LINAX 4000L Continuous-line recorder
|
|
- Darcy McDaniel
- 1 years ago
- Views:
Transcription
1 / to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged design Applications The configurable continuous-line recorder LINAX 4000L serves to record slowly changing measured quantities. DC current and DC voltage can be connected directly. The recorder is meant for installation in panels. Description The LINAX 4000L is a microprocessor-controlled, continuous-line recorder. It is supplied with 1 to 4 line channels. The recorder is connected to transducers and is served to measure process-related signals. The recorder is supplied with signal inputs DC ma / V or DC ma. High electromagnetic compatibility (EMC) as well as high common mode and series mode rejection of interference voltages ensure non-problem use of the LINAX 4000L even in rough environments. Applied rules and standards A) International standards IEC 484 IEC IEC 664 IEC IEC IEC 529 IEC 801, EN EN IEC IEC 742 B) German standards DIN 4802 DIN 1624 DIN 481 Potentiometric recorders Safety requirements for electrical equipment for measurementontrol and laboratory use Overvoltage category, degree of pollution Mechanical stress (vibrations) Mechanical stress (shock) Degrees of protection provided by enclosures Immunity to interference of electromagnetic influences Radio interference suppression Climatic environmental conditions Isolating transformers and safety isolating transformers requirements Scales Recording paper Cases Symbols and their meaning Symbol X1n X2n X2n X1n Meaning Lower range limit nom. range Upper range limit nom. range Range span nom. range GOSSEN-METRAWATT GMBH
2 Technical data Analog inputs and measuring ranges DC current ma; Ri = 40 Ω ma; Ri = 50 Ω DC voltage ma; Ri = 500 kω Deadband Setting time Reference conditions Accuracy Variations Display 0.25 % of range span 2s, 5s, 20s, 60s Ambient temperature 25 C ± 1K Relative humidity % Auxiliary voltage Hn ± 2 %, nominal frequency ± 2% Mounting position Front upright ± 2 Warm-up time 0 min Deviation according to IEC 484 Temperature Humidity Scale One graduation per measuring system Scale face 5 mm wide Character size 2 mm Class 0.5 referred to range span 0.2 %/10 K, additionally Note influence on recording paper according to DIN 1624 Auxiliary voltage Hn 0.1 % at 24 V AC/DC ± 20 % 0.1 % at 24 V AC +10 % / 15 % 0.1 % at 115 V AC +10 % / 15 % 0.1 % at 20 V AC +10 % / 15 % AC interference voltages (see perm. interference voltages) 0.5 % of range span Magnetic field of external origin 0.5 mt 0.5 % of range span Mechanical stress according to DIN IEC /27 Transport Impact: 0 g/18 ms Vibration: 2 g/ Hz in function Vibration: 0.5 g/± 0.04 mm/ Hz/ 2cicli During and after the effect ± 0.5 % of range span Recording Arrangement of measuring systems and color correlation No. of line channels green rd channel red 2nd channel blue 1st channel violet 4nd channel Line recording Fiber recording pen with inkwell of approximately 1.4 ml, line length approximately 100 m, distance between the tips of the fiber recording pens 2 mm. Recording Chart speed Recording chart Visible chart length Recording width Chart intake (with roll chart) Auxiliary voltage 24 V AC/DC ± 20 % Power consumption with max. fitting approx. 15 W/20 VA 24/110/20 V AC +10 %/ 15 % Frequency range Hz Power consumption with max. fitting approx. 20 W/25 VA Climatic suitability Speed selectable on control panel: 1/5/10/20/60/120/00/600 mm/h 2 m roll chart or 16 m fanfold chart 60 mm 100 mm (chart width 120 mm, DIN 1620) Via automatic paper take-up device (daily tear-off or take-up of the 2 m possible) Ambient temperature C Transport and storage temperature C Relative humidity 75 % annual average; max. RH 85 % in function Climatic class K acc. to IEC GOSSEN-METRAWATT GMBH
