SkillsUSA 2013 Contest Projects Electrical Construction Wiring
|
|
- Gerald Davis
- 6 years ago
- Views:
Transcription
1 SkillsUSA 2013 Contest Projects Electrical Construction Wiring Click the Print this Section button above to automatically print the specifications for this contest. Make sure your printer is turned on before pressing the button.
2 Download additional contest files.
3 2013 SkillsUSA NLSC Electrical Construction Wiring Contestant Number: LETTER DEVICE TYPE BOX DESCRIPTION HEIGHT LOCATION BOX MOUNTING CIRCUIT CABLE LIST A Keyless Receptacle 4" Round Plastic with Bar Hanger 60 Inches Top Stud Wall A 2 screws 1 B Keyless Receptacle 4" Round Plastic Nail Up 58 Inches Bottom Stud Wall B Nail Up 2 RX - Nonmetallic Sheeted Cable C Keyless Receptacle 4" Round Plastic Nail Up 61 Inches Bottom Stud Wall C Nail Up 3 UF-Underground Feeder and Branch Circuit Cable D Three Way Switch Plastic 1-gang N.W. Box 36 Inches Top Stud Wall B Nail Up 2 MC - Metal Clad Cable E Single Pole Switch Plastic 2-gang N.W. Box 42 Inches Bottom Stud Wall A Nail Up 1 F 4 Way Switch Plastic 2-gang N.W. Box 42 Inches Bottom Stud Wall A Nail Up 2 G Tamper Proof GFCI Receptacle Plastic 1-gang N.W. Box 42 Inches Bottom Stud Wall A Nail Up 1 H Junction Box 4 11/16"x 4 11/16 Square Box See Notes See Notes Screws NA I Single Pole Switch Plastic 1-gang N.W. Box 44 Inches Top Stud Wall B Nail Up 3 J Keyless Receptacle 4" Metal Octagon Box 69 Inches Bottom Plywood 2 Screws 4 K Duplex Receptacle Metal Cut-in Box 12 inches Bottom Stud Wall A Madison Straps(F-clips) 1 L Tamper Proof Duplex Receptacle Plastic 1-gang N.W. Box 14 Inches Bottom Stud Wall B Nail Up 1 M 3 Way Switch 4"X4" Square Box w/1gang Device Ring 36 Inches Bottom Stud Wall C 2 Screws 2 N Flush Mount Telephone Jack Handy Box 6 Inches Bottom Plywood 2 Screws NA P Single Pole Switch 4"X4" Square Box w/1gang Device Ring 31 Inches Bottom Plywood 2 Screws 4 Q Flush Mount Telephone Jack Single Gang Low-Voltage Cut-in Ring 6 Inches Top Stud Wall A N/A NA R Main Panel Main Panel 51 Inches Bottom Plywood 4 Screws NA S GFCI Receptacle 4"X4" Square Box w/1gang Device Ring 10 Inches Bottom Plywood 2 Screws 4 T Disconect Disconect 51 inches Bottom Plywood 3 Screws 2,3 U AC/DC Smoke Detector 4" Metal Octagon Box w/mounting Bracket 48 Inches Top Stud Wall C 2 screws 3 1. Use Outside Back K.O.'s 14. Devices "I" to control Device "C" 26. Device "S" To be only GFCI Protected Device on circuit 2. Center Box "A" Between Studs 15. Devices "D", "M" and "F" to control Device "B" 27. Box "K", "Q" to be center between studs, Heights per Notes above 3. All Saddles to be 3-point Saddles 16. Write your Contestant Number on all paper work on the line provided 28. Circuits "2 and 3" shall share a grounded conductor 4. Box Height "H" to be determined by pipe feed from box "S" 17. Device "G" to protect Devices "A","E","L", and "K" 29. Use 1/2" K.O. in Box "M" nearest to the stud 5. Box "H" To be mounted on face of stud between wall "B" and "C" 18. Device "P" to control Device "J" 30. Smoke Detector To be Hot all the time( Wiring Harness Only) 6. Box "K" to be mounted Long Side parallel to the ground as shown. 19. Telephone Jacks to be interconnected with Blue Pairs as Primary Line 30. Wire between Box "E" and "K" to be 14/3 7. "K" to be Right Half Switched and Left Half Hot controlled by Device "E" 20. Panel is a Main Panel 31. Do NOT Drill holes in studs with out asking first. 8. All wire to be R/X unless otherwise noted on the Prints 21. Do Not stab ANY Devices 32. Use Orange Pair as the secondary line on the phone jack 9. All Ciruits in the same conduit shall share a common grounding conductor 22. Do Not Mount ANY devices to boxes 33. Use Romex staples for Romex only 10. Fittings are not of grounding type 23. All heights to be measured off of finished floor. 34 Keep your area clean at all times 11. Use box offsets for all pipe terminations where possiable 24. Any measurements on plywood to be off edge of plywood. 35. Device "L" to be hot all the time 12. Ground all metal boxes 25. Use Proper wire nuts for all locations 36. Draw a Smiley Face Next to Contestant Number 13. Use Low voltage staples for telephone wire 26. Device "E" to control Device "A" 37. Have a Wonderful Day and GOOD LUCK
