bar Reset with Peak value display for minimum and maximum measured value. Delete with the button or with every power cut-off. Setpoint Fault det. Input larm output 1 MIN Setpoint alarm output 1 (switching function MIN or MX) llocation of the fault detection in the measuring circuit (break of wire Setpoint MX 20.0 bar Setpoint alarm output 2 (switching function MIN or MX) Setting possible from Digit larm output 2 Note: Setpoints for alarm outputs have to be configured in the same way
6 Configuration level Description (represented values are default settings) 22.4 bar Working level Input: 4-20 m Press 2s 1 Language Input 1.1 deutsch english Select language User Language deutsch english Selection 2 Language Input 2.1 Input signal 0-20m 4-20m Input signal 0-20 m 4-20 m 0-10 V DC 2-10 V DC Selection 2.2 Digital filter OFF Digital filter OFF or in steps of 0.5 s in the range from s Selection Input signal 3 Input 3.1 Contrast 65% contrast Setting possible from % 3.2 Unit mv V Continue page 7 unit The selected unit will be displayed and used for programming the characteristic curve. Installed units: mv, V, m,, Ω, kω, S/cm, ms/cm, C, F, min -1, rpm, bar, mbar, hpa, kpa, mm, cm, m, %,,l, l/min, m, m/h, ppm and custom. custom = max. 5 characters are free programmable. Selection - 6 -
7 3.3 Custom unit Unit text B/h Custom unit Maximal 5 characters possible (see character set below). Only appears if custom is selected Scrolling through the characters is possible The selected character will be entered with button. fter that, the cursor jumps to the next position. Selection procedure as before. If 5 characters are entered or no more character wanted, the parameter custom unit will excited automatically. Characters: 8 B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z ä ö ü ß.?!, : _ % / \ + - * [ ] ( ) < = > " µ Ω Decimal place Number of decimal places 0; 0.0; 0.00; Selection 3.5 Start value 0 mv Start value for display Setting possible from Digit 3.6 End value 100 mv End value for Setting possible from Digit 3.7 Correction 0 mv Measured value correction Setting possible from Digit Continue page 8-7 -
8 4 Output 4.1 nalog output 0-20 m 4-20 m (2-10V) Selection of the analog output 0-20 m (0-10 V DC) or 4-20 m (2-10 V DC) Selection utomatic changeover to voltage signal in case of load impedance > 500 Ω. 4.2 Start value 0 mv Start value analog output Setting possible from Digit nalog output 4.3 End value nalog output 100 mv End value analog output Setting possible from Digit Note: If start value > end value the output works with a decreasing characterisitc. 4.4 Correct. analog output NO YES Correction analog output Selection NO YES Correct. analog output m Start value (2.000V) Correction start value analog output Setting possible in the range ±2 m or ±1 V Correct. analog output m End value (10.000V) Correction end value analog output Setting possible in the range ±2 m or ±1 V Continue page Fault action >21 m <3.6 m nalog output (>10.5V) 4.6 Continue page 9 Fault action of the analog output for break of wire in the measuring circuit. > 21m at analog output 0-20/4-20 m <3.6 m at analog output 4-20m (2-10 V) 0 m at analog output 0-20 m (0-10 V) Selection - 8 -
9 4.6 larm output 1 OFF Limit Function Function alarm output 1 OFF Limit Monitoring of the measuring value Fault det. Break of wire Selection OFF larm output 1 MIN MX Switching function Limit/Fault det. Switching function alarm output 1 MIN, MX Selection Fault det. Limit Setpoint MX larm output mv Setpoint alarm output 1 Setting possible from digit Switching hysteresis 1 mv Hysteresis alarm output 1 Setting possible from digit larm output Switch-on delay time 0:00:00 h : mm : ss larm output 1 Switch-on delay time alarm output 1 Setting possible from 0:00: :00:00 (h:mm:ss) Switch-off delay time 0:00:00 h : mm : ss larm output 1 Switch-off delay time alarm output 1 Setting possible from 0:00: :00:00 (h:mm:ss) Note: The parameter settings for have to be configured in the same way. 4.7 Simulation 25 mv Simulation Der works as actuator. The analog output changes in the programmed range. Setting possible This parameter will not be excited automatically after 120 seconds. Continue page
