Radiation Protection and On-Site Inspection of the Elevated Subway Construction with an Ir-192 Gamma-Source

Size: px
Start display at page:

Download "Radiation Protection and On-Site Inspection of the Elevated Subway Construction with an Ir-192 Gamma-Source"

Transcription

1 Radiation Protection and On-Site Inspection of the Elevated Subway Construction with an Ir-192 Gamma-Source Bernhard Redmer, Stefan Hohendorf, Falk Hille BAM Berlin

2 Abstract To proof the integrity of riveted steel structures of truss bridges, various non-destructive testing methods can be used. Together with the department Safety of Structures of the BAM Berlin a testing procedure was developed in which the gusset plates were examined radiographically at selected test positions of a bridge construction of the Berlin elevated subway line U1. The inspection was performed during the night break of train traffic. A special service locomotive was ordered to specific bridge positions to generate pre-calculated load pattern to the construction. The load distribution supported the opening of potential radial cracks in the riveted gusset plates. The gamma radiographic inspection was successfully chosen to search for possible fatigue cracks. A gamma source, Irimium-192, with an activity of approx GBq and different digital detectors, such as a digital detector array and imaging plates, were used. The bridge construction was located in regions with residential and commercial buildings. This had to be considered as well as the vehicle and pedestrian traffic to fulfil the radiation protection requirements. The article describes the preparation and performance of the on-site inspection with a gamma source from the technical perspective of radiation protection. In accordance with the German standard DIN part 1 and some basic mathematical calculations for the control area boundary were calculated and compared with locally measured dose rate values. The results were in good agreement with the measurements.

3 Outlines Motivation and Initial Situation Description of the on-site situation Dose calculations for on-site use and comparison Experiences of on-site examinations Summary References The cited map (in parts) is taken: data from OpenStreetMap published under ODbL

4 Motivation Riveted steel truss girder viaduct of the elevated metro line U1 in Berlin-Kreuzberg. Start of operation: 1902, forced break in operation between 1961 und 1995 for reasons of Berlins division. Verification of the structures safety against fatigue failure for the coming 30 years.

5 Preliminary proof testing of fatigue resistance Bridge load tests for identifying the structural system. Laboratory tests at a removed truss girder. Analytical assessment of fatigue resistance. Laboratory tests Determination of critical structural parts regarding fatigue failure critical are gusset plates, hidden by u-shaped girders, testing of radiographic methods for periodic inspections.

6 Concept for periodic inspections with radiography Ca. 400 gusset plates selection of particular critical gusset plates. Decisive selection criteria were: cross sectional weakening in the tensile section of the gusset plate because of structural design, number of rivets or rivet shank diameter, existent or assumed damaging of the gusset plate, detectible by visible deformation, hairline cracks in the coat of paint, corrosion and repair welding.

7 Initial situation from the perspective of test procedure RT is an applicable volume test procedure UT is not possible, due to a) the multi-layer rivet connection: air between the sheets metal and b) the coupling of the test probe is complicated by the application of corrosion-protection paint Wall thickness: mm (single wall), steel RT with Iridium-192 and film / image plates / digital detector array Security and observation of the Ir192-container Work carried out on scaffolding and platforms, in approx. 4 m height Initial situation from the perspective of radiation protection Intended test time: during the service break of U1: between 0:30 and 3:30 o clock; setting up at the test position before; Lively street life (even at night); Buildings: on both sides of the location of examination; lower level: trade, small firms; upper level: living area Discotheques: (unpredictable) public traffic (cars, pedestrians); taxis in stand-by (despite no stopping sign!) Road closure: application to the district office required

8 Situation at the location of examination Parkanlage Parkanlage

9 Situation at the location of examination View to the subway-stop Schlesisiches Tor View to the Oberbaumbrücke... vehicles- and individual traffic... setting up at the test position

10 Parameters for calculations Iridium 192, Activity: 2220 GBq (October 2013) Test sample: t=36 mm, Steel (HVL: 14 mm) Collimator: t=25 mm, Tungsten (HVL:2,5 mm) Boundary of the controlled area: 40 µsv/h Calculations acc. to DIN , Annex 1 Diagram gives the boundary of the controlled area for useful radiation 95 for 2,22*10 12 Bq: a I =95 m for test sample 2,6 HVL Fe : a II =0,45*95 m= 43 m for collimator 10 HVL W : a III =0,05 * 95 m= 4,7 m 2,2*10 12

11 Calculations Radiation protection acc. to education/training guide of the DGZfP * A with : F * H K Ir192 a K, N A 2220GBq, H Ir192 K msv * m² h * GBq 40 µsv h Controlled area (CA)- demarcation at useful radiation attenuated radiation through the sample attenuated radiation through the collimator F F F N N N 1 5, a KI = 97 m a KII = 40 m a KIII = 3 m

12 Demarcation at the location of examination... Parkanlage Fernbedienung Parkanlage Demarcation of the controlled area Workers for the oberservation/monitoring Test site, radiation direction

13 Calculations Application of the passage dose (pedestrian, drivers) Radiation source Ir-192, A= 2220 GBq (October 2013) Dose rate constant: Equation Ir192* A* H v * a with Consideration in direction of the radiation: 0 msv * m² h * GBq Ir192 vehicle Distance test site - roadway: Velocity in average: Dose per passage: a 0 = 5 m v = 30 km/h = m/h H = 8,0 µsv pedestrian distance test site (middle) pedestrian way: a 0 = 15 m Velocity in average: v = 3 km/h = m/h Dose per passage: H = 27 µsv 1. Application of the passage dose must be allowed by the responsible regional authorities. 2. Demarcation could be optimized.

