Bimetallic Thermometer

Size: px
Start display at page:

Download "Bimetallic Thermometer"

Transcription

1 Bimetallic Thermometer ~ Application It is one kind of t hermometers to measure middle and low temperature on the spot. It could be used to directly measure temperature of liquid, vapor and gas ranging from -0 to Features 1.directly display temperature on the spot 2.high reliability and long life expectancy 3.many structure forms to meet different demands Operation Theory Bimetallic thermometer is based on bimetal bended into ring shape. One side of bimetal expands in time of being heated, which results in revolving of indicator, then the meter will indicates the corresponding temperature value. 1. JB/T ,, 3. (1.0), s 5. IP % 7.. 1/2 9. Main Technical Parameters 1.Executive Standard JB/T Nominal Diameter of Dial:,, 3.Accuracy Class:(1.0),1.5 4.Thermal Response Time: 40s 5.Protection Class:IP55.Angle-adjusting Error It shall be no more than1% of its measuring range 7.Return Error It shall be no more than the absolute value of basic error limit..repeat The repeat range shall be no more than 1 /2 of absolute value of basic error limit. 9.Measuring Range Measuring Range Application Range -0~+40-40~+0 0~50 0~ 0~ 0~0 0~0 0~400 0~500 1

2 . Ambient Condition for Normal Operation Working Place Temperature( ) Relative Humidity % Sheltered Place -25~+25 5~ Outdoor -40~+5 5~ 11. Measuring End Integration Type Core Type Axial Radial 12. Figure & Size O 135 O 135 Angle Universal Structure Axial Radial o o Angle Universal A B C E L D Mounting & Fixing Outer Threaded Tube M H SW Mx1.5 Mx1.5 NPT1 /4 NPT1 /2 NPT3 / Outer Threaded Tube Inner Threaded Tube M H SW Mx1.5 Mx1.5 NPT1 /4 NPT1 /2 NPT3 / Inner Threaded Tube 2

3 Threaded M Mx1.5 Mx1.5 NPT1 /4 NPT1 /2 NPT3 /4 H SW Threaded Threaded with Fastener M H SW D M12x1.5 Mx1.5 Mx Threaded with Fastener Flange with Fastener D D 1 D 2 SW d 0 d Flange with Fastener D D 1 D 2 H d 0 d ANSI JB HG Remarks: We may provide flanges of ANSI, JB, HG or other standard. 3

4 Type Naming Method W W Temperature Instrument S S Metal Expansion Type S S Bimetal Thermal Element Nominal Shell Diameter o Location 0 Axial 1 Radial o Angle Universal Mounting & Fixing 0 without fixing device 1 Movalbe Outer Threaded 2 Inner Threaded 3 Threaded 4 5 Threaded with Fastener Flange with Fastener W F Protection Type Common Type Protection Type Corrosion-resistant Type W S S 4 1 W Model Example 4

5 Type & Specification Axial Type Type Measuring Range Accuracy Class Protection Tube Material D Specification L Mounting & Fixing Device WSS-0 WSS-400 WSS-500 WSS-1 WSS-401 WSS-501 WSS-2 WSS-402 WSS-502 WSS-3 WSS-403 WSS-503-0~+40-0~+40 0~+0 0~ 0~ 1.5 1CrNI9Ti 4 3 3L C-27 H Alloy C Outer Threaded Inner Threaded Threaded WSS-4 0 WSS-404 0~0 WSS-504 WSS-5 0~400 WSS-405 WSS-505 0~500 Threaded with Fastener WSS- WSS-40 Flange wih Fastener WSS-50 5

6 Radial Type Type Measuring Range Accuracy Class Protection Tube Material D Specification L Mounting &Fixing Devices WSS-3 WSS-4 WSS-5 WSS-311 WSS-411 WSS-511 WSS-312 WSS-412 WSS-512 WSS-313 WSS-413 WSS-513-0~+40-0~+40 0~+0 0~ 1.5 1CrNI9Ti Outer Threaded Inner Threaded Threaded WSS-314 WSS-414 0~ 3L 0 WSS-514 0~0 WSS-315 WSS-415 WSS-515 0~400 C-27 H Alloy C-27 Threader with Fastener WSS-3 0~500 WSS-4 Flange with Fastener WSS-5