10 5 Output Lock 5.1 Parameter lock OFF CONFIG Parameter lock OFF : no parameters locked CONFIG : Configuration level locked LL : all parameters locked Selection 6 Lock Code 6.1 Factory settings 0000 Code for Factory settings 7 Code End 22.4 bar Return to the working level Input: 4-20 m
11 Error reports Caution! Parameter locked switched on Description The parameter can not be changed, because the parameter lock for the configuration level, or work and configuration level, is switched on. Caution! Undervoltage Supply voltage to low Caution! XX Parameter error Please check t the check-up of the parameter memory, XX errors are detectet. The incorrect parameter are resetted to the factoty settings. Please check and correct parameters if necessary. Caution! XX Parameter error Calibration necessary s before, but the factory settings are incorrect. The device must be checked at works. Change of decimals? Some parameters not representable! dapt parameters automatically? Yes No Change of decimal places While changing number of decimal places, some parameters can be converted, but however, not represented! Selection "No" : Change of the decimal places is not carried out. Selection "Yes" : Decimal places are changed automatically, where the affected parameters are set to the maximum possible value. subsequent verification of the accepted parameters is absolutely necessary. Fault input Input: 9999mV Break of wire in the measuring circuit. Text Input: 9999mV is flashing
12 Ordering code Input 1 Standard signals 0/ m; 0/ V DC Transmitter supply 24 DC V max. 30 m 2. larm outputs 2R 2 relay outputs 3. larm outputs 00 not installed 2R 2 relay outputs 4. nalog output 00 not installed O nalog output 1, 2 SPDT 3, 4 SPDT 0/ m; 0/ V DC 5. Supply voltage V C V C 5 24 V DC ± 10 % ± 10 % ± 15 % Hz Hz 6. Options 00 without option Works configuration according to customer specifications. 01/08-V
Progr. Universal-Transmitter PMT 50 Signal conditioning - linearization - output characteristic transformation
GHM-Messtechnik GmbH Location Martens Progr. Universal-Transmitter PMT 50 Signal conditioning - linearization - output characteristic transformation Features M Input for standard signals, resistance/poti
More informationAlarm-Display SD 9648
Alarm-Display SD 9648 0 Digital- or 1 Digital- and 8 Analog inputs Features M Activation with voltage free contacts, 0/4 V signals or 0/4... 0 ma for monitoring of analog measuring values M First- or last
More informationInsulation Guard IW 1000 Monitoring of ungrounded AC- and DC voltage systems up to 690V
Insulation Guard IW 0 Monitoring of ungrounded AC- and DC voltage systems up to 690V Features M Time optimized pulse measuring method M Safe monitoring at extreme conditions (frequency converter, phase
More informationAnalog signal converters CC-E I/I
2CC 281 001 F0b06 Features Loop-powered I/I isolator without external power supply for analog current signals of 0-20 ma and 4-20 ma Electrical isolation between input and output Very low internal voltage
More informationPassive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)
Passive Current Transducers for Sinusoidal Alternate Currents From 0... A/0...5 A (-SW) Passive current transducer without power supply Measuring range A and 5 A AC, reconnectable Available with threshold
More informationMODEL: 47LV. Digital Panel Meters 47 Series
Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display
More informationCONTA-ELECTRONICS. Converter Units
CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to
More informationRCMS460 and RCMS490 Series
4 T M RCMS460 and RCMS490 Series Digital Multi-Channel Ground Fault Monitor / Ground Fault Relay Grounded and High-Resistance Grounded AC/DC Systems Technical Bulletin NAE1042060 / 04.2013 BENDER Inc.
More informationMODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series
Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationXR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)
XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided
More informationR24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY
Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the
More informationConductivity-Converter
Conductivity-Converter compact version separate version Condutec-LF / e Technical Information Operating Instructions Hengesbach GmbH & Co. KG * Schimmelbuschstr. 17 * D-40699 Erkrath * Tel.: +49 (0) 21
More informationNote The module converts unipolar and bipolar input signals
PROGRAMMABLE ANALOG SIGNAL CONVERTER THREE WAY GALVANIC ISOLATOR - 19 input scales - 7 output scales - 1 SPDT alarm contact - input/output isolation 3kV - auxiliary supply output for loop powered sensors
More informationMCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable
MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable 1. Short description configurable inputs and outputs signal conversion/amplification 3-way-isolation zero/span adjustment 17.5 mm ME housing
More informationMCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description
Voltage transducer for AC voltages TERFACE Data sheet 006_en_0 PHOENIX CONTACT 00-0- Description The MCR voltage transducer measures AC voltages in several signal ranges from 0... ±4 V AC to 0... ±30 V
More informationVert-X 22E - 5V / PWM. Applications Wind vanes Valve control Level sensor Special purpose vehicles
Sensor principle MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearitiy (without misalignment) % of meas. range ±0.3 - Indep. linearitiy (with allowed misalignment @ 360 ) % of meas. range
More informationMonitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71
Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71 DPC71 PPC71 TRMS 3-phase over and under voltage, phase sequence, phase loss, asymmetry and tolerance monitoring relay Detect
More informationFlow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes
GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications
More informationVert-X 22E - 24V / 4-20mA. Applications Wind vanes Valve control Level sensor Special purpose vehicles
Sensor principle MH-C MH-C2 Electrical data Measuring range 0... 360 0... 360 Indep. linearitiy (without misalignment) % of meas. range ±0.3 ±0.3 Indep. linearitiy (with allowed misalignment @ 360 ) %
More informationRS Pro ENGLISH. Datasheet
Datasheet Article No: 136-5385 Digital AC Ammeter, 48x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5387 Digital AC Ammeter, 96x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5388 Digital
More informationMonitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01
Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 DPC01 PPC01 TRMS 3-phase over and under voltage, phase sequence, phase loss, asymmetry and tolerance monitoring relay Detect
More informationXR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)
XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationVert-X 22E - 5V / % Ub. Applications Wind vanes Valve control Level sensor Special purpose vehicles
Sensor principle MH-C MH-C2 Electrical data Measuring range 0... 360 0... 360 Indep. linearitiy (without misalignment) % of meas. range ±0.3 ±0.3 Indep. linearitiy (with allowed misalignment @ 360 ) %
More informationVert-X 27E - 24V / SPI. Applications Harvesting machine Fork lift Hydraulic pump
Sensor principle MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearitiy (without misalignment) % of meas. range ±0.3 - Indep. linearitiy (with allowed misalignment @ 360 ) % of meas. range
More informationJUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature
Data Sheet 20272 Page /7 JUMO ecotrans Lf 0 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature Type 20272 Housing for DIN rail mounting (5 x 7.5 mm to DIN EN
More informationAnalog signal converters CC range
Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationTechnical data. General specifications. Measurement range min max. 360
Model Number Features Very small housing High climatic resistance 12 Bit singleturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationAnalog outputs (option) Output 1 + 2: 0(4) 20 ma or 0 10 V
Page / JUMO AQUIS 500 CR Transmitter/Controller for conductivity, TDS, resistivity and temperature Compliant with USP Brief description The instrument is used for the conductive measurement/control
More informationDSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters
Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and
More informationVert-X 27E - 24V / 4-20mA. Applications Harvesting machine Fork lift Hydraulic pump
Sensor principle MH-C MH-C2 Electrical data Measuring range 0... 360 0... 360 Indep. linearitiy (without misalignment) % of meas. range ±0.3 ±0.3 Indep. linearitiy (with allowed misalignment @ 360 ) %
More informationXUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)
XUA1 AC Voltage and phase balance relay (August 1996) Manual XUA1 (Revision New) Woodward Manual XUA1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
More informationAdjustable Digital Process Instrument MDK480
Description The adjustable Digital Process Instrument MDK480 is designed to measure and display process variables in industrial applications.the instrument is panel mounted with front frame dimensions
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationQUINT-PS-24DC/24DC/10
QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage
More informationVert-X 28HD - 24V / V. Applications Harvester Public transport Construction machines
Sensor principle MH-C MH-C2 Electrical data Measuring range 0...360 - Indep. linearity % of meas. range ±0.3 - Max. hysteresis 0.1 - Resolution bit 12 - Max. repeatability 0.1 - Sample rate fast mode khz
More information05/09/2012
17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option
More information5 years! Modular Housings. VariTrans P Warranty
Modular Housings VariTrans P 27000 The Multimeter among the isolators. With 480 switchable calibrated ranges and broad-range power supply. The Task A wide range of measuring signals need to be galvanically
More informationOperating instructions Electronic level sensor LK / / 2008
Operating instructions Electronic level sensor LK31 UK 704046 / 00 01 / 2008 Contents Safety instructions...2 Menu structure...3 Controls and indicating elements...4 Function and features...5 Functional
More informationMCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display.