14 Necessary demarcation at the location of examination... Parkanlage Fernbedienung Parkanlage Demarcation of the controlled area Workers for observation/monitoring Test site, radiation direction Free traffic (Pedestrians, vehicle) higher number of trained employees (restricted areas, areas to be supervised) Use of dose rate meter or alarm monitor Technical means (walkie-talkies) Safety through resolute appearance (demarcation, to redirect individual traffic, information etc.) Supervision of the equipment (remote control, container, test site)

15 Structure xy South Axis xy upper position Direction of view: south north Direction of radiation: south sorth Rivet 2: Volume and linear indication under the rivet head: scratch or suspicion of crack?? Iridium 192; DDA: Vidisco (145µm) SDD=80 cm; 20s/f: 320 sec Image is highpass-filtered (EnhanceDetails).

16 Structure xy South Axis xy upper position Direction of view: south north Direction of radiation: south north Rivet 1: Crack in the gusset plate connection at the vertical strut Iridium 192; DDA: Vidisco (145µm) SDD=80 cm; 20s/f: 320 sec Image is highpass-filtered (EnhanceDetails).

17 Measurements of the dose rate, on site 42 µsv/h Parkanlage 80 µsv/h Fernbedienung 81 µsv/h Parkanlage 50 µsv/h Boundary of controlled area Measuring point Location of examination, Direction of radiation

18 Comparison of the calculations and measured values Demarcation at Acc. to DIN Acc. to equation Measured value, on-site Useful radiation 95 m 97 m --- Attenuated radiation (test object) 43 m 40 m (m) µsv/h µsv/h Attenuated radiation (the collimator) 4,7 m 3 m (m) 11 42µSv/h 1. Distance values between standard/equation: The factors a II and a III are rounded up. Regarding to the DIN the determined distance values are greater. conservative approach 1. Attenuated radiation behind the collimator: The measured distance value is a factor 2-3 greater than the calculated values. Possible cause: Scatter radiation through the test object. Corrective actions: additional shielding with lead balls in sacks at the collimator or lead plates behind the test object

19 Modified demarcation at the location of examination µsv/h Parkanlage 80 µsv/h Fernbedienung 81 µsv/h Parkanlage 50 µsv/h Boundary of controlled area Measuring point Location of examination, Direction of radiation Individual and vehicle traffic

20 Summary Based on DIN , annex 1, the determination of the control area delimitation gives a good overview for the practice. The DIN is a practical tool for on-site use. The distance values obtained from the DIN are "conservative" values and are consistent with the "mathematical calculations". For the attenuated radiation the distance values behind the collimator are greater by a factor of 2-3 than the calculated distance values. The application of passage dose is an effective way to minimize the restrictions on individual and vehicle traffic. The implementation of measures for radiation protection requires always personnel and technical resources depending on the situation. Sometimes, the "use of resources" shall to expand greatly.. Increasing efforts are required for security and monitoring of the control area with complicated local conditions. The employees must be trained und instructed in the handling of the technical equipment. They need knowledge of about the specific situation on-site and skills to react in case of unexpected occurrences.

DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER

DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER 14.03.2016 DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS Bernhard REDMER Digital Technology and Networking Imaging Plates Scanner for Imaging Plates Data Transmission Reporting Computed Radiography

More information

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Film Replacement in Radiographic Weld Inspection The New ISO Standard BAM Berlin Film Replacement in Radiographic Weld Inspection The New ISO Standard 17636-2 Uwe Ewert, Uwe Zscherpel, Mirko Jechow Requests and information to: uwez@bam.de 1 Outline - The 3 essential parameters

More information

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16394 A COMPARATIVE STUDY ON THE PERFORMANCE

More information

Pre Conference Workshop on Advanced Digital imaging

Pre Conference Workshop on Advanced Digital imaging Pre Conference Workshop on Advanced Digital imaging Uwe Zscherpel, uwez@bam.de BAM Federal Institute for Materials Research and Testing, Division 8.3 Radiological Methods, Berlin, Germany 1 Content: 1.