7 o 135 o 135 Angle Type Type Measuring Range Accuracy Class Protection Tube Material D Specification L Mounting &Fixing Devices WSS-4 WSS-5 WSS-421 WSS-521 WSS-4 WSS-5-0~+40-40~+0 0~50 0~ 1CrNI9Ti 3 0 Outer Threaded Inner Threaded WSS-432 WSS-532 WSS-424 WSS-524 WSS-425 WSS-525 0~ 0~0 0~0 0~400 0~ L C-27 H Alloy C Threaded Threader with Fastener WSS-42 WSS-52 Flange with Fastener 7

8 Universl Type Type Measuring Range Accuracy Class Protection Tube Material D Specification L Mounting & Fixing Devices WSS-40 WSS-50 WSS-41 WSS-51 WSS-42 WSS-52-0~+40-40~+0 0~50 0~ 1CrNI9Ti 3 0 Outer Threaded Inner Threaded WSS-42 WSS-52 WSS-44 WSS-54 WSS-45 WSS-55 0~ 0~0 0~0 0~400 0~ L C-27 H Alloy C Threaded Threader with Fastener WSS-4 WSS-5 Flange with Fastener 1) 2) 3) 4) 5) ) A 0~ M27 X 2, 450mm, WSS-41 0~400 L=450 Notices in Type Selection 1) Type 2) Dial Diameter 3) Accuracy Class 4) Mounting & Fixing 5) Measuring Range ) Length or Insert Length Example A:Universal type, for dial diameter, measuring range 0~400,class 1.5, movable outer threadrd connector, length 450mm, WSS-41 0~400 L=450

9 Mounting Figures Vertically mounted into pipe Vertically mounted into pipe Mounted into bent pipe Mounted with flange connection Specification of Straight Code TH4A TH4B TH4C TH4D TH4E TH4F TH4G M D D1 D2 d h H Mx1.5 Mx1.5 M33x2 NPT1 /2 NPT3 /4 NPT

10 Code TH49A TH49B TH49C TH49D TH49E M D D1 d h H M33x2 NPT 1/ 2 NPT 3 /4 NPT Code TH50A TH50B TH50C TH50D TH50E TH50F M D D1 d H Mx1.5 Mx1.5 NPT1 /4 NPT1 /2 NPT3 /

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version Mechatronic temperature measurement Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version WIKA data sheet TV 17.01 for further approvals see page 6 Applications

More information

ANSI ORIFICE FLANGES METAL-KOREA

ANSI ORIFICE FLANGES METAL-KOREA METAL-KOREA ANSI ORIFICE FLANGES ORIFICE FLANGES are widely used in conjunction with orifice meters for measuring the rate of flow of liquids and gases. They are basically the same as standard welding

More information

Standard Bourdon tube pressure gauges EN 837-1

Standard Bourdon tube pressure gauges EN 837-1 Standard Bourdon tube pressure gauges EN 871 Application For gaseous and liquid media which are not highly viscous, do not crystallize and are not aggressive to copper alloys. For measuring gas or vapour,

More information

Magnetic level switches ERH-xx-20

Magnetic level switches ERH-xx-20 edit. II 2015/ page 5 Magnetic level switches ERH-xx-20 Description 3 Level signalling of the medium having minimum density 0,70 g/cm. The basic version, mounted from the top, is available with 92x92mm

More information

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions Thermal Structures Inc. FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions Attached Flange & Double Barrier System FLOOR TO FLOOR (F) ROOF TO ROOF (R) FLOOR TO WALL (FW) ROOF TO WALL (RW)

More information

0.20. Record Page 1 of 19

0.20. Record Page 1 of 19 Page 1 of 19 Page 2 of 19 Page 3 of 19 Page 4 of 19 Page 5 of 19 ASME BPVC.III.1.ND-2015 Page 6 of 19 ð15þ Figure ND-3325-1 Some Acceptable Types of Unstayed Flat Heads and Covers GENERAL NOTE: The illustrations

