Isolated Intrinsic Safety Barrier

Size: px
Start display at page:

Download "Isolated Intrinsic Safety Barrier"

Transcription

1 Isolated Intrinsic Safety Barrier NPEXA Tosilon Automation NewPwR ThermocoupleCurrent input type Thermocouple Resistance Current input type MVMill Volt input type ResistanceResistance input type Current, wire input type Current output type Switch active, switch passive input type Switch active, switch passive output type Proximity switch input type RS48\\4 communication signal input type Frequency signal input type Eddy current, magnetic, magnetoresistive input type High impedance K Dual Your Professional Supplier for HazardousArea Application

2 About Tosilon NewPwR The factory located in Nanjing Luhe Economic and Technology Development Zone, covering an area of 0 acres, with more than 0 employees including about 0 R&D technical engineers, committee members of national standard committee. The company introduces advanced product line and advanced equipment from USA, Germany, England, etc. and has built a complete production management and quality control system. Up till now, we gets Ex certification, ATEX certification, CE certification from EU, FCC certification from USA, CCS shipment certification from China, and complied with SIL functional safety certification. Tosilon is tier one supplier of Sinopec, CNOOC, and designated supplier of China National Chemical Corporation. Meanwhile, we provide longterm supply for our country's major equipment such as military, aerospace and so on. We have formed a huge sales network all over the country. The total sales in 0 have exceeded 0,000 units and we have become one of the largest scale companies in the field of industrial instrument in China.

3 Qualification & Certificates ATEX

4 Qualification & Certificates FCC

5 Qualification & Certificates CE

6 Products Overview Series Code C C CM CM4 C C C7 C87 C89 C88 Description Thermocouple Signal Input / Output Type RTD Signal Input / Output Type Current Signal Input / Output Type Voltage Signal Input / Output Type Switch Signal Input / Output Type Frequency Signal Input / Output Type Communication Signal Input / Output Type Eddy Current Signal Input / Output Type Magnetic Resistance Signal Input / Output Type Magnetoelectronic Signal Input / Output Type Outline Structure for Reference 7.8mm.8mm 00mm mm Installation for Reference

7 Products Overview Thermocouple Signal Input / Output Type Referenced Model NPEXAC NPEXAC NPEXACA This type of isolated safety barrier transmits thermocouple signals from hazardous area to safe area by isolating transmitting current or voltage signals in a circuit or two isolated circuits, the input, output, and power supply are galvanically isolated from each other. Besides, it may also be connected in a connection network in safe area via communication ports. It is an intelligent product with online selfdiagnosis function. Customer may set the type and the range of the input or output signals with a handheld programmer we provide. Main Technical Parameters Explosiveproof grade: [Ex ia]iic Permissible input signal from hazardous area: Thermocouple:K, E, S, B, J, T, R, N Signal type and range can be specified at your order and may also be programmed by user. Output signal to safe area: DC current:0~0 ma, 4~0 ma, 0~0 ma DC voltage:0~ V, ~ V, 0~0 V Signal type and range can be specified at your order and may also be programmed by user. Transmitting accuracy (at o C± o C, without temperature compensation): Influence of ambient temperature: < 0 ppm/ o C Rise time: s (bounce from 0%~90%) Output load capacity: DC current: 0~0mA: 0~700 Ω; 4~0mA: 0~0Ω DC voltage: 0() ~ V: MΩ; 0~0V: MΩ Cold junction compensation range:0 o C ~0 o C Cold junction compensation accuracy: ± o C (Preheated for 0 minutes). Parameters certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST): TC type Measurable range Accuracy K/E/J/N etc. < 00 o C ±0. o C 00 o C ±0.% F S S/B/T/R/WReseries < 00 o C ±0. o C 00 o C ±0.% F S Um =0VAC/DC Between terminal &, 4 & : Uo=. V, Io=9.7 ma, Po=.8 mw IIC: Co=7. μf, Lo=4 mh IIB: Co=99 μf, Lo=79 mh IIA: Co=700 μf, Lo=000 mh

8 Products Overview Thermocouple Signal Input / Output Type Dielectric strength: 00V AC (Input/Output/, ma leakage current, minute test time) Insulation coordination: 00MΩ (Input/Output/) Electromagnetic compatibility: IEC 0004 : 8~V DC (Recommended voltage:4v DC) Power consumption: 0.W (4V power supply, 0mA single output) 0.7W (4V power supply, 0mA double output) Panel Light Indication: Light indicating: (green) remains illuminated during normal operation; Light indicating: (red)glitters or remains illuminated when signal fault occurs. Model Selection Code Lists: Model Note NPEXAC x x x x Thermocouple input isolated safety barrier Input loop st output nd output Communication / Alarm function (not coexists with nd output) D Single loop as default Double loop 4~0mA ~V 0~0mA 4 0~V 0~0V 0~0mA None as default 4~0mA ~V 0~0mA 4 0~V 0~0V 0~0mA None as default T T A A 48 communication (single output only) communication (single output only) Single relay alarm output Double relay alarm output Note: Thermocouple input type and the corresponding output range need to be specified when placing order. If you needs to program by yourself, please operate with computer or a handheld programmer.

