1 Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY!

2 TABLE OF CONTENTS General Information Page 2 4 Outside Glaze Non Thermal Page 11 Inside Glaze Screw Spline Non Thermal Page Stack System Outside Glaze Page FG-3000 Parts List Page Infill Thickness Options Chart Page 28 1

3 F L U S H G L A Z E S E R I E S I N S T A L L A T I O N M A N U A L GENERAL INFORMATION The Oldcastle BuildingEnvelope (2 x 4 1/2) system represents the latest in product development technology complemented by dealer on-the-job input and experience. Proper use of these systems will assure optimum results in erection and long term performance Oldcastle BuildingEnvelope does not control the application nor selection of its product configurations, sealant or glazing materials and assumes no responsibility thereof. It is the responsibility of the owner, architect and installer to make these selections in strict compliance with applicable laws and building codes. PROTECTION AND STORAGE: Handle the material carefully. Do not drop from the truck. Stack with adequate separation so that the material will not rub together. Store material off the ground. Protect against the elements and other construction hazards by using a well ventilated covering. Remove material from package if it is wet or is located in a damp area. CHECK MATERIAL: Check all material upon arrival for quality and to assure against shipping damage. Any visible damage must be noted on the freight bill at the time of receipt. If a claim is required, then the receiving party must process a claim with the freight company. Completely check construction which will receive your materials against contract documents. Notify the general contractor by letter of any discrepancies before proceeding with the work. Failure to do so constitutes acceptance of work by other trades. Check shop drawings and installation instructions to become familiar with the project. The shop drawings take precedence and include specific details for the project. The installation instructions are of a general nature and cover the most common conditions. Due to varying job conditions, all sealants used should be approved by the sealant manufacture, to insure they will function for conditions shown on instructions and shop drawings. They must be compatible with all surfaces in which adhesion is required, including other sealant surfaces. Use primers where directed by manufacturer of sealants. Be sure to properly store sealants at recommended temperatures and check sealant for remainder of shelf life before using. FIELD CONDITIONS: Do not install wall if there is a walk way with a downslope towards an entrance or a storefront All materials to be installed plumb, level, and true. Aluminum to be placed in direct contact with the masonry or incompatible materials, should be isolated with a heavy coat of zinc-chromate or bituminous paint. After sealant is set and a representative amount of the wall has been glazed (20 square feet or more), run a water hose to check installation. On large jobs, hose test should be repeated during glazing operation. Test should be conducted in accordance with AAMA 01.2 specifications. Coordinate protection of installed materials with general contractors and other trades. 2

4 GENERAL INFORMATION CONT. CLEANING MATERIALS: Cement, plaster, terrazzo, alkaline and acid based materials used to clean masonry are very harmful to finishes and should be removed with water and a mild soap immediately or permanent staining will occur. A spot test is recommended before any cleaning agent is used. EXPANSION JOINTS: Expansion joints and perimeter seals shown in these instructions and in the shop drawings are shown at normal size. Actual dimensions may vary due to perimeter conditions and/or differences in metal temperature between the time of fabrication and time of installation. For example, a 12 foot unrestrained length of aluminum extrusion can expand or contract 3/32 of an inch over a 0 F change. Any movement potential should be accounted for at the time of the installation. THERMAL IMPROVEMENT SUGGESTIONS: To maintain or improve your wall installation, the following items should be considered: A. Blinds or drapes prevent warm air from washing the window. B. Warm air ventilators too far from the window will not adequately wash the window with air to prevent condensation. C. In extreme conditions, the fan of the heating system should not cycle on and off but should run continuously. D. Some heating systems have a water injection feature that can raise humidity levels. The higher the humidity level the more likely condensation or frost will form. Raising the temperature and reducing the humidity will usually solve the problem. E. On rare occasions, an extremely cold storm may cause frost to appear on the glass or framing. A space heater and electric fan blowing along the plane of the window wall can reduce or eliminate this temporary condition. 3

5 GENERAL INFORMATION CONT. TO DERIVE THE GREATEST BENEFIT FROM YOUR STOREFRONT INSTALLATION, WE RECOMMEND YOU REVIEW THE FOLLOWING. NOT RECOMMENDED PREFERRED SHIM & AIR SPACE. MIN. 1/4" THICK. X NOT ENOUGH METAL EXPOSED TO INTERIOR AT X. 4

6 OUTSIDE GLAZE SCREW SPLINE FRAME ASSEMBLY FG-32 FS-8 (TYP.) PART #: 223 (TYP. ) 2-11/16" 29/32" (TYP) 1-3/4" SCHNEE-MOORHEAD SM-601 1/8"X1/2" TACKY TAPE. PART # 4666 (OR EQUAL) NOTE: KEEP TAPE AWAY FROM SCREW SPLINES. NOTE: USE RAZOR KNIFE TO TRIM EXCESS SEALANT TAPE. DO NOT PULL TAPE TO TRIM. "F" (.27 DIA) DRILL THRU TYP. FG-33 TOP 0F HORIZONTAL 1/4" 1-3/4" FG-3142 SEALANT EXTERIOR ONLY 1-3/4" FG-30 FG /4" FOR FASTER, MORE ACCURATE HOLE FABRICATION, WE RECOMMEND THE EZ PUNCH FABRICATION TOOL. DJ- DRILL FIXTURE PART # 462 IS ALSO AVAILABLE TO AID FABRICATION FOR SCREW SPLINE FRAME ASSEMBLY.

7 OUTSIDE GLAZE SHEAR BLOCK FRAME ASSEMBLY 2-11/16" 29/32" 9/16" SCHNEE-MOORHEAD SM-601 1/8"X1/2" TACKY TAPE. PART # 4666 (OR EQUAL) NOTE: KEEP TAPE AWAY FROM SCREW SPLINES. NOTE: USE RAZOR KNIFE TO TRIM EXCESS SEALANT TAPE. DO NOT PULL TAPE TO TRIM. #11 TAP HOLE TYP. *AC-8-1 PART #: 633 TYP. #11 CLEAR HOLE TOP 0F HORIZONTAL 11/32" FG /4" TYP. 1-1/4" 7/16" *AC PART #: 629 FS-7 FS-6.20 DIA. TYP. FOR ROLL PIN ROLL PIN 7/16" FG /4" *AC PART #: 629 FG-37 1/4" *PACKAGE INCLUDES SCREWS AND ROLL PIN 29/32" TYP. 11/32" ROLL PIN TYP. #2 TAP HOLE DJ-6 DRILL FIXTURE PART # 463 IS ALSO AVAILABLE TO AID FABRICATION FOR SCREW SPLINE FRAME ASSEMBLY. FS-6 FG

8 F L U S H G L A Z E S E R I E S I N S T A L L A T I O N M A N U A L OUTSIDE GLAZE SILL FLASHING INSTALLATION SEALANT FG-2000-FP-4 END DAM FG-2169 SUB SILL FLASHING ANCHORS MUST BE CAP SEALED FG-2000-FP-7 SPLICE SEAL WITH A NON-SKINNING, NON-HARDENING SEALANT. FILL BREAK IN FLASHING AND SEAL UNDER SPLICE SHIM UNDER SILL FLASHING 1/4" NOM. Seal sub-sill joints up vertical leg of the flashing marry into perimeter seal DETAIL "A" 1/4" NOM. FG-3413 NOTE: SILL FLASHING SHOULD BE LEVEL AND MAKE SURE IT IS NOT TILTED TOWARD THE INTERIOR. 7

