Digital Radiographic Inspection replacing traditional RT and 3D RT Development
|
|
- Henry Miles
- 6 years ago
- Views:
Transcription
1 Digital Radiographic Inspection replacing traditional RT and 3D RT Development Iploca Novel Construction Meeting 27&28 March 2014 Geneva By Jan van der Ent Technical Authority International
2 Contents Introduction of Digital Radiography Advantages of digital radiography Digital Radiography inspection methodology RTD RAYSCAN system Digital detector and Image processing principle Time delayed integration Image Quality indicator Software features Practical benefits of RTD RAYSCAN Future development, 3D tomography 2
3 Introduction of Digital Radiography Radiographic image = x-ray image (photography) RTR = Real Time Radiography = direct x-ray image 3
4 Digital RTR vs. Conventional RT Advantages of digital vs. conventional RT: Shorter exposure times (due to high sensitivity) Reduced angle of radiation beam Improved radiation safety (lower kev) Direct on-line weld image display No residual products lower costs No use of chemicals No film Large dynamic range (multiple film classes covered) 4
5 Geometric unsharpness comparison Panoramic film Directional film RAYSCAN METHODOLOGY Detector External source Crawler IMAGE 1 IMAGE 2 IMAGE 3 Image 1 : Poor geometric un-sharpness, high radiation risk! Image 2 : Multiple exposures, high radiation risk! Image 3 : RAYSCAN system methodology Eliminates geometrical un-sharpness Eliminates multiple images Reduces the radiation risk 5
6 Movie Rayscan system 6
7 Digitial RT system development Shielded Unshielded 7
8 The heart of the Rayscan: Digital Sensor Active area Rayscan uses a digital sensor (like a digital photocamera... but for Xrays) The Xray-photographs are 6mm wide and up to 220mm long 300 photographs (or frames) a second are being made! Software re-constructs all photographs to a complete weldimage High efficiency of sensor makes it possible to inspect large wall thicknesses with relative low radiation. 8
9 Digital X-ray detector principle Direct detection of x rays with: Biased semiconductor Collection array X-ray photons hit the semiconductor X-ray photons generate charges in semiconductor Field separates charges Charges are processed by collection array Dielectric layer Incident x-ray Field photons electrode Semiconductor Collection array (signal to computer) 9
10 RTR inspection methodology DWSI technique used in the RTR system Tube and detector rotate around the pipe and the data is processed. After full rotation the whole weld is captured and processed by the software. Tube Pipe Detector 10
11 Time Delayed Integration (TDI) The detector has to read at least one image when it moves by the width of a pixel. The (e.g.) seven pixel rows of the detector acquire different parts of the weld (color). Tube Pipe 1. frame Detector 11
12 Time Delayed Integration (TDI) The detector moves. For the second acquisition the seven pixel rows cover a new area of the weld, i.e., additionally mid blue but not dark red anymore) The pixel rows are shifted by one row. Tube Pipe 2. frame frame Detector 12
13 Time Delayed Integration (TDI) After another acquisition the pixel rows are shifted by two with dark blue as an additional weld area. And so forth for all acquisitions! Tube Pipe 3. frame frame frame Detector 13
14 Image Reconstruction The software has to resort the acquired data by taking into account the shift in rows. The 1. frame gives the image data for the first seven pixels. The 2. frame is shifted by one pixels and is added to the image data shifted by one. The 3. frame is shifted by two pixels and added accordingly. 3. frame 2. frame 1. frame image data pixel position The image builds up from the frames by integration (summing up). The number of frames depends on the pixel rows of the detector. 14
15 RTD RayScan system performance Minimal motion un-sharpness No film un-sharpness Image quality equal or better than film or other digital RT High performance (using constant potential X-ray ) with lower radiation, see example below; Conventional directional X ray 300 kev x-ray radiation Digital CP RT 160 kev x-ray radiation Noise reduction improved image quality 15
16 Image Quality Indicators (IQI) According to EN 1435, soon to be accepted ISO part 1 and 2 (DR) IQI s are used to measure sensitivity and spatial resolution Single : Sensitivity Double : Spatial resolution Single wire IQI Double wire IQI (Rayleigh criterion >20%) 16
