EVALUATION OF TOTAL WORKSTATION CT INTERPRETATION QUALITY: A SINGLE-SCREEN PILOT STUDY

Size: px
Start display at page:

Download "EVALUATION OF TOTAL WORKSTATION CT INTERPRETATION QUALITY: A SINGLE-SCREEN PILOT STUDY"

Transcription

1 EVALUATION OF TOTAL WORKSTATION CT INTERPRETATION QUALITY: A SINGLE-SCREEN PILOT STUDY Beard DY1'3, Perry JR1, Muller K2, Misra R3, Brown P3, Hemminger BM1, Johnston RE1, Mauro M1, Jaques P1, and Schiebler M1, Departments of Radiology1, BioStatistics2, and Computer Science3' University of North Carolina at Chapel Hill AB STRACT An interpretation report, generated with an electronic viewbox, is affected by two factors: Image quality, which encompasses what can be seen on the display, and computer human interaction (CIII), which accounts for the cognitive load effect of locating, moving, and manipulating images with the workstation controls. While a number of subject experiments have considered image quality, only recently has the affect of CIII on total interpretation quality been measured. This paper presents the results of a pilot study we conducted to evaluate the total interpretation quality of the FilmPlane2.2 radiology workstation for patient folders containing single forty-slice CT studies. First, radiologists interpreted cases and dictated reports using FilmPlane22. Requisition forms were provided. Film interpretation was provided by the original clinical report and interpretation forms generated from a previous experiment. Second, an evaluator developed a list offindings for each case based on those listed in all the reports for each case and then evaluated each report for its response on each finding. Third, the reports were compared to determine how well they agreed with one another. Interpretation speed and observation data was also gathered. 1. FILMPLANE2.2 Images CurrentExam ED äci Detail View 31 Slice CT Chest Exam Navigational View Figure 1 FilmPlane2.2 Viewport, Navigation View, and Detail Views. FilmPlane2.2, the latest FilmPlane prototype, continues to provide the user with a image index mental model [Beard 1990B] of a large two dimensional surface upon which are arrayed all the images in the patient's folder (see Figure 1). By imagining themselves "flying" over this surface, users can quickly learn how to access any image and scroll through the various examinations. FilmPlane2.2, imple- 52 / SPIE Vol Medical Imaging V PACS Design air! Evaluation (1991) /91/$4.00

2 mented using X 1 1, runs on UNIX workstations that support the X windowing system, such as DEC 3100s and Sun SPARCs. Users can move the viewport and corresponding detail view through the navigation view in two ways. First, they can toggle to the navigation view, grab the viewport with the mouse, and move it to a new location in the navigation view, moving the corresponding detail view. Second, they can scroll [Beard 1989, Walker 1990] sequentially through the images in an examination. The user could toggle the system to scroll in increments of either 256 or 512 pixels. FilmPlane2.2 also allows smooth scrolling. FilmPlane2.2 provides 12-bit dynamic intensity windowing with 8-bit framebuffers. Static intensity windowing is accomplished as follows: Every time an image is displayed, its 12-bit data (actually. stored as 16-bit data) is window-width-and-leveled [Pizer 1989] into 8-bit pixels using a lookup table before being moved to the framebuffer. Presets can be used to change the width and levels reflected by the lookup table (Figure 2). The choice of presets automatically changes as the user moves the cursor among the various modality studies in the patient's folder. IWBar Toggle Presetc Enablel Disable Default ST \ Liver Lung Brain Bone Intensity Window Bar Sliders Figure 2 Intensity-Windowing Bar and Presets Dynamic intensity windowing is a bit more complex(figure 2). When the intensity-window-widthand-level slider-bar (IWbar) is "enabled," the IWBar visually changes, the 12-bit image being displayed is linearly reduced into an 8-bit image, and the current 12-bit window-width-and-level settings are reflected as corresponding 8-bit values realized in the workstation's color map. Thus, while the IWbar is enabled, moving the bar actually changes the machine's color map in real time, showing an image that is very similar to the actual 12-bit windowed image. When the IWbar is disabled, the normal linear color map is restored, and the 12-bit intensity window values corresponding to the last 8-bit settings are used to re-display the correctly windowed image. Thus, this intensity window method allows the use of low-cost 8-bit framebuffers [Beard 1990A], while still facilitating dynamic windowing. 2. PILOT EXPERIMENT This study evaluated the relative interpretation accuracy of a single-screen FilmPlane2.2 radiology workstation to film for interpretation of forty-slice CT Chest studies. Our objectives were as follows: to determine whether any design changes were necessary to the FilmPlane2.2 computer-human interaction, to train a pool of radiologists to use FilmPlane, to evolve the experimental protocol, to provide SPIE Vol Medical Imaging V: PACS Design and Evaluation (199 1) / 53

3 data for power analysis estimates for the final experiment, and to obtain preliminary results on FilmPlane's effectiveness, relative to Film, with respect to image quality and interpretation task time. The workstation in question only used a single 1Kx1K monitor. While this is clearly inadequate, it did allow us to conduct a pilot study while the multiple screen version was begin completed. Since we were interested in total interpretation accuracy, rather than just image quality, we could not use a traditional "structured response form" [Johnston 1990] to gather accuracy responses, for the form's structure would affect the radiologist's work patterns, working memory load, etc., resulting in a non-clinical situation. Therefore, workstation interpretation results were gathered using dictated interpretation reports similar to [Foley 1990]. These reports from the workstation interpretations were compared against the interpretation report generated with film in the clinic, and against two detailed findings lists from [Johnston 1990] to compare the various findings noted by the radiologists using film and workstation. Workstation task times were compared to typical task times for interpreting similar cases in the clinic. 2.1 Method Subjects:Three board-certified Radiologists participated. Two had extensive CT chest experience, and the third was a senior chest radiologist with limited CT experience. In addition, three other radiologists read several cases allowing us to gather additional observations. All subjects are on the faculty of the University of North Carolina Department of Radiology. Cases: Nine patient image folders were used, each containing a 12-bit-per-pixel CT chest study consisting of from 36 to 47 slices. The attending physician's requisition forms were provided on paper. Apparatus: Images were interpreted on a one-screen version of the FilmPlane2.2 radiology workstation using a Sun 4/370 with 32 Megabytes of main memory, an 8-bit framebuffer and color monitor. A conventional dictation device was provided and a videotape system with a stop watch function was used to record times, hand and head motions, and verbal protocol. Procedure: A session started with the subject seated in front of the one-screen Sun workstation in the subject laboratory. Since one purpose of this pilot was to train subjects, only a very brief training period was provided. During training, the experimenter described the workstation metaphor, and demonstrated the basic interactions, taking about two minutes. Then the subjects, with coaching, navigated through test patient folders and adjusted contrast with presets and with the double-slider bar until they indicated they were ready to proceed. The entire training period was typically under five minutes. Case interpretation order was randomized, and each subject read each case. For each trial, a patient image folder containing a single CT case was presented with the navigation view initially displayed. The subject was instructed to interpret the study and dictate a report with the same professional standards of accuracy as use for clinical film interpretations. Data Analysis: An evaluator examined the six reports for each case, that is, the original clinical report, the two findings forms from [Johnston 1990], and the three dictated reports from this pilot study. For each case, he compiled a list consisting of the union of all findings from all reports on that case. If one report contained a more detailed version of the same finding, e.g. if one report stated "lung tumor" and a second "tumor in right lung," the evaluator listed all finding permutations, that is, one for a lung tumor, and the second for a tumor in the right lung. Finally, for each of the six reports and for each finding, the evaluator determined whether the report stated that a particular finding was present. Only findings which were available on the findings form used in [Johnston 1990], were considered in the data analysis. 54 / SPIE Vol 1446 Medical Imaging V. PACS Design and Evaluation (1991)