9 OUTSIDE GLAZE FRAME INSTALLATION FG-1122 X 4" LONG (PART SOLD IN STOCK LENGTHS.) CLEAR HOLE (SIZE DETERMIMED BY ANCHOR.) 1. ASSEMBLY WITHOUT FLASHING IS NOT RECOMMENDED. 2. DO NOT ANCHOR WALL THRU VERTICAL LEG OF FLASHING. FG-2188 PVC PROFILE USED TO IMPROVE INSTALLATION OF BACKER ROD AND PERIMETER SEALANT. (OPTIONAL) SEALANT ACCESS HOLE AT ALL ANCHOR LOCATIONS. (SIZE DETERMINED BY ANCHOR.) FG-2000-FP-3 PART #: 7944 DRILL CLEAR HOLE IN FLASHING THOUGH ANCHOR CLIP. THEN INJECT SEALANT INTO HOLE IN FLASHING AND UNDER ANCHOR CLIP. ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS. SILL ANCHOR FG-2000-FP-3 AND HEAD ANCHOR FG-2122 SHOULD BE LOCATED SO THAT THE ANCHOR IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION. 8

10 OUTSIDE GLAZE SILL FLASHING INSTALLATION AND PERIMETER SEAL E E E FG " LONG (PARTS SOLD IN STOCK LENGTHS.) APPLY SEALANT ALONG LENGTH OF SUB SILL AT AREAS A & B. LAY FLASHING ON SLAB AND SHIM ONLY AT LOW AREAS. RESEAL AT SHIM AREAS. SPACE BETWEEN SILL AND FLASHING (C) TO BE CONTINUOUSLY SEALED EXCEPT FOR 1/2"-3/4" SPACE UNDER VERTICAL MULLIONS FOR WEEPAGE. PRIOR TO INSTALLING FRAME, APPLY SEALANT CONTINUOUSLY ALONG SILL FLASHING (D). THIS WILL PROVIDE CONTINUOUS SEAL BETWEEN SILL AND SILL FLASHING. THE QUALITY OF THE INSIDE AND OUTSIDE PERIMETER SEALS (C AND E) MAY BE IMPROVED BY USING FG-2188 RIGID PVC FILLER. THE PART MAY BE USED IN FULL LENGTHS OR CUT INTO PIECES. ITS PURPOSE IS TO PROVIDE SUPPORT FOR THE BACKER ROD REGARDLESS OF JOINT OR SIZE. PERIMETED SEAL (F) IS FOR COSMETIC PURPOSES AND IS OPTIONAL. E NOTE: 1/2"- 3/4" WEEP HOLE REQUIRED IN SEALANT AT FLASHING (C)AT CENTER LINE OF MULLION. D C F FG-2000-FP-3 PART #: 7944 A B 9

11 OUTSIDE GLAZE SEALANT PROCEDURE FOR DOOR FRAME AT FLASHING FG-214 FG-31 FG-316 RUN SEALANT ONE INCH ABOVE FLASHING. FLASHING IS BED IN SEALANT AT DOOR JAMB. LEAVE FRONT OF DOOR JAMB CLEAR OF SEALANT FOR DRAINAGE PURPOSES. *USE SHEAR BLOCKS AS SHOWN ON PAGE 6 TO SECURE TO TUBULAR FRAME. DOOR FRAME IS ANCHORED BY FASTENERS THROUGH THRESHOLD AND THROUGH DOOR FRAME HEADER. DO NOT FABRICATE 2 PIECE DOOR FRAMES WITH POUR & DEBRIDGE PROFILES.

12 OUTSIDE GLAZE GLAZING PROCEDURE FG-1133 PART #: 364 VERTICAL GASKETS RUN THRU. NOTE: FIRST, WET BOTTOM OF SETTING BLOCKS WITH SOAPY WATER. ONCE GLASS IS SET, PUSH AGAINST GASKET AT SETTING BLOCK AREA. FAILURE TO DO SO MAY CAUSE DIAGONAL CRACKS TOWARDS SETTING BLOCKS DUE TO GLASS BENDING WHILE INSTALLING GASKET(S) IN CORNERS. FG-3144 FG-3146 PART #: 6471 GLAZING INSTALLATION INSTRUCTIONS GLASS SIZE 7/8" OVER DAY LIGHT OPENING SETTING BLOCK SET AT 1/4 POINT OR 1/8 POINT OF HORIZONTAL LENGTH DEPENDING ON LITE SIZE. WATER DIVERTERS GLAZE FROM BOTTOM TO TOP. INSTALL WATER DIVERTERS IN HORIZONTAL ABOVE, AFTER LITE BELOW IS IN POSITION. GLAZING GASKET GASKET MAY BE INSTALLED ON ONE OR BOTH SIDES SIMULTANEOUSLY. PROVIDE 3/8" ADDITIONAL GASKET FOR EACH FOOT OF DAYLIGHT OPENING TO PROVIDE ADEQUATE COMPRESSION FOR THE GLAZING INFILL. NOTE: CLEAN GASKET WITH ISOPROPYL ALCOHOL PRIOR TO SEALING CORNERS FG-00-FP-2 PART #: 6887 SET IN PLACE WITH SEALANT. MITER HORIZONTAL GASKET TO FIT VERTICAL GASKET.

13 INSIDE GLAZE SCREW SPLINE FRAME ASSEMBLY Most of the extrusions in this system are the same, only the sill and its anchors are different. Note that the tapes used for sealing the horizontals to mullions are located in a different manner. The sill is designed so that sill anchors may be cap sealed before the frame is installed. The frame is installed over the the sill with twist-in anchors. This prevents any additional screws from penetrating the sill and causing leaks under the sill. Multiple units require the use of split mullions. A minimum of 7/16" clearance between the jamb and sill end dam must be provided. This will allow a minimum of 3/8" clearance to move first unit sideways so the second unit with the same clearance will clear the interlocking legs of the expansion mull. Adjust frame locations before running perimeter seals. OBE recommends using FG-2188 vinyl filler to improve the perimeter seal. 3/8" MIN. CLEARANCE /16" CLEARANCE MIN. CLEARANCE 7/16" 1/8" SPACE OBE does not recommend the shear block or stack method of assembly for inside glazing. 12

14 INSIDE GLAZE SCREW SPLINE FRAME ASSEMBLY FG-32 FS-8 (TYP.) PART#: 223 (TYP.) 2-11/16" 29/32" (TYP) 1-3/4" "F" (.27 DIA) DRILL THRU TYP. 1/4" SCHNEE-MOORHEAD SM-601 1/8"X1/2" TACKY TAPE PART # 4666 (OR EQUAL) NOTE: KEEP TAPE AWAY FROM SCREW SPLINES. FG-3161 TOP 0F HORIZONTAL 1/4" 1-3/4" FG-3142 SEALANT EXTERIOR ONLY FG /4" FG-33 NOTE: USE RAZOR KNIFE TO TRIM EXCESS SEALANT TAPE. DO NOT PULL TAPE TO TRIM. FOR FASTER, MORE ACCURATE HOLE FABRICATION, WE RECOMMEND THE EZ PUNCH FABRICATION TOOL. DJ- DRILL FIXTURE PART # 462 IS ALSO AVAILABLE TO AID FABRICATION FOR SCREW SPLINE FRAME ASSEMBLY. 13

