Industrial Conductivity (Electric Conductivity) Detector
|
|
- Darren Bishop
- 6 years ago
- Views:
Transcription
1 Industrial Conductivity (Electric Conductivity) Detector / (General Multi-Purpose Use) R/R (Compact Ultra-Pure Water Use) S (Intrinsically Safe) The -electrode type industrial conductivity (electric conductivity) detector is perfectly suited for use in a broad range of measurement applications. In addition to measuring the conductivity of ultra-pure water used in the semiconductor manufacturing process or in powergenerating plants, it can also be used to measure the conductivity of river water and wastewater. This series features a wide range of installation types, including an insertion type, immersion/submerged type, and flow-through type. For high conductivity solutions and applications, such as sea water ( µs/cm or greater) or chemicals that contain strong levels of acid and alkali, see the specification sheets for electromagnetic induction type detectors. For details about use in food processing and beverage plants, see the specification sheet for the sanitary type conductivity detector. screw-in type flange type with flow through type SUS case Features with flow through R screw-in type R screw-in type There are four types of cell constants available:., type PP case.,, and /cm. These cell constants make it possible to obtain accurate measurement results for a number of different water types, such as ultra-pure water (. µs/cm or less) and wastewater ( µs/cm). Hermetic seal and PTFE (Teflon) as insulater between the inner and outer electrodes provise excellent heat and pressure resistance. The integrated junction box makes it easy to both connect to a transmitter as well as remove the detector. The compact and lightweight R/ detectors for ultrapure water are perfectly suited for all types of installations. Typical Configuration <-wire system> Detector Transmitter Model : WDM- On-site Instrument room EC- Extension cable ( m or less) Power/transmission output (V DC, ~ m) Distributor DC power Receiver R Indicator Recorder Controller DCS, etc
2 Standard Specifications Model pplication/feature Cable connection Installation type Wetted part materials Sample temperature Sample pressure Temperature compensation element Construction S R R Submerged type General use Intrinsically safe Compact ultra-pure water use Waterproof/direct connection Connector Stainless chain Screw-in, flange, or flow-through type R/ screw-in or flow-through type SUS, glass hermetic seal, PTFE Titanium, PPS, FKM. /cm,. /cm, /cm or /cm./cm or./cm ~ºC* ~ ()ºC* ~ºC*. MPa or less. (.) (.) MPa or less. MPa or less *No freezing. Outdoor installation, water-proof type Thermistor ( kω at ºC) Indoor installation Cell Constant and Measurement Range (S/m : SI unit) Sample classification Measurement range Unit Ultra-pure Pure ~ ~ boiler ~ Rain water ~ City ~ water Industrial waste ~ water water water (groundwater) water River water (*)./cm (./m)./cm (/m) /cm (/m) /cm (/m) ~. () ~. () ~ () ~ () ~ () ~. () ~. () ~ () ~ () ~ () ~. () ~ () ~ () ~ () ~ () µs/cm (µs/m) µs/cm (µs/m) µs/cm (ms/m) µs/cm (ms/m) ms/cm (ms/m) * : detector with a cell constant of /cm can be used for measurement ranges of ms/cm (ms/m) or greater. However, for high conductivity applications we recommend using electromagnetic induction type conductivity analyzers that are user-friendly and capable of delivering high-performance. /S Detectors cell series (general use) model name cell series schematic diagra Cable connection Direct connection (submerged type only) Via junction box lways (Temperature compensation: Universal structure for both general water and ultra-pure water) Process connection Insertion type or immersion type, screw-in connection Insertion type or immersion type, flange connection Flow-through type with SUS case, thread connection Flow-through type with SUS case, flange connection Flow-through type with PP case, thread connection Flow-through type with PP case, flange connection Immersion type or submerged type (no connection part) ( nominal value)./cm (/m)./cm (/m) /cm (/m) /cm (/m) Hermetic seal (glass) Insulator (PTFE) Inner electrode (SUS) Outer electrode (SUS)
3 S cell series (intrinsically safe) model name S lways (Via junction box) lways (Temperature compensation: Universal structure for both general water and ultra-pure water) Process connection Insertion type or immersion type, screw-in connection Insertion type or immersion type, flange connection Flow-through type with SUS case, thread connection Flow-through type with SUS case, flange connection Flow-through type with PP case, thread connection Flow-through type with PP case, flange connection (nominal value)./cm (/m)./cm (/m) /cm (/m) /cm (/m) Dimensions Unit : mm Pipe insertion type Models: -, S- Minimum liquid level Minimum liquid level Electrode part Electrode part Cell adapter s:.,.,. /cm s: /cm Flange type Models: -, S- Immersion type Models: -, S- Mounting flange Mounting flange Minimum liquid level Electrode part Minimum liquid level Electrode part Cell adapter Minimum liquid level s:.,.,. /cm s: /cm Electrode part
