3 ~ ~ - METL DISCLAIMER: These details are based on industry accepted practices and provide a guideline for proper insulated metal panel and component installation. The location of vapor barriers and associated sealants shown in these details is based on standard design practices for commercial industrial applications for most U.S. and Canadian climatic zones. The default vapor barrier location is on the warm side in winter (the interior side of the panels). For projects located in extremely cold climates, exposed to high wind-driven rain or unusual interior conditions (sustained temperatures below 65 f), it may be advisable to modify the vapor barrier (joint sealant) location, or to add optional exterior joint sealants. It is the sole responsibility of the project architect to verity vapor barrier location. insulation required by code and HVAC equipment/ventilation requirements to allow proper air flow and the prevention of condensation. It is also the sole responsibility of the project architect to determine project-specific design loads. Meti-Span Technical Services is available to verity allowable panel spans and fastening requirements when provided with this information. The details contained herein show side joint fastening only. Please contact Meti-Span technical services for project-specific fastening requirements. All structural supports are shown for clarity only, and are not provided by Meti-Span. DISCLAIMER CI-CF-INF0-1 DATE:

4 - Butyl caulk: For commerical/industrial projects the caulk is usually applied to the interior joint female pocket (see DISCLAIMER). Butyl caulk is also used to create ~~marriage beads.. which tie the panel sidejoint vapor seals to panel endjoint vapor seals. Butyl caulk is considered II non-skinning.., which means it stays soft, flexible, and does not harden. Butyl caulk is for unexposed areas only, and cannot be used where it will be exposed to weather or sunlight Butyl sealant tape: Applied between flashings and panels to form a weathertight seal. All fasteners penetrating the flashing must be inserted through the sealant tape. Urethane caulk: Used in lieu of butyl sealant where there is exposure to the elements. It is recommended for lapped trims, exposed perimeter seals at framed openings or to seal between different construction materials, such as metal to concrete. Panel fasteners: Insulated metal panel fasteners are generally either self-drilling/self-tapping (also known as TEK screws), or self-tapping (also known as B point screws). TEK Fasteners contain a built-in drill point, and do not require pre-drilling. They are the quickest and easiest way to attach panels to light-medium gauge supports. B Point fasteners require a two-step operation: First holes are pre-drilled into the panel and structural support with an appropriate sized bit, then the fastener is inserted into the hole and tightened. B points are typically used to attach panels to medium-heavy gauge supports that are not penetrable by TEK fasteners. It is important that the pre-drilled holes are sized correctly for the fasteners to achieve proper pullout values. Bulb-lite Rivets: Are similar to expansion fasteners, and are used where back fastening of the panels to structural supports is required. Holes must be pre-drilled with a 5/16.. diameter. The grip range of the rivets must be matched to the thickness of the structural support to ensure proper fastening. SEALANTS & FASTENERS CI-CF-INF

5 A Divioion of NCI Grou,, 1 no. ~ J~ Jr-~ ~r ~J~ CF-42, CF-36 FLUTE/MESA ;;00 ~ ~ ~------~~ ~? CF-42, CF-36, CF30 MESA/MESA -~--r~ E_E~ ~~~~ ~~~ CF-36A, CF-30A ARCHITECTURAL FLAT/MESA,;; ~ ~ ~ ~ ~? CF-36, CF-42 SANTA FE _~_~EEND------~~ ~~? CF-42, CF-36, CF-30 STRIATED/MESA PANEL PROFILES CI-CF-JT -01 DATE:

6 A Divioion of NCI Grou,, 1 no. 36" 7.2 INSUL-RIB J \_/ 36" LS 36 \_/, \_) 1~ -~ ''. """ '. """ '. """ "0. """ '. """ '. """ 0. 0) CF-36, CF-42 TUFF-CAST, TUFF-WALL PANEL PROFILES CI-CF-JT -02 DATE:

7 14 GA. PANEL CLIP WI 1 /4" HWH EACH WALL SUPPORT METL INTERIOR WALL SUPPORT CLIP AND FASTENER ASSEMBLY JOINT SEALANT INTERIOR WALL SUPPORT OPTIONAL JOINT SEALANT SEE DETAIL "A" JOINT SEALANT APPLICATION NON-SKINNING 1 /4" UNIFORM BEAD SPECIFIED OPTIONAL JOINT SEALANT DETAIL A INTERIOR WALL SUPPORT 1/B" MAX@ JOINT CF PANEL JOINT DETAILS CI-CF-JT -03 DATE:

8 INTERIOR SURFACE METL A Divioion of NCI Grou,, I no.././././ EXTERIOR SURFACE WALL SUPPORT 14 GA. CLIP 1/4" HWH FASTENERS WALL SUPPORT (14GA. MINIMUM) PANEL EACH WALL SUPPORT ATTACHMENT- SIDEJOINT PRE-ENGINEERED SUPPORT CI-CF-FSTN-01A DATE:

9 INTERIOR SURFACE METL EXTERIOR SURFACE STRUCTURAL STEEL 14 GA. CLIP STRUCTURAL STEEL 1/4" HWH FASTENERS I I I I I I I I I I I I 14 GA. CLIP W/FASTENERS ATTACHMENT- SIDEJOINT STRUCTURALSTEELSUPPORT CI-CF-FSTN-01 B DATE:

10 2 HOLE GIRT CLIP DOME HEAD BULB-TITE RIVETS METL * INSTALL THROUGH GIRT CLIPS INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL INTERIOR SIDE STRUCTURAL STEEL 14 GA. CLIP 1/4" HWH FASTENERS BULB-TITE RIVET GIRT CLIP GIRT CLIP BULB-TITE RIVET STRUCTURAL STEEL ATTACHMENT- BACK FASTENED WI GIRT CLIPS CI-CF-FSTN-01 C DATE:

11 DOME HEAD BULB-TITE RIVETS METL * INSTALL THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH STEEL INTERIOR SIDE WALL SUPPORT 14 GA. CLIP 1/4" HWH FASTENERS BULB-TITE RIVET WALL SUPPORT BULB-TITE RIVET I I I I I I I I I I I 14 GA. CLIP W/FASTENERS ATTACHMENT- BACK FASTENED WI RIVETS CI-CF-FSTN-01 D DATE:

12 (FP1) FASTENING PATTERN 1 SIDE JOINT FASTENING DIMENSION IS FROM FEMALE EDGE +/- 1.5" 1 0.5" (FP2) FASTENING PATTERN 2 SIDE JOINT FASTENING AND ONE DOME HEAD BULB-TITE RIVET INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) FASTENING PATTERNS CI-CF-FP 1-2 DATE:

13 DIMENSION IS FROM FEMALE EDGE +/- 1.5" 1 0.5" 1 0.5" (FP3) FASTENING PATTERN 3 SIDE JOINT FASTENING AND TWO DOME HEAD BULB-TITE RIVETS DIMENSION IS FROM FEMALE EDGE +/- 1.5" INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL 1 0.5" 1 0.5" 1 0.5'' (FP4) FASTENING PATTERN 4 SIDE JOINT FASTENING WITH THREE DOME HEAD BULB-TITE RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) FASTENING PATTERNS CI-CF-FP 3-4 DATE:

14 DIMENSION IS FROM FEMALE EDGE +/- 1.5" 5.25" 1 0.5'' 1 0.5" 1 0.5" 5.25" (FP5) FASTENING PATTERN 5 SIDE JOINT FASTENING AND BACK FASTENING WITH FOUR DOME HEAD BULB-TITE RIVETS DIMENSION IS FROM FEMALE EDGE +/- 1.5" INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL 1 0.5" (FP6) FASTENING PATTERN 6 SIDE JOINT FASTENING AND ONE GIRT CLIP WITH TWO DOME HEAD BULB-TITE RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) FASTENING PATTERNS CI-CF-FP 5-6 DATE:

15 DIMENSION IS FROM FEMALE EDGE +/- 1.5" 1 0.5" 1 0.5" (FP7) FASTENING PATTERN 7 SIDE JOINT FASTENING AND TWO GIRT CLIPS WITH FOUR DOME HEAD BULB-TITE RIVETS DIMENSION IS FROM FEMALE EDGE +/- 1.5" INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL 1 0.5" 1 0.5" 1 0.5'' (FP8) FASTENING PATTERN 8 SIDE JOINT FASTENING WITH THREE GIRT CLIPS WITH SIX DOME HEAD BULB-TITE RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) FASTENING PATTERNS CI-CF-FP 7-8 DATE:

16 8.4" 8.4" 8.4" 8.4" 8.4" (FP9) FASTENING PATTERN 9 WITH FOUR SELF-TAPPING SCREWS WITH MIN. 20 GA. NEOPRENE BONDED WASHER 8.4" 8.4" 8.4" 8.4" 8.4" ~~ (FP1 0) FASTENING PATTERN 10 WITH FIVE SELF-TAPPING SCREWS WITH MIN. 20 GA. NEOPRENE BONDED WASHER I - ~ (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) FASTENING PATTERNS CI-CF-FP 9-10 DATE:

17 14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS BASE TRIM [F3369] 1 /8" Q> 12"0.C. [14] CONTINUOUS BASE ATTACHMENT (NOT BY PANEL MANUFACTURER} BUYTL SEALANT #12 PANCAKE STITCH FASTENER [12A] FINISH FLOOR BASE FLASHING CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71 OOBWH] 4 <C1 <1 CONC. FASTENERS BASE ATTACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE BCLIP FLASHING FASTENER FASTENER FASTENER 2" F PNC 1724PNC 1816PNC 2.5" F PNC 1732PNC 1824PNC 2.75" F PNC 1732PNC 1824PNC 3" F PNC 1732PNC 1824PNC 4" F PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-BE-02 WI NOTCHED SLAB DATE:

18 14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS 1 /8"!II 12"0.C. [14] CONTINUOUS BASE ATTACHMENT BUYTL SEALANT #12 PANCAKE STITCH FASTENER [12A] FINISH FLOOR CONC. FASTENERS BASE FLASHING CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT BASE ATTACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT <J URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE BCLIP FLASHING FASTENER FASTENER FASTENER 2" F PNC 1724PNC 1816PNC 2.5" F PNC 1732PNC 1824PNC 2.75" F PNC 1732PNC 1824PNC 3" F PNC 1732PNC 1824PNC 4" F PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-BE-04 WI NOTCHED SLAB- ALT. DATE:

19 14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS BASE TRIM [F3369] 1 /8" 16 12"0.C. [14] CONTINUOUS BASE ATIACHMENT #12 PANCAKE STITCH FASTENER [12A] FINISH FLOOR CONC. FASTENERS BASE FLASHING BASE ATIACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE BCLIP FLASHING FASTENER FASTENER FASTENER 2" F PNC 1724PNC 1816PNC 2.5" F PNC 1732PNC 1824PNC 2.75" F PNC 1732PNC 1824PNC 3" F PNC 1732PNC 1824PNC 4" F PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-BE-06 WI DRIP TRIM DATE:

20 14 GA. PANEL CLIP [4633GNC] 1/4" HWH CLIP FASTENERS CONTINUOUS BASE ATIACHMENT #12 PANCAKE STITCH FASTENER [12A] 1/8" ~ [14] BASE FLASHING FINISH FLOOR CONC. FASTENERS BASE ATIACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT PANEL SUPPORT ANGLE CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE B CLIP FLASHING FASTENER FASTENER FASTENER 2" F PNC 1724PNC 1816PNC 2.5" F PNC 1732PNC 1824PNC 2.75" F PNC 1732PNC 1824PNC 3" F PNC 1732PNC 1824PNC 4" F PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-BE-07 WI EDGE TRIM DATE:

21 - r- T -r -TV-,- 14 GA. PANEL CLIP CONTINUOUS BASE ATIACHMENT [4633GNC] ~ 1 ~ 1/4" HWH CLIP FASTENERS ~! / BASE ATIACHMENT ~ ~---::1) SET IN CONTINUOUS ~ ~ 1 / BEAD OF URETHANE SEALANT I-,.. [HW540] 1/8"!II ~. [14] ~ D Ll BASE FLASHING ~ L...J..._:;;;;;;;;~'Jif:J I : v I FINISH FLOOR ~ Ll CONC. FASTENERS CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE B CLIP FLASHING FASTENER FASTENER FASTENER 2" F PNC 1724PNC 1816PNC 2.5" F PNC 1732PNC 1824PNC 2.75" F PNC 1732PNC 1824PNC 3" F PNC 1732PNC 1824PNC 4" F PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-BE-08 WI BASE SUPPORT DATE:

22 FIELD NOTCH HEM(S} AS REQUIRED (2) BEADS URETHANE SEALANT ~~ NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - BASE CI-CF-EL-8 DATE:

23 14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS WI PER GASKET [7800VGR] CONTINUOUS BASE ATTACHMENT BUYTL SEALANT #12 PANCAKE STITCH FASTENER [12A] FINISH FLOOR FIELD DRILL 3/8" MIN. WEEP 24" o.c. BASE EXTRUSION SPLICE BAR [9495A] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT CONC. FASTENERS BASE ATTACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE BCLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9405A 1616PNC 1724PNC 1816PNC 2.5" 9406A 1624PNC 1732PNC 1824PNC 3" 9407A 1624PNC 1732PNC 1824PNC 4" 9404A 1632PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-EB-01 WI NOTCHED SLAB, EXTRUSION DATE:

24 14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS WIPER GASKET [7800VGR] BASE EXTRUSION FIELD DRILL 3/8" f/j MIN. WEEP o.c. SPLICE PLATE [9495A] [71 OOBWH] CONTINUOUS BASE ATIACHMENT #12 PANCAKE STITCH FASTENER [12A] FINISH FLOOR CONC. FASTENERS BASE ATIACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71008WH] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE BCLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9405A 1616PNC 1724PNC 1816PNC 2.5" 9406A 1624PNC 1732PNC 1824PNC 3" 9407A 1624PNC 1732PNC 1824PNC 4" 9404A 1632PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-EB-02 WI EXTRUSION DATE:

25 CORNER TRIM [F5140] 1 /4" PANCAKE EACH SUPPORT 1 /8" 0 [14] SEALANT TAPE (AS REQUIRED) EXPANDABLE FOAM INSULATION CORNER TRIM REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T CORNER TRIM PANCAKE HEAD TYPE3 2" F PNC 2.5" F PNC 2.75" F PNC 3" F PNC 4" F PNC OUTSIDE CORNER CI-CF-CE-01 WI FLUSH TRIM DATE:

26 1 /8" 16 [14] 1 /8" 1/J o.c. [14] CORNER TRIM [F5140] 1 /4" PANCAKE EACH SUPPORT SEALANT TAPE (AS REQUIRED) REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T CORNER TRIM PANCAKE HEAD TYPE3 2" F PNC 2.5" F PNC 2.75" F PNC 3" F PNC 4" F PNC INSIDE CORNER CI-CF-CE-03 WI FLUSH TRIM DATE:

27 'ol a.. :5 C\J~ a: I-- FIELD NOTCH HEM(S) AS REQUIRED (2) BEADS URETHANE SEALANT a.. :5 a: I-- NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - CORNER CI-CF-EL-C DATE:

28 Atl... I::::M IV SUPPORTS ~ FEMALE CORNER EXTRUSION [9430A] WI PER GASKET [7800VGR] #12 PANCAKE STITCH EACH SUPPORT [12A] 1 /4" PANCAKE EACH SUPPORT FIELD MITER PANEL MALE CORNER EXTRUSION [9425A] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T MALE CORNER FEMALE CORNER PANCAKE HEAD EXTRUSION EXTRUSION TYPE3 2" 9425ANC 9430ANC 1424PNC 2.5" 9425ANC 9431ANC 1432PNC 3" 9425ANC 9432ANC 1432PNC 4" 9429ANC 9433ANC 1440PNC OUTSIDE CORNER CI-CF-EC-01 WI TWO PIECE EXTRUSION DATE:

29 MALE CORNER EXTRUSION #12 PANCAKE STITCH EACH SUPPORT [12A] FEMALE CORNER EXTRUSION 1/4" PANCAKE SUPPORT WIPER GASKET [7800GVR] REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T MALE CORNER EXTRUSION FEMALE CORNER EXTRUSION PANCAKE HEAD TYPE ANC 9440ANC 1424PNC INSIDE CORNER WI TWO PIECE EXTRUSION CI-CF-EC-02 DATE:

30 14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS EXTERIOR HEAD TRIM [F5044] CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] #12 PANCAKE STITCH SCREW [12A] URETHANE SEALANT [HW540] 1 /8" ~ POP RIVET 8" D.C. [14] INTERIOR HEAD TRIM SUPPORT WINDOW /DOOR/LOUVER/FRAM lng URETHANE SEALANT [HW540] PERIMETER SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR TYPE 3 CLIP TYPES CLIP TYPE BCLIP HEAD TRIM FASTENER FASTENER FASTENER 2" F PNC 1724PNC 1816PNC 2.5" F PNC 1732PNC 1824PNC 2.75" F PNC 1732PNC 1824PNC 3" F PNC 1732PNC 1824PNC 4" F PNC 1740PNC 1832PNC CI-CF-HD-01 HEAD W/ TWO PIECE TRIM DATE:

31 14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS EXTERIOR HEAD TRIM [F5044] CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] #12 PANCAKE STITCH SCREW [12Al SUPPORT URETHANE SEALANT [HW540] 1 /8" ~ POP RIVET 8" O.C. [14] HEAD TRIM (OPTIONAL) URETHANE SEALANT [HW540] INTERIOR HEAD TRIM REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR TYPE 3 CLIP TYPES CLIP TYPE BCLIP HEAD TRIM FASTENER FASTENER FASTENER 2" F PNC 1724PNC 1816PNC 2.5" F PNC 1732PNC 1824PNC 2.75" F PNC 1732PNC 1824PNC 3" F PNC 1732PNC 1824PNC 4" F PNC 1740PNC 1832PNC O.H. DOOR HEAD CI-CF-HD-02 WI TWO PIECE TRIM DATE:

32 FIELD NOTCH HEM(S) AS REQUIRED (2) BEADS URETHANE SEALANT ,.~ NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - TWO PIECE HEAD CI-CF-EL-H DATE:

33 14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS WIPER GASKET [7BOOVGR] EXTERIOR HEAD EXTRUSION [9415A] INTERIOR HEAD EXTRUSION CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] #12 PANCAKE STITCH SCREW [12A] FIELD DRILL 3/8" MIN. WEEP 24" o.c. URETHANE SEALANT [HW540] PERIMETER SEALANT SUPPORT WIN DOW /DOOR/LOUVER/FRAMING REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATIACHMENT FASTENERS. T INTERIOR HEAD TYPE 3 CLIP TYPE 5 CLIP TYPE B CLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9420A 1616PNC 1724PNC 1816PNC 2.5" 9421A 1624PNC 1732PNC 1824PNC 3" 9422A 1624PNC 1732PNC 1824PNC 4" 9423A 1632PNC 1740PNC 1832PNC CI-CF-EH-01 HEAD W/ TWO PIECE EXTRUSION DATE:

34 INTERIOR HEAD EXTRUSION 14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS WI PER GASKET [7800VGR] EXTERIOR HEAD EXTRUSION [9415A] CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] #12 PANCAKE STITCH SCREW [12A] SUPPORT FIELD DRILL 3/8" MIN. WEEP 24" O.C. HEAD TRIM (OPTIONAL) URETHANE SEALANT [HW540] PERIMETER SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATIACHMENT FASTENERS. T INTERIOR HEAD TYPE 3 CLIP TYPE 5 CLIP TYPE B CLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9420A 1616PNC 1724PNC 1816PNC 2.5" 9421A 1624PNC 1732PNC 1824PNC 3" 9422A 1624PNC 1732PNC 1824PNC 4" 9423A 1632PNC 1740PNC 1832PNC O.H. DOOR HEAD CI-CF-EH-02 WI TWO PIECE EXTRUSION DATE:

35 SUPPORT 1/4" PANCAKE FASTENER (NOT TO EXCEED 5'-0" O.C.) WINDOW /LOUVER/DOOR/FRAMING INTERIOR JAMB TRIM PERIMETER SEALANT BUTYL TAPE [7300BGR] 1/8" Ill [14] EXTERIOR JAMB TRIM [F27] URETHANE SEALANT [HW540] 1/8" Ill POP RIVET 8" O.C. [14] URETHANE SEALANT [HW540] REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR JAMB TRIM PANCAKE HEAD TYPE3 211 F PNC F PNC F PNC 311 F PNC 411 FF PNC JAMB W/ TWO PIECE TRIM CI-CF-JB-01 DATE:

36 SUPPORT WINDOW /LOUVER/DOOR/FRAMING 1 /4" PANCAKE FASTENER (NOT TO EXCEED 5'-0" O.C.) PERIMETER SEALANT BUTYL TAPE [7300BGR] 1 /8" rij [14] FLAT JAMB TRIM REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T FLAT JAMB TRIM PANCAKE HEAD TYPE3 211 F PNC F PNC F PNC 311 F PNC 411 F PNC CI-CF-JB-02 JAMB W/ DEEP TRIM DATE:

37 FIELD NOTCH HEM(S) AS REQUIRED (2) BEADS URETHANE SEALANT NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - TWO PIECE JAMB CI-CF-EL-J DATE:

38 SUPPORT 1 /4" THRU FASTENER (NOT TO EXCEED 5'-0" O.C.) WINDOW /LOUVER/DOOR/FRAM lng #12 PANCAKE STITCH SCREW@ ENDS [12A] PERIMETER SEALANT URETHANE SEALANT [HW540] WIPER GASKET [7800VGR] FEMALE JAMB EXTRUSION MALE JAMB EXTRUSION [9415A] REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T FEMALE TYPE 3THRU TEK5THRU TYPE BTHRU JAMB EXTRUSION FASTENER FASTENER FASTENER A 1424PNC 1732PNC 1824PNC A 1432PNC 1740PNC 1832PNC A 1432PNC 1740PNC 1832PNC A 1440PNC 1748PNC 1832PNC CI-CF-EJ-01 JAMB W/ EXTRUSION DATE:

39 SUPPORT 1 /4" PANCAKE FASTENER (NOT TO EXCEED 5'-0" O.C.) [71 OOBWH] JAMB WRAP TRIM (OPTIONAU INTERIOR JAMB TRIM [71 OOBWH] URETHANE SEALANT [HW540] BUTYL TAPE [71 OOBWH] 1/8" ~ o.c. [14] 1/8" ~ POP [14] URETHANE SEALANT [HW540] EXTERIOR JAMB TRIM [F27] REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR JAMB TRIM PANCAKE HEAD TYPE3 211 F PNC F PNC 311 F PNC 411 F PNC O.H. DOOR JAMB CI-CF-DJ-01 WI TWO PIECE TRIM DATE:

40 SUPPORT 1 /4" THRU FASTENER (NOT TO EXCEED 5'-0" O.C.) #12 PANCAKE STITCH SCREW@ ENDS [12A] JAMB WRAP TRIM ~ (OPTIONAU URETHANE SEALANT [HW540] WIPER GASKET [7800VGR] FEMALE JAMB EXTRUSION MALE JAMB EXTRUSION [9415A] REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T FEMALE TYPE 3THRU TEK5THRU TYPE BTHRU JAMB EXTRUSION FASTENER FASTENER FASTENER A 1424PNC 1732PNC 1824PNC A 1432PNC 1740PNC 1832PNC A 1432PNC 1740PNC 1832PNC A 1440PNC 1748PNC 1832PNC O.H. DOOR JAMB CI-CF-ED-01 WI EXTRUSION DATE:

41 - #12 PANCAKE STITCH 12" O.C. PERIMETER SEALANT SILL TRIM (SEE CHART] ~ WINDOW /LOUVER/DOOR/FRAM lng / I. tr======='lf SUPPORT ~ A ~ 1 /8" ~ RIVETS 1 Rl O.C. [14] FLASHING SEALANT TAPE ~ [7405BWH] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] ~' CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT '== SEALANT = 1 /4" HWH CLIP FASTENERS 14 GA. PANEL CLIP [4633GNC] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T SILL TRIM TYPE 3 CLIP TYPES CLIP TYPE BCLIP FASTENER FASTENER FASTENER 2" F PNC 1724PNC 1816PNC 2.5" F PNC 1732PNC 1824PNC 2.75" PNC 1732PNC 1824PNC 3" F PNC 1732PNC 1824PNC 4" F PNC 1740PNC 1832PNC SILL DETAIL CI-CF-SL -01 WI FLAT TRIM DATE:

42 (2) BEADS URETHANE SEALANT FIELD NOTCH HEM(S) AS REQUIRED NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - SILL CI-CF-EL-S DATE:

43 - METL #12 PANCAKE STITCH 12"0.C. PERIMETER SEALANT SILL EXTRUSION WINDOW/LOUVER/DOOR/FRAMING / I tr======='ll' SUPPORT ~ llr-.---,--~ =--..J~I ~ ~ WIPER GASKET [7800VGR] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] '== CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT = 1 /4" HWH CLIP FASTENERS 14 GA. PANEL CLIP [4633GNC] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T SILL TYPE 3 CLIP TYPES CLIP TYPE BCLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9413A 1616PNC 1724PNC 1816PNC 2.5" 9413A 1624PNC 1732PNC 1824PNC 3" 9413A 1624PNC 1732PNC 1824PNC 4" 9412A 1632PNC 1740PNC 1832PNC SILL DETAIL CI-CF-ES-01 WI EXTRUSION DATE:

44 URETHANE END DAM INTERIOR HEAD TRIM WITH TABS BENT DOWN URETHANE EXTERIOR HEAD TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR TRIM WITH TABS BENT EXTERIOR JAMB TRIM BUTYL SEALANT FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP EXPOSED SEALANT (NOT BY PANEL PANEL MANUFACTURER) CD INTERIOR JAMB TRIM TRIM INSTALLATION SEQUENCE: CD INTERIOR JAMB TRIMS INTERIOR HEAD TRIM WITH TABS BENT DOWN TRIM WITH TABS BENT UP EXTERIOR JAMB EXTERIOR HEAD TRIM TRIM LAPS AT FRAMED OPENING CI-CF-T-01 DATE:

45 URETHANE END DAM URETHANE END DAM INTERIOR HEAD HEAD EXTRUSION 3/8" 0 WEEP JAMB EXTRUSION BUTYL SEALANT EXPOSED SEALANT (NOT BY PANEL PANEL EXTRUSION CD INTERIOR JAMB EXTRUSION EXTRUSION INSTALLATION SEQUENCE: d) INTERIOR JAMB EXTRUSIONS (g) INTERIOR HEAD EXTRUSION EXTRUSION EXTERIOR HEAD EXTRUSION EXTERIOR JAMB EXTRUSIONS EXTRUSION AT FRAMED OPENING CI-CF-E-01 DATE:

46 T METL 14 GA. PANEL CLIP [4633GNC]~ 1 /4" HWH CLIP FASTENERS ~ 1 #12 PANCAKE STITCH SCREW [12A] BASE TRIM ~ t [~~~ l 1/8" Ill RIVET ~ O.C. 0~ 11$ * [14] ~ ~ I~ rl ~ SUPPORT SR - /-= ~t=====---r;::;: 1 ~ f ~~~ ~~: CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT STACK JOINT TRIM fi CONTINUOUS ~ WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT FLASHING SEALANT TAPE I [71 OOBWH] [7405BWH] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] WORK POINT~ ELEV REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T STACK JOINT TYPE 3 CLIP TYPES CLIP TYPE BCLIP TRIM FASTENER FASTENER FASTENER 2" F PNC 1724PNC 1816PNC 2.5" F PNC 1732PNC 1824PNC 2.75" PNC 1732PNC 1824PNC 3" F PNC 1732PNC 1824PNC 4" F PNC 1740PNC 1832PNC STACK JOINT CI-CF-SJ-01 WI TRIM DATE:

47 (2) BEADS URETHANE SEALANT FIELD NOTCH HEM(S) AS REQUIRED NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - STACK JOINT CI-CF-EL -SJ DATE:

48 - METL 14 GA. PANEL CLIP [4633GNC] - ~ #12 PANCAKE 1/4" HWH CLIP FASTENERS STITCH FASTENER [SEECHART] ~~: [12A] WIPER GASKET : CONTINUOUS [ ] WITH MARRIAGE BEAD TO 7800GVR ~ : VERTICAL PANEL JOINT I ;"'-'{llm-~v SEALANT STACK JOINT EXTRUSION _... [71 OOBWH] 1 1 ~ URETHANE SEALANT ;; 'lrl LW......_. ~ -=- [HW540] 11 C')~ ~~~~~==============~---~W~O~R~K~P~O~IN~T~J.~ ~ dj :' >~ ELEV "17 FIELD DRILl_3/B" MIN. t / I:/ I WEEP HOLES _/ 24" O.C. WIPER GASKET [7800GVR] SPLICE BAR [9495A] ' ~ vr i!j~e~ SUPPORT CONTINUOUS i WITH MARRIAGE BEAD TO : VERTICAL PANEL JOINT SEALANT 1 I REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T STACK JOINT lype 3 CLIP 1YPE5 CLIP lype BCLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9455A 1616PNC 1724PNC 1816PNC 2.5" 9456A 1624PNC 1732PNC 1824PNC 3" 9458A 1624PNC 1732PNC 1824PNC 4" 9459A 1632PNC 1740PNC 1832PNC STACK JOINT CI-CF-ESJ-01 WI EXTRUSION DATE:

49 NOTE: THIS DETAIL IS FOR INFORMATIONAL PURPOSES ONLY. ALL ROOF COMPONENTS, PERIMETER FLASHING AND SEALANTS ARE NOT BY PANEL MANUFACTURER FLASHING SEALANT TAPE [7405BWH] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] 1/4" HWH CLIP FASTENERS 14 GA. PANEL CLIP [4633GNC] INTERIOR AIR/VAPOR SEAL CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71 OOBWH] SUPPORT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T TYPE Ill CLIP TYPEVCLIP TYPE B CLIP FASTENER FASTENER FASTENER 2" 1616PNC 1724PNC 1816PNC 2.5" 1624PNC 1732PNC 1824PNC 3" 1624PNC 1732PNC 1824PNC 2.75" 1624PNC 1732PNC 1824PNC 4" 1632PNC 1740PNC 1832PNC EAVE DETAIL- CI-CF-VE-01 CONVENTIONAL ROOF DATE:

50 - CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT ROOF MEMBRANE & PARAPET BLOCKING PARAPET CAP I i,::: '7'-~ I ~ ~ 1 /4" HWH CLIP FASTENERS : ~ 1 I ~ 1 "1--,-...-'{l a 1 I SUPPORT I I METAL CLEAT AND ) L I FORM OF ATTACHMENT / ~ lr- ~! ~ FLASHING SEALANT TAPE [7405BWH] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] 1 ~ 14 GA. PANEL CLIP ~ ~FE~ FASTENER = (NOT BY PANEL MANUFACTURER)... REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T TYPE 3 CLIP TYPE 5 CLIP TYPE B CLIP FASTENER FASTENER FASTENER 2" 1616PNC 1724PNC 1816PNC 2.5" 1624PNC 1732PNC 1824PNC 2.75" 1624PNC 1732PNC 1824PNC 3" 1624PNC 1732PNC 1824PNC 4" 1632PNC 1740PNC 1832PNC PARAPET(SUPPORTED) CI-CF-TP-01 W/ TRIM DATE:

51 - PARAPET EXTRUSION ~ ROOF MEMBRANE & PARAPET CAP ~ F:::!!!!!==:'::r;r:~.,.., CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71 OOBWH] PARAPET BLOCKING {NOT BY PANEL MANUFACTURER) rri!ft~,, _ ~w~-!fw-~r~ IJ!~~ -~~~-~-~~-~-=-=T_'-=_-; 1/4" HWH CLIP FASTENERS ~! [SEECHART] v: 1 VAJ: Iif'::\_5) SUPPORT ~=-~=t~ FASTENER (NOT BY PANEL = MANUFACTURER) 14 GA. PANEL CLIP / [4633GNC] 1. REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T TYPE 3 CLIP TYPE 5 CLIP TYPE B CLIP FASTENER FASTENER FASTENER 2" 1616PNC 1724PNC 1816PNC 2.5" 1624PNC 1732PNC 1824PNC 2.75" 1624PNC 1732PNC 1824PNC 3" 1624PNC 1732PNC 1824PNC 4" 1632PNC 1740PNC 1832PNC PARAPET(SUPPORTED) CI-CF-EP-02 WI EXTRUSION DATE:

52 2" BASE EXTRUSION [9405A] 2" BASE/SOFFIT EXTRUSION [9414A] 2" STACK JOINT EXTRUSION [9455A] 2" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9420A] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] -- II. 2" VERTICAL H JOINTlf EXTRUSION INTERIOR (FEMALE) [9450A] I I 2" VERTICAL H JOINT EXTRUSION ~t:!~?r (MALE) 1!!::-!!:::' =::::!!IHI!:::=:!-::!1' WIPER GASKET [?BOOVGR] EXTRUDED ALUMINUM SPLICE BAR [9495A] 2" OUTSIDE CORNER INTERIOR (FEMALE) [9430A] INSIDE CORNER INTERIOR (MALE) [9435A] 2" SILL EXTRUSION [9413A] OUTSIDE CORNER EXTERIOR (MALE) [9425A] 2" INSIDE CORNER EXTERIOR (FEMALE) [9440A] 2 11 EXTRUSIONS CI-CF-2-EXT DATE:

53 A Divioion of NCI Grou,. I no. 2.5" BASE EXTRUSION [9406A] 2.5" STACK JOINT EXTRUSION [9455A] 2.5" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9421A] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] WIPER GASKET [7800VGR] EXTRUDED ALUMINUM SPLICE BAR [9495A] 2.5" OUTSIDE CORNER INTERIOR (FEMALE) [9431A] OUTSIDE CORNER EXTERIOR (MALE) [9425A] EXTRUSIONS CI-CF-2.5-EXT DATE:

54 3" BASE EXTRUSION [9407A] 3" STACK JOINT EXTRUSION [9458A] 3" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9422A] WIPER GASKET [7800VGR] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] -- II, EXTRUDED ALUMINUM SPLICE BAR [9495A] 3" OUTSIDE CORNER INTERIOR (FEMALE) [9432A] OUTSIDE CORNER EXTERIOR (MALE) [9425A] 3 11 EXTRUSIONS CI-CF-3-EXT DATE:

55 4" BASE EXTRUSION [9404A] WI PER GASKET [7800VGR] EXTRUDED ALUMINUM SPLICE BAR [9495A] 4" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9423A] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] -= II, 4' STACK JOINT EXTRUSION [9459A] 4" OUTSIDE CORNER INTERIOR (FEMALE) [9433A] 4" SILL EXTRUSION [9412A] OUTSIDE CORNER EXTERIOR (MALE) [9429A] 4 11 EXTRUSIONS CI-CF-4-EXT DATE:

56 NEW PENETRANT (INSTALL THROUGH CUTOUT) PANEL CUTOUT (1/2' MINIMUM CLEARANCE AROUND PENETRANT) EXPANDABLE FOAM : ~. WALL SUPPORT NEW PENETRANT IN EXISTING WALL SEE DETAIL CI-CF-PEN-5 FOR FLASHING INFORMATION PIPE PENETRATION FIELD OF PANEL CI-CF-PEN-1 DATE:

57 PANEL CUTOUT (EXTEND AS A SLOT TO THE PANEL EDGE) EXISTING PENETRANT METL SLIDE PANEL TO FIT AROUND PENETRANT,.... WALL SUPPORT NEXT WALL PANEL EXISTING PENETRANT IN NEW WALL PANEL CUTOUT EXISTING PENETRANT EXPANDABLE FOAM WALL SUPPORT SEE DETAIL CI-CF-PEN-4 FOR SEALANT LOCATIONS SEE DETAIL CI-CF-PEN-5 FOR FLASHING INFORMATION PIPE PENETRATION NOTCHED PANEL CI-CF-PEN-2 DATE:

58 PANEL CUTOUT (1/2" MIN. CLEARANCE AROUND PENETRANT) NEW PENETRANT EXPANDABLE FOAM WALL SUPPORT PANEL JOINT NEW PENETRATION IN EXISTING WALL AT PANEL JOINTS SEE DETAIL CI-CF-PEN-4 FOR SEALANT LOCATIONS PIPE PENETRATION AT PANEL JOINT CI-CF-PEN-3 DATE:

59 EXTERIOR URETHANE JOINT SEALANT (TO TOP OF WALL) r EXTERIOR WEATHER SEAL (NEW PENETRANT, EXISTING WALL) COVER PLATE SEALANT LOCATION l/1 PANEL CUTOUT -...,.--. -:.. ~ :.. ) SEAL JOINT CAVITY AT TOP & BOTIOM ~OFCUTOUT INTERIOR AIR/VAPOR SEAL (NEW PENETRANT, EXISTING WALL) PIPE PENETRATION WEATHER SEALS AT JOINT CI-CF-PEN-4 DATE:

60 PENETRANT METL WALL PANEL BOTTOM COVER PLATE BOTTOM COVER PLATE INSTALLATION RIVET OR SCREW (TYP) WALL PANEL bl URETHANE SEALANT BOTTOM COVER PLATE TOP COVER PLATE INSTALLATION EXPOSED URETHANE SEALANT 3/8" (MIN) FILLET WALL PANEL COVER PLATE ASSEMBLY PENETRATION PERIMETER SEAL PIPE PENETRATION- FLASHING CI-CF-PEN-5 DATE:

61 STRUCTURAL METL WALL SUPPORT WALL PANEL PANEL CUTOUT (AT CENTER OF PANEL) STRUCTURAL WALL SUPPORT PANEL CUTOUT (AT PANEL JOINT) STRUCTURAL EXPANDABLE FOAM FILLER INSULATION WALL PANEL BEAM PENETRATION CI-CF-PEN-6 DATE:

62 RIVET OR SCREW (TYP) METL LEFT COVER PLATE RIGHT COVER PLATE COVER PLATE 2' Lap Area COVER PLATE LAYOUT WALL PANEL RIGHT COVER PLATE INSTALLATION STRUCTURAL COVER PLATE WALL PANEL LEFT COVER PLATE INSTALLATION STRUCTURAL WALL PANEL PENETRATION PERIMETER SEAL BEAM PENETRATION - FLASHING CI-CF-PEN-7 DATE:

900 SERIES WALL PANELS

900 SERIES WALL PANELS CI-DS-01-900 CI-PP-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-PJ-03-900 CI-BS-01-900 CI-BS-02-900 CI-BS-03-900 CI-BS-04-900 CI-BS-05-900 CI-OC-01-900 CI-OC-02-900 CI-IC-01-900 CI-FO-01-900 CI-FO-02-900 CI-FO-03-900

More information

400 SERIES VERTICAL INSTALLATION

400 SERIES VERTICAL INSTALLATION CI-DS-01-400V CI-PJ-01-400V CI-PJ-02-400V CI-PJ-03-400V CI-BS-01-400V CI-BS-02-400V CI-BS-03-400V CI-BS-04-400V CI-BS-05-400V CI-OC-01-400V CI-OC-02-400V CI-IC-01-400V CI-IC-02-400V CI-FO-01-400V CI-FO-02-400V

More information

DW HORIZONTAL INSTALLATION

DW HORIZONTAL INSTALLATION AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S

