Projection Radiography. application on stream
|
|
- Jasmin Wells
- 5 years ago
- Views:
Transcription
1 Projection Radiography application on stream common research project BASF and BAM, later with AGFA/GE IT, IT, IAEA: computer based radiographic wall wall thickness measurement contents: --basic principles --software for forevaluation and and documentation --corrosion depth evaluation --validation of of methods 1
2 Projection Radiography Examples on Corrosion and Erosion Corrosion and Seads Corrosion Erosion 2
3 History: radiographic wall thickness evaluation applied since ca nearly no literature until 1980 growing importance in chemical industry caused by onstream application since 1996 projects BASF und BAM for physical studies standardization open (IAEA Draft) BASF drawing from
4 classical set-up: typical exposure: radiation source, Ir 192 insulation pipe line film, imaging plate, or flat panel profile line 4
5 Projection Radiography Example : distribution station film source on-site exposure, Ir 192 radiograph 5
6 Projection Radiography visual evaluation of wall thickness error sources: w - wrong density range - inaccurate edge detection (unsharpness) - wrong magnification factor 6
7 Principle of projection radiography tangential penetration of pipe wall f - film focus distance r - outer pipe radius R - outer radius of insulation w - wall thickness projection on detector plane pipe insulation w` measured on film 7
8 Projection Radiography PC based wall thickness measurement overview of measurement equipment (BASF at 2000, before CR): RT exposure scanner PC protocol screen/film : film digitisation RCF + F8 (16 bit, 300 dpi) (7% of exposure time of Pb+D7) software for measurement (algorithms) and documentation data base 8
9 Projection Radiography PC based wall thickness measurement film digitisation imaging plate flat panel single program for evalution of all digital images, no size limitation support for all detectors by external 16 bit LUT tables for linearisation (gray value proportional to radiation intensity) 9
10 16 bit software platform wtscope.exe image processing know-how on on Windows PC: (ISee!, see --fully fully16 16 bit bitdata datadepth for forevaluation and and display --unlimited image sizes, limited only onlyby bymain mainmemory (>1 (>1 GByte) --all all detectors (digitized film, film, imaging plates, flat flatpanel detectors) via via external bit bitlookup Tables (LUT) linearizable, ASCII text text -fast - fast rekursive moving average filtering for forarbitrary sizes sizesof of high high and and low lowpass filters, convolution with withvariable kernels (ASCII text) text) --sub-sampling for forimage display with withtrue trueaveraging --error errorestimation for formeasured values and and geometric correction --quick documentation of of measurements by byprotocol generation and and transfer to to Word --protection of of application by byindividual encrypted license keys keys 10
11 Projection Radiography PC based wall thickness measurement input exposure parameters wall thickness result table with measurement regions tangential wall thickness algorithm wall thickness deviation in measurement region 11
12 synchronous display of positions in profile and image! position correction by hand, if algorithm fails! 12
13 Projection Radiography PC generated measurement protocol 13
14 Projection Radiography Algorithms : PC based wall thickness measurement problem: correct detection of wall positions characteristic points, curve fitting, CT reconstr. inner wall of pipe max. outer wall of pipe projected wall thickness w 14
15 Limits of of Tangential Radiography (TRT): L max W L max = 2W sqrt(d a /W 1) 300 kv 200 kv Energy: L max 100 kv : 10 mm 200 kv : 30 mm 300 kv : 40 mm 400 kv : 50 mm Se-75 : 60 mm Ir-192 : 75 mm Co-60 : 120 mm 15
