L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

Size: px
Start display at page:

Download "L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET"

Transcription

1 KPV-DS-01-BRH KPV-PJ-01-BRH KPV-PJ-02-BRH KPV-PJ-03-BRH KPV-BS-01-BRH KPV-BS-02-BRH KPV-BS-03-BRH KPV-OC-01-BRH KPV-IC-01-BRH KPV-FO-01-BRH KPV-FO-02-BRH KPV-FO-03-BRH KPV-SJ-01-BRH KPV-PR-01-BRH KPV-LE-01-BRH KPV-RD-01-BRH KPV-TP-01-BRH KPV-TL-01-BRH KPV-TL-02-BRH C & I DISCLAIMER EXPANDED PANEL JOINT ENGAGED PANEL JOINT INTERMEDIATE SUPPORT BASE DETAIL FLUSH BASE AT NOTCHED CONCRETE BASE AT OVERHANG OUTSIDE CORNER INSIDE CORNER FRAMED OPENING HEAD FRAMED OPENING JAMB FRAMED OPENING SILL STACK JOINT PARAPET DETAIL LOW EAVE DETAIL RAKE DETAIL PANEL TERMINATION TRIM END LAP TRIM END LAP WITH HEMS INDEX SHEET

2 DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED ON TYPICAL DESIGN PRACTICES FOR MOST U.S. AND CANADIAN CLIMACTIC ZONES. (THE PRIMARY VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER). PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND ILLUSTRATION PURPOSES ONLY. WALL SYSTEM DEFLECTIONS ARE TO BE DETERMINED BY THE ENGINEER OF RECORD. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND ILLUSTRATION PURPOSES ONLY. CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANS AND FASTENING PATTERNS. DISCLAIMER

3 INTERIOR FACE SHADOWLINE KS42SL 2" - 6" EXTERIOR FACE SHADOWLINE 42" COVERAGE (36", 30", & 24" OPTIONAL) FASTENERS SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER LOCATIONS MALE JOINT HORIZONTAL SUPPORT CONTINUOUS BUTYL SEALANT FEMALE JOINT EXPANDED PANEL JOINT

4 FASTENERS SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER LOCATIONS MALE JOINT FEMALE JOINT HORIZONTAL SUPPORT CONTINUOUS BUTYL SEALANT 1" EXPANSION FASTENER #10 TEK FASTENER CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) WALL PANEL INSTALLATION DIRECTION CONTINUOUS BUTYL SEALANT (OPTIONAL) SUPPORT ENGAGED PANEL JOINT

5 FASTENERS HORIZONTAL SUPPORT INSULATED METAL PANEL (IMP) SUPPORT CONTINUOUS SUPPORT RAIL SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER LOCATIONS #10 TEK FASTENER EXPANSION FASTENER PANEL THICKNESS 1" " INTERMEDIATE SUPPORT

6 CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) EXPANSION FASTENER SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER LOCATIONS (BOTTOM COURSE TRANSITION) SUPPORT FASTENERS SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT BASE FLASHING SEALANT BELOW BASE FLASHING FASTENER TO CONCRETE BASE ANGLE W/ MINIMUM 3" VERT. LEG FOR PANEL ATTACHMENT SET IN SEALANT BASE DETAIL FLUSH

7 CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) EXPANSION FASTENER (BOTTOM COURSE TRANSITION) SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER LOCATIONS FASTENERS SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SUPPORT BASE FLASHING SEALANT BELOW BASE FLASHING FASTENER TO CONCRETE BASE ANGLE W/ MINIMUM 3" VERT. LEG FOR PANEL ATTACHMENT SET IN SEALANT SEALANT BASE AT NOTCHED CONCRETE

8 CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) EXPANSION FASTENER SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER LOCATIONS SUPPORT (BOTTOM COURSE TRANSITION) BASE FLASHING FASTENERS SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT FASTENER TO CONCRETE BASE ANGLE W/ MINIMUM 3" VERT. LEG FOR PANEL ATTACHMENT SET IN SEALANT SEALANT BASE AT OVERHANG

9 HAT CHANNEL SET IN BUTYL SEALANT AT FASTENER LOCATIONS FASTENERS OUTSIDE CORNER TRIM POP RIVETS F.I.P. INSULATION (BY OTHERS) POP RIVETS SUPPORT HAT CHANNEL SET IN BUTYL SEALANT AT FASTENER LOCATIONS FASTENERS 3 4 " PHIL PAN HEAD 1 4 " - 14 "LOW PROFILE FASTENER W/ 1 1 8" BONDED WASHER SEALANT INSIDE CORNER TRIM 3 4 " PHIL PAN HEAD HORIZONTAL SUPPORT OUTSIDE CORNER