More information

KS42 MF SERIES - HORIZONTAL INSTALLATION

KS42 MF SERIES - HORIZONTAL INSTALLATION CI-DS-01-KSMF H CI-PJ-01-KSMF H CI-PJ-02-KSMF H CI-PJ-03-KSMF H CI-PJ-04-KSMF H CI-PJ-05-KSMF H CI-PJ-06-KSMF H CI-PJ-07-KSMF H CI-PJ-08-KSMF H CI-PJ-09-KSMF H CI-PJ-10-KSMF H CI-PJ-11-KSMF H CI-PJ-12-KSMF

More information

DW VERTICAL INSTALLATION

DW VERTICAL INSTALLATION AR-PJ-01-DW5V AR-PJ-02-DW5V AR-PJ-03-DW5V AR-PJ-04-DW5V AR-BS-01-DW5V AR-BS-02-DW5V AR-OC-01-DW5V AR-OC-02-DW5V AR-OC-03-DW5V AR-IC-01-DW5V AR-IC-02-DW5V AR-IC-03-DW5V AR-FO-01-DW5V AR-FO-02-DW5V AR-FO-03-DW5V

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV

More information

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET KPH-DS-01-MTLV KPH-PP-01-MTLV KPH-PP-02-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-FS-01-MTLV KPH-FS-02-MTLV KPH-FS-03-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV

More information

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. FRKPV-DS-01-MTLH FRKPV-PJ-01-MTLH FRKPV-PJ-02-MTLH FRKPV-PJ-03-MTLH FRKPV-FS-01-MTLH FRKPV-FS-02-MTLH FRKPV-BS-01-MTLH FRKPV-BS-02-MTLH FRKPV-BS-03-MTLH FRKPV-BS-04-MTLH FRKPV-OC-01-MTLH FRKPV-IC-01-MTLH

More information

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET KPV-DS-01-BRH KPV-PJ-01-BRH KPV-PJ-02-BRH KPV-PJ-03-BRH KPV-BS-01-BRH KPV-BS-02-BRH KPV-BS-03-BRH KPV-OC-01-BRH KPV-IC-01-BRH KPV-FO-01-BRH KPV-FO-02-BRH KPV-FO-03-BRH KPV-SJ-01-BRH KPV-PR-01-BRH KPV-LE-01-BRH

More information

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. KPV-DS-01-MTLH C & I DISCLAIMER KPV-PJ-01-MTLH EXPANDED PANEL JOINT KPV-PJ-02-MTLH ENGAGED PANEL JOINT KPV-PJ-03-MTLH INTERMEDIATE SUPPORT KPV-FS-01-MTLH MULTI-STORY FIRE STOPPING DETAIL KPV-FS-02-MTLH

More information

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR 900 SERIES PANEL CI-DS-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-EL-01-900 CI-EL-02-900 CI-EL-03-900 CI-EL-04-900 CI-EL-05-900 CI-EL-06-900 CI-EL-07-900 CI-EL-08-900 CI-RD-01-900 CI-RD-02-900 CI-RD-03-900 CI-EV-01-900

More information

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL Window assembly GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS DETAIL TITLE FILE NO. PAGE NO. INTRODUCTION..................................................................

More information

TABLE OF CONTENTS A-1

TABLE OF CONTENTS A-1 TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1...GENERAL INFORMATION C-1...EAVE DRIP DETAIL C-2...EAVE DRIP with GUTTER DETAIL C-3 & C-4...FIXED RIDGE

More information

REGAL. Installation Manual

REGAL. Installation Manual REGAL Installation Manual General Information The details shown on the following pages are suggestions or guidelines for installing the Regal system. The installation details shown here are proven methods

More information

SEAL PLATE SP4413 VERTICAL SP4414 1"[25] VERT. PANEL JTS. 1/2"[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM.

SEAL PLATE SP4413 VERTICAL SP4414 1[25] VERT. PANEL JTS. 1/2[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM. 3 COL 5 16GA. ANGLE SP4413 VERTICAL SEE SUPPORT DRAINGS 1 7/16 SEAL PLATE @ VERT. JNT 1/2 [13] Ă DETAILER NOTE OPTIONAL INSULATION HEN REQUIRED. OF SEAL PLATE PANEL MODULE 2.500 FROM SHELF OF TR. TO TOP

More information

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide Flushglaze 4500 For Framed Openings and Horizontal Panels Window System Installation Guide January 2017 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels

More information

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

40mm Thermoclick.  Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) http://www.sundancesupply.com 40mm Thermoclick Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) U-Profile 12' Lengths $39 Out System offers a complete set of extrusions and accessories

More information

TremLock T-138 INSTALLATION MANUAL T-138 www.tremcoroofing.com 3735 Green Road Beachwood, Ohio 44122 1.800.852.6013 50 Beth Nealson Drive Toronto, Ontario M4H 1M6 1.800.668.9879 7241 6/8/18 TABLE OF CONTENTS

More information

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit Horizontal battens between verticals at soffit 2 C.04 600 600 600 600 Cavity batten at 600 mm centres 1 C.03 Batten fixing points 1 C.04 1 C.07 1 C.12 1 C.13 1 C.14 Meter Box Window 1 C.08 1 C.09 800 800

More information

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24 O.C. ALL FASTENERS TO PENETRATE WOOD 3/4 MIN. AND METAL FRAMING 1/2 MIN. PLYWOOD SHEATHING DMI SOFFIT PANEL #10-13 GP PANCAKE HEAD (JC) - J CLOSURE (LC) - L CLOSURE #9-15 X 1 1/2" WOODZAC GP APPROVED MOISTURE BARRIER SOFFIT TO WALL PANEL WPRP-H-01-00 APPROVED MOISTURE BARRIER

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

Storefront Installation Guide

Storefront Installation Guide Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation

More information

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions 14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6

More information

BuildingEnvelope Oldcastle ( ) -

BuildingEnvelope Oldcastle ( ) - BuildingEnvelope 1-866-Oldcastle (653-2278) - www.obe.com RELIANCE -LT CURTAIN WALL 2" X 7-1/2" / POLYAMIDE PRESSURE PLATE / 1" GLAZING Elev-Reliance-LT-750-PolyPP H0042-Steel-Anchor H5021-ShrBlk-Anchors

More information

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS Reference Guide 0.1 GENERAL 0.1 Reference Guide 0.2 Index 0.3 Disclaimer & Limitations 0.4 General Notes

More information

GLOSSARY OF TERMS SECTION 8

GLOSSARY OF TERMS SECTION 8 GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the

More information

Steel Sound Enclosure

Steel Sound Enclosure Steel Sound Enclosure INSTALLATION MANUAL List of tools recommended for use during installation: vise grips c clamp ladder electric drill drill bits / taps as req d screw drivers hammer rubber mallet pipe

More information

Metl-Span CF-42 Santa Fe Wall Panels 24 Ga. Exterior / 26 ga. Interior Facings Allowable Connection Load 1,7,8,9,10 (psf) Two or More Equal Spans

Metl-Span CF-42 Santa Fe Wall Panels 24 Ga. Exterior / 26 ga. Interior Facings Allowable Connection Load 1,7,8,9,10 (psf) Two or More Equal Spans Metl-Span CF-42 Santa Fe Wall Panels 24 Ga. Exterior / 26 ga. Interior Facings Allowable Connection Load 1,7,8,9,10 (psf) Two or More Equal Spans Panel Type 2 Design Criteria 3,4,5,6 Support Span 5 ft

More information

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION TOOLS AND SUPPLIES 1 TOOLS CHECK LIST 1. laser level 2. hammer 3. pry bars 4. ladders 5. utility knife 6. screw gun 7. applicator foam gun 8. "j"

More information

INOVO 2-LITE SLIDING PATIO DOOR

INOVO 2-LITE SLIDING PATIO DOOR INOVO 2-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS IMPORTANT: READ THE INSTRUCTIONS AND FAMILIARIZE YOURSELF WITH THE DOOR PARTS AND PIECES BEFORE BEGINNING ASSEMBLY AND INSTALLATION.