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,

More information

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering Change from one to two columns Data Sheet 10/10-3.61-EN Rev. D SensyTemp TSB (B R) Resistance thermometer for building automation, machine construction and environmental engineering Measurement made easy

More information

Resistance thermometers for process technology

Resistance thermometers for process technology Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available

More information

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HF) Sizes

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HF) Sizes 95. _ (disk pack HF) Sizes 6 22 Please read these Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to coupling failure, resulting

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

Fluid Sealing Association

Fluid Sealing Association Fluid Sealing Association STANDARD FSA-MG-501-02 STANDARD TEST METHOD FOR INWARD BUCKLING OF SPIRAL-WOUND GASKETS 994 Old Eagle School Road, Suite 1019 Wayne, Pennsylvania 19087-1866 Phone: (610) 971-4850

More information

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions... Flow meter Content F2-UN Description... 3 Technical data... 4 Dimension drawings... Operation... 8 Mounting instructions... 9 Order code... 10 F1-FP Description... 11 Technical Data... 12 Dimension drawings...

More information

WDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system

WDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system CONDUCTIVITY TRANSMITTR WDM-A (-wire type) WDM-6A (-wire type) It is a type of small firm aluminum -electrode site-installation CONDUCTIVITY TRANSMITTR (signal transmitter) and easy operate. The device

More information

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor sales@jumo.co.uk info.us@jumo.net Vorläufig V Page 1/8 JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor Cell constants K = 0.01 1.0 202922 Series for universal application, e.g.

More information

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring

More information

JB/T Translated English of Chinese Standard: JB/T

JB/T Translated English of Chinese Standard: JB/T Translated English of Chinese Standard: JB/T9249-1999 www.chinesestandard.net Sales@ChineseStandard.net MACHINERY INDUSTRY STANDARD OF JB THE PEOPLE S REPUBLIC OF CHINA ICS 17.120 N 12 JB/T 9249-1999 Replacing

More information

Indoor, outdoor and duct resistance thermometers

Indoor, outdoor and duct resistance thermometers Phone: 49 661 60030 Fax: 49 661 6003607 email: mail@jumo.net Phone: 44 1279 635533 Fax: 44 1279 635262 email: sales@jumo.co.uk 1800554JUMO Data Sheet 90.2523 Page 1/6 Indoor, outdoor and duct resistance

More information

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures. SECTION 22 05 16 LOOPS FOR PLUMBING PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Insertion Transducer On-line Install Instruction

Insertion Transducer On-line Install Instruction LOGO Insertion Transducer On-line Install Instruction Shanghai Dynameters Co., Ltd www.dynameters.com Insertion Transducer Installation Manual Installation steps 1. Locate Installing point 2. Weld mounting

More information

PureFlow PEX Crimp Zero Lead Fittings for Use with Viega PureFlow Tubing. Potable Water. Other

PureFlow PEX Crimp Zero Lead Fittings for Use with Viega PureFlow Tubing. Potable Water. Other Project: Engineer: Contractor: Submitted By: Potable Water Other 1 of 10 Technical Data Materials: Fittings... Eco Brass or Polymer Crimp Rings... Copper (black) MANABLOC Manifolds... Polysulfone (plastic)

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Screw-in resistance thermometers with terminal head Form B

Screw-in resistance thermometers with terminal head Form B Data Sheet 90.2002 Page 1/7 Screw-in resistance thermometers with terminal head Form B for temperatures from -50 to +600 C with replaceable measuring insert as single or twin resistance thermometer terminal

More information

Kerkau Manufacturing. B16.5 Flange Book

Kerkau Manufacturing. B16.5 Flange Book Kerkau Manufacturing B16.5 Flange Book TABLE OF CONTENTS Revision 1 Title Page Table of Contents Tolerance Page Permissible Imperfections Dimensions of Flange Facings (all pressure rating classes) Dimensions

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Technical Information Condumax CLS21D/CLS21

Technical Information Condumax CLS21D/CLS21 TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application

More information

Safety Angle Transducer Type Series Potentiometric, active

Safety Angle Transducer Type Series Potentiometric, active Special features Potentiometric measuring principle with conductive plastic resistance track and integrated signal amplifier Redundant design for safety relevant applications available Extremely rugged

More information

This is a motor attachment option in which the motors attach closely to the sides of the NXT.

