1 Pre Conference Workshop on Advanced Digital imaging Uwe Zscherpel, BAM Federal Institute for Materials Research and Testing, Division 8.3 Radiological Methods, Berlin, Germany 1
2 Content: 1. Measurement principle: profile measurement in image data 2. Length calibration and correct edge positions 3. Wall thickness measurement in projection radiography 4. Wall thickness measurement in penetration direction 5. Measurement of flaw dimensions in weld inspection 6. Conclusions Software: Isee! available from 2
3 1. Measurement principle: profiles in image data Three problems: a) Images have pixels, must be calibrated in length (mm) b) Radiographic images are unsharp, correct edge position? c) Monitor displays only 256 gray values, but image could contain more (e.g. 16 bit = gray values) Demo with Isee! 3
4 3. Wall thickness measurement in projection radiography classical tangential set-up of TRT: typical exposure: radiation source, Ir 192 profile line insulation pipe line film, imaging plate, or flat panel 4
5 Praktical application in the field: BASF Projection Radiography Example : distribution station film source on-site exposure, Ir 192 radiograph 5
6 Projection Radiography visual evaluation of wall thickness error sources: w - wrong density range - inaccurate edge detection (unsharpness) - wrong magnification factor 6
7 Projection Radiography PC based wall thickness measurement input exposure parameters wall thickness result table with measurement regions tangential wall thickness algorithm wall thickness deviation in measurement region 7
8 synchronous display of positions in profile and image! 8
9 Projection Radiography PC generated measurement protocol 9
10 Demonstration with Isee! and stepped pipe Ir 192 exposure CR image pipe OD 148mm steps with 2 10 mm wall thickness 10
11 Limits of Tangential Radiography (TRT): L max W L max = 2W sqrt(d a /W 1) 300 kv 200 kv Energy: L max 100 kv : 10 mm 200 kv : 30 mm 300 kv : 40 mm 400 kv : 50 mm Se-75 : 60 mm Ir-192 : 75 mm Co-60 : 120 mm 11
12 2006: Validation of wtscope, CR-Tower and Ir-192 As measurement method according to ISO BAM BASF GE S&IT 12
13 2010: BAM certification of GE S&IT Rhythm WallThickness Modul versus wtscope: 13
14 2 Standard drafts available : pren 16407: See contributions of S. Burch at the WCNDT conference 14
15 4. Wall thickness measurement in penetration direction Second pipe inspection technique: 2. Corrosion assessment from local intensity (film density) changes (Double Wall Technique, DWT) 15
16 local corrosion: wall thickness differences in penetration direction (DWT) source pipe erosion w- w detector intensity change, I attenuation law: I w = I 0 e -µ eff w µ eff - effective attenuation coefficient relative measurement: 1. Calibration: 2. Measurement: 2 step algorithm µ eff = ln ( I REF / I IQI ) / w IQI w = ln ( I REF / I MEAS ) / µ eff 16
17 DWT for local corrosion measurement At first calibration signal at measurement point signal at reference point 1. Calculation of effective attenuation coefficient µ eff known hole depth known pipe wall thickness w at reference point Result: µ eff = f(w) dep. on radiation energy and wall thickness differences 17
18 Demonstration with Isee! and stepped pipe Penetrameter function Ir 192 exposure CR image pipe OD 148mm steps with 2 10 mm wall thickness 18
19 Comparison Film / CR DWT with Ir 192: 0,06 Result of wtscope validation for CR Tower by BAM / BASF / GE S&IT effective attenuation coefficient [1/mm] 0,05 0,04 0,03 0,02 0,01 µ eff CR Film reason: scatter sensitivity! pipe wall thickness [mm] Accuracy in practice: not better than 10 % of wall thickness! 19
20 Basis: ISO Steel ISO Al 5. Measurement of flaw dimensions in welds (formerly EN 12517) NDT of welds acceptance levels for radiographic testing Part 1: Steel, Ni, Ti & alloys Part 2: Al & alloys 20
21 Extension of Isee! for flaw measurement and evaluation Interactive measurement of pore diameters Modular: Visualization of indications, interactive verification and correction 21
22 8 mm steel Clustered porosity: Evaluation of area 28mm² + 78 mm² / 1500 mm² = 7% Acceptance level 2, quality level C of EN ISO
23 Interface to Isee! via ASCII file (*.ini format) Open for external automatic flaw detection and evaluation! 23
24 PhD 2006 O. Alekseychuk, BAM : Automated crack detection, visualization by ISee! (rectangle and crack length) 24