16 Radiographic Evaluation of Corrosion and Deposits in Pipelines: Results of an IAEA Co-ordinated Research Programme Steel pipes up up to to 20 with NDT film and X-ray, Ir-192, Co Algeria Hungary Romania Iran Pakistan Germany Uruguay Syria India Turkey Malaysia Canada 16
17 Fabricated Reference Blocks with Steps and Holes: Iran Idea: explore inspection methods with known wall thicknesses 17
18 18
19 algorithm detects edges, visual not seeable in image : extension of application range in comparison to visual evaluation Ir 192, DN200: 6 11 mm Co 60, DN300: mm 19
20 2005: Validation of of wtscope, CR-Tower and Ir-192 BAM BASF GE IT 20
21 Validation as as measurement method according to to ISO 17025: Steel pipes mm dia, empty, water filled, w/o insulation 21
22 Radiographic Corrosion Inspection Two inspection techniques possible : 2. Corrosion assessment from local film density changes (Double Wall Technique, DWT) 22
23 local corrosion : wall thickness differences in penetration direction (DWT) source pipe erosion w-δw intensity change, ΔI attenuation law: detector I w = I 0 e -µ eff w µ eff - effective attenuation coefficient relative measurement: 1. Calibration: 2. Measurement: 2 step algorithm µ eff = ln ( D REF / D IQI ) / Δw IQI Δw = ln ( D REF / D MEAS ) / µ eff 23
24 DWT for local corrosion 1. Calculation of effective attenuation coefficient µ eff known hole depth signal at measurement point signal at reference point known pipe wall thickness w at reference point Result: µ eff eff = f(w) dep. on on radiation energy and wall thickness differences 24
25 IAEA CRP, film Calculated attenuation coefficient (1/mm) 0,50 0,45 0,40 0,35 0,30 0,25 0,20 0,15 0,10 0,05 0,00 Double wall technique 6" and 8", 100 kv, with and without insulation y = 0,6689x -0,3385 R 2 = 0,7316 y = 0,5039x -0,3927 R 2 = 0, Penetrated steel wall thickness (mm) Iran, Uruguay insulation decreasing µ eff eff with penetrated wall and insulation 25
26 IAEA CRP, film 0,10 0,09 Double wall technique, Ir 192 Ir-192 Calculated attenuation coefficient (1/mm) 0,08 0,07 0,06 0,05 0,04 0,03 0,02 0,01 0,00 Uruguay Iran Uruguay with Insulation Iran with Insulation Penetrated steel wall thickness (mm) % of of all all measurements: µ eff eff = /- +/ mm
27 IAEA CRP, film 0,045 Double wall technique Co-60 Calculated attenuation coefficient [1/mm] 0,040 0,035 0,030 0,025 0,020 0,015 0,010 0,005 0,000 12" pipe 8" pipe mean µeff Penetrated steel wall thickenss [mm] % of of all all measurements: µ eff eff = /- +/ mm
28 Computer based evaluation with withwtscope/isee! software: accuracy mm, mm, µ eff =0.028/mm eff 28
29 Comparison Film // CR DWT with Ir-192: Result of wtscope validation for CR Tower by BAM / BASF / GE IT effective attenuation coefficient [1/mm] 0,06 0,05 0,04 0,03 0,02 0,01 µ eff CR Film reason: scatter sensitivity! pipe wall thickness [mm] 29
30 Projection Radiography Summary program for PC based routine measurements on images from all radiographic detectors, tangential wall thickness measurement and local corrosion, simple documentation wall thickness range enlarged compared with visual evaluation in projection radiography measurement of corrosion depth (in centre of pipe) validation as measurement methods acc. to ISO programs transfered to GE IT for worldwide marketing (Rhythm Version 2 all methods implemented) differences in sensitivity to scattered radiation between film and imaging plates inspection technique not standardised, written practice necessary! standard development has to be started soon 30
31 The End 31
Pre Conference Workshop on Advanced Digital imaging
Pre Conference Workshop on Advanced Digital imaging Uwe Zscherpel, uwez@bam.de BAM Federal Institute for Materials Research and Testing, Division 8.3 Radiological Methods, Berlin, Germany 1 Content: 1.