4 Flow-through type with SUS case (Thread connection) Models: -, S- Flow-through type with SUS case (flange connection) Models: -, S- Submerged type Model: - Stainless rope Wire clip Detector lead Flange Holding fixture Rc/ Sample outlet Case Sample outlet Case Flange Electrode part Sample inlet Screw thread specification: Rc / Sample inlet Flange specification: JIS K RF Standard specifications for /S detectors Product name Models Items measured mbient temperature /humidity Sample conditions : Temperature range Pressure range Flow velocity or flow rate : Industrial conductivity detector :(general use), S (intrinsically safe) : Conductivity of ultra-pure water, pure water, industrial water, wastewater etc. :.,.,., /cm : -~ºC, %RH or less ; ~ºC (polypropylene case) ~ºC (SUS case) No freezing ;. MPa or less (up to the nominal pressure capacity of the flange when connected to a flange;. MPa or less when equipped with a PP case) ;.~ m/s (flow rate of.~ L/min for detectors with a case) Temperature sensor Materials Cable connection Weight Paint color Construction : Thermistor : ody; SUS ; Cast aluminum Electrode; SUS Electrode insulator: Glass (hermetic seal), PTFE (Teflon) Case; SUS or PP (polypropylene) : etc. : pprox.. kg (screw-in type with R/) : ; Metallic silver : Water-proof type
5 Product code Screw-in type Model: - code; Numeric digit: lphabet: Electrode material SUS: Standard SUSL (including thread part) Screw thread specification * R/: Standard R NPT/ M cap nut (for use with a flow-through type case) Length (below thread) L *././ mm mm : Standard mm mm,mm,mm,mm,mm,mm,mm lways lways lways./cm./cm /cm /cm (SI unit system) /m /m /m /m ssembly with cable port adapter, G/: Standard G/ SUS NPT/ SUS NPT/ SUS Degreasing * Provided Combined transmitter * Flange insertion type Model: - D-- D-- C code; Numeric digit: lphabet: Electrode material SUS: Standard SUSL (including flange part) lways lways Flange specification JIS K FF: Standard JIS K FF: Compatible with WS- sensor part " NSI L RF Length (below flange) *././ mm mm : Standard mm mm mm mm,mm,mm,mm,mm,mm,mm lways./cm./cm /cm /cm (SI unit system) /m /m /m /m ssembly with cable port adapter, G/: Standard G/ SUS NPT/ SUS NPT/ SUS Degreasing * Provided Combined transmitter * *. If the length (below thread) L is greater than () mm, the extension grows thicker. For this reason, select the R thread (note that the R/ thread cannot be used). protection pipe to support the detector is required if the L length is mm or more and the sample flow velocity is greater than. m/s (rough estimate). *. Degreasing means cleaning the wetted electrode part with alcohol. *. If the detector is not equipped with a transmitter, please provide us with the model and serial number of the existing transmitter. : ecause the cell is equipped with a junction box, an extension cable is required. Order the EC- extension cable (outside diameter: ømm) separately. : Sample temperature range: ~ºC. Max. pressure:. MPa. : We recommend using electromagnetic induction type detectors for performing high conductivity measurements with a cell constant of /cm (/m). *. protector pipe to support the detector is required if the L length is mm or more and the sample flow velocity is greater than. m/s (rough estimate). *. Degreasing means cleaning the wetted electrode part with alcohol. *. If the detector is not equipped with a transmitter, please provide us with the model and serial number of the existing transmitter. : ecause the cell is equipped with a junction box, an extension cable is required. Order the EC- extension cable (outside diameter: ømm) separately. : Sample temperature range: ~ºC, Max. pressure:. MPa (flange nominal pressure) : We recommend using electromagnetic induction type detectors for performing high conductivity measurements with a cell constant of /cm (/m).
6 code; Numeric digit: lphabet: Electrode material SUS : Standard SUSL lways lways lways lways Immersion length L *././ mm mm,mm,mm,mm,mm,mm,mm./cm./cm /cm /cm (SI unit system) /m /m /m /m ssembly with cable port adapter, G/: Standard G/ SUS NPT/ SUS NPT/ SUS Degreasing * Provided Combined transmitter * Immersion type Model: - D-- Submerged type Model: Wetted part (electrode) material SUS : Standard SUSL Lead length (outside diameter : ø.) m m m m m m *./cm./cm /cm /cm (SI unit system) * /m /m /m /m Combined transmitter * *. Select the cell constant that corresponds to the measurement range (the same value as indicated on the transmitter). *. If the detector is not equipped with a transmitter, please provide us with the information (serial number) of the existing transmitter. Note that even if the detector is equipped with a transmitter, a separate transmitter is still required. *. protector pipe to support the detector is required if the L length is mm or more and the sample flow velocity is greater than. m/s (rough estimate) *. Degreasing means cleaning the wetted electrode part with alcohol. *. If the detector is not equipped with a transmitter, please provide us with the model and serial number of the existing transmitter. : ecause the cell is equipped with a junction box, an extension cable is required. Order the EC- extension cable (outside diameter: ømm) separately when using the cell. In addition, because the - is an immersion type detector, mounting brackets are required. ou can prepare these brackets on-site or order them separately. : Sample temperature range: ~ºC, Pressure: tmospheric pressure since the detector is an immersion type. : We recommend using electromagnetic induction type detectors for performing high conductivity measurements with a cell constant of /cm (/m). : This model is a submerged type conductivity detector with a compact electrode. The length of the electrode is mm or mm (total length: mm, max. diameter: ø). The detector is equipped with a stainless wire designed to reinforce the detector lead. : The service temperature and pressure range are as follows: Temperature: ~ºC Pressure:. MPa or less (water depth: max. m) : When performing high conductivity measurements with a cell constant of /cm (Model: -), air bubbles often form on the inner electrode. These air bubbles can cause the efficiency of sample water displacement to deteriorate. We recommend using the electromagnetic conductivity detector ME- for high conductivity applications.
