Investigation of the film FUJIFILM IX 80 in TETENAL machine processing
|
|
- Daniela O’Connor’
- 5 years ago
- Views:
Transcription
1 Investigation of the film FUJIFILM IX 80 in TETENAL machine processing Test Report No.: BAM 8.3 / 7315 d Date: Name and address: TETENAL AG & CO. KG Schützenwall Norderstedt Investigation: Measurement of the film system parameters according to EN 584-1:2006, ISO :2008 and ASTM E of the film FUJIFILM IX 80 (10x24), emulsion No E, exp. date , vacu packed with lead screens (0.027 mm front and back), film processing according to the test specification Test specification: Investigation of the film FUJIFILM IX 80 in TETENAL Roentoroll HC developer and TETENAL Superfix MRP fixer, automatic processing in AGFA NDT S machine with 8 min cycle time, immersion time 100 s, temperature 28 C Date of testing: Place of testing: BAM Berlin This test report consists of page 1 to 7 and enclosures one figure. This test report may only be published in full and without any additions. A revocable permission in writing has to be obtained from BAM for any amended reproduction of this certificate or the publication of any excerpts. The test results refer exclusively to the tested materials.
2 BAM Test Report page 2 of 7 pages BAM Ref.:8.3/7315d Aim of the investigation: Processing of the received emulsions of the mentioned non-destructive testing film FUJIFILM IX 80 in the processing chemistry TETENAL Roentoroll HC developer and TETENAL Superfix MRP fixer (processor AGFA NDT S, cycle time 8 min, immersion time 100 s, temperature 28 C) and measurement of the film system parameters gradient and granularity as well as determination of the gradient/noise ratio according to the standards EN 584-1:2006, ISO :2008 and ASTM E Test Program: 1. Exposure of the films in steps of optical density with an automatic film transport unit at conditions according to the above standards. 2. Development of the films. 3. Measurement of the optical density of the steps to determine the characteristic film curve and the film gradients at D-D 0 = 2.00 and D-D 0 = Measurement of the granularity at D-D 0 = Instruments for processing and measurements: The exposures of the films (packed in AGFAPACK 10x24 with 0,027 mm lead screens) were performed with the filtered (8 mm Cu) 220 kv radiation of a highly stabilized X ray facility (320 Isovolt D for dosimetry of the Seifert company) and an automated computer controlled film transport for exposure. For the measurement of the diffuse optical density a calibrated densitometer (Macbeth TD 502) was used, while the granularity was measured with a computer controlled microdensitometer of the type Joyce Loebl 3CS with an quadratic aperture of 100 m x 100 m. Film processing: For the automatic processing in the TETENAL Roentoroll HC developer (LOT , ) and TETENAL Superfix MRP fixer (LOT , ) the following parameters were observed: temperature of the developer 28 C, immersion time 100 s, cycle time of the process 8 minutes. Procedure for determination of the film system parameters according to EN 584-1:2006, ISO :2008 and ASTM E : The system parameters gradient G(2) and G(4) at the optical densities 2.00 and 4.00 above fog and base (D 0 ), the granularity D and the gradient/noise ratio G(2)/ D are determined for a film system, which comprises a film type and the processing chemistry inclusive the processing at specified parameters. In detail the following processing steps were carried out:
3 BAM Test Report page 3 of 7 pages BAM Ref.:8.3/7315d - procurement of films and processing chemicals, - preparation of the developer and fixer according to the prescriptions of the manufacturer, - stabilisation of the developer with approximately 0.1 m 2 film material - test exposure for the determination of the suitable exposure times for the steps of optical density, - exposure of at least 6 film samples for each system with filtered 220 kv radiation on at least 12 steps of optical density between D=1 and D= 4.7 in each case (see procedure in EN 584-1:2006, ISO :2008, ASTM E , - processing of the films according to the prescriptions of the manufacturer and controlling by a film test strip according to EN and ISO , - measurement of the processed films with the Macbeth densitometer and storage of the exposure data and the density values as the average of 3 measured values per density step in a file as well as the density of fog and film base, - evaluation of the data by approximation of the film curve by a third order polynomial and determination of the gradient G(2) for the density D - D 0 = 2.00 and the gradient G(4) at D - D 0 = 4.00 in accordance with EN 584-1:2006, ISO :2008 and ASTM E , - measurement of the local density fluctuations of the films at density D - D 0 = with a microdensitometer (scan length 140 mm), - calibration of the microdensitometer into diffuse optical density with the aid of a film sample of the investigated film system, - calculation of the root mean square D of the optical density after conversion of the specular density into diffuse density, a digital high pass filtering to cut off low frequency noise below 0.1 mm -1 and the determination of the median according to ISO 10505:2009 and EN 584-1:2006, - conversion of the granularity value into the corresponding value for measurements with a circular aperture with a diameter of 100 m, - correction of the granularity value on the basis of measured density above fog and base to D - D 0 = 2.00, - calculation of the average of the relevant data from at least 6 film samples. Results: The diffuse density of fog and film base results in: D 0 = 0.21 The characteristic curve of the films shows up to the density 4.5 above fog and base the usual shape. Under the given conditions the exposed dose for density 2 above fog and base amounts to:
4 BAM Test Report page 4 of 7 pages BAM Ref.:8.3/7315d K S = ( ) mgy According to table 2 of EN 584-1:2006 this corresponds to a CEN speed of: S = 160 The values of the gradients determined under the given conditions amount to: G (2) = G (4) = The granularity D at density D - D 0 = 2.00 results in: D = The gradient/noise ratio is calculated to: G(2) / D = 179 According to table 1 of EN 584-1:2006 the limiting values for the film system class C4 amount to: G (2) 4.1, G (4) 6.8, D 0.028, G/(2)/ D 150 The film system consisting of emulsion No E of the non-destructive testing film FUJIFILM IX 80 in the processing chemistry TETENAL Roentoroll HC developer and TETENAL Superfix MRP fixer (automatic processing AGFA NDT S machine, cycle time 8 min, immersion time 100 s, temperature 28 C), meets the requirements of the film system class C4 of the standards EN 584-1:2006 and ISO :2008 and system class I of ASTM E The values and its standard deviations mentioned above were determined from the respective values of the gradients and the granularity at the given densities (D - D 0 = 2.00 and D - D 0 = 4.00) from 6 film samples (trimmed mean). The plots in the added graph (page 6, optical density (above fog and base) and gradient) result from the average of 8 film curves measured on 8 different film samples of the emulsion. The certified FUJIFILM PMC pre-exposed control strips (batch 84843, emulsion No E, exp. date ) according to EN and ISO provide the following indices (as reference values the values for FUJIFILM HUNT AUDEL developer and FUJIFILM HUNT AUFIX fixer at am immersion time of 100 s (8 min cycle) and a developer temperature of 27 C were used):. S x = 1.95 (- 10 %) compared to S r = 2.19 and C x = 1.41 (+28 %) compared to C r = 1.1.
