Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture

Size: px
Start display at page:

Download "Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture"

Transcription

1 015 Pure Lighting. All Rights Reserved. Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH-ARE3 & AH-ASE W. Fullerton Ave Chicago, IL Tel: Fax: info@purelighting.com General Information Fixture must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. Compatible only with traditional, level 5 surface finishing, not self-leveling, PVA primer systems. Not for use in wood or tile ceilings. Fig.1 Complete Fixture 6 1/16" (154mm) HOUSING ANCHOR SCREENS WORKFLOW CHART 1. Locate and mount housing. Screw and lock-in housing 3. Connect wires un housing 5 7/8" (149mm) 18 1/" (470mm) 8 7/8" (5mm) 1 1/8" (307mm) PLASTER PLATE CONTRACTOR 1. Install and cut drywall around housing. ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP. 1. Adjust plaster flange frame and tighten wing nuts.. Connect the MR16 and LEDS wiring to the plaster plate. 3. Screw plaster plate into housing. 4. Test MR16 and LEDs. CONTRACTOR 1. Plaster, sand & paint.. Clean aperture with clean damp towel. TILT GEAR Fig. Pan tilt Mechanism attached to inside of plaster plate. BACK LIGHT SHIELD HOT AIMING WITH PHILLIPS SCREWDRIVER PAN LOCK PAN ROTATION RING 1. Clean aperture with clean damp towel, where the drywall contractor missed.. Adjust pan rotation ring and aim lamp. You're done! Important Scan with your mobile device to watch the installation video or visit a-install Importante Escanear con el dispositivo móvil para ver el video de instalación o visite a-install HOT AIMING TILT SCREW Fig.3 Snoot Assembly LIGHT SPILL SHIELD 5 BULLET CATCHES SNOOT RETAINING RING LOCKING RING (INCLUDED) MR16 HALOGEN LAMP ONLY LOCKING RING (INCLUDED) SOFT FOCUS LENS (INCLUDED) LENS (OPTIONAL) LOUVER (OPTIONAL) SNOOT LAMP HOLDER 1

2 A ANCHOR SCREENS 1 5 7/8" (149mm) 14 3/4" (375mm) 8 7/8" (6mm) ALIGNMENT NOTCH C REMODEL NOTE: CUT TO MIDDLE OF JOIST. NOTE: APERTURE IS CENTERED WITH CURVES IN HOUSING. ALIGNMENT NOTCH 1 1/8" (308mm) 3 1: Use these dimensions when locating the center point of the aperture during the installation process. Align the fixture using a laser or a chalk line. NOTE: Drywall anchor screens may be removed, if the joist are less than 14 1/" apart. Refer to page 8 to shorten the hanger bars, 3: After fixture is positioned, tighten all (10) screws on hanger bars. B D NOTE: APERTURE IS CENTERED WITH CURVES IN HOUSING. (NOT CENTER IN FIXTURE) 4 MUST BE FLUSH WITH JOIST : Hanger bars must align and remain flush with joist. 4: After installation, pull on fixture to ensure there is no movement.

3 E LINE INPUT 10V - 40V INSIDE AURORA JUNCTION BOX (NOT TO SCALE) - Neutral TO NEXT FIXTURE + Dimmable Switchleg *NOTE* Leave 1" of wire in the junction box for future maintenance through the f ixture aperture. Make sure the wires nut connections are tight. MAGNETIC LOW VOLTAGE DIMMER INSIDE AURORA FIXTURE 10V 75W MAGNETIC TRANSFORMER (40V ELECTRONIC TRANSFORMER FOR EUROPE) MR16 LAMP WIRING DIAGRAM FOR USE WITH PURE LIGHTING AURORA NON-RGB FIXTURES 3

4 CONTRACTOR F H CUTOUT 7 9 PLASTER FLANGE FRAME ROTARY TOOL LOOSEN WINGNUTS TO ADJUST PLASTER FLANGE FRAME 7: Drywall contractor must install drywall and cut 14 3/4" (375mm) X 1 1/8" (308mm) hole with rotary cutting tool around fixture or pre-cut hole in drywall prior to installation. Contratista hojas de pared tiene que instalar la hoja de pared y corte un aqujero 14 3/4" (375mm) X 1 1/8" (308mm) con une corte rotatorio alrededor el enseres fijo o lo corte un agujero antes que instalar. 9: Loosen (4) wing nuts and adjust plaster flange frame to be flush with drywall. All 4 corners MUST be exactly even with drywall. Plaster flange frame adjusts to accommodate 1/" (13mm) to 1 1/4" (3mm) ceiling thickness. G ANCHOR SCREEN I CEILING 8 ANCHOR SCREW 8: Electrian must anchor drywall anchor screens. Insert screws through drywall into anchor screen on fixture : Use a straight edge or level and move plaster flange frame up or down to be exactly even with drywall ceiling. 4

5 J TIGHTEN WINGNUTS TO ADJUST PLASTER FLANGE FRAME 11 L : Tighten (4) wing nuts securely. 13: Loosely attach plaster plate using all (4) screws. After all (4) screws are started, go back and tighten the screws securely. K M LED QUICK CONNECTOR USE A PEN TO TIGHTEN LOCKING RINGS. 10 LAMP LOCKING RING LOUVER AND LENS LOCKING RING 14 SNOOT LAMP HOLDER 10: Electrician must anchor drywall anchor screens. Insert screws through drywall into anchor screen on fixture. 14: Check to ensure that the plaster plate is flush and even with the drywall. 5