4 2.2 Results Subject A completed the training case and all nine cases in a single 3 hour session. It was clear that the last few cases were rushed, but the radiologist felt the results were still of clinically acceptable quality. Subjects B completed the training and the first four cases in one session, and the remaining five cases in a second session. Subject C completed the training and the first three cases in an initial session, and three cases each in two subsequent sessions Data Accuracy: Table 1 shows the amount of agreement between the findings of each pair of reports. Each entry shows the sum across all findings of the absolute value of the difference between each report's value for that finding, with "finding-present" valued as 1, and a "finding not present" valued as 0. This is equivalent to the "percent agreement" between these two reports. Average agreement for a given report, is the average of all five agreement-pair values in which that report participated. The average of all the workstation entries (SA, SB, and SC) is 0.32, which is the same (within two digits) as the average for all the film entries (CR, WA, JFB). CR SA SB SC JFA JFB Original Clinical Rpt (CR) 0 FilinPiane Subject A(OA).34 0 FilmPlane Subject B(OB) FilmPlane Subject C(OC) Johnston90 Form A (JFA) Johnston90 Form B (JAB Average Agreement Table 1 Agreement for each report pair, and average for each report. 20 t 16 m 12 e 8 SB SC 4 gi Sj 1 2 Task time Cases Figure 3 for each subject and each case. Time in minutes. SPIE Vol Medical Imaging V PACS Design arid Evaluation (1991) / 55

5 Interpretation Speed: Figures 3 and 4 show the task times for the FilmPlane subjects interpreting the various CT cases. Figure 3 shows the interpretation of each separate case. Subject C, not being a frequent interpreter of CT, was considerably slower. Figure 4 shows the task times for the cases in the order in which they were read. While subject C does not show any learning, subjects A and B - those who frequently interpret Chest CT exams - seem to reduce their task times over the 9 cases in this pilot study. These data, along with observations made by the experimenter, indicate that these two subjects were able to use their considerable CT experience to develop more efficient methods of interpretation. None of the subjects interpreted these CT cases as fast as is done in the clinic where a case is typically read in 2 or 3 minutes. The average interpretation time was 8 minutes and 13 seconds. The two frequent CT interpreters averaged 6 minutes 12 seconds overall, and 4 minutes and 50 seconds on the last three cases, which is still from 50% to 100% greater than typical clinical times. Subject C averaged 12 minutes 15 seconds over all the cases Time 1 Sc (Minutes) 8 4 SB SA c (In order read) Figure 4 Task time for each subject and each case in the order read. Time in minutes Observations and Subject Comments Learning: All subjects were able to use the system after only two minutes of instruction, followed by three minutes of interaction with assistance. Radiologists expressed confidence in their understanding of the interaction. The FilmPlane metaphor again proved useful, and the navigation view often was used to determine the radiologist's position in the examination, and for rapid access to remote anatomy. Slice ordering seemed critical to maintaining the metaphor. In one case the slices were in reverse order with the abdomen slices to the upper left and lung slices to the lower right. Radiologists had difficulty remembering which direction they needed to move in order to navigate to a desired anatomy. Scanning approaches: Subjects viewed the CT cases by anatomy, typically starting with an overview of the navigation view and scout view to see the extent of the examination, followed by a lung-preset scan of the lung, a soft-tissue-preset scan of the entire study, and a liver scan using the liver window. Then radiologists would typically go back and review critical anatomy with one or more intensity window settings. This took a long time, apparently because of the limited screen space. 56 / SPIE Vol Medical Imaging V PACS Design and Evaluation (1991)

6 Intensity windowing: In general, the subjects used the default presets for intensity windowing. However, there were a number of occasions in which they used the IWbar to choose an intensity window setting not available with the presets. It was noted that when a non-preset window was used, it was often repeatedly reacquired during that interpretation; it would be useful to have a mechanism allowing the subject to temporarily reset a preset to a new setting. In general, the dynamic intensity bar was successful, allowing 12-bit intensity windowing with only an 8-bit framebuffer. However, a few problems were encountered. First, when the bar was enabled, a very narrow intensity-window setting - such as a liver window - would produce a image that was far more "pixelly" than desirable. This was because an intensity window width of 100 intensity levels, which would produce an acceptable image, was reduced to a width of only about eight intensity levels. The image was, of course, correctly displayed when the bar was disabled and all 12-bits used. Second, the subjects sometimes forgot to disable the intensity window bar after selecting a new window setting. This could leave them with a less-than-optimal image. Navigation: Subjects were able to successfully navigate over the images in the patient folder. Random images were accessed using the navigation view by moving the viewports. Minor problems were encountered with grabbing the viewport. Mouse: There were problems with the optical mouse used in the experiment. When the mouse pad is square to the table, the arm of a right-handed radiologist is tilted slightly to the left, so that while the radiologist thought he was moving the mouse up and down, he was actually moving the mouse from 1 1 O'clock to 5 O'clock. Further, while most subjects dictated with the left hand while mousing with the right, one right-handed subject would keep the dictation microphone in the left hand when scrolling, and then switch it to the right for dictation. We observed that this had no significant impact on response time, and the radiologist did not comment on this as a problem. Screen Space: The single 1Kx1K screen was acceptable when merely scanning through a series of images. But when trying to understanding an anatomical abnormality that required more than four slices, the overhead required to scroll back and forth over a large number images was bothersome, time consuming, and invited errors caused by either not seeing something, not being able to correctly understand the 3D anatomical relationships, or simply forgetting to dictate critical abnormalities. Comments such as "I cannot see enough of the heart at the same time," were heard frequently. Response time: The typical response time of 1.5 seconds (for a scroll operation replacing 1/2 of the screen), seemed acceptable and radiologists often said it seemed fast. However one radiologist, when doing a screening scan through a sequence of images, would start the scroll operation before he had completely viewed the slices in question, thus anticipating the scroll. While it was good to see that the radiologist had developed an optimal strategy for using the workstation, it also indicated that a faster response time might be beneficial. Strained working memory : Several radiologists noted that they could not mentally keep track of items for dictation at the end of the interpretation as they normally did with film. All the radiologists started dictating midway through the interpretation, and two asked for pen and paper in order to take notes. Several noted that the typical CT interpretation method taught to residents -in which each organ group is individually viewed with the appropriate intensity windowing -while appropriate for film with its rapid sequential access, did not work with the slower sequential rates of a workstation. Several radiologists took so long on a case that they lost track of what had been completed. One noted "Did I look at the pancreas?", and another said "Did I see the kidneys?" Lack of Confidence: Despite the apparent acceptable accuracy of the dictated results, all the radiologists expressed a lack of confidence for the first few cases, and subject C, with the least amount of SPIE Vol Medical Imaging V: PACS Design arid Evaluation (1991) / 57