This is a motor attachment option in which the motors attach closely to the sides of the NXT. 6 II. Ways to Attach NXT Motors 1. Simple Side Attachment Model Description: This is a motor attachment option in which the motors attach closely to the sides of the NXT. 7 These are the parts that you

More information

Sight glass window Sight flow indicator

Sight glass window Sight flow indicator SIGHT GLASS Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels. When it comes to selecting a sight glass, a wide variety of factors should be considered

More information

Mineral-insulated resistance thermometers to EN

Mineral-insulated resistance thermometers to EN Data Sheet 90.2221 Page 1/6 Mineral-insulated resistance thermometers to EN 60 751 for temperatures from -50 (-200) to +600 C flexible sheath with shock-protected sensor as single or twin resistance thermometer

More information

MAGNETIC 2000 SERIES BEARINGLESS ENCODERS FOR LARGE SHAFTS

MAGNETIC 2000 SERIES BEARINGLESS ENCODERS FOR LARGE SHAFTS MAGNETIC 2000 SERIES BEARINGLESS ENCODERS FOR LARGE SHAFTS Low-maintenance for large shafts Certain motors benefit from having the speed feedback sensor mounted directly on the main shaft. A bearingless

More information

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART I - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

PIPE/CONDUIT SUPPORTS

PIPE/CONDUIT SUPPORTS PIPE/CONDUIT SUPPORTS Pipe/Conduit Clamps...102-105 Unicushion... 106 Pipe & Tubing (Cush-A-Clamp ) Clamps...107-110 Pipe Hangers... 111 Pipe Rollers...111-112 Pipe Brackets... 113 Reference Tables...114-120

More information

USB 2.0-IP67 Water Resistant Connector System

USB 2.0-IP67 Water Resistant Connector System Section 6 USB 2.0-IP67 Water Resistant Connector System CONEC completed its product line of bayonet locking series, IP67 rated industrial USB 2.0 connector system for harsh environments. The housing can

More information

Sakura Endress RCV-1000/1200. Average Temperature Measuring Element for Tank Gauging System

Sakura Endress RCV-1000/1200. Average Temperature Measuring Element for Tank Gauging System Technical Information TI 002 N/08/en/02.02 Average Temperature Measuring Element for Tank Gauging System RCV-1000/1200 Multi-point average temperature with tank inventory management control Introduction

More information

Pressure Vessel Assembly Instructions

Pressure Vessel Assembly Instructions Pressure Vessel Assembly Instructions 1) Measure aluminum tube outer diameter 2) Machine both end caps and only drill pilot holes for all hoes shown 3) Weld both end caps onto the aluminum tube and be

More information

SPINNER Rotating Solutions

SPINNER Rotating Solutions SPINNER Rotating Solutions Fiber Optic Rotary Joints Edition C/2016 HIGH FREQUENCY PERFORMANCE WORLDWIDE www.spinner-group.com SPINNER is one of the leading manufacturers for high performance rotary joints

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

THERMOWELLS CONSTRUCTION FROM BARSTOCK OR FABRICATED

THERMOWELLS CONSTRUCTION FROM BARSTOCK OR FABRICATED age 1 of 5 THERMOWELLS CONSTRUCTION FROM BARSTOCK OR FABRICATED A thermowell is a thermally conductive socket recommended to: rotect the delicate instrument sensing elements against corrosive effects.

More information

Kiosk Solution W1000. Installation and Assembly Instructions July 2015 Edition

Kiosk Solution W1000. Installation and Assembly Instructions July 2015 Edition Kiosk Solution W1000 Installation and Assembly Instructions July 2015 Edition All product names mentioned in this document are the trademarks, brands or registered trademarks of their respective owner.