7 Flow-through type with stainless case (thread connection) Model: - F-- (Stainless) code; Numeric digit: lphabet: Electrode material SUS : Standard SUSL Screw thread specification for connecting with a stainless case SUS RC/ : Standard SUS RC/ : Supports assembly with SC SUS NPT/ SUS NPT/ SUSL RC/ SUSL RC/ SUSL NPT/ SUSL NPT/ lways lways lways./cm./cm /cm /cm (SI unit system) /m /m /m /m ssembly with cable port adapter, G/ : Standard G/ SUS NPT/ SUS NPT/ SUS Degreasing * Provided Combined transmitter * *. IDegreasing means cleaning the wetted electrode part and case with alcohol. *. IIf the detector is not equipped with a transmitter, please provide us with the model and serial number of the existing transmitter. : ecause the cell is equipped with a junction box, an extension cable is required. Order the EC- extension cable (outside diameter: ømm) separately. : Sample temperature range: ~ºC. Max. pressure:. MPa : We recommend using electromagnetic induction type detectors for performing high conductivity measurements with a cell constant of /cm (/m).
8 Flow-through type with stainless case (flange connection) Model: - F-- C D W E F G H J (Stainless) code; Numeric digit: lphabet: Electrode material SUS : Standard SUSL lways Flange specification for connecting to a stainless case * SUS JISK RF : Standard SUS JISK RF SUS /" NSI L RF SUS " NSI L RF SUS JISL RF : Compatible with WS- SUSL JISK RF SUSL JISK RF SUSL /" NSI L RF SUSL " NSI L RF SUSL JISL RF : Compatible with WS- lways lways./cm./cm /cm /cm (SI unit system) /m /m /m /m ssembly with cable port adapter, G/ : Standard G/ SUS NPT/ SUS NPT/ SUS Degreasing * Provided Combined transmitter * *. When using a ( ) flange, be sure to select a (/ ) pipe (sample in/out pipe diameter). *. Degreasing means cleaning the wetted electrode part and case with alcohol. *. If the detector is not equipped with a transmitter, please provide us with the model and serial number of the existing transmitter. : ecause the cell is equipped with a junction box, an extension cable is required. Order the EC- extension cable (outside diameter: ømm) separately. : Sample temperature range: ~ºC. Max. pressure:. MPa : We recommend using electromagnetic induction type detectors for performing high conductivity measurements with a cell constant of /cm (/m).
9 Flow-through type with polypropylene case (thread connection) Model: - F-- (Polypropylene) code; Numeric digit: lphabet: Electrode material SUS : Standard SUSL lways lways Screw thread specification for connecting to polypropylene case * RC/ : Standard lways./cm./cm /cm /cm (SI unit system) /m /m /m /m ssembly with cable port adapter, G/ : Standard G/ SUS NPT/ SUS NPT/ SUS Degreasing * Provided Combined transmitter * *. ecause the polypropylene case is a molded case, only a Rc/ thread connection can be used. *. Degreasing means cleaning the wetted electrode part and case with alcohol. *. If the detector is not equipped with a transmitter, please provide us with the model and serial number of the existing transmitter. : ecause the cell is equipped with a junction box, an extension cable is required. Order the EC- extension cable (outside diameter: ømm) separately. : Sample temperature range: ~ºC, Max. pressure:. MPa : We recommend using electromagnetic induction type detectors for performing high conductivity measurements with a cell constant of /cm (/m).