More informationFilm Replacement in Radiographic Weld Inspection The New ISO Standard
BAM Berlin Film Replacement in Radiographic Weld Inspection The New ISO Standard 17636-2 Uwe Ewert, Uwe Zscherpel, Mirko Jechow Requests and information to: uwez@bam.de 1 Outline - The 3 essential parameters
More informationComputed Radiography
BAM Berlin Computed Radiography --INDE 2007, Kalpakkam, India -- Uwe Zscherpel, Uwe Ewert BAM Berlin, Division VIII.3 Requests Requests and and information information to: to: Dr. Dr. U. U. Zscherpel Zscherpel
More informationFig.2: Scanner VistaScan for image plates
RADIOGRAPHIC INSPECTION OF WELDINGS BY DIGITAL SENSORS H. Thiele, H.-J. Friemel RADIS GmbH, Johanniskirchen, Germany Abstract: The newly available digital sensors for radiographic inspection are suitable
More informationThe HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012
The HOIS recommended practice for in-service computed radiography of pipes WCNDT 2012, Durban, SA. April 2012 Dr Stephen F Burch, ESR Technology, Oxfordshire,UK steve.burch@esrtechnology.com ESR Technology
More informationExperiences of users in Digital Radiography
Computed Radiography Products & Applications Experiences of users in Digital Radiography Jimmy Opdekamp May Jimmy 2006Opdekamp Global Product Manager CR Int l Workshop Imaging NDT Chennai, 25-28 April
More informationThe HOIS recommended practice for in-service computed radiography of pipes
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa The HOIS recommended practice for in-service computed radiography of pipes Stephen F. BURCH, ESR Technology Ltd 16
More information» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique
Recommended Techniques» There are many possible techniques for making good radiographs using CR» Following a defined procedure will simplify technique development and shorten the time to a good image»
More informationOverview. Corrosion detection improvement of oil and gas pipelines with industrial radiography method by using image processing.
detection improvement of oil and gas pipelines with industrial radiography method by using image processing Alireza Karimian (Engineering faculty of Isfahan university, Isfahan,, Iran ) Sepideh Yazdani
More informationScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 69 ( 2014 ) 1216 1224 24th DAAAM International Symposium on Intelligent Manufacturing and Automation, 2013 Evaluation of Pipe
More informationDigital Profile Radiography Practical uses and limitations
Digital Profile Radiography Practical uses and limitations Mr. Neil Young Asset Reliability Inspections Bunbury, Australia www.ari.com.au neil.young@ari.com.au Introduction Profile digital radiography
More informationEssential Parameters and Conditions for Optimum Image Quality in Digital Radiology
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology Uwe EWERT, Uwe ZSCHERPEL, Mirko
More informationMinimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations
uwe.ewert@bam.de Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations Uwe Ewert and Uwe Zscherpel BAM Federal Institute for
More informationDigital Profile Radiography Practical uses and limitations
More info ab Digital Profile Radiography Practical uses and limitations Mr. Neil Young Asset Reliability Inspections Bunbury, Australia www.ari.com.au neil.young@ari.com.au Introduction Profile digital
More informationEssential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography
7 th European-American Workshop on Reliability of NDE Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography Uwe EWERT, Uwe ZSCHERPEL, Justus VOGEL, Fangzhou ZHANG
More informationPERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY
12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY Rajashekar
More informationGamex Lite 3.0 Program description and operating manual
Gamex Lite 3.0 Program description and operating manual Issue No. : 3.0 Date of Issue : 12-2013 Z.U.T. NDT SOFT http://www.ndtsoft.eu Copyright (c) 2013 by Z.U.T. NDT SOFT All Rights Reserved Disclaimer
More informationMoving from film to digital: A study of digital x-ray benefits, challenges and best practices
Moving from film to digital: A study of digital x-ray benefits, challenges and best practices H.U. Pöhler 1 and N. D Ademo 2 DÜRR NDT GmbH & Co. KG, Höpfigheimer Straße 22, Bietigheim-Bissingen, 74321,
More informationTHE CR SPECIALISTS HD-CR CR 35 NDT
THE CR SPECIALISTS HD-CR CR 35 NDT COMPUTED RADIOGRAPHY SYSTEMS Digital Intelligence Ready to Change. www.duerr-ndt.com VERSATILE AND DEPENDABLE HIGH-TECH MADE IN GERMANY Highest resolution DÜRR NDT is
More informationDigital Radiographic Inspection replacing traditional RT and 3D RT Development
Digital Radiographic Inspection replacing traditional RT and 3D RT Development Iploca Novel Construction Meeting 27&28 March 2014 Geneva By Jan van der Ent Technical Authority International Contents Introduction
More informationStrategies for Film Replacement in Radiography - a comparative study -
IV Conferencia Panamericana de END Buenos Aires Octubre 2007 Strategies for Film Replacement in Radiography - a comparative study - 1 Uwe Ewert, 1 Uwe Zscherpel, 2 Klaus Bavendiek 1 BAM-Berlin, Federal
More informationUser manual for the measuring program IC.exe ISee!