10 3 4 " PHIL PAN HEAD 1 4 " - 14 "LOW PROFILE FASTENER W/ 1 1 8" BONDED WASHER SEALANT INSIDE CORNER TRIM F.I.P. INSULATION (BY OTHERS) FASTENERS POP RIVETS HAT CHANNEL SET IN BUTYL SEALANT AT FASTENER LOCATIONS SEALANT 1 4 " - 14 "LOW PROFILE FASTENER W/ 1 1 8" BONDED WASHER 3 4 " PHIL PAN HEAD FASTENERS POP RIVETS HORIZONTAL SUPPORT OUTSIDE CORNER TRIM HAT CHANNEL SET IN BUTYL SEALANT AT FASTENER LOCATIONS SUPPORT INSIDE CORNER

11 CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) EXPANSION FASTENER FASTENERS FRAMED OPENING SUPPORT DRIP FLASHING SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT EXPOSED SEALANT DOOR/WINDOW FRAME FRAMED OPENING HEAD

12 FRAMED OPENING DOOR/WINDOW FRAME 1 4 " - 14 THROUGH FASTENER EXPOSED SEALANT SEALANT BACKER ROD AND SEALANT SEALANT 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER FASTENERS HAT CHANNEL SET IN BUTYL SEALANT AT FASTENER LOCATIONS FRAMED OPENING JAMB

13 EXPOSED SEALANT SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT DOOR/WINDOW FRAME MITER CUT JOINTS WHERE REQUIRED SILL TRIM SILL 1 4 " - 14 THROUGH FASTENER SEALANT SUPPORT FASTENERS EXPANSION FASTENER CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) FRAMED OPENING SILL

14 FIELD NOTCH KARRIER RAIL AT STACK FLASHING/ STACK JOINT FOR OVERLAP CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES)* EXPANSION FASTENER FASTENERS FASTENER HORIZONTAL SUPPORTS SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SUPPORT FASTENERS EXPANSION FASTENER *NOTE: FIELD NOTCH KARRIER RAIL * STACK JOINT

15 FIP INSULATION PARAPET ASSEMBLY PARAPET BLOCKING SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT FASTENERS WRAP MEMBRANE OVER FACE FASTENER TO PARAPET BACKER EXPANSION FASTENER SUPPORT CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) MEMBRANE ROOF & PARAPET BACKER PARAPET DETAIL

16 REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION FIP INSULATION EXPANSION FASTENER SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT FASTENERS FASTENER SHOULD PENETRATE THE MORTAR JOINTS BETWEEN THE ENDS, NOT ABOVE OR BELOW THE S SUPPORT EAVE STRUT CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) LOW EAVE DETAIL

17 REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION RAKE ANGLE FIP INSULATION EXPANSION FASTENER FASTENER SHOULD PENETRATE THE MORTAR JOINTS BETWEEN THE ENDS, NOT ABOVE OR BELOW THE S SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT FASTENERS RAKE ANGLE SUPPORT CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) RAKE DETAIL

18 1 4 " - 14 "LOW PROFILE FASTENER W/ 1 1 8" BONDED WASHER SEALANT FASTENERS STRUCTURAL SUPPORTS HAT CHANNEL SET IN BUTYL SEALANT AT FASTENER LOCATIONS CAP TRIM BACKER ROD & SEALANT SUPPORT BACKER ROD AND SEALANT PANEL TERMINATION

19 (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP

20 FIELD NOTCH HEM(S) MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM END LAP WITH HEMS

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. KPV-DS-01-MTLH C & I DISCLAIMER KPV-PJ-01-MTLH EXPANDED PANEL JOINT KPV-PJ-02-MTLH ENGAGED PANEL JOINT KPV-PJ-03-MTLH INTERMEDIATE SUPPORT KPV-FS-01-MTLH MULTI-STORY FIRE STOPPING DETAIL KPV-FS-02-MTLH

More information

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. FRKPV-DS-01-MTLH FRKPV-PJ-01-MTLH FRKPV-PJ-02-MTLH FRKPV-PJ-03-MTLH FRKPV-FS-01-MTLH FRKPV-FS-02-MTLH FRKPV-BS-01-MTLH FRKPV-BS-02-MTLH FRKPV-BS-03-MTLH FRKPV-BS-04-MTLH FRKPV-OC-01-MTLH FRKPV-IC-01-MTLH