More information

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams ECNDT 2006 - We.3.2.3 Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams Bernhard REDMER, Uwe EWERT Federal Institute of Materials Research and Testing (BAM),

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés

More information

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations uwe.ewert@bam.de Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations Uwe Ewert and Uwe Zscherpel BAM Federal Institute for

More information

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography 7 th European-American Workshop on Reliability of NDE Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography Uwe EWERT, Uwe ZSCHERPEL, Justus VOGEL, Fangzhou ZHANG

More information

Part 3: Image quality classes

Part 3: Image quality classes INTERNATIONAL STANDARD ISO 19232-3 Second edition 2013-06-15 Non-destructive testing Image quality of radiographs Part 3: Image quality classes Essais non destructifs Qualité d image des radiogrammes Partie

More information

Ensuring Shielding adequacy in Lead shielded spent fuel transportation casks using gamma scanning

Ensuring Shielding adequacy in Lead shielded spent fuel transportation casks using gamma scanning Ensuring Shielding adequacy in Lead shielded spent fuel transportation casks using gamma scanning More info about this article: http://www.ndt.net/?id=21208 M.Ravichandra 1, P.Raghavendra 1, Dhiren Kothari

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés

More information

Radiometric Measurement Source Container QG 020/100

Radiometric Measurement Source Container QG 020/100 Technical Information TI 94F/00/en Radiometric Measurement Source Container QG 00/00 Operating Instructions 077-000 Designs conforming to chemical industry, European and Swedish standards With rotating

More information

Digital Profile Radiography Practical uses and limitations

Digital Profile Radiography Practical uses and limitations Digital Profile Radiography Practical uses and limitations Mr. Neil Young Asset Reliability Inspections Bunbury, Australia www.ari.com.au neil.young@ari.com.au Introduction Profile digital radiography

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors INTERNATIONAL STANDARD ISO 17636-2 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors Contrôle non destructif des

More information

Fig.2: Scanner VistaScan for image plates

Fig.2: Scanner VistaScan for image plates RADIOGRAPHIC INSPECTION OF WELDINGS BY DIGITAL SENSORS H. Thiele, H.-J. Friemel RADIS GmbH, Johanniskirchen, Germany Abstract: The newly available digital sensors for radiographic inspection are suitable

More information

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES Davi F. OLIVEIRA, Edson V. MOREIRA, Aline S. S. SILVA, José M. B. RABELLO, Ricardo T. LOPES, Marcelo S. PEREIRA, Uwe ZSCHERPEL

More information

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by SPECIFICATION Kilovoltage X-ray Prepared by Igor Gomola, Technical Officer, Project ECU6023, Date 2015-Oct-06 Revision Date Status Comments 0.1 2015-Oct-06 Draft Igor Gomola Page 1 of 12 1. Scope This

More information

Advancements In Digital Radiography: CR, DR, and DICONDE

Advancements In Digital Radiography: CR, DR, and DICONDE Advancements In Digital Radiography: CR, DR, and DICONDE Leo BOIY and Rick CUSCINO, GE Sensing & Inspection Technologies, Berchem, Belgium and Lewistown, USA Introduction Imaging in today s digital age

More information

The HOIS recommended practice for in-service computed radiography of pipes

The HOIS recommended practice for in-service computed radiography of pipes 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa The HOIS recommended practice for in-service computed radiography of pipes Stephen F. BURCH, ESR Technology Ltd 16

More information

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices Moving from film to digital: A study of digital x-ray benefits, challenges and best practices H.U. Pöhler 1 and N. D Ademo 2 DÜRR NDT GmbH & Co. KG, Höpfigheimer Straße 22, Bietigheim-Bissingen, 74321,

More information

Gamex Lite 3.0 Program description and operating manual

Gamex Lite 3.0 Program description and operating manual Gamex Lite 3.0 Program description and operating manual Issue No. : 3.0 Date of Issue : 12-2013 Z.U.T. NDT SOFT http://www.ndtsoft.eu Copyright (c) 2013 by Z.U.T. NDT SOFT All Rights Reserved Disclaimer

More information

New Dose Limits for the Lens of the Eye Implications and Implementation Industrial Radiography

New Dose Limits for the Lens of the Eye Implications and Implementation Industrial Radiography New Dose Limits for the Lens of the Eye Implications and Implementation Industrial Radiography ISEMIR WGIR Richard VAN SONSBEEK 1, John C. LE HERON 2, Gonzague ABELA 3, Francisco C.A. DA SILVA 4, Razak

More information

Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2

Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2 More Info at Open Access Database www.ndt.net/?id=15156 Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2 1 GE Inspection Technologies,

More information

LA DOTD s Nighttime Standards for Construction Operations. Presented by: Tom Ervin Traffic Solutions, Inc.

LA DOTD s Nighttime Standards for Construction Operations. Presented by: Tom Ervin Traffic Solutions, Inc. LA DOTD s Nighttime Standards for Construction Operations Presented by: Tom Ervin Traffic Solutions, Inc. NIGHTTIME CONSTRUCTION OPERATIONS (02/06) NIGHTTIME CONSTRUCTION OPERATIONS (02/06): Section 105,

More information

Fumiaki UEHAN, Dr.. Eng. Senior Researcher, Structural Mechanics Laboratory, Railway Dynamics Div.