User manual for the page 1 of 40 BAM User manual for the measuring program IC.exe ISee! This software allows the computer-aided analysis of digital radiographs via measurements of profiles, wall thickness
More informationPart 3: Image quality classes
INTERNATIONAL STANDARD ISO 19232-3 Second edition 2013-06-15 Non-destructive testing Image quality of radiographs Part 3: Image quality classes Essais non destructifs Qualité d image des radiogrammes Partie
More information5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico
QUALIFICATION PROCESS AND INSPECTION VALIDATION OF COMPUTED RADIOGRAPHY TECHNIQUE FOR DWDI WELD INSPECTION Carla Alves MARINHO 1, José Maurício RABELLO, Marcos AIUB, Eduardo IGUCHI, Ricardo LOPES 2, Davi
More informationExamination of Pipe Welds by Image Plate Based Computed Radiography System
Examination of Pipe Welds by Image Plate Based Computed Radiography System Sanjoy Das, M.S.Rana, Benny Sebastian, D. Mukherjee and K.K. Abdulla Atomic Fuels Division Bhabha Atomic Research Centre Mumbai
More informationAUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS
International Workshop SMART MATERIALS, STRUCTURES & NDT in AEROSPACE Conference NDT in Canada 2011 2-4 November 2011, Montreal, Quebec, Canada AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF
More informationISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film
INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés
More informationISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors
INTERNATIONAL STANDARD ISO 17636-2 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors Contrôle non destructif des
More informationON THE WAY TO DIGITAL RADIOGRAPHY
The 14 th International Conference of the Slovenian Society for Non-Destructive Testing»Application of Contemporary Non-Destructive Testing in Engineering«September 4-6, 2017, Bernardin, Slovenia More
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 16371-1 First edition 2011-10-01 Non-destructive testing Industrial computed radiography with storage phosphor imaging plates Part 1: Classification of systems Essais non destructifs
More informationDürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr
lndustrial Computed Radiography with storage phosphor imaging plates results of a classification of the system Dürr HD-CR 35 NDT scanner with blue HD- IP Plus imaging plates (HD-IP + ) BAM reference BAM
More informationPhased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2
More Info at Open Access Database www.ndt.net/?id=15156 Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2 1 GE Inspection Technologies,
More informationDigital Radiology with Photon Counting Detectors
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Digital Radiology with Photon Counting Detectors More Info at Open Access Database www.ndt.net/?id=16709
More informationAdvanced Digital Radiography for Field NDT
International Symposium on Digital Industrial Radiology and Computed Tomography - We.2.3 Advanced Digital Radiography for Field NDT Ron PINCU, Ofra KLEINBERGER-RIEDRICH Vidisco Ltd. 32 Haharoshet Street,
More informationA COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16394 A COMPARATIVE STUDY ON THE PERFORMANCE
More informationOverview. Optimization of Industrial Radiography Technique for Defect Detection of Oil and Gas Pipelines in Weld Regions by Image Processing
Optimization of Industrial Radiography Technique for Defect Detection of Oil and Gas Pipelines in Weld Regions by Image Processing Alireza karimian (University of Isfahan- Isfahan - Iran) Monir Torabian
More informationDACON INSPECTION SERVICES. Computed RADIOGRAPHY
CR Computed RADIOGRAPHY Who we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400 personnel including more than 300 inspectors
More informationRadiographic testing: Increased detection sensitivity using optimum source to object distance
18 th World Conference on Non destructive Testing, 16-20 April 2012, Durban, South Africa Radiographic testing: Increased detection sensitivity using optimum source to object distance Jan Hendrik COWAN