9 Products Overview Thermocouple Signal Input / Output Type Wiring Diagram Dimension W H D (.8 00 )mm W H D ( )mm 7.8mm.8mm 00mm Output Input Tc 7 8 Output 9 mm 0 Input Tc Input Tc Input Tc 4 Input Tc Instructions R D A B Output Output 4 Relay output Relay output 4~0mA output 4V 4V Output Output Ambient Conditions Operating temperature range: 0~0 o C Relative humidity: 0%~90%RH Operating atmosphere pressure: 80~0kPa Storage and delivery temperature: 40~80 o C Installation Method Standard mm DIN rail installation, attention that position shall be stable and firm. In order to facilitate the heat of the instrument, Please mounted it vertically if possible. Calibration The product is of intelligent digital design and accuracy can be maintained within the range specified in this manual. If calibration is required, it shall be realized by the handheld programmer we provide. Operation Conditions Installation position shall not be affected by strong mechanical vibration, impact and electromagnetic induction from signal terminal and power supply, should conformity with the requirements on electromagnetic interference resistance of products in Class industrial field atmosphere stipulated in IEC 0004, and the atmosphere shall be free from gases that are corrosive to metal and plastic components. Supplementary Information If there is any content difference between the specification and the website or sample, this specification shall prevail. We reserve the rights to change or update the product information without prior noticing the users. For the thermocouple input barrier, the compensation wire should be connected directly to the input terminals on the barrier without other materials wire. Otherwise it will cause measurement errors.

10 Products Overview RTD Signal Input / Output Type Referenced Model NPEXAC NPEXAC NPEXACA This type of isolated safety barrier transmits RTD resistance signals from hazardous area to safe area by isolating transmitting current or voltage or resistance signals in a circuit or two isolated circuits, and it may also be connected in a connection network in safe area via communication ports. The input, output, and the power supply are galvanically isolated from each other. It is an intelligent product with online selfdiagnosis function. Customer may set the type and the range of the input or the output signals with a specific handheld programmer we provide. Main Technical Parameters Explosiveproof grade: [Ex ia] IIC Permissible input signal from hazardous area: /wire RTD resistance: Pt00, Cu00, Cu0, BA, BA etc. Linear resistance: 40~400Ω Signal type and range can be specified at your order and may also be programmed by user. Output signal to safe area: DC current: 0~0mA, 4~0mA, 0~0mA DC voltage: 0~V, ~V, 0~0V : resistance repeating Signal type and range can be specified at your order and may also be programmed by user. Transmitting accuracy for RTD (at o C± o C, without temperature compensation): If measurable range <00 o C: ±0. o C; For linear resistance: Accuracy reduces in proportion to Im. e.g.: ma Im ma: Rm < 0. Ω 0.mA Im < ma: Rm < 0. Ω 0.mA Im<0. ma: Rm < 0.4 Ω Rise time: s (bounce from 0%~90%) Influence of ambient temperature: <0ppm/ o C Lead resistance: 0 Ω per lead Output load capacity: DC current: 0~0mA: 0~700 Ω; 4~0mA: 0~0 Ω DC voltage: 0() ~ V: MΩ; 0~0V: MΩ If measurable range 00 o C: ±0.%F S Parameters certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST): Um=0 V AC/DC Between terminal &, & ; and terminal 4&, 4&: Uo=. V, Io=9.7 ma, Po=.8 mw IIC: Co=7. μf, Lo=4 mh IIB: Co=99 μf, Lo=79 mh IIA: Co=700 μf, Lo=000 mh

11 Products Overview RTD Signal Input / Output Type Dielectric strength: 00 V AC( Input /Output /, ma leakage current, minute test time) Insulation coordination: 00MΩ (Input/Output/) Electromagnetic compatibility: IEC 0004 : 8~ V DC (Recommended voltage: 4 V DC) Power consumption: 0.4W (4V power supply, 0mA single output) 0.W (4V power supply, 0mA double output) Panel Light Indication Light indicating: (green) remains illuminated during normal operation; Light indicating: (red) glitters or remains illuminated when signal fault occurs. Calibration The product is of intelligent digital design and the accuracy can be maintained within the range specified in this manual. If calibration is required, it shall be realized by the handheld programmer we provide. Model Selection Code Lists: Model Note NPEXAC x x x x Isolated safety barrier Single loop as default Input loop D Double loop 4~0mA ~V 0~0mA st output 4 0~V 0~0V 0~0mA 7 : resistance repeating None as default 4~0mA ~V nd 0~0mA output 4 0~V 0~0V 0~0mA 7 : resistance repeating None as default T 48 communication (single output only) Communication / Alarm function (not coexists with nd T communication (single output only) output) A Single relay alarm output A Double relay alarm output Note: Thermal resistance input type and the corresponding output range need to be specified when placing order. If you need to program by yourself, please operate with computer or the handheld programmer we provide.

12 Products Overview RTD Signal Input / Output Type Wiring Diagram wire resistance Input RTD wire resistance RTD Output 7 Output wire wire resistance resistance Input RTD RTD wire wire resistance resistance 4 Input RTD RTD Output 4V 4V Output 4 wire resistance Input RTD wire resistance RTD : resistance output : resistance output Dimension W H D (.8 00 ) mm W H D ( )mm 7.8mm.8mm 00mm 4 mm wire resistance Input RTD wire resistance RTD : resistance output 4~0mA output Installation Method Standard mm DIN rail installation, attention that position shall be stable and firm. In order to facilitate the heat of the instrument, Please mounted it vertically if possible Output wire resistance Input RTD wire resistance Input RTD wire resistance RTD wire resistance RTD D R 7 A 8 B Output Relay output Relay output 0~0mA output Operation Conditions Installation position shall not be affected by strong mechanical vibration, impact and electromagnetic induction from signal terminal and power supply, should conformity with the requirements on electromagnetic interference resistance of products in Class industrial field atmosphere stipulated in IEC 0004, and the atmosphere shall be free from gases that are corrosive to metal and plastic components. Supplementary Information If there is any content difference between the specification and the website or sample, this specification shall prevail. We reserve the rights to change or update the product information without prior noticing the users.