17 Image Enhancement with RTD RayScan Brightness Contrast Wall Thickness 16mm, 8 CS - 175kV, 4mA 17
18 Digital Zoom with RTD RayScan Cluster porosity Source side IQI 13th wire visible Scattered porosity Wall Thickness 16mm, 8 CS - 175kV, 4mA 18
19 Defect Evaluation and Marking 19
20 Practical Benefits of RTD RayScan Typical benefits of RTD RAYSCAN No films or consumables, no storage cabinets required No darkroom, no processors or chemicals (chemical waste) No waiting time for film development Less personnel (scanner tech + operator) Digital enhancement tools Lower radiation Wide range of pipe sizes and wall thickness However also the Digital radiographic inspection technique, despite the mentioned benefits, is limited to the use of standard workmanship acceptance criteria as no defect height can be measured. 20
21 3D Development: Applus RTD TomoCAR for Accurate Defect Sizing and Characterization 21
22 Why 3D Radiographic Inspection? Defect orientation Defects can be missed due to orientation Position of Source relative to film Defects can be missed due to orientation Operator subjective interpretation Influence of human judgment Probability of Detection Is negative influence by above factors Standard Radiographic Doesn t offer defect height sizing Main objectives are : To improve the Probability of Detection To introduce ECA based acceptance criteria into the RT inspection
23 Inspection principle 3D testing of objects projections High measurement time
24 Scanning in X direction through weld X X -scan direction Defect height visible in cross section 24
25 Defect height System Data analysis 25
26 Thank you! Jan van der Ent ApplusRTD Technical Authority Pipeline Department What is more in the pipeline? 26
Real Time Linear Array Imaging. Brian Caccamise
Real Time Linear Array Imaging Brian Caccamise 1 Real Time Linear Array Imaging What is Real Time Linear Array Imaging? Or Real Time Radiography (RTR)? 2 Real Time Linear Array Imaging It s Not This! Shoe
More informationDigital Radiography : Flat Panel
Digital Radiography : Flat Panel Flat panels performances & operation How does it work? - what is a sensor? - ideal sensor Flat panels limits and solutions - offset calibration - gain calibration - non
More informationHDRTR (High Definition Real Time Radiography)
Steve Morrison Shaw Pipeline Services HDRTR (High Definition Real Time Radiography) Advances in Technology API 2010 Winter Standards Meeting New Orleans, LA January 28, 2010 Gamma Radiographic Inspection
More informationFig.2: Scanner VistaScan for image plates
RADIOGRAPHIC INSPECTION OF WELDINGS BY DIGITAL SENSORS H. Thiele, H.-J. Friemel RADIS GmbH, Johanniskirchen, Germany Abstract: The newly available digital sensors for radiographic inspection are suitable
More informationRadiographic testing: Increased detection sensitivity using optimum source to object distance
18 th World Conference on Non destructive Testing, 16-20 April 2012, Durban, South Africa Radiographic testing: Increased detection sensitivity using optimum source to object distance Jan Hendrik COWAN
More informationPERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY
12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY Rajashekar
More informationON THE WAY TO DIGITAL RADIOGRAPHY
The 14 th International Conference of the Slovenian Society for Non-Destructive Testing»Application of Contemporary Non-Destructive Testing in Engineering«September 4-6, 2017, Bernardin, Slovenia More
More informationExperiences of users in Digital Radiography
Computed Radiography Products & Applications Experiences of users in Digital Radiography Jimmy Opdekamp May Jimmy 2006Opdekamp Global Product Manager CR Int l Workshop Imaging NDT Chennai, 25-28 April
More informationMoving from film to digital: A study of digital x-ray benefits, challenges and best practices
Moving from film to digital: A study of digital x-ray benefits, challenges and best practices H.U. Pöhler 1 and N. D Ademo 2 DÜRR NDT GmbH & Co. KG, Höpfigheimer Straße 22, Bietigheim-Bissingen, 74321,
More informationFilm Replacement in Radiographic Weld Inspection The New ISO Standard
BAM Berlin Film Replacement in Radiographic Weld Inspection The New ISO Standard 17636-2 Uwe Ewert, Uwe Zscherpel, Mirko Jechow Requests and information to: uwez@bam.de 1 Outline - The 3 essential parameters
More informationDIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.