4 2013 SkillsUSA NLSC Electrical Construction Wiring LETTER DEVICE TYPE BOX DESCRIPTION HEIGHT LOCATION BOX MOUNTING CIRCUIT A Keyless Receptacle 4" Round Plastic with Bar Hanger 60 Inches Top Stud Wall A 2 screws 1 B Keyless Receptacle 4" Round Plastic Nail Up 58 Inches Bottom Stud Wall B Nail Up 2 C Keyless Receptacle 4" Round Plastic Nail Up 61 Inches Bottom Stud Wall C Nail Up 3 D Three Way Switch Plastic 1-gang N.W. Box 36 Inches Top Stud Wall B Nail Up 2 E Single Pole Switch Plastic 2-gang N.W. Box 42 Inches Bottom Stud Wall A Nail Up 1 F 4 Way Switch Plastic 2-gang N.W. Box 42 Inches Bottom Stud Wall A Nail Up 2 G Tamper Proof GFCI Receptacle Plastic 1-gang N.W. Box 42 Inches Bottom Stud Wall A Nail Up 1 H Junction Box 4 11/16"x 4 11/16 Square Box See Notes See Notes Screws NA I Single Pole Switch Plastic 1-gang N.W. Box 44 Inches Top Stud Wall B Nail Up 3 J Keyless Receptacle 4" Metal Octagon Box 69 Inches Bottom Plywood 2 Screws 4 K Duplex Receptacle Metal Cut-in Box 12 inches Bottom Stud Wall A Madison Straps(F-clips) 1 L Tamper Proof Duplex Receptacle Plastic 1-gang N.W. Box 14 Inches Bottom Stud Wall B Nail Up 1 M 3 Way Switch 4"X4" Square Box w/1gang Device Ring 36 Inches Bottom Stud Wall C 2 Screws 2 N Flush Mount Telephone Jack Handy Box 6 Inches Bottom Plywood 2 Screws NA P Single Pole Switch 4"X4" Square Box w/1gang Device Ring 31 Inches Bottom Plywood 2 Screws 4 Q Flush Mount Telephone Jack Single Gang Low-Voltage Cut-in Ring 6 Inches Top Stud Wall A N/A NA R Main Panel Main Panel 51 Inches Bottom Plywood 4 Screws NA S GFCI Receptacle 4"X4" Square Box w/1gang Device Ring 10 Inches Bottom Plywood 2 Screws 4 T Disconect Disconect 51 inches Bottom Plywood 3 Screws 2,3 U AC/DC Smoke Detector 4" Metal Octagon Box w/mounting Bracket 48 Inches Top Stud Wall C 2 screws 3 1. Use Outside Back K.O.'s CABLE LIST 2. Center Box "A" Between Studs 3. All Saddles to be 3-point Saddles 4. Box Height "H" to be determined by pipe feed from box "S" RX - Nonmetallic Sheeted Cable 5. Box "H" To be mounted on face of stud between wall "B" and "C" UF-Underground Feeder and Branch Circuit Cable 6. Box "K" to be mounted Long Side parallel to the ground as shown. MC - Metal Clad Cable 7. "K" to be Right Half Switched and Left Half Hot controlled by Device "E" 8. All wire to be R/X unless otherwise noted on the Prints 9. All Ciruits in the same conduit shall share a common grounding conductor 10. Fittings are not of grounding type 11. Use box offsets for all pipe terminations where possiable 12. Ground all metal boxes 13. Use Low voltage staples for telephone wire 14. Devices "I" to control Device "C" 15. Devices "D", "M" and "F" to control Device "B" 16. Write your Contestant Number on all paper work on the line provided 17. Device "G" to protect Devices "A","E","L", and "K" 18. Device "P" to control Device "J" 19. Telephone Jacks to be interconnected with Blue Pairs as Primary Line 20. Panel is a Main Panel 21. Do Not stab ANY Devices 22. Do Not Mount ANY devices to boxes 23. All heights to be measured off of finished floor. 24. Any measurements on plywood to be off edge of plywood. 25. Use Proper wire nuts for all locations 26. Device "E" to control Device "A" 26. Device "S" To be only GFCI Protected Device on circuit 27. Box "K", "Q" to be center between studs, Heights per Notes above 28. Circuits "2 and 3" shall share a grounded conductor 29. Use 1/2" K.O. in Box "M" nearest to the stud 30. Smoke Detector To be Hot all the time( Wiring Harness Only) 30. Wire between Box "E" and "K" to be 14/3 31. Do NOT Drill holes in studs with out asking first. 32. Use Orange Pair as the secondary line on the phone jack 33. Use Romex staples for Romex only 34 Keep your area clean at all times 35. Device "L" to be hot all the time 36. Draw a Smiley Face Next to Contestant Number 37. Have a Wonderful Day and GOOD LUCK
5
6
7
8
PROVINCIAL CONTEST DESCRIPTION & INSTRUCTIONS ELECTRICAL WIRING TRADE 18. Post Secondary 2016
