Projection Radiography. application on stream

Size: px
Start display at page:

Download "Projection Radiography. application on stream"

Transcription

1 Projection Radiography application on stream common research project BASF and BAM, later with AGFA/GE IT, IT, IAEA: computer based radiographic wall wall thickness measurement contents: --basic principles --software for forevaluation and and documentation --corrosion depth evaluation --validation of of methods 1

2 Projection Radiography Examples on Corrosion and Erosion Corrosion and Seads Corrosion Erosion 2

3 History: radiographic wall thickness evaluation applied since ca nearly no literature until 1980 growing importance in chemical industry caused by onstream application since 1996 projects BASF und BAM for physical studies standardization open (IAEA Draft) BASF drawing from

4 classical set-up: typical exposure: radiation source, Ir 192 insulation pipe line film, imaging plate, or flat panel profile line 4

5 Projection Radiography Example : distribution station film source on-site exposure, Ir 192 radiograph 5

6 Projection Radiography visual evaluation of wall thickness error sources: w - wrong density range - inaccurate edge detection (unsharpness) - wrong magnification factor 6

7 Principle of projection radiography tangential penetration of pipe wall f - film focus distance r - outer pipe radius R - outer radius of insulation w - wall thickness projection on detector plane pipe insulation w` measured on film 7

8 Projection Radiography PC based wall thickness measurement overview of measurement equipment (BASF at 2000, before CR): RT exposure scanner PC protocol screen/film : film digitisation RCF + F8 (16 bit, 300 dpi) (7% of exposure time of Pb+D7) software for measurement (algorithms) and documentation data base 8

9 Projection Radiography PC based wall thickness measurement film digitisation imaging plate flat panel single program for evalution of all digital images, no size limitation support for all detectors by external 16 bit LUT tables for linearisation (gray value proportional to radiation intensity) 9

10 16 bit software platform wtscope.exe image processing know-how on on Windows PC: (ISee!, see --fully fully16 16 bit bitdata datadepth for forevaluation and and display --unlimited image sizes, limited only onlyby bymain mainmemory (>1 (>1 GByte) --all all detectors (digitized film, film, imaging plates, flat flatpanel detectors) via via external bit bitlookup Tables (LUT) linearizable, ASCII text text -fast - fast rekursive moving average filtering for forarbitrary sizes sizesof of high high and and low lowpass filters, convolution with withvariable kernels (ASCII text) text) --sub-sampling for forimage display with withtrue trueaveraging --error errorestimation for formeasured values and and geometric correction --quick documentation of of measurements by byprotocol generation and and transfer to to Word --protection of of application by byindividual encrypted license keys keys 10

11 Projection Radiography PC based wall thickness measurement input exposure parameters wall thickness result table with measurement regions tangential wall thickness algorithm wall thickness deviation in measurement region 11

12 synchronous display of positions in profile and image! position correction by hand, if algorithm fails! 12

13 Projection Radiography PC generated measurement protocol 13

14 Projection Radiography Algorithms : PC based wall thickness measurement problem: correct detection of wall positions characteristic points, curve fitting, CT reconstr. inner wall of pipe max. outer wall of pipe projected wall thickness w 14

15 Limits of of Tangential Radiography (TRT): L max W L max = 2W sqrt(d a /W 1) 300 kv 200 kv Energy: L max 100 kv : 10 mm 200 kv : 30 mm 300 kv : 40 mm 400 kv : 50 mm Se-75 : 60 mm Ir-192 : 75 mm Co-60 : 120 mm 15

16 Radiographic Evaluation of Corrosion and Deposits in Pipelines: Results of an IAEA Co-ordinated Research Programme Steel pipes up up to to 20 with NDT film and X-ray, Ir-192, Co Algeria Hungary Romania Iran Pakistan Germany Uruguay Syria India Turkey Malaysia Canada 16

17 Fabricated Reference Blocks with Steps and Holes: Iran Idea: explore inspection methods with known wall thicknesses 17

18 18

19 algorithm detects edges, visual not seeable in image : extension of application range in comparison to visual evaluation Ir 192, DN200: 6 11 mm Co 60, DN300: mm 19