7 CT experience, expressed a lack of confidence throughout the experiment. One subject jokingly noted "My degree of confidence is low - I ain't got them in my hand." All subjects were unhappy with the lack of screen space. One noted, toward the end: "You do get into a pattern, but I don't enjoy it" Other Observations: First, one subject constantly touched the screen with his finger, leaving finger prints. We will either have to keep a lot of screen cleaner near by, or train him not to do this. Second, the scout view was critical, for counting ribs and locating findings. Third, several radiologists suggested the need for a tool to determine the intensity value of a particular pixel. Forth, several also requested a tool to measure the size of a mass. Fifth, the radiologists stated that they would like to have the postage-stamp images in the navigation view reflect the intensity window settings of the actual images: FilmPlane currently uses contrast-limited adaptive histogram equalization (CLAHE) [Zimmennan 1988, Pizer 1989] for the navigation view images. 3. CONCLUSIONS The FilmPlane metaphor again proved effective in providing a viable interaction that can be learned in under five minutes. Nevertheless, as we expected, it is clear that a single 1Kx1K screen is not enough for a primary diagnosis of even a single CT examination. Most importantly, it was clear that none of the subjects would choose to use this single screen version of FilmPlane for typical clinical work. Since starting this pilot experiment, FilmPlane has been modified to operate with any number of screens. Dynamic intensity windowing with 12 bit images and an 8 bit framebuffer seems viable, and the basic interaction implemented with FilmPlane2.2 is effective, through it needs additional developmental work. A workstation allowing true 12-bit intensity windowing is clearly superior, but given the cost advantage of 8-bit framebuffers, it is encouraging to see indications that commodity priced 8-bit units are viable. Based on the results of this pilot study, we plan to conduct a similar large scale study evaluating a multiple-screen version of FilmPlane with cases containing multiple examinations. 4. REFERENCES Beard, DV, Parrish, D, Stevenson, D, A Cost Analysis of Film Image Management and Four PACS systemsbased on Four Network Protocols, Journal ofdigital Imaging, May 1990 (A). Beard DV, Designing a Radiology Workstation: A ocus on Navigation During the Interpretation Task, Journal ofdigitallmaging Aug 1990 (B). Foley WD, Jacobson, DR, Taylor AJ, et. al, Display of CT Studies on a Two-Screen Electronic Workstation Versus a Film Panel Alternator: Sensitivity and Efficiency Among Radiologists, Radiology, 174, , March Johnston RE, Yankaskas BC, Perry JR, Pizer SM, Delany DJ, Parker LA, Agreement Experiments: A Method for Quantitatively Testing New Medical Image Display Approaches, SPifi vol Medical Imaging IV, Pizer, SM, and Beard, DV, "Medical Image Workstations: State of Science & Technology". Journal ofdigitallmaging, Noy (4) Walker J and Beard DV FilmPlane2: Design and Implementation, SPIE medical Image ' Zimmerman JB, Pizer SM, Staab E, Perry J, McCartney W, and Brenton B, "An Evaluation of the Effectiveness of Adaptive Histogram Equalization for Contrast Enhancement," IEEE Transactions on Medical Imaging, 7(4): , / SPIE Vol Medical Imaging V. PACS Design and Evaluation (1991)

Effective Presentation of Medical Images

Effective Presentation of Medical Images Effective Presentation of Medical Images September, 1987 Technical Report 87-026 Stephen M. Pizer, R. Eugene Johnston, Diane Rogers, David Beard The University of North Carolina at Chapel Hill Department

More information

Development of a Prototype Electronic Alternator for DIN/PACS Environment and its Evaluation. H. S. Choi1, H. W. Park1, D. R. Haynor2, and Y.

Development of a Prototype Electronic Alternator for DIN/PACS Environment and its Evaluation. H. S. Choi1, H. W. Park1, D. R. Haynor2, and Y. Development of a Prototype Electronic Alternator for DIN/PACS Environment and its Evaluation H. S. Choi1, H. W. Park1, D. R. Haynor2, and Y. Kim' 1 Department of Electrical Engineering 2Department of Radiology

More information

PACS Fundamentals. By: Eng. Valentino T. Mvanga Ministry of Health and Social Welfare Tanzania

PACS Fundamentals. By: Eng. Valentino T. Mvanga Ministry of Health and Social Welfare Tanzania PACS Fundamentals By: Eng. Valentino T. Mvanga Ministry of Health and Social Welfare Tanzania 1 Learning Goals To Understand the importance of PACS To Understand PACS infrastructure requirement Introduction

More information

Discover the new Prestige and experience 3D/4D imaging beyond your imagination.

Discover the new Prestige and experience 3D/4D imaging beyond your imagination. 3D/4D Beyond Imagination The Prestige ultrasound imaging system represents the pinnacle of more than a decade of technological advancement in 3D/4D ultrasound imaging at MEDISON. Inheriting a tradition

More information

FCR XL-2 and FCR XC-2. High-quality digital x-ray that's perfect for your private practice.