PROVINCIAL CONTEST DESCRIPTION & INSTRUCTIONS ELECTRICAL WIRING TRADE 18 Post Secondary 2016 GENERAL INSTRUCTIONS... 3 SAFETY... 3 MATERIAL... 3 DIMENSIONS... 3 DISCUSSION... 3 STUD WALL WIRING... 3 SURFACE
More informationRound/Octagon Boxes and Accessories
Round/Octagon Boxes and Accessories 4" Round Boxes DEPTH BOTTOM CAT. NO. (IN.) CAPACITY DESCRIPTION CONDUIT CTN. 56111 1 2 6.0 Steel outlet box 4 1 2 50 56111-CFB* 1 2 6.0 Ceiling fan box with plastic
More informationSpring Steel Fasteners
Cable Support Supports up to 4 runs of MC and AC cable and up to 6 runs of nonmetallic sheathed cable Installs with nails or staple or sheet metal screws Complies with CEC article 12-516 for all wood and
More informationWiring Devices. Description. Lesson Outcomes. Assumptions. Electrician
Description Once a house has been roughed in and has passed an electrical inspection, it s time for the electricians to do the final job of wiring and installing devices. Most trades have a finishing process
More informationElectrical Wiring Projects
Electrical Wiring Projects Name: Date: Description: Students will learn how to properly install and wire using common industrial devices on an Electrical Board. Students will practice using common electrical
More informationELECTRICAL PANEL SYSTEM
ELECTRICAL PANEL SYSTEM Version 2.3 23-Jul-2016 Copyright 2016 Rancho La Paloma Ministry Center / ClubRust ClubRust and Rancho La Paloma Ministry Center is providing this information and services on its
More informationGross Automation (877)
Carlon Floor Boxes and Covers Round 1-, 2-, and 3-Gang Rectangular Residential Fully Adjustable Drop-In Brass Covers Nonmetallic Covers Carlon Floor Boxes and Covers Contents Adjust-A-Box Residential
More informationPart VIII Electrical GENERAL REQUIREMENTS CHAPTER 33
Part VIII Electrical CHAPTER 33 GENERAL REQUIREMENTS < SECTION E3301 GENERAL E3301.1 Scope. The installation of electrical systems, equipment and components indoors and outdoors that are within the scope
More informationBracket guide. LK Pipe Pole. LK Radiator fixture Uni
Bracket guide LK Radiator fixture Uni LK Radiator fixture Uni c/c 40 (Article no. 481 43 92) LK Radiator fixture Uni c/c 50 (Article no. 481 44 03) LK Pipe Pole (Article no. 481 43 91, 481 43 90) Used
More informationGLOSSARY OF ELECTRICAL INDUSTRY TERMS
A ADD-A-DEPTH RING a means of extending the walls of a device box to the wall surface, providing a barrier between a wiring device and the surrounding wall material. AIR PLENUM a compartment or chamber
More informationUniversal Voice Coil and 70 Volt Door Speaker V / V
PagePac by ISSUE 2 Universal Voice Coil and 70 Volt Door Speaker V-5330120 / V-5330230 Installation Manual 947179 Your PagePac Door Speaker Note: The Door Phone Controller and PagePac 6 systems require
More information05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes
05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes 05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A76 A76 pq^ka^oapi=ommu=k^qflk^i=bib`qof`^i=`lab Δ déåéê~ä=^ééäáå~íáçåë o^`l=ñäççê=äçñéë=~êé=áçé~ääó=ëìáíéç
More informationRange height adjustable assembly
Table of contents Digital handset operation 3 Height adjustable bench kit 4-5 Cable carrier 6 Ganging tray and ganging rail 7 Height adjustable return frame kit 8 Cable entry pole 9 24 and 30 d worksurfaces
More informationModular & Hardwired Hub Assembly to "X" and "Y" Posts
Modular & Hardwired Hub Assembly to "X" and "Y" Posts Hardware Package T-Nut Data jack bracket #6 x 1/4" plastite trilobular screw 1/4-20 x 3/4" socket head cap screw #6-32 x 1/4" pan head screw #10-32
More informationFloor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box
Concealed Service Floor Boxes 663 Series Floor Box 663-SC Multiple service floor box that delivers power, communications and data from standard conduit with no exposed service fitting Result: Open office
More informationInstallation Manual MODEL AE-46
Installation Manual MODEL AE-46 GET TO KNOW YOUR UNIT (BOTTOM OF RACEWAY) 2 5 1 4 6 3 1. CROSS BRACES 2. ELECTRICAL RACEWAY 3. SIDE BRACKETS 4. ELECTRICAL CORD COVER 5. ELECTRICAL OUTLET 6. HOT IRON REST
More informationInstalling LOW EMR Surface mount IS panels in a Custom Cut Sauna TyloHelo Inc.