13 Products Overview Current Signal Input Type Referenced Model NPEXACM NPEXACM NPEXACMH This type of isolated safety barrier transmits current or voltage signals from safe area to hazardous area by isolating transmitting current signals in a circuit or two isolated circuits. The step response for this series is very quick, independent power supply is necessarily. The input, output, and power supply are galvanically isolated from each other. Main Technical Parameters Explosiveproof grade: [Exia] IIC Transmitting accuracy: ±0.%F.S( o C± o C) Influence of ambient temperature: <0ppm/ o C Rise time: 0.ms (bounce from 0%~90%) Settling time: ms Ripple: < mv Permissible input signal from hazardous area: DC: 4~0mA Signal type and range can be specified at your order. Output signal to safe area: DC current: 0~0mA, 4~0mA, 0~0mA Signal type and range can be specified at your order. Output load capacity: DC current: 0~0mA:.KΩ; 0(4)~0mA: 00Ω Parameters certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST): Um=0VAC/DC Between terminal & and terminal 4 & : Uo=.V, Io=8mA, Po=mW IIC: Co=0.074μF, Lo=.4mH IIB: Co=0.7μF, Lo=0.mH IIA: Co=.0μF, Lo=7.mH Dielectric strength: 00V AC(Input/Output/, ma leakage current, min test time) Insulation coordination: 00MΩ (Input/Output/) Electromagnetic compatibility: IEC 0004 : 8~V DC (Recommended voltage:4v DC) Power consumption: 0.8W (single input, 0mA single output).w (double input, 0mA double output)

14 Products Overview Current Signal Input Type Panel light indication: Light indicating: (green) remains shining during normal operation. Model Indication Model Note NPEXBCM x x x x Analog current output Isolated safety barrier Single loop as default Input loop D Double loop Input st output nd output 4~0mA ~V 0~0mA 4 0~V 0~0V 0~0mA 4~0mA 0~0mA 0~0mA None as default 4~0mA 0~0mA 0~0mA Wiring diagram: Dimension W H D (.8 00 ) mm W H D ( ) mm 7.8mm.8mm 00mm ma Input 4~0mA output I P 9 mm 0 Output I P 4 Output I P 7 ma Input 8 0 ma Input 4 Ambient Conditions Ambient temperature range: 0 o C~0 o C Relative humidity: 0%RH~90%RH (40 o C) Atmospheric pressure: 80kPa~0kPa Storage and delivery temperature: 40 o C ~80 o C Installation method Standard mm DIN rail installation, attention that position shall be stable and firm. In order to facilitate the heat of the instrument, Please mounted it vertically if possible.

15 Products Overview Voltage Signal Input / Output Type Referenced Model NPEXACM4 NPEXACM4 NPEXACM4D This type of isolated safety barrier transmits voltage signals from hazardous area to safe area by isolating transmitting current or voltage signals in a circuit or two isolated circuits, and it may also provide power to transmitters. The step response for this series is very quick, independent power supply is necessarily. The input, output, and power supply are galvanically isolated from each other. Main Technical Parameters Explosion protection sign: [Exia] IIC Transmitting accuracy: ±0.%F.S ( o C± o C). Influence of ambient temperature: <0ppm/ o C. Rise time: 0.ms (bounce from 0%~90%). Settling time: ms. Ripple: <mv. Frequency range: 0~00Hz. Permissible input signal from hazardous area: DC: 0~V, ~V, 0~0V. Signal type and range can be specified at your order and may also be programmed by user. Input resistance: MΩ. Available voltage: Not more than 4V for noload, not less than.v for full load. Output signal to safe area: DC current: 0~0mA, 4~0mA, 0~0mA. DC voltage: 0~V, ~V, 0~0V. Signal type and range can be specified at your order and may also be programmed by user. Output load capacity: DC current: 0(4)~0mA: 0Ω; DC voltage: 0()~V: MΩ; 0~0mA: 700Ω; 0~0V: MΩ. Parameters certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST): Um=0VAC/DC. Between terminal & and terminal 4 & : Uo=.7V, Io=mA, Po=0.mW IIC: Co=0.μF, Lo=000mH IIB: Co=.0μF, Lo=000mH IIA: Co=.μF, Lo=000mH Between terminal & and terminal 4 & : Uo=V, Io=mA, Po=7mW IIC: Co=0.μF, Lo=.9mH IIB: Co=0.89μF, Lo=4.77mH IIA: Co=.4μF, Lo=.7mH Dielectric strength: 00V AC(Input/Output/, ma leakage current, min test time).

16 Products Overview Voltage Signal Input / Output Type Insulation coordination: 00MΩ (Input/Output/). Electromagnetic compatibility: IEC : 8~V DC (Recommended voltage: 4V DC). Power consumption: 0.4W (single voltage input, 0mA single output) 0.W (single voltage input, 0mA double output).w (double voltage input, 0mA double output) Panel light indication: Light indicating: (green) remains shining during normal operation. Model Selection Code Lists: Model Note NPEXACM4 x x x Analog voltage input Isolated safety barrier Single loop as default Input loop D Double loop 4~0mA ~V st 0~0mA output 4 0~V 0~0V 0~0mA None as default 4~0mA ~V nd output 0~0mA 4 0~V 0~0V 0~0mA Dimension: W H D (.8 00 ) mm W H D ( ) mm 7.8mm.8mm 00mm Installation method Standard mm DIN rail installation, attention that position shall be stable and firm. In order to facilitate the heat of the instrument, Please mounted it vertically if possible. mm

17 Products Overview Voltage Signal Input / Output Type Wiring diagram: Hazardous area Input V Distribution Output 9 0 Operation conditions Installation position shall not be affected by strong mechanical vibration, impact and electromagnetic induction from signal terminal and power supply, should conformity with the requirements on electromagnetic interference resistance of products in Class industrial field atmosphere stipulated in IEC 0004, and the atmosphere shall be free from gases that are corrosive to metal and plastic components. Hazardous area Input V 7 Output Supplementary information If there is any content difference between the specification and the website or sample, this specification shall prevail. We reserve the rights to change or update the product information without prior noticing the users. Output Distribution 8 9 Power Supply 0 Hazardous 4V DC,single input, Safe single area or double output area 7 Input V 8 9 Distribution 0 Output Output Input 4 V 4 Distribution Ambient conditions Operating temperature range: 0~0 o C Relative humidity: 0%~90%RH Operating atmosphere pressure: 80~0kPa Storage and delivery temperature: 40~80 o C