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Product Information. EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface

Product Information. EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface Product Information EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface 11/2017 EQN 1337 F Rotary encoders for absolute position values Installation diameter 65 mm

More information

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter Data Sheet DS/FCB300/FCH300-EN Rev. H CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter 4-wire compact device For flow measurement of liquids and gases Measurement made easy CoriolisMaster

More information

Specification. Hercules MA520.A.BC.008

Specification. Hercules MA520.A.BC.008 MA520.A.BC.008 on ground-plane Hercules MA520.A.BC.008 Specification Part No. Product Name MA520.A.BC.008 Hercules 2in1 Cellular and Wi-Fi Heavy Duty Screw Mount Antenna - Cellular 2G/3G HSPA/GSM/GPRS/CDMA/EVDO/UMTS/WCDMA

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Temperature OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 11 Applications Machine building, plant and vessel construction

More information

( This link will provide you with a list of all ISO-6983 G-Codes

(  This link will provide you with a list of all ISO-6983 G-Codes CUSTOM HAZARDS CUSTOM HAZARDS CUSTOM HAZARDS In this lesson I am going to explain how to circle interpolate a 1/8-27 NPT with a formed thread E-Mill using G-Code on a vertical mill. I have provided the

More information

Smart Displacer Level (Interface) Transmitter DLT100 Series

Smart Displacer Level (Interface) Transmitter DLT100 Series Smart Displacer Level (Interface) Transmitter DLT100 Series Equipped with FISHER FIELDVUE DLC3010 1 Introduction DLT100 series is Smart Displacer Level (Interface) Transmitter equipped with the original

More information

Optical encoder MEC22 HR

Optical encoder MEC22 HR Optical encoder MEC22 HR Description The MEC22 HR is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square

More information

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES 6GHz Intelligent Radar Level Meter Product Manual Model:KRD520 SERIES Directory 1 Product Overview...1 2 Product Introduction...2 3 The Installation Requirements...4 4 The Electrical Connection...6 5 Instrument

More information

SERIESN50, COAXIAL CONNECTORS

SERIESN50, COAXIAL CONNECTORS SERIESN50, COAXIAL CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER N connectors are available with 50 and 75 impedance. The frequency range extends to 18 GHz, depending on the connector and cable type.

More information

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET INCH-POUND MIL-DTL-83723/83E 25 January 2018 SUPERSEDING MIL-DTL-83723/83E 1 October 2009 DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, ENVIRONMENT RESISTING, RECEPTACLE, FLANGE MOUNT, THREADED

More information

Precision Thermistor Sensors

Precision Thermistor Sensors Precision Thermistor Sensors For Laboratory Applications ON-400 Series U For Use in Laboratory or Other High-Accuracy Applications U Rugged Construction Can Be Used for Short Term Water and Soil Readings

More information

Technical features. Positive Taper Lock System for manual tool clamping. Technical features:

Technical features. Positive Taper Lock System for manual tool clamping. Technical features: clamping set Technical features The RÖHM- was specially designed for the positive taper lock clamping taking particulary into account the necessity of manual clamping. Technical features: strong design

More information

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET INCH-POUND MIL-DTL-83723/82E 25 January 2018 SUPERSEDING MIL-DTL-83723/82E 19 August 2009 DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, ENVIRONMENT RESISTING, RECEPTACLE, FLANGE MOUNT, THREADED

More information

Type XTSR71 Sizes

Type XTSR71 Sizes (Page 1 of 13) s 494-5258 Type XTSR71 s 494-5258 Figure 1 Thomas XTSR71 Coupling 1. General Information 1.1 Thomas Couplings are designed to provide a mechanical connection between the rotating shafts

More information

CF Series AXC5/AXC6. FEATURES 1. Vertical mating type with a 0.8 mm mated height low profile design

CF Series AXC5/AXC6. FEATURES 1. Vertical mating type with a 0.8 mm mated height low profile design For board-to-micro coaxial wire Micro coaxial connectors (Low profile) AC5/AC6 CF Series 2. with strong resistance to various environments provides high contact reliability and facilitates connection work

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC

More information

INSTALLATION MANUAL for KLINGER gaskets

INSTALLATION MANUAL for KLINGER gaskets INSTALLATION MANUAL for KLINGER gaskets INSTALLATION TIPS FOR KLINGER GASKETS SUITABILITY Check on chemical resistance STORAGE Check on storage conditions PT-DIAGRAMS Review the pt-diagrams INSTALLATION