20 2005: Validation of of wtscope, CR-Tower and Ir-192 BAM BASF GE IT 20

21 Validation as as measurement method according to to ISO 17025: Steel pipes mm dia, empty, water filled, w/o insulation 21

22 Radiographic Corrosion Inspection Two inspection techniques possible : 2. Corrosion assessment from local film density changes (Double Wall Technique, DWT) 22

23 local corrosion : wall thickness differences in penetration direction (DWT) source pipe erosion w-δw intensity change, ΔI attenuation law: detector I w = I 0 e -µ eff w µ eff - effective attenuation coefficient relative measurement: 1. Calibration: 2. Measurement: 2 step algorithm µ eff = ln ( D REF / D IQI ) / Δw IQI Δw = ln ( D REF / D MEAS ) / µ eff 23

24 DWT for local corrosion 1. Calculation of effective attenuation coefficient µ eff known hole depth signal at measurement point signal at reference point known pipe wall thickness w at reference point Result: µ eff eff = f(w) dep. on on radiation energy and wall thickness differences 24

25 IAEA CRP, film Calculated attenuation coefficient (1/mm) 0,50 0,45 0,40 0,35 0,30 0,25 0,20 0,15 0,10 0,05 0,00 Double wall technique 6" and 8", 100 kv, with and without insulation y = 0,6689x -0,3385 R 2 = 0,7316 y = 0,5039x -0,3927 R 2 = 0, Penetrated steel wall thickness (mm) Iran, Uruguay insulation decreasing µ eff eff with penetrated wall and insulation 25

26 IAEA CRP, film 0,10 0,09 Double wall technique, Ir 192 Ir-192 Calculated attenuation coefficient (1/mm) 0,08 0,07 0,06 0,05 0,04 0,03 0,02 0,01 0,00 Uruguay Iran Uruguay with Insulation Iran with Insulation Penetrated steel wall thickness (mm) % of of all all measurements: µ eff eff = /- +/ mm

27 IAEA CRP, film 0,045 Double wall technique Co-60 Calculated attenuation coefficient [1/mm] 0,040 0,035 0,030 0,025 0,020 0,015 0,010 0,005 0,000 12" pipe 8" pipe mean µeff Penetrated steel wall thickenss [mm] % of of all all measurements: µ eff eff = /- +/ mm

28 Computer based evaluation with withwtscope/isee! software: accuracy mm, mm, µ eff =0.028/mm eff 28

29 Comparison Film // CR DWT with Ir-192: Result of wtscope validation for CR Tower by BAM / BASF / GE IT effective attenuation coefficient [1/mm] 0,06 0,05 0,04 0,03 0,02 0,01 µ eff CR Film reason: scatter sensitivity! pipe wall thickness [mm] 29

30 Projection Radiography Summary program for PC based routine measurements on images from all radiographic detectors, tangential wall thickness measurement and local corrosion, simple documentation wall thickness range enlarged compared with visual evaluation in projection radiography measurement of corrosion depth (in centre of pipe) validation as measurement methods acc. to ISO programs transfered to GE IT for worldwide marketing (Rhythm Version 2 all methods implemented) differences in sensitivity to scattered radiation between film and imaging plates inspection technique not standardised, written practice necessary! standard development has to be started soon 30

31 The End 31

Pre Conference Workshop on Advanced Digital imaging

Pre Conference Workshop on Advanced Digital imaging Pre Conference Workshop on Advanced Digital imaging Uwe Zscherpel, uwez@bam.de BAM Federal Institute for Materials Research and Testing, Division 8.3 Radiological Methods, Berlin, Germany 1 Content: 1.

More information

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Film Replacement in Radiographic Weld Inspection The New ISO Standard BAM Berlin Film Replacement in Radiographic Weld Inspection The New ISO Standard 17636-2 Uwe Ewert, Uwe Zscherpel, Mirko Jechow Requests and information to: uwez@bam.de 1 Outline - The 3 essential parameters

More information

Computed Radiography

Computed Radiography BAM Berlin Computed Radiography --INDE 2007, Kalpakkam, India -- Uwe Zscherpel, Uwe Ewert BAM Berlin, Division VIII.3 Requests Requests and and information information to: to: Dr. Dr. U. U. Zscherpel Zscherpel