18 Products Overview Switch Signal Input / Output Type Referenced Model NPEXAC NPEXAC NPEXAC This isolated barrier is used for intrinsic safety applications. It supplies power from nonhazardous area to small power consumption intrinsically safe apparatus in hazardous area by dry contacts, electrode and logic level signal. They are applicable to such intrinsically safe apparatus as solenoids, LEDs, and audible alarms. The input, output and the power supply ports are galvanically isolated from each other. Main Technical Parameters Explosiveproof grade: [Ex ia] IIC Permissible input signal from hazardous area: Dry contact input; Electrode input; Logical input: ON signal: V~0V, providing power to field apparatus; OFF signal: 0V~V, open input. Output signal to nonhazardous area: Solenoids or audible alarms driven by ma current Maximum output voltage: V Minimum output voltage: V Output current limit: ma output; Parameter certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST): Um=0V AC/DC Between terminals &, terminals 4 & : Uo=.V, Io=8mA, Po=mW IIC: Co=0.074μF, Lo=.4mH IIB: Co=0.7μF, Lo=0.mH IIA: Co=.0μF, Lo=7.mH Dielectric strength: 00V AC (Input /Output /, ma leakage current, minute test time) Insulation coordination: 00MΩ (Input /Output /) Electromagnetic compatibility: IEC 0004 : 8~V DC (Recommended voltage: 4V DC) Power consumption:.0w (single input, single output).0w (double input, double output)

19 Products Overview Switch Signal Input / Output Type Output equivalent circuit diagram V(min.) 00 Ohm(max.) Dimension W H D (.8 00 ) mm W H D ( ) mm 7.8mm.8mm 00mm ma 危险区信号输出等效电路 Output signal characteristic diagram U(V) E:Curve angle point (UE, IE) mm E I(mA) 危险区信号输出特性图 Wiring diagram Input Installation Method Standard mm DIN rail installation, attention that position shall be stable and firm. In order to facilitate the heat of the instrument, Please mounted it vertically if possible. Output CH CH CH CH 0 CH CH CH CH CH CH CH CH CH CH NPEXBC Single input & single output Output Output NPEXBCD 4 Double input & double output Power Supply Input Input Panel Light Indication Light indicating: Power indicator (green). It remains illuminated during normal operation; Light indicating (single channel): output signal status indicator CH (red). It remains illuminated when there is output signal. Light indicating (double channel): output signal status indicators CH and CH (red). The corresponding indicator turn on when output signal. Ambient Conditions Ambient temperature range: 0 o C~0 o C Relative humidity: 0%RH~90%RH(40 o C) Atmospheric pressure: 80kPa~0kPa Storage and delivery temperature: 40 o C~80 o C Operation Conditions Installation position shall not be affected by strong mechanical vibration, impact and electromagnetic induction from signal terminal and power supply, should conformity with the requirements on electromagnetic interference resistance of products in Class industrial field atmosphere stipulated in IEC 0004, and the atmosphere shall be free from gases that are corrosive to metal and plastic components.

20 Products Overview Frequency Signal Input / Output Type Referenced Model NPEXAC NPEXAC NPEXACA This type of product transmits 0~0KHz frequency signal from hazardous area to safe area by isolating transmitting current, voltage or frequency signals in a circuit or two isolated circuits, and it may also provide power to apparatus in hazardous area. The input, output and the power supply is galvanically isolated from each other. Besides, it may be connected in a connection network in safe area via communication ports. As an intelligent product, it has an online selfdiagnosis function. Customer may set the type and the range of the input or output signals with a specific handheld programmer (display in Chinese) we provide. Main Technical Parameters Explosiveproof grade: [Exia] IIC Transmitting accuracy: ±0.%F.S ( o C± o C) Influence of ambient temperature: <0ppm/ o C Rise time: 0.s (current or voltage output) μs (frequency output) Permissible input signal from hazardous area: Frequency: 0~0 khz (for analogue output) Frequency: 0~0 khz (for frequency output) Switching trigger point: Low level: 0~V; High level: 4~0V; Input resistance: kω Distribution voltage: 4V Distribution current: Output signal to safe area: 4V, not less than V when loaded with 0mA. DC current output: 0~0mA, 4~0mA, 0~0mA; DC voltage output: 0~V, ~V, 0~0V; : frequency output: open collector emitter follower logic level Open collector: high level: Vcc( 0V); low level: V; drive current: 0mA Emitter follower: high level: VccV; low level: 0.V; drive current: 0mA Logic level: High level: 8V VH 4V; Load resistance: kω (4V system) Output load capacity: DC current: 0~0mA: 700Ω; 4~0mA: 0Ω; DC voltage: 0()~V: MΩ; 0~0V: MΩ. : 8~ V DC (Recommended voltage: 4 V DC) low level: VL V;

21 Products Overview Frequency Signal Input / Output Type Power consumption: 0.8W (single voltage input, 0mA single output).0w (single voltage input, 0mA double output) Parameters certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST): Um=0VAC/DC Between terminal & : Uo=.8V, Io=0.7mA, Po=4mW IIC: Co=0.μF, Lo=7mH IIB: Co=.0μF, Lo=mH IIA: Co=8.μF, Lo=000mH Between terminal & : Uo=.8V, Io=0mA, Po=4mW IIC: Co=0.μF, Lo=mH IIB: Co=.0μF, Lo=mH IIA: Co=8.μF, Lo=mH Dielectric strength: 00 V AC (Input/Output/, ma leakage current, minute test time) Insulation coordination: 00 MΩ (Input /Output /) Electromagnetic compatibility: IEC 0004 Model Selection Code Lists: Model Note NPEXAC Frequency input isolated safety barrier Single as default Input D Double loop 4~0mA ~V 0~0mA Output 4 0~V 0~0V 0~0mA 7 : frequency None as default 4~0mA ~V 0~0mA Output 4 0~V 0~0V 0`0mA 7 : frequency Note: V or 4 V distribution voltage need to be specified at your order.