6 N P RED, GREEN AND BLUE LED UPLIGHT, MAKE SURE ALL THREE LED'S ARE WORKING. MR16 HALOGEN ACCENT LIGHT (NO MR16 LED) RED, GREEN AND BLUE LED UPLIGHT, MAKE SURE ALL THREE LED'S ARE WORKING. HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE 15: Turn on and test MR16 and LEDs to ensure they are properly installed. 17: Tilt and rotate MR16 as needed. When lamp is properly adjusted secure pan lock. O Q OPEN SPACE ON RACK 18 GEAR COVER TOP CLIP HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE BOTTOM CLIP 18: Measure the distance of the open space on the track. 16: To aim lamp, loosen pan lock, rotate and position the pan rotation ring. 19: Remove the protective film from the gear cover. 0: Cut the gear cover to fit the space if necessary. 6

7 R APERTURE T 1 5 RACK GEAR COVER GEAR COVER RACK PAINT OVER PAINT SHIELD. REMOVE PAINT SHIELD 0-60 MINUTE AFTER PAINTING. PINTAR SOBRE EL PROTECTOR DE PINTURA REMOVER EL PINTURA 0-60 MINUTOS DESPUES DE PINTAR. 1: Insert the gear cover (make sure the gear cover clips are facing the lamp assembly rack) from the bottom of the aperture. 5: Paint (Pintar). : Secure by snapping in the two bottom clips of the gear cover first to the bottom edge, then snap in the top two clips to the top edge. S CONTRACTOR Compatible only with traditional, level 5 surface finishing, not self-leveling, PVA primer systems. APPLY A THIN LAYER OF DURABOND 45 COMPOUND AROUND ALL FOUR SIDE. DO NOT USE TAPE. DO NOT USE PVA PRIMER SYSTEMS. APLICAR UNA CAPA DELGADA DE DURABOND 45 ALREDEDOR DE LOS CUA 3 MAKE SURE THE SHIELD IS IN PLACE. (ASEGURASE QUE EL PROTECTOR DE PINTURA ESTES PUESTO.) U REMOVE ANY EXCESS PAINT THAT IS ON THE BEVELED EDGE. ANY EXCESS PAINT WILL BE NOTICEABLE WHEN LIGHT IS POWERED ON. WIPE INSIDE OF APERTURE WITH CLEAN DAMP TOWEL. (REMOVER CUALQUIER EXCESO DE PINTURA. CUALQUIER EXCESO DE PINTURA SERA NOTABLE CUANDO LA LUZ ESTA ENCENDIDO. LIMPIE ADENTRO DE LA APERTURA CON UNA TOALLA LIMPIA Y HUMEDA). SAND AND PLASTER AGAIN, UNTIL SMOOTH FINISH IS ACHIEVED. LIYAR Y YWSO OTRA VES HASTA QUE SUPERFICIE ESTES COMPLETAMENTE LISO. 4 CLEAN INSIDE OF FIXTURE WITH COMPRESSED AIR TO REMOVE ANY REMAINING CONSTRUCTION DEBRIS. (LIMPIA ADENTRO DE ENSERES FIJO CON AIRE COMPRIMIDO PARA REMOVER CUALQUIER POLVO QUE HALLA QUEDADO ADENTRO). 6 3: Plaster (Yeso). 6: Clean Area. 4: Sand (Liyar). 7

8 V X HANGER ARM HOUSING 7 HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE HANGER ARM : Pull the hanger arms completely out of the housing. 3: Break the ends completely off hanger arms. 7: Wash hands and clean all drywall residue from inside aperture, with a clean damp towel. Electrician or lighting designer - ensure pan rotation ring is adjusted, locked in place, and the lamp is aimed properly. SHORTENING THE HANGER BARS (ONLY FOR JOISTS SPACED LESS THAN 14.5") W HOUSING Y HOUSING HANGER ARM 1 1 HANGER ARM 1 1 ANCHOR SCREEN 4 4 PHILLIPS SCREW 1: Remove the four Phillip screws on the housing to remove the two anchor screens, and put the screws back on. 4: Insert the hanger arms back into the housing, and continue to step A on page to complete instillation. 8

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH3-ARE3-RGB & AH3-ASE3-RGB. Fig.

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH3-ARE3-RGB & AH3-ASE3-RGB. Fig. 0 Pure Lighting. All Rights Reserved. Installation Instructions For Aurora Halogen Accent Housing Round & Square Trimless AH-ARE-RGB & AH-ASE-RGB W. Fullerton Ave Chicago, IL 606 Tel: -0-95 Fax: -95-56

More information

AURORA HALOGEN ACCENT HOUSING 3 ROUND AND SQUARE TRIMLESS AH3-ARE3-RBG & AH3-ASE3-RGB INSTALLATION INSTRUCTIONS

AURORA HALOGEN ACCENT HOUSING 3 ROUND AND SQUARE TRIMLESS AH3-ARE3-RBG & AH3-ASE3-RGB INSTALLATION INSTRUCTIONS AURORA HALOGEN ACCENT HOUSING 3 ROUND AND SQUARE TRIMLESS AH3-ARE3-RBG & AH3-ASE3-RGB INSTALLATION INSTRUCTIONS Fixtures must be installed by a qualified electrician (check with local and national codes

More information

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture 015 Pure Lighting. All Rights Reserved. Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH-ARE3 & AH-ASE3 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1195

More information

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB. Fig.