More information

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET KPH-DS-01-MTLV KPH-PP-01-MTLV KPH-PP-02-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-FS-01-MTLV KPH-FS-02-MTLV KPH-FS-03-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV

More information

900 SERIES WALL PANELS

900 SERIES WALL PANELS CI-DS-01-900 CI-PP-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-PJ-03-900 CI-BS-01-900 CI-BS-02-900 CI-BS-03-900 CI-BS-04-900 CI-BS-05-900 CI-OC-01-900 CI-OC-02-900 CI-IC-01-900 CI-FO-01-900 CI-FO-02-900 CI-FO-03-900

More information

400 SERIES VERTICAL INSTALLATION

400 SERIES VERTICAL INSTALLATION CI-DS-01-400V CI-PJ-01-400V CI-PJ-02-400V CI-PJ-03-400V CI-BS-01-400V CI-BS-02-400V CI-BS-03-400V CI-BS-04-400V CI-BS-05-400V CI-OC-01-400V CI-OC-02-400V CI-IC-01-400V CI-IC-02-400V CI-FO-01-400V CI-FO-02-400V

More information

KS42 MF SERIES - HORIZONTAL INSTALLATION

KS42 MF SERIES - HORIZONTAL INSTALLATION CI-DS-01-KSMF H CI-PJ-01-KSMF H CI-PJ-02-KSMF H CI-PJ-03-KSMF H CI-PJ-04-KSMF H CI-PJ-05-KSMF H CI-PJ-06-KSMF H CI-PJ-07-KSMF H CI-PJ-08-KSMF H CI-PJ-09-KSMF H CI-PJ-10-KSMF H CI-PJ-11-KSMF H CI-PJ-12-KSMF

More information

DW VERTICAL INSTALLATION

DW VERTICAL INSTALLATION AR-PJ-01-DW5V AR-PJ-02-DW5V AR-PJ-03-DW5V AR-PJ-04-DW5V AR-BS-01-DW5V AR-BS-02-DW5V AR-OC-01-DW5V AR-OC-02-DW5V AR-OC-03-DW5V AR-IC-01-DW5V AR-IC-02-DW5V AR-IC-03-DW5V AR-FO-01-DW5V AR-FO-02-DW5V AR-FO-03-DW5V

More information

DW HORIZONTAL INSTALLATION

DW HORIZONTAL INSTALLATION AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV

More information

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR 900 SERIES PANEL CI-DS-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-EL-01-900 CI-EL-02-900 CI-EL-03-900 CI-EL-04-900 CI-EL-05-900 CI-EL-06-900 CI-EL-07-900 CI-EL-08-900 CI-RD-01-900 CI-RD-02-900 CI-RD-03-900 CI-EV-01-900

More information

Insulated Panels North America. Installation Guide KarrierPanel Wall System

Insulated Panels North America. Installation Guide KarrierPanel Wall System Insulated Panels North America Installation Guide KarrierPanel Wall System Installation Guide KarrierPanel Wall System Disclaimer This installation guide is only to be used in conjunction with panel installation

More information

~ ~ -

~ ~ - ~----------------~ - METL DISCLAIMER: These details are based on industry accepted practices and provide a guideline for proper insulated metal panel and component installation. The location of vapor barriers

More information

Construction details: Master-C type profiles and joints:

Construction details: Master-C type profiles and joints: Construction details: Master-C type profiles and joints: Master-C 3g 32 mm. (1 1/4 ) 1000 mm. (39 3/8 ) outer face inner face 10.5 fixing details: sealing washers shall be installed through a 2-3/8 x 1-9/16

More information

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24 O.C. ALL FASTENERS TO PENETRATE WOOD 3/4 MIN. AND METAL FRAMING 1/2 MIN. PLYWOOD SHEATHING DMI SOFFIT PANEL #10-13 GP PANCAKE HEAD (JC) - J CLOSURE (LC) - L CLOSURE #9-15 X 1 1/2" WOODZAC GP APPROVED MOISTURE BARRIER SOFFIT TO WALL PANEL WPRP-H-01-00 APPROVED MOISTURE BARRIER

More information

TABLE OF CONTENTS A. PBR

TABLE OF CONTENTS A. PBR TABLE OF CONTENTS A. PBR Panel 1. PBR Panel Architect/Engineer Information....................................... 2 2. PBR Panel UL 90 Requirements............................................... 3 3. PBR

More information

TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION

TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION MATRIX DETAILS C-1...FASCIA/SOFFIT DETAIL with ANGLE C-2...BUILDING/SOFFIT

More information

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. EXTERIOR INSULATION & FINISH SYSTEM CONSTRUCTION Data Published Courtesy

More information

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3 Step 1. Install Sill Flashing Product: 9" or 12" RainBuster #440 SubZero Flashing Tape 1.A Flashing Length = (Rough Opening Width) + 12" 1.B Install sill flashing flush with the sill of the rough opening.