25 2008 Moduls for automatic flaw detection Automatic Defect Detection and Identification Processor (ADDIP), collection of special image processing algorithms for analysis of industrial radiographs ADDIP developed as programming environment for easy testing of algorithms for detection and classification of flaw indications in radiographic images TU Szczecin, Poland exposure detection 25
26 6. Conclusions 1. Measurement of dimensions only on raw data and not on the displayed monitor image (LUT clipping!) 2. Suitable calibration necessary (absolute dimension for TRT, µ eff for DWT) 3. Corrosion measurement methods validated as RT measurment method acc. to ISO (measurement value AND measurement uncertainty) 4. Standards for corrosion inspection in preparation at CEN: pren part 1 (TRT) and part 2 (DWT), will go to ISO? 5. Interactive measurement of flaw dimensions in ISee! possible, evaluation according to ISO supported 6. No general automatic flaw detection algorithms available, special algorithms (porosities, elongated cracks) developed and tested, simple interface to ISee! 26
27 The End 27
Projection Radiography. application on stream
Projection Radiography application on stream common research project BASF and BAM, later with AGFA/GE IT, IT, IAEA: computer based radiographic wall wall thickness measurement contents: --basic principles
More informationFilm Replacement in Radiographic Weld Inspection The New ISO Standard
BAM Berlin Film Replacement in Radiographic Weld Inspection The New ISO Standard 17636-2 Uwe Ewert, Uwe Zscherpel, Mirko Jechow Requests and information to: uwez@bam.de 1 Outline - The 3 essential parameters
More informationComputed Radiography
BAM Berlin Computed Radiography --INDE 2007, Kalpakkam, India -- Uwe Zscherpel, Uwe Ewert BAM Berlin, Division VIII.3 Requests Requests and and information information to: to: Dr. Dr. U. U. Zscherpel Zscherpel
More informationThe HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012
The HOIS recommended practice for in-service computed radiography of pipes WCNDT 2012, Durban, SA. April 2012 Dr Stephen F Burch, ESR Technology, Oxfordshire,UK steve.burch@esrtechnology.com ESR Technology
More informationMinimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations
uwe.ewert@bam.de Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations Uwe Ewert and Uwe Zscherpel BAM Federal Institute for
More informationEssential Parameters and Conditions for Optimum Image Quality in Digital Radiology
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology Uwe EWERT, Uwe ZSCHERPEL, Mirko
More informationExperiences of users in Digital Radiography
Computed Radiography Products & Applications Experiences of users in Digital Radiography Jimmy Opdekamp May Jimmy 2006Opdekamp Global Product Manager CR Int l Workshop Imaging NDT Chennai, 25-28 April
More informationThe HOIS recommended practice for in-service computed radiography of pipes
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa The HOIS recommended practice for in-service computed radiography of pipes Stephen F. BURCH, ESR Technology Ltd 16
More informationEssential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography
7 th European-American Workshop on Reliability of NDE Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography Uwe EWERT, Uwe ZSCHERPEL, Justus VOGEL, Fangzhou ZHANG
More informationScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 69 ( 2014 ) 1216 1224 24th DAAAM International Symposium on Intelligent Manufacturing and Automation, 2013 Evaluation of Pipe
More informationStrategies for Film Replacement in Radiography - a comparative study -
IV Conferencia Panamericana de END Buenos Aires Octubre 2007 Strategies for Film Replacement in Radiography - a comparative study - 1 Uwe Ewert, 1 Uwe Zscherpel, 2 Klaus Bavendiek 1 BAM-Berlin, Federal
More information» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique
Recommended Techniques» There are many possible techniques for making good radiographs using CR» Following a defined procedure will simplify technique development and shorten the time to a good image»
More informationISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film
INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés
More informationDürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr
lndustrial Computed Radiography with storage phosphor imaging plates results of a classification of the system Dürr HD-CR 35 NDT scanner with blue HD- IP Plus imaging plates (HD-IP + ) BAM reference BAM
More informationAPPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES
APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES Davi F. OLIVEIRA, Edson V. MOREIRA, Aline S. S. SILVA, José M. B. RABELLO, Ricardo T. LOPES, Marcelo S. PEREIRA, Uwe ZSCHERPEL
More informationPERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY
12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY Rajashekar
More informationDürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr
Industrial Computed Radiography with storage phosphor imaging plates results of a classification of the system Dürr HD-CR 35 NDT Plus scanner using HD-IP Plus imaging plates (HD-IP + ) BAM reference BAM
More informationAdvanced Digital Radiography for Field NDT
International Symposium on Digital Industrial Radiology and Computed Tomography - We.2.3 Advanced Digital Radiography for Field NDT Ron PINCU, Ofra KLEINBERGER-RIEDRICH Vidisco Ltd. 32 Haharoshet Street,
More informationA COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16394 A COMPARATIVE STUDY ON THE PERFORMANCE
More informationFig.2: Scanner VistaScan for image plates
RADIOGRAPHIC INSPECTION OF WELDINGS BY DIGITAL SENSORS H. Thiele, H.-J. Friemel RADIS GmbH, Johanniskirchen, Germany Abstract: The newly available digital sensors for radiographic inspection are suitable
More informationDigital Radiology with Photon Counting Detectors
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Digital Radiology with Photon Counting Detectors More Info at Open Access Database www.ndt.net/?id=16709
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés
More informationPart 3: Image quality classes
INTERNATIONAL STANDARD ISO 19232-3 Second edition 2013-06-15 Non-destructive testing Image quality of radiographs Part 3: Image quality classes Essais non destructifs Qualité d image des radiogrammes Partie
More informationMinimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations
More Info at Open Access Database www.ndt.net/?id=16708 Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations Uwe EWERT, Uwe
More informationDOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER
14.03.2016 DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS Bernhard REDMER Digital Technology and Networking Imaging Plates Scanner for Imaging Plates Data Transmission Reporting Computed Radiography
More informationISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors
INTERNATIONAL STANDARD ISO 17636-2 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors Contrôle non destructif des
More informationEquivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers
Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers More info about this article: http://www.ndt.net/?id=22782 Abstract
More informationDigital Radiographic Inspection replacing traditional RT and 3D RT Development
Digital Radiographic Inspection replacing traditional RT and 3D RT Development Iploca Novel Construction Meeting 27&28 March 2014 Geneva By Jan van der Ent Technical Authority International Contents Introduction
More informationRadiographic testing: Increased detection sensitivity using optimum source to object distance
18 th World Conference on Non destructive Testing, 16-20 April 2012, Durban, South Africa Radiographic testing: Increased detection sensitivity using optimum source to object distance Jan Hendrik COWAN
More informationMoving from film to digital: A study of digital x-ray benefits, challenges and best practices
Moving from film to digital: A study of digital x-ray benefits, challenges and best practices H.U. Pöhler 1 and N. D Ademo 2 DÜRR NDT GmbH & Co. KG, Höpfigheimer Straße 22, Bietigheim-Bissingen, 74321,
More informationInvestigation of the film Kodak MX 125 in Agfa NDT S eco processing
Investigation of the film Kodak MX 125 in Agfa NDT S eco processing Test Report-No.: BAM VIII.3 / 6568b Date: 26. 10. 2005 Name and address Kodak GmbH, of the customer: Hedelfinger Straße 60, 70327 Stuttgart,
More informationDigital Profile Radiography Practical uses and limitations
Digital Profile Radiography Practical uses and limitations Mr. Neil Young Asset Reliability Inspections Bunbury, Australia www.ari.com.au neil.young@ari.com.au Introduction Profile digital radiography
More information17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Real-time Radiographic Non-destructive Inspection for Aircraft Maintenance Xin Wang 1, B. Stephen Wong 1, Chen Guan Tui
