Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Size: px
Start display at page:

Download "Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions..."

Transcription

1

2 Flow meter Content F2-UN Description... 3 Technical data... 4 Dimension drawings... Operation... 8 Mounting instructions... 9 Order code F1-FP Description Technical Data Dimension drawings Order code F2-GF-TMS 300 Description... 1 Technical data Dimension drawings Order code F2-GF-TMS 00 Description Technical Data Dimension drawings Order code... 22

3 Flow meter volumes of conductive and nonconductive liquids. Swimming against the current requires more strength than with the current this is the simple fact on according to the phase difference process is based. The device has a compact design, and its wide range of possible applications means it can also be used in restricted spaces. The seal-free sensor design, with high-quality polysulfone (Ultrason S) combined with enclosure rating IP 67, not only makes it possible to use the device in harsh ambient conditions, but also guarantees high process reliability. The large text display also helps ensure simple, fast and problem-free commissioning. Flow sensor for conductive and nonconductive liquids No moving parts, compact design Process temperature up to 80 C, process pressure up to 10 bar High chemical resistance thanks to seal-free sensor design Large display with membrane keyboard Integrated teaching tube detection and conformance with FDA), CIP capable Adjustable measuring ranges, reduced number of variants Can be used fewer variants and lower storage costs Straight measuring tube reduces pressure loss, thus Sensor without seals increases process reliability and availability for all industries liquids compact design display easy-to-use up to 10 bar pressure closed operating interface.... page

4 Features Measuring principle Ultrasonic sensor Medium Fluids Nominal width measuring tube NW 10 / NW 1 / NW 20 / NW 2 Process temperature 0 C C Process pressure NW 10 und NW 1: Max. 10 bar / NW 20 und NW 2: Max. 6 bar EHEDG approval yes Performance NW10: 0.3 l/min NW1: 0.9 l/min NW20: 3. l/min NW2: l/min NW10: 21 l/min NW1: 36 l/min 6 NW20: 0 l/min NW2: 240 l/min Inlet zone NW10: 10 cm NW1: 30 cm NW20: 0 cm NW2: 80 cm Outlet zone NW10: 0 cm NW1: cm NW20: 10 cm NW2: 20 cm Conductivity No limitation Accuracy Reproducibility 0. % Resolution Mechanics Process connection: Wetted parts Housing material Weight Electronics NW 10 NW 1 NW 20 NW 2 PSU PSU G 1 / 2 G 3 / 4 G 1 G 1 1 / 4 1 / 2 NPT 3 / 4 NPT 1 NPT 1 1 / 4 NPT Clamp Clamp Clamp Clamp Supply voltage 1) 18 V DC V DC Ripple 2) Power consumption 3) Initialization time Protection class III Electrical connection, -pin /, 8-pin (depending on type) Electronics see order code Impuls/frequency output 0 khz khz Signal voltage Output current < 100 ma Load Response time 4) Enclosure rating IP 67 Output load < 00 Ohm Signal level Ambient data Ambient temperature 1) All connections are polarity protected. All outputs are overload and short-circuit protected. 2) May not exceed or fall short of VS tolerances. 3) Without load. 4) Analog output and display. 1 L 2 Q 3 4 Q 1 L 2 Q 3 4 Q2 Q 6 7 8

5 NW 10, process connection G 1/2 NW 1, process connection G 3/4 G 1/2 G 1/ (3.27) G 3/4 G 3/4.3 (3.32) 147 (.79) 12 (0.47) 147 (.79) 13.2 (0.2) All dimensions in mm (inch) All dimensions in mm (inch) NW 20, process connection G 1 NW 2, process connection G 1 1/4 G 1 G (3.70) G 1 1/4 G 1 1/ (3.88) 160 (6.30) 16.6 (0.6) 168 (6.61) 21 (0.83) All dimensions in mm (inch) All dimensions in mm (inch)

6 NW 10, Clamp (DIN ) NW 1, Clamp (DIN ) 34 (1.34) 34 (1.34) Clamp (DIN ) DN (3.74) 34 ( 1.34) 34 (1.34) Clamp (DIN ) DN (3.74) 149 (.87) 17 (0.67) 149 (.87) 17 (0.67) Dimensions in mm (inch) All dimensions in mm (inch) NW 20, Clamp (DIN ) NW 2, Clamp (DIN ) 0. ( 1.99) 0. ( 1.99) Clamp (DIN ) DN (4.0) 0. ( 1.99) 0. ( 1.99) Clamp (DIN ) DN (4.0) 162 (6.34) 2.2 (0.99) 170 (6.69) 2.2 (0.99) All dimensions in mm (inch) All dimensions in mm (inch)

