WDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system
|
|
- Nora Morris
- 5 years ago
- Views:
Transcription
1 CONDUCTIVITY TRANSMITTR WDM-A (-wire type) WDM-6A (-wire type) It is a type of small firm aluminum -electrode site-installation CONDUCTIVITY TRANSMITTR (signal transmitter) and easy operate. The device is divided in -wire type (V DC power supply) and -wire type (free power supply AC), and the transmission output is 0mA DC. Please additionally refer the detailed specification of conductivity meter detecr for the details. Functions Features Large measurement range It has large measurement range from ultrapure water (0 0.μS/cm) plant drainage (0 0mS/cm) and large temperature compensation range of - 0 C. according the cell constant of detecr, the following measurement range is available for selection. 0/ cm (note ) Measurement range (note ) Changeable measurement range As shown in the table above, the cell constants are changeable in 0 types of measurement range. For example, if the cell constant is 0./cm, it can be changed between 0.00μS/cm and μS/cm. Temperature display The measured sample water temperature (- 0 C) is displayed. Measured value adjustment The measured value can be adjusted based on the conductivity value of secondary standard meter, etc. (Adjustment extent ±0% of measured value). Self-diagnosis Aumatic recovery measuring mode If the maintenance mode lasts for hours, the measuring mode will be recovered aumatically. Unit (note ) (Note ) quivalent value (Note ) S/m unit system can be also made. (Note ) If the cell constant is 0/cm high conductivity, it is recommended use the electromagnetic induction type conductivity meter with better stability. Structure diagram Converr WDM - A type -wire system Detecr <Instrument room> Power transmission output (V DC 0mA) Distribution board C- 0 type 0m A6 type <Site> Receiver DC power supply Indicar Recorder Regular DCS, etc. AR type Converr WDM -6A type -wire system <Site> <Instrument room> Detecr C- 0 type Transmission output ( 0mA DC) Receiver 0m A6 type AR type Instrument power supply 00 0V AC or 00 0V AC Indicar Recorder Regular DCS, etc.
2 Standard specification Product name Model Measuring method CONDUCTIVITY TRANSMITTR WDM-6A (-wire type) WDM-A (-wire type) AC -electrode method Min. 0 0.μS/cm Max. 0 0mS/cm Measurment range Or Min. 0 0 μs/m Max mS/m (Temperature - 0 C, only displayed, no transmission output) Display method -bit electronic LCD Compensation range - 0 C Conversion temperature C Temperature compensation Temperature characeristic Conductivity temperature characteristic of NaCl solution Accuracy within ±.0%FS (equivalent power) Linearity Performance Within ±0.%FS (equivalent input) Repeatability Transmission output Within ±0.%FS (equivalent input) 0m A DC insulating type resistive load less than 60Ω Power supply Power consumption V±0% DC Less than 0.6VA 90 V AC or 80 6V 0/60Hz AC About VA Ambient temperature humidity Structure -0 C, less than 99% (RH) (but no condensation) Outdoor installation, IP (dust proof type, shunt preventing type) Overall dimensions 8 (W) 9 (H) 78 (D) mm Installation method Weight 0A pipe is used About kg Wiring interface Main body Materials positions of G ¾ (PF ¾F) Aluminum alloy casting Observation window Resin Assembly part Coating color SUS 0 Metal silver and blue Terminal diagram Operation switch display position WDM-A type (-wire type) Digital meter 0 Grounding terminal Mode switch Carl switch Standby switch Standard (NAS) measuring mode Standby (ST-BY) maintenance mode Power transmission cable WDM-6A type (-wire type) Main display part The device will be aumatically started after being powered on for several seconds, and all lights will be on for testing. Standby symbol Wait symbol Temperature unit Grounding terminal Unit Display position Main Display Position Transmission output cable Power cable
3 Outline dimensions Unit mm Display position WDM-A type (-wire type) 78 Assembly part (0A pipe is used) (The installing support can be changed left and right) Power supply transmission cable wiring interface G/ (PF/) φ, cable filler attached wiring interface G/ (PF/) 6 WDM-6A type (-wire type) Assembly part (0A pipe is used) (Assembly part can be changed left and right) Power cable wiring interface G/ (PF/F) (φ, cable filler attached) Transmission output cable wiring interface G/ (PF/), φ, cable filler attached wiring interface G/ (PF/) Hood (optional) Materials Installation method Code No. SUS0 Installed on the 0A pipe 9K 0 Installed outdoors; recommended be used in case of exposure direct sunlight.
