MODEL EPM-96 EPM-96F. ph 0 to ph14: Resolution 0.01pH 0 to 100 :Resolution temp. 1 (Selection display)
|
|
- Moses Palmer
- 5 years ago
- Views:
Transcription
1 10. Maesuring Instruments MODEL: EPM -96, EPM-96F MODEL EPM-96 EPM-96F ph 0 to ph14: Resolution 0.01pH 0 to 100 :Resolution temp. 1 (Selection display) (in equivalent input) Less than ±0.05pH 4 ma to 20 ma DC Input / Output isolated type Maximum load resistance: 900Ω range: Freely selectable within the measurement range 2 point (A1 A2) 4 point (A1 A2 A3 A4) Relay contact: SPDT(1c) 240 V AC, 3 A and 30 V DC, 3 A (resistance load) Contact Selectable from upper / lower limit operation (ON / OFF control) Select from "Abnormal warning" or "It is maintaining it." Selectable from upper / lower limit operation (ON / OFF control, Timesharing proportinal control) Select from "Abnormal warning" or "It is maintaining it." Contact input - 1 point (External input for holding) Calibration Automatic proofreading: 2 point Automatic potential stability judgment standardized solution ph2,ph4,ph9,ph10(jis) and ph7(jis) combination Manual proofreading: Differences more than arbitrary 2pH Temperature: 1point hold feature Select from "Previous value hold" or "Optional value hold" or "Continuous" However, only the previous value hold is available in the mainttenance mode. Self-diagnosis The proofreading is defective. The incompetent potential is abnormal. Electrode diagnosis Temperature sensor short-circuit. Outside measurement range The converter is abnormal. Control operation - Timesharing proportinal control Range of bound pair setting: 0.00pH to ph Proportional band: 0.01pH to 4.00 ph Cycle: 5~300 sec. Control shift : Shift amount 0% to 50% at cycle Automatic changeability of cycle: The cycle extends automatically according to deflection when entering the range (F zone) with deflection. F zone: 1% to 100% of proportional band The maximum extension time at cycle: 0 sec. to 300 sec. Amount of the maximum control: 50% to 100%(It operates regardless of the proportional band. ) ELEPON E.C.A.P. Corporation 10 Measuring Instruments 1
2 Temperature amends element 500Ω(25 ), 6.8kΩ(25 ), 1kΩ(0 ), 10kΩ(25 ), 350Ω(25 ), There is no amends. Selectable from the above Ambient environment Temperature: -5 to 45 Relative humidity: 20% to 85% (without dew condensation) Storage ambient -25 to 65 Rated voltage 100 V to 240 V AC, 50/60 Hz, 10VA (max.) Rated voltage 100 V to 240 V AC, 50/60 Hz, 15VA (max.) Indoor-use panel installation type Panel case: ABS Terminal: PBT Panel: Dust and water proof structure Protective structure Conforming standards Panel:IP65(IEC60529, JIS C0920) Rear case: IP20 Terminal: IP00 Class II equipment: IEC Pollution level 2: IEC CE Marking FCC Rule 96mm (W) 96mm(H) 115mm(D) Case depth: approx. 105 mm (when panel-mounted) 500 g 550 g ELEPON E.C.A.P. Corporation 10 Measuring Instruments 2
3 10-2. MODEL: EOM - 96 MODEL EOM-96 ±2,000mV: Resolution 1mV (in equivalent input) Contact Calibration hold feature Self-diagnosis Ambient environment Less than ±5mV 4 ma to 20 ma DC Input / Output isolated type Maximum load resistance: 900Ω range: Freely selectable within the measurement range 2 point (A1 A2) Storage ambient -25 to 65 Protective structure Conforming standards Relay contact: SPDT(1c) 240 V AC, 3 A and 30 V DC, 3 A (resistance load) Selectable from upper / lower limit operation (ON / OFF control) Select from "Abnormal warning" or "It is maintaining it." Sensitivity revision adjust: ±200mV span variable range: 50.0~150.0% Select from "Previous value hold" or "Optional value hold" or "Continuous" However, only the previous value hold is available in the mainttenance mode. Outside measurement range The converter is abnormal. -5 to 45 Relative humidity: 20% to 85% (without dew condensation) Rated voltage 100 V to 240 V AC, 50/60 Hz, 10VA (max.) Indoor-use panel installation type Panel case: ABS Terminal: PBT Panel: Dust and water proof structure Panel:IP65(IEC60529, JIS C0920) Rear case: IP20 Terminal: IP00 Class II equipment: IEC Pollution level 2: IEC CE Marking FCC Rule 96mm (W) 96mm(H) 115mm(D) Case depth: approx. 105 mm (when panel-mounted) 500g ELEPON E.C.A.P. Corporation 10 Measuring Instruments 3