FCR XL-2 and FCR XC-2. High-quality digital x-ray that's perfect for your private practice. F U J I F I L M D I G I T A L X - R A Y FCR XL-2 and FCR XC-2. High-quality digital x-ray that's perfect for your private practice. So small, yet so powerful. With a compact footprint of less than 2.5

More information

MUSICA Nerve Center. Artificial Intelligence. Intelligent tools for your Digital Radiography workflow. Fluoroscopy. Workflow Optimization

MUSICA Nerve Center. Artificial Intelligence. Intelligent tools for your Digital Radiography workflow. Fluoroscopy. Workflow Optimization Image Quality Bariatric Abdomen Pediatric Imaging Diagnostic Confidence Fluoroscopy Neonatal Imaging Scatter Suppression Dental Full Leg Full Spine Exposure Control Index Artificial Intelligence General

More information

IHE Radiology Technical Framework Supplement. Stereotactic Mammography Image (SMI) Trial Implementation

IHE Radiology Technical Framework Supplement. Stereotactic Mammography Image (SMI) Trial Implementation Integrating the Healthcare Enterprise 5 IHE Radiology Technical Framework Supplement 10 Stereotactic Mammography Image (SMI) 15 Trial Implementation 20 25 Date: June 11, 2013 Author: IHE Radiology Technical

More information

Incorporating novel image processing methods in a hospital-wide PACS

Incorporating novel image processing methods in a hospital-wide PACS International Congress Series 1281 (2005) 1016 1021 www.ics-elsevier.com Incorporating novel image processing methods in a hospital-wide PACS Erwin Bellon a, T, Michel Feron a, Paul Neyens a, Klaas Peeters

More information

radiography detector

radiography detector Clinical evaluation of a full field digital projection radiography detector Gary S. Shaber'1, Denny L. Leeb, Jeffrey Belib, Gregory Poweii1', Andrew D.A. Maidment'1 a Thomas Jefferson University Hospital,

More information

A MULTIPROCESSOR ADAPTIVE HISTOGRAM EQUALIZATION MACHINE

A MULTIPROCESSOR ADAPTIVE HISTOGRAM EQUALIZATION MACHINE A MULTIPROCESSOR ADAPTIVE HISTOGRAM EQUALIZATION MACHINE Technical Report 86-002 Jobn D. Austin and Stepben M. Pizer -r-~ /i ~I I I\~ The University of North Carolina at Chapel Hill Department of Computer

More information

VIRTUAL ASSISTIVE ROBOTS FOR PLAY, LEARNING, AND COGNITIVE DEVELOPMENT

VIRTUAL ASSISTIVE ROBOTS FOR PLAY, LEARNING, AND COGNITIVE DEVELOPMENT 3-59 Corbett Hall University of Alberta Edmonton, AB T6G 2G4 Ph: (780) 492-5422 Fx: (780) 492-1696 Email: atlab@ualberta.ca VIRTUAL ASSISTIVE ROBOTS FOR PLAY, LEARNING, AND COGNITIVE DEVELOPMENT Mengliao

More information

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT)

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT) Radionuclide Imaging MII 3073 Single Photon Emission Computed Tomography (SPECT) Single Photon Emission Computed Tomography (SPECT) The successful application of computer algorithms to x-ray imaging in

More information

Virtual I.V. System overview. Directions for Use.

Virtual I.V. System overview. Directions for Use. System overview 37 System Overview Virtual I.V. 6.1 Software Overview The Virtual I.V. Self-Directed Learning System software consists of two distinct parts: (1) The basic menus screens, which present

More information

Microsoft Scrolling Strip Prototype: Technical Description

Microsoft Scrolling Strip Prototype: Technical Description Microsoft Scrolling Strip Prototype: Technical Description Primary features implemented in prototype Ken Hinckley 7/24/00 We have done at least some preliminary usability testing on all of the features

More information

COMPUTED TOMOGRAPHY 1

COMPUTED TOMOGRAPHY 1 COMPUTED TOMOGRAPHY 1 Why CT? Conventional X ray picture of a chest 2 Introduction Why CT? In a normal X-ray picture, most soft tissue doesn't show up clearly. To focus in on organs, or to examine the

More information

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893 Digital Radiography D. J. Hall, Ph.D. x20893 djhall@ucsd.edu Background Common Digital Modalities Digital Chest Radiograph - 4096 x 4096 x 12 bit CT - 512 x 512 x 12 bit SPECT - 128 x 128 x 8 bit MRI -

More information

2D, 3D CT Intervention, and CT Fluoroscopy

2D, 3D CT Intervention, and CT Fluoroscopy 2D, 3D CT Intervention, and CT Fluoroscopy SOMATOM Definition, Definition AS, Definition Flash Answers for life. Siemens CT Vision Siemens CT Vision The justification for the existence of the entire medical

More information

Ludlum Medical Physics

Ludlum Medical Physics Ludlum Medical Physics Medical Imaging Radiology QA Test Tools NEW LUDLUM PRODUCT LINE Medical Physics Products Medical Physics Products What are they? Products used to measure radiation output and to

More information

Planmeca Romexis. quick guide. Viewer EN _2

Planmeca Romexis. quick guide. Viewer EN _2 Planmeca Romexis Viewer quick guide EN 10029550_2 TABLE OF CONTENTS 1 START-UP OF PLANMECA ROMEXIS VIEWER...1 1.1 Selecting the interface language... 1 1.2 Selecting images...1 1.3 Starting the Planmeca

More information

GE Healthcare. Senographe 2000D Full-field digital mammography system

GE Healthcare. Senographe 2000D Full-field digital mammography system GE Healthcare Senographe 2000D Full-field digital mammography system Digital has arrived. The Senographe 2000D Full-Field Digital Mammography (FFDM) system gives you a unique competitive advantage. That

More information

(12) Patent Application Publication (10) Pub. No.: US 2007/ A1

(12) Patent Application Publication (10) Pub. No.: US 2007/ A1 (19) United States US 200701 18100A1 (12) Patent Application Publication (10) Pub. No.: US 2007/0118100 A1 Mahesh et al. (43) Pub. Date: (54) SYSTEM AND METHOD FOR IMPROVED ABLATION OF TUMIORS (75) Inventors:

More information

SIGNA Explorer Lift revives our MR

SIGNA Explorer Lift revives our MR Seiji Shiotani, MD, PhD Seirei Fuji Hospital in Fuji City, Shizuoka, Japan Masayoshi Sugimura Seirei Fuji Hospital in Fuji City, Shizuoka, Japan SIGN Explorer Lift revives our MR The clinical usefulness

More information

IMPAX 6 DISPLAY TOOL LIST

IMPAX 6 DISPLAY TOOL LIST IMPAX 6 DISPLAY TOOL LIST IMPAX 6.0 TOOLS INDEX A Advance by Image Allows you to scroll from one image or frame to the next Advance by Page Pages through images in a large series, one screen at a time

More information

While digital techniques have the potential to reduce patient doses, they also have the potential to significantly increase them.