4 -wire line connection diagram Detecr WDM-A model Converr Power transmission output ( 0mA DC) 0 D type D type Receiver (Less than 60Ω) V DC DC power supply -wire line connection diagram Detecr WDM-6A type Converr AC power supply 9 Transmission output ( 0mA DC) D type D type Receiver (less than 60Ω)
5 Product code *. and Measurement range 0.0/cm (Please specify the measurement range from the table below) 0./cm (Please specify the measurement range from the table below).0/cm (Please specify the measurement range from the table below) cm unit system above 0.0/cm (Please specify the measurement range from the table below) m unit system below.0/m (Please specify the measurement range from the table below) 0.0/m (Please specify the measurement range from the table below) 00/m (Please specify the measurement range from the table below) 000/m (Please specify the measurement range from the table below) Surface working (coating) * Standard coating Heavy corrosion preventing coating Built-in surge arrester* No Yes Wiring interface adapr integration No G¾ (PF¾) standard G½ (PF½) SU0 NPT½ SUS0 NPT¾ SUS0 Hood or not (sunshade) No Yes (code No.9K) Mark form Japanese Designated nglish Combined detecr No* Making simultaneously Please select the test range of designated S/cm unit system from the table below. (Not made except for the specifications below) Measurement range (unit S/cm, displayed in the LCD) *. Please select the test range of designated S/cm unit system from the table below. (Not made except for the specifications below) Measurement range (unit S/m is displayed at the sealing part) *. The standard coating method is spray melamine resin up and down with the average film thickness of more than 0μm. The heavy corrosion preventing coating method is spray epoxy resin at the middle and lower parts and spray polyurethane resin at upper part with the film thickness of more than 00 μm. *. The porcelain surge arresr (simple type) is installed on the power transmission line. *. In case of " No. " please notify the length of cable installed.
6 Product code cm unit system above m unit system below *. Supply voltage AC 90V~V 0/60Hz 80V~6V 0/60Hz AC and measurement range 0.0/cm (Please specify the measurement range from the table below) 0./cm (Please specify the measurement range from the table below).0/cm (Please specify the measurement range from the table below) 0.0/cm (Please specify the measurement range from the table below).0/m (Please specify the measurement range from the table below) 0.0/m (Please specify the measurement range from the table below) 00/m (Please specify the measurement range from the table below) 000/m (Please specify the measurement range from the table below) Surface working (coating) * Standard coating Heavy corrosion preventing coating Built-in surge arresr* No Yes Wiring interface adapr integration No G¾ (PF¾) standard G½ (PF½) SU0 NPT½ SUS0 NPT¾ SUS0 Hood (sun shade) No Yes (code No. 9K) Mark form Japanese Designated nglish Combined detecr No* Making simultaneously Please select the test range of designated S/cm unit system from the table below. (Not made except for the specifications below) Measurement display range (unit S/cm, displayed in the LCD) *. Please select the test range of designated S/cm unit system from the table below. (Not made except for the specifications below) Measurement display range (unit S/m is displayed at the sealing part) *. The standard coating method is spray melamine resin up and down with the average film thickness of more than 0μm. The heavy corrosion preventing coating method is spray epoxy resin at the middle and lower parts and spray polyurethane resin at upper part with the film thickness of more than 00 μm. *. The porcelain surge arresr (simple type) is installed on the power transmission line. *. In case of no, please notify the length of cable installed.