15 INSIDE GLAZE SILL FLASHING INSTALLATION SEALANT FG-3000-FP-4 PART #: 7947 FG ANCHORS DESIGNED TO TWIST IN. 2. SPACE ANCHORS MAX. 4" FROM EACH SIDE OF MULLION. 3. BENT LEG ALWAYS TO EXTERIOR. 4. NOTE: STAKE ANCHORS TO PREVENT HORIZONTAL MOVEMENT. ANCHORS MUST FACE EXTERIOR AS SHOWN. INTERIOR FG-3000-FP-3 PART #: 7948 FLASHING ANCHORS MUST BE CAP SEALED. A SHIM UNDER FLASHING IS THE PREFERRED METHOD FOR BEST THERMAL RESULTS. FLASHING SPLICE FG-3000-FP-11 PART #: 7979 NOTE: SILL FLASHING SHOULD BE LEVEL AND MAKE SURE IT IS NOT TILTED TOWARD THE INTERIOR. 1/4" NOM. SEAL WITH A NON-SKINNING, NON-HARDENING SEALANT. FILL BREAK IN FLASHING AND UNDER SPLICE. 14

16 INSIDE GLAZE FRAME INSTALLATION FG-2122 X 4" LONG (PART SOLD IN STOCK LENGTHS.) CLEAR HOLE (SIZE DETERMIMED BY ANCHOR.) FG-2188 PVC PROFILE USED TO IMPROVE INSTALLATION OF BACKER ROD AND PERIMETER SEALANT. (OPTIONAL) FG-3217 FG-3000-FP-3 PART #: 7948 ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS. SILL ANCHOR FG-3000-FP-3 AND HEAD ANCHOR FG-2122 SHOULD BE LOCATED SO THAT THE ANCHOR SCREW IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION. 1

17 INSIDE GLAZE, NON THERMAL SILL FLASHING INSTALLATION AND PERIMETER SEAL C C C FG-32 APPLY SEALANT ALONG LENGTH OF SUB SILL AT AREA A. PRIOR TO INSTALLING FRAME, APPLY SEALANT CONTINUOUSLY ALONG SILL FLASHING (B). THIS WILL PROVIDE CONTINUOUS SEAL BETWEEN SILL AND SILL FLASHING. FG " LONG (PARTS SOLD IN STOCK LENGTHS.) THE QUALITY OF THE INSIDE AND OUTSIDE PERIMETER SEALS (C ) MAY BE IMPROVED BY USING FG-2188 RIGID PVC FILLER. THE PART MAY BE USED IN FULL LENGTHS OR CUT INTO PIECES. ITS PURPOSE IS TO PROVIDE SUPPORT FOR THE BACKER ROD REGARDLESS OF JOINT OR SIZE. PERIMETED SEAL (D) IS FOR COSMETIC PURPOSES AND IS OPTIONAL. C THIS LEG MUST BE TO EXTERIOR. B NOTE: 1/4" WEEP HOLE REQUIRED IN FLASHING (E) AT MID-LITE. E B D A FG-3000-FP-3 PART #:

18 INSIDE GLAZE GLAZING PROCEDURE FG-1133 PART #: 364 VERTICAL GASKETS RUN THRU. NOTE: FIRST, WET BOTTOM OF SETTING BLOCKS WITH SOAPY WATER. ONCE GLASS IS SET, PUSH AGAINST GASKET AT SETTING BLOCK AREA. FAILURE TO DO SO MAY CAUSE DIAGONAL CRACKS TOWARDS SETTING BLOCKS DUE TO GLASS BENDING WHILE INSTALLING GASKET(S) IN CORNERS. HP-17 PART #: 267 FG-00-FP-2 PART #: 6887 SET IN PLACE WITH SEALANT. GLAZING INSTALLATION INSTRUCTIONS GLASS SIZE 7/8" OVER DAY LIGHT OPENING SETTING BLOCK SET AT 1/4 POINT OR 1/8 POINT OF HORIZONTAL LENGTH DEPENDING ON LITE SIZE. WATER DIVERTERS GLAZE FROM BOTTOM TO TOP. INSTALL WATER DIVERTERS IN HORIZONTAL ABOVE, AFTER LITE BELOW IS IN POSITION. GLAZING GASKET GASKET MAY BE INSTALLED ON ONE OR BOTH SIDES SIMULTANEOUSLY. PROVIDE 3/8" ADDITIONAL GASKET FOR EACH FOOT OF DAYLIGHT OPENING TO PROVIDE ADEQUATE COMPRESSION FOR THE GLAZING INFILL. NOTE: CLEAN GASKET WITH ISOPROPYL ALCOHOL PRIOR TO SEALING CORNERS MITER HORIZONTAL GASKE T TO FIT VERTICAL GASKET.

19 STACK SYSTEM FRAME ASSEMBLY AND INSTALLATION The assembly and sealant procedures are a part of the installation sequence because of the stacking method. HEAD CAN: Anchor screws should be within 4" of each side of the intended mullion location. Head anchors AC should be used if the height x width x design load is 00 lbs. or more for one bay at the top of the mullion. Normally one anchor screw at the middle of the lite or 24" O.C. is adequate for securing the header. For unusual conditions, consult the OBE engineering department. SILL CAN: Shim can a minimum 1/4. Anchor sill can 24" O.C. and no more than 4" on each side of intended mullion locations. Be sure weeps are located under center line of mullion. Sill both sides of can. HORIZONTAL HEAD AND SILL INSERT: Members are cut 1/16 less than daylight opening to allow for incremental expansion. JAMB MEMBERS: Remember all horizontals are cut 1/16 short. Do not over shim between jamb and structure. MULLIONS Cut mullion length outside frame dimension 1-1/4 ". Install mullions by sliding top end over anchor and rotating bottom into position. RECOMMENDATION: Prior to glazing, fill sill cavity with water to assure that end dams and anchors are sealed. Then, run interior sill bead. 18

20 STACK SYSTEM ANCHORING 3/4" FG-3203 AC PART #: 990 FRAME DIMENSION MULLION ANCHOR ROTATES INTO HEAD CAN. MULLION HEIGHT 1/4" WEEP HOLE AT MID-LITE. CAP SEAL ALL HEAD AND SILL CAN ANCHORS. FG-320 3/8" 19

21 STACK SYSTEM FRAME ASSEMBLY AND INSTALLATION AC PART #: 990 TWIST IN ANCHOR FITS INTO VERTICAL. FG-37 FG-3203 TOP OF HORIZONTAL 29/32" 2-11/16" /16" AC PART #: 6647 FG /16" FG-3192 FG-2000-FP-2 PART #: 716 FG-3144 FG-3164 FG-3191 FG-3144 FG

22 STACK STACK SYSTEM, FRAME FRAME SEALANT PROCEDURES AC PART #: 990 CONT. SEAL SEAL BETWEEN SHEAR BLOCK AND HORIZONTAL. SEAL BETWEEN MULL AND HORIZONTAL. INSIDE HORIZONTAL CONT. SEAL CONT. SEAL NOTE: THE NATURE OF THE STACK SYSTEM REQUIRES CARE WHEN APPLYING SEALANTS AS SHOWN TO ASSURE PERFORMANCE LEVELS SHOWN IN THE TEST REPORT. 21