3 Electrical safety Test according to DIN EN (classification VDE 0411) and/or IEC I Protection class I Overvoltage category III at the power input II at inputs Degree of pollution 2 in the device and at the connection terminals according to VDE 0110, parts 1 and 2 Test voltage.75 kv measuring channels to energy supply 2.20 kv protective conductor to energy supply Immunity to interference: test according to IEC 801 Type of test Test severity Variation Severity level ESD (1/0 ns) 6 kv HF field radiated 80 MHz... 1 GHz line-guided MHz Burst (5/50 ns) on Power line Test lead Surge (1,2/50 µs) on Power line common differential 1 MHz pulse on Power line common differential 10 V/m 10 V/m 2kV 1kV 2kV 1kV 2kV 1kV The NAMUR industry standard EMC is met (Interface cables shielded). 2 Functional extra low voltage with protective separation (PELV) Between power input measuring channels, control leads, interface cables acc. to VDE 0100 part 410 and VDE 0106 part 101. Electromagnetic compatibility The protection goals of the EMC directive 89/6/EWG as to radio interference suppression according to EN and as to immunity to interference according to EN are complied with. Radio interference suppression Limit class B according to EN or Post decree 24/92. Permissible interference voltages Test Type Series mode interf. voltage Peak-peak Push-pull rejection Common mode interference voltage Common mode rejection Scope of delivery Permissible interference 0. meas. span max. V 5 db 60 V DC /250 V AC 8 db for DC / 96 db for AC 1 copy of operating instructions 2 fasteners 1 chart roll or fanfold pack, inserted in the unit 1 fiber recording pen per measuring channel Additionally, depending upon the order: Centering angle bracket for installation in mechanical grids; reading ruler(s) GOSSEN-METRAWATT GMBH
4 Connection, case and installation Electrical connections Protection type IP 20 Screw and plug terminals for signal inputs Max. wire cross section 2 x 1 mm 2 Screw terminals for line connection Max. wire cross section 4 mm 2 Case Molded material for installation in panels or mechanical grids (see dimensional drawing for dimensions) Protection type of case according to IEC 529 Front panel IP 54 Rear panel IP 20 Position of use Lateral [ ], inclined to the rear 20, to the front 20 Mounting distance Horizontal or vertical 0 mm, it must be possible to open the door of the case through 100 Weight kg, approx. Dimensional drawing (dimensions in mm) Color of case Silica-gray according to RAL 702 Door of case Molded material or door with metal frame RAL 702 and glas pane, anti-glare Fastening of case With 2 fasteners (optionally for installation in panel or mechanical grid), centering angle brackets are required for installation in mechanical grids Panel cutout Wirung diagrams Signal inputs 4 GOSSEN-METRAWATT GMBH
5 Order code (cont.) Descrizione LINAX 4000L with identical DC measuring ranges for all channels A4150 Front dimensions mm 1 line channel AA001 2 line channels AA002 line channels AA00 4 line channels AA004 Meas. ranges DC ma, selectable DC V Lower range limit X1 Upper range limit X2 X1 = 0 ma X2 = 20 ma BA001 Meas. ranges DC ma X1 = 4 ma X2 = 20 ma BA002 Scale 1st channel: same as measuring range BB001 without graduation BB BB00 as per request BB900 Reading ruler 1st channel: without reading ruler BC000 same as scale BC BC002 as per request BC900 Scale 2nd channel, only for 2-channel or multi-channel versions: same as scale 1st channel, but markings CB... Reading ruler 2nd channel, only for 2-channel or multi-channel versions: same as 1st channel, but markings CC... Scale rd channel, only for -channel or 4-channel version: same as scale 1st channel, but markings DB... Reading ruler rd channel, only for -channel or 4-channel version: same as 1st channel, but markings DC... Scale 4th channel, only for 4-channel version: same as scale 1st channel, but markings EB... Reading ruler 4th channel, only for 4-channel version: same as 1st channel 1, but markings EC... CBxxx CCxxx DBxxx DCxxx EBxxx ECxxx Recording type for roll (2 m) KA001 for fanfold pack (16 m) KA002 Auxiliary voltage: AC: 21 V V V LA001 AC: 98V...115V V LA002 AC: 196 V V V LA00 DC/AC: 20 V V V LA004 (Cont d next page) GOSSEN-METRAWATT GMBH 5
6 Order code (cont.) Descrizione A4150 Front door Plastic MA001 Metal MA002 Label Blank with GOSSEN-METRA- WATT logo Blank without logo With inscription as per request, 1 line/meas. point with max. 1 characters NA000 NA001 NA900 Test protocol None PA000 With factory certificate according to DIN PA001 Operating instructions German RA000 None RA001 English RA002 French RA00 Italian RA004 Ordering examples Clear text Ordering code LINAX 4000L with identical DC meas. range for all channels A4150 continuous-line recorders AA00 Meas. range DC ma BA001 Scale 1st channel: BB00 Scale 2nd channel: MW CB900 Scale rd channel: C DB900 Recording type for fanfold pack (16 m) KA002 Auxiliary voltage AC: 20 V LA00 Front door Plastic MA001 Ordering code: A4150 / AA00 / BA001 / BB00 / CB MW / DB C / KA002 / LA00 / MA001 6 GOSSEN-METRAWATT GMBH