More informationGamex Lite 3.0 Program description and operating manual
Gamex Lite 3.0 Program description and operating manual Issue No. : 3.0 Date of Issue : 12-2013 Z.U.T. NDT SOFT http://www.ndtsoft.eu Copyright (c) 2013 by Z.U.T. NDT SOFT All Rights Reserved Disclaimer
More information5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico
QUALIFICATION PROCESS AND INSPECTION VALIDATION OF COMPUTED RADIOGRAPHY TECHNIQUE FOR DWDI WELD INSPECTION Carla Alves MARINHO 1, José Maurício RABELLO, Marcos AIUB, Eduardo IGUCHI, Ricardo LOPES 2, Davi
More informationA Modified Detectability Criterion for Conventional Radiography Simulation
19 th World Conference on Non-Destructive Testing 2016 A Modified Detectability Criterion for Conventional Radiography Simulation David TISSEUR 1, Caroline VIENNE 1, Pierre GUÉRIN 2, Angela PETERZOL PARMENTIER
More informationDigital Profile Radiography Practical uses and limitations
More info ab Digital Profile Radiography Practical uses and limitations Mr. Neil Young Asset Reliability Inspections Bunbury, Australia www.ari.com.au neil.young@ari.com.au Introduction Profile digital
More informationTomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams
ECNDT 2006 - We.3.2.3 Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams Bernhard REDMER, Uwe EWERT Federal Institute of Materials Research and Testing (BAM),
More informationPerformance evaluation of a photon counting detector for high energy NDT applications
Performance evaluation of a photon counting detector for high energy NDT applications More info about this article: http://www.ndt.net/?id=22842 Abstract Angela Peterzol 1, Pascal Brun 1, Charlotte Eriksson
More informationExamination of Pipe Welds by Image Plate Based Computed Radiography System
Examination of Pipe Welds by Image Plate Based Computed Radiography System Sanjoy Das, M.S.Rana, Benny Sebastian, D. Mukherjee and K.K. Abdulla Atomic Fuels Division Bhabha Atomic Research Centre Mumbai
More informationON THE WAY TO DIGITAL RADIOGRAPHY
The 14 th International Conference of the Slovenian Society for Non-Destructive Testing»Application of Contemporary Non-Destructive Testing in Engineering«September 4-6, 2017, Bernardin, Slovenia More
More informationNDT KONFERANSEN ZENOVIEA VOROSCIUC
NDT KONFERANSEN 2011 ZENOVIEA VOROSCIUC Short about FMC Expectations Requirements New Challenges. New Solutions. 2 FMC Technologies Subsea Eastern ~ 150% growth from 2004-2010 MUSD Revenue Employees ER
More informationAmorphous Selenium Direct Radiography for Industrial Imaging
DGZfP Proceedings BB 67-CD Paper 22 Computerized Tomography for Industrial Applications and Image Processing in Radiology March 15-17, 1999, Berlin, Germany Amorphous Selenium Direct Radiography for Industrial
More informationPhased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2
More Info at Open Access Database www.ndt.net/?id=15156 Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2 1 GE Inspection Technologies,
More informationResearch Article Digital Radiography Using Digital Detector Arrays Fulfills Critical Applications for Offshore Pipelines
Hindawi Publishing Corporation Volume 2010, Article ID 894643, 7 pages doi:10.1155/2010/894643 Research Article Digital Radiography Using Digital Detector Arrays Fulfills Critical Applications for Offshore
More informationUser manual for the measuring program IC.exe ISee!
User manual for the page 1 of 40 BAM User manual for the measuring program IC.exe ISee! This software allows the computer-aided analysis of digital radiographs via measurements of profiles, wall thickness
More informationPRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY
19 th World Conference on Non-Destructive Testing 2016 PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY Steven MANGO 1 1 Carestream
More informationMigrating from traditional to Digital Radiography in Aerospace
Migrating from traditional to Digital Radiography in Aerospace More info about this article: http://www.ndt.net/?id=22663 Abstract Lennart Schulenburg VisiConsult X-ray System & Solutions GmbH Brandenbrooker
More informationWelding Inspection Non-Destructive Testing Course Reference WIS 5
Welding Inspection Non-Destructive Testing Course Reference WIS 5 Non Destructive Testing A welding inspector should have a working knowledge of NDT methods and their applications, advantages and disadvantages.
More informationSpokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales
Spokane Industries Computed Radiography Implementation Experience David Jolin Technical Sales djolin@spokaneindustries.com Outline Background Our Decision for Computed Radiography Implementation of CR
More informationIQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison
IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison Dr. Matthias Purschke/ Ulf Reimer, Agfa NDT Pantak Seifert GmbH und Co. KG, Bogenstr. 4, 96 Ahrensburg,
More informationOverview. Optimization of Industrial Radiography Technique for Defect Detection of Oil and Gas Pipelines in Weld Regions by Image Processing
Optimization of Industrial Radiography Technique for Defect Detection of Oil and Gas Pipelines in Weld Regions by Image Processing Alireza karimian (University of Isfahan- Isfahan - Iran) Monir Torabian
More informationISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded
INTERNATIONAL STANDARD ISO 17636 First edition 2003-09-15 Non-destructive testing of welds Radiographic testing of fusionwelded joints Contrôle non destructif des assemblages soudés Contrôle par radiographie
More informationPhoton Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications
19 th World Conference on Non-Destructive Testing 2016 Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications David WALTER 1, Uwe ZSCHERPEL 1, Uwe EWERT 1 1 BAM Bundesanstalt
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 16371-1 First edition 2011-10-01 Non-destructive testing Industrial computed radiography with storage phosphor imaging plates Part 1: Classification of systems Essais non destructifs
More informationEngineering Policy & Procedure
FPD > Engineering > Global Standards Engineering Policy & Procedure Revision History Number: G2-4 Section: G Subject: Radiographic Examination Procedure 1.0 SCOPE This procedure specifies the requirements
More informationThe field deployable digital X-Ray solution for weld inspection in O&G
The field deployable digital X-Ray solution for weld inspection in O&G Imagination at work. Haitham Ibrahim, Hanley Thomas, Steven Wissels 7 th MENDT Conference Bahrain Agenda Field inspection Actual weld
More informationTHE CR SPECIALISTS HD-CR CR 35 NDT
THE CR SPECIALISTS HD-CR CR 35 NDT COMPUTED RADIOGRAPHY SYSTEMS Digital Intelligence Ready to Change. www.duerr-ndt.com VERSATILE AND DEPENDABLE HIGH-TECH MADE IN GERMANY Highest resolution DÜRR NDT is
More informationDetermination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes
More info about this article: http://www.ndt.net/?id=21129 Determination of Optimum X-Ray Tube Output Parameters kv and for Digital Radiography Testing of Welded Tubes AyazJhanorwala, SatishTilva, L &
More informationPreliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography
ECNDT 26 - Poster 17 Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography Khairul Anuar MOHD SALLEH, Ab. Razak HAMZAH and Mohd Ashhar
More informationRay Detection Digital Image Quality and Influential Factors
7th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Ray Detection Digital Image Quality and Influential Factors Xiangzhao ZENG (Qingyuan, Guangdong, China Guangdong Yingquan
More informationInvestigation of the film FUJIFILM IX 80 in TETENAL machine processing
Investigation of the film FUJIFILM IX 80 in TETENAL machine processing Test Report No.: BAM 8.3 / 7315 d Date: 03. 02. 2012 Name and address: TETENAL AG & CO. KG Schützenwall 31-35 22844 Norderstedt Investigation:
More informationNON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS
19 th World Conference on Non-Destructive Testing 2016 NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS Brian S. WHITE 1 1 Carestream NDT, 1049 Ridge Road West, Rochester,
More informationGamex CR 2.0 Program description and operating manual
Gamex CR 2.0 Program description and operating manual Issue No. : 2.0 Date of Issue : Jan. 2013 Z.U.T. NDT SOFT http://www.ndtsoft.eu Copyright (c) 2013 by Z.U.T. NDT SOFT All Rights Reserved Disclaimer
More informationDigital Radiography for the Inspection of Small Defects
ECNDT 2006 - Th.3.2.3 Digital Radiography for the Inspection of Small Defects Bruce Blakeley, TWI, Cambridge, UK Konstantinos Spartiotis, Ajat, Espoo, Finland Abstract. Digital Radiography offers several
More informationFirst Validation of CIVA RT Module with a Linear Accelerator in a Nuclear Context
19 th World Conference on Non-Destructive Testing 2016 First Validation of CIVA RT Module with a Linear Accelerator in a Nuclear Context D. TISSEUR 1, Bernard RATTONI 1, Caroline VIENNE 1, Ronan GUILLAMET
More informationIn-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing
ISO 2016 All rights reserved ISO/TC 85/SC 6 N 230 Date: 2017-01-12 ISO/CD 20890-6:2016(E) ISO/TC 85/SC 6/WG 3 Secretariat: ANSI In-service inspections for primary coolant circuit components of light water
More informationAustralian Journal of Basic and Applied Sciences
AENSI Journals Australian Journal of Basic and Applied Sciences ISSN:1991-8178 Journal home page: www.ajbasweb.com Context-Based Image Segmentation of Radiography 1 W. Al-Hameed, 2 P.D. Picton, 3 Y. Mayali
More informationOverview. Corrosion detection improvement of oil and gas pipelines with industrial radiography method by using image processing.
detection improvement of oil and gas pipelines with industrial radiography method by using image processing Alireza Karimian (Engineering faculty of Isfahan university, Isfahan,, Iran ) Sepideh Yazdani
More informationAdvancements In Digital Radiography: CR, DR, and DICONDE
Advancements In Digital Radiography: CR, DR, and DICONDE Leo BOIY and Rick CUSCINO, GE Sensing & Inspection Technologies, Berchem, Belgium and Lewistown, USA Introduction Imaging in today s digital age
More informationExposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?
Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them? Definition and Validation of Exposure Indices Ingrid Reiser, PhD DABR Department of Radiology University of Chicago
More informationDigital Radiography Systems Techniques and Performance Evaluation for Space Applications
172 Digital Radiography Systems Techniques and Performance Evaluation for Space Applications V.N. Misale, S. Ravi and R. Narayan Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation
More informationFlash-Radiography Instead of Traditional Radiography with Intermediate Carriers of Information
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16577 Flash-Radiography Instead of Traditional
More informationUNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY
UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY A DISCUSSION REGARDING THE CURRENT STATE OF THE TECHNOLOGY AND THE REASONS BEHIND THE SLOW TRANSITION FROM FILM
More informationIntroduction To NDT. BY: Omid HEIDARY
Introduction To NDT BY: Omid HEIDARY NDT Methods Penetrant Testing Magnetic Particle Testing Eddy Current Testing Ultrasonic Testing Radiographic Testing Acoustic Emission Infrared Testing Visual Testing
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 12096 First edition 1996-05-01 Submerged arc-welded steel tubes for pressure purposes - Radiographit testing of the weld seam for the detection of imperfections Tubes en acier
More informationVisibility of Detail
Visibility of Detail Radiographic Quality Quality radiographic images represents the, and information is for diagnosis. The of the anatomic structures and the accuracy of their ( ) determine the overall
More informationApplication Report 11/15/5471 Company: Kienle Spiess
11/15/5471 Company: Kienle Spiess Birger Niehaus, 12/07/2015 Radioscopic (DR) Inspection and Computer Tomography (CT) of Squirrel-Cage Motors Technology with Passion System description MU 2000-D CT X-ray
More informationDigital Radiography : Flat Panel
Digital Radiography : Flat Panel Flat panels performances & operation How does it work? - what is a sensor? - ideal sensor Flat panels limits and solutions - offset calibration - gain calibration - non
More informationSINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011
SINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011 Automated Defect Recognition Software for Radiographic and Magnetic Particle Inspection B. Stephen Wong 1, Xin Wang 2*,
More informationCOMPUTED RADIOGRAPHY THE STATE OF THE ART
2007 International Nuclear Atlantic Conference - INAC 2007 Santos, SP, Brazil, September 30 to October 5, 2007 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-02-1 COMPUTED RADIOGRAPHY
More informationFully Automated Inspection of Welded Seams with a New High Resolution Durable X-ray Camera System
ECNDT 2006 - Tu.2.4.4 Fully Automated Inspection of Welded Seams with a New High Resolution Durable X-ray Camera System Thomas WENZEL, Rolf BEHRENDT, Theobald FUCHS, Ulrich HÜTTEN, Günther KOSTKA, Peter
More informationFlat Panel Detectors in Industrial Radiography
1. INTRODUCTION Flat Panel Detectors in Industrial Radiography P.R. Vaidya, Ph.D. Head, Quality Control Section Quality Assurance Division Bhabha Atomic Research Centre Bombay 400 085, India. pr_vaidya@yahoo.com
More informationA True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR
A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY Series 4 CR Fujifilm, the absolute pioneer in digitized medical X-ray imaging advanced into the industrial inspection field
More informationNew Developments in Automated Inspection for Corrosion under Insulation
ECNDT 2006 - Mo.2.5.5 New Developments in Automated Inspection for Corrosion under Insulation John RUDLIN, TWI Limited, Cambridge, UK Abstract - Detection of corrosion under insulation (CUI) has been a
More informationNON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I
NON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I 1.What do you mean by Non-Destructive Testing (NDT)? Inspecting or testing the materials and components in such a way that allows the materials