DIGITAL RADIOGRAPHY Digital radiography is a film-less technology used to record radiographic images. 1 The purpose of digital imaging is to generate images that can be used in the diagnosis and assessment
More informationHardware for High Energy Applications 30 October 2009
Paper No. 003 09 Hardware for High Energy Applications 30 October 2009 This document was created by the Federal Working Group on Industrial Digital Radiography. Reproduction is authorized. Federal Working
More informationAPPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES
APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES Davi F. OLIVEIRA, Edson V. MOREIRA, Aline S. S. SILVA, José M. B. RABELLO, Ricardo T. LOPES, Marcelo S. PEREIRA, Uwe ZSCHERPEL
More informationPhoton Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications
19 th World Conference on Non-Destructive Testing 2016 Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications David WALTER 1, Uwe ZSCHERPEL 1, Uwe EWERT 1 1 BAM Bundesanstalt
More informationComputed Radiography
BAM Berlin Computed Radiography --INDE 2007, Kalpakkam, India -- Uwe Zscherpel, Uwe Ewert BAM Berlin, Division VIII.3 Requests Requests and and information information to: to: Dr. Dr. U. U. Zscherpel Zscherpel
More informationA COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16394 A COMPARATIVE STUDY ON THE PERFORMANCE
More informationThe HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012
The HOIS recommended practice for in-service computed radiography of pipes WCNDT 2012, Durban, SA. April 2012 Dr Stephen F Burch, ESR Technology, Oxfordshire,UK steve.burch@esrtechnology.com ESR Technology
More informationUNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY
UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY A DISCUSSION REGARDING THE CURRENT STATE OF THE TECHNOLOGY AND THE REASONS BEHIND THE SLOW TRANSITION FROM FILM
More informationPerformance evaluation of a photon counting detector for high energy NDT applications
Performance evaluation of a photon counting detector for high energy NDT applications More info about this article: http://www.ndt.net/?id=22842 Abstract Angela Peterzol 1, Pascal Brun 1, Charlotte Eriksson
More informationISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film
INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés
More informationDigital Radiology with Photon Counting Detectors
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Digital Radiology with Photon Counting Detectors More Info at Open Access Database www.ndt.net/?id=16709
More informationPRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY
19 th World Conference on Non-Destructive Testing 2016 PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY Steven MANGO 1 1 Carestream
More informationExamination of Pipe Welds by Image Plate Based Computed Radiography System
Examination of Pipe Welds by Image Plate Based Computed Radiography System Sanjoy Das, M.S.Rana, Benny Sebastian, D. Mukherjee and K.K. Abdulla Atomic Fuels Division Bhabha Atomic Research Centre Mumbai
More informationTomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams
ECNDT 2006 - We.3.2.3 Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams Bernhard REDMER, Uwe EWERT Federal Institute of Materials Research and Testing (BAM),
More informationWelding Inspection Non-Destructive Testing Course Reference WIS 5
Welding Inspection Non-Destructive Testing Course Reference WIS 5 Non Destructive Testing A welding inspector should have a working knowledge of NDT methods and their applications, advantages and disadvantages.
More informationAmorphous Selenium Direct Radiography for Industrial Imaging
DGZfP Proceedings BB 67-CD Paper 22 Computerized Tomography for Industrial Applications and Image Processing in Radiology March 15-17, 1999, Berlin, Germany Amorphous Selenium Direct Radiography for Industrial
More informationPre Conference Workshop on Advanced Digital imaging
Pre Conference Workshop on Advanced Digital imaging Uwe Zscherpel, uwez@bam.de BAM Federal Institute for Materials Research and Testing, Division 8.3 Radiological Methods, Berlin, Germany 1 Content: 1.
More informationMinimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations
uwe.ewert@bam.de Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations Uwe Ewert and Uwe Zscherpel BAM Federal Institute for
More informationMultiple Choice Identify the letter of the choice that best completes the statement or answers the question.