Introduction & Selection Guide INTRODUCTION The Brodersen monitoring relays are high quality products incorporating up-to-date circuit design together with modern, efficient components to ensure a long
More informationXU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)
XU2-AC AC voltage relay (Februar 1997) Manual XU2-AC (Revision New) Woodward Manual XU2-AC GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
More informationXUA1 - AC Voltage and phase balance relay
XUA1 - AC Voltage and phase balance relay Contents 1. Applications and features 2. Design 3. Function 3.1 Voltage supervision 3.2 Unbalanced voltage supervision 4. Operation and settings 4.1 Setting of
More informationWeighing Instruments
GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation
More informationFixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
More informationVert-X 27E - 5V / % Ub. Applications Harvesting machine Fork lift Hydraulic pump
Sensor principle MH-C MH-C2 Electrical data Measuring range 0... 360 0... 360 Indep. linearitiy (without misalignment) % of meas. range ±0.3 ±0.3 Indep. linearitiy (with allowed misalignment @ 360 ) %
More informationCX105 Conductivity/Resistivity Transmitter
CX105 Conductivity/Resistivity Transmitter User Manual REV A.15 Sensorex Corporation, USA 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. www.sensorex.com IMPORTANT SAFETY INFORMATION Please read and
More informationAssembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail
Current/Voltage Trip Value Features Assembly 1-channel signal conditioner 24 V DC supply (Power Rail) Current and voltage input 2 relay outputs Programmable high/low alarm Configurable via DIP switches
More informationMonitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01
Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01 Product Description 3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry, over and
More informationAssembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail
Current/Voltage Trip Value Features Assembly 1-channel signal conditioner 24 V DC supply (Power Rail) Current and voltage input 2 relay outputs Programmable high/low alarm Configurable via DIP switches
More informationecotrans Lf 01/02 Transmitter / Switching Device for Conductivity Type B Operating Instructions 02.07/
ecotrans Lf 01/02 Transmitter / Switching Device for Conductivity Type 202731 B 20.2731.0 Operating Instructions 02.07/00435548 1 Notes 4 2 Identifying the device version 5 2.1 Type designation 5 3 Mounting
More informationPlease completely read through operating instructions! Do not discard! The warranty shall be invalidated by damage caused by operating errors!
Operating Instructions DULCOMETER D1C Part 2: Adjustment and Operation, Measured Variable Conductivity ProMinent D1C2-Leit.-001-GB Conductivity 100 µs/cm DULCOMETER STOP START Please completely read through
More informationConductivity Analyzer
Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationSwitching power supplies CP range, Linear power supplies CP-L range. Content
CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional
More informationThree-phase monitoring relays
2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted
More informationFixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
More informationisolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems
T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor
More informationWeighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier
GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier
More informationGrid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21
Data sheet Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21 The CM-UFD.M21 is a multifunctional grid feeding monitoring relay for three-phase mains. It provides different monitoring functions
More informationConductivity Transmitter N-LF V AC
OPERATING INSTRUCTIONS Conductivity Transmitter N-LF2000 230V AC These operating instructions apply to the following device: Article Measuring range Order number N-LF2000, Conductivity measuring device
More informationQUINT-PS/ 3AC/24DC/10
Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system
More informationType Nominal voltage (V) Code HSV V
Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works
More informationTechnical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity
KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator
More informationAC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/020
Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/020 0277078 RN 5897/020 RP 5898 Product Description The insulation monitor RN 5897/020 of the VARIMETER IMD family provides best and up to
More informationVert-X 16. Applications Servodrives Dancer arm Operating table
Version B C Electrical Data Measuring range 0... 360 360 Independent linearity see table B see table C Max. hysteresis see table B see table C Resolution see table B see table C Max. repeatability see
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
More informationElectronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet
2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection
More informationElectronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet
1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationMonitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01
Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types, TRMS 3-phase over and under voltage, phase sequence and phase loss monitoring relays Detect when all 3 phases are present and have the
More informationOperating Instruction
Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function
More informationPART NUMBERING SYSTEM
Plug-In Timer 11 pins Multifunction or monofunction Compact body for space saving Wide time range (from 0.5 seconds to 10 days delay) Universal power supply (12-240 Vz) 1 or 2 relay outputs (SPDT / Changeover)
More informationCurrent monitor Type C 551
Current monitor Type C 551 Relay for current monitoring, single-phase Monitoring AC and DC for overcurrent or undercurrent 1 yellow LED for indication of the relay state 1 green LED for indication of the
More informationMHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data
Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical
More informationALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationMINI MCR-SL-UI-f(-SP)
Configurable Analog Frequency Transducer INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The configurable analog frequency transducer MINI MCR-SL-UI-f(-SP) is used to convert analog standard
More informationMID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN
Energy Management Energy Analyzer Type EM11 DIN Other versions available (not certified, option X): see how to order on the next page Product Description Class 1 (kwh) according to EN62053-21 Class B (kwh)
More informationPART NUMBERING SYSTEM
Plug-In Timer pins Multifunction or monofunction Compact body for space saving Wide time range (from 0. seconds to 0 days delay) niversal power supply (-0 Vz) or relay outputs (SPDT / Changeover) Protective
More informationElectronic timers CT-S range Selection and ordering details
CT-S range Selection and ordering details Characteristics CT-S range CT-MFS 1SVR 430 010 F 0200 3 multifunction and 21 multi-range Continuous supply voltage range (24-240VAC/DC) or multisupply voltage
More information"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting
Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input
More informationTrip amplifier, 1 channel
Trip amplifier, channel Features I II III + + P I out I U out 4 Relay overrange Relay overrange Relay overrange ç 4...0 ma IM4-4-SRi: è 0...0 ma IV + + + > 50 kw 5 6 7 8 9»8 V < 5 ma 50 W Pwr GN/RD 4 5
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationElectronic measuring and monitoring relays CM-range
Electronic measuring and CM-range Content Benefits and advantages CM range, function overview... 30 Selection and ordering details Current and voltage monitors, single phase... 33 Three phase monitors...
More informationRS Pro ENGLISH. Datasheet
Datasheet ENGLISH Article No: 136-5390 Digital AC Ammeter, 48x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5391 Digital AC Ammeter, 96x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5393
More informationSINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator
SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically
More informationVert-X 37E - 5V / % Ub. Applications Agricultural machines Construction machines Forest machines Special purpose vehicles
Sensor principle Electrical data Measuring range 0... 360 0... 360 Indep. linearitiy (without misalignment) % of meas. range ±0.3 ±0.3 Indep. linearitiy (with allowed misalignment @ 360 ) % of meas. range
More informationQUINT-PS AC/24DC/40
Power supply unit INTERFACE Data sheet 102315_en_02 1 Description PHOENIX CONTACT 2010-04-23 Features QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high
More informationTemperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationMINI-PS AC/24DC/1.3
Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics
More informationHYBRID RECORDER OUTLINE
Specifications Sheet No.SPEC-33E (st Edition) RM0C HYRID RECORDER OUTLINE RM0C is 00mm calibrated hybrid recorder in a 44x44 DIN front panel and short depth of 50mm case housing. The recorder has versatility
More informationDigital Frequency Analog Transducer DFA 8.00 G DFA 8.00 T FEATURES Input 2
FEATURES Input: 2wire initiator (Namur) or potential free contact optional: second input for addition/ subtraction Output: Current (0)4 20 ma and/ or Voltage 0(2) 10 V optional: Switching outputs with
More informationVert-X 31E - 24V / SPI. Applications Concrete pump Access control system Fork lift
Sensor principle MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearity (typ.) % of meas. range ±0.3 - Max. hysteresis 0.1 - Resolution bit 14 - Max. repeatability 0.1 - Sample rate fast
More informationSINEAX TI 807 Passive DC signal isolator
without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate
More informationXI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)
XI1-I Time overcurrent relay (Januar 2007) Manual XI1-I (Revision New) Woodward Manual XI1-I GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
More informationGeneral Specifications
General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent
More information02/11/2015
35 mm - 2 Relays 8A PL2R1 Part number 88867455 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.
2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage
More informationTechnical Information Barrier RB223
TI00132R/09/EN/13.14 71275790 Products Solutions Services Technical Information Barrier RB223 One or two-channel barrier Loop-powered barrier for the safe separation of 4 to 20 ma standard signal circuits
More information