23 STACK SYSTEM SEALANT PROCEDURE FOR DOOR FRAME AT FLASHING FG-316 FG-214 FG-31 RUN SEALANT ONE INCH ABOVE FLASHING. FLASHING IS BED IN SEALANT AT DOOR JAMB. LEAVE FRONT OF DOOR JAMB CLEAR OF SEALANT FOR DRAINAGE PURPOSES. *USE SHEAR BLOCKS AS SHOWN ON PAGE 44 TO SECURE TO TUBULAR FRAME. DOOR FRAME IS ANCHORED BY FASTENERS THROUGH THRESHOLD AND THROUGH DOOR FRAME HEADER. DO NOT FABRICATE 2 PIECE DOOR FRAMES WITH POUR & DEBRIDGE PROFILES. 22

24 STACK SYSTEM GLAZING PROCEDURE FG-1133 PART #: 364 VERTICAL GASKETS RUN THRU. NOTE: FIRST, WET BOTTOM OF SETTING BLOCKS WITH SOAPY WATER. ONCE GLASS IS SET, PUSH AGAINST GASKET AT SETTING BLOCK AREA. FAILURE TO DO SO MAY CAUSE DIAGONAL CRACKS TOWARDS SETTING BLOCKS DUE TO GLASS BENDING WHILE INSTALLING GASKET(S) IN CORNERS. FG-3146 PART #: 6417 GLAZING INSTALLATION INSTRUCTIONS GLASS SIZE 7/8" OVER DAY LIGHT OPENING SETTING BLOCK SET AT 1/4 POINT OR 1/8 POINT OF HORIZONTAL LENGTH DEPENDING ON LITE SIZE. WATER DIVERTERS GLAZE FROM BOTTOM TO TOP. INSTALL WATER DIVERTERS IN HORIZONTAL ABOVE, AFTER LITE BELOW IS IN POSITION. GLAZING GASKET GASKET MAY BE INSTALLED ON ONE OR BOTH SIDES SIMULTANEOUSLY. PROVIDE 3/8" ADDITIONAL GASKET FOR EACH FOOT OF DAYLIGHT OPENING TO PROVIDE ADEQUATE COMPRESSION FOR THE GLAZING INFILL. NOTE: CLEAN GASKET WITH ISOPROPYL ALCOHOL PRIOR TO SEALING CORNERS. 23 FG-00-FP-2 PART #: 6887 SET IN PLACE WITH SEALANT. 1 0 MITER HORIZONTAL GASKET TO FIT VERTICAL GASKET.

25 FG " X 4-1/2" SCREW SPLINE LENGTH ITEM DESCRIPTION Open back mullion PCS./BOX PART NO. FG30_ FG-30 FG-31 FG-32 FG-33 FG-3142 FG-3161 FG-3164 FG-3144 FG-313 FG-38 FG-39 FG-3180 FG-3181 FG-32 Heavy duty open back mullion Open back filler Open back head/mullion Intermediate horizontal Sill (Use FG-3164 filler for horizontal) Open back filler shallow pocket maximum glass bite=3/8" Glass stop for FG-3142 and FG-3161 Open back mullion shallow pocket maximum glass bite=3/8" Expansion mullion/jamb requires FG-39 Expansion mullion requires FG-38 Adjustable mullion 2 0 to 0 mates with FG-3181 Adjustable mullion 2 0 to 0 mates with FG-3180 Heavy glass stop for inside glazing 3 FG31_ FG32_ FG33_ 4 FG3142_ FG3161_ FG3164_ FG3144_ FG313_ FG38_ FG39_ FG3180_ FG3181_ FG32_ SERIES " X 4-1/2" STACK SYSTEM LENGTH ITEM DESCRIPTION Horizontal filler PCS./BOX PART NO. FG3164_ FG-3164 FG-3144 FG-30 FG-37 FG-3203 FG-3204 FG-3191 FG-320 FG-3192 Stop for FG-3191 and FG-3192 Jamb Mullion Head receptor Head insert Sill Insert Sill receptor Open back horizontal (Use AC-122-1) Sill receptor FG3144_ FG30_ 3 FG37_ FG3203_ FG3204_ FG3191_ FG320_ FG3192_ FG3413_ 24

26 ITEM FG-2122 FG-31 FG-3111 FG-3201 FG-2112 FG-2138 FG-3141 MO-243 MO-244 FG-2139 DESCRIPTION Open back flat filler 90 0 Corner (self mating for 180 post) 90 0 Split corner 90 0 Corner w/fg Way post w/fg-3111 Corner post self mating 13 0 /4 0 Corner use FG-3141 or FG-32 filler Deep pocket filler for FG /2" Head receptor back V-11 weathering not included Head receptor face V-11 weathering not included Head receptor V-11 weathering not included FG " X 4-1/2 AUXILIARY EXTRUSIONS LENGTH PCS./BOX PART NO. FG2122_ 4 FG31_ 4 FG3111_ 4 FG3201_ 4 FG2112_ 4 FG2138_ FG3141_ MO243_ MO244_ FG2139_ ITEM FG-2169 FG-3217 RS-1 FG-3126 FG-3194 FG-3236 FG-3237 ITEM DESCRIPTION Sub-Sill (high back) Sub-Sill (inside glazed) Steel reinforcement for FG-313 and FG-3164 only Snap-in pocket filler Pocket reducer for 1/4" glass Pocket reducer for 7/16" glass Pocket reducer for /8" glass DESCRIPTION LENGTH PCS./BOX PART NO. FG2169_ 8 FG3217_ 1' FG3126_ 12 FG3194_ 12 FG3236_ 12 FG3237_ FG " X 4-1/2" DOOR FRAME COMPONENTS FG-31 FG-3168 FG-316 Tubular door jamb Tubular double door jamb Open back door jamb LENGTH PCS./BOX PART NO. 3 FG31_ 3 FG3168_ FG316_ 2

27 ITEM FG-317 FG-318 FG-3160 FG-3163 FG-3196 FG-1129 FG-1184 FG-214 FG " X 4-1/2" DOOR FRAME COMPONENTS LENGTH PCS./BOX ITEM PART NO. 12 FG317_ DESCRIPTION Door transom glazing adaptor Door transom glazing adaptor stop Tube door header for OHCC Door header for open back frames Door header for OHCC Snap-in filler for FG-3196 header Snap-in filler for FG-3196 header with weathering 1/2" X 1-1/16" Snap-in door stop with weathering 12 FG318_ 3 FG3160_ 3 FG3163_ FG3196_ FG1129_ FG1184_ 21'-" 18 FG214_21 FG-2120 DS-1 DS-8 DS-4 FG-1123 FG-3287 FG-3324 FG-332 DESCRIPTION 1/2" X 1-/8" Snap-in door stop with weathering 1/2" X 1-/8" Door stop with weathering (use SC-1 clip) 3/4" X 1-/8" Door stop with weathering (use SC-1 clip) 1 3/16" X 2" Door stop with weathering (use FS-201 screw) Slide-in pocket filler Door frame jamb for front & back set Transom glazing adaptor mates with FG-3287 Transom glazing adaptor stop mates with FG-3224 LENGTH PCS./BOX PART NO. 21'-" 18 FG2120_21 18 DS1_ 12 DS8 DS4_ 21'-" 24 FG1123_21 3 FG3287_ 12 FG3324_ 12 FG332_ FG-3000 ACCESSORIES ITEM DESCRIPTION PCS. BOX FG-3000 ACCESSORIES ITEM DESCRIPTION PCS. BOX FS-8 FS- FS-12 FS-1 FS-201 FS-6 #14 X 1" H.H.S.T.S. Assembly screw #14 X 1-3/4" P.F.H.W.S. anchors FG thru pocket #14 X 1" plastic plug 3/16" dia. X 7/16" Drive rivet anchors SC-1 clip # X 2" PFH attaches DS-4 FS-201 CLR. FS-201 BRZ. # X 3/4" P.P.H. attaches sill to sill anchor AC-8-1 AC AC FG-2000-FP-3 FG-3000-FP-3 FG-3000 ACCESSORIES Shear block for FG-33 header (screws included) Shear block for FG-3192 horizontal (screws included) Mullion anchor at head for FG-3190 and FG-3203 Sill anchor for FG-3161 Sill anchor for FG-3217 inside glazed