7 Accessories s ending with a letter are complete and need not to be commented. s ending with a numeral must be commented with the following markings. Description Scale without graduation, beginning and end marked Scale, graduation as per request Graduation: A410A A410 AA900 Reading ruler, graduation as per request Graduation: A4120 AA900 Label for measuring point with GOSSEN-METRAWATT logo without GOSSEN-METRAWATT logo Channel green without inscription Channel green with inscription Channel red without inscription Channel red with inscription Channel blue without inscription Channel blue with inscription Channel violet without inscription Channel violet with inscription A4110 AA000 AA001 BA001 BA900 BB001 BB900 BC001 BC900 BD001 BD900 Screw terminal with 5 connectors Screw terminal with connectors A404A A404B 4 each centering angle (with installation in grid) A416A Consumable items (cont d) s ending with a letter are complete and need not to be commented. s ending with a numeral must be commented with the following markings. Description Recording chart, chart width 120 mm, recording width 100 mm Chart roll 2 m, graduation , minimum ordering quantity 25 rolls Time graduation/ speed None A401A 10 mm/h A401B 20 mm/h A401C 60 mm/h A401D 120 mm/h A401E Chart roll 2 m, graduation , minimum ordering quantity 25 rolls A4070 Time graduation/ speed as per request CA900 (cont d) GOSSEN-METRAWATT GMBH 7
8 Consumable items (cont d) s ending with a letter are complete and need not to be commented. s ending with a numeral must be commented with the following markings. Description Chart roll 2 m, with calibrated graduation, minimum ordering quantity 25 rolls A4071 Calibrated graduation as per request AA900 Inscription as per request BA900 Time graduation/ speed as per request CA900 Fanfold pack 16 m, graduation , minimum ordering quantity 25 packs Time graduation/ speed None A401L 10 mm/h A401M 20 mm/h A401N 60 mm/h A401P 120 mm/h A401Q Fanfold pack 16 m, graduation , minimum ordering quantity 25 packs A4075 Time graduation/ speed as per request AA900 Fanfold pack 16 m, with calibrated graduation, minimum ordering quantity 25 packs A4074 Calibrated graduation as per request AA900 Inscription as per request BA900 Time graduation/ speed as per request CA900 Recording styli Stylus green Stylus red Stylus blue Stylus violet A406B A406A A406C A406D Printed in Germany Subject to change without notice GOSSEN-METRAWATT GMBH Thomas-Mann-Str Nürnberg, Germany Phone Fax
Overcurrent Protection / 7SJ45
Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers
MINI-PS AC/24DC/1.3
Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics
Light-strip indicator
/2 s /2 PROLUX 96 x 24 mm with 5 segments, /6 PROLUX 144 x 24 mm with 101 segments, /10 PROLUX 144 x 6 mm with 71 segments, Siemens MP 12 200 PROLUX 96 x 24 mm with 5 segments, Design The PROLUX light-strip
Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
T22. Torque transducer. Special features. Data sheet
T22 Torque transducer Special features - Nominal (rated) torques 0.5 Nm, 1 Nm, 2 Nm, 5 Nm, Nm, Nm, 50 Nm, 0 Nm, 0 Nm, 500 Nm and 1 knm - Nominal (rated) rotational speed up to 000 rpm (depending on measuring
SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar
For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output
Electronic timer CT-SDD.22
CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W
TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs
Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet
1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet
2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection
Analog signal converters CC range
Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally
Electronic timer CT-MFS.21
2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the
KINAX SR 719 Programmable Transmitter for Position Feedback
Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 719 (Figs. 1 and 2) is used to measure and transmit linear displacement (stroke) on various types of
Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)
Passive Current Transducers for Sinusoidal Alternate Currents From 0... A/0...5 A (-SW) Passive current transducer without power supply Measuring range A and 5 A AC, reconnectable Available with threshold
T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en
T10FS Torque Flange Data Sheet Special features Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm, 10 knvm Nominal speed from 12,000 rpm to 24,000 rpm Low rotor weights
T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en
T40FM Torque flange Special features Data Sheet - Nominal (rated) torque: 15 kn m, 20 kn m, 25 kn m, 30 kn m, 40 kn m, 50 kn m, 60 kn m, 70 kn m and 80 kn m - Nominal (rated) rotational speed up to 8000
IRI1-ER - Stabilized Earth Fault Current Relay. Manual IRI1-ER (Revision A)
IRI1-ER - Stabilized Earth Fault Current Relay Manual IRI1-ER (Revision A) Woodward Manual IRI-ER GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2
echnical data sheet LR4A-SR Modulating rotary actuator for and -way control ball valves orque Nm Nominal voltage AC/DC 4 V Control: Modulating DC... V Position feedback: DC... V echnical data Safety notes
Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
XP2-R Power and Reverse Power Relay
XP2-R Power and Reverse Power Relay Manual XP2-R (Revision C) Woodward Manual XP2-RE Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward
4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards
ALPHA 630 - DIN Floor- Mounted Distribution Boards /2 Introduction Unequipped Distribution Boards /5 8GK1 surface-mounting distribution boards, IP3 /6 8GK1 surface-mounting distribution boards, IP55 Marshaling
XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)
XP2-R Power and reverse power relay (January 2006) Manual XP2-R (Revision New) Woodward Manual XP2-R GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E
Current monitoring relays CM-SRS.1 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from
MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable
MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable 1. Short description configurable inputs and outputs signal conversion/amplification 3-way-isolation zero/span adjustment 17.5 mm ME housing
METRAHit 30M Precision Digital Multimeter
3-348-979-03 5/3.03 Precision multimeter (V, ma, Ω, Hz, C/ F) and data logger 1,200,000 digit display range High resolution for: DC/AC+DC voltage: 100 nv/1 µv DC and AC+DC Current: 100 pa TRMS AC+DC Milliohmmeter
STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features
Uninterruptible power supply Data sheet 105623_en_00 PHOENIX CTACT 2013-06-07 1 Description Uninterruptible power supply units continue to deliver power even in the event of mains breakdowns or failures.
BML-S1F_-A/Q _-M _-_0-KA Magnetic Linear Encoder System. User's Guide. Magnetic Linear Encoder System BML-S1F_-A/Q _-M _-_0-KA
User's Guide BML-S1F_-A/Q _-M _-_0-KA Balluff GmbH Schurwaldstraße 9 73765 Neuhausen a.d.f. Deutschland Tel. +49 7158 173-0 Fax +49 7158 5010 balluff@balluff.de www.balluff.com 1 Table of Contents 1 Safety
Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters
Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel
ARCO 400. Technical Data
Technical Data OMICRON electronics GmbH 2017. All rights reserved. This technical data was extracted from the following manual: ENU 1119 04 03 All rights including translation reserved. Reproduction of
TR 104, TR 104-Ex Rail mounted Temperature Transmitters
Data Sheet 10/-8.48-EN Rev. A TR 104, TR 104-Ex Rail mounted Temperature Transmitters Analog, Pt 100 (RTD), fixed measuring ranges Input Resistance thermometer (two-wire and three-wire circuit) Optionally
Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
VariTrans P D1 TRMS
Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings VariTrans P 41000 D1 TRMS VariTrans P 41000 TRMS AC/DC High-Voltage Transmitters With True
High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime
Issued: 5.06.999 Status: 5.06.999 Version: B/09..00 Data subject to change without notice Features Overvoltage and undervoltage protection Single- or three-phase operation High-set overvoltage stage with
QUINT-PS/ 3AC/24DC/40
Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum
Transformer differential protection