RA110 test 3 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. An object 35 cm in width is radiographed at 100 cm SID and at a 50 cm SOD. What
More information» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique
Recommended Techniques» There are many possible techniques for making good radiographs using CR» Following a defined procedure will simplify technique development and shorten the time to a good image»
More information17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Real-time Radiographic Non-destructive Inspection for Aircraft Maintenance Xin Wang 1, B. Stephen Wong 1, Chen Guan Tui
More informationCR Basics and FAQ. Overview. Historical Perspective
Page: 1 of 6 CR Basics and FAQ Overview Computed Radiography is a term used to describe a system that electronically records a radiographic image. Computed Radiographic systems use unique image receptors
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 16371-1 First edition 2011-10-01 Non-destructive testing Industrial computed radiography with storage phosphor imaging plates Part 1: Classification of systems Essais non destructifs
More informationEssential Parameters and Conditions for Optimum Image Quality in Digital Radiology
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology Uwe EWERT, Uwe ZSCHERPEL, Mirko
More informationLatest Developments for Pipeline Girth Welds using 3D Imaging Techniques. Novel Construction Meeting Jan van der Ent March 2016, Geneva
Latest Developments for Pipeline Girth Welds using 3D Imaging Techniques Novel Construction Meeting Jan van der Ent March 2016, Geneva 1 Content of presentation Standard A(UT) inspection What do we expect
More informationIntroduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image
Introduction Chapter 16 Diagnostic Radiology Radiation Dosimetry I Text: H.E Johns and J.R. Cunningham, The physics of radiology, 4 th ed. http://www.utoledo.edu/med/depts/radther In diagnostic radiology
More informationX-rays in medical diagnostics
X-rays in medical diagnostics S.Dolanski Babić 2017/18. History W.C.Röntgen (1845-1923) discovered a new type of radiation Nature, Jan. 23. 1896.; Science, Feb.14. 1896. X- rays: Induced the ionization
More informationRadiographic Testing (RT) [10]
Radiographic Testing (RT) [10] Definition: An NDT method that utilizes x-rays or gamma radiation to detect discontinuities in materials, and to present their images on recording medium. 1> Electromagnetic
More informationISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors
INTERNATIONAL STANDARD ISO 17636-2 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors Contrôle non destructif des
More informationComputed Radiography of Resistance Temperature Sensor for Indian PHWR
National Seminar & Exhibition on Non-Destructive Evaluation, NDE 2014, Pune, December 4-6, 2014 (NDE-India 2014) Vol.20 No.6 (June 2015) - The e-journal of Nondestructive Testing - ISSN 1435-4934 www.ndt.net/?id=17831
More informationMigrating from traditional to Digital Radiography in Aerospace
Migrating from traditional to Digital Radiography in Aerospace More info about this article: http://www.ndt.net/?id=22663 Abstract Lennart Schulenburg VisiConsult X-ray System & Solutions GmbH Brandenbrooker
More informationEssential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography
7 th European-American Workshop on Reliability of NDE Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography Uwe EWERT, Uwe ZSCHERPEL, Justus VOGEL, Fangzhou ZHANG
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés
More informationRay Detection Digital Image Quality and Influential Factors
7th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Ray Detection Digital Image Quality and Influential Factors Xiangzhao ZENG (Qingyuan, Guangdong, China Guangdong Yingquan
More informationDigital Radiography for the Inspection of Small Defects
ECNDT 2006 - Th.3.2.3 Digital Radiography for the Inspection of Small Defects Bruce Blakeley, TWI, Cambridge, UK Konstantinos Spartiotis, Ajat, Espoo, Finland Abstract. Digital Radiography offers several
More informationRecommended Training Curriculum For Digital Radiography Personnel (Level II)
Paper No. 005-11 Recommended Training Curriculum For Digital Radiography Personnel (Level II) 1 December 2011 This document was created by the Federal Working Group on Industrial Digital Radiography. Reproduction
More informationHIGH SPEED, HIGH RESOLUTION AND LOW COST DIGITAL RADIOGRAPHY
HIGH SPEED, HIGH RESOLUTION AND LOW COST DIGITAL RADIOGRAPHY AND COMPUTED TOMOGRAPHY SYSTEM Kasiviswanathan Rangarajan1,2 and T. Jensen 1 Department of Computer Engineering 2 Center for Nondestructive
More informationOverview. Corrosion detection improvement of oil and gas pipelines with industrial radiography method by using image processing.
