1 RENOVATIONS TO VARIOUS MONROE COUNTY SCHOOLS MONROEVILLE, AL MONROE COUNTY BOARD OF EDUCATION ABC PROJECT NO ADDENDUM NUMBER 4 Thursday, May 8, 2014 PROJECT: RENOVATIONS TO VARIOUS MONROE COUNTY SCHOOLS FOR THE MONROE COUNTY BOARD OF EDUCATION LOCATED IN MONROEVILLE, ALABAMA ABC PROJECT NO GMC PROJECT NO. AMGM AD4-1 GENERAL: A. The following revisions and/or additions to the Drawings and Project Manual are hereby made a part of same, and shall be incorporated in the Work of the Contract the same as if originally included in the Bid and Construction Documents. B. Bidders shall acknowledge receipt of this Addendum in writing, as provided on the Proposal Form. C. When a revision and/or addition is called for to the Drawings or Project Manual, they shall be fully coordinated with and carried through all applicable Drawings and portions of the Project Manual, including in part, all related Civil, Landscaping, Architectural, Structural, Plumbing, Mechanical, Electrical, and other Documents. AD4-2 PROJECT MANUAL AND SPECIFICATIONS: A. Refer to Advertisement for Bids and Addendum No Change Bid Date only from Thursday, May 8, 2014, to read Wednesday, May 14, B. Refer to Specification Section Metal Lockers. Part 2 Products 2.1 Manufacturers Revise locks to provide a master key and 10 control keys for the tumble locks for security box and foot locker. AD4-3 DRAWINGS: A. Refer to Drawing A3.01a detail 3. Change dimension of pockets from 2-4 to 2-7. Dimension between pipe rails should be 3½. B. Refer to Drawing A1.01c Floor Plan Showers C101 and C102. Delete all work associated with shower rooms. C. Refer to Drawing A1.01d Floor Plans. Note ambulatory stalls doors to be a minimum of 32 wide in the 90 open position. D. Refer to attached letter from Borden Morris Garner and drawings ADE.1, ADE.2, ADE.3, ADE.4, ADM.1, ADP.1 and ADP.2. GOODWYN, MILLS & CAWOOD, INC. ADDENDUM NO. 4 GMC PROJECT NO. AMGM of 2
2 RENOVATIONS TO VARIOUS MONROE COUNTY SCHOOLS MONROEVILLE, AL MONROE COUNTY BOARD OF EDUCATION ABC PROJECT NO Attachments: 10 Page (8.5 X11 ) END OF ADDENDUM NUMBER 4 PREPARED BY 2660 EastChase Lane, Suite 200 Montgomery, Alabama Tel GMCNETWORK.COM Goodwyn, Mills and Cawood, Inc. GOODWYN, MILLS & CAWOOD, INC. ADDENDUM NO. 4 GMC PROJECT NO. AMGM of 2
3 903 SOUTH PERRY STREET MONTGOMERY, ALABAMA T F bmce@bordenandmorris.com May 07, 2014 Goodwyn Mills and Cawood Attn: Carla Young 2660 East Chase Lane, Suite 200 Montgomery, AL RE: Monroe Intermediate School Dear Carla, Please include the following changes in your next addendum on the above mentioned project as follows: ELECTRICAL DRAWINGS 1. Refer to Sheet E1.01a Lighting Floor Plan Level 1 and 2 a. Provide exit sign above door at coach box A201 and Storage A101. Connect to unswitched hot leg from lighting circuit serving area. 2. Refer to Sheet E1.01a Lighting Floor Plan Level 2 a. Note indicating mounting height for Type 'B' fixture at north end shall read 'Mount Type BE' Fixture 8' 0" A.F.F. in lieu of 'Mount Type E' Fixture 8' 0" A.F.F. 3. Refer to Sheet E1.01d Power Riser Diagram, Note 1 a. AIC rating for breaker being added to existing panel 'AC1' shall be 10K AIC. 4. Refer to Sheet E1.02d Boys and Girls Locker Room Electrical Plans a. Breakers added to serve new electric water coolers shall have an AIC rating of 10K AIC. 5. Refer to Sheet E1.03d Vestibule D109 a. Add Type 'EM' Fixture in vestibule D109 and in corridor adjacent to new double doors. Also provide a fire alarm pull station and horn strobe device in vestibule D109. See attached sheet ADE 1 for location and devices. 6. Refer to Sheet E1.03d Electrical Plans Secretary/Bookkeeper a. All breakers being added in existing panel 'AC1' shall have a AIC rating of 10K AIC. 7. Refer to Sheet E1.04d Notes a. All breakers being added in existing panel 'EXMP' shall have AIC rating of 10K AIC. D. Stanley Borden, P.E., ELECTRICAL James H. Morris, P.E., MECHANICAL D. Morgan Garner, P.E., ELECTRICAL