More information

ECT Applications. Features

ECT Applications. Features ECT 847 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET INCH-POUND MIL-DTL-83723/59D 26 August 2010 SUPERSEDING MIL-DTL-83723/59D 29 June 2009 DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, (CIRCULAR, ENVIRONMENT RESISTING), PROTECTIVE COVERS, PLUGS, (FOR

More information

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING ELECTROMAGNETIC FLOW METERS The electromagnetic flow meter is used to measure the flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and

More information

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm Electrical contacts stainless steel thermometers T11 - T12 - T13 Ø - Ø 1 - Ø 160 mm Derived from the TX thermometers of nominal diameter, 1 and 160, of which they possess all the characteristics, the T11,

More information

SGMMV. Rotary Servomotors SGMMV - A1 A 2 A 2 1. Model Designations. 6th. 5th digit. 1st+2nd digits. 7th digit. 4th digit. 3rd digit.

SGMMV. Rotary Servomotors SGMMV - A1 A 2 A 2 1. Model Designations. 6th. 5th digit. 1st+2nd digits. 7th digit. 4th digit. 3rd digit. Rotary s Model Designations - mini Series st+nd digits 3rd digit th digit th digit 6th digit 7th digit st+nd digits Rated Output th digit Design Revision Order 7th digit Options Code Code Code B3 3.3 W

More information

Resistance Thermometers Model Series TR7X0, Sheathed Design

Resistance Thermometers Model Series TR7X0, Sheathed Design Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features

More information

CP6A. 6 Band Trap Vertical 75-6m

CP6A. 6 Band Trap Vertical 75-6m CP6A 6 Band Trap Vertical 75-6m Instruction Sheet The CP6A is a multi-band trap-vertical antenna for HF bands, covering the 75*, 40, 20, 15, 10m & 6m amateur bands. Made from heavy duty aluminum, the CP6A

More information

IN-LLT-C. Submersible Level Transmitter. 1.1 Description. 2.1 Specifications.

IN-LLT-C. Submersible Level Transmitter. 1.1 Description. 2.1 Specifications. IN-LLT-C Submersible Level Transmitter 1.1 Description. The Intech IN-LLT-C hydrostatic level transmitter is a fully sealed submersible pressure instrument. It is designed for liquid level measurement.

More information

Armoured Power and Control Cables to BS7917

Armoured Power and Control Cables to BS7917 1 Armoured Power and Control Cables to BS Fire Resistant, TAC. MGT. EPR. ZH. GSWB. SW, 00/00 V. Low Smoke Zero Halogen Application Armoured cables for fixed wiring in ships and offshore units where circuit

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.) ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economic transmitter

More information

CAM SYSTEM. Eccentric self-locking clamping devices. Set. CAM SYSTEM t. CAM SYSTEM t. Set. CAM SYSTEM s pag CAM SYSTEM s pag.

CAM SYSTEM. Eccentric self-locking clamping devices. Set. CAM SYSTEM t. CAM SYSTEM t. Set. CAM SYSTEM s pag CAM SYSTEM s pag. Eccentric self-locking CAM SYSEM Set CAM SYSEM t pag. 12 CAM SYSEM t pag. 126 Set CAM SYSEM s pag. 127 CAM SYSEM s pag. 128 EDGE CLAMP pag. 130 123 CAM-SYSEM eccentric self-locking he CAM SYSEM has been

More information

Lengths [7] Ø.50 [13] [7] [13]

Lengths [7] Ø.50 [13] [7] [13] Dimensions in [ ] are in millimeters Standard (2 1 / 2 6 ) Standard (9 24 ).75 STEM.40 [10] EXTERNAL THREAD.61 [15] 1.00 [25] STEM STEM Ø.44 [11] Threaded-Stepped Shank Standard Stem Length Length (T)

More information

3. HIWIN rotary tables TMS

3. HIWIN rotary tables TMS CRD Devices Ltd All Saints Industrial Estate, Shildon, Co, Durham, DL4 2RD Tel: +44 ()1388 7784 Fax: +44 ()1388 7788 E: sales@crd-devices.co.uk W: www.crd-devices.co.uk 3. HIWIN rotary tables TMS 3.1 Characteristics