More information

ThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST

ThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST ThermoSpan EPS DETAIL LIST 00 / 15 COVER SHEET 01 / 15 RIDGE DETAIL 02 / 15 HEAD FLASHING DETAIL 03 / 15 EAVES GUTTER DETAIL 04 / 15 INSULATED GUTTER 05 / 15 INSULATED BOX GUTTER 06 / 15 BARGE CAPPING

More information

WESTERN WAVE Panel. Vertical Installation and Technical Information

WESTERN WAVE Panel. Vertical Installation and Technical Information WESTERN WAVE Panel Vertical Installation and Technical Information Western States Western Wave Wall and Soffit Panels (Vertical) Installation, Flashings & Shop Drawing Detail Guide Section Notes to Designer

More information

calculated with factor of safety of 2.5 for bending stress, 3.0 for shear stresses and deflection limitation of L/180.

calculated with factor of safety of 2.5 for bending stress, 3.0 for shear stresses and deflection limitation of L/180. Metl-Span CF-42 Light Mesa Wall Panels 26 Ga. Exterior / 26 Ga. Interior Facings Allowable Connection Load 1,7,8,9,10 (psf) for Two or More Equal Spans Panel Type 2 Design Criteria 3,4,5,6 Support Span

More information

WESTERN WAVE Panel. Horizontal Installation and Technical Information

WESTERN WAVE Panel. Horizontal Installation and Technical Information WESTERN WAVE Panel Horizontal Installation and Technical Information Western States Western Wave Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page

More information

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection... Table of Contents Section Page Notes to Designer/User... 2-3 Map of Typical Roof Conditions... 4 Fastener Placement... 5 Fastener Selection... 6 Ridge/Hip Flashing... 7 Valley Flashing... 8 Eave Flashings...

More information

Construction details: Master-C type profiles and joints:

Construction details: Master-C type profiles and joints: Construction details: Master-C type profiles and joints: Master-C 3g 32 mm. (1 1/4 ) 1000 mm. (39 3/8 ) outer face inner face 10.5 fixing details: sealing washers shall be installed through a 2-3/8 x 1-9/16

More information

TABLE OF CONTENTS A. PBR

TABLE OF CONTENTS A. PBR TABLE OF CONTENTS A. PBR Panel 1. PBR Panel Architect/Engineer Information....................................... 2 2. PBR Panel UL 90 Requirements............................................... 3 3. PBR

More information

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement 1 Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement The following instructions are a supplement

More information

Santa Fe Cover INSTALLATION GUIDE. Alumawood TM Newport with MAXX Panel TM Installation Guide

Santa Fe Cover INSTALLATION GUIDE. Alumawood TM Newport with MAXX Panel TM Installation Guide Alumawood TM Newport with MAXX Panel TM Installation Guide Santa Fe Cover INSTALLATION GUIDE Whatever the weather, you can enjoy the sophisticated charm of a lattice cover. The Santa Whatever the weather,

More information

PROVEN DEPENDABLE SUSTAINABLE

PROVEN DEPENDABLE SUSTAINABLE B/SOFFIT FP CLIP 24" O.C. MAX SECTION "A-A" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. A B/SOFFIT A (JC) - J CLOSURE DMI WALL PANEL PLYWOOD SHEATHING SOFFIT TO WALL PANEL FR10-V-01-00 B/SOFFIT

More information

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN MINNEAPOLIS, MN 2-0- 2-- General Notes Abbreviations Deviations from Architectural Specifications Deviations from Architectural Drawings ALUM. = ALUMINUM B.O. = BY OTHERS CONT. = CONTINUOUS. = CLEARANCE

More information

Table of Contents Light Gauge Metal Roof & Wall Panels

Table of Contents Light Gauge Metal Roof & Wall Panels Table of Contents Light Gauge Metal Roof & Wall Panels Installation Guide for Delta Rib, Nor-Clad, Strata Rib & 2-1/2 Corrugated Introduction Important Notice Notes: April 2008 Minimum Recommended Tools

More information

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS IMPORTANT: READ THE INSTRUCTIONS AND FAMILIARIZE YOURSELF WITH THE DOOR PARTS AND PIECES BEFORE BEGINNING ASSEMBLY AND INSTALLATION.

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 08/31/2018 Installation Guideline Disclaimer This document contains general installation

More information

DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988

DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988 FP CLIP 24" O.C. MAX B/SOFFIT 5 1/2" SECTION "A-A" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. A B/SOFFIT A (JC) - J CLOSURE DMI WALL PANEL PLYWOOD SHEATHING SOFFIT TO WALL PANEL FR15-V-01-00

More information

Kocked Down with Ends Assembled

Kocked Down with Ends Assembled Installation Instructions for Quarter Round (QR) Kocked Down with Ends Assembled Note: Prior to starting Installation, check unit/parts for damage. Please read entire Installation Instructions & review

More information

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS 2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed

More information

4500 Series. Fabrication and Installation Instructions

4500 Series. Fabrication and Installation Instructions 4500 Series Fabrication and Installation Instructions E4500 Series July, 2017 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 5 ACCESSORIES... 7 OVERVIEW... 8 FRAME FABRICATION...

More information

CROSSBAR RAFTER ISOMETRIC

CROSSBAR RAFTER ISOMETRIC Super Sky Products' typical glazing system consists of glass panels or "lites" which are attached to the main framing members using extruded aluminum "retainers" or "pressure plates". These retainers are

More information

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS ULTRA WINDOW & DOOR S AND RECEIVERS INSTALLATION INSTRUCTIONS! CAUTION: *REMEMBER SAFETY FIRST* Proper Eye and! Hearing Protection must always be worn during installation of all window and door products.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation SL-450TB (2" x 4-1/2" with 1" Glazing) & SL-600TB (2" x 6" with 1" Glazing) IMPORTANT: Read all instructions before beginning installation.

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions 14000 Series Revision December 01, 2009 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 4 ACCESSORIES... 7 OVERVIEW...

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 9/29/2017 Installation Guideline Disclaimer This document contains general installation

More information

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504 ATTACH TO STRUC- TURE ABOVE 1/8"Ø BOLT W/ LOCKING NUT #12 WIRE TIE IN PLANE EACH TEE ANGLED 45 FROM HORIZ ATTACH 2" FROM INTERSECTION COMPRESSION POST LOCATE WITHIN 2" OF TEE INTERSECTION SIZE STRUTS FOR

More information

Dear Contractor, I am glad that you are interested in our window rebate program.

Dear Contractor, I am glad that you are interested in our window rebate program. Dear Contractor, I am glad that you are interested in our window rebate program. I have included three documents with this letter. One is our form to indicate your intention to participate in the program.

More information

Dura-Lock Roof System

Dura-Lock Roof System DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.

More information

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass Deep pocket allows for direct anchor attachment to substrate without flat filler plate. 1/4 Ø perimeter anchor holes allows for direct anchor attachment

More information

Tuff-Rib Install Guide

Tuff-Rib Install Guide Install Guide bestbuymetalroof.com Page 2 of 27 Page 3 of 27 1. Page 4 2. a. Installation Guide b. Panel Squaring Pages 5, 6 Pages 7, 8 3. Pages 9, 10 4. a. Fascia (optional) b. Eave / 1.5x3.5 Angle c.

More information

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11 INSTALLATION MANUAL CONTENTS Important Notes... 2-4 Weather Protective Barriers... 2 Storage and Transportation... 2 Tools and Equipment... 2 Fastener Choices... 3 Wall Preparation... 3,4 Flashing... 4

More information

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR www.quakerwindows.comv www.quakercommercialwindows.com PO Box 128 504 Highway 63 South Freeburg, MO 65035 800-347-0438 573-469-4151 (fax) Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

More information

HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY

HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY TABLE OF CONTENTS DETAIL TITLE PAGE

More information

Pocket Door Installation Instructions

Pocket Door Installation Instructions Installation Instructions Before getting started: Read instructions thoroughly. Be sure that you have the necessary tools and materials before starting the installation. Consult your local building code

More information

Revision Date: April 01, Paramount Enclosure

Revision Date: April 01, Paramount Enclosure Paramount Enclosure www.urbanindustries.com 15 Urban Industries, Inc. 2008 Tools The following tools are recommended for the installation of the Paramount Aluminum Enclosure and roof. 1 2 Level 1 4 Level

More information

SECTION SHEET METAL FLASHING AND TRIM

SECTION SHEET METAL FLASHING AND TRIM SECTION 07620 PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Formed roof drainage sheet metal fabrications. 2. Formed low-slope roof sheet metal fabrications. 1.2 SUBMITTALS A. Shop Drawings: Show

More information

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.