Fumiaki UEHAN, Dr.. Eng. Senior Researcher, Structural Mechanics Laboratory, Railway Dynamics Div. PAPER Development of the Non-contact Vibration Measuring System for Diagnosis of Railway Structures Fumiaki UEHAN, Dr.. Eng. Senior Researcher, Structural Mechanics Laboratory, Railway Dynamics Div. This

More information

Digital Profile Radiography Practical uses and limitations

Digital Profile Radiography Practical uses and limitations More info ab Digital Profile Radiography Practical uses and limitations Mr. Neil Young Asset Reliability Inspections Bunbury, Australia www.ari.com.au neil.young@ari.com.au Introduction Profile digital

More information

Advanced Digital Radiography for Field NDT

Advanced Digital Radiography for Field NDT International Symposium on Digital Industrial Radiology and Computed Tomography - We.2.3 Advanced Digital Radiography for Field NDT Ron PINCU, Ofra KLEINBERGER-RIEDRICH Vidisco Ltd. 32 Haharoshet Street,

More information

Performance evaluation of a photon counting detector for high energy NDT applications

Performance evaluation of a photon counting detector for high energy NDT applications Performance evaluation of a photon counting detector for high energy NDT applications More info about this article: http://www.ndt.net/?id=22842 Abstract Angela Peterzol 1, Pascal Brun 1, Charlotte Eriksson

More information

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS 19 th World Conference on Non-Destructive Testing 2016 NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS Brian S. WHITE 1 1 Carestream NDT, 1049 Ridge Road West, Rochester,

More information

Real Time Linear Array Imaging. Brian Caccamise

Real Time Linear Array Imaging. Brian Caccamise Real Time Linear Array Imaging Brian Caccamise 1 Real Time Linear Array Imaging What is Real Time Linear Array Imaging? Or Real Time Radiography (RTR)? 2 Real Time Linear Array Imaging It s Not This! Shoe

More information

Digital Radiology with Photon Counting Detectors

Digital Radiology with Photon Counting Detectors 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Digital Radiology with Photon Counting Detectors More Info at Open Access Database www.ndt.net/?id=16709

More information

Digital Radiography and its Advantages in Field NDT Inspections Today

Digital Radiography and its Advantages in Field NDT Inspections Today 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Digital Radiography and its Advantages in Field NDT Inspections Today Ron PINCU NDT Division Manager, Vidisco Ltd. 32 Haharoshet

More information

Minnesota Rules, Chapter 4732 X-ray Revision

Minnesota Rules, Chapter 4732 X-ray Revision Minnesota Rules, Chapter 4732 X-ray Revision DRAFT INDUSTRIAL X-RAY SYSTEMS DEFINTIONS, 1.0 4732.####. INDUSTRIAL X-RAY SYSTEMS DEFINITIONS. Subpart 1. Scope. For purposes of industrial x-ray systems under

More information

NON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I

NON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I NON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I 1.What do you mean by Non-Destructive Testing (NDT)? Inspecting or testing the materials and components in such a way that allows the materials

More information

Computed Radiography

Computed Radiography BAM Berlin Computed Radiography --INDE 2007, Kalpakkam, India -- Uwe Zscherpel, Uwe Ewert BAM Berlin, Division VIII.3 Requests Requests and and information information to: to: Dr. Dr. U. U. Zscherpel Zscherpel

More information

A Modified Detectability Criterion for Conventional Radiography Simulation

A Modified Detectability Criterion for Conventional Radiography Simulation 19 th World Conference on Non-Destructive Testing 2016 A Modified Detectability Criterion for Conventional Radiography Simulation David TISSEUR 1, Caroline VIENNE 1, Pierre GUÉRIN 2, Angela PETERZOL PARMENTIER

More information

Car-park barriers, 500 mm above ground, flexible

Car-park barriers, 500 mm above ground, flexible Car-park barriers, 500 mm above ground, flexible Crash-proof barrier post Flexible to impact and thrust Above ground 500 mm Pass-over height approx. 95 mm Flexible! Crash-proof! 40215UZB approx.kg Part-No.

More information

INTERNAL CONCRETE INSPECTION AND EVALUATION METHODS FOR STEEL PLATE-BONDED SLABS BY USING ELASTIC WAVES VIA ANCHOR BOLTS

INTERNAL CONCRETE INSPECTION AND EVALUATION METHODS FOR STEEL PLATE-BONDED SLABS BY USING ELASTIC WAVES VIA ANCHOR BOLTS More info about this article: h Czech Society for Nondestructive Testing 32 nd European Conference on Acoustic Emission Testing Prague, Czech Republic, September 7-9, 216 INTERNAL CONCRETE INSPECTION AND

More information

Diagnostic X-Ray Shielding

Diagnostic X-Ray Shielding Diagnostic X-Ray Shielding Multi-Slice CT Scanners Using NCRP 147 Methodology Melissa C. Martin, M.S., FAAPM, FACR Therapy Physics Inc., Bellflower, CA AAPM Annual Meeting, Orlando, FL FL Refresher Course