More information

Fig.2: Scanner VistaScan for image plates

Fig.2: Scanner VistaScan for image plates RADIOGRAPHIC INSPECTION OF WELDINGS BY DIGITAL SENSORS H. Thiele, H.-J. Friemel RADIS GmbH, Johanniskirchen, Germany Abstract: The newly available digital sensors for radiographic inspection are suitable

More information

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012 The HOIS recommended practice for in-service computed radiography of pipes WCNDT 2012, Durban, SA. April 2012 Dr Stephen F Burch, ESR Technology, Oxfordshire,UK steve.burch@esrtechnology.com ESR Technology

More information

Experiences of users in Digital Radiography

Experiences of users in Digital Radiography Computed Radiography Products & Applications Experiences of users in Digital Radiography Jimmy Opdekamp May Jimmy 2006Opdekamp Global Product Manager CR Int l Workshop Imaging NDT Chennai, 25-28 April

More information

The HOIS recommended practice for in-service computed radiography of pipes

The HOIS recommended practice for in-service computed radiography of pipes 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa The HOIS recommended practice for in-service computed radiography of pipes Stephen F. BURCH, ESR Technology Ltd 16

More information

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique Recommended Techniques» There are many possible techniques for making good radiographs using CR» Following a defined procedure will simplify technique development and shorten the time to a good image»

More information

Overview. Corrosion detection improvement of oil and gas pipelines with industrial radiography method by using image processing.

Overview. Corrosion detection improvement of oil and gas pipelines with industrial radiography method by using image processing. detection improvement of oil and gas pipelines with industrial radiography method by using image processing Alireza Karimian (Engineering faculty of Isfahan university, Isfahan,, Iran ) Sepideh Yazdani

More information

ScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)

ScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR) Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 69 ( 2014 ) 1216 1224 24th DAAAM International Symposium on Intelligent Manufacturing and Automation, 2013 Evaluation of Pipe

More information

Digital Profile Radiography Practical uses and limitations

Digital Profile Radiography Practical uses and limitations Digital Profile Radiography Practical uses and limitations Mr. Neil Young Asset Reliability Inspections Bunbury, Australia www.ari.com.au neil.young@ari.com.au Introduction Profile digital radiography

More information

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology Uwe EWERT, Uwe ZSCHERPEL, Mirko

More information

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations uwe.ewert@bam.de Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations Uwe Ewert and Uwe Zscherpel BAM Federal Institute for

More information

Digital Profile Radiography Practical uses and limitations

Digital Profile Radiography Practical uses and limitations More info ab Digital Profile Radiography Practical uses and limitations Mr. Neil Young Asset Reliability Inspections Bunbury, Australia www.ari.com.au neil.young@ari.com.au Introduction Profile digital

More information

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography 7 th European-American Workshop on Reliability of NDE Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography Uwe EWERT, Uwe ZSCHERPEL, Justus VOGEL, Fangzhou ZHANG

More information

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY 12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY Rajashekar

More information

Gamex Lite 3.0 Program description and operating manual

Gamex Lite 3.0 Program description and operating manual Gamex Lite 3.0 Program description and operating manual Issue No. : 3.0 Date of Issue : 12-2013 Z.U.T. NDT SOFT http://www.ndtsoft.eu Copyright (c) 2013 by Z.U.T. NDT SOFT All Rights Reserved Disclaimer

More information

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices Moving from film to digital: A study of digital x-ray benefits, challenges and best practices H.U. Pöhler 1 and N. D Ademo 2 DÜRR NDT GmbH & Co. KG, Höpfigheimer Straße 22, Bietigheim-Bissingen, 74321,

More information

THE CR SPECIALISTS HD-CR CR 35 NDT

THE CR SPECIALISTS HD-CR CR 35 NDT THE CR SPECIALISTS HD-CR CR 35 NDT COMPUTED RADIOGRAPHY SYSTEMS Digital Intelligence Ready to Change. www.duerr-ndt.com VERSATILE AND DEPENDABLE HIGH-TECH MADE IN GERMANY Highest resolution DÜRR NDT is