4 Page 2 of 3 8. Refer to Sheet E2.01 Fixture Schedule a. Delete Type 'F2E' from schedule. 9. Refer to Sheet E2.01 Legend a. Receptacle mark for dehumidifier shall be 'DH' in lieu of 'HD'. 10. Refer to Sheet E1.01b Weight Room Electrical Plan a. Provide electrical connection for WH 5. See attached sheet ADE 2 for requirements. 11. Refer to Sheet E1.02d Boys Locker Room a. Electrical Plan, see attached sheet ADE 3 for revised lighting fixture lay out. 12. Refer to Sheet E1.02d Girls Locker Room a. Electrical Plan, see attached sheet ADE 4 for revised lighting fixture layout. MECHANICAL DRAWINGS 1. Refer to Sheet M1.01b J.F. Shields Weight Room a. Change unit designations for Wall Pack Heat Pumps from TWHP 1 and TWHP 2 to WPHP 1 and WPHP 2 to match detail on sheet M2.01 and schedule on Sheet M3.01. Exhaust Fan Schedule: Change interlock designation for EF 1 from TWHP 1 to WPHP 1 Change interlock designation for EF 2 from TWHP 2 to WPHP Refer to Sheet M1. 01b J.F. Shields Storage Room a. Exhaust Fan EF 3 shall be controlled by a separate wall switch. Add note legend note #7 to read as follows: "Provide and install a complete operational exhaust fan with all related controls, wiring, mounting hardware, accessories, etc. (Provide egg crate grille on face of exhaust fan) Interlock exhaust fan with separate wall switch (See electrical plans)". 3. Refer to Sheet M1.01d Monroeville Middle School Girls Locker Room/Janitors Closet a. Provide High and Low combustion air to accommodate new gas water heater (See plumbing plans for gas water heater). Add note legend note #15 to read as follows: "Provide two 8"x6" combustion air ducts terminate one 12" below finished ceiling and terminate one 12" above finished floor. Run both ducts to sheet metal plenum behind louver". Add combustion air louver L 5 to Louver Schedule on Sheet M3.01. See attached Addendum Drawing ADM Refer to Sheet M3.01 Louver Schedule a. Add louvers L 3 and L 4 to schedule. See attached Addendum Drawing ADM 1. D. Stanley Borden, P.E., ELECTRICAL James H. Morris, P.E., MECHANICAL D. Morgan Garner, P.E., ELECTRICAL
5 Page 3 of 3 PLUMBING DRAWINGS 1. Refer to Sheet P1.01b Enlarged Plumbing Plan Weight Room "New Work" a. Add Service Sink (SS 1) and Water Heater WH 5 in weight room B103. See addendum drawing ADP Refer to Sheet P2.02 Plumbing Fixture Schedule a. Add Service Sink SS 1. See addendum drawing ADP Refer to Sheet P2.02 Water Heater Schedule a. Add Water Heater WH 5. See addendum drawing ADP 2. SPECIFICATIONS 1. Refer to Electrical Specifications Section a. Part 1 General: Paragraph 1.1 A, Remove references for "Vol#1, Moore Hall and Vol#3, Clement Hall". See revised specifications. 2. Refer to Electrical Specifications Section a. Part 1 General: Paragraph 1.1.6, "Simplex and Gamewell FCE added as options for Fire Alarm System Manufacturer's". See revised specifications. 