4 10-3. MODEL: ERM - 96 MODEL ERM-96 Method for measurement: galvanic cell 0~2mg/L: Resolution 0.01mg/L Selectable from the indication of decimal one column or two columns (in equivalent input) Less than ±5mV 4 ma to 20 ma DC Input / Output isolated type Maximum load resistance: 900Ω range: Freely selectable within the measurement range Contact 2 point(a1 A2) Relay contact: SPDT(1c) 240 V AC, 3 A and 30 V DC, 3 A (resistance load) Selectable from upper / lower limit operation (ON / OFF control) Select from "Abnormal warning" or "It is maintaining it." Calibration hold feature Zero Quantity Calibration Span Calibration(Comparison proofreading with DPD tester) Select from "Previous value hold" or "Optional value hold" or "Continuous" However, only the previous value hold is available in the mainttenance mode. Self-diagnosis Ambient environment The proofreading is defective. Outside measurement range The converter is abnormal. Temperature: -5 to 45 Relative humidity: 20% to 85% (without dew condensation) Storage ambient -25 to 65 Rated voltage 100 V to 240 V AC, 50/60 Hz, 10VA (max.) Indoor-use panel installation type Panel case: ABS Terminal: PBT Panel: Dust and water proof structure Protective structure Conforming standards Panel:IP65(IEC60529, JIS C0920) Rear case: IP20 Terminal: IP00 Class II equipment: IEC Pollution level 2: IEC CE Marking FCC Rule 96mm (W) 96mm(H) 115mm(D) Case depth: approx. 105 mm (when panel-mounted) 500g ELEPON E.C.A.P. Corporation 10 Measuring Instruments 4
5 10-4. MODEL: EPC-100AC (in equivalent input) Range EPC-100AC ph: ph 0 to ph 14: Resolution 0.01pH ORP: ±2,000mV: Resolution 1mV ph: Less than ±0.05pH ORP: Less than ±5mV 4 ma to 20 ma DC: input / isolated type Maximum load resistance: 500Ω Straightness: 0.5% ph: ph 0 to ph 14, ph 0 to ph 10, ph 0 to ph 8, ph 2 to ph 12, ph 3 to ph 11, ph 4 to ph 14, ph 4 to ph 10, ph 6 to ph 14 ORP: ±2,000mV ±1,400mV ±1,000mV ±700mV The change chooses it with the DIG switch of the interior panel. Adjustment Control operation Calibration Contact Capacity Operation Set Range Control range hold feature The hold point of contact input that I am washing The 1c point of contact. 2CH independence 250 V AC. 3 A max. (Resistance load) Selectable from upper / lower limit operation (ON / OFF control) The change chooses it with the DIP switch of the interior panel ph: ph 0.00 to ph ORP: 0 mv to ±2,000 mv ph: ph 0.1 to ph 4.0 (ph ± 0.1 to ph ±2.0) ORP: 1mv to 999 mv (±1mv to ±499 mv) Automatic proofreading: 2 point Automatic potential stability judgment standardized solution ph 4, ph 7, (JIS) and ph 7, ph 9(JIS) Combination Manual proofreading: Differences more than arbitrary 2pH "Previous value hold","optional value hold","continuous" Selectable from the above The change chooses it with the DIP switch of the interior panel. 1a radio pressure welding point input. (It is transmission hold in point of contact ON) Measurements shift : ph: ph±2.00, ORP: ±200mV Time constant input filter reshuffling : "No time constant", "Time constant approximately 7 secon Error massage a: Error of the proofreading (Asymmetric electric potential, Sensitivity, Reply speed abnormal, Standard solution abnormal) b: Electrode diagnosis error (temperature sensor short circuit, Temperature sensor disconnection) c: Error out of the measurement range. (Full scale over, Full scale under) Ambient environment Temperature: -5 to 50 Relative humidity: Less than 85%RH Rated voltage 100 V to 115 V AC, 50/60 Hz, 7VA or 200 V to 240 V AC, 50/60Hz 7VA (It depends on appointment) Outdoor setting type: JIS CO920 Protection class 3 (rain proof type) Installation method Pole of 50A or Wall surface installation Case Polycarbonate (A resin color: White gray) Hood SPCC(color of the painting: DIC G262 equivalency) Fitting SUS mm(W) 186mm(H) 229mm(D) Do not include a fitting and a projection part 3kg ELEPON E.C.A.P. Corporation 10 Measuring Instruments 5