detection improvement of oil and gas pipelines with industrial radiography method by using image processing Alireza Karimian (Engineering faculty of Isfahan university, Isfahan,, Iran ) Sepideh Yazdani
More informationTHE CR SPECIALISTS HD-CR CR 35 NDT
THE CR SPECIALISTS HD-CR CR 35 NDT COMPUTED RADIOGRAPHY SYSTEMS Digital Intelligence Ready to Change. www.duerr-ndt.com VERSATILE AND DEPENDABLE HIGH-TECH MADE IN GERMANY Highest resolution DÜRR NDT is
More informationThe HOIS recommended practice for in-service computed radiography of pipes
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa The HOIS recommended practice for in-service computed radiography of pipes Stephen F. BURCH, ESR Technology Ltd 16
More informationAdvanced Digital Radiography for Field NDT
International Symposium on Digital Industrial Radiology and Computed Tomography - We.2.3 Advanced Digital Radiography for Field NDT Ron PINCU, Ofra KLEINBERGER-RIEDRICH Vidisco Ltd. 32 Haharoshet Street,
More informationNON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS
19 th World Conference on Non-Destructive Testing 2016 NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS Brian S. WHITE 1 1 Carestream NDT, 1049 Ridge Road West, Rochester,
More informationVisibility of Detail
Visibility of Detail Radiographic Quality Quality radiographic images represents the, and information is for diagnosis. The of the anatomic structures and the accuracy of their ( ) determine the overall
More informationSECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS
RADT 3463 - COMPUTERIZED IMAGING Section I: Chapter 2 RADT 3463 Computerized Imaging 1 SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS RADT 3463 COMPUTERIZED IMAGING Section I: Chapter 2 RADT
More informationDACON INSPECTION SERVICES. Computed RADIOGRAPHY
CR Computed RADIOGRAPHY Who we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400 personnel including more than 300 inspectors
More informationAdvancements In Digital Radiography: CR, DR, and DICONDE
Advancements In Digital Radiography: CR, DR, and DICONDE Leo BOIY and Rick CUSCINO, GE Sensing & Inspection Technologies, Berchem, Belgium and Lewistown, USA Introduction Imaging in today s digital age
More informationThe field deployable digital X-Ray solution for weld inspection in O&G
The field deployable digital X-Ray solution for weld inspection in O&G Imagination at work. Haitham Ibrahim, Hanley Thomas, Steven Wissels 7 th MENDT Conference Bahrain Agenda Field inspection Actual weld
More informationX-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto
X-ray Imaging PHYS Lecture Carlos Vinhais Departamento de Física Instituto Superior de Engenharia do Porto cav@isep.ipp.pt Overview Projection Radiography Anode Angle Focal Spot Magnification Blurring
More informationScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 69 ( 2014 ) 1216 1224 24th DAAAM International Symposium on Intelligent Manufacturing and Automation, 2013 Evaluation of Pipe
More informationX-RAY COMPUTED TOMOGRAPHY
X-RAY COMPUTED TOMOGRAPHY Bc. Jan Kratochvíla Czech Technical University in Prague Faculty of Nuclear Sciences and Physical Engineering Abstract Computed tomography is a powerful tool for imaging the inner
More informationDetermination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes
More info about this article: http://www.ndt.net/?id=21129 Determination of Optimum X-Ray Tube Output Parameters kv and for Digital Radiography Testing of Welded Tubes AyazJhanorwala, SatishTilva, L &
More informationHigh Energy Digital Radiography & 3D-CT for Industrial Systems
DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France High Energy Digital Radiography & 3D-CT for Industrial Systems Non-Destructive
More informationISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded
INTERNATIONAL STANDARD ISO 17636 First edition 2003-09-15 Non-destructive testing of welds Radiographic testing of fusionwelded joints Contrôle non destructif des assemblages soudés Contrôle par radiographie
More informationPhilip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.