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB. Fig. 2015 Pure Lighting. All Rights Reserved. Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB 1718 W. Fullerton Ave Chicago, IL 60614

More information

Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3" Fig.1 Complete Fixture ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP PAN LOCK

Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3 Fig.1 Complete Fixture ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP PAN LOCK 2015 Pure Lighting. All Rights Reserved. Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3" 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1195 Fax: 773-935-5613 www.purelighting.com

More information

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing 90ENTRA EN_-LH9_. LED - ROUND/ SQUARE GENERAL PRODUCT I NFORMATION: This product is safety

More information

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims Installation Instructions for 90ELED-WIC Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims LED E_L_-L_WI. LED - ROUND/ SQUARE FLANGELESS GENERAL PRODUCT I NFORMATION: This product

More information

Installation Instructions For TruLine 1.6A 24VDC

Installation Instructions For TruLine 1.6A 24VDC 2014 Pure Lighting. All Rights Reserved. Installation Instructions For TruLine 1.6A 24VDC INS# 902-TL1.6A-07 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1195 Fax: 773-935-5613 www.purelighting.com

More information

Round or Square Chicago Plenum Down Light Housing with Lamp

Round or Square Chicago Plenum Down Light Housing with Lamp Installation Instructions for 90ELED-DCP Round or Square Chicago Plenum Down Light Housing with Lamp LED E_-L_DC. LED - ROUND/ SQUARE GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations.

More information

INSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10

INSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10 IMPORTANT SAFETY INSTRUCTIONS 1. Read all instructions before installing. 2. System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations.

More information

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations. Installation Instructions for 90EMULTI Multiples EM_. GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations. This product can be dimmed with a standard electronic dimmer or a 0-0V

More information

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4 Installation Instructions for 90ELED-DIC Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E_L_-L_DI. LED - ROUND/ SQUARE FLANGELESS GENERAL PRODUCT I NFORMATION: This product

More information

Lightplane 3.5 Recessed

Lightplane 3.5 Recessed INSTALLATION INSTRUCTIONS Lightplane 3.5 Recessed LP3.5R Recessed Ceiling IMPORTANT SAFETY INSTRUCTIONS When installing or using this fixtures basic safety precautions must be followed. Read all instructions

More information

Installation Instructions for TruLine 1.6A 24VDC. Section One: Basic Configuration Options

Installation Instructions for TruLine 1.6A 24VDC. Section One: Basic Configuration Options Doc # 902-TL1.6A_07 1718 W. Fullerton Chicago, IL 60614 Ph: 773.770.1195 Fax: 773.935.5613 www.pureedgelighting.com info@pureedgelighting.com 2016 PureEdge Lighting. All Rights Reserved. Installation Instructions

More information

2. Connect driver to power source leads. After connections are made, place driver above ceiling. SEE MINIMUM SPACE REQUIREMENTS BELOW.

2. Connect driver to power source leads. After connections are made, place driver above ceiling. SEE MINIMUM SPACE REQUIREMENTS BELOW. INSTALLATION INSTRUCTIONS INSTALLATION: 1. Cut proper opening in ceiling. Round: 140mm Ø, Square: 140mm x 140mm 140mm Ø 140mm x 140mm 2. Connect driver to power source leads. After connections are made,

More information

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES Kurt Versen Company Point Source Lighting 10 Charles Street Westwood, New Jersey Models with Square or Rectangular Apertures 1 PLEASE READ THIS ENTIRE INSTRUCTION SHEET BEFORE INSTALLATION. 2 DISCONNECT

More information

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P Inde-Pendants Family 32L Ring Plaster Trim, Grid and Drywall Ceiling Types Installation instructions for 32L-Rxx-P Document No. Supplied by Litecontrol 32L Inde-Pendants: Ring (Plaster Trim, Grid and Drywall

More information

Installing Fixture Using Remote Power Supply

Installing Fixture Using Remote Power Supply 2017 Edge Lighting. All Rights Reserved. 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1195 Fax: 773-935-5613 www.edgelighting.com info@edgelighting.com 904-BV2-2K4K-_03 BV2-1RE-_-2K4K-_ Installation

More information

Installation Instructions For Reveal

Installation Instructions For Reveal 2017 Pure Lighting. All Rights Reserved. Installation Instructions For Reveal IS# 902-RV-24VDC-07 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1196 Fax: 773-883-6128 www.purelighting.com info@purelighting.com

More information

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES Kurt Versen Company Point Source Lighting Models with Round Apertures 10 Charles Street Westwood, New Jersey 1 PLEASE READ THIS ENTIRE INSTRUCTION SHEET BEFORE INSTALLATION. 2 DISCONNECT ELECTRICAL POWER

More information

LED RECESSED ADJUSTABLE 3-1/4 APERTURE Non-IC Rated, 1000 LUMEN TC49L, TC949L

LED RECESSED ADJUSTABLE 3-1/4 APERTURE Non-IC Rated, 1000 LUMEN TC49L, TC949L PRODUCT DESCRIPTION Recessed adjustable 0W LED luminaire produces up to 000 fixture lumens (depending on trim) and approximates the performance of a 75W MR6 lamp. Fixture has 50 visual cutoff and features

More information

Installation Instructions for DIY or Completed 45 Degree Light Channel

Installation Instructions for DIY or Completed 45 Degree Light Channel 201 Edge Lighting. All Rights Reserved. Installation Instructions for DIY or Completed Degree Light Channel IMPORTANT INFORMATION - This instruction shows a typical installation. 11 W. Fullerton Ave Chicago,