More information

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

Digital Radiographic Inspection replacing traditional RT and 3D RT Development Digital Radiographic Inspection replacing traditional RT and 3D RT Development Iploca Novel Construction Meeting 27&28 March 2014 Geneva By Jan van der Ent Technical Authority International Contents Introduction

More information

Strategies for Film Replacement in Radiography - a comparative study -

Strategies for Film Replacement in Radiography - a comparative study - IV Conferencia Panamericana de END Buenos Aires Octubre 2007 Strategies for Film Replacement in Radiography - a comparative study - 1 Uwe Ewert, 1 Uwe Zscherpel, 2 Klaus Bavendiek 1 BAM-Berlin, Federal

More information

User manual for the measuring program IC.exe ISee!

User manual for the measuring program IC.exe ISee! User manual for the page 1 of 40 BAM User manual for the measuring program IC.exe ISee! This software allows the computer-aided analysis of digital radiographs via measurements of profiles, wall thickness

More information

Part 3: Image quality classes

Part 3: Image quality classes INTERNATIONAL STANDARD ISO 19232-3 Second edition 2013-06-15 Non-destructive testing Image quality of radiographs Part 3: Image quality classes Essais non destructifs Qualité d image des radiogrammes Partie

More information

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico QUALIFICATION PROCESS AND INSPECTION VALIDATION OF COMPUTED RADIOGRAPHY TECHNIQUE FOR DWDI WELD INSPECTION Carla Alves MARINHO 1, José Maurício RABELLO, Marcos AIUB, Eduardo IGUCHI, Ricardo LOPES 2, Davi

More information

Examination of Pipe Welds by Image Plate Based Computed Radiography System

Examination of Pipe Welds by Image Plate Based Computed Radiography System Examination of Pipe Welds by Image Plate Based Computed Radiography System Sanjoy Das, M.S.Rana, Benny Sebastian, D. Mukherjee and K.K. Abdulla Atomic Fuels Division Bhabha Atomic Research Centre Mumbai

More information

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS International Workshop SMART MATERIALS, STRUCTURES & NDT in AEROSPACE Conference NDT in Canada 2011 2-4 November 2011, Montreal, Quebec, Canada AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors INTERNATIONAL STANDARD ISO 17636-2 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors Contrôle non destructif des

More information

ON THE WAY TO DIGITAL RADIOGRAPHY

ON THE WAY TO DIGITAL RADIOGRAPHY The 14 th International Conference of the Slovenian Society for Non-Destructive Testing»Application of Contemporary Non-Destructive Testing in Engineering«September 4-6, 2017, Bernardin, Slovenia More

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 16371-1 First edition 2011-10-01 Non-destructive testing Industrial computed radiography with storage phosphor imaging plates Part 1: Classification of systems Essais non destructifs

More information

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr lndustrial Computed Radiography with storage phosphor imaging plates results of a classification of the system Dürr HD-CR 35 NDT scanner with blue HD- IP Plus imaging plates (HD-IP + ) BAM reference BAM

More information

Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2

Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2 More Info at Open Access Database www.ndt.net/?id=15156 Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2 1 GE Inspection Technologies,

More information

Digital Radiology with Photon Counting Detectors

Digital Radiology with Photon Counting Detectors 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Digital Radiology with Photon Counting Detectors More Info at Open Access Database www.ndt.net/?id=16709

More information

Advanced Digital Radiography for Field NDT

Advanced Digital Radiography for Field NDT International Symposium on Digital Industrial Radiology and Computed Tomography - We.2.3 Advanced Digital Radiography for Field NDT Ron PINCU, Ofra KLEINBERGER-RIEDRICH Vidisco Ltd. 32 Haharoshet Street,

More information

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16394 A COMPARATIVE STUDY ON THE PERFORMANCE

More information

Overview. Optimization of Industrial Radiography Technique for Defect Detection of Oil and Gas Pipelines in Weld Regions by Image Processing

Overview. Optimization of Industrial Radiography Technique for Defect Detection of Oil and Gas Pipelines in Weld Regions by Image Processing Optimization of Industrial Radiography Technique for Defect Detection of Oil and Gas Pipelines in Weld Regions by Image Processing Alireza karimian (University of Isfahan- Isfahan - Iran) Monir Torabian