28 FG-3000 ACCESSORIES ITEM DESCRIPTION PCS. BOX FG-3000 ACCESSORIES ITEM DESCRIPTION PCS. BOX FG-1133 FG-1134 FG " Glazing gasket Light gasket /8" Glazing gasket 300' 300' 300' HP-17 FG-00-FP-2 FG-00-FP-4/ Setting block for FG-317, FG-3293, FG-3294 Water diverter for center set outside glazed Water diverter for center set inside glazed FL-66 Heavy gasket 300' FG-2000-FP-7 Splice for FG-2169 SHP Butt Glaze Spacer 20' FG-3000-FP-11 Splice for FG-3127 V-11 CW-998 D-12 Spacer gasket for slot/nonthermal expansion mullion & head receptors Spacer gasket for thermal expansion mullion Weathering gasket for airtight applications 300' 00' 20' FG-2000-FP-4 FG-3000-FP-4 SM-601 End dam for FG-2169 End dam for FG-3217 Joint sealant tape 1/8" X 1/2" ' WP-084 WP-083 Weathering for doorstops Weathering for double acting headers 0' 0' FG-2188 FG-3218 Vinyl filler for caulk stop 12' Vinyl pocket filler for window applications 12' FG-3146 HP-92 Setting block FG-3142 and 3161 Setting block for FG-31 and 3163 stacked 0 0' FG3000-FP-30 FG3000-FP-33 Butt Glaze Horizontal Shear Block Butt Glaze Horizontal Water Diverter 20 0 SC-1 FG-3000 ACCESSORIES Spring clip for DS-1 & DS-8 0 FG3000-FP-78 END DAM FOR FG DJ- DJ-6 Drill fixture for screw spline assembly FG-33, 3142, 3161 Drill fixture for shear block assembly AC & AC

29 INFILL THICKNESS OPTIONS GLASS SIZE ADAPTOR GASKETS 1/4" FG-3194 FG-1133 BOTH SIDES /16" FG-3236 FL-66 BOTH SIDES 3/8" FG-3236 FG-1133 & FL-66 7/16" FG-3236 FG-1133 BOTH SIDES 1/2" FG-3237 FL-66 BOTH SIDES 9/16" FG-3237 FG-1133 & FL-66 /8" FG-3237 FG-1133 BOTH SIDES 11/16" FG-3237 FG-1133 & FG /4" FG-3237 FL-1134 BOTH SIDES 13/16" N/A NOT AVAILABLE 7/8" NONE FG-66 BOTH SIDES 1/16" NONE FL-1133 & FL-66 1" NONE FG-1133 BOTH SIDES 1-1/16" NONE FG-1133 & FG /8" NONE FG-1134 BOTH SIDES 28

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012 Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! Phone: 1-866-OLDCASTLE (653-2278) Web Address: www.oldcastlebe.com FG-1000 & FG-2000 INSTALLATION & GLAZING INSTRUCTIONS These

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015 Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015 Phone: 1-866-OLDCASTLE (653-2278) Web Address: www.oldcastlebe.com S E R I E S 6 0 0 0 X T - S T O R E F R O N T I

More information

Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL

Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF ONTENTS General Information... p.2 Frame Fabrication...

More information

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE:

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE: BuildingEnvelope R FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE: THE INSTALLATION DETAILS FOUND IN THIS PACKAGE ARE GENERIC AND ARE FOR REPRESENTATION ONLY WITH THE INTENT OF GIVING THE INSTALLATION

More information

Sun Control-Solar Eclipse-Solar Shelf

Sun Control-Solar Eclipse-Solar Shelf Sun Control-Solar Eclipse-Solar Shelf Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF CONTENTS GENERAL INFORMATION Product Use...Page 3 Protection and Storage...Page

More information

TCR 250 THERMAL COMPOSITE RIBBON WINDOW

TCR 250 THERMAL COMPOSITE RIBBON WINDOW CORRECT DRO OVER THE 5/8" 1" TOP OF HORIZONTAL 1 1/4" 2 3/8" SEAL THIS ACCESS HOLE ONLY 2 3/4".191 DIA. TAP HOLE FOR #14 SCREW DETAIL AT INCIDENTAL WATER APPLICATION STRAP ANCHOR DESIGNED ON A PER-JOB

More information

DHS-500 IMPACT SYSTEM INSTALLATION MANUAL

DHS-500 IMPACT SYSTEM INSTALLATION MANUAL DHS-500 IMPACT SYSTEM INSTALLATION MANUAL TABLE OF CONTENTS SECTION PAGE GENERAL NOTES 3 EXTRUSION & PARTS IDENTIFICATION 4-5 DETERMINE FRAME SIZE 6 FABRICATE VERTICAL MULLIONS & FILLERS 7-8 FABRICATE

More information

YES 40 FS/FI Storefront System Installation Manual

YES 40 FS/FI Storefront System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 40 FS Framing Members... Page 1 YES 40

More information

YES 45 XT High Performance Thermal Storefront System

YES 45 XT High Performance Thermal Storefront System Dual Thermal Barrier ThermaBond Plus Pour & Debridge Technology Installation Manual 2015 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page

More information

Storefront Installation Guide

Storefront Installation Guide Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation

More information

YES 45 TU Thermal Storefront System Installation Manual

YES 45 TU Thermal Storefront System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION Framing

More information

Series Sloped glazed Curtain wall. Installation Instructions

Series Sloped glazed Curtain wall. Installation Instructions Series 5600 Sloped glazed Curtain wall Installation Instructions Part NO. Y308 February 2013 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines. 3-4 II. Gutter and Mullion Assembly.. 5 III. End

More information

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions 14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6

More information

YES 45 FS/FI Storefront System Installation Manual

YES 45 FS/FI Storefront System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 45 FS Framing Members... Page 1 YES 45

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions Revision May 2013 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...5 ACCESSORIES...8 OVERVIEW...10 FRAME FABRICATION...15

More information

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass Deep pocket allows for direct anchor attachment to substrate without flat filler plate. 1/4 Ø perimeter anchor holes allows for direct anchor attachment

More information

4500 Series. Fabrication and Installation Instructions

4500 Series. Fabrication and Installation Instructions 4500 Series Fabrication and Installation Instructions E4500 Series July, 2017 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 5 ACCESSORIES... 7 OVERVIEW... 8 FRAME FABRICATION...

More information

YWE 40 T Window Wall System Installation Manual

YWE 40 T Window Wall System Installation Manual Installation Manual 2005 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................

More information

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC AUGUST, 2010 (Part No. 452T-CG-970) EC 97904-31 1 INSTALLATION SCREW SPLINE ASSEMBLY Kawneer Company, Inc., 2010 INSTRUCTIONS 2 TABLE OF CONTENTS (452T-CG-970) AUGUST, 2010 These instructions show the

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 08/31/2018 Installation Guideline Disclaimer This document contains general installation

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions 14000 Series Revision December 01, 2009 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 4 ACCESSORIES... 7 OVERVIEW...