A new generation of x-ray computed tomography devices for quality inspection and metrology inspection in the field of additive manufacturing and other sciences Philip Sperling Sales Science and New Materials,
More informationRadionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM
Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM Preamplifiers and amplifiers The current from PMT must be further amplified before it can be processed and counted (the number of electrons yielded
More informationPhotomultiplier Tube
Nuclear Medicine Uses a device known as a Gamma Camera. Also known as a Scintillation or Anger Camera. Detects the release of gamma rays from Radionuclide. The radionuclide can be injected, inhaled or
More information10/3/2012. Study Harder
This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura Study Harder CR detection is inefficient, inferior to film screen
More informationMobile digital radiography system for nondestructive testing of large diameter pipelines
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Mobile digital radiography system for nondestructive testing of large diameter pipelines Vasily A. KLIMENOV, Aleksey
More information10/26/2015. Study Harder
This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura Study Harder CR detection is inefficient, inferior to film screen
More informationCT parameter studies for porous metal samples. Sören R. Lindemann Daimler AG Werk Untertürkheim
CT parameter studies for porous metal samples Sören R. Lindemann Daimler AG Werk Untertürkheim Where do we stand and what are we looking for? small material samples (high absorption coefficient, low porosity)
More informationDigital Imaging CT & MR
Digital Imaging CT & MR January 22, 2008 Digital Radiography, CT and MRI generate images in a digital format What is a Digital Image? A digital image is made up of picture elements, pixels row by column
More informationbrief history of photography foveon X3 imager technology description
brief history of photography foveon X3 imager technology description imaging technology 30,000 BC chauvet-pont-d arc pinhole camera principle first described by Aristotle fourth century B.C. oldest known
More informationfrom ocean to cloud The Global Marine Systems Digital Xray Camera (DXr1)
The Global Marine Systems Digital Xray Camera (DXr1) Craig Beech (Global Marine Systems Ltd), Keith Spicer (Global Marine Systems Ltd), Keith Moxey (JME Limited) craig.beech@globalmarinesystems.com Global
More informationRadiographic sensitivity improved by optimized high resolution X -ray detector design.
DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France Radiographic sensitivity improved by optimized high resolution X -ray detector
More informationDigital Detector Array Image Quality for Various GOS Scintillators
Digital Detector Array Image Quality for Various GOS Scintillators More info about this article: http://www.ndt.net/?id=22768 Brian S. White 1, Mark E. Shafer 2, William H. Russel 3, Eric Fallet 4, Jacques
More informationPart 3: Image quality classes
INTERNATIONAL STANDARD ISO 19232-3 Second edition 2013-06-15 Non-destructive testing Image quality of radiographs Part 3: Image quality classes Essais non destructifs Qualité d image des radiogrammes Partie
More informationGamex CR 2.0 Program description and operating manual
Gamex CR 2.0 Program description and operating manual Issue No. : 2.0 Date of Issue : Jan. 2013 Z.U.T. NDT SOFT http://www.ndtsoft.eu Copyright (c) 2013 by Z.U.T. NDT SOFT All Rights Reserved Disclaimer
More informationMC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE
MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE A. Miceli ab, R. Thierry a, A. Flisch a, U. Sennhauser a, F. Casali b a Empa - Swiss Federal Laboratories for
More informationStrategies for Film Replacement in Radiography - a comparative study -
IV Conferencia Panamericana de END Buenos Aires Octubre 2007 Strategies for Film Replacement in Radiography - a comparative study - 1 Uwe Ewert, 1 Uwe Zscherpel, 2 Klaus Bavendiek 1 BAM-Berlin, Federal
More informationIntroduction To NDT. BY: Omid HEIDARY
Introduction To NDT BY: Omid HEIDARY NDT Methods Penetrant Testing Magnetic Particle Testing Eddy Current Testing Ultrasonic Testing Radiographic Testing Acoustic Emission Infrared Testing Visual Testing
More informationLECTURE 1 The Radiographic Image
LECTURE 1 The Radiographic Image Prepared by:- KAMARUL AMIN ABDULLAH @ ABU BAKAR UiTM Faculty of Health Sciences Medical Imaging Department 11/23/2011 KAMARUL AMIN (C) 1 Lesson Objectives At the end of
More informationAustralian Journal of Basic and Applied Sciences
AENSI Journals Australian Journal of Basic and Applied Sciences ISSN:1991-8178 Journal home page: www.ajbasweb.com Context-Based Image Segmentation of Radiography 1 W. Al-Hameed, 2 P.D. Picton, 3 Y. Mayali