More information

DACON INSPECTION SERVICES. Computed RADIOGRAPHY

DACON INSPECTION SERVICES. Computed RADIOGRAPHY CR Computed RADIOGRAPHY Who we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400 personnel including more than 300 inspectors

More information

Radiographic testing: Increased detection sensitivity using optimum source to object distance

Radiographic testing: Increased detection sensitivity using optimum source to object distance 18 th World Conference on Non destructive Testing, 16-20 April 2012, Durban, South Africa Radiographic testing: Increased detection sensitivity using optimum source to object distance Jan Hendrik COWAN

More information

RADIOGRAPHIC EXPOSURE

RADIOGRAPHIC EXPOSURE RADIOGRAPHIC EXPOSURE Receptor Exposure Receptor Exposure the that interacts with the receptor. Computed Radiography ( ) requires a. Direct Digital Radiography (DR) requires a. Exposure Indicators Exposure

More information

Amorphous Selenium Direct Radiography for Industrial Imaging

Amorphous Selenium Direct Radiography for Industrial Imaging DGZfP Proceedings BB 67-CD Paper 22 Computerized Tomography for Industrial Applications and Image Processing in Radiology March 15-17, 1999, Berlin, Germany Amorphous Selenium Direct Radiography for Industrial

More information

Advancements In Digital Radiography: CR, DR, and DICONDE

Advancements In Digital Radiography: CR, DR, and DICONDE Advancements In Digital Radiography: CR, DR, and DICONDE Leo BOIY and Rick CUSCINO, GE Sensing & Inspection Technologies, Berchem, Belgium and Lewistown, USA Introduction Imaging in today s digital age

More information

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations More Info at Open Access Database www.ndt.net/?id=16708 Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations Uwe EWERT, Uwe

More information

Engineering Policy & Procedure

Engineering Policy & Procedure FPD > Engineering > Global Standards Engineering Policy & Procedure Revision History Number: G2-4 Section: G Subject: Radiographic Examination Procedure 1.0 SCOPE This procedure specifies the requirements

More information

Migrating from traditional to Digital Radiography in Aerospace

Migrating from traditional to Digital Radiography in Aerospace Migrating from traditional to Digital Radiography in Aerospace More info about this article: http://www.ndt.net/?id=22663 Abstract Lennart Schulenburg VisiConsult X-ray System & Solutions GmbH Brandenbrooker

More information

Ray Detection Digital Image Quality and Influential Factors

Ray Detection Digital Image Quality and Influential Factors 7th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Ray Detection Digital Image Quality and Influential Factors Xiangzhao ZENG (Qingyuan, Guangdong, China Guangdong Yingquan

More information

Digital Radiography for the Inspection of Small Defects

Digital Radiography for the Inspection of Small Defects ECNDT 2006 - Th.3.2.3 Digital Radiography for the Inspection of Small Defects Bruce Blakeley, TWI, Cambridge, UK Konstantinos Spartiotis, Ajat, Espoo, Finland Abstract. Digital Radiography offers several

More information

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY Series 4 CR Fujifilm, the absolute pioneer in digitized medical X-ray imaging advanced into the industrial inspection field

More information

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY 19 th World Conference on Non-Destructive Testing 2016 PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY Steven MANGO 1 1 Carestream

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés

More information

New Developments in Automated Inspection for Corrosion under Insulation

New Developments in Automated Inspection for Corrosion under Insulation ECNDT 2006 - Mo.2.5.5 New Developments in Automated Inspection for Corrosion under Insulation John RUDLIN, TWI Limited, Cambridge, UK Abstract - Detection of corrosion under insulation (CUI) has been a

More information

Seminar 8. Radiology S8 1

Seminar 8. Radiology S8 1 Seminar 8 Radiology Medical imaging. X-ray image formation. Energizing and controlling the X-ray tube. Image detectors. The acquisition of analog and digital images. Digital image processing. Selected

More information

QUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger

QUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger QUANTITATIVE COMPUTERIZED LAMINOGRAPHY Suzanne Fox Buchele and Hunter Ellinger Scientific Measurement Systems, Inc. 2201 Donley Drive Austin, Texas 78758 INTRODUCTION Industrial computerized-tomography

More information

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

Unit thickness. Unit area. σ = NΔX = ΔI / I 0 Unit thickness I 0 ΔI I σ = ΔI I 0 NΔX = ΔI / I 0 NΔX Unit area Δx Average probability of reaction with atom for the incident photons at unit area with the thickness of Delta-X Atom number at unit area

More information

Welding Inspection Non-Destructive Testing Course Reference WIS 5

Welding Inspection Non-Destructive Testing Course Reference WIS 5 Welding Inspection Non-Destructive Testing Course Reference WIS 5 Non Destructive Testing A welding inspector should have a working knowledge of NDT methods and their applications, advantages and disadvantages.