10 Flow-through type with polypropylene case (flange connection) Model: - F-- (Polypropylene) code; Numeric digit: lphabet: Electrode material SUS : Standard SUSL lways lways lways Flange specification for connecting to a polypropylene case JIS K FF : Standard JIS K FF *./cm./cm /cm /cm (SI unit system) /m /m /m /m ssembly with cable port adapter, G/ : Standard G/ SUS NPT/ SUS NPT/ SUS Degreasing * Provided Combined transmitter * *. The face-to-face flange dimensions for flanges are (W) x (H). When using a flange, be sure to select a (/ ) pipe (sample in/out pipe diameter). *. Degreasing means cleaning the wetted electrode part and case with alcohol. *. If the detector is not equipped with a transmitter, please provide us with the model and serial number of the existing transmitter. : ecause the cell is equipped with a junction box, an extension cable is required. Order the EC- extension cable (outside diameter: ømm) separately. : Sample temperature range: ~ºC. Max. pressure:. MPa : We recommend using electromagnetic induction type detectors for performing high conductivity measurements with a cell constant of /cm (/m).
11 Insertion type (intrinsically safe) Model: S SD-- Screw-in C Flange /Electrode material SUS : Standard SUSL Screw-in type pipe connector specification * N (= flange connection type) R/ (PT/): Standard R (PT) NPT/ M cap nut (for use with a case) (no applicable screw specification/no connection part) Length (below thread) of screw-in type detector* N (=flange connection type).~ mm mm : Standard mm mm,mm,mm,mm,mm *,mm,mm * (length below thread) * Flange type pipe connector specification N (= screw-in type connector) JIS K FF : Standard JIS K FF " NSI L RF (flange specification Length (below flange) of flange type detector * N (= screw-in type connector).~ mm mm : Standard mm mm : Compatible with flow-through type SWS cell mm mm,mm,mm,mm,mm,mm,mm (length below flange)./cm./cm /cm /cm /m (SI unit system) /m (SI unit system) /m (SI unit system) /m (SI unit system) ssembly with cable port adapter, G/ (PF/) : Standard G/ (PF/) SUS NPT/ SUS NPT/ SUS Combined transmitter model SECP-T Combined transmitter * *. If the length (below thread) L is greater than () mm, the extension grows thicker. For this reason, select the R thread (note that the R/ thread cannot be used). *. protector pipe is required if the length(below thread or flange) is mm or more and the sample flow velocity is greater than. m/s (rough estimate). The purpose of this pipe is to prevent the detector from breaking. (Exercise extra caution when using a tank with a builtin agitator.) *. If the detector is not equipped with a transmitter, please provide us with the information (serial number) of the existing transmitter. Note that even if the detector is equipped with a transmitter, a separate transmitter is still required. : The service temperature and pressure range are as follows: : We recommend using electromagnetic induction type detectors for performing high conductivity measurements with a cell constant of /cm (/m). Model: SECP-T ~ºC Screw-in type:. MPa or less Flange type:. MPa or less
12 Flow-through type (intrinsically safe) Model: S SF-- (Stainless) Stainless (Polypropylene) C D W PP /Electrode material (case excluded) SUS : Standard SUSL Thread connection type with SUS case N RC/: Standard RC/ NPT/ NPT/ (screw thread specification, case material) * Flange connection type with SUS case N JIS K RF : Standard JIS K RF * Face-to-face flange dimensions: /" NSI L RF (H) x (W) " NSI L RF * JIS K RF Face-to-face flange dimensions : (H) x (W) (flange specification, case material) * Thread connection type with polypropylene case N RC/ : Standard (screw thread specification) * Flange connection type with polypropylene case N JIS K FF : Standard JIS K FF * * (flange specification)./cm./cm /cm /cm /m (SI unit system) /m (SI unit system) /m (SI unit system) /m (SI unit system) ssembly with cable port adapter, G/ (PF/) : Standard G/ (PF/) SUS NPT/ SUS NPT/ SUS Combined transmitter model SECP-T Combined transmitter* *. Sample in/out pipe size: (/ ). *. The polypropylene case is a molded case. Contact us in advance for information about custom sizes. *. If the detector is not equipped with a transmitter, please provide us with the information (serial number) of the existing transmitter. Note that even if the detector is equipped with a transmitter, a separate transmitter is still required. *. If the case material is SUSL, select (thread) / (flange) for the custom spec. codes. *. The face-to-face flange dimensions are only (H) x (W) when using the flange connection type with a polypropylene case. : The service temperature and pressure range are as follows: Model: SECP-T ~ºC Stainless case type:. MPa or less, ºC or lesspolypropylene case type:. MPa or less, ºC or less : We recommend using electromagnetic induction type detectors for performing high conductivity measurements with a cell constant of /cm (/m).