More informationNOT FOR DISTRIBUTION JINST_128P_1010 v2
Pixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-rays R Aamir a, S P Lansley a, b,*, R Zainon a, M Fiederle c, A. Fauler c, D. Greiffenberg c, P H Butler a, d d, e, f, A
More informationCOMPUTED TOMOGRAPHY 1
COMPUTED TOMOGRAPHY 1 Why CT? Conventional X ray picture of a chest 2 Introduction Why CT? In a normal X-ray picture, most soft tissue doesn't show up clearly. To focus in on organs, or to examine the
More informationTowards accurate measurements with synchrotron tomography Problems and pitfalls. Robert C. Atwood. Nghia T. Vo, Michael Drakopoulos, Thomas Connolley
Towards accurate measurements with synchrotron tomography Problems and pitfalls Robert C. Atwood Nghia T. Vo, Michael Drakopoulos, Thomas Connolley Artefacts in Synchrotron X-ray Tomography Rings Rings
More informationDigital radiography: Practical advantages of Digital Radiography. Practical Advantages in image quality
Digital radiography: Digital radiography is set to become the most common form of processing radiographic images in the next 10 years. This is due to a number of practical and image quality issues. Practical
More informationTDI Imaging: An Efficient AOI and AXI Tool
TDI Imaging: An Efficient AOI and AXI Tool Yakov Bulayev Hamamatsu Corporation Bridgewater, New Jersey Abstract As a result of heightened requirements for quality, integrity and reliability of electronic
More informationAutomated Ultrasonic Inspection for Pipeline Girth Welds
Automated Ultrasonic Inspection for Pipeline Girth Welds Sebastien Rigault PipeWizard - Product Mgr. Bob Peck EMEA NDT Business Development Mgr. Pipeline Girth Weld Inspection: In the last several years
More informationPhased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2
More Info at Open Access Database www.ndt.net/?id=15156 Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2 1 GE Inspection Technologies,
More information2017 West Coast Educators Conference Orlando. Projection Geometry. 1. Review hierarchy of image qualities (amplified version):
Spatial Resolution in the Digital Age: NOTES Quinn B. Carroll, MEd, RT 2017 West Coast Educators Conference Orlando Projection Geometry 1. Review hierarchy of image qualities (amplified version): a. Maximum
More informationIBEX TECHNOLOGY APPLIED TO DIGITAL RADIOGRAPHY
WHITE PAPER: IBEX TECHNOLOGY APPLIED TO DIGITAL RADIOGRAPHY IBEX Innovations Ltd. Registered in England and Wales: 07208355 Address: Discovery 2, NETPark, William Armstrong Way, Sedgefield, UK Patents:
More informationChromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC
Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC R. Bellazzini a,b, G. Spandre a*, A. Brez a, M. Minuti a, M. Pinchera a and P. Mozzo b a INFN Pisa
More informationIQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison
IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison Dr. Matthias Purschke/ Ulf Reimer, Agfa NDT Pantak Seifert GmbH und Co. KG, Bogenstr. 4, 96 Ahrensburg,
More informationAUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS
International Workshop SMART MATERIALS, STRUCTURES & NDT in AEROSPACE Conference NDT in Canada 2011 2-4 November 2011, Montreal, Quebec, Canada AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF
More informationP a n o r a m i c a n d C e p h a l o m e t r i c X - r a y s
AN ALL AROUND PERFECT PICTURE. The perfect combination of image quality, efficiency and design. P a n o r a m i c a n d C e p h a l o m e t r i c X - r a y s Air Techniques experts in digital imaging ProVecta
More informationCartogam Real-Time Portable Gamma-Ray Imaging System
Features Complete tool for in situ cartography, saving time, cost and dose Real-time acquisition and immediate display Two dimensional gamma mapping and dose range Dose rate estimation of hot spots Excellent
More information3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development
Teaching Radiographic Technique in a Digital Imaging Paradigm Objectives 1. Discuss the historical development of digital imaging. Dawn Couch Moore, M.M.Sc., RT(R) Assistant Professor and Director Emory
More informationv tome x m microfocus CT
GE Inspection Technologies v tome x m microfocus CT Uniting premium 3D metrology and inspection with quality and speed. gemeasurement.com/ct x plore precision CT line Inspect with precision, power, and
More informationRelated topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation
Beam hardening and metal artefacts TEP Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation Principle X-ray sources produce a polychromatic spectrum
More informationPrinciples of CT scan
Related topics Detector calibration, saturation, CT acquisition, CT reconstruction Principle X-ray computed tomography consists of using X-rays that are converted to a digital signal by a detector and
More information