More information

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Inde-Pendants Family 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types Installation instructions for 32L-CRxx-S-D Document No. Supplied by Litecontrol 32L Inde-Pendants:

More information

INDIVIDUAL MOUNTING: T-Bar

INDIVIDUAL MOUNTING: T-Bar X1 (T-BAR) INSTALLATION INSTRUCTIONS GENERAL NOTES NOTE : Additional support to structural member may be required. Check with local building codes for requirement. 1. Place troffer clamp approx. 6 from

More information

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No Inde-Pendants Family 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types Installation instructions for 32L-C-S-D Document No. Supplied by Litecontrol 32L Inde-Pendants: Cylinder (Surface

More information

Installation Instructions for Cirrus Suspension Downlight with Power - End Feed. Section One: 4" Flush Canopy Version

Installation Instructions for Cirrus Suspension Downlight with Power - End Feed. Section One: 4 Flush Canopy Version Doc # 0-CSP-E_0 W. Fullerton Chicago, IL 606 Ph:.0. Fax:..6 www.pureedgelighting.com info@pureedgelighting.com 06 PureEdge Lighting. All Rights Reserved. Installation Instructions for Cirrus Suspension

More information

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS WARNING: This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Make sure all

More information

5 ACCESS PANEL INSTALLATION SPACER *SLIDE TO LOCATION OF FASTENER DURING INSTALLATION OF EACH FASTENER

5 ACCESS PANEL INSTALLATION SPACER *SLIDE TO LOCATION OF FASTENER DURING INSTALLATION OF EACH FASTENER 1/2 K.O. (3/8 K.O. on 165 with factory supplied 3/8 flex conduit fitting) TR - Trim Flange Side Blocking Install Method Secure fixture to structure following instructions below: 1. Remove lens and internal

More information

Installation Instructions for DIY or Completed Light Channel.6 Millwork

Installation Instructions for DIY or Completed Light Channel.6 Millwork 2017 Edge Lighting. All Rights Reserved. 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 77-770-1195 Fax: 77-95-561 www.edgelighting.com info@edgelighting.com LCMW.6- - - 904-LCMW.6_02 Installation Instructions

More information

with Lamp Install the Housing with Adjustable Bars Installation Instructions for LED E3_-L_DN 1.1 ½ to ¾ ¾ or thicker

with Lamp Install the Housing with Adjustable Bars Installation Instructions for LED E3_-L_DN 1.1 ½ to ¾ ¾ or thicker Installation Instructions for 90ELED-D Round or Square Type IC, Non-IC Down Light Housing with Lamp LED E_-L_DN. LED - ROUND/ SQUARE GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations.

More information

Installation Instructions For Reveal Light Channel

Installation Instructions For Reveal Light Channel 2016 Pure ighting. All Rights Reserved. Installation Instructions For Reveal ight Channel IS# 902-RV-24VDC-06 1718 W. Fullerton Ave Chicago, I 60614 Tel: 773-770-1195 Fax: 773-935-5613 www.purelighting.com

More information

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

Line volt rail & fixtures. Low volt quick connect fixtures with transformers INSTRUCTIONS: Line Volt Flexrail2 Safety Instructions: A qualified electrician must install system only. System is intended for installation in accordance with National Electric Code, local and Federal

More information

Installation Instructions for Zip Suspension Downlight with Remote Power and 4" Square or Round Canopy

Installation Instructions for Zip Suspension Downlight with Remote Power and 4 Square or Round Canopy Doc # 90-ZS-SQ_0 W. Fullerton Chicago, IL 0 Ph:.0.9 Fax:.9. www.pureedgelighting.com info@pureedgelighting.com 0 PureEdge Lighting. All Rights Reserved. Installation Instructions for Zip Suspension Downlight

More information

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS TruGroove Drywall A3 MOUNTING Ceiling INSTALLATION System Overview These instructions review how to install trimless drywall versions of TruGroove

More information

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200/1500/2000 LUMEN SQUARE APERTURE NEW CONSTRUCTION IC/TC420LSQ, IC415LSQ, IC412LSQ, IC408LSQ

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200/1500/2000 LUMEN SQUARE APERTURE NEW CONSTRUCTION IC/TC420LSQ, IC415LSQ, IC412LSQ, IC408LSQ PRODUCT DESCRIPTION Recessed adjustable LED luminaire produces up to 000 delivered lumens. Fixture has 50 visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum

More information

INSTALLATION INSTRUCTIONS Oculux 3.5 Architectural Remodel

INSTALLATION INSTRUCTIONS Oculux 3.5 Architectural Remodel SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. - Read all instructions before installing. - System is intended for installation by a qualified electrician in

More information

BLACK BODY DIMMING & TUNABLE WHITE 1000 LUMEN ADJUSTABLE, DOWNLIGHT AND WALL WASH LED ROUND APERTURE IC410T, TC410T P1.16.0

BLACK BODY DIMMING & TUNABLE WHITE 1000 LUMEN ADJUSTABLE, DOWNLIGHT AND WALL WASH LED ROUND APERTURE IC410T, TC410T P1.16.0 PRODUCT DESCRIPTION Recessed LED luminaire compatible with adjustable, downlight and wall wash trims, features both Black Body Dimming and Tunable White technology in a single fixture and delivers up to

More information

Prepare the Fixture. Sage 37 Bath. Back Plate Installation (Horizontal) Installation Instructions for 700BCSAGW37_

Prepare the Fixture. Sage 37 Bath. Back Plate Installation (Horizontal) Installation Instructions for 700BCSAGW37_ Installation Instructions for Sage Bath 00BCSAGW_ 90BCSAGEL.0 BATH COLLECTION GENERAL PRODUCT I NFORMATION: This fixture is intended to be installed utilizing NEC compliant junction boxes. This product

More information

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200 LUMEN ROUND APERTURE REMODEL IC408LR, TC412LR

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200 LUMEN ROUND APERTURE REMODEL IC408LR, TC412LR PRODUCT DESCRIPTION Recessed adjustable LED remodel luminaire produces up to 00 delivered lumens. Fixture has 50 visual cutoff. Low profile housing is available in both IC and Non-IC rated configurations.