More informationRADIOGRAPHIC EXPOSURE
RADIOGRAPHIC EXPOSURE Receptor Exposure Receptor Exposure the that interacts with the receptor. Computed Radiography ( ) requires a. Direct Digital Radiography (DR) requires a. Exposure Indicators Exposure
More informationAmorphous Selenium Direct Radiography for Industrial Imaging
DGZfP Proceedings BB 67-CD Paper 22 Computerized Tomography for Industrial Applications and Image Processing in Radiology March 15-17, 1999, Berlin, Germany Amorphous Selenium Direct Radiography for Industrial
More informationAdvancements In Digital Radiography: CR, DR, and DICONDE
Advancements In Digital Radiography: CR, DR, and DICONDE Leo BOIY and Rick CUSCINO, GE Sensing & Inspection Technologies, Berchem, Belgium and Lewistown, USA Introduction Imaging in today s digital age
More informationMinimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations
More Info at Open Access Database www.ndt.net/?id=16708 Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations Uwe EWERT, Uwe
More informationEngineering Policy & Procedure
FPD > Engineering > Global Standards Engineering Policy & Procedure Revision History Number: G2-4 Section: G Subject: Radiographic Examination Procedure 1.0 SCOPE This procedure specifies the requirements
More informationMigrating from traditional to Digital Radiography in Aerospace
Migrating from traditional to Digital Radiography in Aerospace More info about this article: http://www.ndt.net/?id=22663 Abstract Lennart Schulenburg VisiConsult X-ray System & Solutions GmbH Brandenbrooker
More informationRay Detection Digital Image Quality and Influential Factors
7th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Ray Detection Digital Image Quality and Influential Factors Xiangzhao ZENG (Qingyuan, Guangdong, China Guangdong Yingquan
More informationDigital Radiography for the Inspection of Small Defects
ECNDT 2006 - Th.3.2.3 Digital Radiography for the Inspection of Small Defects Bruce Blakeley, TWI, Cambridge, UK Konstantinos Spartiotis, Ajat, Espoo, Finland Abstract. Digital Radiography offers several
More informationA True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR
A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY Series 4 CR Fujifilm, the absolute pioneer in digitized medical X-ray imaging advanced into the industrial inspection field
More informationPRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY
19 th World Conference on Non-Destructive Testing 2016 PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY Steven MANGO 1 1 Carestream
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés
More informationNew Developments in Automated Inspection for Corrosion under Insulation
ECNDT 2006 - Mo.2.5.5 New Developments in Automated Inspection for Corrosion under Insulation John RUDLIN, TWI Limited, Cambridge, UK Abstract - Detection of corrosion under insulation (CUI) has been a
More informationSeminar 8. Radiology S8 1
Seminar 8 Radiology Medical imaging. X-ray image formation. Energizing and controlling the X-ray tube. Image detectors. The acquisition of analog and digital images. Digital image processing. Selected
More informationQUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger
QUANTITATIVE COMPUTERIZED LAMINOGRAPHY Suzanne Fox Buchele and Hunter Ellinger Scientific Measurement Systems, Inc. 2201 Donley Drive Austin, Texas 78758 INTRODUCTION Industrial computerized-tomography
More informationUnit thickness. Unit area. σ = NΔX = ΔI / I 0
Unit thickness I 0 ΔI I σ = ΔI I 0 NΔX = ΔI / I 0 NΔX Unit area Δx Average probability of reaction with atom for the incident photons at unit area with the thickness of Delta-X Atom number at unit area
More informationWelding Inspection Non-Destructive Testing Course Reference WIS 5
Welding Inspection Non-Destructive Testing Course Reference WIS 5 Non Destructive Testing A welding inspector should have a working knowledge of NDT methods and their applications, advantages and disadvantages.