5 BAM Test Report page 5 of 7 pages BAM Ref.:8.3/7315d The certified FUJIFILM process monitor strips indicate deviations larger than 10 % from the certified values, which indicates that the investigated chemistry and development conditions are outside the specification (see EN 584-1:2006). But this behaviour was already observed before for other mixed systems and is typically for FUJIFILM PMC stripes. The certified AGFA PMC pre-exposed control strips (batch C075, emulsion No , exp. date ) according to EN and ISO provide the following indices (as reference values the certified values for AGFA G135 developer and AGFA G335 fixer at an immersion time of 100s (8 min cycle) and a developer temperature of 28 C were used): S x = 1.96 (± 0 %) compared to S r =1.96 and C x = 1.35 (+2.3 %) compared to C r = The certified AGFA process monitor strips indicate no deviations larger than 10 % from the certified values, which indicates that the investigated chemistry and development conditions are within the specification (see EN 584-1:2006). Finally, the Agfa Structurix Thio-Test was performed to estimate the archivability of the processed films. The evaluation of the results according to ISO results in: L.E. = 100 (colour of the light step indicating a Life Expectancy of 100 years)
6 BAM Test Report page 6 of 7 pages BAM Ref.:8.3/7315d Remark: This report summarizes only the results of the measurements at a single emulsion and is valid only for this special emulsion; especially it states no general classification of a film system. For a system classification corresponding to EN 584-1:2006 a continuous measurement of all films of all manufactured emulsions by an independent third party is necessary, or, the continuous own product control in the house of the manufacturer in connection with the participation in a proficiency test according to EN 584-1:2006 for the harmonisation of the measuring procedures and algorithms and sample test measurements by an independent third party. BAM Federal Institute for Materials Research and Testing BAM Bundesanstalt für Materialforschung und prüfung Division 8.3 Nondestructive Testing - Radiological Methods D Berlin, on behalf on behalf Prof. Dr. U. Ewert Dr. rer. nat. U. Zscherpel BAM division 8.3 is an accredited testing laboratory by Deutsche Akkreditierungsstelle GmbH (DAkkS) against DIN EN ISO/IEC The accreditation is valid for the testing procedures listed in the certificate D-PL D-PL
7 BAM Test Report page 7 of 7 pages BAM Ref.:8.3/7315d Density and Gradient Dose (mgray) opt. Density BAM 12-04
Investigation of the film Kodak MX 125 in Agfa NDT S eco processing
Investigation of the film Kodak MX 125 in Agfa NDT S eco processing Test Report-No.: BAM VIII.3 / 6568b Date: 26. 10. 2005 Name and address Kodak GmbH, of the customer: Hedelfinger Straße 60, 70327 Stuttgart,
More informationGB/T Translated English of Chinese Standard: GB/T
Translated English of Chinese Standard: GB/T19348.1-2014 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 37.040.25; 19.100 J 04 GB/T 19348.1-2014
More informationDürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr
Industrial Computed Radiography with storage phosphor imaging plates results of a classification of the system Dürr HD-CR 35 NDT Plus scanner using HD-IP Plus imaging plates (HD-IP + ) BAM reference BAM
More informationComputed Radiography
BAM Berlin Computed Radiography --INDE 2007, Kalpakkam, India -- Uwe Zscherpel, Uwe Ewert BAM Berlin, Division VIII.3 Requests Requests and and information information to: to: Dr. Dr. U. U. Zscherpel Zscherpel
More informationDürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr
lndustrial Computed Radiography with storage phosphor imaging plates results of a classification of the system Dürr HD-CR 35 NDT scanner with blue HD- IP Plus imaging plates (HD-IP + ) BAM reference BAM
More informationExperiences of users in Digital Radiography
Computed Radiography Products & Applications Experiences of users in Digital Radiography Jimmy Opdekamp May Jimmy 2006Opdekamp Global Product Manager CR Int l Workshop Imaging NDT Chennai, 25-28 April
More informationFilm Replacement in Radiographic Weld Inspection The New ISO Standard
BAM Berlin Film Replacement in Radiographic Weld Inspection The New ISO Standard 17636-2 Uwe Ewert, Uwe Zscherpel, Mirko Jechow Requests and information to: uwez@bam.de 1 Outline - The 3 essential parameters
More informationMinimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations
uwe.ewert@bam.de Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations Uwe Ewert and Uwe Zscherpel BAM Federal Institute for
More informationStrategies for Film Replacement in Radiography - a comparative study -
IV Conferencia Panamericana de END Buenos Aires Octubre 2007 Strategies for Film Replacement in Radiography - a comparative study - 1 Uwe Ewert, 1 Uwe Zscherpel, 2 Klaus Bavendiek 1 BAM-Berlin, Federal
More informationEssential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography
7 th European-American Workshop on Reliability of NDE Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography Uwe EWERT, Uwe ZSCHERPEL, Justus VOGEL, Fangzhou ZHANG
More informationPre Conference Workshop on Advanced Digital imaging
Pre Conference Workshop on Advanced Digital imaging Uwe Zscherpel, uwez@bam.de BAM Federal Institute for Materials Research and Testing, Division 8.3 Radiological Methods, Berlin, Germany 1 Content: 1.