More information

TASK: Replace Control Mechanism/Drive End for G71 Supervue/Everglide Vertical headrail

TASK: Replace Control Mechanism/Drive End for G71 Supervue/Everglide Vertical headrail 1. Locate the clear plastic louver stems where louvers are attached. 2. Rotate louvers open. Slide a hard plastic card between the louver and the long side of the louver stem. Push the card and louver

More information

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls Tools Required: Phillips Screwdriver (#2) Adjustable Wrench Level Tape Measure Utility Knife Electric Drill Drill Bits for Anchors Ladder (4 foot) Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

More information

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42 - 60 Plasma Screens Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens Models: PLAV 70-UNL, PLAV 70-UNL-S PLAV 70-UNLP, PLAV 70-UNLP-S R This product is UL Listed. It must be

More information

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT EXPLODED VIEW AND PART CALL OUT CUTOUT DIMENSIONS ON PAGE 2 CEILING BRACING (BY OTHERS) SHEET ROCK METALUX DF SERIES FRAME KIT S282 (2'X2') FIXTURE SHOWN FIXTURE SIZE FRAME KIT PART # 2' X 2' DF-22W-U

More information

Installation Instruction

Installation Instruction Tools Needed for Assembly Stud finder (for wood stud wall) Pencil Mark Electric drill Wood Stud Wall Installation Step 1. Locate the Wood Studs Installation Instruction Drill bit (for wood stud wall) Masonry

More information

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System IMPORTANT SAFETY INSTRUCTIONS: Read all instructions before installation. Save these instructions for later use.

More information

PMT-L31 (for Low Ceilings) PMT-H35 (for High Ceilings)

PMT-L31 (for Low Ceilings) PMT-H35 (for High Ceilings) English Ceiling Mount Bracket PMT-L31 (for Low Ceilings) PMT-H35 (for High Ceilings) Installation Manual Be sure to read this manual thoroughly before using this bracket. After you have read this manual,

More information

PORTA~TRACE. GAGNE, INC. 41 Commercial Dr. Johnson City, New York Phone: Fax: ASSEMBLY INSTRUCTIONS

PORTA~TRACE. GAGNE, INC. 41 Commercial Dr. Johnson City, New York Phone: Fax: ASSEMBLY INSTRUCTIONS PORTA~TRACE GAGNE, INC. 41 Commercial Dr. Johnson City, New York 13790 Phone: 1-607-729-3366 Fax: 1-607-729-7644 ASSEMBLY INSTRUCTIONS PORTA~TRACE MODEL 2436T LIGHT TABLE PORTA~TRACE MODEL 3648T LIGHT

More information

C 0.05" ALLEN WRENCH. Installation Instructions for Cirrus Channel Suspension T1 with 4" Square or Round Canopy. Section One: Adjusting Cable Position

C 0.05 ALLEN WRENCH. Installation Instructions for Cirrus Channel Suspension T1 with 4 Square or Round Canopy. Section One: Adjusting Cable Position Doc # 90-CST-SQ_0 W. Fullerton Chicago, IL 0 Ph:.0.9 Fax:.9. www.pureedgelighting.com info@pureedgelighting.com 0 PureEdge Lighting. All Rights Reserved. Installation Instructions for Cirrus Channel Suspension

More information

General Installation Instructions LED

General Installation Instructions LED General Installation Instructions LED To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions and other hazards, please read all warnings

More information

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver. - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS TruGroove Drywall A3 MOUNTING Ceiling INSTALLATION System Overview These instructions review how to install drywall trim versions of TruGroove recessed

More information

REGOLO GENERAL WARNING

REGOLO GENERAL WARNING REGOLO GENERAL WARNING WARNING: DO NOT ASSEMBLE CONTINUOUS RUN ON THE GROUND AND LIFT INTO PLACE. JOINTS WILL DISTORT AND NOT CREATE A TIGHT FIT. JOINING HARDWARE WILL HAVE TO BE PURCHASED AND REPLACED.