More information

Visibility of Detail

Visibility of Detail Visibility of Detail Radiographic Quality Quality radiographic images represents the, and information is for diagnosis. The of the anatomic structures and the accuracy of their ( ) determine the overall

More information

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers More info about this article: http://www.ndt.net/?id=22782 Abstract

More information

Pipe corrosion and deposit study usingneutron- and gamma- radiation sources

Pipe corrosion and deposit study usingneutron- and gamma- radiation sources Nuclear Instruments and Methods in Physics Research A 542 (2005) 302 308 www.elsevier.com/locate/nima Pipe corrosion and deposit study usingneutron- and gamma- radiation sources Márton Balasko a,, Erzse

More information

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES Davi F. OLIVEIRA, Edson V. MOREIRA, Aline S. S. SILVA, José M. B. RABELLO, Ricardo T. LOPES, Marcelo S. PEREIRA, Uwe ZSCHERPEL

More information

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr Industrial Computed Radiography with storage phosphor imaging plates results of a classification of the system Dürr HD-CR 35 NDT Plus scanner using HD-IP Plus imaging plates (HD-IP + ) BAM reference BAM

More information

Gamex CR 2.0 Program description and operating manual

Gamex CR 2.0 Program description and operating manual Gamex CR 2.0 Program description and operating manual Issue No. : 2.0 Date of Issue : Jan. 2013 Z.U.T. NDT SOFT http://www.ndtsoft.eu Copyright (c) 2013 by Z.U.T. NDT SOFT All Rights Reserved Disclaimer

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded INTERNATIONAL STANDARD ISO 17636 First edition 2003-09-15 Non-destructive testing of welds Radiographic testing of fusionwelded joints Contrôle non destructif des assemblages soudés Contrôle par radiographie

More information

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image Introduction Chapter 16 Diagnostic Radiology Radiation Dosimetry I Text: H.E Johns and J.R. Cunningham, The physics of radiology, 4 th ed. http://www.utoledo.edu/med/depts/radther In diagnostic radiology

More information

Performance evaluation of a photon counting detector for high energy NDT applications

Performance evaluation of a photon counting detector for high energy NDT applications Performance evaluation of a photon counting detector for high energy NDT applications More info about this article: http://www.ndt.net/?id=22842 Abstract Angela Peterzol 1, Pascal Brun 1, Charlotte Eriksson

More information

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS 19 th World Conference on Non-Destructive Testing 2016 NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS Brian S. WHITE 1 1 Carestream NDT, 1049 Ridge Road West, Rochester,

More information

Hardware for High Energy Applications 30 October 2009

Hardware for High Energy Applications 30 October 2009 Paper No. 003 09 Hardware for High Energy Applications 30 October 2009 This document was created by the Federal Working Group on Industrial Digital Radiography. Reproduction is authorized. Federal Working

More information

Calibration of KAP meters

Calibration of KAP meters Calibration of KAP meters Alexandr Malusek! Division of Radiological Sciences Department of Medical and Health Sciences Linköping University! 2014-04-15 1 Outline 1. KAP meter construction 2. Air kerma-area

More information

Determination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes

Determination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes More info about this article: http://www.ndt.net/?id=21129 Determination of Optimum X-Ray Tube Output Parameters kv and for Digital Radiography Testing of Welded Tubes AyazJhanorwala, SatishTilva, L &

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

CARESTREAM INDUSTREX Digital Imaging Plates

CARESTREAM INDUSTREX Digital Imaging Plates 2016-09-29 TI-2632 CARESTREAM INDUSTREX Digital Imaging Plates CARESTREAM INDUSTREX Flex Digital Imaging Plates (IPs) are designed for computed radiography in nondestructive testing applications. These