6 10-5. EPR Series MODEL ph recorder ORP recorder EPR-1S EPR-6S EPR-420S EPR-H200 (Hybrid type) 0 ph to 14 ph ±2,000 mv General precision ±1% (For a full scale) ±0.05% ±10 mv Input signal ph electrode 4 ma to 20 ma DC ph electrode Metal electrode Temperature compensation 0 to 100 Automatic or fixed resistance 500 Ω - 0 to Method Record width Electronic automatic equilibrium type 100mm Glass electrode-type mensuration Metal electrode-type mensuration Instructions speed Less than 5 second. (F S) Less than 3 second. (F S) Record method Speed of the chart felt-tip pen 10 mm/h, 20 mm/h, 40 mm/h (3 steps of gear change) Analog-style record: felt-tip pen Degital-style record: One color of ink ribbon wire dot method. Choose it among 41 kinds Warning 1upper limit circuit and 1 lower limit circuit - - 1upper limit circuit and 1 lower limit circuit "1a" 1 abnormal warning circuit "1a" AC 100V 50/60Hz AC 85~264V 50/60Hz Consumption electricity About 7VA 2kg About 35VA ELEPON E.C.A.P. Corporation 10 Measuring Instruments 6
} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).
ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,
More informationSPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION
ISO-400 ISO-900 SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER Model: ODM-36A FEATURES Microprocessor based 4-wire transmitter suitable for field installation. The unit features isolated inputs
More informationHYBRID RECORDER OUTLINE
Specifications Sheet No.SPEC-33E (st Edition) RM0C HYRID RECORDER OUTLINE RM0C is 00mm calibrated hybrid recorder in a 44x44 DIN front panel and short depth of 50mm case housing. The recorder has versatility
More informationSPECIFICATION SHEET. 2-WIRE TYPE ph ANALYZER/TRANSMITTER SYSTEM CONFIGURATION
ISO-14001 ISO-9001 SPECIFICATION SHEET 2-WIRE TYPE ph ANALYZER/TRANSMITTER Model: HDM-135A FEATURES 2-wire ph transmitter with built-in microcomputer: Field installation type ph analyzer / transmitter
More informationGeneral Specifications
General Specifications GS 77J04H0-0E Model MH Isolator (Free Range Type) General The MH is a plug-in type isolator that converts DC current or DC voltage signals into isolated DC current or DC voltage
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More informationMODEL: M2DYS SEN TRONIC AG
Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels
More informationSignet 9950 Dual Channel Transmitter
Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,
More informationMODEL: W2DYS SEN TRONIC AG. Mini-MW Series
MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters
More informationAdjustable Digital Process Instrument MDK480
Description The adjustable Digital Process Instrument MDK480 is designed to measure and display process variables in industrial applications.the instrument is panel mounted with front frame dimensions
More informationHigh-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals
Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationPaperless Recorder PR20
Technical Information TI 075R/24/ae Paperless Recorder PR20 Economical and time saving recorder operates without the need for paper or pens and is exceedingly simple to operate Application Areas Technological
More informationGeneral Specifications
General Specifications Model UT, UT Temperature Controller GS CE-E GENERAL UT series temperature controllers provide only the functions and size you require for your application. /6 DIN sizes is available.
More informationBASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter
Shimaden, Temperature and Humidity Control Specialists C %RH CP3701: Thermocouple Temperature Converter CP3702: R.T.D. Temperature Converter CP3703: mv DC-DC Converter CP3704: V/mA DC-DC-Converter CP3705:
More informationMaintenance: Check the measurement signal: regularly required once a month Calibration: typically 6 to 12 months after installation
The SMR digital transmitters have been developed especially for use in liquids for pressure, differential pressure, hydrostatic level and water quality measurement such as free chlorine, ph, ORP, temperature,
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More informationConductivity Transmitter N-LF V AC
OPERATING INSTRUCTIONS Conductivity Transmitter N-LF2000 230V AC These operating instructions apply to the following device: Article Measuring range Order number N-LF2000, Conductivity measuring device
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationTHM80X Series Industry degree high accuracy Temp. & humidity transmitter
THM80X Series Industry degree high accuracy Temp. & humidity transmitter Introduction IP65 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation
More informationSignet 9950 Dual Channel Transmitter
Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for Simplified Chinese, English, French, German
More informationµr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES
4365 & 4375 Recorders VIEW RECORDERS Splash and dust-proof door permits use even in poor environments. (Based on DIN 40050-IP54). Depth is a mere 220 mm, enabling significant instrument panel space savings.
More informationMINI MCR-SL-UI-I-LP-NC
2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationWDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system
CONDUCTIVITY TRANSMITTR WDM-A (-wire type) WDM-6A (-wire type) It is a type of small firm aluminum -electrode site-installation CONDUCTIVITY TRANSMITTR (signal transmitter) and easy operate. The device
More informationHigh-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals
Accessories Highquality digital indicator for panel mounting Model DI35M, with multifunction input Model DI35D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building
More informationDIGITAL PROGRAM CONTROLLER
KP1000 SERIES DIGITAL PROGRAM CONTROLLER The KP1000 series is a 96x96mm digital program controller with the indicating accuracy of ±0.1%, the control cycle of approximately 0.1 seconds and maximum 19 program
More informationGeneral Specifications
General Specifications GS J0X-0E Model MXT Universal Computing Unit (-input, Isolated -output Type) General This plug-in type universal computing unit receives DC current or DC voltage signals, applies
More informationGeneral Specifications
General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.
More informationSHIMADEN DIGITAL INDICATOR
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input
More informationDissolved Oxygen Transmitter
Dissolved Oxygen Transmitter OBM-67H The OBM-67H is a -wire type (4VDC power supply) dissolved oxygen transmitter housed in a robust, die-cast aluminum enclosure suitable for installation out in the field.
More informationGeneral Specifications
General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with
More informationP5201 Universal Programmable Transmitters with Galvanic Isolation
Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationAPPENDIX APPENDIX A 1
A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple
More informationGeneral Specifications
General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring
More informationAdvantages. Applications
3 s KH 250 General Data Rated input voltage 2 Vac Rated output voltage 2 Vac Rated power 250 VA Ambient temperature +40 C Degree of protection IP 40 Advantages Compensation for mains voltage fluctuations
More informationEasy-to-read in either English, French, or German; 20-digit, 2-line display; 6-channel simultaneous display possible
PHA & PHC STRIP CHART RECORDERS WITH BRILLIANT SIX-COLOR PRINTING Why use dot-matrix or fiber-tip pen printing when Fuji Electric s patented, cutting-edge recording technology offers an affordable inkjet
More informationDIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES
Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The
More informationIntegrated calibration system for electronic and pneumatic instrumentation model CBS-SC2000
Calibration technology Integrated calibration system for electronic and pneumatic instrumentation model CBS-SC2000 WIKA data sheet CT 92.32 Applications Calibration and testing of pneumatic and electronic
More informationPen-type DIGITAL MULTITESTER
BST-MT267 Pen-type DIGITAL MULTITESTER INSTRUCTION MANUAL Index 1. Introduction... 2. Safety Notes... 3. Features... 4. Specifications... 5. General... 6. Instrument Layout... 7. Measurement... 8. Maintenance...