More information

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA TRS 9 35MM 78MM 150MM 78MM THICKNESS END SPAN INTERNAL SPAN MINIMUM PITCH 0.55MM 2.30M 3.20M 3 DESCRIPTION TRS 9 profile is designed for commercial and industrial roofing. The profile is suitable for low

More information

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE:

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE: BuildingEnvelope R FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE: THE INSTALLATION DETAILS FOUND IN THIS PACKAGE ARE GENERIC AND ARE FOR REPRESENTATION ONLY WITH THE INTENT OF GIVING THE INSTALLATION

More information

Thermally Broken Framing and Door Installation

Thermally Broken Framing and Door Installation INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL The ProTEC panels are manufactured with grooves on all four sides to accept the steel components. This grooving applies to the regular panel whose

More information

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

CARRIER OVERHANG 1'-0 MAX PANEL LENGTH 3'-0 MIN - 16'-0 MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise) DETAIL 5 32 5 " 27 32 " 6" OPTIONAL FLAT RECESSED CLOSURE 1 1 4 " 17 32 " 1 25 32 " OPTIONAL BUTTERFLY CLOSURE CARRIER OVERHANG 1'-0" MAX CARRIER SPAN 4'-0" 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS A CSW Industrials Company FR and FRE Roof Expansion Joint Covers IMPORTANT The following instructions are very important. Read them carefully, and be sure you understand them

More information

Guardian ¾ Hip Ridge Skylight Installation Manual

Guardian ¾ Hip Ridge Skylight Installation Manual 2 ¾ Hip Ridge Skylight Installation Manual This instructional manual provides General Installation Instruction. Installers should refer to the "as-built" shop drawings for specific guidance as it relates

More information

Series Advanced and alternate. Installation Instructions

Series Advanced and alternate. Installation Instructions Series 5500 Advanced and alternate Installation Instructions Part NO. Y557 February 2013 TABLE OF CONTENTS SECTION S-5500 ADVANCED INSTALLATION INSTUCTIONS PAGE I. General Notes and Guidelines...... 3-4

More information

YES 600 Thermal Clip Storefront System Installation Manual

YES 600 Thermal Clip Storefront System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................

More information

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

Series Sloped glazed Curtain wall. Installation Instructions

Series Sloped glazed Curtain wall. Installation Instructions Series 5600 Sloped glazed Curtain wall Installation Instructions Part NO. Y308 February 2013 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines. 3-4 II. Gutter and Mullion Assembly.. 5 III. End

More information

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME

More information

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions PO Box 480 Ph: 417-235-7821 Monett, MO 65708 Fax: 417-737-7140 Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions These installation instructions are recommendations

More information

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24 C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4 ROOF PANEL GABLE FLASHING FASTENER @ 24" C/C MAX. ROOF PURLIN BUTYL SEALANT TAPE FLASH AB-1, AB-2, AB-3, OR AB-4 FASTENER @ EVERY MAJOR RIB OR 12" C/C MAX. F-J TRIM FABRAL ALUMINUM SOFFIT FASTENER 24"

More information

FlexLoc. Technical/Installation Information

FlexLoc. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE FLEXLOC PANELS. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation

More information

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner. Steel Reinforced Joining (Horizontal/Vertical) for Andersen 400 Series Woodwright & Tilt-Wash Double-Hung, Picture, and Transom Windows and 400 Series Double-Hung Half Circle and Flexiframe Specialty Windows

More information

eco-shake INSTALLATION INSTRUCTION

eco-shake INSTALLATION INSTRUCTION 1 eco-shake INSTALLATION INSTRUCTION NOTE: Shuffling the eco-shakes during installation may be necessary to obtain a uniform color throughout the roof. Due to the natural wood content in the ecoshakes,

More information

METALWORKS Linear (Interior & Exterior Applications)

METALWORKS Linear (Interior & Exterior Applications) CEILING&WALL SYSTEMS Between us, ideas become reality METALWORKS Linear (Interior & Exterior Applications) Assembly and Installation Instructions 1. GENERAL 1.1 Product Description MetalWorks Linear is

More information

Non-Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows

Non-Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly,

More information

Illustration Part Description Base List Weight/ Ft./ Box Number Price/S.L. S.L. S.L. Qty.

Illustration Part Description Base List Weight/ Ft./ Box Number Price/S.L. S.L. S.L. Qty. Prices DO NOT include glazing gaskets or weathering. See Accessories sheet. Exterior Glazed Back Members for 1" Glass Illustration Part Description Base List Weight/ Ft./ Box Price/S.L. S.L. S.L. Qty.

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! OCTOBER Phone: OLDCASTLE ( ) Web Address:

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! OCTOBER Phone: OLDCASTLE ( ) Web Address: Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF CONTENTS General Information............................. Page 2 4 Outside Glaze Non Thermal...............................Page

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions Revision May 2013 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...5 ACCESSORIES...8 OVERVIEW...10 FRAME FABRICATION...15

More information

GIRTS ON BACK OF BUILDING

GIRTS ON BACK OF BUILDING GIRTS ON BACK OF BUILDING ALL GIRTS ARE 1 1/2 SQUARE TUBE. GIRT LENGTHS FOR 12, 20, 24, AND 30 WIDE BUILDINGS: ON 12 WIDE BUILDINGS GIRTS ARE 67 3/4 LONG ON 20 WIDE BUILDINGS GIRTS ARE 56 3/4 LONG ON 24

More information

TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION (FASTENER PATTERNS)

TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION (FASTENER PATTERNS) FW SERIES TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION (FASTENER PATTERNS) DETAILS C-1...SIMPLE BASE DETAIL with 1 1/2"

More information

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG 2008 Pella Corporation Part Number: 80ED0101 INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG Instrucciones en español

More information

Guardian ¾ Polygon Skylight Installation Manual

Guardian ¾ Polygon Skylight Installation Manual Guardian 275 2 ¾ Polygon Skylight Installation Manual This instructional manual provides General Installation Instruction. Installers should refer to the "as-built" shop drawings for specific guidance

More information

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE) THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE) fig.3 Casement, Awning, Fixed Casement, Direct-Set, Double-Hung, Single-Hung & Horizontal Slider Windows Materials

More information

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM S Y S T E M D E T A I L S FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM PAGE TITLE PAGE Table of Contents Fundermax Max Exterior Product Information Design and Installation Information

More information

YES 45 XT High Performance Thermal Storefront System

YES 45 XT High Performance Thermal Storefront System Dual Thermal Barrier ThermaBond Plus Pour & Debridge Technology Installation Manual 2015 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page

More information

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws. Sheet Steel Facts Fastener Guide for Sheet Steel Building Products August, 2003 Fastener Materials Fasteners are manufactured from several materials and coatings. For the purpose of this fact sheet, the

More information

Non-Reinforced Joining Guide (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products

Non-Reinforced Joining Guide (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products Non-Reinforced Joining Guide Congratulations! You have just purchased one of the many fine

More information

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside. Effective Date: 10/1/2017 Tools Needed Kit Contents Hardware Kit Safety Glasses Cordless drill Phillips screw bit Two-step drill bit (3/8-1/8 ) utility knife Interior Mullion Exterior Mullion Cover clamps

More information

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools... INS-88.300-0A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE 1. Verify Curb Installation... 2 2. Required Installation Tools... 2 3. Unpacking the KSR... 3 4. Attach KSR Bottom Rail to Curb... 5 5. Attach

More information

Installation Recommendations for Finless Frame Doors

Installation Recommendations for Finless Frame Doors Installation Recommendations for Finless Frame Doors These installation recommendations are made available by MI Windows and Doors, LLC (MI) to assist with the integration of finless or flange sliding

More information