3. Refer to Plumbing Specifications Section Plumbing Fixtures a. Part 2 Products: Paragraph 2.1 B, Add "Service Sink SS 1: 22 x 18, Florestone Model FM (white) or approved equal. Faucet: Florestone or approved equal. Supplies with stops: McGuire or approved equal. Drain and p trap: McGuire or approved equal". See revised specifications. 4. Refer to Plumbing Specifications Section Electric Water Heaters a. Part 2 Products: Paragraph 2.1 A, Add "Water Heater (WH 1 and WH 5): Electric Water Heater (Tankless and instantaneous), 4.8 KW 240/1/ o F normal hand washing temperature replaceable filter, 1.5 GPM flow regulator or EEMAX ACCUMIX Model M , comparable products by: Chronomite or equal". See revised specifications. Borden Morris Garner Consulting Engineers RH/JB/RB/nb Addendum# D. Stanley Borden, P.E., ELECTRICAL James H. Morris, P.E., MECHANICAL D. Morgan Garner, P.E., ELECTRICAL
6
7 EX PROVIDE 120V CONNECTION TO STEP DOWN TRANSFORMER FOR CHIME. COORDINATE EXACT REQUIREMENTS WITH SUPPLIER UNICATOR PANEL FOR FIRE ALARM SYSTEM IN GYM. ER TO SHEET E1.04d FOR LOCATION RE ALARM PANEL. J 4 SEE NOTE 2 BELOW. F F EM 4 ONTROL AC1-20/1P VERIFY EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. J EED EPS EED FIRE ALARM CONNECTION NG SIMPLEX FIRE ALARM ODEL VERIFY EXACT MENTS WITH MANUFACTURER. 4 EM SEE NOTE 2 BELOW. EXISTING PANEL 'AC1' SEE NOTE 1 BELOW. N SCALE: 1/4"=1'-0" A L L NOTES: 1. EXISTING PANEL 'AC1' IS A GE, SURFACE MOUNTED, 400 AMP, MLO, 120/240V, 3Ø, 4W WITH 12 SPACES. ADD BREAKERS (10K AIC) AS PER PLAN INDICATES. 2. CONNECT TO EXISTING LIGHTING CIRCUIT SERVING AREA. VERIFY EXISTING LOAD ON CIRCUIT BEFORE ADDING NEW LOAD. 3. EXTEND EXISTING BOX OUT TO NEW WALL & PROVIDE NEW DEVICE & COVERPLATE. I A B A M A C E N S E D RENOVATION TO MONROE COUNTY SCHOOLS ADDENDUM NO. 4 MONROE COUNTY, ALABAMA DATE: JOB# AMGM D. No PROFESSIONAL E N G MORGA N I N E E R GA RN E R C A W O O D 2660 EastChase Lane, Suite 200 Montgomery, AL Tel GMCNETWORK.COM ADE-1
8
9 240V, 1Ø 4.8KW. L 2 3 EWC F1E EF-2 F1 2 M 1 MP-25/2P 2#10 & 1#10 (G) - 3/4"c. MP-5 F1 2 WH-5 240V, 1Ø 4.8KW. F1 1 MP-1,3 F1E F1 4 TWHP-2 FD 2 2 S 7 MP-90/2P 2#3 & 1#8 (G) - 1 1/4"c. N WEIGHT ROOM - ELECTRICAL PLAN SCALE: 1/4"=1'-0" A L L I A B A M A C E N S E D RENOVATION TO MONROE COUNTY SCHOOLS ADDENDUM NO. 4 MONROE COUNTY, ALABAMA DATE: JOB# AMGM D. No PROFESSIONAL E N G MORGA N I N E E R GA RN E R C A W O O D 2660 EastChase Lane, Suite 200 Montgomery, AL Tel GMCNETWORK.COM ADE-2
10
11 SEE NOTE 3 BELOW. EF-5 M GUH-1 F3 F3 F3E OC F3E SEE NOTE 1 BELOW. EXMP-20/1P (10K AIC) EWC OC RC F3 EX S EX F3 OC N 4 BOYS LOCKER ROOM - ELECTRICAL PLAN SCALE: 1/8"=1'-0" NOTES: 1. CONNECT TO EXISTING LIGHTING CIRCUIT SERVING AREA. VERIFY EXISTING LOAD ON CIRCUIT BEFORE ADDING NEW LOAD. 2. REFER TO SHEET E1.04d FOR FIRE ALARM DEVICES & EXISTING PANEL 'EXMP' LOCATION. 3. RECONNECT EXISTING 120V CIRCUIT TO NEW GAS HEATER AS REQUIRED. A L L I A B A M A C E N S E D RENOVATION TO MONROE COUNTY SCHOOLS ADDENDUM NO. 4 MONROE COUNTY, ALABAMA DATE: JOB# AMGM D. No PROFESSIONAL E N G MORGA N I N E E R GA RN E R C A W O O D 2660 EastChase Lane, Suite 200 Montgomery, AL Tel GMCNETWORK.COM ADE-3
12
13 EF-6 F3 M SEE NOTE 3 BELOW. F3 F3E F3 GUH-2 F3E OC F3 OC SEE NOTE 1 BELOW. EX F3 RC F3E A F1 A J F3 EX S EWC 2 OC F3 WH-4 (GAS) EXMP-20/1P (10K AIC) SEE NOTE 1 BELOW. EXISTING 120V CIRCUIT. RECONNECT TO WH-4 4 N GIRLS LOCKER ROOM - ELECTRICAL PLAN SCALE: 1/8"=1'-0" NOTES: 1. CONNECT TO EXISTING LIGHTING CIRCUIT SERVING AREA. VERIFY EXISTING LOAD ON CIRCUIT BEFORE ADDING NEW LOAD. 2. REFER TO SHEET E1.04d FOR FIRE ALARM DEVICES & EXISTING PANEL 'EXMP' LOCATION. 3. RECONNECT EXISTING 120V CIRCUIT TO NEW GAS HEATER AS REQUIRED. A L L I A B A M A C E N S E D RENOVATION TO MONROE COUNTY SCHOOLS ADDENDUM NO. 4 MONROE COUNTY, ALABAMA DATE: JOB# AMGM D. No PROFESSIONAL E N G MORGA N I N E E R GA RN E R C A W O O D 2660 EastChase Lane, Suite 200 Montgomery, AL Tel GMCNETWORK.COM ADE-4