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 16371-1 First edition 2011-10-01 Non-destructive testing Industrial computed radiography with storage phosphor imaging plates Part 1: Classification of systems Essais non destructifs
More informationMoving from film to digital: A study of digital x-ray benefits, challenges and best practices
Moving from film to digital: A study of digital x-ray benefits, challenges and best practices H.U. Pöhler 1 and N. D Ademo 2 DÜRR NDT GmbH & Co. KG, Höpfigheimer Straße 22, Bietigheim-Bissingen, 74321,
More informationISO INTERNATIONAL STANDARD. Photography Root mean square granularity of photographic films Method of measurement
INTERNATIONAL STANDARD ISO 10505 First edition 2009-05-15 Photography Root mean square granularity of photographic films Method of measurement Photographie Moyenne quadratique granulaire de films photographiques
More informationISO INTERNATIONAL STANDARD. Photography Root mean square granularity of photographic films Method of measurement
INTERNATIONAL STANDARD ISO 10505 First edition 2009-05-15 Photography Root mean square granularity of photographic films Method of measurement Photographie Moyenne quadratique granulaire de films photographiques
More informationEssential Parameters and Conditions for Optimum Image Quality in Digital Radiology
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology Uwe EWERT, Uwe ZSCHERPEL, Mirko
More informationIntroduction of a Single Chip TLD System for Patient Dosimetry
Introduction of a Single Chip TLD System for Patient Dosimetry C. Hranitzky a, M. Halda a, G. Müller a, B. Obryk b, H. Stadtmann a* a Austrian Research Centers GmbH ARC, 2444 Seibersdorf, Austria. b Institute
More informationPro Chem Tetenal photo chemistry.
www.tetenal.com 2016 Pro Chem Tetenal photo chemistry. Tetenal Professional Chemicals Tetenal chemicals offer the highest possible processing quality, user-friendliness and cost-effectiveness. They allow
More informationA COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16394 A COMPARATIVE STUDY ON THE PERFORMANCE
More informationFOMA NDT SYSTEM X-Ray films for industrial radiography INDUX and FOMADUX Processing chemicals Представляем новинки shrinkage mark CD4
www.foma.eu Представляем новинки elongated/worm hole porosity shrinkage mark CD4 FOMA NDT SYSTEM X-Ray films for industrial radiography INDUX and FOMADUX Processing chemicals FILMS FOR INDUSTRIAL RADIOGRAPHY
More information5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico
QUALIFICATION PROCESS AND INSPECTION VALIDATION OF COMPUTED RADIOGRAPHY TECHNIQUE FOR DWDI WELD INSPECTION Carla Alves MARINHO 1, José Maurício RABELLO, Marcos AIUB, Eduardo IGUCHI, Ricardo LOPES 2, Davi
More informationA Modified Detectability Criterion for Conventional Radiography Simulation
19 th World Conference on Non-Destructive Testing 2016 A Modified Detectability Criterion for Conventional Radiography Simulation David TISSEUR 1, Caroline VIENNE 1, Pierre GUÉRIN 2, Angela PETERZOL PARMENTIER
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 11699-1 Second edition 2008-09-15 Non-destructive testing Industrial radiographic film Part 1: Classification of film systems for industrial radiography Essais non destructifs
More informationKODAK Panchromatic Separation Film 2238
TECHNICAL INFORMATION DATA SHEET Copyright, Eastman Kodak Company, 2015 KODAK Panchromatic Separation Film 2238 1) Description KODAK Panchromatic Separation Film 2238 is a black-and-white film intended
More informationKODAK Medical X-ray Film / General Purpose / Blue / 3528 / MXB
TECHNICAL INFORMATION DATA SHEET Copyright, Eastman Kodak Company, 1998 KODAK Medical X-ray Film / General Purpose / Blue / 3528 / MXB 1) Description KODAK Medical X-ray Film / General Purpose / Blue /
More informationEquivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers
Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers More info about this article: http://www.ndt.net/?id=22782 Abstract
More informationKODAK Simulation Film / 7157
TECHNICAL INFORMATION DATA SHEET Copyright, Eastman Kodak Company, 1998 1) Description KODAK Simulation Film / 7157 KODAK Simulation Film / 7157 is a high-speed, wide latitude, orthochromatic medical x-ray
More informationKODAK X-OMAT BT Film / 4530 / XBT
TECHNICAL INFORMATION DATA SHEET Copyright, Eastman Kodak Company, 2003 KODAK X-OMAT BT Film / 4530 / XBT 1) Description KODAK X-OMAT BT Film / 4530 is a full-speed, blue-sensitive medical x-ray screen
More informationA Guide to Radiochromic Film Dosimetry with EBT2 and EBT3
A Guide to Radiochromic Film Dosimetry with EBT2 and EBT3 David F. Lewis Advanced Materials Group Ashland Specialty Ingredients Spain, April 2014 What is Radiochromic Film? A film that instantly changes
More informationA panchromatic negative film for aerial photography.