More information

Digital Radiography and its Advantages in Field NDT Inspections Today

Digital Radiography and its Advantages in Field NDT Inspections Today 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Digital Radiography and its Advantages in Field NDT Inspections Today Ron PINCU NDT Division Manager, Vidisco Ltd. 32 Haharoshet

More information

Digital Radiography, Flexible Risers

Digital Radiography, Flexible Risers Digital radiography is currently considered to be a new and exciting technique within the field of industrial radiography. Gradually, quality levels and costs of equipment have reached a level where the

More information

Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation

Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation Beam hardening and metal artefacts TEP Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation Principle X-ray sources produce a polychromatic spectrum

More information

Image Analysis For Virtual Segregation Of Overlapped Radiographic Images

Image Analysis For Virtual Segregation Of Overlapped Radiographic Images National Seminar & Exhibition on Non-Destructive Evaluation, NDE 2014, Pune, December 4-6, 2014 (NDE-India 2014) Vol.20 No.6 (June 2015) - The e-journal of Nondestructive Testing - ISSN 1435-4934 www.ndt.net/?id=17832

More information

Conversion to Digital Radiography from Film Radiography

Conversion to Digital Radiography from Film Radiography Conversion to Digital Radiography from Film Radiography Steve Mango Worldwide Technical Manager Carestream NDT Rochester, NY Overview: Overview of digital Basic computed radiography (CR) Basic digital

More information

In-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing

In-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing ISO 2016 All rights reserved ISO/TC 85/SC 6 N 230 Date: 2017-01-12 ISO/CD 20890-6:2016(E) ISO/TC 85/SC 6/WG 3 Secretariat: ANSI In-service inspections for primary coolant circuit components of light water

More information

Introduction To NDT. BY: Omid HEIDARY

Introduction To NDT. BY: Omid HEIDARY Introduction To NDT BY: Omid HEIDARY NDT Methods Penetrant Testing Magnetic Particle Testing Eddy Current Testing Ultrasonic Testing Radiographic Testing Acoustic Emission Infrared Testing Visual Testing

More information

Half value layer and AEC receptor dose compliance survey in Estonia

Half value layer and AEC receptor dose compliance survey in Estonia Half value layer and AEC receptor dose compliance survey in Estonia K. Kepler, A. Vladimirov Training Centre of Medical Physics, University of Tartu Testing Centre of the University of Tartu, Estonia E-mail:

More information

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications I. SCOPE The protocol applies to GafChromic EBT3P and EBT3+P films exposed in GafChromic QuiCk Phantom

More information

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto X-ray Imaging PHYS Lecture Carlos Vinhais Departamento de Física Instituto Superior de Engenharia do Porto cav@isep.ipp.pt Overview Projection Radiography Anode Angle Focal Spot Magnification Blurring

More information

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II APPROVED 12/O2/2011 EFFECTIVE SPRING 2013-14 Prefix & Number RAD 150 Course Title: Radiologic Exposure Technique II & Lab Purpose of this submission: New Change/Updated

More information

Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications

Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications 19 th World Conference on Non-Destructive Testing 2016 Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications David WALTER 1, Uwe ZSCHERPEL 1, Uwe EWERT 1 1 BAM Bundesanstalt

More information

IBEX TECHNOLOGY APPLIED TO DIGITAL RADIOGRAPHY

IBEX TECHNOLOGY APPLIED TO DIGITAL RADIOGRAPHY WHITE PAPER: IBEX TECHNOLOGY APPLIED TO DIGITAL RADIOGRAPHY IBEX Innovations Ltd. Registered in England and Wales: 07208355 Address: Discovery 2, NETPark, William Armstrong Way, Sedgefield, UK Patents:

More information

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS Veterinary Science Preparatory Training for the Veterinary Assistant Floron C. Faries, Jr., DVM, MS Radiology Floron C. Faries, Jr., DVM, MS Objectives Determine the appropriate machine settings for making

More information

DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER

DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER 14.03.2016 DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS Bernhard REDMER Digital Technology and Networking Imaging Plates Scanner for Imaging Plates Data Transmission Reporting Computed Radiography