14
15 4 L-5 L-4 14 EF-6 5 PROVIDE "J" RETURN GRILLE OVER INTERIOR FAN OPENING - SIZE GRILLE TO MATCH LOUVER OPENING PROVIDE TWO 8"X6" COMBUSTION AIR DUCTS - TERMINATE ONE 12" BELOW FINISHED CEILING AND TERMINATE ONE 12" ABOVE FINISHED FLOOR. RUN BOTH DUCTS TO SHEET METAL PLENUM BEHIND LOUVER. 4 N (REF: SHEET M1.01d) EXCEL MON. M.S. MON. M.S. MON. M.S. MON. M.S. 4 SYMBOL TYPE EXT. SP H₂O SIZE MIN. SQ. FEET FREE AREA REMARKS SCHEDULE NOTES: I = INTAKE, R = RELIEF 1. RUSKIN MODEL ELC 6375P OR APPROVED EQUIVALENT. PROVIDE MOTORIZED SHUTTER, BIRD-SCREEN AND THE AMCA SEAL. PROVIDE BAKED ENAMEL FINISH TO MATCH BUILDING. ARCHITECT TO SELECT COLOR. 2. RUSKIN MODEL ELF 6375D OR APPROVED EQUIVALENT. PROVIDE BIRD-SCREEN AND THE AMCA SEAL. PROVIDE WITH BAKED ENAMEL FINISH TO MATCH BUILDING. ARCHITECT TO SELECT COLOR. CFM L-1 I.05 16" X 16" L-1 R.05 32" X 16" L-2 R.05 32" X 16" MATCH FAN L-3 AND L-4 R OPENING L-5 I.05 16"X16" (REF: SHEET M3.01) RENOVATION TO MONROE COUNTY SCHOOLS ADDENDUM NO. 4 MONROE COUNTY, ALABAMA DATE: JOB# AMGM C A W O O D ADM-1
16
17 11 1-1/2" 13 WH " 9 L UR " " 15 2" 10 4 EWC " WC-1 1 2" 2" 2" 1/2" SS-1 1/2" WH-5 1/2" 3/4" 1/2" 1" NEW WORK N SCALE: 1/4"=1'-0" (REF: SHEET P1.01b) RENOVATION TO MONROE COUNTY SCHOOLS ADDENDUM NO. 4 MONROE COUNTY, ALABAMA DATE: JOB# AMGM C A W O O D 2660 EastChase Lane, Suite 200 Montgomery, AL Tel GMCNETWORK.COM ADP-1
18
19 MARK FIXTURE COLD HOT WASTE REMARKS WC-1 WATER CLOSET (H/C) 1/2" --- 4" FLOOR MOUNTED, TANK TYPE, H/C WC-2 WATER CLOSET (H/C) 1" --- 4" FLOOR MOUNTED, FLUSH VALVE, H/C WC-3 WATER CLOSET 1" --- 4" FLOOR MOUNTED, FLUSH VALVE UR-1 URINAL (H/C) 3/4" --- 2" WALL MOUNTED, FLUSH VALVE, HANG 17" LIP TO FINISHED FLOOR. UR-2 URINAL 3/4" --- 2" WALL MOUNTED, FLUSH VALVE L-1 LAVATORY (H/C) 1/2" 1/2" 1-1/2" WALL MOUNTED WITH LEVER HANDLES, HANG 34" RIM TO FINISHED FLOOR L-2 LAVATORY 1/2" 1/2" 1-1/2" WALL MOUNTED WITH LEVER HANDLES SH-1 SHOWER (H/C) 1/2" 1/2" 2" S.D. PROVIDE HAND HELD SHOWER, 60" FLEX HOSE, SLIDE BAR AND FOLD DOWN SEAT SH-2 SHOWER 1/2" 1/2" 2" S.D. WALL MOUNTED BOX TYPE SHOWER UNIT EWC-1 ELECTRIC WATER COOLER (H/C) (BI-LEVEL) 1/2" 1/2" 1-1/2" WALL HUNG, HANG 36" SPOUT TO FINISHED FLOOR H/C SIDE JS-1 JANITORS SINK 1/2" 1/2" 3" FLOOR MOUNTED WITH TRAP STANDARD, PROVIDE CARRIER SS-1 SERVICE SINK 1/2" 1/2" 3" FIBERGLASS WITH LEGS FIXTURE SCHEDULE NOTES: HANDLE TO WIDE SIDE OF STALL. INSULATE P-TRAP, DRAIN AND SUPPLIES WITH HANDI LAV GUARD INSULATION KIT #102W OR EQUAL BY TRAP WRAP AND McGUIRE PRO WRAP. PROVIDE WITH STAINLESS STEEL FINISH AND SAFETY BUBBLER LEAD FREE. (REF: SHEET P2.02) MARK STORAGE CAPACITY 100 F T KW VOLT PH CY REMARKS WH ,4 WH ,2,3 WH ,2,3 WH ,4 ELECTRIC WATER HEATER SCHEDULE NOTES: 1. PROVIDE THREE YEAR WARRANTY. 2. PROVIDE EXPANSION TANK (SEE SPEC.) 3. BASED ON RHEEM MODEL EGSP30 OR EQUAL BY A.O. SMITH OR RUDD. 4. BASED ON EEMAX MODEL EGSP10 OR EQUAL. (REF: SHEET P2.02) RENOVATION TO MONROE COUNTY SCHOOLS ADDENDUM NO. 4 MONROE COUNTY, ALABAMA DATE: JOB# AMGM C A W O O D 2660 EastChase Lane, Suite 200 Montgomery, AL Tel GMCNETWORK.COM ADP-2
20
ADDENDUM NO. 2. The Bid Opening has not changed it remains December 8, 2016 AT 1:30 P.M.