More informationVisibility of Detail
Visibility of Detail Radiographic Quality Quality radiographic images represents the, and information is for diagnosis. The of the anatomic structures and the accuracy of their ( ) determine the overall
More informationEquivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers
Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers More info about this article: http://www.ndt.net/?id=22782 Abstract
More informationPipe corrosion and deposit study usingneutron- and gamma- radiation sources
Nuclear Instruments and Methods in Physics Research A 542 (2005) 302 308 www.elsevier.com/locate/nima Pipe corrosion and deposit study usingneutron- and gamma- radiation sources Márton Balasko a,, Erzse
More informationAPPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES
APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES Davi F. OLIVEIRA, Edson V. MOREIRA, Aline S. S. SILVA, José M. B. RABELLO, Ricardo T. LOPES, Marcelo S. PEREIRA, Uwe ZSCHERPEL
More informationDürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr
Industrial Computed Radiography with storage phosphor imaging plates results of a classification of the system Dürr HD-CR 35 NDT Plus scanner using HD-IP Plus imaging plates (HD-IP + ) BAM reference BAM
More informationGamex CR 2.0 Program description and operating manual
Gamex CR 2.0 Program description and operating manual Issue No. : 2.0 Date of Issue : Jan. 2013 Z.U.T. NDT SOFT http://www.ndtsoft.eu Copyright (c) 2013 by Z.U.T. NDT SOFT All Rights Reserved Disclaimer
More informationISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded
INTERNATIONAL STANDARD ISO 17636 First edition 2003-09-15 Non-destructive testing of welds Radiographic testing of fusionwelded joints Contrôle non destructif des assemblages soudés Contrôle par radiographie
More informationIntroduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image
Introduction Chapter 16 Diagnostic Radiology Radiation Dosimetry I Text: H.E Johns and J.R. Cunningham, The physics of radiology, 4 th ed. http://www.utoledo.edu/med/depts/radther In diagnostic radiology
More informationPerformance evaluation of a photon counting detector for high energy NDT applications
Performance evaluation of a photon counting detector for high energy NDT applications More info about this article: http://www.ndt.net/?id=22842 Abstract Angela Peterzol 1, Pascal Brun 1, Charlotte Eriksson
More informationNON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS
19 th World Conference on Non-Destructive Testing 2016 NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS Brian S. WHITE 1 1 Carestream NDT, 1049 Ridge Road West, Rochester,
More informationHardware for High Energy Applications 30 October 2009
Paper No. 003 09 Hardware for High Energy Applications 30 October 2009 This document was created by the Federal Working Group on Industrial Digital Radiography. Reproduction is authorized. Federal Working
More informationCalibration of KAP meters
Calibration of KAP meters Alexandr Malusek! Division of Radiological Sciences Department of Medical and Health Sciences Linköping University! 2014-04-15 1 Outline 1. KAP meter construction 2. Air kerma-area
More informationDetermination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes
More info about this article: http://www.ndt.net/?id=21129 Determination of Optimum X-Ray Tube Output Parameters kv and for Digital Radiography Testing of Welded Tubes AyazJhanorwala, SatishTilva, L &
More informationSITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9
Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.