More information

Gamex CR 2.0 Program description and operating manual

Gamex CR 2.0 Program description and operating manual Gamex CR 2.0 Program description and operating manual Issue No. : 2.0 Date of Issue : Jan. 2013 Z.U.T. NDT SOFT http://www.ndtsoft.eu Copyright (c) 2013 by Z.U.T. NDT SOFT All Rights Reserved Disclaimer

More information

Radiographic testing: Increased detection sensitivity using optimum source to object distance

Radiographic testing: Increased detection sensitivity using optimum source to object distance 18 th World Conference on Non destructive Testing, 16-20 April 2012, Durban, South Africa Radiographic testing: Increased detection sensitivity using optimum source to object distance Jan Hendrik COWAN

More information

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology Uwe EWERT, Uwe ZSCHERPEL, Mirko

More information

European Technical Assessment ETA-04/0038 English translation prepared by DIBt. Page 2 of July 2016

European Technical Assessment ETA-04/0038 English translation prepared by DIBt. Page 2 of July 2016 European Technical Assessment ETA-04/0038 Page 2 of 15 29 July 2016 The European Technical Assessment is issued by the Technical Assessment Body in its official language. Translations of this European

More information

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions More information using less radiation Medical Small Animal Security NDE/NDT Diffraction-Enhanced X-ray Imaging Medical Solutions Safe non-invasive

More information

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012 The HOIS recommended practice for in-service computed radiography of pipes WCNDT 2012, Durban, SA. April 2012 Dr Stephen F Burch, ESR Technology, Oxfordshire,UK steve.burch@esrtechnology.com ESR Technology

More information

Welding Inspection Non-Destructive Testing Course Reference WIS 5

Welding Inspection Non-Destructive Testing Course Reference WIS 5 Welding Inspection Non-Destructive Testing Course Reference WIS 5 Non Destructive Testing A welding inspector should have a working knowledge of NDT methods and their applications, advantages and disadvantages.

More information

Engineering Policy & Procedure

Engineering Policy & Procedure FPD > Engineering > Global Standards Engineering Policy & Procedure Revision History Number: G2-4 Section: G Subject: Radiographic Examination Procedure 1.0 SCOPE This procedure specifies the requirements

More information

ScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)

ScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR) Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 69 ( 2014 ) 1216 1224 24th DAAAM International Symposium on Intelligent Manufacturing and Automation, 2013 Evaluation of Pipe

More information

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY 19 th World Conference on Non-Destructive Testing 2016 PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY Steven MANGO 1 1 Carestream

More information

Paper Title: FIELD MONITORING OF FATIGUE CRACK ON HIGHWAY STEEL I- GIRDER BRIDGE

Paper Title: FIELD MONITORING OF FATIGUE CRACK ON HIGHWAY STEEL I- GIRDER BRIDGE Zhang, Zhou, Fu and Zhou Paper Title: FIELD MONITORING OF FATIGUE CRACK ON HIGHWAY STEEL I- GIRDER BRIDGE Author: Author: Author: Author: Call Title: Yunfeng Zhang, Ph.D. Associate Professor Department

More information

ON THE WAY TO DIGITAL RADIOGRAPHY

ON THE WAY TO DIGITAL RADIOGRAPHY The 14 th International Conference of the Slovenian Society for Non-Destructive Testing»Application of Contemporary Non-Destructive Testing in Engineering«September 4-6, 2017, Bernardin, Slovenia More

More information

SSPC-PA 2 Procedure for Determining Conformance to Dry Coating Thickness Requirements

SSPC-PA 2 Procedure for Determining Conformance to Dry Coating Thickness Requirements SSPC-PA 2 Procedure for Determining Conformance to Dry Coating Thickness Requirements William D. Corbett, KTA-Tator, Inc. Chair SSPC Committee C.3.2 on Dry Film Thickness Measurement SSPC-PA 2 Procedure

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 16371-1 First edition 2011-10-01 Non-destructive testing Industrial computed radiography with storage phosphor imaging plates Part 1: Classification of systems Essais non destructifs

More information

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

Digital Radiographic Inspection replacing traditional RT and 3D RT Development Digital Radiographic Inspection replacing traditional RT and 3D RT Development Iploca Novel Construction Meeting 27&28 March 2014 Geneva By Jan van der Ent Technical Authority International Contents Introduction

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded INTERNATIONAL STANDARD ISO 17636 First edition 2003-09-15 Non-destructive testing of welds Radiographic testing of fusionwelded joints Contrôle non destructif des assemblages soudés Contrôle par radiographie

More information

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales Spokane Industries Computed Radiography Implementation Experience David Jolin Technical Sales djolin@spokaneindustries.com Outline Background Our Decision for Computed Radiography Implementation of CR

More information

TABLE OF CONTENTS. References

TABLE OF CONTENTS. References ANALYTICAL X-RAY EQUIPMENT USE POLICIES & PROCEDURES Page 1 of 9 Revised: 11/24/2003 TABLE OF CONTENTS 1.0 General 2.0 Purpose 3.0 Scope and Authority 4.0 Equipment Requirements 4.0.1 Safety device 4.0.2