While digital techniques have the potential to reduce patient doses, they also have the potential to significantly increase them. In press 2004 1 2 Guest Editorial (F. Mettler, H. Ringertz and E. Vano) Guest Editorial (F. Mettler, H. Ringertz and E. Vano) Digital radiology An appropriate analogy that is easy for most people to understand

More information

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS RADT 3463 - COMPUTERIZED IMAGING Section I: Chapter 2 RADT 3463 Computerized Imaging 1 SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS RADT 3463 COMPUTERIZED IMAGING Section I: Chapter 2 RADT

More information

BodyViz fact sheet. BodyViz 2321 North Loop Drive, Suite 110 Ames, IA x555 www. bodyviz.com

BodyViz fact sheet. BodyViz 2321 North Loop Drive, Suite 110 Ames, IA x555 www. bodyviz.com BodyViz fact sheet BodyViz, the company, was established in 2007 at the Iowa State University Research Park in Ames, Iowa. It was created by ISU s Virtual Reality Applications Center Director James Oliver,

More information

User Manual Veterinary

User Manual Veterinary Veterinary Acquisition and diagnostic software Doc No.: Rev 1.0.1 Aug 2013 Part No.: CR-FPM-04-022-EN-S 3DISC, FireCR, Quantor and the 3D Cube are trademarks of 3D Imaging & Simulations Corp, South Korea,

More information

VISUOMOTOR PROGRAM DESCRIPTION AND OVERVIEW

VISUOMOTOR PROGRAM DESCRIPTION AND OVERVIEW VISUOMOTOR PROGRAM DESCRIPTION AND OVERVIEW Overview System hardware consists of a touchscreen display (46-65 ), extremely portable stand and an Intel NUC running Windows 8. The display can be rotated,

More information

ImagesPlus Basic Interface Operation

ImagesPlus Basic Interface Operation ImagesPlus Basic Interface Operation The basic interface operation menu options are located on the File, View, Open Images, Open Operators, and Help main menus. File Menu New The New command creates a

More information

DIGITAL MOBILE CXR THE NIGERIA FIELD EXPERIENCE NIGERIA TEAM UN CC, ADDIS ABABA 5-8, 2010

DIGITAL MOBILE CXR THE NIGERIA FIELD EXPERIENCE NIGERIA TEAM UN CC, ADDIS ABABA 5-8, 2010 DIGITAL MOBILE CXR THE NIGERIA FIELD EXPERIENCE NIGERIA TEAM PRESENTATION @ UN CC, ADDIS ABABA 5-8, 2010 Specific objectives 1. To determine the prevalence of smear positive pulmonary TB among the eligible

More information

PERFORMANCE IN A HAPTIC ENVIRONMENT ABSTRACT

PERFORMANCE IN A HAPTIC ENVIRONMENT ABSTRACT PERFORMANCE IN A HAPTIC ENVIRONMENT Michael V. Doran,William Owen, and Brian Holbert University of South Alabama School of Computer and Information Sciences Mobile, Alabama 36688 (334) 460-6390 doran@cis.usouthal.edu,

More information

DR _ solutions. We understand that customers don t need just products, they want. solutions

DR _ solutions. We understand that customers don t need just products, they want. solutions DR _ solutions We understand that customers don t need just products, they want solutions index company profile 1974-2005 2006-2007 - 2008 ITALRAY Srl was founded in 1974 as the production branch of Marzocchi

More information

Phone Interview Tips (Transcript)

Phone Interview Tips (Transcript) Phone Interview Tips (Transcript) This document is a transcript of the Phone Interview Tips video that can be found here: https://www.jobinterviewtools.com/phone-interview-tips/ https://youtu.be/wdbuzcjweps

More information

Improving Depth Perception in Medical AR

Improving Depth Perception in Medical AR Improving Depth Perception in Medical AR A Virtual Vision Panel to the Inside of the Patient Christoph Bichlmeier 1, Tobias Sielhorst 1, Sandro M. Heining 2, Nassir Navab 1 1 Chair for Computer Aided Medical

More information

Clinical Experience Using the Open Bore Multislice CT System Supria (16 slice CT) MEDIX VOL. 61 P.8 P.11

Clinical Experience Using the Open Bore Multislice CT System Supria (16 slice CT) MEDIX VOL. 61 P.8 P.11 Clinical Experience Using the Open Bore Multislice CT System Supria (16 slice CT) Hiroki Kadoya Yukiko Kitagawa MEDIX VOL. 61 P.8 P.11 Clinical Experience Using the Open Bore Multislice CT System Supria

More information

EYE MOVEMENT STRATEGIES IN NAVIGATIONAL TASKS Austin Ducworth, Melissa Falzetta, Lindsay Hyma, Katie Kimble & James Michalak Group 1

EYE MOVEMENT STRATEGIES IN NAVIGATIONAL TASKS Austin Ducworth, Melissa Falzetta, Lindsay Hyma, Katie Kimble & James Michalak Group 1 EYE MOVEMENT STRATEGIES IN NAVIGATIONAL TASKS Austin Ducworth, Melissa Falzetta, Lindsay Hyma, Katie Kimble & James Michalak Group 1 Abstract Navigation is an essential part of many military and civilian

More information

Evaluating Touch Gestures for Scrolling on Notebook Computers

Evaluating Touch Gestures for Scrolling on Notebook Computers Evaluating Touch Gestures for Scrolling on Notebook Computers Kevin Arthur Synaptics, Inc. 3120 Scott Blvd. Santa Clara, CA 95054 USA karthur@synaptics.com Nada Matic Synaptics, Inc. 3120 Scott Blvd. Santa

More information

Interacting with Image Sequences: Detail-in-Context and Thumbnails

Interacting with Image Sequences: Detail-in-Context and Thumbnails Interacting with Image Sequences: Detail-in-Context and Thumbnails ABSTRACT An image sequence is a series of interrelated images. To enable navigation of large image sequences, many current software packages

More information

Model Based Iterative Reconstructions represent a paradigm shift - Imaging with almost no noise

Model Based Iterative Reconstructions represent a paradigm shift - Imaging with almost no noise Model Based Iterative Reconstructions represent a paradigm shift - Imaging with almost no noise Jonas Rydberg, M.D. Professor of Radiology Indiana University School of Medicine Indianapolis, Indiana Medical

More information

Current technology in digital image production (CR/DR and other modalities) Jaroonroj Wongnil 25 Mar 2016

Current technology in digital image production (CR/DR and other modalities) Jaroonroj Wongnil 25 Mar 2016 Current technology in digital image production (CR/DR and other modalities) Jaroonroj Wongnil 25 Mar 2016 Current technology in digital image production (CR/DR and other modalities) 2/ Overview Digital

More information

Intuitive Gestures on Multi-touch Displays for Reading Radiological Images

Intuitive Gestures on Multi-touch Displays for Reading Radiological Images Intuitive Gestures on Multi-touch Displays for Reading Radiological Images Susanne Bay 2, Philipp Brauner 1, Thomas Gossler 2, and Martina Ziefle 1 1 Human-Computer Interaction Center, RWTH Aachen University,

More information

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II APPROVED 12/O2/2011 EFFECTIVE SPRING 2013-14 Prefix & Number RAD 150 Course Title: Radiologic Exposure Technique II & Lab Purpose of this submission: New Change/Updated