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 9/29/2017 Installation Guideline Disclaimer This document contains general installation

More information

BuildingEnvelope Oldcastle ( ) -

BuildingEnvelope Oldcastle ( ) - BuildingEnvelope 1-866-Oldcastle (653-2278) - www.obe.com SERIES 3000 THERMAL MULTIPLANE STOREFRONT 2" X 4-1/2" / / BACK SET Elev-Series-3000-MP-BackSet H0950-SubSill-Splice-EndDam H4501-Hrz-OutsideGlz

More information

YSG 40/50/50T Window Wall System Installation Manual

YSG 40/50/50T Window Wall System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION YSG 40

More information

BuildingEnvelope Oldcastle ( ) -

BuildingEnvelope Oldcastle ( ) - BuildingEnvelope 1-866-Oldcastle (653-2278) - www.obe.com SERIES 3000 THERMAL MULTIPLANE STOREFRONT 2" X 4-1/2" / / FRONT SET Elev-Series-3000-MP-FS H0950-SubSill-Splice-EndDam H4101-Hrz-OutsideGlz H4102-Hd-OutsideGlz

More information

YES 600 Thermal Clip Storefront System Installation Manual

YES 600 Thermal Clip Storefront System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................

More information

CURTAIN WALL INSTALLATION AND GLAZING MANUAL

CURTAIN WALL INSTALLATION AND GLAZING MANUAL RELIANCE tm - TC IG CURTAIN WALL INSTALLATION AND GLAZING MANUAL TABLE OF CONTENTS General Information...Page 3-5 Product Use... Page 3 Protection and Storage... Page 3 Check Material... Page 4 Field Conditions...

More information

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YCW 750 IG Framing Members... Page 1 to 3

More information

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0292 HANDLING, STORAGE,

More information

Thermally Broken Framing and Door Installation

Thermally Broken Framing and Door Installation INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

INSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T

INSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T INSTALLATION TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T INSTRUCTIONS LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC., 2004 451-VG-970.01.04a PART NO. 451-VG-970 1 INSTALLATION

More information

YSD 400 Sliding Door System Installation Manual

YSD 400 Sliding Door System Installation Manual System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation SL-450TB (2" x 4-1/2" with 1" Glazing) & SL-600TB (2" x 6" with 1" Glazing) IMPORTANT: Read all instructions before beginning installation.

More information

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

YCW 752 Outside Glazed Curtain Wall System Installation Manual

YCW 752 Outside Glazed Curtain Wall System Installation Manual YCW 752 Outside Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

Series Advanced and alternate. Installation Instructions

Series Advanced and alternate. Installation Instructions Series 5500 Advanced and alternate Installation Instructions Part NO. Y557 February 2013 TABLE OF CONTENTS SECTION S-5500 ADVANCED INSTALLATION INSTUCTIONS PAGE I. General Notes and Guidelines...... 3-4

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 900 SERIES RIBBON WINDOW INSTALLATION INSTRUCTIONS 3056 Walker Ridge Dr. NW, Suite G Walker, MI 49544 800-866-2227 November 2016 www.tubeliteinc.com Page 1 TABLE OF CONTENTS GENERAL CONSTRUCTION NOTES...3-4

More information

Installation Instructions

Installation Instructions Installation Instructions 1293 N. Harvey Mitchell Pkwy. Bryan, Texas 77803 800.444.1444 ph 979.823.1005 fax www.aswcommercial.com Simplifying Windows Complete Architectural CD Binder Inside B l as t I

More information

BuildingEnvelope Oldcastle ( ) -

BuildingEnvelope Oldcastle ( ) - BuildingEnvelope 1-866-Oldcastle (653-2278) - www.obe.com SERIES 3000 THERMAL MULTIPLANE STOREFRONT 2" X 4-1/2" / 1" GLAZING / CENTER SET Elev-Series-3000-MP-CenterSet H0901-Horiz-OutsideGlz H0902-Head-OutsideGlz

More information

Table of Contents. Typical elevation & cut lengths. General construction notes. General installation notes. Typical jamb assembly

Table of Contents. Typical elevation & cut lengths. General construction notes. General installation notes. Typical jamb assembly c CD $ a c Q / / Table of Contents Page Description 1 Parts list 2 3 4 5 6 Typical elevation & cut lengths General construction notes General installation notes Typical jamb assembly Typical intermediate

More information

INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass

INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass Captured System 3010 Rice Mine Road, Tuscaloosa, Alabama 35406 1-800-772-7737 Fax 1-800-443-6261 www.coralind.com A Division of Coral Industries, Inc. B.G.

More information

SERIES 406X. Installation Instructions. Place photography here. Don t go over grey area. (size w x h )

SERIES 406X. Installation Instructions. Place photography here. Don t go over grey area. (size w x h ) SERIES 406X Installation Instructions Place photography here. Don t go over grey area (size 7.9961 w x 7.4561 h ) Table of Contents Section 1. General Notes and Guidelines. 2. Parts Identification Charts

More information

RELIANCE CURTAIN WALL INSTALLATION AND GLAZING MANUAL

RELIANCE CURTAIN WALL INSTALLATION AND GLAZING MANUAL RELIANCE CURTAIN WALL INSTALLATION AND GLAZING MANUAL Note: The installation details found in this package are generic and are for representation only with the intent of giving the installation team a

More information

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

Series Exterior glazed curtain wall. Installation Instructions

Series Exterior glazed curtain wall. Installation Instructions Series 5500 Exterior glazed curtain wall Installation Instructions Part NO. Y550 November 2016 TABLE OF CONTENTS SECTION S-5500 SCREW SPLINE CURTAIN WALL PAGE I. General Notes and Guidelines.. 3-4 II.

More information

Installation Instructions

Installation Instructions Installation Instructions 200 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised April 2014 dependable@tubeliteinc.com Page 1 TABLE OF

More information

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2" TRIM OFFICE PARTITIONS

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2 TRIM OFFICE PARTITIONS INSTALLATION INSTRUCTIONS SERIES 87 CENTER GLAZED WITH -/" TRIM OFFICE PARTITIONS Phone: (800) -6 Fax: (800) 58-7 crlaurence.com usalum.com crl-arch.com M056_Rev_D SERIES 87 OFFICE PARTITIONS CENTER GLAZED

More information

Series 406 storefront. Installation Instructions

Series 406 storefront. Installation Instructions Series 406 storefront Installation Instructions Part NO. Y016 February 2013 Series 406 Installation Instructions TABLE OF CONTENTS Section I GENERAL NOTES Page 1 II PARTS IDENTIFICATION Page 2-3 III FABRICATION

More information

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE Installation Instructions PART Y015 JUNE 2016 Table of Contents Section 1. GENERAL NOTES AND GUIDELINES... 2. DOOR HARDWARE A. Locks B. Push/Pulls

More information

RELIANCE -LT INSTALLATION AND GLAZING MANUAL

RELIANCE -LT INSTALLATION AND GLAZING MANUAL RELIANCE -LT INSTALLATION AND GLAZING MANUAL NOTE: THE ASSEMBLY DETAILS FOUND IN THIS PACKAGE ARE GENERIC AND ARE FOR REPRESENTATION ONLY WITH THE INTENT OF GIVING THE ASSEMBLY TEAM A VISUAL REPRESENTATION