Installing LOW EMR Surface mount IS panels in a Custom Cut Sauna TyloHelo Inc. The Following instructions will guide you through a typical installation of Low EMR Surface-Mount IS panels in a Custom Cut
More informationST90 SADDLE STITCHER TP10564 MISSING STITCH INSTALLATION MANUAL
ST90 SADDLE STITCHER TP10564 MISSING STITCH INSTALLATION MANUAL OVERVIEW MISSING STITCH INSTALLATION GUIDE The Missing Stitch option is an add-on to the ST-90 saddle stitcher. This unit mounts to the stitch
More informationInstruction page index: Installation Instructions for Bosca Models BOS-XX-C-XX, & BOS-XX-S-XX. Page 1 of 5
Installation Instructions for Bosca Models BOS-XX-C-XX, & BOS-XX-S-XX Page of 5 BOSCA clip-in mount or BOSCA magnetic BOSCA -in mount Instruction page index: Clip-in installation Screw-in installation
More informationThe V2100 Series Steel Raceway provides wiring
V2100 Steel Raceway Two-Piece Surface Raceway The V2100 Series Steel Raceway provides wiring capacities for small to medium size installations. Power or Data/Communication Devices can be wired into the
More informationStud Wall Pages
Pages 125-144 125 Box Mounting Bracket For Electric Box Easily attaches 4" and 411 /16" outlet boxes to metal stud (HS3 switch boxes). Support leg reduces movement of box in wall. Can be attached to metal
More informationPocket Door Kit PD1 / PD2 Installation Instructions. Kit Contents.
Pocket Door Kit PD1 / PD2 Installation Instructions Kit Contents. 1, Create Rough Opening In Stud Wall Construct rough opening ensuring all sides are square and level. Rough opening should be; Height =
More informationInstallation Manual MODEL E-42
Installation Manual MODEL E-42 GET TO KNOW YOUR UNIT 2 (BOTTOM OF RACEWAY) 1 3 1. CROSS BRACES 2. ELECTRICAL RACEWAY 3. ELECTRICAL OUTLET - Stud Finder - 12-14 Level - Tape Measure - Small Flathead Screwdriver
More informationRANGE DIGITAL HANDSET OPERATION. 1. Panel. 2. Initialization Procedure. 3. Move Up & Down. 4. Set Memory Positions. 5. Move to the Memorized Positions
INSTRUCTION SHEET #2577INS PART #1730534 DIGITAL HANDSET OPERATION OPERATION INSTRUCTIONS 1. Panel 1 Button: Preset 1 2 Button: Preset 2 3 Button: Preset 3 S Button: Select Display: Reads in 1 / 2 " Increments
More informationTylo Custom Infrared Sauna Heater Kit Installing LOW EMR Surface mount IS panels
Tylo Custom Infrared Sauna Heater Kit Installing LOW EMR Surface mount IS panels The Following instructions will guide you through a typical installation of Low EMR Surface-Mount IS panels in a Custom
More informationELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL
BELL SYSTEM PRACTICES Plant Series SECTION 508-100-100 Issue 3, October 1970 AT&TCo Standard ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL I. GENERAL 1.01 This section is reissued to: Revise
More informationSteel Raceways BASE SECTIONS. SnapMark SMS3000 Series FITTINGS, CONNECTORS & BOXES RIGID COUPLING COUPLING BLANK END FITTING ENTRANCE END
22 BASE SECTIONS SMS3000 GRAY BASE - 10FT. (3m).050 galvanized steel. Knockout pattern (.5 [12mm] &.75 [19mm]) in back of raceway, 11 (275 mm) on center. Internal area: 4.90 2 (124mm 2 ) (Order SMS3003
More informationInfinity. Surface Mounted Headwall. Installation Instructions. The.
The www.hsiheadwalls.com Infinity Surface Mounted Headwall Installation Instructions Tel: 925.427.7800 Fax: 925.427.0800 support@hsiheadwalls.com Hospital Systems Inc. 750 Garcia Avenue Pittsburg CA 94565
More informationINSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48
INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48 IMPORTANT SAFETY INSTRUCTIONS ---- CAUTION! --- READ THIS FIRST 11500 Melrose Avenue Franklin Park, Illinois 60131 Phone: 847-451-0700
More informationPhone: Installation Instructions
Installation Instructions Multi-Function Step Light GEMINI 3000 SERIES _V1.1 The following instructions are general guidelines. Installation should be performed by a qualified electrician in accordance
More informationSECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION
SECTION 16715 COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION PART 1 - GENERAL 1.01 SECTION DESCRIPTION AND BASIC REQUIREMENTS A. The Electrical Power Distribution System provides power distribution from
More informationAssessment Blueprint
Assessment Blueprint House Wiring Advanced 8063- Online Version 8064- Paper/Pencil Version Copyright 2011. All Rights Reserved. General Assessment Information Home Builders Institute House Wiring Advanced
More informationElectrical requirements for plans on all new homes, additions, remodels & Service upgrades
CHERRY HILLS VILLAGE COLORADO Electrical requirements for plans on all new homes, additions, remodels & Service upgrades Due to the size and uniqueness of homes built in Cherry Hills Village, a policy
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
conduit? 9/8/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Can branch circuits of different services be installed in the same Yes, see 300.3(C)(1) for conductors of different systems
More informationSECTION WIREWAYS FOR RADIOLOGY EQUIPMENT
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 36 WIREWAYS FOR RADIOLOGY EQUIPMENT SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable
More informationP /8 Ring Diameter 90. Trim Ring Mounting Holes P /8. 393/16 Ring Diameter. Stud Minimum
PARTS LIST VARIABLE Top Over Head Support Bracket 1 872070 P4000-SMR Over Head Joiner Bracket 1 VARIABLE Bottom Over Head Bracket 1 79741 P4000-SMR 4 Angled Leg 4 100-00230-14 1/4-20 x 31/2 RD. HD. MS.