More information

REGAL. Installation Manual

REGAL. Installation Manual REGAL Installation Manual General Information The details shown on the following pages are suggestions or guidelines for installing the Regal system. The installation details shown here are proven methods

More information

SEAL PLATE SP4413 VERTICAL SP4414 1"[25] VERT. PANEL JTS. 1/2"[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM.

SEAL PLATE SP4413 VERTICAL SP4414 1[25] VERT. PANEL JTS. 1/2[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM. 3 COL 5 16GA. ANGLE SP4413 VERTICAL SEE SUPPORT DRAINGS 1 7/16 SEAL PLATE @ VERT. JNT 1/2 [13] Ă DETAILER NOTE OPTIONAL INSULATION HEN REQUIRED. OF SEAL PLATE PANEL MODULE 2.500 FROM SHELF OF TR. TO TOP

More information

PROVEN DEPENDABLE SUSTAINABLE

PROVEN DEPENDABLE SUSTAINABLE B/SOFFIT FP CLIP 24" O.C. MAX SECTION "A-A" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. A B/SOFFIT A (JC) - J CLOSURE DMI WALL PANEL PLYWOOD SHEATHING SOFFIT TO WALL PANEL FR10-V-01-00 B/SOFFIT

More information

DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988

DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988 FP CLIP 24" O.C. MAX B/SOFFIT 5 1/2" SECTION "A-A" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. A B/SOFFIT A (JC) - J CLOSURE DMI WALL PANEL PLYWOOD SHEATHING SOFFIT TO WALL PANEL FR15-V-01-00

More information

Installation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc.

Installation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc. I B D L K C E G M F A H J Installation Instruction 3-D Model 3D 03/01/17 Detail: System Type: Scale: Drawn By: 0 Flush Siding Horizontal System N/C WPS, Inc. Wall Panel System, Inc. 15/16" 1 1/4" Bottom

More information

WESTERN WAVE Panel. Horizontal Installation and Technical Information

WESTERN WAVE Panel. Horizontal Installation and Technical Information WESTERN WAVE Panel Horizontal Installation and Technical Information Western States Western Wave Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page

More information

WESTERN WAVE Panel. Vertical Installation and Technical Information

WESTERN WAVE Panel. Vertical Installation and Technical Information WESTERN WAVE Panel Vertical Installation and Technical Information Western States Western Wave Wall and Soffit Panels (Vertical) Installation, Flashings & Shop Drawing Detail Guide Section Notes to Designer

More information

ForceField Air & Water Barrier System. installation instructions

ForceField Air & Water Barrier System. installation instructions ForceField Air & Water Barrier System installation instructions Protection and Performance inside and out The ForceField air and water barrier system consists of engineered wood sheathing panels laminated

More information

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit Horizontal battens between verticals at soffit 2 C.04 600 600 600 600 Cavity batten at 600 mm centres 1 C.03 Batten fixing points 1 C.04 1 C.07 1 C.12 1 C.13 1 C.14 Meter Box Window 1 C.08 1 C.09 800 800

More information

Pebbletex Adhered Mat Design. Typical Details

Pebbletex Adhered Mat Design. Typical Details Pebbletex Adhered Mat Design Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK) Pebbletex Adhered Mat Design TABLE OF CONTENTS 1. Pebbletex Adhered Mat Design Application (Plan VIew) 2. Pebbletex Adhered

More information

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504 ATTACH TO STRUC- TURE ABOVE 1/8"Ø BOLT W/ LOCKING NUT #12 WIRE TIE IN PLANE EACH TEE ANGLED 45 FROM HORIZ ATTACH 2" FROM INTERSECTION COMPRESSION POST LOCATE WITHIN 2" OF TEE INTERSECTION SIZE STRUTS FOR

More information

3M Air and Vapour Barrier 3015 Technical guide

3M Air and Vapour Barrier 3015 Technical guide 3M Air and Vapour Barrier 3015 Technical guide Product overview Typical physical properties For installation ease and flexibility, 3M Air and Vapour Barrier 3015 High performance 3M acrylic adhesive grabs

More information

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS ULTRA WINDOW & DOOR S AND RECEIVERS INSTALLATION INSTRUCTIONS! CAUTION: *REMEMBER SAFETY FIRST* Proper Eye and! Hearing Protection must always be worn during installation of all window and door products.