13 R Detectors R cell series model name (compact ultra-pure water use) R - Cable connection Connector Via junction box lways (Temperature compensation : for ultra-pure water) lways (Insertion type, screw-in connection) (design value)./cm (/m)./cm (/m) Standard specifications for R detectors Product name Models s Temperature sensor Sample conditions Materials Pipe connection Heat resistance Extension cable : Electric conductivity analyzer detector : R-, R- : pprox.. /cm, approx.. /cm : Class. level thermistor (sealed inside inner electrode) : Temperature; ~ºC (no freezing) Pressure;. MPa or less : Electrode; Titanium ushing; SUS (Teflon coated) Seal; Fluororubber Connector (R); Plastic (R); Cast aluminum : R/, Screw-in : ~ºC : Outside diameter: ømm. Standard length: m (max. m). with drip-proof connector (for R) R cell series dimensions Unit : mm Screw-in type Model: R- Flow-through type with case Model: R- Connector type extension cable Model: EC- Electrode lead Electrode lead Connector Hexagon width across flats: Connector Hexagon width across flats: Standard m (max. m) Mounting screw Mounting screw Sample outlet Connector Case Electrode part Sample inlet Screw-in type Model: R- Flow-through type with case Model: R- type extension cable Model: EC- Hexagon width across flats: Mounting screw R/ Case Hexagon width across flats: Sample outlet Electrode lead Sample inlet
14 Product code Model: R (connector type) Model: R (junction box type) R- R- R-- R-- Connection specification R/ (PT/) : Standard Combined transmitter Resistivity analyzer Conductivity analyzer Case connection specification : Rc/ (SUS)./cm./cm R- R- Connection specification R/ (PT/) : Standard Paired transmitter Resistivity analyzer Conductivity analyzer Case connection specification : Rc/ (SUS)./cm./cm : The main material used in the electrodes is titanium. PPS is used for the insulation between the inner and outer electrodes. The O-ring insulating seal is made of FKM (Fluororubber). The instruments are not water-proof. Make sure to install the instruments indoors. : Sample conditions: Temperature: ~ºC, Pressure:. MPa or less : The EC- extension cable is not attached. Order separately. : The main material used in the electrodes is titanium. PPS is used for the insulation between the inner and outer electrodes. The O-ring insulating seal is made of FKM (Fluororubber). The instruments are not water-proof. Make sure to install the instruments indoors. : Sample conditions: Temperature: ~ºC. Pressure:. MPa or less : The EC- extension cable is not attached. Order separately. Supported Conductivity nalyzer/transmitter Models Field installation type (-wire system) / (-wire system) WDM-/WDM- Intrinsically safe (-wire system) SECP-T Field installation type conductivity analyzer/transmitter with built-in microcomputer and water-proof construction djustable transmission output range (~ m DC) Output can be held when in maintenance mode Power supply: -wire system: V DC -wire system: ~V C Units displayed in S/cm and S/m(SI unit system) Measurement range: ~// µs/cm, ~ms/cm, ~ µs/m, ~// ms/m Intrinsically safe explosion proof construction that conforms to IEC (Ex) standards lterable transmission output range (~ m DC) Output can be held when in maintenance mode Power supply: -wire system, V DC Units displayed in S/cm and S/m(SI unit system) Measurement range (S/cm example) ~/// µs/cm or ms/cm ~///// µs/m
15 Field installation type (-wire system) WM- Field installation type (-wire system) WM-H Conductivity analyzer housed in a sturdy die-cast aluminum enclosure and equipped with a variety of practical features Two circuit transmission output for conductivity and sample temperature (~ m) lterable transmission output range (~ m DC) High and low limit alarm contacts Can be fitted with RS-C output (optional feature) Power supply: ~VC Units displayed in S/cm and S/m(SI unit system) Measurement range: ~// µs/cm, ~ ms/cm, ~ µs/m, ~// ms/m HRT communication interface (version ) using a wire, VDC circuit Conductivity analyzer housed in a sturdy die-cast aluminum enclosure and equipped with a variety of practical features One touch auto calibration Self diagnosis Power supply: VDC Units displayed in S/cm and S/m(SI unit system) Measurement range: ~// µs/cm, ~ ms/cm, ~ µs/m, ~// ms/m Panel mount type WM- / WM- Compact DIN size unit bility to connect two detectors to WM- ( channels) lterable transmission output range (~ m DC) High and low limit alarm contacts (-point alarm available) RS-C equipped as standard (WM-) Power supply: ~VC Units displayed in S/cm and S/m(SI unit system) Measurement range: ~// µs/cm, ~ ms/cm, ~ µs/m, ~// ms/m Extension cable The extension cable is a special cable designed for use with conductivity analyzers. It is used to connect the transmitter to the detector. Conductor (. mm ) PE insulation (natural color) Filler Semi-conductive PVC Cloth tape winding Shielding Shielding PET tape winding PVC sheath PE core sheath (black) PE insulation (blue) Conductor (. mm ) PE insulation (green) PE insulation (red) Model Outside diameter Insulation Sheath Insulation resistance between core conductors Maximum cable length Standard length Weight : EC- : ømm : Polyethylene and PVC : PVC : MΩ or greater/ m : m. No cable splicing. : m~ m ( m steps) : pprox.. kg/ m EC- cross section