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I have a 500 KVA generator, with no overcurrent protection
More informationA. Product Data: For each electrical identification product indicated.
SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationMultiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.
Installation Instructions for 90EMULTI Multiples EM_. GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations. This product can be dimmed with a standard electronic dimmer or a 0-0V
More informationINS T A L L A TIO N INS T R U C TIO N S. Ceiling Mount Track System
Ceiling Mount Track System 10.26.2016 Specifications Ceiling Post: Unassembled 2-7/8 Assembled 1-11/16 7/8 7-9/16 5-7/8 3/8 2 Tubes 1/2 2-3/8 5 Parts and Tools Tools Needed Tape Measure Pencil Drill with
More informationRough-In Frame OVERVIEW OF INSTALLATION PROCEDURE PLANNING GUIDE MODEL IR-105 INSTALLATION DON'TS
Rough-In Frame MODEL IR-105 INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS Model IR-105 Rough-In Frame is to be used with NuTone Model IM-4406 Series Radio/CD Player/Intercom Master Unit. This
More informationSECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL
PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.
More informationPOWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS
POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A
More informationN Nail on mounting H Face bracket for steel and wood stud mounting QT Quick Thread device hole option 16 Bar hanger max 16 joist spacing
FLEXBOX Features: Residential Units Material Characteristics Allied Moulded Flexbox switch and outlet boxes are molded of engineering grades of non-metallic thermoplastic materials. Our Flexbox line of
More informationLCD LIFT Flat Panel Display System Installation Manual. Table of Contents
LCD LIFT Flat Panel Display System Installation Manual Table of Contents Page Installation Overview... 2 Trim Ring Installation... 3 LCD Lift Installation....4 Actuator Switch Installation.5 Top Plate
More informationwith Lamp Install the Housing with Adjustable Bars Installation Instructions for LED E3_-L_DN 1.1 ½ to ¾ ¾ or thicker
Installation Instructions for 90ELED-D Round or Square Type IC, Non-IC Down Light Housing with Lamp LED E_-L_DN. LED - ROUND/ SQUARE GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations.
More informationInterra Installation Manual
Interra Installation Manual Instructions to install the Friant Interra panel system Friant & Associates, LLC Table of Contents Getting Started Introduction... 3 General Tools, Staging & Safety... 4 Before
More informationHi5 s Expert Guide to Specify afix Lecture Hall Tables
Hi5 s Expert Guide to Specify afix Lecture Hall Tables Table Tops Page 2 Table Edges Page 3 Bases Page 4 6 Modesty Panels Page 7 Power Page 8 Wire Management Page 9 ADA Tables Page 10 Finish Choices Page
More informationAnswer Power Beam and Boundary Screen
Answer Power Beam and Boundary Screen 5/16 MAGNETIC 3/8 If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for immediate action by
More informationAssembly Instructions
InTandem Table System November 20 InTandem Table System - Worksurface #4 x/" 4 wood screw power beam Tools Provided T-0 Extended Torx Driver T-25 Torx Driver Additional Tools Required Soft protective
More informationTop Mount Ultra Modern Hanger
Top Mount Ultra Modern Hanger ASSEMBLY INSTRUCTIONS TOP MOUNT ULTRA MODERN HANGER Recommended Tools Level Tape Measure Pencil Drill with 1/8, and 1/4, Drill Bits and Phillips Bit Socket Wrench with 9/16
More informationFraming & Electrical Rough-in for Recess Mount IS Panel System
Framing & Electrical Rough-in for Recess Mount IS Panel System Overview Careful pre-planning and design lay-out are critical to successfully installing a Recess Mount IS (Infra- Sauna) Panel System. The
More informationDesk/Wall-Mount Rack
Desk/Wall-Mount Rack Patent(s) Pending Installation Instructions Post P/N: 119-1752 119-1781 119-1782 119-4014 Frame P/N: 119-1591 119-1754 119-1755 Kit Contents (2) Frames (4) Posts Assembly Hardware
More informationWiring of the Main Distribution Panelboard
Job Sheet 4 Wiring of the Main Distribution Panelboard OBJECTIVE To connect the service-entrance conductors. To ground the main distribution panelboard (MDP). To wire a branch circuit supplying a three-phase
More informationHigh Performance Nylon Wallplates. Nylon Wallplates