More informationSection 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5
LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section
More informationGeneral Specifications
General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with
More informationGeneral Specifications
General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal
More information- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION
ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS
More informationGRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)
GRUNDFOS DATA BOOKLET Measuring amplifiers and controllers, preassembled systems Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP) Table of contents 1. Product introduction 3 measuring amplifier and controller
More informationGC83 Digital Indicators & GC93 Digital Meter Relay
Cat.No. B- GC83 Digital Indicators & GC93 Digital Meter Relay OUTLINE Model GC83 has been designed exclusively for indication. Model GC93 is equipped with a comparator like a relay and is applied to a
More informationSHIMADEN PROGRAM CONTROLLER
Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN PROGRAM CONTROLLER approved BASIC FEATURES Full multi-input and multi-range performance User selectable Thermocouple, RTD, V, mv and
More informationPA-850 PRESSURE TRANSDUCERS WITH AMP. PA R - N R2 FEATURES MODEL NUMBER DESIGNATION
INTERNAL STRUCTURE (R 1/4) 4 1 2 3 Part name Material 1 2 FEATURES 3 4 Stainless steel diaphragm ABS (Acrylonitrile butadiene styrene) + PC (Polycarbonate) High corrosion resistance and drip-proof construction
More informationGeneral Specifications
General Specifications GS J0U0-0E Model MU Universal Temperature Converter (Free Range Type) General The MU is a plug-in type universal temperature converter that converts input signal (thermocouple, RTD
More informationDIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS
Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback
More informationThough the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.
SERIES Ultra-compact Digital Panel Controller CA Convenient s packed in a small body! Ultra-compact Large display Flexible scaling Conforming to EMC Directive Ultra-compact size of W 48 H 24 D 65.5 mm
More informationCorporate Profile. needs and product demands. CON 08X /03 Rev 0
Corporate Profile A leader in the field of electrochemical instrumentation, Eutech Instruments is a dynamic company rapidly positioning itself globally as a leading manufacturer of electrochemical instrumentation
More informationGRUNDFOS ALLDOS DATA BOOKLET DIP. Measuring amplifiers and controllers Preassembled systems 50/60 Hz
GRUNDFOS ALLDOS DATA BOOKLET Measuring amplifiers and controllers Preassembled systems 50/60 Hz Contents Product features measuring amplifiers and controllers 3 -A preassembled systems 3 Identification
More informationInstallation and Operating Manual
GB Analog Weight Transmitter PS-1000 Installation and Operating Manual LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section
More informationMODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed
More informationTZIF 4. Current-to-Pulse Converter 10/ EN
TZIF 4 Current-to-Pulse Converter Conversion of direct current or voltage signals into a proportional pulse frequency Integration and average value formation of analog signals for quantity counting/remote
More informationMACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:
Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer
More informationMODEL AT-10 ANALOG TRANSMITTER
MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca
More informationMODEL: W2TS. Mini-MW Series
Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization
More informationPOINTAX 6000L2 Point Recorder
GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,
More informationTOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test
A new standard for Hipot & Insulation resistance testing Applied to World-Wide input voltage TOS5301 TOS5300 TOS5302 TOS5300(ACW) TOS5301(ACW/DCW) TOS5302(ACW/IR) New low-cost standard model that provides
More informationElectronic Thermostat TE-1 Version according to EN
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More informationTheta Hz. Technical Data Sheet. Special Features
Technical Data Sheet Theta Hz Theta Hz the transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent
More informationMODEL: 47LV. Digital Panel Meters 47 Series
Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display
More informationGeneral Specifications
General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent
More informationMODEL: MRP6. Final Control Elements
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic
More informationVIEW RECORDERS SPECIFICATIONS
SPECIFICATIONS Input points: µr1000:1,2,3,4,(pen),6(dot)point µr1800:1, 2, 3, 4, (pen), 6, 12, 18, and 24 (dot) point Input signals, range, and measurement range limits: Input RANGE Range 20 mv 20.00 to
More informationDial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator
Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis
More informationABB ph/orp analyzer and probe package
Water Technologies & Solutions fact sheet ABB ph/orp analyzer and probe package Series AX466 dual input analyzer description and use AX466 analyzers incorporate the latest technology to provide highly
More informationDPR100 C/D PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS
PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS EN0I-6021 06/2003 PRODUCT SPECIFICATION SHEET PRODUCT DESCRIPTION The DPR 100 C and D recorders are designed to meet the recording needs for most recording applications.