16 When installing a conductivity detector, make sure to do the following:. Install the detector in a location that is free from excessive vibration and easily accessible for maintenance.. Install the detector in a location that is free from corrosive gases or chemicals.. Follow the recommended mounting procedure for insertion type detectors For a screw-in or flange connection insertion type detector, we recommend vertically mounting the detector on the upper end of the horizontal pipe. (Figure ) When mounting the detector on a vertical pipe, it can be mounted horizontally. (Figure ) Detectors with a cell constant of./cm or./cm can be mounted horizontally. Detectors with a cell constant of./cm or /cm must be mounted diagonally at a horizontal angle of degrees or greater. (Figure C) It is difficult to remove the bubbles that form inside the electrode. To help release the bubbles from the electrode, mount the detector diagonally. (ubbles that form inside the electrode can cause measurements to fluctuate.). Follow the recommended installation procedure for flow-through type detectors with a case Set the by-pass valve on the by-pass line and the stop valves on the IN/OUT lines. (Figure D) This makes it possible to perform maintenance while the plant is running by allowing you to close the stop valves and remove the detector. When mounting the ultra-pure water detector, make the by-pass pipe as short as possible. Case Stop valve Stop valve y-pass valve Flow velocity :.~ m/s Figure : Vertical mounting on horizontal pipes Detectors with a cell constant of./cm or./cm can be mounted vertically. Figure : Horizontal mounting on vertical pipes degrees or greater (The detector can also be mounted facing downward.) Detectors with a cell constant of./cm or /cm must be mounted at an angle of degrees or greater. Figure C : Diagonal mounting on vertical pipes y-pass flow rate :.~ L/min Figure D : Mounting the by-pass line for a flow-through type detector International Operations: DKK-TO Corporation -, -Chome, Takadanobaba, Shinjuku-ku, Tokyo - Japan Tel : +--- Fax : Information and specifications are for a typical system and are subject to change without nofice. Issued on //
WDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system
CONDUCTIVITY TRANSMITTR WDM-A (-wire type) WDM-6A (-wire type) It is a type of small firm aluminum -electrode site-installation CONDUCTIVITY TRANSMITTR (signal transmitter) and easy operate. The device
More informationHigh-sensitivity with vertical hole. PFA 2.6/cm (260/m) C 1.0 MPa or less Approx. 19kg Approx. 10kg (L: 500) Outdoor installation Rainproof type
High Sensitivity Type Electromagnetic Conductivity Detector ME-6 /7 /T Series These products are conductivity sensors that function based on electromagnetism. Combined with a dedicated converter, they
More informationDissolved Oxygen Transmitter (For Low-Concentration Measurement) OBM-165H
Dissolved Oxygen Transmitter (For Low-Concentration Measurement) OM-65H The OM-65H is a -wire type (4VDC power supply) dissolved oxygen transmitter (for Low-Concentration Measurement) housed in a robust,
More informationSPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION
ISO-400 ISO-900 SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER Model: ODM-36A FEATURES Microprocessor based 4-wire transmitter suitable for field installation. The unit features isolated inputs
More informationDissolved Oxygen Transmitter
Dissolved Oxygen Transmitter OBM-67H The OBM-67H is a -wire type (4VDC power supply) dissolved oxygen transmitter housed in a robust, die-cast aluminum enclosure suitable for installation out in the field.
More information} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).
ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,
More informationSPECIFICATION SHEET. 2-WIRE TYPE ph ANALYZER/TRANSMITTER SYSTEM CONFIGURATION
ISO-14001 ISO-9001 SPECIFICATION SHEET 2-WIRE TYPE ph ANALYZER/TRANSMITTER Model: HDM-135A FEATURES 2-wire ph transmitter with built-in microcomputer: Field installation type ph analyzer / transmitter
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationCondumax CLS21 and CLS21D
Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:
More informationTechnical Information Condumax CLS21D/CLS21
TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application
More informationCondumax CLS21 and CLS21D
Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationTechnical Information Condumax CLS15D/CLS15
TI0009C/07/EN/4.4 7268306 Products Solutions Services Technical Information Condumax CLS5D/CLS5 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 0.0 cm or k = 0. cm Application
More informationwww. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER
www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring
More informationMJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400
Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationB Operating Instructions V1.00/EN/
Conductive conductivity/ultra-pure water sensors with a 2-electrode system, types 202922, 202923, 202924, 202925 Glass conductivity sensors, type 202922/30 Diaphragm tubes, type 201083 Compensation thermometer,
More informationSTANDARD RTD's INDEX
STANDARD RTD's INDEX PAGE General Information... R2 Temperature/Resistance Table... R6 Part Numbering Examples... R10 High Temperature MgO Elements (RA)... R11 Leadwire Style RTD's (RB)... R12 Leadwire
More informationResistance thermometers for process technology
Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationConductivity Transmitter
Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationResistance Thermometers Model Series TR7X0, Sheathed Design
Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features
More informationSmart Displacer Level (Interface) Transmitter DLT100 Series
Smart Displacer Level (Interface) Transmitter DLT100 Series Equipped with FISHER FIELDVUE DLC3010 1 Introduction DLT100 series is Smart Displacer Level (Interface) Transmitter equipped with the original
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationJUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor
sales@jumo.co.uk info.us@jumo.net Vorläufig V Page 1/8 JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor Cell constants K = 0.01 1.0 202922 Series for universal application, e.g.