AVIPHOT PAN 80 A panchromatic negative film for aerial photography. Aviphot Pan 80 PE0 is a panchromatic aerial negative high resolution film, coated onto a transparent polyester base providing excellent
More informationFire testing: Calibration of smoke opacity measuring systems
Subject of Agreement EGOLF AGREEMENT 002-2016 Calibration of smoke opacity measuring systems Related test standard EN 13823 Date of issue Reference original query SM3:1996 Previous publication number (if
More informationGE Sensing & Inspection Technologies. X-Ray Radiographic Film Systems
GE Sensing & Inspection Technologies X-Ray Radiographic Film Systems GE Sensing & Inspection Technologies A global leader in technology-driven inspection solutions that deliver productivity, quality and
More informationGamex Lite 3.0 Program description and operating manual
Gamex Lite 3.0 Program description and operating manual Issue No. : 3.0 Date of Issue : 12-2013 Z.U.T. NDT SOFT http://www.ndtsoft.eu Copyright (c) 2013 by Z.U.T. NDT SOFT All Rights Reserved Disclaimer
More informationM. Senoner 1), Th. Wirth 1), W. E. S. Unger 1), M. Escher 2), N. Weber 2), D. Funnemann 3) and B. Krömker 3) INTRODUCTION
Testing of Lateral Resolution in the Nanometre Range Using the BAM-L002 - Certified Reference Material: Application to ToF-SIMS IV and NanoESCA Instruments M. Senoner 1), Th. Wirth 1), W. E. S. Unger 1),
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 14096-1 First edition 2005-06-15 Non-destructive testing Qualification of radiographic film digitisation systems Part 1: Definitions, quantitative measurements of image quality
More informationCertified Reference Material
Bundesanstalt für Materialforschung und -prüfung (BAM) in co-operation with the Committee of Chemists of the GDMB Gesellschaft der Metallurgen und Bergleute e.v. Element Certified Reference Material BAM-M376a
More informationProcess Monitoring: Sensitometric Parameters
Process Monitoring: Sensitometric Parameters Revised 7/04 In addition to monitoring the key chemical and mechanical process parameters and processing KODAK Audit Strips, Process E-6, you should continue
More informationState of the Art Film Dosimetry
State of the Art Film Dosimetry Micke A., Lewis D. Advanced Materials Ashland proprietary technology, patents pending Film Dosimetry Radiochromic Film EBT2/EBT3 One-Scan Protocol Multi-channel Film Dosimetry
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés
More informationCOMPUTED RADIOGRAPHY THE STATE OF THE ART
2007 International Nuclear Atlantic Conference - INAC 2007 Santos, SP, Brazil, September 30 to October 5, 2007 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-02-1 COMPUTED RADIOGRAPHY
More informationHeiland electronic GmbH TD / TD1 / TD2. B&W-Densitometers. USERS MANUAL Version 5
Heiland electronic GmbH TD / TD1 / TD2 B&W-Densitometers USERS MANUAL Version 5 2 Table of Contents 1. GENERAL INFORMATION...4 2. SAFETY REGULATIONS...5 3. AREA OF APPLICATIONS...5 4. INSTRUMENT DESCRIPTION...6
More informationISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film
INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés
More informationNDT Supply.com 7952 Nieman Road Lenexa, KS USA
Durr NDT ScanX Computed Radiography System The Workhorse of Portable Digital Radiography in NDT There are 2 models available: ScanX Discover HR ScanX Discover HC ScanX Discover HR ScanX Discover HC The
More informationThe Influence of Film Processing Temperature and Time on Mammographic film Characteristics
ffi;j*hjh[;~, 8: -9, 997 Bull Seh Health Sci, Okayama Univ (Original) The Influence of Film Processing Temperature and Time on Mammographic film Characteristics Toshinori MARUYAMA, Sachiko GOTO, Yoshiharu
More informationAF3-024E COLOR REVERSAL FILMS 1. FEATURES AND USES 2. SPEED
AF3-024E COLOR REVERSAL FILMS FUJICHROME 64T TYPE II Professional [RTPII] 1. FEATURES AND USES FUJICHROME 64T TYPE II Professional [RTP II] is an ISO 64 speed tungsten-type high image quality color reversal
More information:AVIPHOT COLOR N400 PE1
:AVIPHOT COLOR N400 PE1 Panchromatic Negative Colour Film :Aviphot Color N400 PE1 is a panchromatic negative colour film, designed for aerial photography from low to medium altitudes. This film gives excellent
More informationFUJICHROME PROVIA 1600 Professional [RSP]
AF3-798E COLOR REVERSAL FILMS FUJICHROME PROVIA 1600 Professional [RSP] 1 FEATURES AND USES FUJICHROME PROVIA 1600 Professional [RSP] is an ultra-high speed daylight-type color reversal film designed for
More informationMinimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations
More Info at Open Access Database www.ndt.net/?id=16708 Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations Uwe EWERT, Uwe
More informationGE Measurement & Control. X-Ray
GE Measurement & Control X-Ray Radiographic Film Systems s GE Measurement & Control A global leader in technology-driven inspection solutions that deliver productivity, quality and safety to our customers.
More informationZHM CT Series. Technical Datasheet. Gear Flow Meters in Cartridge Design for paint applications, optimized with regard to flushing and to weight
www.kem-kueppers.com Technical Datasheet ZM CT Series Gear Flow Meters in Cartridge Design for paint applications, optimized with regard to flushing and to weight Certified zertifiziert according gemäß
More informationCamera Negative Microfilm Data Sheet
Camera Negative Microfilm Data Sheet KODAK IMAGELINK HQ, CS, CP and FS Microfilms Description Kodak Imagelink Microfilms have been specially designed to produce high-quality images from a wide variety
More informationEASTMAN EXR 200T Film 5287, 7287
TECHNICAL INFORMATION DATA SHEET TI2124 Issued 6-94 Copyright, Eastman Kodak Company, 1994 EASTMAN EXR 200T Film 5287, 7287 1) Description EASTMAN EXR 200T Film 5287 (35 mm) and 7287 (16 mm) is a medium-high
More informationA panchromatic negative film for aerial photography.