More information

YOW 225 TU Window System

YOW 225 TU Window System ThermaBond Plus Poured & Debridged Technology YOW 225 TU SYSTEM DESCRIPTION YOW 225 TU PERFORMANCE FEATURES 2-1/4 Overall Depth ThermaBond Plus Poured & Debridged Thermal Break Variations: Casement, Projected

More information

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual YCW 750 OG Outside Glazed Curtain Wall System Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC INSTALLATION EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B INSTRUCTIONS LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC. 2004 175-970.01.04 PART NO. 175-970 INSTALLATION INSTRUCTIONS CONTENTS These

More information

Theut Company LLC 1317 Bus. Hwy 71 N Columbus, Tx Ph. (979) Fax (979)

Theut Company LLC 1317 Bus. Hwy 71 N Columbus, Tx Ph. (979) Fax (979) Theut Company LLC 1317 Bus. Hwy 71 N Columbus, Tx 78934 Ph. (979) 732-2201 Fax (979) 732-2311 Westside Montessori School Building B Addition Environments, Inc Drymalla Construction February 14, 2013 Installation

More information

BuildingEnvelope Oldcastle ( ) -

BuildingEnvelope Oldcastle ( ) - BuildingEnvelope 1-866-Oldcastle (653-2278) - www.obe.com RELIANCE -LT CURTAIN WALL 2" X 7-1/2" / POLYAMIDE PRESSURE PLATE / 1" GLAZING Elev-Reliance-LT-750-PolyPP H0042-Steel-Anchor H5021-ShrBlk-Anchors

More information

YHC 300 IG Inside Glazed Curtain Wall System Installation Manual

YHC 300 IG Inside Glazed Curtain Wall System Installation Manual YHC 300 IG Inside Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE PATIO DOORS INSTALLATION GUIDE These instructions cover general installation conditions. Improper installation could affect your doors operation and warranty. Deviations from these instructions should

More information

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B. EnCORE FEBRUARY, 2012 EC PART NO.

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B. EnCORE FEBRUARY, 2012 EC PART NO. FEBRUARY, 2012 1 INSTALLATION CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B INSTRUCTIONS 2 FEBRUARY, 2012 INSTALLATION INSTRUCTIONS CONTENTS These instructions show the general installation sequence and

More information

I N S T A L L A T I O N

I N S T A L L A T I O N CW-250 3/4" CW250-FP-1 DRILL 7/32" CL AND C'SINK 7/ #12 PFH. C 3/4" 3 1/2" CW-1 3/4" WHEN HORIZONT IS NOT NOTCHED 3/8" FS-323 CAP SEAL NTAL 7/8" CW-250-FP-3 C W - 2 5 0 1 I n c h DRILL 7/32" CLEAR HOLE

More information

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide Flushglaze 4500 For Framed Openings and Horizontal Panels Window System Installation Guide January 2017 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels

More information

Installation Instructions

Installation Instructions Installation Instructions 400 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised September 2014 dependable@tubeliteinc.com Page 1 TABLE

More information

YVS 400 TU Window System

YVS 400 TU Window System YVS 400 TU SYSTEM DESCRIPTION YVS 400 TU PERFORMANCE FEATURES 4 Overall Depth ThermaBond Plus Poured & Debridged Thermal Break Variations: Single Hung, Double Hung & Fixed Windows 1 /8 & 1 1 /16 Glazing

More information

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL Window assembly GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS DETAIL TITLE FILE NO. PAGE NO. INTRODUCTION..................................................................

More information

Swing Door Installation Manual

Swing Door Installation Manual Manual 20D/35D/50D 20DH/35DH 40M/50M 25FD 35XT 50XT 01-4000-03 2010 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes.......................................

More information

YHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual

YHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual YHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

Storefront Installation Guide INSTALLATION INSTRUCTIONS

Storefront Installation Guide INSTALLATION INSTRUCTIONS STOREFRONT General Notes 1. Check contract documents and shop drawings, and understand and clarify any Field Verify Notes, approvals of drawings, and products required to be familiar with the project.

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 400T SERIES CURTAIN WALL INSTALLATION INSTRUCTIONS 3056 Walker Ridge Dr. NW, Suite G Walker, MI 49544 800-866-2227 October 2017 www.tubeliteinc.com Page 1 BLANK Page 2 www.tubeliteinc.com October 2017

More information

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual YCW 750 OG Outside Glazed Curtain Wall System Installation Manual 2012 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION

More information

INSTALLATION MANUAL STOREFRONT DOORS

INSTALLATION MANUAL STOREFRONT DOORS INSTALLATION MANUAL STOREFRONT DOORS www.aluflam-usa.com SYSTEM DESCRIPTION - Extruded and filled aluminum framing, tested and approved by UL - 3-3/8 frame depth - Clear, fire-rated safety glazing - Door

More information

SECTION C1 INSTALLATION INSTRUCTIONS

SECTION C1 INSTALLATION INSTRUCTIONS SECTION C1 SERIES CWW451T THERMALLY BROKEN FRONT GLAZED WINDOW WALL / STOREFRONT SYSTEM X 4 1 / for 1" GLAZING INSTALLATION INSTRUCTIONS EXTERIOR GLAZED Effective October 2014 www.cardcompro.com 1 INTERIOR

More information

SERIES CF450 INSTALLATION INSTRUCTIONS. SERIES CF450 1¾ x 4½ - B1. Fabrication for Panel Assembly. High Performance Non-Thermal Storefront System

SERIES CF450 INSTALLATION INSTRUCTIONS. SERIES CF450 1¾ x 4½ - B1. Fabrication for Panel Assembly. High Performance Non-Thermal Storefront System SERIES CF450 INSTALLATION INSTRUCTIONS Fabrication for Panel Assembly High Performance Non-Thermal Storefront System Effective October 2014 www.cardcompro.com 1 2 www.cardcompro.com Effective October 2014

More information

YSD 600 T/TH Sliding Door System Installation Manual

YSD 600 T/TH Sliding Door System Installation Manual System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii & iii PARTS DESCRIPTION

More information

e-lite fabrication/assembly and Installation instructions

e-lite fabrication/assembly and Installation instructions e-lite fabrication/assembly and Installation instructions Part NO. YWLS February 2013 TABLE OF CONTENTS SECTION PAGE I. General Notes and Guidelines.. 3-4 II. E-Lite Stick Built Channel Base Assembly...