More information

eco-shake INSTALLATION INSTRUCTION

eco-shake INSTALLATION INSTRUCTION 1 eco-shake INSTALLATION INSTRUCTION NOTE: Shuffling the eco-shakes during installation may be necessary to obtain a uniform color throughout the roof. Due to the natural wood content in the ecoshakes,

More information

TremLock T-138 INSTALLATION MANUAL T-138 www.tremcoroofing.com 3735 Green Road Beachwood, Ohio 44122 1.800.852.6013 50 Beth Nealson Drive Toronto, Ontario M4H 1M6 1.800.668.9879 7241 6/8/18 TABLE OF CONTENTS

More information

TABLE OF CONTENTS A-1

TABLE OF CONTENTS A-1 TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1...GENERAL INFORMATION C-1...EAVE DRIP DETAIL C-2...EAVE DRIP with GUTTER DETAIL C-3 & C-4...FIXED RIDGE

More information

26- H i n g e d P a t i o D o o r s - I n s w i n g

26- H i n g e d P a t i o D o o r s - I n s w i n g Contents Hinged Patio Doors - Inswing Basic Unit Details... 2 Options / Accessories Accessibility Option... 5 Andersen Grilles... 6 Extension s... 7 Anchoring Methods... 8 Joining Details... 9 Suggested

More information

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application 1 2 3 General Instructions NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE

More information

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME

More information

ThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST

ThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST ThermoSpan EPS DETAIL LIST 00 / 15 COVER SHEET 01 / 15 RIDGE DETAIL 02 / 15 HEAD FLASHING DETAIL 03 / 15 EAVES GUTTER DETAIL 04 / 15 INSULATED GUTTER 05 / 15 INSULATED BOX GUTTER 06 / 15 BARGE CAPPING

More information

Cambridge English Application Instructions

Cambridge English Application Instructions Cambridge English Application Instructions ROOF SLOPE: Never apply asphalt shingles to roof slopes less than 2:12. For slopes 2:12 to 4:12 (LOW SLOPE), see special underlayment requirements outlined below.

More information

A P P L I C A T I O N I N S T R U C T I O N S

A P P L I C A T I O N I N S T R U C T I O N S 1 2 3 General Instructions NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE

More information

Tuff-Rib Install Guide

Tuff-Rib Install Guide Install Guide bestbuymetalroof.com Page 2 of 27 Page 3 of 27 1. Page 4 2. a. Installation Guide b. Panel Squaring Pages 5, 6 Pages 7, 8 3. Pages 9, 10 4. a. Fascia (optional) b. Eave / 1.5x3.5 Angle c.

More information

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection... Table of Contents Section Page Notes to Designer/User... 2-3 Map of Typical Roof Conditions... 4 Fastener Placement... 5 Fastener Selection... 6 Ridge/Hip Flashing... 7 Valley Flashing... 8 Eave Flashings...

More information

System for 2+ Level Buildings

System for 2+ Level Buildings Issued Sept 205 Contact Info@symonite.co.nz System for 2+ Level Buildings Typical Details Issued: September 205 TYPICAL DETAILS CONTENTS.0 TYPICAL VERTICAL JOINTS 2.0 EXT. CORNER / TYPICAL HORIZONTAL JOINT

More information

All Window Installation Instruction

All Window Installation Instruction 1 All Window Installation Instruction Hurd Window Installation Instructions for Nail Fin & Wood Brick Mould Units Nail Fin Windows See Pages 2-11 Wood Brick Mould Windows See Pages 2-6, 8 & 12BM - 14BM

More information

Effective February, 2015

Effective February, 2015 Effective February, 2015 Table of Contents Ensuring System Performance 1 Components 2 Frequently Asked Questions 3 List of Tools 3 Before you Begin Preparation 3 Quality Tips 4 Cold Weather Tips 4 Cleaning

More information

SpeedDeck. Fixing and Handling Guide

SpeedDeck. Fixing and Handling Guide SpeedDeck Section 1 Delivery/Storing On Site/Handling l SpeedDeck is factory or on-site manufactured. l Straight SpeedDeck bundles are a maximum 1 tonne, sheets nestled and banded with polypropylene or

More information

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN MINNEAPOLIS, MN 2-0- 2-- General Notes Abbreviations Deviations from Architectural Specifications Deviations from Architectural Drawings ALUM. = ALUMINUM B.O. = BY OTHERS CONT. = CONTINUOUS. = CLEARANCE

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 9/29/2017 Installation Guideline Disclaimer This document contains general installation