More informationCARESTREAM INDUSTREX Digital Imaging Plates
2016-09-29 TI-2632 CARESTREAM INDUSTREX Digital Imaging Plates CARESTREAM INDUSTREX Flex Digital Imaging Plates (IPs) are designed for computed radiography in nondestructive testing applications. These
More informationDigital Radiography and its Advantages in Field NDT Inspections Today
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Digital Radiography and its Advantages in Field NDT Inspections Today Ron PINCU NDT Division Manager, Vidisco Ltd. 32 Haharoshet
More informationDigital Radiography, Flexible Risers
Digital radiography is currently considered to be a new and exciting technique within the field of industrial radiography. Gradually, quality levels and costs of equipment have reached a level where the
More informationRelated topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation
Beam hardening and metal artefacts TEP Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation Principle X-ray sources produce a polychromatic spectrum
More informationImage Analysis For Virtual Segregation Of Overlapped Radiographic Images
National Seminar & Exhibition on Non-Destructive Evaluation, NDE 2014, Pune, December 4-6, 2014 (NDE-India 2014) Vol.20 No.6 (June 2015) - The e-journal of Nondestructive Testing - ISSN 1435-4934 www.ndt.net/?id=17832
More informationConversion to Digital Radiography from Film Radiography
Conversion to Digital Radiography from Film Radiography Steve Mango Worldwide Technical Manager Carestream NDT Rochester, NY Overview: Overview of digital Basic computed radiography (CR) Basic digital
More informationIn-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing
ISO 2016 All rights reserved ISO/TC 85/SC 6 N 230 Date: 2017-01-12 ISO/CD 20890-6:2016(E) ISO/TC 85/SC 6/WG 3 Secretariat: ANSI In-service inspections for primary coolant circuit components of light water
More informationIntroduction To NDT. BY: Omid HEIDARY
Introduction To NDT BY: Omid HEIDARY NDT Methods Penetrant Testing Magnetic Particle Testing Eddy Current Testing Ultrasonic Testing Radiographic Testing Acoustic Emission Infrared Testing Visual Testing
More informationHalf value layer and AEC receptor dose compliance survey in Estonia
Half value layer and AEC receptor dose compliance survey in Estonia K. Kepler, A. Vladimirov Training Centre of Medical Physics, University of Tartu Testing Centre of the University of Tartu, Estonia E-mail:
More informationGafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications
GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications I. SCOPE The protocol applies to GafChromic EBT3P and EBT3+P films exposed in GafChromic QuiCk Phantom
More informationX-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto
X-ray Imaging PHYS Lecture Carlos Vinhais Departamento de Física Instituto Superior de Engenharia do Porto cav@isep.ipp.pt Overview Projection Radiography Anode Angle Focal Spot Magnification Blurring
More informationRAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II
RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II APPROVED 12/O2/2011 EFFECTIVE SPRING 2013-14 Prefix & Number RAD 150 Course Title: Radiologic Exposure Technique II & Lab Purpose of this submission: New Change/Updated
More informationPhoton Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications
19 th World Conference on Non-Destructive Testing 2016 Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications David WALTER 1, Uwe ZSCHERPEL 1, Uwe EWERT 1 1 BAM Bundesanstalt
More informationIBEX TECHNOLOGY APPLIED TO DIGITAL RADIOGRAPHY
WHITE PAPER: IBEX TECHNOLOGY APPLIED TO DIGITAL RADIOGRAPHY IBEX Innovations Ltd. Registered in England and Wales: 07208355 Address: Discovery 2, NETPark, William Armstrong Way, Sedgefield, UK Patents:
More informationVeterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS
Veterinary Science Preparatory Training for the Veterinary Assistant Floron C. Faries, Jr., DVM, MS Radiology Floron C. Faries, Jr., DVM, MS Objectives Determine the appropriate machine settings for making
More informationDOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER
14.03.2016 DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS Bernhard REDMER Digital Technology and Networking Imaging Plates Scanner for Imaging Plates Data Transmission Reporting Computed Radiography
More informationTomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams
ECNDT 2006 - We.3.2.3 Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams Bernhard REDMER, Uwe EWERT Federal Institute of Materials Research and Testing (BAM),
More informationDIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.