22 Products Overview Frequency Signal Input / Output Type Wiring Diagram Hazardous area Input Frequency Distribution Hazardous area Output Output Calibration The product is of intelligent digital design and accuracy can be maintained within the range specified in this manual. If calibration is required, it shall be realized by the handheld programmer we provide. Installation Method mm rail mounting: attention that position clamping is stable and firm. Vertical position shall be kept as possible to facilitate heat dispersion. : frequency output Input Frequency Distribution : frequency output Vcc Vcc RL RL RL Dimensions W H D (.8 00 ) mm W H D ( ) mm 7.8mm.8mm mm 00mm Operation Conditions Installation area shall not be affected by strong mechanical vibration, impact or electromagnetic induction, heavy current, spark and the like from signal terminal and power supply, and the atmosphere shall be free from gases that are corrosive to metal and plastic components. Supplementary Information If there is any content difference between the specification and the website or sample, this specification shall prevail. We reserve the rights to change or update the product information without prior noticing the users. Panel Lights Indication Light indicating: (green) remains illuminated during normal operation; Light indicating: (red) glitters or remains illuminated when signal fault occurs. Ambient Conditions Operating temperature range: 0 o C~0 o C Relative humidity: 0% RH ~90%RH Operating atmosphere pressure: 80 kpa ~0kPa Storage and delivery temperature: 40 o C ~80 o C

23 Products Overview Communication Signal Input / Output Type Referenced Model NPEXAC7 This type of isolated safety barrier can transmit communicational digital signals (half duplex RS48) from hazardous area to safe area. And it may also be connected in a connection network in safe area via communication ports. Besides, it may also provide power to the apparatus on the spot. This product needs an independent power supply. It is an excellent product with online selfdiagnosis function. The input, output, and power supply are galvanically isolated from each other. Main Technical Parameters Explosiveproof grade: [Ex ia] IIC Permissible input signal from hazardous area: Communicational digital signal: RS48 (HDX) Input signal level rule: Standard differential RS48 level Available voltage: Open circuit voltage greater than 0V, & not less than V when loaded with 0mA Output signal to safe area: Communicational digital signal: RS48 Output signal level rule: Standard differential RS48 level Transmitting delay: 0μs Transmitting rate:. kbps Control mode: Halfduplex Safety parameter certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST): Um=0VAC/DC Between terminals & : Uo=7.7V, Io=9mA, Po=7mW IIC: Co=.8μF, Lo=.mH IIB: Co=0μF, Lo=48.9mH IIA: Co=700μF, Lo=0.4mH Between terminals & 4: Uo=.V, Io=49mA, Po=8mW IIC: Co=0.μF, Lo=.mH; IIB: Co=0.7μF, Lo=.mH; IIA: Co=.7μF, Lo=8.8mH Dielectric strength: 00V AC (Input /Output /, ma leakage current, minute test time) Insulation coordination: 00MΩ (Input /Output /) Electromagnetic compatibility: IEC 0004 : 8~V DC (Recommended voltage: 4V DC) Power consumption:.w

24 Products Overview Communication Signal Input / Output Type Wiring Diagram Hazardous area RS48 input A B R D D R A B RS48 output Installation Method Standard mm DIN rail installation, attention that position shall be stable and firm. In order to facilitate the heat of the instrument, Please mounted it vertically if possible. 9 Distribution Power Supply 4 0 COM COM COM COM COM COM Single RS48 input,single RS48 output, HDX mm Dimensions W H D (.8 00 )mm.8mm mm 00mm Operation Conditions Installation position shall not be affected by strong mechanical vibration, impact and electromagnetic induction from signal terminal and power supply, should conformity with the requirements on electromagnetic interference resistance of products in Class industrial field atmosphere stipulated in IEC 0004, and the atmosphere shall be free from gases that are corrosive to metal and plastic components. Panel light Indication Light indicating: (green) remains illuminated during normal operation; Light indicating: COM (red) glitters when the occurrence of data exchange, or else, It is out. Ambient Conditions Operating temperature range: 0 o C~0 o C Relative humidity: 0% RH~90% RH (40 o C) Operating atmospheric pressure: 80 kpa~0 kpa Storage and delivery temperature: 40 o C~80 o C Supplementary Information If there is any content difference between the specification and the website or samples, this specification shall prevail. We reserve the rights to change or update the product information without prior noticing the users.

25 Products Overview Eddy Current Signal Input / Output Type Referenced Model NPEXAC87 This isolated safety barrier can detect and transmit the output signal of eddycurrent transducer from hazardous area to safe area by repeating the input signal. Meanwhile, it provides isolated power to field apparatus in hazardous area. The input, output, and power supply are galvanically isolated from each other. Main Technical Parameters Explosiveproof grade: [Exia] IIC Permissible input signal from hazardous area: 0~ 0.V AC Input impedance: 0kΩ Output signal to safe area: 0~ 0.V AC Output resistance: <Ω DC transmitting accuracy: <±0mV AC transmitting accuracy: 0 Hz~ khz: ±%; khz~ 0 khz: %~ %. Temperature shift: <0ppm/ o C Voltage stability bandwidth: < 0.dB (at khz) < db (at 0 khz) Phase response: <0μs, equivalent to: 0.7º at 00 Hz; º at 00 Hz;.º at khz; º at 0 khz; 7º at 0 khz; 80º at 0 khz; Distribution voltage: When open circuit voltage is 4V and distribution voltage is 9.V, the full load current is greater than or equal to ma. Safety parameter certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST): Um=0 VAC/DC Between terminal & : Uo=. V, Io=0. ma, Po=0.0 mw IIC: Co=70 μf, Lo=000 mh; IIB: Co=700 μf, Lo=000mH; IIA: Co=700 μf, Lo=000 mh Between terminal & : Uo= V, Io=87. ma, Po=70 mw IIC: Co=0.09 μf, Lo=. mh; IIB: Co=0. μf, Lo=9. mh; IIA: Co=.8 μf, Lo=. mh Dielectric strength: 00 V AC (Input /Output /, ma leakage current, minute test time) Insulation coordination: 00 MΩ (Input /Output /) Electromagnetic compatibility: IEC 0004 : 8~ V DC (Recommended voltage:4v DC) Power consumption:. W