ADDENDUM NO. TO: PLANS AND SPECIFICATIONS FOR STATE OF MISSOURI Health Center Renovation Missouri School for the Blind NO. E60-0 The Bid Opening has not changed it remains December 8, 06 AT :30 P.M. GENERAL
More informationBIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D
HOSKINS ARCHITECTURE, LLC 1721 4 th AVENUE NORTH, SUITE 101 BIRMINGHAM, ALABAMA 35203 205.321.4122 ADDENDUM NO. 7 PROJECT: BIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D HOSKINS
More informationADDENDUM NO. 4 November 15, Page 1
ADDENDUM NO. 4 November 15, 201 8 Page 1 PROJECT MANUAL FOR CONSTRUCTION OF HVAC REPLACEMENT FOR NORTH OCONEE HIGH SCHOOL FOR OCONEE COUNTY SCHOOLS WATKINSVILLE, GEORGIA DATED: SEPTEMBER 14, 2018 CUNNINGHAM,
More informationRENOVATION OF THE FARMERS MARKET Reference Number:
RENOVATION OF THE FARMERS MARKET Reference Number: 13-098 A D D E N D U M NO. 1 The following shall form part of the tender documents issued by the City of Guelph s Purchasing Department, June, 2013. NOTE:
More informationNCIDQ Restroom Drawing. Answers to the most common questions about this drawing for the Practicum Qpractice
NCIDQ Restroom Drawing Answers to the most common questions about this drawing for the Practicum. 2016 Qpractice Table of Contents This is a summary guide of most frequently asked questions about the Practicum
More informationWayne State University. Prentis Building Renovation. NM Project Number: Niagara Murano 2215 Cole Street Birmingham, Michigan, 48009
ADDENDUM NO 2 OWNER: Wayne State University DATE: January 4 th, 2019 PROJECT: NM Project Number: 18113.0 ARCHITECT: ENGINEER: Niagara Murano 2215 Cole Street Birmingham, Michigan, 48009 IMEG 26200 Town
More informationWendell E Green Elementary School 1150 W 96th St Chicago, IL 60643
11 W 9th St Chicago, IL 3 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will
More informationMahalia Jackson Elementary School 917 W 88th St Chicago, IL 60620
W 88th St Chicago, IL 0 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will
More informationADDENDUM NO: 1 IFB/RFP No: NKU Commodity: Kentucky Hall Renovation Date: 12/7/2017 Due Date: 12/18/2017
Procurement Services Lucas Administrative Center, 617 1 Nunn Drive Highland Heights, KY 41099 859.572.6605 FAX 859.572.6995 ADDENDUM NO: 1 IFB/RFP No: NKU-22-18 Commodity: Kentucky Hall Renovation Date:
More informationMarcus Moziah Garvey Elementary School S Morgan St Chicago, IL 60643
Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item
More informationSTEM Magnet Academy. Definitions EXTERIOR W Fillmore St Chicago, IL 60607
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationFriedrich Ludwig Jahn Elementary School 3149 N Wolcott Ave Chicago, IL 60657
39 Wolcott Ave Chicago, IL Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will
More informationEPIC Academy High School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationJohn Milton Gregory Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationAmos Alonzo Stagg Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationAlexander Graham Bell Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationMSU Barnard Hall 105 Cleanroom Installation PPA # Page 1
ADDENDUM NUMBER 1 DATE: February 10, 2017 PROJECT: MSU Barnard Hall Room 105 Cleanroom Installation PPA# 16-0002 (Consulting Design Solutions, Inc. Project # 1613) BID DATE: February 23, 2017 2:00 PM,
More informationADDENDUM NO. 3, March 14, 2017 A.B.C. No
ADDENDUM NO. 3, March 14, 2017 A.B.C. No. 2017044 RE: UM Harman Hall Mechanical Renovation Montevallo, Alabama 35115 Architect s job no. 2747 FROM: TurnerBatson 1950 Stonegate Drive, Suite 200 Birmingham,
More informationHiram H Belding Elementary School 4257 N Tripp Ave Chicago, IL 60641
Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item
More informationJackie Robinson Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationWendell Smith Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationCharles P Caldwell Academy of Math & Science ES 8546 S Cregier Ave Chicago, IL 60617
S Cregier Ave Chicago, IL 0 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will