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Armoured Power and Control Cables Fire Resistant

Armoured Power and Control Cables Fire Resistant Armoured Power and Control Cables Fire Resistant Low Smoke Zero Halogen TAC. MGT. EPR. ZH. GSWB. SW, 00/00V Application Armoured cables for fixed wiring in ships and offshore units where circuit integrity

More information

The Low-Noise, Integrated Transformer Helium-4 Dipstick Insert

The Low-Noise, Integrated Transformer Helium-4 Dipstick Insert The Low-Noise, Integrated Transformer Helium-4 Dipstick Insert Sang Lin Chu Georgia Institute Of Technology 837 State Street N.W. Atlanta, GA 30332 gte813m@prism.gatech.edu, sanglinchu@hotmail.com December

More information

ELECTRIC CURRENT VERY SHORT ANSWER QUESTIONS

ELECTRIC CURRENT VERY SHORT ANSWER QUESTIONS ELECTRIC CURRENT VERY SHORT ANSWER QUESTIONS 1. Give the equivalent of V A -1. 2. Ten identical wires, each having a resistance of one ohm, are joined in parallel. What is the equivalent resistance of

More information

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector No. SS2-MGN200-0200 MagneW3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIEW The MagneW3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter

More information

CP6 6 Band Trap Vertical 80-6m

CP6 6 Band Trap Vertical 80-6m CP6 6 Band Trap Vertical 80-6m Instruction Sheet The CP6 is a multi-band trap-vertical antenna for HF bands, covering the 80*, 40, 20, 15, 10m & 6m amateur bands. Made from heavy duty aluminum, the CP6

More information

SIGHT GLASS. Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels.

SIGHT GLASS. Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels. SIGHT GLASS Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels. SIGHT GLASS Sight flow indicator. A sight flow indicator is used in process pipelines

More information

Magnetic Inductive Flow Sensors VMI Series

Magnetic Inductive Flow Sensors VMI Series Magnetic Inductive Flow Sensors VMI Series SIKA Dr.Siebert & Kühn GmbH & Co. KG Struthweg 7 9 34260 Kaufungen Germany.: +49 5605 803-0 Fax: +49 5605 803-54 e-mail: info@sika.net www.sika.net Magnetic Inductive

More information

M1 series 2 way ball valve with integrated Praher Labeling System

M1 series 2 way ball valve with integrated Praher Labeling System General: Material: PVC-U Seal material: EPDM / FPM Ball seating joint: PTFE Dimensions: DN10 DN50 d16 d63 d3/8 d2 Connection types: Solvent socket DIN / ASTM / JIS Solvent spigot DIN Threaded socket BSP

More information

847H. Description. Features. Specifications

847H. Description. Features. Specifications 847H Bulletin 847H High Performance Industrial Incremental Encoders provide code disk resolutions of up to 65536 pulses per revolution at a signal frequency response of 820 khz. The 847H can provide 65536

More information

bolts: G Cr-1/5Mo (A193 B7) 16 x M20 (EN ISO 4014) MPR GASKET 'SP' PETRO 4,0mm 363 x 323 x 4,5 mm (2 pieces)

bolts: G Cr-1/5Mo (A193 B7) 16 x M20 (EN ISO 4014) MPR GASKET 'SP' PETRO 4,0mm 363 x 323 x 4,5 mm (2 pieces) test condition: 20 C 44 bar load condition 1: 206 C 18 bar load condition 2: 210 C 26 bar bolts: G41400 1Cr-1/5Mo (A193 B7) 16 x M20 (EN ISO 4014) gasket: MPR GASKET 'SP' PETRO 4,0mm 363 x 323 x 4,5 mm

More information

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

5/16 Flange nut. Bolt Keeper Plate (8 Sq. SYS.) (3) 1/2 x 3 Hex head connector zinc plated bolt w/ washers and nut. Anchor 3 sq. 7 Ga. 2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc

More information

PO Box 1879, 515 Tucker Ave. Friday Harbor, WA Phone: (360) Fax: (360)

PO Box 1879, 515 Tucker Ave. Friday Harbor, WA Phone: (360) Fax: (360) Thermocouple Replacement The thermocouple in your RADAK furnace has been made, installed, and inspected with great care. The junction, which is formed by spot-welding, is subject to failure due to mechanical

More information

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS Online data sheet FFUS15-1N1IO FFU A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Measurement principle Medium Ordering information Other models and accessories

More information

INSTALLATION INSTRUCTIONS for INSIGHT FIBER OPTIC FLAME SCANNERS

INSTALLATION INSTRUCTIONS for INSIGHT FIBER OPTIC FLAME SCANNERS CU-101 JUNE 2, 2009 INSTALLATION INSTRUCTIONS for INSIGHT FIBER OPTIC FLAME SCANNERS APPLICATION The FIREYE fiber optic scanners have been designed for installation on burners where movable vanes, air

More information

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL Main Features - Compact and heavy-duty industrial model - Interface: Bit-parallel, push pull ΠShort circuit proof - Housing: 58 mm - Shaft: 6 or 10 mm - Resolution: Max. 25 Bit =,554,42 steps over 4,096

More information

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160 Mechatronic pressure measurement Absolute pressure gauge with output signal For the process industry Models APGT43.100 and APGT43.160, NS 100 and 160 k Applications for further approvals see page 4 WIKA

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Profibus-PA. Profibus-PA. Process Automation. Over-Molded Cables Receptacles Field Wireables Accessories. UL File #: E

Profibus-PA. Profibus-PA. Process Automation. Over-Molded Cables Receptacles Field Wireables Accessories. UL File #: E Profibus-PA Process Automation Over-Molded Cables Receptacles Field Wireables Accessories U File #: E9 PROFIBUS (Process Field Bus) is a standard for field bus communication in automation technology. The

More information

SERVO INDEXING AT MECHANICAL INDEXER PRICES

SERVO INDEXING AT MECHANICAL INDEXER PRICES SERVO INDEXING AT MECHANICAL INDEXER PRICES 1 Servo indexing at mechanical indexer prices The EZ INDEXER servo indexers are high precision indexing machines designed to be low cost without sacrificing

More information

Dehydrator Box Build Plan

Dehydrator Box Build Plan Dehydrator Box Build Plan Cut Sheet Metal 1. Using a foot shear or similar tool, cut all the sheet metal components to the correct dimensions. For dimensions, refer to drawings LS-101F (Top/Side Panel)

More information

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids Ultrasonic Level Transmitter for Liquids and Solids measuring monitoring analyzing 4 Measuring Ranges: Liquids: Up to 25 meters (80 feet) Solids: Up to 10 meters (32 feet) Accuracy: ± 0.2 % of Reading

More information

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

Incremental encoders With blind or through hollow shaft pulses per revolution programmable Features Size mm Precise optical sensing Output signal level programmable (TTL or HTL) Blind or through hollow shaft, ø8 15 mm Connection axial, radial or tangential Pulses per revolution 1...65536, programmable

More information

PWB encoders GmbH Am Goldberg 2 D-99817 Eisenach Germany Phone: +49 3691 72580-0 Fax: +49 3691 72580-29 info@pwb-encoders.com www.pwb-encoders.com 1 of 9 Description The ME22 is a reliable low cost optical

More information

TECHNICAL DATASHEET Incremental Encoder RI 30

TECHNICAL DATASHEET Incremental Encoder RI 30 Miniature encoder for industrial use Low current consumption High noise interference immunity Cable lengths of up to 00 m Suitable for high pulse frequencies High protection class Applications: CNC machines,

More information

PIONEER TRADING CO., LTD.

PIONEER TRADING CO., LTD. PRECISION KURODA LTD. OIL COUNTRY GAUGES API THREAD GAUGES PREMIUM CONNECTION GAUGES THREAD MEASURING INSTRUMENTS CONTACT TO: PIONEER TRADING CO., LTD. 4-1 Kuzuha-Asahi 3-Chome Hirakata Osaka 573-1111,

More information