More informationInsertion Flow sensor for continuous flow measurement
Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface
More informationInductive conductivity transmitter JUMO CTI-Junior
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net
More informationTechnical Information Smartec CLD18
TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationKFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite
KFS Flap Flow Meter KFS suitable for H, acids, alkalis and gases spring-loaded horizontal or vertical flow direction low pressure loss mainly viscosity independent optional threshold value contacts optional
More informationConductivity Analyzer
Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures
More informationMeasuring and Controlling Unit Multronic OC
Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously
More informationSignet ph/orp Electrodes General Purpose
Signet 2724-2726 ph/orp Electrodes General Purpose Compatible with ALL Signet ph/orp instruments and SmartPro transmitters Features Patented reference design for exceptional performance and prolonged life
More informationElectromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P
Technical Information TI 049D/06/en 50097005 Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P Flow rate measurement in chemical or process applications Features and benefits
More informationWATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL
MicroChem Water Analysis System The MicroChem is a versatile multi-parameter instrument capable of being configured as a transmitter or PID controller. Specifically designed for drinking and wastewater
More informationOPTIFLUX 1000 Technical Datasheet
OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when
More informationEndress Hauser. SmarTec M CLD 133 Conductivity Measurement
Technical Information / Operating Instructions TI 281C/07/en/08.02 No. 51506567 SmarTec M Conductivity Measurement Compact conductivity transmitter with inductive sensor and integrated temperature compensation
More informationElectrical Temperature Measurement
Electrical Temperature Measurement Resistance Thermometers Model TR10-B, for Additional Thermowell Applications Machinery, plant and tank construction Energy and power plant technology Chemical industry
More informationIndumax CLS50/CLS50D. Technical Information
Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D
More informationBlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells
D-42607 Solingen Postfach 10 07 08 D-42659 Solingen Ritterstr. 87-89 Phone +49 212 81 40 45-46 Fax +49 212815500 e-mail: mail@juchheim-solingen.de Internet: www.juchheim-solingen.de Data Sheet 20.2922
More informationB Operating Instructions /
Conductivity/ultra-pure water measuring cells with a twin-electrode system Types 202922, 202923, 202924 and 202925 Glass conductivity cells, type 201080 Diaphragm tubes, type 201083 Compensation thermometer,
More informationOPTISENS ORP 8590 Technical Datasheet
OPTISENS ORP 8590 Technical Datasheet ORP sensor for water and wastewaster industry Large ceramic diaphragm and integrated Pt100 Special sensor design for all-purpose applications Low maintenance costs
More informationOPTISENS PH 8390 Technical Datasheet
OPTISENS PH 8390 Technical Datasheet ph sensor for water and wastewater industry Large PTFE diaphragm and integrated Pt100 Robust sensor design for harsh applications Low maintenance costs and a long life
More informationJ Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016
J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow
More informationQuick Start Guide LIQ-QSG-226, Rev F June Rosemount 226. Toroidal Conductivity Sensors
Quick Start Guide LIQ-QSG-226, Rev F June 2017 Rosemount 226 Toroidal Conductivity Sensors Safety Information WARNING! HIGH PRESSURE AND TEMPERATURE HAZARD Before removing the senosr, reduce the process
More informationMeasuring and Controlling Unit Multronic
Measuring and Controlling Unit Multronic Modular system Up to 3 measurement variables with control functions in one housing Free combination of the measurement variables ph / Redox / temperature / conductivity
More informationOvertravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0
Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.