7 NW 10, 1/2 NPT NW 1, 3/4 NPT 1/2" NPT 1/2" NPT 83.1 (3.27) 3/4" NPT 3/4" NPT.4 (3.32) 147 (.79) 12 (0.47) 147 (.79) 13.3 (0.2) All dimensions in mm (inch) All dimensions in mm (inch) NW 20, 1 NPT NW 2, 1 1/4 NPT 1" NPT 1" NPT 94.4 (3.72) 1 1/4" NPT 1 1/4" NPT 98.9 (3.89) 160 (6.30) 16.8 (0.66) 168 (6.61) 21.3 (0.) All dimensions in mm (inch) All dimensions in mm(inch)

8

9 Inlet and outlet paths

10 construction UN Tube size Sensor material 1 PSU black G1 N1 C1 Process connector Pipe thread G acc. to ISO 228 (Standard) Thread NPT Clamp (DIN ) BKS form A I0 SR Elektronik Current output, 1 transmitter output,, -pin (Standard) Current output, 2 transmitter output, 1 signal input,, 8-pin Bestellschlüssel UN 1

11

12

13

14

15

16

17

18

19

20

21

22

23

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS Online data sheet FFUS15-1N1IO FFU A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Measurement principle Medium Ordering information Other models and accessories

More information

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution P R o D u c T I n F o R m at I o n TDR Level Sensor The clean solution Level sensors The clean solution Product description The is a hygienic level sensor for liquids using TDR technology a process for

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350 Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350 Technical brochure Features Designed for use in severe maritime environments For medium and ambient temperatures

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Condumax CLS21 and CLS21D

Condumax CLS21 and CLS21D Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:

More information

Technical Information Condumax CLS21D/CLS21

Technical Information Condumax CLS21D/CLS21 TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application

More information

FLOWave SAW-Flowmeter

FLOWave SAW-Flowmeter SAW-Flowmeter No parts in the measurement tube 28-04 Conform to hygienic requirements Ideal for low conductivity or non conductive liquids Digital communication Type 8098 can be combined with... Compact,

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

Electronic Temperature Transmitters

Electronic Temperature Transmitters Electronic Temperature Transmitters ELECTRONIC TEMPERATURE TRANSMITTERS As with the pressure transmitters, HYDAC ELECTRONIC also has temperature transmitters appropriate for every application. The transmitters

More information

Technical Information Condumax CLS15D/CLS15

Technical Information Condumax CLS15D/CLS15 TI0009C/07/EN/4.4 7268306 Products Solutions Services Technical Information Condumax CLS5D/CLS5 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 0.0 cm or k = 0. cm Application

More information

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Pressure measurement PBMR Fully welded pressure transmitter for railway applications Fully welded pressure transmitter for railway Product highlights Ecellent accuracy and long term stability up to % FS Active temperature compensation over the entire operating temperature range Sensor

More information

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable

More information

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter Data Sheet DS/FCB300/FCH300-EN Rev. H CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter 4-wire compact device For flow measurement of liquids and gases Measurement made easy CoriolisMaster

More information

OPTIMASS 1000 Technical Datasheet

OPTIMASS 1000 Technical Datasheet OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Pressure transmitter For sanitary applications Model SA-11

Pressure transmitter For sanitary applications Model SA-11 Electronic pressure measurement Pressure transmitter For sanitary applications Model SA-11 WIKA data sheet PE 81.80 for further approvals see page 8 Applications For gases, compressed air, vapour, liquids,

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring

More information

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

Condumax CLS21 and CLS21D

Condumax CLS21 and CLS21D Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:

More information

M-2111 Series Ultrasonic Flow Meter

M-2111 Series Ultrasonic Flow Meter M-2111 Series Ultrasonic Flow Meter High Accuracy/Non-contact Flow Sensing in PFA Key Features Accuracy ± 1% of reading Repeatability ± 0.5% of reading All wetted parts made of New PFA (AP- 211SH) Contamination

More information

Mass Flowmeter CoriolisMaster FCM2000

Mass Flowmeter CoriolisMaster FCM2000 Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Pressure transmitters SPTW

Pressure transmitters SPTW Product range overview Method of measurement Pressure measuring range [bar] Measured variable Pneumatic connection Operating voltage Electrical connection [V DC] Piezoresistive pressure sensor Thin-film

More information

Mass Flowmeter CoriolisMaster FCM2000

Mass Flowmeter CoriolisMaster FCM2000 Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving

More information

High-quality pressure transmitter For general industrial applications Model S-10

High-quality pressure transmitter For general industrial applications Model S-10 Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-10 WIKA data sheet PE 81.01 for further approvals see page 4 Applications Machine building

More information

Your Global Automation Partner. PT2000 Pressure Transmitter

Your Global Automation Partner. PT2000 Pressure Transmitter Your Global Automation Partner PT000 Pressure Transmitter PT000 Pressure Transmitters Solution for demanding pressure measurements Turck's PT000 pressure transmitters offer an ideal solution for demanding

More information

Condumax W CLS15 and CLS15D

Condumax W CLS15 and CLS15D Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/01.12 71195835 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application The compact measuring

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES. SENSORS FOR FOOD AND LIFE SCIENCES. Product Information TSM and TSB FOOD Temperature Sensor Application/Specified usage Temperature Measurement in vessels and pipes Authorizations Application examples

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications 2- or 4-electrode technology Extended measuring range 0.05 S/cm... 500 ms/cm Process connections, materials, surface finish designed for use in hygienic applications

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

Screw-in resistance thermometers with terminal head Form B

Screw-in resistance thermometers with terminal head Form B Data Sheet 90.2002 Page 1/7 Screw-in resistance thermometers with terminal head Form B for temperatures from -50 to +600 C with replaceable measuring insert as single or twin resistance thermometer terminal

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

OPTITEMP. Compact sensors

OPTITEMP. Compact sensors OPTITEMP Compact sensors High process accuracy thanks to great long-term stability, quick response time and high measuring accuracy High reliability due to the robust design Small form factor, suitable

More information

OEM pressure transmitter For mobile working machines Model MH-3

OEM pressure transmitter For mobile working machines Model MH-3 Electronic pressure measurement OEM pressure transmitter For mobile working machines Model MH-3 WIKA Data sheet PE 81.59 Applications Load monitoring Load moment limitation Hydraulic drive control Special

More information

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763) A Sensor Designed with the Customer Applications in Mind! High Accuracy The PS400 and PS500 provide an accuracy rating of ±0.5 percent of the full scale. Flexible Mounting Options Multiple threaded connections

More information

Magnetic Inductive Flow Sensor induq

Magnetic Inductive Flow Sensor induq Operating manual (Translation) Operating manual... page 1-16 Magnetic Inductive Flow Sensor induq Series VMZ SIKA Ba_VMZ_en 10/2014. Please keep this operating manual for future reference. If the device

More information

Technical Information Memosens CLS82D

Technical Information Memosens CLS82D TI01188C/07/EN/03.16 71318348 Products Solutions Services Technical Information Memosens CLS82D Hygienic conductivity sensors, digital with Memosens technology, cell constant k = 0.57 cm -1 Application

More information

Relative and absolute pressure transmitter type 528

Relative and absolute pressure transmitter type 528 Relative and absolute pressure transmitter type 528 The compact type 528 pressure transmitter is based upon the Huba Control developed and since over 20 years well proven ceramic technology. These transmitters

More information

Resistance thermometers for process technology

Resistance thermometers for process technology Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available

More information

V 12-2 Miniature photoelectric switches: innovations in M12 housings

V 12-2 Miniature photoelectric switches: innovations in M12 housings V - Photoelectric switches Photoelectric proximity switches Photoelectric reflex switches Through-beam photoelectric switches V - iniature photoelectric switches: innovations in housings The V - optic

More information

Electronic Vacuum Regulator. Standard Specifications. Model Voltage

Electronic Vacuum Regulator. Standard Specifications. Model Voltage Electronic Vacuum Regulator Series ITV9/9 Stepless control of vacuum in proportion to an electric signal Straight type Piping/Wiring Diagram (VDC, madc) Vacuum pump, Ejector ITV9 Right angle type Tank

More information

High-quality pressure transmitter For general industrial applications Model S-20

High-quality pressure transmitter For general industrial applications Model S-20 Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-20 WIKA data sheet PE 81.61 Applications Critical industrial applications Demanding applications

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

ABB FCB330 FCH350 Mass Flowmeter datasheet

ABB FCB330 FCH350 Mass Flowmeter datasheet ABB FCB330 FCH350 Mass Flowmeter datasheet http://www.manuallib.com/abb/fcb330-fch350-mass-flowmeter-datasheet.html State of the art transmitter Easy handling Data safety due to unique sensor memory concept

More information

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Applications Food and beverage industry Pharmaceutical industry Biotechnology industry Cosmetic industry Special Features Meets