More information

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide Flushglaze 4500 For Framed Openings and Horizontal Panels Window System Installation Guide January 2017 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 08/31/2018 Installation Guideline Disclaimer This document contains general installation

More information

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

40mm Thermoclick.  Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) http://www.sundancesupply.com 40mm Thermoclick Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) U-Profile 12' Lengths $39 Out System offers a complete set of extrusions and accessories

More information

FlexLoc. Technical/Installation Information

FlexLoc. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE FLEXLOC PANELS. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE

More information

Shapes Siding. Perfection Shingles. Chalk Line

Shapes Siding. Perfection Shingles. Chalk Line Snap a Chalk Line Shapes Siding Perfection Shingles Chalk Line To establish a straight reference line to guide the positioning of the starter strip and the first course of siding, snap a chalk line. starter

More information

Norwood Windows Permaglass Fiberglass Products Installation Instruction

Norwood Windows Permaglass Fiberglass Products Installation Instruction Norwood Windows Permaglass Fiberglass Products Installation Instruction Care and storage of fiberglass windows: Fiberglass products purchased from Norwood Windows must be stored in a dry sheltered area

More information

BARDOLINE INSTALLATION INSTRUCTIONS

BARDOLINE INSTALLATION INSTRUCTIONS BARDOLINE INSTALLATION INSTRUCTIONS www.onduline.com CONTENTS General conditions Material requirements Terms Estimating shingle requirements Roof preparation Shingle application 9 GENERAL CONDITIONS ONDULINE

More information

Installation Instructions for TruWood Reversible Trim

Installation Instructions for TruWood Reversible Trim Installation Instructions for TruWood Reversible Trim Important: Read and understand all pages of the installation instructions before starting the trim application. For TruWood care and maintenance information,

More information

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February LUX Panel V Groove Installation Installation Guide February 2017 www.luxpanel.ca LUX Panel V Groove Installation LUX panel steel cladding is designed to be installed vertically, horizontally, diagonally

More information

APRON FLASHING NOTES: SHEET METAL APRON FLASHING WITH HEMMED EDGE RAGGLE SEALANT UNDERLAYMENT TURNED UP WALL

APRON FLASHING NOTES: SHEET METAL APRON FLASHING WITH HEMMED EDGE RAGGLE SEALANT UNDERLAYMENT TURNED UP WALL SHEET METAL APRON FLASHING WITH HEMMED EDGE SEALANT SHEET METAL COUNTERFLASHING (SEE NOTE No.1) RAGGLE UNDERLAYMENT TURNED UP WALL SHEET METAL STEP FLASHING SOLDER OR SEAL CORNERS ASPHALT SHINGLES NOTES:

More information

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016 Windows Installed into Walls with Polyiso and Wood Framing Installation Instructions Standard Method Revised 10/24/2016 Background There are many acceptable ways to mount and detail windows for support

More information

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL Window assembly GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS DETAIL TITLE FILE NO. PAGE NO. INTRODUCTION..................................................................

More information

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

Installation Instructions for Standard Lap and Self-Aligning Lap Siding Installation Instructions for Standard Lap and Self-Aligning Lap Siding 7/16 in. Standard Laps Include: All Old Mill Widths, Cedar Shake Lap and Smooth Lap 1/2 in. Self-Aligning Include: 8 in. and 12 in.

More information

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS 2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed

More information

Butyl Flash. Installation Instructions. Prep & General Conditions

Butyl Flash. Installation Instructions. Prep & General Conditions Prep & General Conditions All surfaces must be clean, dust free, smooth and dry. Do not apply over sealants or uncured caulks containing plasticizers or solvents. This includes most silicones and polyurethane

More information

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs. Plank joint 600mm stud crs 600mm 600mm 600mm Horizontal Structural Timber Cavity atten 50x20mm H3.1 atten fixing points 800mm 800mm 300mm 800mm Max. Nog spacing 50mm All intermediate battens to be 50x20mm

More information

Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding

Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding Includes: Cove, Craftsmen Staggered, Diamond, Fish Scale, Octagon, Round and Old Mill Shingle Lap Important: Read and understand

More information

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary. for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) Thank you for selecting JELD -WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows

More information

Ekoroof LiteTile Dimensions

Ekoroof LiteTile Dimensions Ekoroof LiteTile Dimensions 7 3 3.5 Height 40 Width 20 Length Weight per Panel: 3 kg / 6.61 lbs 2 2 Area per panel 800 in / 5.55 ft 2 Panels per Square: 20 (including overlap, for a 100 ft covered area)