26 Products Overview Eddy Current Signal Input / Output Type Wiring Diagram Operation Conditions Installation position shall not be affected by strong Eddy current sensor input Common Signal VT Power Dimension W H D (.8mm 00mm mm) (0V) 9 0 0~0.V DC output mechanical vibration, impact and electromagnetic induction from signal terminal and power supply, should conformity with the requirements on electromagnetic interference resistance of products in Class industrial field atmosphere stipulated in IEC 0004, and the atmosphere shall be free from gases that are corrosive to metal and plastic components. Supplementary Information If there is any content difference between the specification and the website or samples, this specification shall prevail. We reserve the rights to change or update the product information without prior noticing the users. 7.8mm.8mm 00mm mm Panel light Indication Light indicating: (green) remains glitters during normal operation. Ambient Conditions Operating temperature range: 0 o C~0 o C Relative humidity: 0%RH~90%RH (40 o C) Operating atmospheric pressure: 80kPa~0kPa Storage and delivery temperature: 40 o C~80 o C Installation Method Standard mm DIN rail installation, attention that position shall be stable and firm. In order to facilitate the heat of the instrument, Please mounted it vertically if possible. 4 4

27 Products Overview Magnetic Resistance Signal Input / Output Type Referenced Model NPEXAC89 This isolated safety barrier can detect and transmit the output voltage signal of magnetoresistive transducer from hazardous area to safe area by repeating the input signal. The input, output, and power supply are galvanically isolated from each other. Main Technical Parameters Explosiveproof grade: [Ex ia] II C Direct current transmitting accuracy: ±0.%F S ( o C± o C) Direct current transmitting accuracy: ±0.%F S ( o C± o C) Permissible input signal from hazardous area: 0~0V AC (magnetoresistive transducer output signal) Input impedance: 0kΩ Output signal to safe area: 0~0V AC (: repeating signal) Output resistance: <0Ω Voltage stability bandwidth: 0.dB (at khz) db (at khz) Safety parameter certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST): Um=0VAC/DC Between terminal & : Uo=8.V, Io=4mA, Po=8.mW IIC: Co=0.0μF, Lo=000mH IIB: Co=.9μF, Lo=000mH IIA: Co=μF, Lo=000mH Dielectric strength: 00V AC (Input/Output/, ma leakage current, minute test time) Insulation coordination: 00MΩ (Input/Output/) Electromagnetic compatibility: IEC 0004 : 8~V DC (Recommended voltage: 4V DC) Power consumption: 0. W

28 Products Overview Magnetic Resistance Signal Input / Output Type Wiring Diagram Installation Method Standard mm DIN rail installation, attention that position Magnetoresistive Transducer Input 9 0 0~0V AC output shall be stable and firm. In order to facilitate the heat of the instrument, Please mounted it vertically if possible. Warning: because of high output resistance requirement, short circuit of output ports is prohibited. 4 4 Dimension W H D (.8mm 00mm mm) 7.8mm.8mm 00mm mm Operation Conditions Installation position shall not be affected by strong mechanical vibration, impact and electromagnetic induction from signal terminal and power supply, should conformity with the requirements on electromagnetic interference resistance of products in Class industrial field atmosphere stipulated in IEC 0004, and the atmosphere shall be free from gases that are corrosive to metal and plastic components. Panel light Indication Light indicating: (green) remains illuminated during normal operation. Ambient Conditions Operating temperature range: 0 o C~0 o C Relative humidity: 0%RH~90%RH (40 o C) Operating atmospheric pressure: 80kPa~0kPa Storage and delivery temperature: 40 o C~80 o C Supplementary Information If there is any content difference between the specification and the website or samples, this specification shall prevail. We reserve the rights to change or update the product information without prior noticing the users.

29 Products Overview Magnetoelectronic Signal Input / Output Type Referenced Model NPEXAC88 NPEXAC887 This isolated safety barrier can detect and transmit the output signal of magnetoelectric transducer from hazardous area to safe area by repeating the input signal. The input, output, and power supply are galvanically isolated from each other. Main Technical Parameters Explosiveproof grade: [Exia] IIC Transmitting accuracy: ±0.%F S ( o C± o C) Permissible input signal from hazardous area: 0~0V AC Input impedance: 0kΩ Output signal to safe area: 0~0V AC Output resistance: <0Ω Voltage stability bandwidth: 0.dB (at khz) Vibration frequency range: Hz~00Hz Safety parameter certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST): Um=0VAC/DC Between terminal & : Uo=8.V, Io=4mA, Po=8.mW IIC: Co=0.0μF, Lo=000mH IIB: Co=.9μF, Lo=000mH IIA: Co=μF, Lo=000mH Dielectric strength: 00V AC (Input/Output/, ma leakage current, minute test time) Insulation coordination: 00MΩ (Input/Output/) Electromagnetic compatibility: IEC 0004 : 8~V DC (Recommended voltage: 4V DC) Power consumption: 0. W