More information

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. LumeLEX 2026 SERIES INSTALLATION INSTRUCTIONS Important THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. Warning This product must be installed in accordance with National Electrical

More information

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange - Trim System Overview These instructions review how to install TruGroove Perimeter fixtures. Modules can be installed as individual standalone units, or they can be joined together to create continuous

More information

LOW PROFILE 3-1/4 LED RECESSED ADJUSTABLE, DOWNLIGHT AND WALL WASH 800/1200/1500/2000 LUMEN ROUND APERTURE TC420LP, IC415LP, IC412LP, IC408LP

LOW PROFILE 3-1/4 LED RECESSED ADJUSTABLE, DOWNLIGHT AND WALL WASH 800/1200/1500/2000 LUMEN ROUND APERTURE TC420LP, IC415LP, IC412LP, IC408LP PRODUCT DESCRIPTION Low Profile recessed LED luminaire compatible with downlight, adjustable and wall wash trims, is less than 4 tall and produces up to 000 delivered lumens. Fixture has 45 visual cutoff

More information

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER INSTALLATION INSTRUCTIONS RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER NOTE: The following instructions provide general guidelines for product installation. For additional information

More information

HP 2 SERIES Integral Driver - Solid State LED

HP 2 SERIES Integral Driver - Solid State LED HP 2 SERIES Installation Instructions Warning High Voltage Hot Surface NEEDED FOR INSTALLATION: By Others 1/8 & 5/32 Allen Wrench Waterproof Wire Connectors Level Phillips Screwdriver IMPORTANT - WEAR

More information

Installation Instructions for TruLine 1A Center Feed Power Channel Connector

Installation Instructions for TruLine 1A Center Feed Power Channel Connector IMPORTANT INFORMATION - This instruction must be used concurrently with other TruLine A BIY installation instructions. - This product is wall or ceiling mount. - This instruction shows a typical installation.

More information

INSTALLATION INSTRUCTION Solorail - Low Voltage Starter Kit

INSTALLATION INSTRUCTION Solorail - Low Voltage Starter Kit IMPORTANT SAFETY INSTRUCTIONS: Read all instructions. Turn off power at main switch before installing or modifying the system. Do not install the system: - Within six inches of any curtain or combustible

More information

INSTALLATION INSTRUCTION Indirect Recessed Channel

INSTALLATION INSTRUCTION Indirect Recessed Channel SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. Always turn off power at fuse box prior to installation to prevent electrical

More information

TIP FOR GETTING STARTED

TIP FOR GETTING STARTED Tip for getting started TIP FOR GETTING STARTED Be careful not to drill into any electrical wires, ductwork, plumbing or other damagable components. If you have any questions on the locations of these

More information

3% VOLTAGE DROP. Installation Instructions for 400 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS!

3% VOLTAGE DROP. Installation Instructions for 400 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS! Installation Instructions for 400 Watt 24 Volt DC RGB DMX LED Power Supply Doc # 904-PSB-400W-24VDC_06 1718 W. Fullerton Chicago, IL 60614 Ph: 773.770.1195 Fax: 773.935.5613 www.pureedgelighting.com info@pureedgelighting.com

More information

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE T F W 604.549.979 604.549.9555 fluxwerx.com INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE fixture housing endcap kit optic kit join kit notch 2 cross section notch 4 cross section 4 4" 4-11/2" 4 /8 (111)

More information

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE: INSTALLATION INSTRUCTIONS RAIL 4 RM4DOD Recessed NOTE: The following instructions provide general guidelines for product installation. For additional information consult the applicable electrical codes

More information

Installation Instructions. Oakmont Folding Doors

Installation Instructions. Oakmont Folding Doors Before You Start For quick and easy installation of your Oakmont folding door, read these instructions thoroughly. A few minutes of prior planning will make the job easier and ensure years of trouble-free

More information

Figure A. Figure B. Figure C. Figure D

Figure A. Figure B. Figure C. Figure D Xsite 1 Power/Data Tile and Components Tools Required Tape Measure Cordless Drill/Driver #2 Phillips Screw driver bit Rubber Mallet Flat Blade Screwdriver Figure A Hardware Required Provided as shown Installation

More information

SLOT INSTALLATION GUIDE Indoor IP20

SLOT INSTALLATION GUIDE Indoor IP20 Please read entire guide prior to starting installation. Sections: Pre-Installation Single Run Fed From Both Ends NOTES 1. IP40 and lower tape must be installed indoors only. Installing outdoors will void

More information

INSTALLATION INSTRUCTION OCULUX 3 LED - New Construction

INSTALLATION INSTRUCTION OCULUX 3 LED - New Construction R3BNICA-10 SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician

More information

B235 Mobius Sconce Page 1 of 6

B235 Mobius Sconce Page 1 of 6 Mobius Sconce 28-9450 Page 1 of 6 CAUTION: FAILURE TO INSTALL THIS PRODUCT PROPERLY MAY RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE. We recommend installation by a qualified individual trained in the

More information

Assembly and Installation Guide

Assembly and Installation Guide The Easy Hang Closet Solution SM Install Your elfa In An Instant. Enjoy The Benefits For A Lifetime. Basic Tools For elfa Assembly and Installation Level Hand or Power Drill Drill Bits 1/8", 3/8", 5/16"

More information

GLASS GLOBE MOBILE LINEAR CHANDELIER

GLASS GLOBE MOBILE LINEAR CHANDELIER PARTS ENCLOSED: (B) Top ceiling plate [1] (C) Bottom ceiling plate [1] (D) Glass globes [7] (E) Screws [6] (F) Nuts [5] (G) Extension rods [15] (H) Transformer [1] (I) Threaded inserts [5] (J) 1.6W LED

More information

Ø1.80 (46) Aperture Lens Location. Ball Catch Retainers

Ø1.80 (46) Aperture Lens Location. Ball Catch Retainers VF150 Series - 9601 Trim RECESSED ROUND BEVELED ACCENT 1-LIGHT TRIMLESS LED PROJECT TYPE CATALOG NUMBER Measurements in ( ) are metric equivalents. ROUND BEVELED TRIMLESS ACCENT - The VF150 Series is a