More informationREAR FRONT 93' 20' 12' 48' 120' 30' 52' 75' Sample Shopping Center. Unit # 5 +/- 10,920 GLA GROUND FLOOR. Width +/- 105' Depth +/- 120' Site Map
Electrical Information Breaker Panel 1: Service Type: 120/208 Panel Type: LP2 Panel Number: CHH31500 Manufacturer: Cutler Hammer Amps: 150 Location: Back Room Breaker Panel 2: Service Type: 120/208 Panel
More informationBUILDING PLAN REVIEW REQUIREMENTS
TOWNSHIP OF NORTH FAYETTE BUILDING DEPARTMENT COMMERCIAL PLAN REVIEW REQUIREMENTS BUILDING PLAN REVIEW REQUIREMENTS In order to perform a thorough Building Plan Review, the following specifications, drawings
More information2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - FIXTURES AND TRIM
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 22 40 00 PLUMBING - FIXTURES AND TRIM A. Furnish all labor and materials required and install the following Plumbing Fixtures and companion Fixture Trim complete
More informationMarcus Moziah Garvey Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationJohn Spry Elementary Community School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationJames Shields Middle School 2611 W 48th St Chicago, IL 60632
2 W 48th St Chicago, IL 02 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will
More informationMarshall Truck Station Laboratory Addition Project No. TZ MnDOT
Marshall Truck Station Laboratory Addition Project No. TZ-91523 MnDOT 13-6574 ADDENDUM NUMBER 2 DATED September 19, 2013 Marshall Truck Station Laboratory Addition Project No. TZ-91523 MnDOT 13-6574 Architect:
More informationRichard J Oglesby Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationCharles G Hammond Elementary School 2819 W 21st Pl Chicago, IL 60623
Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item
More informationSECTION PLUMBING FIXTURES
SECTION 224000 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes 1. Faucets for lavatories and sinks. 2. Flushometers. 3. Toilet seats. 4. Protective shielding guards. 5. Fixture
More informationADDENDUM NO. 4 TO THE CONTRACT DOCUMENTS SUPPLEMENTAL INFORMATION
July 6, 2011 City of Miami Fire Station #13 ADDENDUM NO. 4 TO THE CONTRACT DOCUMENTS SUPPLEMENTAL INFORMATION This Addendum is issued to modify the previously issued Bidding and Contractual Documents,
More informationEverett McKinley Dirksen Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationNathanael Greene Elementary School 3525 S Honore St Chicago, IL 60609
athanael Greene Elementary School 32 S Honore St Chicago, IL 009 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the
More informationUniversity of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL
SECTION 23 00 10 - MECHANICAL SCOPE OF WORK PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01
More informationADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON
The City of Vaughan Procurement Services Department 2141 Major Mackenzie Drive Vaughan, ON L6A 1T1 Tel (905) 832-8555 ADDENDUM NOTICE ADDENDUM NO. 3 Total of (5) page BID NO. T18-003 DESCRIPTION: INTERIOR
More informationPhilip Rogers Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationLangston Hughes Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationADDENDUM NO. TWO. To the Plans and Specifications for: PALM COAST READINESS CENTER PALM COAST, FL For FLORIDA DEPT. OF MILITARY AFFAIRS
ADDENDUM NO. TWO To the Plans and Specifications for: PALM COAST READINESS CENTER PALM COAST, FL For FLORIDA DEPT. OF MILITARY AFFAIRS Prepared By: ARCHITECT Bhide & Hall Architects, P.A. 1329-C Kingsley
More informationDaniel S Wentworth Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationJonathan Burr Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationUniversity of Chicago Charter - Carter G Woodson
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationRobert Fulton Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationEmmett Louis Till Math and Science Academy 6543 S Champlain Ave Chicago, IL 60637
Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item
More informationAnswer: Only to ChurchWoods, LLC.