DIGITAL RADIOGRAPHY Digital radiography is a film-less technology used to record radiographic images. 1 The purpose of digital imaging is to generate images that can be used in the diagnosis and assessment
More information17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Real-time Radiographic Non-destructive Inspection for Aircraft Maintenance Xin Wang 1, B. Stephen Wong 1, Chen Guan Tui
More informationThe Probe KK&S INSTRUMENTS - April / June 2013
Issue 10 The Probe KK&S INSTRUMENTS - April / June 2013 In this issue: 1. Cover Story Sigmascope Conductivity Meter 2. Special 15% OFF Echograph Flaw Detectors 3. News NEW Echometer 1077 Precession & 1077K
More informationThe field deployable digital X-Ray solution for weld inspection in O&G
The field deployable digital X-Ray solution for weld inspection in O&G Imagination at work. Haitham Ibrahim, Hanley Thomas, Steven Wissels 7 th MENDT Conference Bahrain Agenda Field inspection Actual weld
More informationRADIOGRAPHIC EXAMINATION PROCEDURE
Page 1 of 19 Doc. No. KNS/RT/01.REV 0 RADIOGRAPHIC EXAMINATION PROCEDURE Page: 19 of 19 Date: 15.09.2012 RADIOGRAPHIC EXAMINATION PROCEDURE PREPARED & APPROVED BY NDE- Level III CERTIFIED BY REVIEWED BY
More informationCOMPUTED RADIOGRAPHY THE STATE OF THE ART
2007 International Nuclear Atlantic Conference - INAC 2007 Santos, SP, Brazil, September 30 to October 5, 2007 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-02-1 COMPUTED RADIOGRAPHY
More informationSpokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales
Spokane Industries Computed Radiography Implementation Experience David Jolin Technical Sales djolin@spokaneindustries.com Outline Background Our Decision for Computed Radiography Implementation of CR
More informationMultiple Choice Identify the letter of the choice that best completes the statement or answers the question.
RA110 test 3 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. An object 35 cm in width is radiographed at 100 cm SID and at a 50 cm SOD. What
More informationMobile digital radiography system for nondestructive testing of large diameter pipelines
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Mobile digital radiography system for nondestructive testing of large diameter pipelines Vasily A. KLIMENOV, Aleksey
More informationCalibration Aids for Metron
Calibration Aids for Metron Equine 877-638-3868 metron@dvmconnexx.com www.dvmconnexx.com www.metron-imaging.com 2009-2013 DVMCONNEXX. All rights reserved. Calibration Aids for Metron Equine YOUR METRON
More informationCOMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY
COMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY MY1204107 Noorhazleena Azaman, Khairul Anuar Mohd Salleh, Sapizah Rahim, Shaharudin Sayuti, Arshad Yassin, Ab. Razak Hamzah Non
More informationPhilip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.
A new generation of x-ray computed tomography devices for quality inspection and metrology inspection in the field of additive manufacturing and other sciences Philip Sperling Sales Science and New Materials,
More informationPreliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography
ECNDT 26 - Poster 17 Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography Khairul Anuar MOHD SALLEH, Ab. Razak HAMZAH and Mohd Ashhar
More informationv tome x m microfocus CT
GE Inspection Technologies v tome x m microfocus CT Uniting premium 3D metrology and inspection with quality and speed. gemeasurement.com/ct x plore precision CT line Inspect with precision, power, and
More informationDigital Radiography : Flat Panel
Digital Radiography : Flat Panel Flat panels performances & operation How does it work? - what is a sensor? - ideal sensor Flat panels limits and solutions - offset calibration - gain calibration - non
More information