More information

Introduction To NDT. BY: Omid HEIDARY

Introduction To NDT. BY: Omid HEIDARY Introduction To NDT BY: Omid HEIDARY NDT Methods Penetrant Testing Magnetic Particle Testing Eddy Current Testing Ultrasonic Testing Radiographic Testing Acoustic Emission Infrared Testing Visual Testing

More information

digital radiography r High-energy DT Applications lior Pick, Ron Pincu and Ofra Kleinberger over film radiog- p P This advanced

digital radiography r High-energy DT Applications lior Pick, Ron Pincu and Ofra Kleinberger over film radiog- p P This advanced igital Radiography r High-energy DT Applications lior Pick, Ron Pincu and Ofra Kleinberger p P ortable digital radiography has gained popularity raphy and film replacements process-free films) by providing

More information

Radiological Safety Analysis Document for the CLAS12 Engineering and the first physics run of Run Group A

Radiological Safety Analysis Document for the CLAS12 Engineering and the first physics run of Run Group A Radiological Safety Analysis Document for the CLAS12 Engineering and the first physics run of Run Group A This Radiological Safety Analysis Document (RSAD) will identify the general conditions associated

More information

ipix Gamma Imager Product Introduction Steve Laskos Product Management Director

ipix Gamma Imager Product Introduction Steve Laskos Product Management Director ipix Gamma Imager Product Introduction Steve Laskos Product Management Director ipix: The Next Generation Gamma Imaging System ipix the new generation of gamma camera Simple, easy to use for experts and

More information

KÜNDIG CONTROL SYSTEMS The Gauge Manufacturer for Film Extrusion SWISS MADE. K-NDC Rotomat KT. Nuclear thickness gauge for barrier films

KÜNDIG CONTROL SYSTEMS The Gauge Manufacturer for Film Extrusion SWISS MADE. K-NDC Rotomat KT. Nuclear thickness gauge for barrier films K-NDC Rotomat KT KÜNDIG CONTROL SYSTEMS Nuclear thickness gauge for barrier films K-NDC Rotomat KT The K-NDC Rotomat KT is a thickness measuring system for blown film lines and measures online the thickness

More information

Application Note. ipix A Gamma imager to support various applications. Introduction. An easy to carry and deploy instrument

Application Note. ipix A Gamma imager to support various applications. Introduction. An easy to carry and deploy instrument Application Note ipix A Gamma imager to support various applications Introduction ipix is a unique gamma imager that quickly locates low level radioactive sources from a distance and estimates the dose

More information

SSPC-PA 2 Procedure for Determining Conformance to Dry Coating Thickness Requirements

SSPC-PA 2 Procedure for Determining Conformance to Dry Coating Thickness Requirements SSPC-PA 2 Procedure for Determining Conformance to Dry Coating Thickness Requirements William D. Corbett, KTA-Tator, Inc. Chair SSPC Committee C.3.2 on Dry Film Thickness Measurement SSPC-PA 2 Procedure

More information

Projection Radiography. application on stream

Projection Radiography. application on stream Projection Radiography application on stream common research project BASF and BAM, later with AGFA/GE IT, IT, IAEA: computer based radiographic wall wall thickness measurement contents: --basic principles

More information

REPAIR OF NE KRSKO STEAM GENERATOR TUBES BY SLEEVING METHOD

REPAIR OF NE KRSKO STEAM GENERATOR TUBES BY SLEEVING METHOD HR9800122 REPAIR OF NE KRSKO STEAM GENERATOR TUBES BY SLEEVING METHOD Prepared by: Kresimir Gudek, Drago Pete Krsko Nuclear Power Plant, Vrbina 12, 8270 Krsko, Slovenia ABSTRACT In order to decrease the

More information

X-ray backscattering: Variable irradiation geometry facilitates new insights

X-ray backscattering: Variable irradiation geometry facilitates new insights 18 th World Conference of Non Destructive Testing, 16-20 April 2012, Durban, South Africa X-ray backscattering: Variable irradiation geometry facilitates new insights Norma WROBEL 1, Kurt OSTERLOH 1, Mirko

More information

Strategies for Film Replacement in Radiography - a comparative study -

Strategies for Film Replacement in Radiography - a comparative study - IV Conferencia Panamericana de END Buenos Aires Octubre 2007 Strategies for Film Replacement in Radiography - a comparative study - 1 Uwe Ewert, 1 Uwe Zscherpel, 2 Klaus Bavendiek 1 BAM-Berlin, Federal

More information

EDDYCON C AIRCRAFT SET OF EDDY CURRENT FLAW DETECTOR FOR AIRCRAFTS TESTING. CE MARKING

EDDYCON C AIRCRAFT SET OF EDDY CURRENT FLAW DETECTOR FOR AIRCRAFTS TESTING.  CE MARKING AIRCRAFT SET OF EDDY CURRENT FLAW DETECTOR Member company of «OKO ASSOCIATION» Group EDDYCON C FOR AIRCRAFTS TESTING Surface and subsurface defect detection. Assessment of defect depth. Conductivity measurement.