More information

Sun Windows General Information New Construction Hinged Door Installation Instructions

Sun Windows General Information New Construction Hinged Door Installation Instructions A G H F H H A. Apply Weather Resistive Barrier B. Apply Bottom Flashing Tape C. Install Sill Pan End Caps & Pan D. Caulk Sides & Top Nailing Surface, Set Door, Fasten E. Apply Side Flashing Tape F. Apply

More information

WALL TO FABRICATED FLOOR

WALL TO FABRICATED FLOOR WALL TO FABRICATED FLOOR PERIMETER WALL IS HELD IN PLACE BY WOODEN STRIP SCREED OPTIONAL NSF COVED FLOOR IS SHOWN PARTITION WALL IS HELD IN PLACE BY WOODEN STRIP SCREED OPTIONAL NSF COVED FLOOR IS SHOWN

More information

Steel Roofing & Siding INSTALLATION GUIDE

Steel Roofing & Siding INSTALLATION GUIDE Steel Roofing & Siding INSTALLATION GUIDE Your Authorized Dealer is: WASHINGTON Auburn (800) 700-7228 WASHINGTON Spokane (866) 321-5954 www.nuraymetals.com CALIFORNIA Redlands (800) 806-8729 CONTENTS BEFORE

More information

Integrity Polygon and Round Top Installation and Finishing Instructions

Integrity Polygon and Round Top Installation and Finishing Instructions Integrity Polygon and Round Top Installation and Finishing Instructions 08/20/2004 70852 BEFORE YOU BEGIN IMPORTANT: Read these instructions thoroughly before beginning to install your Integrity Polygon

More information

CFDTT-01. Control Joint Study (General)

CFDTT-01. Control Joint Study (General) Trim Method Classic Method Notes: Control joints are required and should be located by the designer at the following locations on the construction documents: 144 sf (13.4 sm) is the maximum overall area

More information

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions 14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6

More information

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes General Guidelines These instructions show one type of installation and are intended for the professional

More information

GLOSSARY OF TERMS SECTION 8

GLOSSARY OF TERMS SECTION 8 GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the

More information

DIRECTIONS FOR APPLICATION

DIRECTIONS FOR APPLICATION Instructions 1 General NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE DIRECTIONS

More information

TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION (FASTENER PATTERNS)

TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION (FASTENER PATTERNS) FW SERIES TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION (FASTENER PATTERNS) DETAILS C-1...SIMPLE BASE DETAIL with 1 1/2"

More information

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25 3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25 1 Directions For Applying Malarkey 3-Tab Shingles GENERAL INSTRUCTIONS Install Malarkey 3-tab shingles according to building code and local amendments.

More information

Dear Contractor, I am glad that you are interested in our window rebate program.

Dear Contractor, I am glad that you are interested in our window rebate program. Dear Contractor, I am glad that you are interested in our window rebate program. I have included three documents with this letter. One is our form to indicate your intention to participate in the program.

More information

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Picture Frame Method Revised 10/24/2016

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Picture Frame Method Revised 10/24/2016 Windows Installed into Walls with Polyiso and Wood Framing Installation Instructions Picture Frame Method Revised 10/24/2016 Background There are many acceptable ways to mount and detail windows for support

More information

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows with nailing fin or primed wood windows with exterior trim. While the

More information

Polytegola N. Bitumen Roof shingles. Application guide

Polytegola N. Bitumen Roof shingles. Application guide Polytegola N Bitumen Roof shingles Application guide Application manual POLYTEGOLA N CONTENT 1. Foreword - General conditions 3 2. POLYTEGOLA N designs 4 3. Roof pitches 5 4. Storage 5 5. Roof decking

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions

More information

Table of Contents Light Gauge Metal Roof & Wall Panels

Table of Contents Light Gauge Metal Roof & Wall Panels Table of Contents Light Gauge Metal Roof & Wall Panels Installation Guide for Delta Rib, Nor-Clad, Strata Rib & 2-1/2 Corrugated Introduction Important Notice Notes: April 2008 Minimum Recommended Tools

More information

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION TOOLS AND SUPPLIES 1 TOOLS CHECK LIST 1. laser level 2. hammer 3. pry bars 4. ladders 5. utility knife 6. screw gun 7. applicator foam gun 8. "j"

More information

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11 INSTALLATION MANUAL CONTENTS Important Notes... 2-4 Weather Protective Barriers... 2 Storage and Transportation... 2 Tools and Equipment... 2 Fastener Choices... 3 Wall Preparation... 3,4 Flashing... 4

More information

Pocket Door Installation Instructions

Pocket Door Installation Instructions Installation Instructions Before getting started: Read instructions thoroughly. Be sure that you have the necessary tools and materials before starting the installation. Consult your local building code

More information

ALPINE TRAY. To get the best from this product please follow these recommendations.