More information

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS 2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed

More information

ELEPHANT DOOR SYSTEMS SERIES E1200

ELEPHANT DOOR SYSTEMS SERIES E1200 INSTALLATION INSTRUCTIONS ELEPHANT DOOR SYSTEMS SERIES E1200 Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com AVDB3096 03.13 TABLE OF CONTENTS SUBJECT PAGE GENERAL INSTALLATION

More information

YHS 50 TU Storefront System & Model 35H Door Installation Manual

YHS 50 TU Storefront System & Model 35H Door Installation Manual Installation Manual 2012 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YHS 50 TU Framing Members... Page 1 YHS 50

More information

Installation Manual. YSD 600 T/TH Sliding Door. YSD 600 T/TH Sliding Door System

Installation Manual. YSD 600 T/TH Sliding Door. YSD 600 T/TH Sliding Door System YSD 600 T/TH Sliding Door System Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii & iii PARTS DESCRIPTION Framing

More information

SERIES BW3250 BLAST WALL TABLE OF CONTENTS INSTALLATION INSTRUCTIONS GENERAL NOTES

SERIES BW3250 BLAST WALL TABLE OF CONTENTS INSTALLATION INSTRUCTIONS GENERAL NOTES I N S TA L L AT I O N I N S T R U C T I O N S BW3250 BLAST RESISTANT CURTAIN WALL Page 2 SERIES BW3250 BLAST WALL TABLE OF CONTENTS United States Aluminum PAGE GENERAL NOTES...2 and 3 FABRICATION...4 through

More information

SERIES CF451T INSTALLATION INSTRUCTIONS. SERIES CF451T 2 x 4½ - B2. Fabrication for Panel Assembly. High Performance Thermal Storefront System

SERIES CF451T INSTALLATION INSTRUCTIONS. SERIES CF451T 2 x 4½ - B2. Fabrication for Panel Assembly. High Performance Thermal Storefront System SERIES CF451T INSTALLATION INSTRUCTIONS Fabrication for Panel Assembly High Performance Thermal Storefront System Effective October 2014 www.cardcompro.com 1 2 www.cardcompro.com Effective October 2014

More information

Illustration Part Description Base List Weight/ Ft./ Box Number Price/S.L. S.L. S.L. Qty.

Illustration Part Description Base List Weight/ Ft./ Box Number Price/S.L. S.L. S.L. Qty. Prices DO NOT include glazing gaskets or weathering. See Accessories sheet. Exterior Glazed Back Members for 1" Glass Illustration Part Description Base List Weight/ Ft./ Box Price/S.L. S.L. S.L. Qty.

More information

Series 955 Tech Set storefront. Installation Instructions

Series 955 Tech Set storefront. Installation Instructions Series 955 Tech Set storefront Installation Instructions Part NO. Y008 February 2013 TABLE OF CONTENTS SECTION PAGE I II III GENERAL NOTES AND GUIDELINES 1-2 PARTS IDENTIFICATION 3-5 DRILL JIGS 6-7 DRILL

More information

MODEL: STORMMAX-MSD-FG-5000-WET

MODEL: STORMMAX-MSD-FG-5000-WET MODEL: STORMMAX-MSD-FG-5000-WET MEDIUM STILE HURRICANE RESISTANT DOORS WITH FG-5000 FRAMES MONOLITHIC LAMINATED GLASS - WET GLAZED OHSC H6331 O.H.C.C H6333 MID-PANEL MEETING STILES HD6184 HD6186 VD6145

More information

YHS 50 FS Storefront System & Model 35H/50H Door Installation Manual

YHS 50 FS Storefront System & Model 35H/50H Door Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YHS 50 Framing Members... Page 1 YHS 50 Accessories...

More information

Curtain Wall Installation Guide

Curtain Wall Installation Guide Curtain Wall Installation Guide Curtain Wall Installation Guide 1 IMPORTANT NOTICES! Important Notices & Information Manufacturer s Notes: The building envelope must be correctly prepared with weather

More information

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MARCH, 2009 PART NUMBER 590-500 1 INSTALLATION INSTRUCTIONS 2 INDEX MARCH, 2009 INSTALLATION INSTRUCTIONS CONTENTS These instructions show the general installation sequence and procedure for typical installation.

More information

MODEL: STORMMAX-MSD-FG-5100-WET

MODEL: STORMMAX-MSD-FG-5100-WET MODEL: STORMMAX-MSD-FG-5100-WET MEDIUM STILE HURRICANE RESISTANT DOORS WITH FG-5000 FRAMES MONOLITHIC LAMINATED GLASS - DRY GLAZED O.H.C.C H6333 HD6184 MID-PANEL HD6186 MEETING STILES VD6145 JAMB V6331

More information

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement 1 Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement The following instructions are a supplement

More information

INSTALLATION INSTRUCTIONS ENTICE SERIES PREMIUM ENTRANCE SYSTEM EXTERIOR GLAZE

INSTALLATION INSTRUCTIONS ENTICE SERIES PREMIUM ENTRANCE SYSTEM EXTERIOR GLAZE INSTALLATION INSTRUCTIONS ENTICE SERIES PREMIUM ENTRANCE SYSTEM EXTERIOR GLAZE Phone: (800) 421-6144 Fax: (800) 582-7501 crlaurence.com usalum.com crl-arch.com 11M0230 HANDLING, STORAGE, AND PROTECTION

More information

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

40mm Thermoclick.  Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) http://www.sundancesupply.com 40mm Thermoclick Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) U-Profile 12' Lengths $39 Out System offers a complete set of extrusions and accessories

More information

IF THE END REACTION IS 350# TO 750# THE FOLLOWING PERIMETER ANCHORING CAN BE USED. HEAD AND SILL CONDITIONS WITH EXPOSED INTERIORS SHIMS

IF THE END REACTION IS 350# TO 750# THE FOLLOWING PERIMETER ANCHORING CAN BE USED. HEAD AND SILL CONDITIONS WITH EXPOSED INTERIORS SHIMS 162-960 1 OF 5 USE THESE INSTRUCTIONS IN CONJUNCTION WITH INSTALLATION INSTRUCTIONS 162-970. PERIMETER ANCHORING TO CALCULATE END REACTIONS MODULE(FT) X LENGTH(FT) X WIND LOAD(PSF) A IF THE END REACTION

More information

INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS.

INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS. INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS. Installer: DO NOT DISCARD Please leave the Installation Guide

More information

Series 526 Thermal impact storefront. Installation Instructions

Series 526 Thermal impact storefront. Installation Instructions Series 526 Thermal impact storefront Installation Instructions Part NO. Y021 February 2013 TABLE OF CONTENTS SECTION PAGE I. General Notes and Guidelines. 3 II. Parts Identification Chart.......4-8 III.

More information

INSTALLATION INSTRUCTIONS SERIES 3600 SUNSHADE SYSTEM

INSTALLATION INSTRUCTIONS SERIES 3600 SUNSHADE SYSTEM INSTALLATION INSTRUCTIONS SERIES 3600 SUNSHADE SYSTEM Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0103 HANDLING, STORAGE, AND PROTECTION OF The following precautions

More information

MODEL: STORMMAX-MSD-FG-5000-DRY

MODEL: STORMMAX-MSD-FG-5000-DRY MODEL: STORMMAX-MSD-FG-5000-DRY MEDIUM STILE HURRICANE RESISTANT DOORS WITH FG-5000 FRAMES MONOLITHIC LAMINATED GLASS - DRY GLAZED OHSC H6331 O.H.C.C H6333 MID-PANEL MEETING STILES HD6184 HD6186 VD6145

More information

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation. Installation Guide for E-Series/Eagle High-Performance Mullion Windows with LVL Reinforcement and Installed Using Type B Clips Thank you for choosing Andersen. Instructions are for typical, new wood-framed

More information

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions PO Box 480 Ph: 417-235-7821 Monett, MO 65708 Fax: 417-737-7140 Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions These installation instructions are recommendations

More information

Window Frame Installation Instructions For Nail-on and Block Frames

Window Frame Installation Instructions For Nail-on and Block Frames General The key to any window or door installation is preparation. This extends from storage of the product to the final installation and to all points in between. Careful planning and attention to detail

More information

Sliding Glass Door Assembly and Installation Guide

Sliding Glass Door Assembly and Installation Guide Sliding Glass Door Assembly and Installation Guide Index Door System Components and Hardware The following components are needed to complete the installation of your Sliding Patio Door unit. Check all

More information