Transformer differential protection Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970883) Features Three phase differential protection with two, three, five or
Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile
Temperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description
Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals
Power supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing
echnical data sheet Rotary actuator LR4A Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage AC/DC 4 V Control: Open/close or -point echnical data Electrical data Nominal voltage
MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description
Universal current transducer Data sheet 104059_en_05 PHOENIX CONTACT 2011-03-09 1 Description MCR-SL-CUC-...-I and MCR-SL-CUC-...-U active current transducers convert DC, AC, and distorted currents into
Digital Indicator DS 96/24
Data Sheet 10/33-2.11-EN Digital Indicator DS 96/24 This indicator is suitable for measuring direct voltage or direct current. By using potentiometers, the digital display can be assigned to any input
Three-phase monitoring relay CM-PFS
Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available
For non-electrical quantities
Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data
Inductive Standard Displacement Transducers
WA Inductive Standard Displacement Transducers Special features - Available as displacement probe or with detachable plunger - Good thermal stability in the event of temperature gradients - Space saving,
Process display RIA 261
Technical Information TI 083R/24/ae Process display RIA 261 Digital loop powered field display for 4 to 20 ma current loops Features and Benefits Loop powered display, no additional power supply cable
PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system
TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples
RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal
MCR-T-UI(/NC) MCR-T-UI-E(/NC)
MCR-T-UI(/) MCR-T-UI-E(/) Programmable Temperature Transducers for Resistance Thermometers and Thermocouples INTERFACE ata Sheet 00_0_en PHOENIX CONTACT - 0/00 escription A universal temperature measuring
Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE
Digital Panel Meter K3TE Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display with
ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
SINEAX TV809, 1 channel Programmable Isolating Amplifier
For electrically insulating, ampliflying and converting DC signals 0102 II (1) Ga II (1) Da Application The purpose of the isolating amplifi er SINEAX TV809 (Fig. 1) is to electrically insulate input and
P331-2 set ESD generator (IEC )
User manual Probe set set ESD generator (IEC 61000-4-2) Copyright January 2017 LANGER GmbH 2017.01.09 User manual Table of contents: Page 1 ESD generator (IEC 61000-4-2) 3 1.1 Design and function of the
Multi-voltage Multi-function. Wiring diagram (without control signal)
80 Modular timers 16 A 80 Multi-function and mono-function timer range 80.01T - Multi-function & multi-voltage 80.11T - On-delay, multi-voltage Complies with EN 45545-2:2013 (protection against fire of
QUINT-PS/ 1AC/24DC/20
Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system
Miniature circuit-breakers S 280 UC series. System pro M. Technical data
Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum
Current monitoring relays CM-SRS.2 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter
Features Regulated Converter Description 5W Class II power supply in compact 1 x 1 Package (high power density) Internal EMC class B filter UL/IEC/EN695-1 certified UL/IEC/EN62368-1 certified Electrical
JUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3039 Fulda, Germany Postal address: 303 Fulda, Germany Phone: 49 1 0030 Fax: 49 1 00307 email: mail@jumo.net Internet: www.jumo.net JUMO Instrument
DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER
OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com
It s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P TRMS series. Isolation Amplifiers.
It s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P 40000 TRMS series Isolation Amplifiers Isolation Amplifiers A Class of Its Own. AC/DC High-Voltage With True
Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions and 10 time ranges.
electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en
C l i p electronics Industrial Amplifier Data Sheet Special features Amplifier and additional units for strain gauge full bridges and inductive half and full bridges Modules for mounting onto support rails
DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions
Isolators, Isolator / Power Supplies Operating Instructions EN Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized
prosonic T FMU230, FMU231
Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters
METRA HIT 22 26S/M Analog-Digital Multimeters with Signal Generator
3-349-026-03 10/8.06 METRA HIT 22/23/24/25/26 Precision multimeter (V, db, Ω, F, Hz, C/ F, V ) Resolution: 10 μv, 10 mω Integrated quartz movement for MIN-MAX recording with reference to real-time Rectangular
02/11/2015
Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions
Digital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
XN2 - Mains decoupling relay. Manual XN2 (Revision C)
XN2 - Mains decoupling relay Manual XN2 (Revision C) Woodward Manual XN2 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by Woodward
PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks
GB Technical data Issue 06/2009 PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks Fault detection Evaluation of voltage quality according to EN50160 and IEC61000-2-2 Fault recorder
JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO
SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke
s 4 501 ACVATIX Electromotoric actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10 V, 4 20
1715 Redundant I/O System Specifications
Technical Data 1715 Redundant I/O System Specifications System Module Catalog Numbers 1715-AENTR, 1715-IB16D, 1715-OB8DE,1715-IF16, 1715-OF8I Base Unit Catalog Numbers 1715-A2A, 1715-A3IO Termination Assembly
Time over/underfrequency relay with protection assemblies
Time over/underfrequency relay with protection assemblies RXFK 2H and RAFK 509 009-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970104) (SE970108) Features
Electronic timer CT-SDE
CDC 51 059 F000 1 Characteristics " 1 single time range from 0. to 0 s " versions with different supply voltage ranges are available: 4 AC/DC and 110-10 AC and 80-415 AC " Single-function timer with star-delta
PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description
Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer
Isolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
XM Monitoring Modules Specifications
Technical Data XM Monitoring Modules Specifications Catalog Numbers 1440 series The XM series of intelligent I/O modules process, in real-time, the critical parameters used to assess the current health
Electronic measuring and monitoring relays CM-range
Electronic measuring and CM-range Content Benefits and advantages CM range, function overview... 30 Selection and ordering details Current and voltage monitors, single phase... 33 Three phase monitors...
R&S ZNC Vector Network Analyzer Specifications
ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement
ALPHA DIN Wall-Mounted. Distribution Boards
Siemens AG 008 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quick-assembly kits Unequipped
Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers
Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.
LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.
99 PHOTO PHOTO LED Beam Sensor - SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.~ CA... P.79 ~ General precautions... P.7 Conforming to EMC Directive
1715 Redundant I/O System Specifications
Technical Data 1715 Redundant I/O System Specifications System Module Catalog Numbers 1715-AENTR, 1715-IB16D, 1715-OB8DE,1715-IF16, 1715-OF8I Base Unit Catalog Numbers 1715-A2A, 1715-A3IO Termination Assembly
02/11/2015
"Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue
MasterINTERFACE 39 Series - Relay interface modules
Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic clip Dual screw head (blade+cross)
Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B
Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B AC switching Solid State Relay Switching through back to back thyristors Long
PROFiTEST C Test Instrument per DIN VDE /8.14
3-349-075-03 16/8.14 Testing of Residual-Current Devices (RCDs) Measures contact voltage without tripping the RCCB. Contact voltage relative to nominal residual current is measured with 1 / 3 nominal residual
Controller for the Implementation of a Central or Decentralized Electrohydraulic System
EFX 1624m Electronic Controller Programmed with Eaton CONTROL F(x) Software to IEC 61131-3 Standard 2nd CAN interface for gateway function according to SAE J1939 Supply voltage 10...32V DC Technical Data
General Specifications
General Specifications Model UT, UT Temperature Controller GS CE-E GENERAL UT series temperature controllers provide only the functions and size you require for your application. /6 DIN sizes is available.
This data sheet is only valid in association with the IL SYS INST UM E user manual.
Inline counter terminal, version for extreme conditions, 1 counter input, 1 control input, 1 output, 24 V DC, 500 ma Data sheet 106148_en_03 PHOENIX CONTACT 2015-11-04 1 Description The terminal is designed
Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease
Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality
WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany
522 WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany WAGO Products: WAGO-I/O-SYSTEM with ETHERNET Controllers, DALI and EnOcean Components Wireless Technologie System Overview 524
Network Analyzer for Low-, Medium- and High-Voltage Networks
Technical data Network nalyzer for Low-, Medium- and High-Voltage Networks Model PQ-Box 150 1 Fault detection 1 Evaluation of voltage quality according to EN50160 and IEC61000-2-2 (2-4) 1 FFT nalysis up
For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer ITL 4000-S I PN = 4000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I > 0 P Features Closed
Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet
2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer