ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Size: px
Start display at page:

Download "ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module"

Transcription

1 / - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect: Directly powered from the 80 panel or 80 wall Cost-effective solution for / - in solid matter-free liquids Fittings available for all standard hydraulic interfaces Can be upgraded to a low cost transmitter providing calibrated pulse output or 4-0 ma Approval Design The inline rotor flow sensor for continuous flow measurement is specially designed for use in neutral and aggressive, solid-free liquids. The sensor is made of a compact fitting and an electronic module quickly and easily connected by a bayonet. The Burkert designed plastic fitting system (PVC, PP, PVDF) ensures simple installation of the sensors into all pipes from / to. The sensor produces a frequency signal proportional to the flow which can easily be transmitted and processed ma output signal with transmitter module - Adjustable frequency output signal with pulse divider module - Direct connection to batch controller Type 8600 mounted on valve - Connection to separate versions of flow transmitter Type 80: Panel version Wall-mount version Applications Flow Measurement & Dosing Control Water treatment and process technology Cooling water monitoring Industrial waste water treatment Auxiliary plants Irrigation Ideal system solutions for pure water and chemical aggressive liquids Burkert Contromatic USA 60 McGaw Avenue Irvine, CA 964 Tel Fax Burkert Contromatic Inc. 760 Pacific Road, Unit 3 Oakville, Ontario, Canada L6L 6M Tel Fax Fluid Control Solutions

2 Design The flow sensor consists of a transducer (coil or Hall sensor) and an open-cell inline rotor directly connected to a compact fitting. In a or 3-wire system, the signal can be displayed or processed directly. The output signal is provided via a 4-pole cable plug according to DIN Principle of Operation When liquid flows through the pipe, the inline rotor is set in rotation producing a measuring signal in the transducer. The induced voltage is AC. The frequency and amplitude are proportional to the flow. The flow sensor 8030 with Hall sensor requires an external power supply of -30 VDC. The flow sensor 8030 with coil requires no external power supply. The flow sensor 8030 with 4-0 ma output requires an external power supply of -4 VDC. The flow sensor 8030 with adjustable frequency output requires an external power supply of -30 VDC. The sensor measures a flow rate from 0.3 ft/s (0. m/s). Installation The flow sensor is made of a compact fitting and an electronic module which can be quickly and easily connected by means of a Turn & Lock. to install wireless sensor to fitting The recommended In- and Outflow straight pipe length should equal 0xD in and 3xD out. According to the piping design, necessary distances can be longer or use a flow conditioner to obtain the best accuracy. For more information, please refer to EN ISO 67-. The flow sensor can be installed in either horizontal or vertical pipes. The suitable pipe size is selected using the diagram on the next page. Pressure and temperature ratings must be respected according to the selected fitting material (see next page). The flow sensor is not designed for gas flow measurement. Burkert "Turn & Lock"

3 Examples of Fitting Selection The suitable pipe size is selected using the diagram below. Example : Specification of nominal flow: Ideal flow velocity: Example : Specification of nominal flow: 0 m 3 /h Ideal flow velocity: 0 gpm 8 fps For these specifications, the diagram indicates a pipe size of -/. -3 m/s For these specifications, the diagram indicates a pipe size of DN 40. Pressure (bar) Pressure-Temperature Diagram PVC + PP PVDF PP (PN 0) Note: bar = 4. PSI Application range for complete device (fitting+transmitter) PVC (PN 0) Temperature ( o C) PVDF (PN 0) Diagram Flow / Pipe Size / Velocity Flow l/s l/min m 3 /h Flow gpm DN DN 40 DN 3 DN DN 0 DN " /" /4" " 3/4" /" m/s fps Flow velocity Flow velocity 3

4 Connection to Other Burkert Devices Type with Hall sensor Link: cable Type 80 Link: quick connection via cable plug socket Type 80 panel or wall-mount version Link: cable 8030 with Hall sensor low power Type 80 Link: quick connection via cable plug socket Type 803 Link: quick connection via cable plug socket 8030 with coil Type 80 wall-mount with battery power supply Link: cable 4

5 Technical data General data Pipe diameter From / to (DN to DN 0) Measuring range.0 fps to 3.8 fps (0.3 m/s to 0 m/s)* As from 0.9 gpm (/ pipe,.0 fps flow velocity) As from 3 l/min (DN pipe, 0.3 m/s flow velocity) Measuring error. With In-line calibration (Teach-In): ±0.% o.f.s. (at 3.8 f/s)(0 m/s)*. With standard mean K-factor: ± (0.% o.f.s. +.% o.r.)* Linearity Repeatability ±0.% o.f.s. (at 3.8 f/s)(0 m/s)* 0.4% o.r.* Fluid temperature maximum PVC: F (0 C); PP: 76 F (80 C); PVDF: F (00 C) Ambient temperature 3 F to 40 F (0 C to 60 C) Storage temperature 3 F to 40 F (0 C to 60 C) Pressure class 30 PSI (PN 0) % max. error % 0.% o.f.s. + o.f.s.. o.r. m/s Enclosure NEMA 4 Fitting Sensor holder Inline rotor Axis and bearing O-rings Housing Front plate foil PVC, PP, PVDF PVC, PP, PVDF PVDF Ceramic FPM (Viton) standard PC Polyester Specific Data for 8030 with Coil Can only be connected to flow transmitter Type 80 with battery power supply in wall-mount version Specific Data for 8030 with Hall Sensor Supply voltage -30 VDC Output signal Transistor PNP and NPN open collector maximum 00 ma frequency: 0-00 Hz Specific Data for 8030 with Hall Sensor Low Power (Can only be connected to separate versions of flow transmitter Type 80 and to 4-0 ma or calibrated frequency output modules Specific Data for 8030 with 4-0 ma Output Associated flow sensor Hall sensor low power Supply voltage -4 VDC Output signal 4-0 ma Load Max. 00Ω at V Max. 000Ω at 4 V Accuracy % Material of additional housing PA Specific Data for 8030 with Calibrated Frequency Output Associated flow sensor Hall sensors Supply voltage -30 VDC Output signal Transistor PNP and NPN open collector maximum 00 ma Accuracy 0.% Material of additional housing PA (*) In reference conditions (water, 68 F, ideal installation)

6 Operation and Display with 4-0 ma output module 4-0 ma module with control unit The operation is specified according to two levels: Indication in operating mode - Flow (digits and bargraph) Parameter definition - K-factor - Time unit ma measuring range The device works without the control unit. The control unit only enables performance by parameter definition. Amend values Confirm values with calibrated frequency output module The operation is specified according to the following level: Parameter definition - K-factor - Multiplicator D Rotary switches for K-factor selection Rotary switch for mutiplicator D selection 6

7 Dimensions [inch] True union with solvent/fusion spigot connections Dimensions [inch] Port DN Variable Dimensions [inch] Connection [inch (mm)] Ø D L L L3 H True union / () connection with 3/4 (0) solvent/fusion () spigot -/4 (3) / (40) (0) Dimensions [mm] Port Connection DN Variable Dimensions [mm ] Ø D L L L3 H True union connection with solvent/ fusion spigot Solvent joint/weld-end connections Dimensions [inch] Port DN Variable Dimensions [inch] Connection [inch (mm)] ød L L H PVC PP PVC PP PVDF PVDF Solvent joint or / () weld-end 3/4 (0) connection () /4 (3) / (40) (0) Dimensions [mm] Port DN Variable Dimensions [mm] Connection ød L L H PVC PP PVC PP PVDF PVDF Solvent joint or weld-end connection

8 Ordering Chart A complete System consists of two or three basic units as follows: -Fitting Type S030 which houses the inline rotor, -Sensor Electronic Type SE30, -Upgradable to a low-cost transmitter with calibrated pulse output or 4-0 ma output This can also be connected to a transmitter Type 803 in panel- or wall-mount version (see datasheet of Type 80 flow transmitter). Selection example: A System with 4-0 ma output for PVC pipe consists of: -Fitting Type S030 (True union with solvent spigot) U -Sensor Electronic Type SE30 (Hall sensor low power ) 43 9 L -4-0 ma output module Type V -Control unit for 4-0 ma output module Type X Ordering Chart Fittings Type S030 PVC Body Specifications / 3/4 -/4 -/ (DN ) (DN 0) (DN ) (DN 3) (DN40) (DN 0) True union connection with solvent spigot (Europe standard version) N P U R J K True union connection with solvent spigot (North America standard version)(npt) W 43 9 K 43 9 L M N 43 9 P Solvent joint connection L M N P Y Z PP Body Specifications / 3/4 -/4 -/ (DN ) (DN 0) (DN ) (DN 3) (DN 40) (DN 0) True union connection with fusion spigot Q R S T Y M Weld-end connection N P Q R J K PVDF Body Specifications / 3/4 -/4 -/ (DN ) (DN 0) (DN ) (DN 3) (DN 40) (DN 0) True union connection with fusion spigot U V S P Q R Weld-end connection J K L M W X Ordering Chart Sensor Electronics Type SE30 Specifications Power Cable Supply Entry Coil Sensor (only connectable to Type 80 wall-mount version with batteries) None DIN 4360 PG C Hall Sensor -30 VDC DIN 4360 PG D Hall Sensor low power (only connectable to Types 80, 80, and 803) from 80/803 DIN 4360 PG E Ordering Chart for Standard Output Signals Specifications Power Cable Supply Entry Calibrated pulse output module Type VDC x PG P 4-0 ma output module Type VDC x PG V Control unit for 4-0 ma output module Type VDC None X In case of special application requirements, please consult for advice. We reserve the right to make technical changes without notice. US_8030_Plastic_0/00 8

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

Insertion Flow sensor for continuous flow measurement

Insertion Flow sensor for continuous flow measurement Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Paddle wheel flow controller for On/Off control

Paddle wheel flow controller for On/Off control addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

FLOWave SAW-Flowmeter

FLOWave SAW-Flowmeter SAW-Flowmeter No parts in the measurement tube 28-04 Conform to hygienic requirements Ideal for low conductivity or non conductive liquids Digital communication Type 8098 can be combined with... Compact,

More information

Plug & Play. No Calibration Required

Plug & Play. No Calibration Required No Calibration Required Plug & Play No K-actor Programming Read the User's Manual Carefully before Starting to Use the Unit. All TK Series low Meters are actory Calibrated. Manufacturer reserves the right

More information

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y RA 9 /6.98 -Way Proportional Logic Cartridge Valve Model FE.. (Series X and X) Size 6... 6... 6 PSI (5 bar)... 75 GPM (8 L/min) RA 9 /6.98 Replaces: 5.9 Characteristics: Single land throttle valve (main

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

Universal process controller econtrol

Universal process controller econtrol 8 Universal process controller Type 8 can be combined with... Continuous, point, point and On/Off control Ratio control function Sensor inputs (,, frequency, RTD) Control of proportional, process and motor

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

OEM radar transmitter, for aggressive media level measurement

OEM radar transmitter, for aggressive media level measurement OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type

More information

DUK COMPACT ULTRASONIC FLOWMETER

DUK COMPACT ULTRASONIC FLOWMETER DUK COMPACT ULTRASONIC FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.0- GPM to 0.6-60 GPM Accuracy: ±. % of F.S. Turndown Ratio: 0: P max : 30 PSI; T max

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

prosonic T FMU230, FMU231

prosonic T FMU230, FMU231 Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters

More information

Universal process controller econtrol

Universal process controller econtrol Universal process controller Type 8611 can be combined with... Continuous, 2point, 3point and On/Off control Ratio control function Sensor inputs (,, frequency, RDT) Control of proportional, process and

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical

More information

Magnetic Inductive Flow Sensor induq

Magnetic Inductive Flow Sensor induq Operating manual (Translation) Operating manual... page 1-16 Magnetic Inductive Flow Sensor induq Series VMZ SIKA Ba_VMZ_en 10/2014. Please keep this operating manual for future reference. If the device

More information

Universal process controller econtrol

Universal process controller econtrol Universal process controller Type 8611 can be combined with... Continuous, 2point, 3point and On/Off control Ratio control function Sensor inputs (,, frequency, Pt100) Control of proportional, process

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS

More information

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

MaxxFlow HTC Flow Measurement for Dry Bulk Solids EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Flow Ranges from 0.18-7.8 GPH through 9-180 GPM For Use with a Wide Variety of Conductive Liquids,

More information

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016 J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow

More information

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Characteristics Applications System Evaluation connection Media pressure temperature

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B Rev012008 USER MANUAL DEI MODEL USFT-B USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER The Model USFT-B is an ultrasonic transit time flow meter designed to accurately and reliably report the flow

More information

Inductive conductivity transmitter JUMO CTI-Junior

Inductive conductivity transmitter JUMO CTI-Junior M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE: Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

Pressure Transmitter SIL

Pressure Transmitter SIL Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute

More information

Product Overview Sensors, Transmitters and Controllers

Product Overview Sensors, Transmitters and Controllers SOLENOID VALVES PROCESS VALVES PNEUMATICS MICROFLUIDICS MASS FLOW CONTROLLERS SOLENOID CONTROL VALVES Bürkert Fluid Control Systems Christian-Bürkert-Straße 13-17 74653 Ingelfingen Germany Tel. +49 (0)

More information

M1 series 2 way ball valve with integrated Praher Labeling System

M1 series 2 way ball valve with integrated Praher Labeling System General: Material: PVC-U Seal material: EPDM / FPM Ball seating joint: PTFE Dimensions: DN10 DN50 d16 d63 d3/8 d2 Connection types: Solvent socket DIN / ASTM / JIS Solvent spigot DIN Threaded socket BSP

More information

BPF8020. Insertion Paddle Wheel Flowmeter

BPF8020. Insertion Paddle Wheel Flowmeter BPF8020 Insertion Paddle Wheel Flowmeter Continuous Flow Measurement Operating Range 0.3 10 m/s Pipe Diameter DN20 DN200 Repeatability of ± 0.4% of Reading Description The paddle wheel flowmeter for continuous

More information

Ultrasonic level measuring device, non-contact

Ultrasonic level measuring device, non-contact Ultrasonic level measuring device, non-contact For level measurement up to 8 m 4... 20 ma/hart - 2 wires Suitable for solids ATEX approvals Type 8177 can be combined with... Type 8611 Type 8793 Type 8802-GB

More information

Product Overview Sensors, Transmitters and Controllers

Product Overview Sensors, Transmitters and Controllers Product Overview Sensors, Transmitters and Controllers SOLENOID VALVES 01 PROCESS VALVES 894498 Version 11/2015 Print 11/2015 Bürkert Fluid Control Systems Christian-Bürkert-Straße 13-17 74653 Ingelfingen

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Magnetic Inductive Flow Sensors induq. Series VMI

Magnetic Inductive Flow Sensors induq. Series VMI Magnetic Inductive Flow Sensors induq Series VMI Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

DVZ COMPACT VORTEX FLOWMETER

DVZ COMPACT VORTEX FLOWMETER DVZ COMPACT VORTEX FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.13-1.2 GPM to 2.7-26 GPM Accuracy: ±2.5 % of F.S. Vortex Shedding Technology with No Moving

More information

SM-15. Features. Plastic Flowmeters as per the Variable Area Principle. Description: Application:

SM-15. Features. Plastic Flowmeters as per the Variable Area Principle. Description: Application: / Flow / Variable Area SM-5 Plastic Flowmeters as per the Variable Area Principle Description: Features / For every industrial application / For fluid and gaseous media / Simple and robust design with

More information

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

Introducing GPI s Latest

Introducing GPI s Latest Introducing GPI s Latest Electronic Digital Meter GREAT PLAINS INDUSTRIES, INC. WICHITA, KANSAS CALIBRATE DISPLAY MODEL NON-COMMERCIAL GM SERIES FLOWMETER Total Reset Total New Lockout Feature Lockout

More information

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite KFS Flap Flow Meter KFS suitable for H, acids, alkalis and gases spring-loaded horizontal or vertical flow direction low pressure loss mainly viscosity independent optional threshold value contacts optional

More information

Ambient Conditions. Operating Conditions. Pressure

Ambient Conditions. Operating Conditions. Pressure Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version

More information

NAT Applications. Features

NAT Applications. Features NAT 85 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The industrial

More information

FMG90 Series Electromagnetic Flow Meter

FMG90 Series Electromagnetic Flow Meter . FMG90 Series Electromagnetic Flow Meter - 2 - Series FMG90 Series FMG90 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Delivery, unpacking and accessories...

More information

Process Control Calibration Made Easy with Agilent U1401A

Process Control Calibration Made Easy with Agilent U1401A Process Control Calibration Made Easy with Agilent U1401A Application Note This application note explains how the Agilent U1401A with simultaneous source and measure functions eases technicians calibration

More information

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS Rev04009 USER MANUAL DEI MODEL USFT-CS USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER The Model USFT-CS is an ultrasonic transit time flow meter designed to accurately and reliably report the flow

More information

Convex Strainers DN PN 80, 100, 200

Convex Strainers DN PN 80, 100, 200 55 Convex Strainers DN 400-1000 PN 80, 100, 200 Designed for protection of compressor rotor bundle against foreign-object damage. Working medium is non-aggressive natural gas and other non-aggressive media

More information

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

DVZ. Vortex Flowmeter Compact. for low viscosity liquids Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0. -4. 0-00 L/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼...G, ¼" NPT..." NPT

More information

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

Lowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL.

Lowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL. Centrifugal pumps with open impeller and flanged connections SHO Series MARKET SECTORS CIVIL, INDUSTRIAL. APPLICATIONS Industrial washing machines. Commercial dishwashers. Washing of metal parts, surface

More information

1) What meter do I need in this application?

1) What meter do I need in this application? ELECTRONIC ELECTRONIC Choices 1) What meter do I need in this application? Meter choice is determined by: Level of accuracy required, flowrate, line size, viscosity, fitting type, pressure rating, temperature,

More information

NAT Applications. Features

NAT Applications. Features NAT 85 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The industrial

More information

Proportional Directional Control Valves Nominal sizes 16 and 25

Proportional Directional Control Valves Nominal sizes 16 and 25 Proportional Directional Control Valves Nominal sizes 16 and 25 Pilot operated, electrically adjustable Interface acc. to DIN 24 340 and ISO 4401 PN [p max. ] = 315 bar 7502968.06.01.06 Description Design

More information

Specification DataFile

Specification DataFile DATUM U & U Ultrasonic Level System Specification DataFile 6-digit backlit l.c.d. and bargraph clear display of measured level Echo Processing using 'DATEM' software true level measurement, overcoming

More information

DUK. Compact Ultrasonic Flowmeter

DUK. Compact Ultrasonic Flowmeter Compact Ultrasonic Flowmeter measuring monitoring analyzing DUK Measuring Ranges: 0.0... GPM to 0.6...60 GPM Accuracy: ±0.7 % of Reading + ±0.7% of F.S. Turndown Ratio: 0: P max : 30 PSI; T max : 48 F

More information

OPTIMASS 1000 Technical Datasheet

OPTIMASS 1000 Technical Datasheet OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

ULTRASONIC FLOW METER FT101

ULTRASONIC FLOW METER FT101 Introduction F t101 is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp on type ultrasonic flowmeter is easy to install and no need to cut off the pipe, that

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,

More information

Technical Information Nivector FTC968, FTC968Z

Technical Information Nivector FTC968, FTC968Z TI0007F/00/EN/7.6 7494 Products Solutions Services Technical Information Nivector FTC968, FTC968Z Capacitance Point level switch for powder and fine-grained bulk solids Application The Nivector is a small-sized

More information

Bulb ph and ORP Electrodes

Bulb ph and ORP Electrodes Bulb ph and ORP Electrodes Type: PH200C, PH200 CS, PH222 CD, PH223 CD, PH635 CD, ORP500 C, ORP500 CS, ORP222 CD, Main Features Epoxy or glass body. Single or double junction technology. Large gel reference

More information

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C. Vane Flow Meter, Monitor, Counter, Batching System in modular design for liquids measuring monitoring analysing DF S 4 O O Measuring ranges: 0.08-0.50... 40-160 l/min water OO Measuring accuracy: ± 2.5%

More information

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version Mechatronic temperature measurement Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version WIKA data sheet TV 17.01 for further approvals see page 6 Applications

More information

Measuring and Controlling Unit Multronic OC

Measuring and Controlling Unit Multronic OC Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously

More information

EN-2018 MAGNETIC FLOW METERS

EN-2018 MAGNETIC FLOW METERS EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance

More information

4/3 Proportional Directional Valve, Size SAE 10

4/3 Proportional Directional Valve, Size SAE 10 / Proportional Directional Valve, Size SAE Q max =. gpm [ l/min], p max = psi [ bar] Direct acting, sliding-spool design, with solenoid operation Series PDFC- Description Series PDFC proportional directional

More information

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution P R o D u c T I n F o R m at I o n TDR Level Sensor The clean solution Level sensors The clean solution Product description The is a hygienic level sensor for liquids using TDR technology a process for

More information

NGR. Guided Wave Radar Level Transmitter

NGR. Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter measuring monitoring analyzing NGR For Liquids Operates Independent of Density, Temperature, Pressure, Humidity, and Conductivity Standard Measuring Length: 6. Ft (Longer

More information

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions... Flow meter Content F2-UN Description... 3 Technical data... 4 Dimension drawings... Operation... 8 Mounting instructions... 9 Order code... 10 F1-FP Description... 11 Technical Data... 12 Dimension drawings...

More information