More information

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42 - 60 Plasma Screens Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens Models: PLAV 70-UNL, PLAV 70-UNL-S PLAV 70-UNLP, PLAV 70-UNLP-S R This product is UL Listed. It must be

More information

SURFACE CLIP MOUNT. 1 Insert lens into channel, measure, and cut to length. Remove lens cover from channel. surface. Attach lens cover and end caps

SURFACE CLIP MOUNT. 1 Insert lens into channel, measure, and cut to length. Remove lens cover from channel. surface. Attach lens cover and end caps SURFACE CLIP MOUNT 1 Insert lens into channel, measure, and cut to length Remove lens cover from channel Screw mounting clips into mounting Snap channel into mounting clips Attach lens cover and end caps

More information

General Installation Instructions

General Installation Instructions General Installation Instructions WARNING To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions, falling parts and other hazards: Service of the equipment must

More information

INS T A L L A TIO N INS T R U C TIO N S. Ceiling Mount Track System

INS T A L L A TIO N INS T R U C TIO N S. Ceiling Mount Track System Ceiling Mount Track System 10.26.2016 Specifications Ceiling Post: Unassembled 2-7/8 Assembled 1-11/16 7/8 7-9/16 5-7/8 3/8 2 Tubes 1/2 2-3/8 5 Parts and Tools Tools Needed Tape Measure Pencil Drill with

More information

INSTALLATION MANUAL PBL-UMP

INSTALLATION MANUAL PBL-UMP INSTALLATION MANUAL PBL-UMP Table of Contents Warning Statements... 4 Parts List... 5 Installation Tools... 5 Features... 7 Projector Preparation... 8 Bracket Installation... 10 Leveling the Mounting Bracket...

More information

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200 LUMEN ROUND APERTURE REMODEL IC408LR, TC412LR

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200 LUMEN ROUND APERTURE REMODEL IC408LR, TC412LR PRODUCT DESCRIPTION Recessed adjustable LED remodel luminaire produces up to 00 delivered lumens. Fixture has 45 visual cutoff. Low profile housing is available in both IC and Non-IC rated configurations.

More information

Inigo Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5

Inigo Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5 P31321 1 of 5 Thank You For Choosing Kallista We appreciate your commitment to Kallista quality products. Please take a moment to review this manual before you install your Kallista product. If you encounter

More information

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR RECESSED EDGE-LIT LED EXIT SIGN Standard and New York Approved Models (Emergency, non-emergency and X2 Dual Circuit operation) READ AND FOLLOW ALL SAFETY INSTRUCTIONS IMPORTANT SAFEGUARDS: When using

More information

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series Specifications: Designed for installation on single wood studs or drywall (1/2" minimum thickness); either option

More information

INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS INSTALLATION AND CARE INSTRUCTIONS Vertical Applications Honeycomb Shades CONTENTS Introduction...2 Before You Begin...3 Vertical Application Parts Overview...4 Materials Required...5 Tools Required...6

More information

END FEED INSTALLATION

END FEED INSTALLATION STARLINE PLUG-IN RACEWAY END FEED INSTALLATION The Universal End Feed (product numbers beginning with URPF, URDF, or MRPF, MRDF) provides the installer a provision to connect supply power to the Plug-In

More information

MyStudio VS53 Versa Sweep Setup Instructions

MyStudio VS53 Versa Sweep Setup Instructions MyStudio VS53 Versa Sweep Setup Instructions MISSION STATEMENT Pro Cyc, Inc. is the world leader in design and sales of modular infinity backgrounds. Our studio systems are recommended by every major company

More information

SUPERPLANE 2.5 INSTALLATION INSTRUCTIONS WALL/SURFACE BACK MOUNT. A nd Avenue, Unit 1 Oakland,

SUPERPLANE 2.5 INSTALLATION INSTRUCTIONS WALL/SURFACE BACK MOUNT. A nd Avenue, Unit 1 Oakland, INSTALLATION INSTRUCTIONS SUPERPLANE 2.5 WALL/SURFACE BACK MOUNT A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com SP2.5 - Safety & Warnings! 1. Read all instructions.

More information

J-BOX. 3-O or 4-0 MUD RING J-BOX BRACKET BAR CABLE GRIPPER/ CANOPY MOUNTING STUD 8-32 BRACKET BAR SCREWS CANOPY STRAIN RELIEF POWER CORD CANOPY

J-BOX. 3-O or 4-0 MUD RING J-BOX BRACKET BAR CABLE GRIPPER/ CANOPY MOUNTING STUD 8-32 BRACKET BAR SCREWS CANOPY STRAIN RELIEF POWER CORD CANOPY KELSEY - CSS Cable Suspended Rotational and Static CSS - Cable Suspended 3-O or 4-0 MUD RING BRACKET BAR 1/4-20 STUD 8-32 BRACKET BAR SCREWS STRAIN RELIEF POWER CORD MOUNTING GRIPPER AIRCRAFT CABLE CABLE

More information

flat panel solutions Specifications Box contents Warnings CAUTION: Tilt Wall Mount for LCD, Plasma, and LED Displays Instruction Manual

flat panel solutions Specifications Box contents Warnings CAUTION: Tilt Wall Mount for LCD, Plasma, and LED Displays Instruction Manual flat panel solutions Tilt Wall Mount for LCD, Plasma, and LED Displays Instruction Manual MST65BKR Fits TVs 37-65 Maximum Load Capacity 165 lb (75kg) Specifications Display Size: 37 to 65 Maximum Load:

More information

SAE of 7 "R" (REGRESSED) POSITION "S" (SHIELDING AT TOP) POSITION. Tools Required

SAE of 7 R (REGRESSED) POSITION S (SHIELDING AT TOP) POSITION. Tools Required SAE 0 5/6'' Exposed TBar Ceiling FINISHED EDGE WITH JANGLE 90 IC CORNER KIT 5 7/6" 38mm 9/6'' Screw Slot TBar Ceiling "R" (REGRESSED) POSITION 6" CEILING OPENING "S" (SHIELDING AT TOP) POSITION SUPPORT

More information

mila-wall (Series100) General Operating Instructions page 1 of 15

mila-wall (Series100) General Operating Instructions page 1 of 15 mila-wall (Series100) General Operating Instructions page 1 of 15 Step #1: Before setting up walls, lower adjustable leveling feet on each panel approximately 1". This will allow access to the threaded

More information

8.50 (216) Ball Catch Retainers 3.00 (76) Aperture Lens Location .74 (19)

8.50 (216) Ball Catch Retainers 3.00 (76) Aperture Lens Location .74 (19) VF150 Series - 8704 Trim RECESSED RECTANGULAR BEVELED ACCENT 2-LIGHT TRIMMED LED PROJECT TYPE CATALOG NUMBER Measurements in ( ) are metric equivalents. RECTANGULAR BEVELED TRIMMED ACCENT - The VF150 Series

More information

INSTALLATION GUIDE. Table saw or circular saw with fine-tooth blade, caulking gun, rule/tape, drill, file, hammer, plumb line/level, ridge/support.

INSTALLATION GUIDE. Table saw or circular saw with fine-tooth blade, caulking gun, rule/tape, drill, file, hammer, plumb line/level, ridge/support. Code: IG- Page : 1 of 6 Installation recommendations 1-Pre-Installation The recommendations provided in the bulletin represent our best judgment based on our experience with normal applications. Any deviation

More information

INSTALLATION MANUAL PBC-UMS

INSTALLATION MANUAL PBC-UMS INSTALLATION MANUAL. PBC-UMS Premier Mounts 3130 E. Miraloma Avenue Anaheim, CA 92806 Phone: (800) 368-9700 Fax: (800) 832-4888 mounts@mounts.com www.mounts.com Rev. 01 PBL-110 Projector Mount Page 2 Installation

More information

PMT-L11 (for Low Ceilings) PMT-H15 (for High Ceilings)

PMT-L11 (for Low Ceilings) PMT-H15 (for High Ceilings) English Français Deutsch Svenska Italiano Español Nederlands Digital Cinema Projector Ceiling Bracket PMT-L11 (for Low Ceilings) PMT-H15 (for High Ceilings) Installation Manual Be sure to read this manual

More information

HP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview

HP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview Overview Step 4 Mounting to Structure Page 6 Step 1 Mounting Locations & Rough-Ins Pages 2-3 Step 2 Identification & Preparation Page 4 Step 6 Securing Corner Joints Page 8 Step 3 Opening Luminaires Page

More information

Connecting the Channel A

Connecting the Channel A 20 Edge Lighting. All Rights Reserved. Installation Instructions for Cirrus Channel Suspension T, Tubular Lens w/2sq or 2RD Canopy IMPORTANT INFORMATION - This product is suitable for indoor locations.

More information

INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS INSTALLATION AND CARE INSTRUCTIONS Vertical Applications Honeycomb Shades 52 C8-10-3401 Rev 2/14 CONTENTS Introduction...2 Before You Begin...3 Vertical Application Parts Overview...4 Materials Required...5

More information

Installation, Operation and Care Instructions. Retractable Cord Operating System

Installation, Operation and Care Instructions. Retractable Cord Operating System Installation, Operation and Care Instructions Retractable Cord Operating System CONTENTS Getting Started: Product View... 1 Tools and Fasteners Needed... 2 Installation: Installation Overview... 3 Mount

More information

FABA. Installation Instructions. Conductor Bar System. Publication #FABA-03 3/1/04 Part Number: Copyright 2004 Electromotive Systems

FABA. Installation Instructions. Conductor Bar System. Publication #FABA-03 3/1/04 Part Number: Copyright 2004 Electromotive Systems FABA Conductor Bar System Installation Instructions Publication #FABA-03 3/1/04 Part Number: 005-1062 Copyright 2004 Electromotive Systems 1S 100 Z Installation Instructions Contents: Basic Diagram - -

More information

Custom Pendant- Hardwire Assembly and Installation Instructions

Custom Pendant- Hardwire Assembly and Installation Instructions Custom Pendant- Hardwire Assembly and Installation Instructions CAUTION: BEFORE INSTALLING FIXTURE, MAKE SURE THE POWER TO THE CIRCUIT IS TURNED OFF AT THE MAIN FUSE BOX / CIRCUIT BREAKER UTILITY BOX.

More information

ZIP CLOUD SUSPENDED INSTALLATION MANUAL

ZIP CLOUD SUSPENDED INSTALLATION MANUAL ZIP CLOUD SUSPENDED INSTALLATION MANUAL www.delviro.com info@delviro.com 1.877.502.3434 SAFETY NOTE: Follow the Electrical Codes of the Country where this fixture will be installed. For Canada follow the

More information

Installation Instructions

Installation Instructions Installation Instructions Follow these simple instructions to install your OneDayCab! IMPORTANT: Unpack and check shipment for damage. Verify color, size and parts before demolition. Installation of interiors