ADDENDUM ADDENDUM NO.: 3 DATE: 06/27/16 PROJECT: CHW ChurchWoods PROJECT ADDRESS: 4130 Old Post Road Charlestown, RI TO: All Bidders of Record: This Addendum forms a part of and modifies the bidding requirements
More informationADDENDUM THREE SPECIFICATIONS. Vincennes University Renovations of the Curtis G. Shake Learning Resources Center
ADDENDUM THREE Addendum Three (AD.03) to the drawings and specifications prepared by Gibraltar Design for Curtis G. Shake Learning Resources Center for Vincennes University, Vincennes, Indiana. All Contractors
More informationJohann W von Goethe Elementary School 2236 N Rockwell St Chicago, IL 60647
3 Rockwell St Chicago, IL Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will
More informationAccessible Toilet Stalls 6/18/03 1
Accessible Toilet Stalls 6/18/03 1 Section 11-4.17 Toilet Stalls Florida standard stall (11-4.17.3.1) In new construction the standard accessible stall shall contain an accessible lavatory within it, the
More informationJohn Harvard Elementary School of Excellence
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationMorton School of Excellence
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationJoseph E Gary Elementary School 3740 W 31st St Chicago, IL 60623
3 W 3st St Chicago, IL 3 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will
More informationHALL 1 & HALL 4 RESTROOM FINISH UPGRADE 100 SOUTH WEST TEMPLE, SLC, UT QUOTE # SLP42848 AUGUST 29, 2017 CONSTRUCTION DOCUMENTS ABBREVIATIONS
DRAWING INDEX HALL 1 & HALL 4 BID INFORMATION RESTROOM 100 SOUTH WEST TEMPLE, SLC, UT 84111 QUOTE # SLP42848 AUGUST 29, 2017 CONSTRUCTION DOCUMENTS ABBREVIATIONS CONSULTANTS OWNER SYMBOL LEGEND VICINITY
More informationDOCUMENT NARRATIVE PETSMART # 3131 GREEN VALLEY SAHUARITA, ARIZONA Construction Change Directive #1 (CCD-1) / September 22, 2017
These documents, indicated as Construction Change Directive #1 with a delta - 1, supersede the previous issue and should be inserted into the Construction Documents. The tags in the column indicate which
More informationThomas Chalmers Specialty Elementary School 2745 W Roosevelt Rd Chicago, IL 60608
W Roosevelt Rd Chicago, IL 8 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report
More informationArchitecture, Construction, and Engineering Technical Charter
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationJosefa Ortiz De Dominguez Elementary School 3000 S Lawndale Ave Chicago, IL 60623
3000 S Lawndale Ave Chicago, IL 023 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This
More informationJohn Palmer Elementary School 5051 N Kenneth Ave Chicago, IL 60630
Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item
More informationJoseph Lovett Elementary School 6333 W Bloomingdale Ave Chicago, IL 60639
Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item
More informationThomas A Edison Regional Gifted Center ES 4929 N Sawyer Ave Chicago, IL Co-locating on this campus are EDISON and ALBANY PARK
Facility Assessment Report 4929 Sawyer Ave Chicago, IL 025 Co-locating on this campus are EDISO and ALBA PARK This report contains a summary of the results from the facility assessment completed on the
More informationRufus M Hitch Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationAndrew Carnegie Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationM1.0 MECHNANICAL FLOOR PLAN
GENERAL NOTES A. CONTRACTORS AND SUB CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY
More informationHarriet Beecher Stowe Elementary School 3444 W Wabansia Ave Chicago, IL 60647
Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item
More informationDecember 31, 2015 A. THE BID OPENING DATE IS UNCHANGED. B. Questions, Additions, and Deletions
December 31, 2015 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA Y16-721-MM / ADDENDUM No. 1 ORANGE COUNTY CONVENTION CENTER PHASE III VALENCIA BALLROOM RENOVATION Bid Opening Date: January 12, 2016
More informationUniversity of Chicago Charter - NKO
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationPROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic
GENERAL SITE PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS Scope of work narrative Building code review Description of construction Documentation on drawings as List of applicable
More informationKIPP Charter Bloom. Definitions EXTERIOR S Lowe Ave Chicago, IL Co-locating on This Campus: Hope HS and Kipp Chtr Bloom
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationINVITATION TO TENDER ITT No. PS FIRE HALL 5 + HOUSING CONSTRUCTION. ADDENDUM No. 2 and AMENDMENT No. 2
FINANCE, RISK AND BUSINESS PLANNING Supply Chain Management May 17, 2016 INVITATION TO TENDER ITT No. PS20160468 FIRE HALL 5 + HOUSING CONSTRUCTION ADDENDUM No. 2 and AMENDMENT No. 2 RE: Various additions
More informationFranklin Elementary Fine Arts Center 225 W Evergreen Ave Chicago, IL 60610
22 W Evergreen Ave Chicago, IL 1 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report
More informationResidential Construction Checklist Single and Two Family Construction
DATE: _ Building Inspection Submittal Requirements Residential Construction Checklist Single and Two Family Construction Submit a City of Big Spring Permit Application, checklist, and 3 complete hard copy
More informationALL PLAN HOLDERS NANCY MAGER, NPSR ARCHITECTS, INC. DATE: November 29, Lea County General Service Building PROJECT NO: ADDENDUM NO: 1