More informationFunctional data Factory settings Variable Settings
echnical data sheet Rotary actuator RF-MF(-O) Multifunctional rotary actuator with emergency control for and 3 way control ball valve orque Nm Nominal voltage AC/DC V Control: Modulating DC... V or variable
More informationEXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X
KOBO-pH Transmitter for ph-value and ORP Model APM-X measuring monitoring analysing EXPERT-LINE Measuring range: ph value: 0 to 14 ORP: -1500 to +1500 mv (0-100%) For general-purpose use with: Analogue
More informationMODEL: M2VF MODEL: M2VF [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type digital
More informationNRT 105: Electronic fan-coil controller, equiflex
Product data sheet 4.04 R 105: Electronic fan-coil controller, equiflex How energy efficiency is improved ECO Meter for displaying the current energy consumption and digital input for the change-over between
More information6/12/24 Dot Printing Model Smart Recorder SRF206/212/224
No. CP-SS-E // Dot Printing Model Smart Recorder SRF0// The Smart Recorder SRF 0// Dot Printing Model accepts DC voltage, thermocouple, resistance temperature detector (RTD), communications and ON/OFF
More informationAdvanced Paperless Recorder eco-graph a
Technical Information TI 097R/4/ae Advanced Paperless Recorder eco-graph a User friendly paperless recorder, for recording analog signals, counter values and quantities. Swift overview using the integrated
More informationJUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationGeneral Specifications
General Specifications µrs000 Recorders µrs000 recorders are compact recorder with 00mm recording width, available as standard in -pen, 2-pen, 3- pen, 4-pen, and 6-point dot-printing models. These recorders
More informationBOX TRANSDUCER TYPE CODE DESIGNATION
TYPE CODE DESIGNATION TYPE CODE DESIGNATION SMALL SIZED AC TRANSDUCER TT2-90A series (1) TT2 (2) A - (3) (1) Kind of input (2) Kind of outer case and its dimensions Mark A or AE V or VE W WV S P SP F Kind
More informationRecorders OUR MOST COMPACT CHART RECORDER! Input Number Chart Special Description Type of Pens Size Options Page
S E L E C T I O N G U I D E A VALUE-PRICED RECORDER WITH 1001 USES! OUR MOST COMPACT CHART RECORDER! OUR BEST SELLING CHART RECORDERS! PERFECT FOR FIELD! FLATBED CHART RECORDERS Input Number Chart Special
More informationMODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series
Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation
More informationGeneral Specifications
General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring
More informationMODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series
MODEL: 0VS-0 Hybrid IC Isolation Amplifiers 0 Series ISOLATION AMPLIFIER (-port isolation) Functions & Features Being used for printed wiring board installation High-linearity Low power consumption Isolating
More informationElectromagnetic flowmeters and switches DWM 1000/2000
KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationDUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER
OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com
More information1. BP4620 SPECIFICATIONS
1. SPECIFICATIONS 1. SPECIFICATIONS 1-1 1.1 Specification Conditions 1-2 1.2 Output 1-3 1.3 Output Limiters 1-5 1.4 Signal Sources 1-6 1.5 Monitor Output 1-7 1.6 Measurement Functions 1-7 1.7 Sequence
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications
More informationCOMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15
COMMERCIAL Bray Controls Commercial Diision 13788 West Road, Suite 200A Houston, Texas 77041 BCDSales@Bray.com Phone: 1-888-412-2729 Fax: 1-888-412-2720 www.braycommercialdiision.com GA Series - Actuator
More informationGeneral Specifications
General Specifications µrs800 Recorders GS0H0B0-00E µrs800 recorders are compact recorder with 80mm recording width, available as standard in,, 3, -pen, and 6,, 8, -point dot-printing models. These recorders
More informationLINAX 4000L Continuous-line recorder
-48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged
More informationMODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.
Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable
More informationUSER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2
(ENG) DECEMBER 2017 USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2 ISOLATOR - SIGNAL CONVERTER TYPE SP 11 CURRENT
More informationDISSOLVED OXYGEN TRANSMITTER
4 to 20 ma DISSOLVED OXYGEN TRANSMITTER Model : TR-DOT1A4 ATTENTION : Fill the Probe's Electrolyte at first. Intend to keep the DO probe under the best condition, when user receive the DIGITAL OXYGEN METER
More information