More information

The field deployable digital X-Ray solution for weld inspection in O&G

The field deployable digital X-Ray solution for weld inspection in O&G The field deployable digital X-Ray solution for weld inspection in O&G Imagination at work. Haitham Ibrahim, Hanley Thomas, Steven Wissels 7 th MENDT Conference Bahrain Agenda Field inspection Actual weld

More information

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography ECNDT 26 - Poster 17 Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography Khairul Anuar MOHD SALLEH, Ab. Razak HAMZAH and Mohd Ashhar

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement INTERNATIONAL STANDARD ISO 16809 First edition 2012-11-15 Non-destructive testing Ultrasonic thickness measurement Essais non destructifs Mesurage de l'épaisseur par ultrasons Reference number ISO 2012

More information

High Energy Digital Radiography & 3D-CT for Industrial Systems

High Energy Digital Radiography & 3D-CT for Industrial Systems DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France High Energy Digital Radiography & 3D-CT for Industrial Systems Non-Destructive

More information

FOUR CATEGORIES OF SAFETY

FOUR CATEGORIES OF SAFETY OCTOBER 2013 FOUR CATEGORIES OF SAFETY DOSIMETRY PERSONAL SAFETY EQUIPMENT EQUIPMENT KNOWLEDGE PHYSICAL SAFETY DOSIMETRY THERMAL LUMINISCENT DEVICES AND FILM BADGES CNSC PERMISSIBLE DOSES WHOLE BODY DOSE

More information

Development of 24 GHz-band High Resolution Multi-Mode Radar

Development of 24 GHz-band High Resolution Multi-Mode Radar Special Issue Automobile Electronics Development of 24 GHz-band High Resolution Multi-Mode Radar Daisuke Inoue*, Kei Takahashi*, Hiroyasu Yano*, Noritaka Murofushi*, Sadao Matsushima*, Takashi Iijima*

More information

(a) This subchapter applies to installations using analytical x-ray equipment and establishes requirements for their use.

(a) This subchapter applies to installations using analytical x-ray equipment and establishes requirements for their use. SUBCHAPTER 21. ANALYTICAL X-RAY INSTALLATIONS 7:28-21.1 Scope (a) This subchapter applies to installations using analytical x-ray equipment and establishes requirements for their use. (b) The provisions

More information

Requirements for manufacture of anchors

Requirements for manufacture of anchors W29 (June 2005) Requirements for manufacture of anchors 1. General requirements 1.1 Scope These Rules apply to the materials, manufacture and testing, and certification of anchors, shanks and anchor shackles

More information

RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT

RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT 420-3-26-.11 RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT (1) Purpose and Scope. This rule 420-3-26-.11 provides special requirements for analytical x- ray equipment; provided, however,

More information

Long Range Ultrasonic Testing - Case Studies

Long Range Ultrasonic Testing - Case Studies More info about this article: http://www.ndt.net/?id=21145 Prawin Kumar Sharan 1, Sheethal S 1, Sri Krishna Chaitanya 1, Hari Kishore Maddi 1 1 Sievert India Pvt. Ltd. (A Bureau Veritas Company), 16 &

More information

Experiences of users in Digital Radiography

Experiences of users in Digital Radiography Computed Radiography Products & Applications Experiences of users in Digital Radiography Jimmy Opdekamp May Jimmy 2006Opdekamp Global Product Manager CR Int l Workshop Imaging NDT Chennai, 25-28 April

More information

INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED PLASTIC (CFRP) BY EDDY CURRENT NON- DESTRUCTIVE TESTING

INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED PLASTIC (CFRP) BY EDDY CURRENT NON- DESTRUCTIVE TESTING International Workshop SMART MATERIALS, STRUCTURES & NDT in AEROSPACE Conference NDT in Canada 2011 2-4 November 2011, Montreal, Quebec, Canada INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED

More information

Examination of Pipe Welds by Image Plate Based Computed Radiography System

Examination of Pipe Welds by Image Plate Based Computed Radiography System Examination of Pipe Welds by Image Plate Based Computed Radiography System Sanjoy Das, M.S.Rana, Benny Sebastian, D. Mukherjee and K.K. Abdulla Atomic Fuels Division Bhabha Atomic Research Centre Mumbai

More information

IAEA Coordinated Research Project on Development of Harmonized QA/QC Procedures for Maintenance and Repair of Nuclear Instruments

IAEA Coordinated Research Project on Development of Harmonized QA/QC Procedures for Maintenance and Repair of Nuclear Instruments PROCEDURE: TEST PROCEDURE FOR GEIGER-MUELLER RADIATION DETECTORS Nº: MRNI-501 DECEMBER 2008 PAGE: 1 OF: 17 IAEA Coordinated Research Project on Development of Harmonized QA/QC Procedures for Maintenance

More information

WALCOOM. Walcoom Corporation GARRISON FENCE.