More information

MRI imaging in neuroscience Dr. Thom Oostendorp Lab class: 2 hrs

MRI imaging in neuroscience Dr. Thom Oostendorp Lab class: 2 hrs MRI imaging in neuroscience Dr. Thom Oostendorp Lab class: 2 hrs 1 Introduction In tomographic imaging techniques, such as MRI, a certain tissue property within a slice is imaged. For each voxel (volume

More information

Comparison of Haptic and Non-Speech Audio Feedback

Comparison of Haptic and Non-Speech Audio Feedback Comparison of Haptic and Non-Speech Audio Feedback Cagatay Goncu 1 and Kim Marriott 1 Monash University, Mebourne, Australia, cagatay.goncu@monash.edu, kim.marriott@monash.edu Abstract. We report a usability

More information

Further Customization of Dot Engines: AutoCoverage

Further Customization of Dot Engines: AutoCoverage Further Customization of Dot Engines: AutoCoverage Bart Schraa, MSc., Senior MR Application Specialist Siemens Canada Limited, Oakville, ON, Canada Introduction In 2009 Dot engines introduced a very powerful

More information

NAVIGATIONAL CONTROL EFFECT ON REPRESENTING VIRTUAL ENVIRONMENTS

NAVIGATIONAL CONTROL EFFECT ON REPRESENTING VIRTUAL ENVIRONMENTS NAVIGATIONAL CONTROL EFFECT ON REPRESENTING VIRTUAL ENVIRONMENTS Xianjun Sam Zheng, George W. McConkie, and Benjamin Schaeffer Beckman Institute, University of Illinois at Urbana Champaign This present

More information

A TELE-INSTRUCTION SYSTEM FOR ULTRASOUND PROBE OPERATION BASED ON SHARED AR TECHNOLOGY

A TELE-INSTRUCTION SYSTEM FOR ULTRASOUND PROBE OPERATION BASED ON SHARED AR TECHNOLOGY A TELE-INSTRUCTION SYSTEM FOR ULTRASOUND PROBE OPERATION BASED ON SHARED AR TECHNOLOGY T. Suenaga 1, M. Nambu 1, T. Kuroda 2, O. Oshiro 2, T. Tamura 1, K. Chihara 2 1 National Institute for Longevity Sciences,

More information

Medical Images Analysis and Processing

Medical Images Analysis and Processing Medical Images Analysis and Processing - 25642 Emad Course Introduction Course Information: Type: Graduated Credits: 3 Prerequisites: Digital Image Processing Course Introduction Reference(s): Insight

More information

A Study On Preprocessing A Mammogram Image Using Adaptive Median Filter

A Study On Preprocessing A Mammogram Image Using Adaptive Median Filter A Study On Preprocessing A Mammogram Image Using Adaptive Median Filter Dr.K.Meenakshi Sundaram 1, D.Sasikala 2, P.Aarthi Rani 3 Associate Professor, Department of Computer Science, Erode Arts and Science

More information

Maximizing clinical outcomes

Maximizing clinical outcomes Maximizing clinical outcomes Digital Tomosynthesis Dual Energy Subtraction Automated Long Length Imaging Improved image quality at a low dose Xray Xray Patented ISS capture technology promotes high sensitivity

More information

DELWORKS DR MEDICAL. take the next step

DELWORKS DR MEDICAL. take the next step DELWORKS DR MEDICAL take the next step DELWORKS MEDICAL DR If you are thinking of taking the next step to digital radiography, consider a DelWorks Medical DR Retrofit Package, the easy and affordable way

More information

Titolo presentazione sottotitolo

Titolo presentazione sottotitolo Integration of a Virtual Reality Environment for Percutaneous Renal Puncture in the Routine Clinical Practice of a Tertiary Department of Interventional Urology: A Feasibility Study Titolo presentazione

More information

Please also note that this is an annual survey, so many of these questions will be familiar to you if you completed a survey last year.

Please also note that this is an annual survey, so many of these questions will be familiar to you if you completed a survey last year. Welcome to the 2016 National MLP Survey Thank you for agreeing to participate in this survey. You are receiving this survey because you have indicated to the National Center for Medical-Legal Partnership

More information

Image Optimization: The Sonographer s Responsibility. Prepared by Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT

Image Optimization: The Sonographer s Responsibility. Prepared by Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT Image Optimization: The Sonographer s Responsibility Prepared by Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT Image Optimization: The Sonographer s Responsibility Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT Disclosure

More information

Exercise 4-1 Image Exploration

Exercise 4-1 Image Exploration Exercise 4-1 Image Exploration With this exercise, we begin an extensive exploration of remotely sensed imagery and image processing techniques. Because remotely sensed imagery is a common source of data

More information

Digital radiography (DR) post processing techniques for pediatric radiology

Digital radiography (DR) post processing techniques for pediatric radiology Digital radiography (DR) post processing techniques for pediatric radiology St Jude Children s Research Hospital Samuel Brady, MS PhD DABR samuel.brady@stjude.org Purpose Review common issues and solutions

More information

Multi-Access Biplane Lab

Multi-Access Biplane Lab Multi-Access Biplane Lab Advanced technolo gies deliver optimized biplane imaging Designed in concert with leading physicians, the Infinix VF-i/BP provides advanced, versatile patient access to meet the

More information

Interacting with Image Sequences: Detail-in-Context and Thumbnails

Interacting with Image Sequences: Detail-in-Context and Thumbnails Interacting with Image Sequences: Detail-in-Context and Thumbnails Oliver Kuederle, Kori M. Inkpen, M. Stella Atkins {okuederl,inkpen,stella}@cs.sfu.ca School of Computing Science Simon Fraser University

More information

Medical Imaging Displays: Psychophysics and Quality Assurance: Psychophysics and the Human Visual System

Medical Imaging Displays: Psychophysics and Quality Assurance: Psychophysics and the Human Visual System Medical Imaging Displays: Psychophysics and Quality Assurance: Psychophysics and the Human Visual System Rationale Display options present significant challenge - which use, under what circumstances, how

More information

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments.

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments. Choose the FCR system that best fits your practice. The FCR XL-2. Perfect for higher-volume environments. It can process up to 94 images per hour yet it fits right into small exam rooms or offices where

More information

The Effect of Intensity Windowing on the Detection of Simulated Masses Embedded in Dense Portions of Digitized Mammograms in a Laboratory Setting

The Effect of Intensity Windowing on the Detection of Simulated Masses Embedded in Dense Portions of Digitized Mammograms in a Laboratory Setting The Effect of Intensity Windowing on the Detection of Simulated Masses Embedded in Dense Portions of Digitized Mammograms in a Laboratory Setting Etta D. Pisano, MD* # Jayanthi Chandramouli` Bradley M.