Commercial Grade IVORY 80701-I N1-I BLACK 80701-E N1-BK GRAY 80701-GY N1-GRY RED 80701-R N1-RED WHITE 80701-W N1-W BROWN 80701 N1 1-Toggle ALMOND 80701-A N1-A IVORY 80709-I N2-I BLACK 80709-E N2-BK GRAY
More informationRevised April Unit/Standard Number. Proficiency Level Achieved: (X) Indicates Competency Achieved to Industry Proficiency Level
Secondary Task List 100 DEMONSTRATE SAFETY IN THE BUILDING AND PROPERTY MAINTENANCE PROGRAM 101 Demonstrate knowledge of general shop safety. 102 Wear appropriate personal protective clothing. 103 Wear
More informationOXYGEN INSTALLATION. Revision date
12345 1 Hardware List 12345 Flat head wood screw #9 x 7/8 long with #2 Phillips drive, silver Used to attach surfaces and end panels Hex set screw ½-13 x 2 long with 1/4 hex drive, black Used on Legs Hex
More informationVertical Offset Base and Safety Rail System Installation Instructions
Section 5 Vertical Offset Base and Safety Rail System Installation Instructions The vertical offset base and safety rail assembly are designed to be used in residential construction for sloped or flat
More informationInstallation Manual MODEL NE-42
Installation Manual MODEL NE-42 GET TO KNOW YOUR UNIT 1 1. CROSS BRACES - Stud Finder - 12-14 Level - Tape Measure - Small Flathead Screwdriver Tools Needed: - Electric Drill (with 1/4 & 1/8 drill bit)
More informationGENERAL SUBSCRIBER SERVICES TARIFF Pembroke Telephone Company, Inc. Third Revised Contents Sheet 1 Cancels Second Revised Contents Sheet 1
GENERAL SUBSCRIBER SERVICES TARIFF Pembroke Telephone Company, Inc. Section N Third Revised Contents Sheet 1 Cancels Second Revised Contents Sheet 1 N. CONNECTION WITH CERTAIN FACILITIES AND/OR EQUIPMENT
More informationSingle Sided Height Adjustable Benching
Single Sided Height Adjustable Benching Bit Holder Power Drill Long # Square Drive Bit 5mm Hex Drive Bit T-30 Torx Drive Bit Hex Key -.5mm (Provided) SERIES 5 Hex Key - 3mm Socket Adaptor (or) If you have
More informationBELL. RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project
SOLAR RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project Commercial, Industrial and Residential Electrical Products RACO
More informationSubject: P0052 Bed Locator Installation Instructions
Subject: P0052 Bed Locator Installation Instructions Tools required: Standard drill 1/4" diameter drill bit Phillips head screwdriver Screwdriver 5/16" hex nut driver Tape measure 4' (122 cm) level Power
More informationOriginal Gallery System
GAllery System Art Displays Original Gallery System a Gallery System product Here s everything you need to know to get started with your Gallery System Art Hanging System GS getting started To install
More informationULTRA SPACE SAVER Installation Instructions
Installation Instructions The Ultra Space Saver has several steps for installation. Note that the single and double sided setups and parts are different. Make sure you follow the instructions according
More informationMounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome
VIVOTEK SD83XXE Speed Dome Mounting Accessories AM-116/117 Pendant Pipe AM-118 Pendant Head AM-221 Gooseneck AM-231 Parapet Mount AM-519 Pendant Adaptor Installation Guide Corresponding part numbers: AM-116:
More informationLedgewood Farm greenhouse. construction
Ledgewood Farm greenhouse How do I Start? construction to I m Finished! Post layout The string will be 7 above the ground and the posts will be driven until the proper drill hole is at the string. Spacing
More informationINSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S THE MAVERICK HANGER R H
INS T A L L A TIO N INS T R U C TIO N S THE MAVERICK HANGER 10.6.2016 PARTS INSTALLATION SPECIFICATIONS AND TOOLS INSTRUCTIONS 2-1/4" 2-7/8 11-3/8" 1/4" 2-1/8 PARTS INSTALLATION AND INSTRUCTIONS TOOLS
More informationSystem Components and Accessories
OutBack Panel Mount Breakers Panel mounted hydraulic-magnetic type breakers that can be used for DC sources, inverters or load circuits. Model Current Voltage Branch Terminals Width Rating Rating Circuit
More informationInstallation Manual MODEL ANE-42
Installation Manual MODEL ANE-42 GET TO KNOW YOUR UNIT 1 2 1. CROSS BRACES 2. SIDE BRACKETS - Stud Finder - 12-14 Level - Tape Measure - Small Flathead Screwdriver Tools Needed: - Electric Drill (with
More information1. TRACER WIRE. I. Application. Material Specification. Page 1 of 16
Page 1 of 16 1. TRACER WIRE I. Application A Tracer Wire must be installed on all non-metallic watermains and sanitary force mains. The wire shall be installed in such a manner as to be able to properly