ALPINE TRAY. To get the best from this product please follow these recommendations. F I X I N G D E TA I L S ALPINE TRAY The standing seam roofing profile is designed to withstand some of New Zealand s harshest weather in our toughest environments. To get the best from this product please

More information

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

F-WAVE REVIA SYNTHETIC ROOFING SHINGLES

F-WAVE REVIA SYNTHETIC ROOFING SHINGLES F-WAVE REVIA SYNTHETIC ROOFING SHINGLES Installation Manual for Steep-Slope Residential Installations For support with all other Steep-Slope Installations, please call F-Wave Technical Support at 888-GO-FWAVE.

More information

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA TRS 9 35MM 78MM 150MM 78MM THICKNESS END SPAN INTERNAL SPAN MINIMUM PITCH 0.55MM 2.30M 3.20M 3 DESCRIPTION TRS 9 profile is designed for commercial and industrial roofing. The profile is suitable for low

More information

Installation Instructions for Panel Siding and Soffit

Installation Instructions for Panel Siding and Soffit Installation Instructions for Panel Siding and Soffit 7/16 in. Panels Include: Sturdy Panel, Square Edge, 3/4 in. Channel and Reverse Board and Batten (RB&B) 1/2 in. Panels Include: Adobe Shiplap and 808

More information

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3 45 45 6 6 Step 1. Modify Weather Resistive Barrier 1.A Cut the weather resistive barrier flush to the recessed opening (per diagram). Remove the cut away weather resistive barrier, exposing recessed opening

More information

SmartVent Eave Edge Installation Instructions

SmartVent Eave Edge Installation Instructions SmartVent Eave Edge Installation Instructions STEP 1: Cut a slit 1 wide (or a series of 1 ¾ holes at 3 on center) into the roof decking 6 to 7 up from the drip edge. SmartVent is rated 9NFA. Ensure drip

More information

SLATE & SHINGLE INSTALLATION

SLATE & SHINGLE INSTALLATION EAVE EDGE Apply a small strip of roofing paper to the bottom of eave. Eave flashing is attached to substrate with roofing nails every 9". Install underlayment over entire roof. (See Fig. 1) PAGE 1 Bend

More information

DETAIL CROFT FARM OUTBUILDING RESTORATION TOWNSHIP OF CHERRY HILL, NEW JERSEY

DETAIL CROFT FARM OUTBUILDING RESTORATION TOWNSHIP OF CHERRY HILL, NEW JERSEY 2x DIMENSIONAL LUMBER SISTER/SCAB REINFORCEMENT MEMBER 060523 3/8" A304 BOLT @ 8" O.C., STAGGERED EXISTING FRAMING MEMBER SECTION PROVIDE MIN EDGE DISTANCES AS SHOWN, TYP. ELEVATION REFER TO IFICATION

More information

INSTALLATION MANUAL. ZIP System Roof & Wall Sheathing FASTER. TIGHTER. ENERGY EFFICIENT.

INSTALLATION MANUAL. ZIP System Roof & Wall Sheathing FASTER. TIGHTER. ENERGY EFFICIENT. FASTER. TIGHTER. ENERGY EFFICIENT. FROM THE CREATORS OF ZIP System Roof & Wall Sheathing INSTALLATION MANUAL Sales Office: 10925 David Taylor Dr., Suite 300 Phone: 800-933-9220 zipsystem.com Charlotte,

More information

Building Wrap and Flashing

Building Wrap and Flashing Insulati o n Fifth Revision January 2019 Building Wrap and Flashing INSTALLATION GUIDE FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATIONS 1. General Information 2. Usage & Limitations MAX, HPW, VW, RainDrop

More information

METAL ROOFING INSTALLATION GUIDE

METAL ROOFING INSTALLATION GUIDE METAL ROOFING INSTALLATION GUIDE STANDING SEAM ROOFING PANELS Horizon 16 and Climaguard 16 Regardless of whether your roofing project is a new installation or a re-roof, and whether your building is residential,

More information

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

Sun Windows General Information New Construction Sliding Door Installation Instructions H F A G B D C H F H E H A. Apply Weather Resistive Barrier B. Apply Bottom Flashing Tape C. Install Sill Pan End Caps & Pan D. Caulk Sides & Top Nailing Surface, Set Door, Fasten E. Apply Side Flashing Tape

More information