A R C H I T E C T S, I n c. TO: ALL PLAN HOLDERS FROM: NANCY MAGER, NPSR ARCHITECTS, INC. DATE: November 29, 2018 PROJECT: Lea County General Service Building PROJECT NO: 18-142 ADDENDUM NO: 1 PAGES: 10
More informationGeorge Washington Elementary School 3611 E 114th St Chicago, IL 60617
3 E th St Chicago, IL Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up
More informationWilliam H Seward Communication Arts Academy ES 4600 S Hermitage Ave Chicago, IL 60609
S Hermitage Ave Chicago, IL 9 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report
More informationCharles N Holden Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationADDENDUM #2 September 12, 2018
Physical Plant Services Project Management 1000 Rim Drive Phone: (970) 247-7523 Fax: (970) 247-7555 Project No. 2007-130P18 Whalen Gymnasium Expansion and Renovation for Exercise Science Request for Qualifications
More informationCYPRESS FAIRBANKS MEDICAL CENTER HOSPITAL
T Architecture Interiors Planning 1165 BRITTMOORE RD. HOUSTON, TEXAS 7704 (T) 71.626.400 (F) 71.626.401 in association with: www.garnerfritsche.com CYPRESS FAIRBANKS MEDICAL CENTER HOSPITAL An HCA Affiliated
More informationNorth Lawndale College Prep Charter - Collins
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationInstallation Guide. Model #400. Corporate Office: 349 Highland Road East Macedonia, Ohio
Installation Guide Model #400 Corporate Office: 349 Highland Road East Macedonia, Ohio 44056 1.866.822.7328 www.ezbreathe.com Copyright 2006, EZ Breathe, LLC WHAT S INSIDE Before installing your EZ Breathe
More informationCHABOT- LAS POSITAS COMMUNITY COLLEGE DISTRICT
1 CHABOT- LAS POSITAS COMMUNITY COLLEGE DISTRICT Facilities Planning & Management Department August 11, 2010 Addendum No. 2 INVITATION FOR BID NO.: 11-07 Industrial Technology Center, Buildings 1400/1600
More informationLorenz Brentano Math & Science Academy ES 2723 N Fairfield Ave Chicago, IL 60647
Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item
More informationJoseph E Gary Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationIntroduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products
Plumbing Plans Introduction Classifications of piping: Industrial Carries liquids and gases used in the manufacture of products Residential (i.e., plumbing) Carries fresh water, gas, liquid, solid waste
More informationA. This Section includes plumbing fixtures and related components.
SECTION 224200 PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationPaul Cuffe Math-Science Technology Academy ES 8324 S Racine Ave Chicago, IL 60620
82 S Racine Ave Chicago, IL 020 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report
More informationDisney II Magnet School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationCyrus H McCormick Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationJohn Barry Elementary School 2828 N Kilbourn Ave Chicago, IL 60641
Kilbourn Ave Chicago, IL 0 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will
More informationDisney II Magnet High School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationJames Otis Elementary School 525 N Armour St Chicago, IL 60642
Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item
More informationAddendum. Windsor Hall Renovations Date: October 12, 2017 Addendum No: 3 GENERAL. 1! Addendum #4 will be issued 2:00 PM Tuesday October 17, 2017.
!!! Addendum EXP Project No: MTA Project No: WIND-17-01 Project: Windsor Hall Renovations October 12, 2017 Addendum No: 3 The following information supplements and/or supersedes the bid documents. This
More informationGeorge W Tilton Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationTo the Drawings and/or Specifications for. Board of Education of Harford County Lancaster, PA 17603
ENDUM NO. 2 To the Drawings and/or Specifications for Gilbert Architects Youth s Benefit Elementary School - #0729 626 N. Charlotte St. Board of Education of Harford County Lancaster, PA 17603 June 2,
More informationAcademy for Global Citizenship Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationBrian Piccolo Elementary Specialty School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationPMA ONLINE TRAINING. Commercial Drawings. One Hour Continuing Education
PMA ONLINE TRAINING Commercial Drawings One Hour Continuing Education PMA training disclaimer The information provided in this document is intended for use as a guideline and is not intended as, nor does
More informationGRADY BROWN PARK RESTROOM
PRES ERVAT ION P RIDE CONS E RVAT ION W A L T ON COU NT Y, DA F L OR I BUILDING PLANS FOR THE PREPARED FOR: PREPARED BY: WALTON COUNTY WALTON COUNTY BOARD OF COUNTY COMMISSIONERS PUBLIC WORKS DIVISION
More informationREVISION #1. Section. fire alarm B. C. the hot. intent of. required. manufacturer. materials. C. Warranty
HOT AISLE CONTAINMENT SYSTEM (HACS) REVISION #1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. B. C. Drawings and general provisions of the Contract, including General and Supplementary. Conditions apply to
More informationWilliam Penn Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationJames Monroe Elementary School 3651 W Schubert Ave Chicago, IL 60647
W Schubert Ave Chicago, IL 0 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report
More information