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

Magnetic Inductive Flow Sensors induq. Series VMI

Magnetic Inductive Flow Sensors induq. Series VMI Magnetic Inductive Flow Sensors induq Series VMI Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

Condumax W CLS15 and CLS15D

Condumax W CLS15 and CLS15D Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16 Technical Information TI 7C//ae Conductivity Measuring Cells for High-Temperature Applications Two-electrode measuring sensors with fixed cable or connector version with integrated temperature sensor Cell

More information

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet Temposonics Magnetostrictive Linear Position Sensors GB-M / GB-T SSI Sensor element and electronics can be changed Flat & compact sensor electronics housing Electrical connection is freely rotatable MEASURING

More information

Operating Instructions for Microwave Level Switch. Model: LNM

Operating Instructions for Microwave Level Switch. Model: LNM Operating Instructions for Microwave Level Switch Model: LNM 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating Principle...4 6. Mechanical Connection...5

More information

Online data sheet VT12T-2P410 V12-2 CYLINDRICAL PHOTOELECTRIC SENSORS

Online data sheet VT12T-2P410 V12-2 CYLINDRICAL PHOTOELECTRIC SENSORS Online data sheet VTT-P0 V- A B C D E F Illustration may differ Ordering information Type Part no. VTT-P0 606 Other models and accessories www.sick.com/v- H I J K L M N O P Q R S T Detailed technical data

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

PHOTOELECTRIC SENSORS. Online data sheet

PHOTOELECTRIC SENSORS. Online data sheet Online data sheet A B C D E F Illustration may differ Ordering information Type Part no. WTB4SL-3P6V 0585 Other models and accessories www.sick.com/w4sl-3v H I J K L M N O P R S T Detailed technical data

More information

bks-3/ciu Extract from our online catalogue: Current to:

bks-3/ciu Extract from our online catalogue: Current to: Extract from our online catalogue: bks-3/ciu Current to: 2016-11-18 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de microsonic

More information

NGR. Guided Wave Radar Level Transmitter

NGR. Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter measuring monitoring analyzing NGR For Liquids Operates Independent of Density, Temperature, Pressure, Humidity, and Conductivity Standard Measuring Length: 6. Ft (Longer

More information

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) Electronic pressure measurement OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 Applications Hydraulics and pneumatics Pumps and compressors

More information

WATERFLUX 3070 Technical Datasheet

WATERFLUX 3070 Technical Datasheet WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone

More information

Electronic Pressure Switch Type MEP

Electronic Pressure Switch Type MEP MAKING MODERN LIVING POSSIBLE Data sheet Electronic Pressure Switch Type MEP MEP 2200 and MEP 2250 versions: Dual output Output : Switch output Hysteresis % FS Time constant ms Output 2: Analogue output

More information

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) Pressure OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 for further approvals see page 11 Applications Hydraulics and pneumatics Pumps and compressors

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module / - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect:

More information

Electronic temperature switch with display Model TSD-30

Electronic temperature switch with display Model TSD-30 Electrical temperature measurement Electronic temperature switch with display Model TSD-30 WIKA data sheet TE 67.03 Applications Machine tools Hydraulic power packs Coolant and lubrication systems Machine

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span 2-way motor valve Actuator isolated from flow path Excellent range and fast response times Low power consumption Orifice sizes 1 to 10 mm Versions: Standard, positioner, process controller and high pressure

More information

Magnetic Inductive Flow Sensors VMI Series

Magnetic Inductive Flow Sensors VMI Series Magnetic Inductive Flow Sensors VMI Series SIKA Dr.Siebert & Kühn GmbH & Co. KG Struthweg 7 9 34260 Kaufungen Germany.: +49 5605 803-0 Fax: +49 5605 803-54 e-mail: info@sika.net www.sika.net Magnetic Inductive

More information

Insertion Flow sensor for continuous flow measurement

Insertion Flow sensor for continuous flow measurement Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface

More information

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H Level measurement Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H KSR data sheet FLM-H Applications Food and beverage industry Pharmaceutical industry

More information

Series 10-ZSE30A(F)/10-ISE30A

Series 10-ZSE30A(F)/10-ISE30A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H

More information

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU Level probe Features Assembly Device for hydrostatic pressure measurement in liquids High resistance to overload High-precision, robust ceramic measuring cell with longterm stability Simultaneous level

More information

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm) Products Handheld Measuring Instruments Digital PIEZOVAC Sensor PV 101 Digital THERMOVAC Sensor TM 101 The digital compact PIEZOVAC PV 101 and THERMOVAC TM 101 combine high-quality sensor technology with

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Ship building Measurement and control technology

More information