More information

Quantum Medical Imaging

Quantum Medical Imaging Quantum Medical Imaging Pioneering technology from the premiere innovator in veterinary imaging Corporate Overview Quantum Medical Imaging is a highly innovative company which designs and manufactures

More information

Anatomy in Action. OpenSIUC. Southern Illinois University Carbondale. Erik Steven Herman

Anatomy in Action. OpenSIUC. Southern Illinois University Carbondale. Erik Steven Herman Southern Illinois University Carbondale OpenSIUC Honors Theses University Honors Program 5-1989 Anatomy in Action Erik Steven Herman Follow this and additional works at: http://opensiuc.lib.siu.edu/uhp_theses

More information

The Versatile and Powerful ACLxy. ACLxy

The Versatile and Powerful ACLxy. ACLxy The Versatile and Powerful ACLxy ACLxy Rolling into a Clinic, Imaging Center and Hospital Near You! COMPUTED RADIOGRAPHY (CR) IS RAPIDLY THE BEGINNING. THE OREX CR SOLUTION DRA- BECOMING A DRIVING FORCE

More information

COCIR SELF-REGULATORY INITIATIVE FOR MEDICAL IMAGING EQUIPMENT COMPUTED TOMOGRAPHY MEASUREMENT OF ENERGY CONSUMPTION

COCIR SELF-REGULATORY INITIATIVE FOR MEDICAL IMAGING EQUIPMENT COMPUTED TOMOGRAPHY MEASUREMENT OF ENERGY CONSUMPTION COCIR SELF-REGULATORY INITIATIVE FOR MEDICAL IMAGING EQUIPMENT COMPUTED TOMOGRAPHY MEASUREMENT OF ENERGY CONSUMPTION Revision: 1 Date: June 2015 Approved: June 2015 TABLE OF CONTENT 1. INTRODUCTION...

More information

The Camera Club. David Champion January 2011

The Camera Club. David Champion January 2011 The Camera Club B&W Negative Proccesing After Scanning. David Champion January 2011 That s how to scan a negative, now I will explain how to process the image using Photoshop CS5. To achieve a good scan

More information

The Trend of Medical Image Work Station

The Trend of Medical Image Work Station The Trend of Medical Image Work Station Abstract Image Work Station has rapidly improved its efficiency and its quality along the development of biomedical engineering. The quality improvement of image

More information

Zeiss LSM 780 Protocol

Zeiss LSM 780 Protocol Zeiss LSM 780 Protocol 1) System Startup F Please note the sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for unused time.

More information

A Practical Overview of the Clinical and Operational Impact of Computed Radiography(CR) Implementations. Shirley Weddle, RT(R)(M), CIIP, BBA

A Practical Overview of the Clinical and Operational Impact of Computed Radiography(CR) Implementations. Shirley Weddle, RT(R)(M), CIIP, BBA A Practical Overview of the Clinical and Operational Impact of Computed Radiography(CR) Implementations Shirley Weddle, RT(R)(M), CIIP, BBA OBJECTIVES Define Computed Radiography (CR) Discuss CR vendor

More information

Modeling Your Motion When Walking

Modeling Your Motion When Walking Before you begin your lab activities today, your instructor will review the following: Lab sign-in sheet Lab partners (you will probably work with the same group as during lab #01) Comments on lab #01

More information

Peripheral imaging with electronic memory unit

Peripheral imaging with electronic memory unit Rochester Institute of Technology RIT Scholar Works Articles 1997 Peripheral imaging with electronic memory unit Andrew Davidhazy Follow this and additional works at: http://scholarworks.rit.edu/article

More information

CHUCK E. CHEESE S MATCH GAME

CHUCK E. CHEESE S MATCH GAME CHUCK E. CHEESE S MATCH GAME PLAYING THE GAME Chuck E. Cheese s Match Game is a memory match game for one player. The player is shown nine curtains which reveal five different characters: Chuck E. Cheese,

More information

Multimodal Co-registration Using the Quantum GX, G8 PET/CT and IVIS Spectrum Imaging Systems

Multimodal Co-registration Using the Quantum GX, G8 PET/CT and IVIS Spectrum Imaging Systems TECHNICAL NOTE Preclinical In Vivo Imaging Authors: Jen-Chieh Tseng, Ph.D. Jeffrey D. Peterson, Ph.D. PerkinElmer, Inc. Hopkinton, MA Multimodal Co-registration Using the Quantum GX, G8 PET/CT and IVIS

More information

CT Data Storage Reduction by Means of Compressing Projection Data Instead of Images: Feasibility Study 1

CT Data Storage Reduction by Means of Compressing Projection Data Instead of Images: Feasibility Study 1 Kyongtae T. Bae, MD, PhD Bruce R. Whiting, PhD Index terms: Computed tomography (CT), image display and recording Computed tomography (CT), image processing Computed tomography (CT), technology Data compression

More information

Wound Analyzer TiVi103 User Manual. User Manual 1.1 Version 1.1 October 2012 PIONEERS IN TISSUE VIABILITY IMAGING

Wound Analyzer TiVi103 User Manual. User Manual 1.1 Version 1.1 October 2012 PIONEERS IN TISSUE VIABILITY IMAGING Wound Analyzer TiVi103 User Manual User Manual 1.1 Version 1.1 October 2012 PIONEERS IN TISSUE VIABILITY IMAGING Dear Valued Customer! Welcome to the WheelsBridge TiVi103 Wound Analyzer system intended

More information

A Kinect-based 3D hand-gesture interface for 3D databases

A Kinect-based 3D hand-gesture interface for 3D databases A Kinect-based 3D hand-gesture interface for 3D databases Abstract. The use of natural interfaces improves significantly aspects related to human-computer interaction and consequently the productivity

More information

EDGE-AFFECTED CONTEXT FOR ADAPTIVE CONTRAST ENHANCEMENT

EDGE-AFFECTED CONTEXT FOR ADAPTIVE CONTRAST ENHANCEMENT EDGE-AFFECTED CONTEXT FOR ADAPTIVE CONTRAST ENHANCEMENT R Cromartie! and S M Pizerl,2 1 Department of Computer Science 2Departments of Radiology and Radiation Oncology The University of North Carolina

More information

Quantitation of clinical feedback on image quality differences between two CT scanner models

Quantitation of clinical feedback on image quality differences between two CT scanner models Received: 4 August 2016 Revised: 4 November 2016 Accepted: 12 December 2016 DOI: 10.1002/acm2.12050 MEDICAL IMAGING Quantitation of clinical feedback on image quality differences between two CT scanner

More information

Infrared Screening. with TotalVision anatomy software

Infrared Screening. with TotalVision anatomy software Infrared Screening with TotalVision anatomy software Unlimited possibilities with our high-quality infrared screening systems Energetic Health Systems leads the fi eld in infrared screening and is the