30 7.8mm Products Overview Magnetoelectronic Signal Input / Output Type Wiring Diagram Operation Conditions Installation position shall not be affected by strong Magnetoelectric sensor Input Dimension W H D (.8mm 00mm mm).8mm mm 00mm 9 0 0~0V AC output mechanical vibration, impact and electromagnetic induction from signal terminal and power supply, should conformity with the requirements on electromagnetic interference resistance of products in Class industrial field atmosphere stipulated in IEC 0004, and the atmosphere shall be free from gases that are corrosive to metal and plastic components. Supplementary Information If there is any content difference between the specification and the website or samples, this specification shall prevail. We reserve the rights to change or update the product information without prior noticing the users. Panel light Indication Light indicating: (green) remains glitters during normal operation. Ambient Conditions Operating temperature range: 0 o C~0 o C Relative humidity: 0%RH~90%RH (40 o C) Operating atmospheric pressure: 80kPa~0kPa Storage and delivery temperature: 40 o C~80 o C Installation Method Standard mm DIN rail installation, attention that position shall be stable and firm. In order to facilitate the heat of the instrument, Please mounted it vertically if possible. 4 4

31

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.: Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

onlinecomponents.com

onlinecomponents.com Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common

More information

Temperature measurement TMD 832 head transmitter

Temperature measurement TMD 832 head transmitter Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Assembly. Front view. HiC2441. SL2 1b. Termination Board SMART Universal Barrier HiC Features Assembly channel isolated barrier V DC supply (bus powered) Analog input, digital input, analog output, digital output No configuration required, device is selfadapting

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

RMA42. Technical Information

RMA42. Technical Information Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and

More information

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features: Characteristics: Front Panel and Features: Ordering Information: Model: D7 D7 General Description: The single and dual channel DIN Rail Temperature Signal Converter D7S and D7D accepts a low level dc signal

More information

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461 October 13, 2017 Annexe to: IECEx CML 15.0063X Issue 1 Applicant: Apparatus: Braun GmbH Isolating Amplifier D461 Description The Isolating Amplifier D461 is an intrinsic safety associated apparatus

More information

S200 I/O System Units

S200 I/O System Units S200 I/O System Units S200 I/O is a range of cost effective I/O units which are bus compatible with S200L I/O and can be mixed with them in any order on the same DIN rail. The S200 I/O System features

More information

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm

More information

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Linearized 4-Wire RTD Input 5B35 FEATURES Single-channel signal conditioning module that Amplifies, Protects, Filters, and Isolates Analog Input. Isolates and protects a wide variety of four-wire

More information

Universal Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version

More information

Safety Instructions Nivotester FTC625, FTC325

Safety Instructions Nivotester FTC625, FTC325 XA01351F-A/00/EN/01.14 71273077 Products Solutions Services Safety Instructions FTC625, FTC325 [Ex ia Ga] IIC/IIB TÜV 13.0903 X Segurança TÜV INMETRO OCP 0004 Document: XA01351F-A Safety instructions for

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

STT 3000 Smart Temperature Transmitter Series STT170 Specifications STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable

More information

itemp HART DIN rail TMT112

itemp HART DIN rail TMT112 Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application

More information

Assembly. Front view. Power Rail

Assembly. Front view. Power Rail Thermometer Resistance Repeater Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) RTD/resistance input Resistance output Accuracy 0.1 % Front view Removable terminals blue Function

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194 DIN Rail Devices Description DIN rail devices serve as low cost signal conditioning modules between the field device and the control system. The new enclosures mounted on the 35 mm standard rail are equipped

More information

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional

More information

2002 IS Catalog. Page

2002 IS Catalog. Page Page Introduction... 95 Current Repeaters/Drivers (Single-channel) KFD0-CS-Ex1.50P (Transmitter, positioner and indicator)... 96 KFD0-CS-Ex1.51P (Positioner and fire detector)... 97 KFD0-CS-Ex1.52 (Current

More information

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Frequency Input 5B45 / 5B46 FEATURES Isolated Frequency Input. Amplifies, Protects, Filters, and Isolates Analog Input. Generates an output of 0 to +5V proportional to input frequency. Model

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Technical Information RMA42

Technical Information RMA42 TI00150R/09/EN/05.16 71315973 Products Solutions Services Technical Information RMA42 Process transmitter with control unit Digital process transmitter for monitoring and visualizing analog measured values

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC

More information

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol SIL IEC 6 508 Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol Data Sheet 0068_en_03 PHOENIX CONTACT 0-07-09 Description Temperature FL ϑ Universal PC programmable

More information

MTL4000 SERIES. isolating IS interface units. For close integration of IS circuits into processconnected

MTL4000 SERIES. isolating IS interface units. For close integration of IS circuits into processconnected For close integration of S circuits into processconnected systems 1 MTL4000 SERES isolating S interface units Compact modular design with plug-in connections High module/channel packing densities System

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

High-precision process calibrator Model CED7000

High-precision process calibrator Model CED7000 Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry

More information

SELECTION GUIDE. Interfaces galvanic insulation.

SELECTION GUIDE. Interfaces galvanic insulation. SELECTION GUIDE Interfaces galvanic insulation 1. and notions of intrinsic safety 1. 4 2. Notions of intrinsic safety 7 2. 1. Mechanical properties 12 2. Certifications 12 3. Dimensions 12 3. Selection

More information

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2] Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication) Functions & Features Universal input: DC mv, T/C, RTD and resistance High accuracy HRT communication

More information

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp PCP TMT 181 Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

AI-501 INTELLIGENT INDICATING/ALARMING INSTRUMENT. Operation Instruction

AI-501 INTELLIGENT INDICATING/ALARMING INSTRUMENT. Operation Instruction AI-501 INTELLIGENT INDICATING/ALARMING INSTRUMENT Operation Instruction CONTENTS Page MAIN FEATURES... 2 ORDERING CODE.3 TECHNICAL SPECIFICATION.5 FRONT PANEL AND OPERATION..6 PARAMETER AND SETTING...