More informationOutdoor Enclosure. VIVOTEK Pan/Tilt & Fixed Dome Series. Installation Guide
VIVOTEK Pan/Tilt & Fixed Dome Series Outdoor Enclosure Using AE-131/-132 Outdoor Enclosure, AE-151 Outdoor Enclosure, AM-114 Pendant Head (outdoor), AM-116 and AM-117 Pendant Pipes, AM-221 Gooseneck, AM-212
More informationMultiTable Mod-E 2 Electric Standing Desk
The Height of Healthy Design MultiTable Mod-E 2 Electric Standing Desk ASSEMBLY INSTRUCTIONS MultiTable Mod-E 2 Electric Standing Desk Frame PARTS AND TOOLS PLEASE REVIEW these instructions before beginning
More informationIn-Wall Mounting Kit. Grandstream Networks, Inc. Quick Reference Guide. (GDS3710 NOT Included)
Grandstream Networks, Inc. 126 Brookline Ave, 3rd Floor Boston, MA 02215. USA Tel : +1 (617) 566-9300 Fax: +1 (617) 249-1987 www.grandstream.com For Warranty and RMA information, please visit www.grandstream.com
More informationLINESSE LINEAR LUMINAIRE 3 CEILING MOUNT CM2420
Linesse Linear Luminaire 3 Ceiling Mount LINESSE LINEAR LUMINAIRE 3 CEILING MOUNT Page 2: Warnings Page 3: Mounting Configurations Page 4: Power Feed Page 5: Surface Mounting Page 6: Threaded Rod Mounting
More informationAUXILIARY FRAMING AND ACCESSORIES
CUSTOM CABINETS & RACKS STRUT AND ACCESSO- RIES JUNCTION KITS ANGLE AND BRACE KITS SPLICE KITS BRACE KITS INSTALLATION KITS WALL ANGLE KITS RUBBER END CAPS SUPPORT INSTALLATION AND SUPPORT KITS STANCHION
More informationINSTALLATION MANUAL VERITY. friant.com/verity
INSTLLTION MNUL VERITY friant.com/verity 2 VERITY INSTLLTION MNUL General Information... 4 Safety & Support... 5 Installation Tools... 6 Staging & Installation... 7 Stand lone Units Single-Sided Structure...
More informationLightplane 3.5 Recessed
INSTALLATION INSTRUCTIONS Lightplane 3.5 Recessed LP3.5R Recessed Ceiling IMPORTANT SAFETY INSTRUCTIONS When installing or using this fixtures basic safety precautions must be followed. Read all instructions
More informationCustomer Requirements RF Antenna Installations
Application Terms Attachment requirements and clearances on the Pole for Radio Frequency (RF) antenna equipment installations. This standard is intended to allow electrical workers to perform their normal
More informationSMARTfit Functional and Brain Fitness Training Multi-Station Trainer Installation for Stud and Concrete Walls (US)
SMARTfit Functional and Brain Fitness Training Multi-Station Trainer Installation for Stud and Concrete Walls (US) 2017 SMARTfit, Inc. www.smartfitinc.com 1 Unlike other fitness equipment which may require
More informationEOS LED Surface Mounted Luminaire
Installation Instruction Sheet INSTALLATION INSTRUCTIONS FOR JOINING AND SUSPENDING FIXTURES WARNING WARNING To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions,
More informationNEW OR UPGRADED ELECTRICAL SERVICE
NEW OR UPGRADED ELECTRICAL SERVICE The following steps summarize the general process and procedures necessary for CVEA to complete construction of a new or upgraded service. Variances may be necessary
More informationPCS. Patient Security Service Console. Installation Instructions.
www.hsiheadwals.com PCS Patient Security Service Console Installation Instructions Tel: 925.427.7800 Fax: 925.427.0800 support@hsiheadwalls.com Hospital Systems Inc. 750 Garcia Avenue Pittsburg CA 94565
More informationModular Gazebo Kit Series Victorian / Queen Anne 9
Octagonal CUPOLA louvered (electrical optional) Modular Gazebo Kit Series Victorian / Queen Anne 9 with SINGLE-TIERED Roof Lumber: Western Red CEDAR #1 (Cabinet) or #D and Better (Carpentry) Shingles:
More informationWESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)
WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) THREE-PHASE SUBSURFACE UNDERGROUND COMMERCIAL DISTRIBUTION (UCD) TRANSFORMER NOTE: This "Guide" summarizes the opinions, recommendations, and practices
More informationFor all Davis weather consoles including Vantage Pro2,
USR MANUAL Universal Shelter For all Davis weather consoles including Vantage Pro2, Vantage Pro2 Plus R, Vantage Vue, nvoy 8X, and Weather nvoy Product Number 6618 R Davis Instruments, 3465 Diablo Avenue,
More informationYes 20 Charging Wall Cabinet for Tablets
Built with Anthro-DNA Owner's Manual for Yes 20 Charging Wall Cabinet for Tablets Part # YESCABGMPW Components at a Glance 1 2 4 5 8 7 10 3 6 9 Front of Cabinet (closed) 1. Locking front door to User area.