More information

BRINGING DEEP LEARNING TO ENTERPRISE IMAGING CLINICAL PRACTICE

BRINGING DEEP LEARNING TO ENTERPRISE IMAGING CLINICAL PRACTICE BRINGING DEEP LEARNING TO ENTERPRISE IMAGING CLINICAL PRACTICE Esteban Rubens Global Enterprise Imaging Principal Pure Storage @pureesteban AI IN HEALTHCARE What is Artificial Intelligence (AI)? How is

More information

Physician Experience With Viewing Digital Radiographs in an Intensive Care Unit Environment

Physician Experience With Viewing Digital Radiographs in an Intensive Care Unit Environment Physician Experience With Viewing Digital Radiographs in an Intensive Care Unit Environment Louis M. Humphrey, Kevin Fitzpatrick, Susan S. Paine, and Carl E. Ravin After several years of continuous operation,

More information

Laboratory 1: Motion in One Dimension

Laboratory 1: Motion in One Dimension Phys 131L Spring 2018 Laboratory 1: Motion in One Dimension Classical physics describes the motion of objects with the fundamental goal of tracking the position of an object as time passes. The simplest

More information

Stereoscopic Augmented Reality System for Computer Assisted Surgery

Stereoscopic Augmented Reality System for Computer Assisted Surgery Marc Liévin and Erwin Keeve Research center c a e s a r, Center of Advanced European Studies and Research, Surgical Simulation and Navigation Group, Friedensplatz 16, 53111 Bonn, Germany. A first architecture

More information

Digital Image Management: the Basics

Digital Image Management: the Basics Digital Image Management: the Basics Napapong Pongnapang, Ph.D. Department of Radiological Technology Faculty of Medical Technology Mahidol University Outline From screen/film to digital radiography PACS/Tele

More information

DirectView CR 850 System. A fast, premium single-cassette CR system

DirectView CR 850 System. A fast, premium single-cassette CR system A fast, premium single-cassette CR system DirectView CR 850 System DirectView CR 850 System Optional Accessories V3 Software/Feature Package Image preparation entry features include a configurable text

More information

An Activity in Computed Tomography

An Activity in Computed Tomography Pre-lab Discussion An Activity in Computed Tomography X-rays X-rays are high energy electromagnetic radiation with wavelengths smaller than those in the visible spectrum (0.01-10nm and 4000-800nm respectively).

More information

The Script of ZST + Presentation. MIS Upstream Marketing Team [ 日期 ]

The Script of ZST + Presentation. MIS Upstream Marketing Team [ 日期 ] 1 The Script of ZST + Presentation MIS Upstream Marketing Team [ 日期 ] 1 The Script of ZST + Presentation Since Mindray was founded to develop ultrasound business, core technology has always been the engine

More information

QC by the MPE in Belgium

QC by the MPE in Belgium Acceptance testing of state-of-the-art CT scanners using a new national protocol: first experience on a large number of scanners of different make and model the working group Radiology of the Belgian Hospital

More information

Surface Analyzer TiVi95 User Manual. User Manual 3.1 Version 3.1 January 2012 PIONEERS IN TISSUE VIABILITY IMAGING

Surface Analyzer TiVi95 User Manual. User Manual 3.1 Version 3.1 January 2012 PIONEERS IN TISSUE VIABILITY IMAGING Surface Analyzer TiVi95 User Manual User Manual 3.1 Version 3.1 January 2012 PIONEERS IN TISSUE VIABILITY IMAGING Dear Valued Customer! Welcome to the WheelsBridge TiVi95 Skin Surface Analyzer system intended

More information

ScanArray Overview. Principle of Operation. Instrument Components

ScanArray Overview. Principle of Operation. Instrument Components ScanArray Overview The GSI Lumonics ScanArrayÒ Microarray Analysis System is a scanning laser confocal fluorescence microscope that is used to determine the fluorescence intensity of a two-dimensional

More information

Visual Interpretation of Hand Gestures as a Practical Interface Modality

Visual Interpretation of Hand Gestures as a Practical Interface Modality Visual Interpretation of Hand Gestures as a Practical Interface Modality Frederik C. M. Kjeldsen Submitted in partial fulfillment of the requirements for the degree of Doctor of Philosophy in the Graduate

More information

K ODAK D IRECTV IEW CR 850 SYSTEM

K ODAK D IRECTV IEW CR 850 SYSTEM CR 850 SYSTEM The fastest single-cassette CR system HEALTH IMAGING A BETTER V IEW OF L IFE. CR 850 SYSTEM THE FASTEST SINGLE-CASSETTE CR SYSTEM Boost productivity with the quicker, easy-to-use Kodak DirectView

More information

Zeiss LSM 880 Protocol

Zeiss LSM 880 Protocol Zeiss LSM 880 Protocol 1) System Startup Please note put sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for unused time.

More information

AUDIOSCOPE OPERATING MANUAL

AUDIOSCOPE OPERATING MANUAL AUDIOSCOPE OPERATING MANUAL Online Electronics Audioscope software plots the amplitude of audio signals against time allowing visual monitoring and interpretation of the audio signals generated by Acoustic

More information

Nuclear Associates

Nuclear Associates Nuclear Associates 07-647 R/F QC Phantom Operators Manual March 2005 Manual No. 07-647-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. All product names are trademarks of their respective companies

More information

Your Partner Holds a Strong Balanced Hand Your Hand Is Balanced

Your Partner Holds a Strong Balanced Hand Your Hand Is Balanced Bid Your Slams! There is both an art and a science to accurate slam bidding. Modern bidding conventions have improved the science of slam bidding, but the art is something that develops with intelligent

More information

Robotic Systems Challenge 2013

Robotic Systems Challenge 2013 Robotic Systems Challenge 2013 An engineering challenge for students in grades 6 12 April 27, 2013 Charles Commons Conference Center JHU Homewood Campus Sponsored by: Johns Hopkins University Laboratory

More information

Eleva Workspot 1.x - Training. Advanced User Functions. State: April 2007

Eleva Workspot 1.x - Training. Advanced User Functions. State: April 2007 Eleva Workspot 1.x - Training Advanced User Functions State: April 2007 Purpose of this Presentation General Get an overview about all "" functions in Eleva Workspot 1.x These are available in the System

More information

HUMAN COMPUTER INTERFACE

HUMAN COMPUTER INTERFACE HUMAN COMPUTER INTERFACE TARUNIM SHARMA Department of Computer Science Maharaja Surajmal Institute C-4, Janakpuri, New Delhi, India ABSTRACT-- The intention of this paper is to provide an overview on the

More information

Softcopy Display Requirements for Digital Mammography

Softcopy Display Requirements for Digital Mammography Softcopy Display Requirements for Digital Mammography Bradley M. Hemminger School of Information and Library Science, University of North Carolina at Chapel Hill ABSTRACT Purpose One of the advantages

More information