More information

Temperature Transmitters TMT 136, TMT 137

Temperature Transmitters TMT 136, TMT 137 Technical Information TI 066R/09/en Part No. 51000855 Temperature Transmitters TMT 136, TMT 137 For Pt100 Resistance Thermometers 2-wire head transmitter Standard- and instrinsically safe versions Head

More information

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO

More information

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature Transmitter itemp RTD DIN rail TMT 127 Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

PRetrans Table of contents

PRetrans Table of contents HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting

More information

FC-33, DC SELECTABLE SIGNAL CONDITIONER

FC-33, DC SELECTABLE SIGNAL CONDITIONER FC-33, DC SELECTABLE SIGNAL CONDITIONER Description. The FC-33 is a DIN rail or side mount, selectable input/output signal conditioner with 1500VDC isolation between input and output, and 1500VDC isolation

More information

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

Universal Intelligent 2-wire In-head Transmitters

Universal Intelligent 2-wire In-head Transmitters Universal Intelligent 2-wire In-head Transmitters Actual size IPAQ-H is a universal and intelligent 2-wire In-head transmitter for temperature and other measurement applications. IPAQ-HX is the Intrinsic

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

TxBlock-USB Transmitter

TxBlock-USB Transmitter Transmitter TEMPERATURE TRANSMITTER - OPERATING MANUAL V1.0x I INTRODUCTION The TxBlock-USB is a 4-20 ma 2-wire temperature transmitter for head mount, powered by the current loop. The output current is

More information

P5201 Universal Programmable Transmitters with Galvanic Isolation

P5201 Universal Programmable Transmitters with Galvanic Isolation Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to

More information

Universal Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version

More information

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically

More information

SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Temperature Transmitter ZTT series

Temperature Transmitter ZTT series BT.11.13 ZT/I ZTT series The ZTT series transmitter accepts the most commonly used temperature sensors (RTD, T/C) as well as mv and slide wire signals. All the models adopt a 2 wire 4...20mA output signal

More information

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. Parametrization interface. Power Bus Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

A6500-UM Universal Measurement Card

A6500-UM Universal Measurement Card Specifications Sheet A6500-UM Universal Measurement Card The A6500-UM Universal Measurement Card is a component of the CSI 6500 ATG machinery protection system. The card is equipped with 2 sensor input

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

R88000 T (including ATEX)

R88000 T (including ATEX) INSTRUCTION MANUAL R88000 T88000 (including ATEX) Factory set transmitters are ready to use. Connect according the labels. Otherwise follow the calibration instructions. Input signals ṮC RTD CONTENTS:

More information

AI-700 / 500 INTELLIGENT INDICATING/ALARMING INSTRUMENT. Operation Instruction

AI-700 / 500 INTELLIGENT INDICATING/ALARMING INSTRUMENT. Operation Instruction AI-700 / 500 INTELLIGENT INDICATING/ALARMING INSTRUMENT Operation Instruction CONTENTS Page MAIN FEATURES... 2 ORDERING CODE.3 TECHNICAL SPECIFICATION.5 FRONT PANEL AND OPERATION..7 PARAMETER AND SETTING...

More information

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater D1035S INSTRUCTION MANUAL FrequencyPulse Isolating Repeater DIN Rail Model D1035S D1035 FrequencyPulse Isolating Repeater ISM007910 Characteristics General Description: The single channel DIN Rail FrequencyPulse

More information

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays KSR-Level sensor KSR-Schwimmer-Magnetschalter 1001-5 KSR Contact Protection s 1 KSR Contact Protection Type KR230-Ex and KR24-Ex General Description The contact protection relays KR230-Ex and KR24-Ex transmit

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0) Data Sheet KFD-UFC-EX1.D Supplied by.com Call us on +44 (0)118 916 940 Email info@47able.com Frequency Converter with Trip Values Features Assembly 1-channel isolated barrier 4 V DC supply (Power Rail)

More information

SINEAX / EURAX 2I1 Passive DC signal isolator

SINEAX / EURAX 2I1 Passive DC signal isolator SINEAX / EURAX I without power supply 0 II () G resp. II () G Application The DC signal isolator SINEAX/EURAX I (Figs. and ) serve to isolate load-independent DC current signals. It suppressed noise voltages

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright

More information

Rail mounted Temperature Transmitter TH102/TH102-Ex

Rail mounted Temperature Transmitter TH102/TH102-Ex Data Sheet 10/-8.54 EN Rail mounted Temperature Transmitter TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples

More information

General Specifications

General Specifications General I/O Adaptors (for N-IO) GS 33J62F30-01EN [Release 6] GENERAL This General (GS) describes the hardware specifications of I/O adaptors that enable extended functions setting for analog digital I/O

More information

Temperature head transmitter itemp TC TMT 188

Temperature head transmitter itemp TC TMT 188 Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed

More information

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes

More information

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply. Calibration. Surface finishing. Seal. Process connection Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters The 520 transmitters are universal, isolated, dual-input temperature transmitters with additional voltage and resistance

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

ONE CALIBRATOR ONLY MAIN FEATURES:

ONE CALIBRATOR ONLY MAIN FEATURES: ONE CALIBRATOR ONLY The MEMOCAL 2000 is a lightweight versatile, portable, hand-held calibrator developed to solve two different and coexisting customer needs: field calibration (maintenance) and laboratory

More information

Temperature Measurement

Temperature Measurement Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications

More information

General Specifications

General Specifications General Specifications FN510 Field Wireless Multi-Function Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Function Module. Combined with Field Wireless

More information

Temperature Transmitters - DIN Rail Mounted

Temperature Transmitters - DIN Rail Mounted XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and

More information

Head mounted Temperature Transmitter TF02/TF02-Ex

Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance

More information

ADAM 4000/4100 Series

ADAM 4000/4100 Series ADAM 4000/4100 Series Common Dimensions Communication RS-485 (2-wire) to host Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080, ADAM-4080D only support up to 38400 bps) Max. communication

More information

Coupling Relays and Converters

Coupling Relays and Converters Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For oils and fuels Model LF-1 Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run

More information

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For water and wastewater Model LW-1 Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and

More information