More informationUNDERSTANDING THE CHALLENGES IN THE TRANSITION FROM FILM TO DIGITAL RADIOGRAPHY IN THE NUCLEAR POWER INDUSTRY
UNDERSTANDING THE CHALLENGES IN THE TRANSITION FROM FILM TO DIGITAL RADIOGRAPHY IN THE NUCLEAR POWER INDUSTRY RM Meyer *, P Ramuhalli *, TL Moran *, CA Nove, and AF Pardini * U.S. Nuclear Regulatory Commission,
More informationAustralian Standard RADIOGRAPHY OF WELDED BUTT JOINTS IN METAL. Part 2 IMAGE QUALITY INDICATORS (IQI) AND RECOMMENDATIONS FOR THEIR USE
AS 2177, Part 2 1982 Australian Standard RADIOGRAPHY OF WELDED BUTT JOINTS IN METAL Part 2 IMAGE QUALITY INDICATORS (IQI) AND RECOMMENDATIONS FOR THEIR USE This standard, prepared by Committee MT/7, Non-destructive
More informationA TUTORIAL FOR PERFORMING A RADIOGRAPHIC EXAMINATION
AD AD-E403 864 Technical Report AREIS-TR-16011 A TUTORIAL FOR PERFORMING A RADIOGRAPHIC EXAMINATION Stephan Zuber March 2017 U.S. ARMY ARMAMENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER Enterprise and
More informationDigital Radiography and its Advantages in Field NDT Inspections Today
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Digital Radiography and its Advantages in Field NDT Inspections Today Ron PINCU NDT Division Manager, Vidisco Ltd. 32 Haharoshet
More informationMULTI-CHANNEL ULTRASONIC FLAW DETECTOR ОКО-22М-UT THE BEST INDUSTRIAL OEM SOLUTION FOR IN-LINE AND IN-SERVICE SYSTEMS
MULTI-CHANNEL ULTRASONIC FLAW DETECTOR ОКО-22М-UT THE BEST INDUSTRIAL OEM SOLUTION FOR IN-LINE AND IN-SERVICE SYSTEMS www.ndt.com.ua PURPOSE OKO-22M-UT PRO WIRELESS INTERFACE WI-FI The ОКО-22М-UT ultrasonic
More informationRadiation Protection and On-Site Inspection of the Elevated Subway Construction with an Ir-192 Gamma-Source
Radiation Protection and On-Site Inspection of the Elevated Subway Construction with an Ir-192 Gamma-Source Bernhard Redmer, Stefan Hohendorf, Falk Hille BAM Berlin Abstract To proof the integrity of riveted
More informationNDE Technology of Pressure Equipment in Line with International Standards
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China NDE Technology of Pressure Equipment in Line with International Standards Part 1:Radiographic Examination Yan LI Jiangsu
More informationNDT Supply.com P.O. BOX 7350 Shawnee Mission, KS USA SIUI Digital Ultrasonic Flaw Detector
Full featured, Portable, Easy-to-Use & Reliable New Generation General-Purpose Digital Flaw Detector Portable, Easy-to-Use, Reliable Advanced General-Purpose Digital Flaw Detector Adjustable spike & square
More informationRADIOGRAPHIC EXPOSURE
RADIOGRAPHIC EXPOSURE Receptor Exposure Receptor Exposure the that interacts with the receptor. Computed Radiography ( ) requires a. Direct Digital Radiography (DR) requires a. Exposure Indicators Exposure
More informationAUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS
International Workshop SMART MATERIALS, STRUCTURES & NDT in AEROSPACE Conference NDT in Canada 2011 2-4 November 2011, Montreal, Quebec, Canada AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF
More informationHalf value layer and AEC receptor dose compliance survey in Estonia
Half value layer and AEC receptor dose compliance survey in Estonia K. Kepler, A. Vladimirov Training Centre of Medical Physics, University of Tartu Testing Centre of the University of Tartu, Estonia E-mail:
More informationCOMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY
COMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY MY1204107 Noorhazleena Azaman, Khairul Anuar Mohd Salleh, Sapizah Rahim, Shaharudin Sayuti, Arshad Yassin, Ab. Razak Hamzah Non
More informationNDT-PRO Services expands service offering
NDT-PRO Services expands service offering NDT-PRO Services announced the formal release of two advanced NDT methods, Phased Array (including TOFD) and Eddy Current. What are they and where are the used?
More informationNEW POSSIBILITIES OF RADIATION CONTROL OF QUALITY OF WELDED JOINTS
NDT of Welded Joints NEW POSSIBILITIES OF RADIATION CONTROL OF QUALITY OF WELDED JOINTS V.A. TROITSKY E.O. Paton Electric Welding Institute, NASU 11 Bozhenko Str., 03680, Kiev, Ukraine. E-mail: office@paton.kiev.ua
More information