WALCOOM. Walcoom Corporation GARRISON FENCE. WALCOOM Walcoom Corporation "Galvanized steel picket fence with absolute advantage over the wrought iron & stainless steel fence." Walcoom is a professional metal fencing manufacturer. We always adhere

More information

Table 1 The wheel-set security system of China high-speed railway

Table 1 The wheel-set security system of China high-speed railway 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16352 Dynamic ultrasonic inspection technology

More information

Study on Spectrum of Acoustic Emission Signals of Bridge Crane

Study on Spectrum of Acoustic Emission Signals of Bridge Crane Study on Spectrum of Acoustic Emission Signals of Bridge Crane Gongtian SHEN, Zhanwen WU China Special Equipment Inspection Institute, Beijing 100013, China Tel: +86-10-59068008, Fax: +86-10-59068023 E-mail:

More information

Nuclear Associates , &

Nuclear Associates , & Nuclear Associates 76-810, 76-814 76-815 & 76-818 Bar Phantoms and Test Patterns Operators Manual March 2005 Manual No. 76-810-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A.

More information

PRELIMINARY. The following table outlines the specifications of our standard tunable 2D-mirror MR Custom mirror coatings are possible.

PRELIMINARY. The following table outlines the specifications of our standard tunable 2D-mirror MR Custom mirror coatings are possible. Datasheet: MR-1-3 Copyright 212 Optotune Dual axis mirror with position feedback MR-1-3 Optotune s dual axis mirror series MR-1-3 is the ideal choice for applications that require large deflections in

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

Series 1600 WeatherGuard Dock Enclosure

Series 1600 WeatherGuard Dock Enclosure Fairborn USA Inc. 205 Broadview Street Upper Sandusky, OH 43351 1-800-262-1188 Fax 1-419-294-4980 Series 1600 WeatherGuard Dock Enclosure All Models! WARNING Do not install this product unless you read

More information

Y11-DR Digital Radiography (DR) Image Quality

Y11-DR Digital Radiography (DR) Image Quality Y11-DR Digital Radiography (DR) Image Quality Image quality is stressed for all systems in Safety Code 35. In the relevant sections Health Canada s advice is the manufacturer s recommended test procedures

More information

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training Following is an outline of the material covered in the training course. Each person

More information

RIVETING Rivet types Solid rivets Solid rivets are used less and less. They have been replaced in many cases by welding or bonding.

RIVETING Rivet types Solid rivets Solid rivets are used less and less. They have been replaced in many cases by welding or bonding. 10.1 Rivet types 10.1.1 Solid rivets Solid rivets are used less and less. They have been replaced in many cases by welding or bonding. Because of the large countersinking angle of 140 flat countersunk

More information

PORTABLE EDDY CURRENT FLAW DETECTOR VD3-81 EDDYCON

PORTABLE EDDY CURRENT FLAW DETECTOR VD3-81 EDDYCON PORTABLE EDDY CURRENT VD3-81 EDDYCON CE MARKING EN 13860-1 Compliant EN 13860-2 Compliant www.ndt.com.ua 2 PURPOSE ADVANTAGES DISTINCTIVE FEATURES TECHNICAL SPECIFICATION AND SERVICE FUNCTIONS OF THE INSTRUMENT

More information

X-RAYS - NO UNAUTHORISED ENTRY

X-RAYS - NO UNAUTHORISED ENTRY Licencing of premises Premises Refer Guidelines A radiation warning sign and warning notice, X-RAYS - NO UNAUTHORISED ENTRY must be displayed at all entrances leading to the rooms where x-ray units are

More information

Barofor Round System (polyester coated) Panels, Posts, Accessories

Barofor Round System (polyester coated) Panels, Posts, Accessories 1 Scope This Technical Data Sheet specifies the requirements for the Barofor Round System. The complete system exists of: Panels Posts Accessories such as fixation system and posts caps. Panels and posts

More information

Multi-Parameter POD for Industrial Applications The Influence of the Material Attenuation as an Example

Multi-Parameter POD for Industrial Applications The Influence of the Material Attenuation as an Example Seminar des Fachausschusses Ultraschallprüfung - Vortrag 14 Multi-Parameter POD for Industrial Applications The Influence of the Material Attenuation as an Example Mato PAVLOVIC, Rainer BOEHM, Christina

More information

4. Contrast is the. There must The function of contrast is to:. The types of contrast are.

4. Contrast is the. There must The function of contrast is to:. The types of contrast are. RADIOGRAPHIC VISIBILITY OF DETAIL STUDY QUESTIONS 1. What is visibility of detail? It is controlled by properties. What are the two factors that affect it? 2. What is sharpness of detail? It is controlled

More information

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY 12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY Rajashekar

More information

High resolution crack detection on turbine blade roots by the use of eddy current and ultrasonic Rayleigh waves

High resolution crack detection on turbine blade roots by the use of eddy current and ultrasonic Rayleigh waves 19 th World Conference on Non-Destructive Testing 2016 High resolution crack detection on turbine blade roots by the use of eddy current and ultrasonic Rayleigh waves Ernst RAU 1, Joachim BAMBERG 2, Jürgen

More information