7 Sample Conditions Temperature 0~00 C Typical Combination Detecrs Pressure max. MPa max. 0. MPa for AR type Product Name Conductivity Detecr Model Materials A6 cell, AR cell Main body SUS 6 Titanium for AR cell Cell Constant A6 cell...0.0/cm,0./cm,.0/cm AR cell (Compact, For Pure Water)...0./cm Temperature Sensor Thermisr type (enclosed in inner pole) lectrode Insulation glass, PTF FKM,PPS for AR cell Connecr box cast aluminum Case SUS 6 or polypropylene (PP) Piping Connections R/ thread or Flange C-0 type (OD φ8) Thread type 0 A6- type A6- type A6- type Wiring interface AR- type Assembly screw 7 0 Minimum liquid level Water-proof connecr Opposite side 9 hexagon Rc 0 7 R 0 Shell Connecr box lectrode position lectrode position Connecr box Shell type Flange type A6- type A6- type A6- type 0 Wiring interface Connecr box A6- type A6- type A6- type Wiring interface Sample outlet 60 Minimum liquid level lectrode position Sample inlet The dedicated cable is used for conductivity meter between the transmitter and detecr Model Outer diameter Insulating matter xternal coverage Insulating resistance between cores xtended distance Standard length Weight C-0 φ8 PP and plastic Plastic more than 0MΩ/00m Conducr (0.mm) Mixing Adhesive tape pasting Sealing PVC outer coverage PP insular (blue) Max. 0 m, not available connect in the middle. m 0m, in unit of m about 0.kg/m PP insular (natural color) Semi-conductive PVC Sealing PT adhesive tape PP outer coverage (black) Conducr (0.mm) PP insular (green) PP insular (red) C-0model Sectional view
8 Relevant equipment Prepare the power supply for -wire converr. Please order as per the demand. Power supply PA- Model + Rated output voltage V- V DC Rated output current ma ( meters cannot be connected in parallel) Supply voltage 00V±0% 0/60Hz AC Ambient temperature - C for indoor application, insertion type Structure Weight about 00 g General lerance ±mm V output Transmission output (-, +) (Mounting hole) Terminal block transmission output signal; 0mA DC can be acquired. Power supply (7, 8) CAUTION arth () Please read the operation manual carefully before using producuts. Overseas Sales Division DKK-TOA Corporation 9-0, -Chome, Takadanobaba, Shinjuku-ku, Tokyo Japan Tel Fax http// Information and specifications are subject change without notice. Issued on //08
Dissolved Oxygen Transmitter
Dissolved Oxygen Transmitter OBM-67H The OBM-67H is a -wire type (4VDC power supply) dissolved oxygen transmitter housed in a robust, die-cast aluminum enclosure suitable for installation out in the field.
More informationSPECIFICATION SHEET. 2-WIRE TYPE ph ANALYZER/TRANSMITTER SYSTEM CONFIGURATION
ISO-14001 ISO-9001 SPECIFICATION SHEET 2-WIRE TYPE ph ANALYZER/TRANSMITTER Model: HDM-135A FEATURES 2-wire ph transmitter with built-in microcomputer: Field installation type ph analyzer / transmitter
More informationIndustrial Conductivity (Electric Conductivity) Detector
Industrial Conductivity (Electric Conductivity) Detector / (General Multi-Purpose Use) R/R (Compact Ultra-Pure Water Use) S (Intrinsically Safe) The -electrode type industrial conductivity (electric conductivity)
More informationSPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION
ISO-400 ISO-900 SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER Model: ODM-36A FEATURES Microprocessor based 4-wire transmitter suitable for field installation. The unit features isolated inputs
More information} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).
ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,
More informationHigh-sensitivity with vertical hole. PFA 2.6/cm (260/m) C 1.0 MPa or less Approx. 19kg Approx. 10kg (L: 500) Outdoor installation Rainproof type
High Sensitivity Type Electromagnetic Conductivity Detector ME-6 /7 /T Series These products are conductivity sensors that function based on electromagnetism. Combined with a dedicated converter, they
More informationDissolved Oxygen Transmitter (For Low-Concentration Measurement) OBM-165H
Dissolved Oxygen Transmitter (For Low-Concentration Measurement) OM-65H The OM-65H is a -wire type (4VDC power supply) dissolved oxygen transmitter (for Low-Concentration Measurement) housed in a robust,
More informationConductivity Analyzer
Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures
More informationEndress Hauser. SmarTec M CLD 133 Conductivity Measurement
Technical Information / Operating Instructions TI 281C/07/en/08.02 No. 51506567 SmarTec M Conductivity Measurement Compact conductivity transmitter with inductive sensor and integrated temperature compensation
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationMultifunction Pulse-to-Pneumatic Converter
No. SS2-APN100-0100 Multifunction Pulse-to-Pneumatic Converter Model J-APN11 OVERVIEW The Multifunction Pulse-to-Pneumatic Converter receives an up/down pulse signal to drive a 4-phase pulse motor and
More informationManostar Electronic Low Differential Pressure Measurement System
Manostar Electronic Low Differential Pressure Measurement System Manosys Presure Transmitter Intrinsically safe apparatus type Explosion-proof performance iag Intrinsically-safe apparatus is called by
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationCondumax CLS21 and CLS21D
Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:
More informationConductivity Transmitter
Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationThermoPLUS Smart Temperature Transmitter
No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationCondumax CLS21 and CLS21D
Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:
More informationwww. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER
www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring
More informationTechnical Information Condumax CLS15D/CLS15
TI0009C/07/EN/4.4 7268306 Products Solutions Services Technical Information Condumax CLS5D/CLS5 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 0.0 cm or k = 0. cm Application
More informationGC83 Digital Indicators & GC93 Digital Meter Relay
Cat.No. B- GC83 Digital Indicators & GC93 Digital Meter Relay OUTLINE Model GC83 has been designed exclusively for indication. Model GC93 is equipped with a comparator like a relay and is applied to a
More informationConductivity measurement SmarTec S CLD 132
Technical Information TI 207C/24/ae Conductivity measurement SmarTec S CLD 132 Transmitter for measurement of conductivity and concentration with inductive sensor Areas of application Alkali/acid concentration
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationProcess ph/orp Analysis Systems
Process ph/orp Analysis Systems A SAMPLER OF SAMPLERS The HORIBA K-8 process ph (ORP) analysis system features a systematic combination of functional component units which offers the versatility needed
More informationMulti-electrode Conductivity Analyzers
Data Sheet Multi-electrode Conductivity Analyzers Utilizes patented, six-electrode measurement techniques to give accurate results at up to 90% cell fouling enhanced performance and minimized maintenance
More informationSmart Electromagnetic Flowmeter Open channel Flowmeter Detector
No. SS2-MGN200-0200 MagneW3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIEW The MagneW3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter
More informationResistance thermometers for process technology
Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationTechnical Information Smartec CLD18
TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring
More informationMS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM
CIAO SENSOR MS 5000 EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3
More informationTechnical Information Smartec CLD18
TI01080C/07/EN/01.12 71195835 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application The compact measuring
More informationInductive Proximity Sensor
Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of
More informationEGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions
More informationModus M Series. General Eastern Differential Pressure Transmitters. GE Sensing
The Modus M Series family of differential pressure transmitters measure low pressures, and feature a variety of analog signal outputs with low power consumption. A wide selection of standard pressure ranges
More informationConductive conductivity measurement mypro CLM 431 / CLD 431 conductive
Technical Information TI 202C/07/en No. 51500563 Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive Two-wire transmitter for conductive measurement of conductivity and specific resistance
More informationWorld-Class Accuracy & Measurement Range (40 Conventional Models)
AC/DC CURRENT SENSOR CT6904 Ultra-High Performance AC/DC Current Sensor World-Class Accuracy & Measurement Range (40 Conventional Models) 500 A (rms) Rated for measurement of large currents 4 MHz (±3 db)
More informationMODEL EPM-96 EPM-96F. ph 0 to ph14: Resolution 0.01pH 0 to 100 :Resolution temp. 1 (Selection display)
10. Maesuring Instruments 10-1. MODEL: EPM -96, EPM-96F MODEL EPM-96 EPM-96F ph 0 to ph14: Resolution 0.01pH 0 to 100 :Resolution temp. 1 (Selection display) (in equivalent input) Less than ±0.05pH 4 ma
More informationJUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor
sales@jumo.co.uk info.us@jumo.net Vorläufig V Page 1/8 JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor Cell constants K = 0.01 1.0 202922 Series for universal application, e.g.
More informationMonocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS
DRS 300 1 Monocrystalline silicon smart differential pressure transmitter DRS300 High stability Detailed Information application the flow of gas, vapor and liquid measurement with device (volume or mass
More informationOvertravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0
Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.
More informationDRS390 High stability, flange mounting
DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device
More informationINSTRUCTION MANUAL ADMITTANCE LEVEL LIMIT SWITCH LEVTESTER - SLA SERIES Models SLA-122/222/322/622/522/722
INSTRUCTION MANUAL ADMITTANCE LEVEL LIMIT SWITCH LEVTESTER - SLA SERIES Models SLA-122/222/322/622/522/722 INTRODUCTION : `SAPCON' Admittance Level Limit Switch utilizing specially designed immuno coat
More information6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES
6GHz Intelligent Radar Level Meter Product Manual Model:KRD520 SERIES Directory 1 Product Overview...1 2 Product Introduction...2 3 The Installation Requirements...4 4 The Electrical Connection...6 5 Instrument
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationKFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite
KFS Flap Flow Meter KFS suitable for H, acids, alkalis and gases spring-loaded horizontal or vertical flow direction low pressure loss mainly viscosity independent optional threshold value contacts optional
More informationTechnical Information Condumax CLS21D/CLS21
TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application
More informationInductive conductivity transmitter JUMO CTI-Junior
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net
More informationSeries 10-ZSE80/10-ISE80
Series 0-ZSE80/0-ISE80 RoHS -Color Display Digital Pressure Switch For General Fluids Directional Control Valves For positive 0 80 For vacuum/ compound 80 80F N P B R T S V Rated range Symbol -X50 Clean
More informationBlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells
D-42607 Solingen Postfach 10 07 08 D-42659 Solingen Ritterstr. 87-89 Phone +49 212 81 40 45-46 Fax +49 212815500 e-mail: mail@juchheim-solingen.de Internet: www.juchheim-solingen.de Data Sheet 20.2922
More informationKMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display
KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical
More informationSmart Electromagnetic Flowmeter Open channel Flowmeter Detector
Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow
More informationUSER S MANUAL. Rail-mounted temperature transmitter ATL
IO.ATL (ENG) USER S MANUAL Rail-mounted temperature transmitter ATL APLISENS S.A., 03-192 Warszawa, ul. Morelowa 7 tel. +48 22 814 07 77; fax +48 22 814 07 78 www.aplisens.pl, e-mail: aplisens@aplisens.pl
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More informationSeries 10-ZSE30A(F)/10-ISE30A
Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationPrecision Thermistor Sensors
Precision Thermistor Sensors For Laboratory Applications ON-400 Series U For Use in Laboratory or Other High-Accuracy Applications U Rugged Construction Can Be Used for Short Term Water and Soil Readings
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationSPECIFICATIONS Type Catalog listing Power supply Consumption current Detecting distance Focal distance Focal spot diameter Operation mode
Long-Distance Detection Laser Sensors Model High-accuracy detection of very small targets using the direct reflection method. Detecting a long distant and very small spot. Switching output type: 0.1 mm
More informationUNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550
UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY K-RELAYS.0 a UL File No.: E3 CSA File No.: LR2550.0.8 00 times more reliable than similar designs Extra long life Mechanical: more than 0 8 operations Electrical
More informationElectromagnetic flowmeters and switches DWM 1000/2000
KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass
More informationTechnical Information Memosens CLS82D
TI01188C/07/EN/03.16 71318348 Products Solutions Services Technical Information Memosens CLS82D Hygienic conductivity sensors, digital with Memosens technology, cell constant k = 0.57 cm -1 Application
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationINTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:
Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:
More informationM1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL
M1 Series Humidity - Temperature Transmitter INSTRUCTION MANUAL 20031110 -2- CONTENTS Overview... 3 Operation... 4 Power supply... 4 Operating range and limits... 4 Temperature compensation of the humidity
More informationPTG series Smart Pressure Transmitter
No. SS2-PTG300-0100 PTG series Smart Pressure Transmitter Model PTG71 / PTG72 OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure transmitter. Based
More informationRoline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL
Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationConductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16
Technical Information TI 7C//ae Conductivity Measuring Cells for High-Temperature Applications Two-electrode measuring sensors with fixed cable or connector version with integrated temperature sensor Cell
More informationMaintenance: Check the measurement signal: regularly required once a month Calibration: typically 6 to 12 months after installation
The SMR digital transmitters have been developed especially for use in liquids for pressure, differential pressure, hydrostatic level and water quality measurement such as free chlorine, ph, ORP, temperature,
More informationMeasuring and Controlling Unit Multronic OC
Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously
More informationCATALOG LISTING SPECIFICATIONS 11 30mA 22 to 130mm (White Paper), 22 to 70mm (Black Paper) 3 to 130mm (White Paper) Ambient light Seal
Convergent Laser Measurement Sensor Model HLB-D130DN Very small or thin parts can be detected by differences in distance, unaffected by color or reflection rate of the target object. Size (12 x 16.3 x
More informationUltra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26
Electronic pressure measurement Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26 WIKA data sheet PE 87.07 Applications Gas panels for OEM tools Semiconductor, flat panel display and
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationCAPACITANCE TYPE LEVEL SWITCH FOR LIQUIDS 114 MLS
LEVEL MEASUREMENT & CONTROL SOLUTIONS CAPACITANCE TYPE LEVEL SWITCH FOR LIQUIDS 114 MLS Capacitance Type Level Switch 114 MLS uses SBEM s proven capacitance technology with added feature of Microprocessor.
More informationMODEL: W2DYS SEN TRONIC AG. Mini-MW Series
MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters
More informationMODEL: M2DYS SEN TRONIC AG
Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical
More informationQFM21... Duct sensors. Symaro. for relative humidity and temperature
1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationInductive conductivity measurement mypro CLM 431 / CLD 431 inductive
Technical Information TI 195C/07/en No. 51500053 Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive Two-wire transmitter for inductive measurement of conductivity in Ex and non-ex areas
More informationTest Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com DIGITAL SUPER MEGOHMMETER DSM-8104, DSM-8542
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com DIGITAL SUPER MEGOHMMETER, DIGITAL SUPER MEGOHMMETERS (Single-Channel) (Four-Channel) Options Supporting
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationMagnetic-Inductive flow Meter fmi
1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in food and
More informationEC centrifugal fan - RadiCal
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationProducts for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers
Products for High Voltage Application AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers Technical parameters Value Highest voltage for equipment 1.2 kv Power frequency voltage,
More informationWL Product Range Performance Comparison
NEW PRODUCT INFORMATION Splash Proof Fan SANYO DENKI EUROPE SA. is pleased to introduce its new San Ace 4 9WL DC fan, measuring 4mm square by 28mm thick models. This cooling fan delivers IP68 rated water
More informationFH CMF Coriolis Mass Flow Meters
FH CMF Coriolis Mass Flow Meters 1. Introduction Coriolis Mass Flow Meters patented and developed by our company (Chinese Patent No. 03119685.3, 03149996.1) are the leading meters for precision flow measurement.
More informationHumidity Temperature Sensor TFG80 Duct version with Polyga measuring element
Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH D-71145 Bondorf. Germany D-07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0. Fax +49 (0)7457-3758 Tel. +49(0)3661-62704-0.
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More information