More informationPOWER TRACE TM TASCO, INC.
POWER TRACE TM Instruction Manual PTL610 TASCO, INC. HOW YOUR POWER TRACE TM OPERATES The Power Trace TM is composed of two primary components: the Receiver and the Transmitter. When the Transmitter is
More informationMODELS: AE46, AE42, E46, E42, ANE46, ANE42, NE46, NE42
Installation Manual MODELS: AE46, AE42, E46, E42, ANE46, ANE42, NE46, NE42 TABLE OF CONTENTS SWIVEL UNITS (AE46, AE42, ANE46, ANE42)...pg.3 NON-SWIVEL UNITS (E46, E42, NE46, NE42)...pg.11 ELECTRICAL INSTRUCTIONS...pg.17
More information13MM FLAT WRENCH FOR LEVELING THE GLIDES OF STRUCTURE 6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME
1 TOOLS REQUIRED: MOVING CART/DOLLY FOR TRANSPORTING PANELS, ROOF, AND POSTS TWO 9 FT. STEP LADDERS FOR INSTALLING ROOF & PANELS REVERSIBLE RATCHET 1/4 DRIVE FOR CORNER SCREWS ON TOP TRAVERSE BEAMS ALTERNATIVE
More informationOFS ED-6C Instruction Sheet LIGHTGUIDE CROSS-CONNECT Comcode: LGX DISTRIBUTING FRAME INSTALLATION
OFS ED-6C321-50 636-299-104-01 Instruction Sheet LIGHTGUIDE CROSS-CONNECT Comcode: 845 866 367 LGX DISTRIBUTING FRAME INSTALLATION This instruction sheet is intended for use with the installation of an
More informationTOOLS REQUIRED: HARDWARE INCLUDED: 13MM FLAT WRENCH FOR LEVELING THE STRUCTURE RATCHET WITH 5MM HEX BIT FOR CORNER SCREWS ON TOP TRAVERSE BEAMS
1 TOOLS REQUIRED: RATCHET WITH 5MM HEX BIT FOR CORNER SCREWS ON TOP TRAVERSE BEAMS 13MM FLAT WRENCH FOR LEVELING THE STRUCTURE RUBBER MALLET FOR INSERTING PANELS 8MM HEX BIT WITH EXTENSION FOR HEX BOLT
More informationArlington Industries, Inc.
rlington Industries, Inc. www.aifittings.com E-mail: sales@aifittings.com 800/233-4717 FX 570/562-0646 Steel Stand-Off racket 20 gauge steel stand-off bracket provides rigid support and spacing for a 4x4
More informationFooter & Base Plate Assembly. installation guide. ILINE power/data beam
Phase Footer & Base Plate Assembly installation guide ILINE power/data beam Phase Materials and Tools. ILINE Postsleeve Components Top Cap Data Face Plate Post Sleeve Post Sleeves shipped with orders after
More informationHigh-impact resistant thermoplastic construction
Residential Grade Devices Receptacles TradeMaster Receptacles Tamper-Resistant Receptacles High-impact resistant thermoplastic construction Extra-long strap, Quickloop wire looping aid Long-term blade
More informationFigure A. Figure B. Figure C. Figure D
Xsite 1 Power/Data Tile and Components Tools Required Tape Measure Cordless Drill/Driver #2 Phillips Screw driver bit Rubber Mallet Flat Blade Screwdriver Figure A Hardware Required Provided as shown Installation
More informationULTRA SPACE SAVER SQUARED Installation Instructions
Installation Instructions The Ultra Space Saver Squared has several steps for installation. Note that the single and double sided setups and parts are different. Make sure you follow the instructions according
More informationThanks for shopping with Improvements! Deluxe 10 Closet Organizer (12 deep) Item #461609
Thanks for shopping with Improvements! Deluxe 10 Closet Organizer (12 deep) Item #461609 To order, call 1-800-642-2112 West Chester, OH 45069 0114 If you have questions regarding this product, call 1-800-642-2112
More informationSMARTfit High Intensity Cognitive Training. SMARTfit Trainer Installation Manual for Stud and Concrete Walls Revision 1.3
SMARTfit High Intensity Cognitive Training SMARTfit Trainer Installation Manual for Stud and Concrete Walls Revision 1.3 2015 Unlike other fitness equipment which may require additional insurance, SMARTfit
More informationSECTION H -- GROUNDING AND BONDING
Section, ATT-TP-76300 SECTION -- GROUNDING AND BONDING CONTENTS PAGE 1. GENERAL... -2 1.1. Introduction... -2 1.2. Definitions... -2 2. GROUNDING SYSTEM CONDUCTORS AND CONNECTIONS... -4 2.1. General Requirements...
More information