More informationPTG series Smart Pressure Transmitter
No. SS2-PTG300-0100 PTG series Smart Pressure Transmitter Model PTG71 / PTG72 OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure transmitter. Based
More informationMineral-insulated resistance thermometers to EN
Data Sheet 90.2221 Page 1/6 Mineral-insulated resistance thermometers to EN 60 751 for temperatures from -50 (-200) to +600 C flexible sheath with shock-protected sensor as single or twin resistance thermometer
More informationGas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version
Mechatronic temperature measurement Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version WIKA data sheet TV 17.01 for further approvals see page 6 Applications
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationSeries 10-ZSE30A(F)/10-ISE30A
Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H
More informationSensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering
Change from one to two columns Data Sheet 10/10-3.61-EN Rev. D SensyTemp TSB (B R) Resistance thermometer for building automation, machine construction and environmental engineering Measurement made easy
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Protected Bulb Patented reference design for exceptional performance* Mounts in Signet standard fittings from
More informationTLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE
2-wire System Level Radar TLR3000 MICROWAVE level meter GENERAL The TLR3000 is a non-contact type continuous level meter using microwaves. It detects a level by measuring a reciprocating time of a microwave
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion
More informationTIDALFLUX 2300 F Technical Datasheet
Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to
More informationSmart Electromagnetic Flowmeter Open channel Flowmeter Detector
No. SS2-MGN200-0200 MagneW3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIEW The MagneW3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications 2- or 4-electrode technology Extended measuring range 0.05 S/cm... 500 ms/cm Process connections, materials, surface finish designed for use in hygienic applications
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationManostar Electronic Low Differential Pressure Measurement System
Manostar Electronic Low Differential Pressure Measurement System Manosys Presure Transmitter Intrinsically safe apparatus type Explosion-proof performance iag Intrinsically-safe apparatus is called by
More informationDigital flow ELEMENT transmitter for continuous flow measurement
ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor
More informationTechnical Information Smartec CLD18
TI01080C/07/EN/01.12 71195835 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application The compact measuring
More informationphix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812
PH, TEMPERATURE AND REDOX MEASUREMENT General The advanced and unique design of phix Compact ensures that your work is done fast, easy and with accuracy. The compact design offers a union in one end, and
More informationIn-Line Resistance Thermometers Model TR25
Electrical Temperature Measurement In-Line Resistance Thermometers Model TR25 WIKA Data Sheet TE 60.25 Applications Food and beverage industry, dairies, drink dispensers and bottling plants, breweries
More informationLevel gauges Series LT Level indicator, switch and transmitter for liquids
Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance
More informationUltra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26
Electronic pressure measurement Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26 WIKA data sheet PE 87.07 Applications Gas panels for OEM tools Semiconductor, flat panel display and
More informationSLIDE VANE FLOW METER SPECIFICATIONS
SLIDE VANE FLOW METER SPECIFICATIONS V20051 17.09 1. Outline Slide vane flow meter is vane type positive displacement flow meter, creating high accuracy measurement and low pressure loss by decreasing
More informationThermoPLUS Smart Temperature Transmitter
No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature
More informationTechnical Information Indumax CLS50D/CLS50
TI00182C/07/EN/16.15 71280313 Products Solutions Services Technical Information Indumax CLS50D/CLS50 Inductive conductivity sensor for standard, Ex and high-temperature applications Digital sensor with
More informationSakura Endress RCV-1000/1200. Average Temperature Measuring Element for Tank Gauging System
Technical Information TI 002 N/08/en/02.02 Average Temperature Measuring Element for Tank Gauging System RCV-1000/1200 Multi-point average temperature with tank inventory management control Introduction
More informationMetal tube variable area flowmeters for gases, liquids and steam
Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,
More informationSRS SEALED ROTARY SENSORS
SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance
More informationConductive conductivity measurement mypro CLM 431 / CLD 431 conductive
Technical Information TI 202C/07/en No. 51500563 Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive Two-wire transmitter for conductive measurement of conductivity and specific resistance
More informationSMARTPAT PH 1590 Technical Datasheet
SMARTPAT PH 1590 Technical Datasheet Digital ph sensor for the water industry 2-wire loop powered sensor with integrated transmitter technology Special sensor design for all-purpose applications Low maintenance
More informationprosonic T FMU230, FMU231
Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters
More informationIntrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications
More informationProcess ph/orp Analysis Systems
Process ph/orp Analysis Systems A SAMPLER OF SAMPLERS The HORIBA K-8 process ph (ORP) analysis system features a systematic combination of functional component units which offers the versatility needed
More informationED701 General Industry Pressure Transmitter
ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationDRS390 High stability, flange mounting
DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device
More informationInstruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)
Instruction Manual Model MLA & MLD Loop Powered Process Indicators Model MLD (Digital) Model MLA (Analog) 1. PREFACE The Model MLA and MLD field mounted indicators receive DC voltage or current signals
More informationTGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE
2-wire System Guided Radar Gauge TGR3000 MICRO-PULSE level meter GENERAL TGR3000 series is the 2-wire system Guided Radar Gauge which can continuously measure the level using micro-pulse. The micropulse
More informationTechnical Information Smartec CLD18
TI01080C/07/EN/03.16 71314717 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring
More informationMagneW Two-wire PLUS+ Two-wire Electromagnetic Flowmeter
OVERVIEW MagneW Two-wire PLUS+ Two-wire Electromagnetic Flowmeter The MagneW Two-wire PLUS+is a high performance electromagnetic flowmeter based on field proven Azbil Corporation s two-wire loop powered
More informationInstallation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN
Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement
More informationSMARTPAT COND 1200 Technical Datasheet
SMARTPAT COND 1200 Technical Datasheet Digital conductive conductivity sensor for the water and wastewater industry 2-wire loop powered sensor with integrated transmitter technology Wide measuring range
More informationCONDUCTIVE LEVEL PROBE
CONDUCTIVE LEVEL PROBE The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the genuine
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationIntrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751
Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable
More information