More information

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams ECNDT 2006 - We.3.2.3 Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams Bernhard REDMER, Uwe EWERT Federal Institute of Materials Research and Testing (BAM),

More information

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images. DIGITAL RADIOGRAPHY Digital radiography is a film-less technology used to record radiographic images. 1 The purpose of digital imaging is to generate images that can be used in the diagnosis and assessment

More information

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Real-time Radiographic Non-destructive Inspection for Aircraft Maintenance Xin Wang 1, B. Stephen Wong 1, Chen Guan Tui

More information

The Probe KK&S INSTRUMENTS - April / June 2013

The Probe KK&S INSTRUMENTS - April / June 2013 Issue 10 The Probe KK&S INSTRUMENTS - April / June 2013 In this issue: 1. Cover Story Sigmascope Conductivity Meter 2. Special 15% OFF Echograph Flaw Detectors 3. News NEW Echometer 1077 Precession & 1077K

More information

The field deployable digital X-Ray solution for weld inspection in O&G

The field deployable digital X-Ray solution for weld inspection in O&G The field deployable digital X-Ray solution for weld inspection in O&G Imagination at work. Haitham Ibrahim, Hanley Thomas, Steven Wissels 7 th MENDT Conference Bahrain Agenda Field inspection Actual weld

More information

RADIOGRAPHIC EXAMINATION PROCEDURE

RADIOGRAPHIC EXAMINATION PROCEDURE Page 1 of 19 Doc. No. KNS/RT/01.REV 0 RADIOGRAPHIC EXAMINATION PROCEDURE Page: 19 of 19 Date: 15.09.2012 RADIOGRAPHIC EXAMINATION PROCEDURE PREPARED & APPROVED BY NDE- Level III CERTIFIED BY REVIEWED BY

More information

COMPUTED RADIOGRAPHY THE STATE OF THE ART

COMPUTED RADIOGRAPHY THE STATE OF THE ART 2007 International Nuclear Atlantic Conference - INAC 2007 Santos, SP, Brazil, September 30 to October 5, 2007 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-02-1 COMPUTED RADIOGRAPHY

More information

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales Spokane Industries Computed Radiography Implementation Experience David Jolin Technical Sales djolin@spokaneindustries.com Outline Background Our Decision for Computed Radiography Implementation of CR

More information

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. RA110 test 3 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. An object 35 cm in width is radiographed at 100 cm SID and at a 50 cm SOD. What

More information

Mobile digital radiography system for nondestructive testing of large diameter pipelines

Mobile digital radiography system for nondestructive testing of large diameter pipelines 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Mobile digital radiography system for nondestructive testing of large diameter pipelines Vasily A. KLIMENOV, Aleksey

More information

Calibration Aids for Metron

Calibration Aids for Metron Calibration Aids for Metron Equine 877-638-3868 metron@dvmconnexx.com www.dvmconnexx.com www.metron-imaging.com 2009-2013 DVMCONNEXX. All rights reserved. Calibration Aids for Metron Equine YOUR METRON

More information

COMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY

COMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY COMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY MY1204107 Noorhazleena Azaman, Khairul Anuar Mohd Salleh, Sapizah Rahim, Shaharudin Sayuti, Arshad Yassin, Ab. Razak Hamzah Non

More information

Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.

Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany. A new generation of x-ray computed tomography devices for quality inspection and metrology inspection in the field of additive manufacturing and other sciences Philip Sperling Sales Science and New Materials,

More information

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography ECNDT 26 - Poster 17 Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography Khairul Anuar MOHD SALLEH, Ab. Razak HAMZAH and Mohd Ashhar

More information

v tome x m microfocus CT

v tome x m microfocus CT GE Inspection Technologies v tome x m microfocus CT Uniting premium 3D metrology and inspection with quality and speed. gemeasurement.com/ct x plore precision CT line Inspect with precision, power, and

More information

Digital Radiography : Flat Panel

Digital Radiography : Flat Panel Digital Radiography : Flat Panel Flat panels performances & operation How does it work? - what is a sensor? - ideal sensor Flat panels limits and solutions - offset calibration - gain calibration - non

More information