AVIPHOT PAN 80 A panchromatic negative film for aerial photography. Aviphot Pan 80 PE0 is a panchromatic aerial negative high resolution film, coated onto a transparent polyester base providing excellent
More informationRF-EXPOSURE ASSESSMENT REPORT
RF-EXPOSURE ASSESSMENT REPORT EN 62311 RF-Exposure evaluation of electronic equipment Report Reference No.... : G0M-1206-2043-TEU311E-V01 Testing Laboratory... : Address... : Storkower Str. 38c 15526 Reichenwalde
More informationAVITONE PD 1 P-OS AND PD 3 P-OS
AVITONE PD 1 P-OS AND PD 3 P-OS Orthochromatic continuous tone, direct positive copying film Avitone PD 1 p-os and PD 3 p-os are orthochromatic, continuous tone, direct positive copying films, coated on
More informationEASTMAN EXR 500T Film 5298
TECHNICAL INFORMATION DATA SHEET TI2082 Revised 12-98 Copyright, Eastman Kodak Company, 1993 1) Description EASTMAN EXR 500T Films 5298 (35 mm) is a high-speed tungsten-balanced color negative camera film
More informationUsing KODAK Control Strips for Processes AR-5 and AN-6
Using KODAK Control Strips for Processes AR-5 and AN-6 TECHNICAL DATA / CHEMICAL March 2010 TI-2220 INTRODUCTION This information is excerpted from a section on control strips in the process manual entitled
More informationAPPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES
APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES Davi F. OLIVEIRA, Edson V. MOREIRA, Aline S. S. SILVA, José M. B. RABELLO, Ricardo T. LOPES, Marcelo S. PEREIRA, Uwe ZSCHERPEL
More informationDRAWINGS ON 35mm MICROFILM INSPECTION PROCEDURES SILVER MICROFILM
AT& T PRACTICE AT& T 006-110-500 Standard Issue 6, March 1987 DRAWINGS ON 35mm MICROFILM INSPECTION PROCEDURES SILVER MICROFILM 1. GENERAL 1.01 This practice covers inspection procedures for 35mm silver
More informationGAFCHROMIC HD-810 Radiochromic Dosimetry Film Configuration, Specifications and Performance Data
GAFCHROMIC HD-810 Radiochromic Dosimetry Film Configuration, Specifications and Performance Data Description GAFCHROMIC HD-810 dosimetry film is designed for the measurement of absorbed dose of high-energy
More informationHeiland electronic GmbH TRD 2. B&W-Densitometer. User manual Version 6.4
Heiland electronic GmbH TRD 2 B&W-Densitometer User manual Version 6.4 Table of Contents 1. GENERAL INFORMATION... 3 2. SAFETY REGULATIONS... 3 3. AREA OF APPLICATIONS... 3 4. INSTRUMENT DESCRIPTION 4.1.
More informationDigital Quality Control Phantom for X-ray Mammography Image
Digital Quality Control Phantom for X-ray Mammography Image Yuichi Nagai, Atsuko Takada National: Cancer Hospital East Department of Radiology Collaborated by Nobuyuki Niwa : Kyoto Kagaku Co., Ltd. Introduction
More informationKODAK VISION Expression 500T Color Negative Film / 5284, 7284
TECHNICAL INFORMATION DATA SHEET TI2556 Issued 01-01 Copyright, Eastman Kodak Company, 2000 1) Description is a high-speed tungsten-balanced color negative camera film with color saturation and low contrast
More informationCertified Reference Material
Certified Reference Material BAM-F012 (brief excerpt) Glass-based Multi-emitter Fluorescence Standard as day-to-day intensity and wavelength standard for instrument performance validation (IPV) of fluorescence
More informationNEW POSSIBILITIES OF RADIATION CONTROL OF QUALITY OF WELDED JOINTS
NDT of Welded Joints NEW POSSIBILITIES OF RADIATION CONTROL OF QUALITY OF WELDED JOINTS V.A. TROITSKY E.O. Paton Electric Welding Institute, NASU 11 Bozhenko Str., 03680, Kiev, Ukraine. E-mail: office@paton.kiev.ua
More informationNDE SOLUTIONS RADIOGRAPHY COURSE OUTLINE
NDE SOLUTIONS RADIOGRAPHY COURSE OUTLINE 80 Hour Course Length 1.0 NDT Qualification and Introduction (3 Hours) 1.1 NDT Introduction 1.2 NDT Qualification and Certification 1.2.1 NAS 410 1.2.2 SNT-TC-1A
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-18175-01-03 according to DIN EN ISOIEC 17025:2005 Period of validity: 01.07.2016 to 10.11.2019 Holder of certificate: Nemko
More informationAVIPHOT ASP 400 S PE1/PE0
AVIPHOT ASP 400 S PE1/PE0 Panchromatic negative B/W film for traffic infringement camera ASP 400 S is a panchromatic halftone aerial negative film with near IR sensitivity. The emulsion is coated onto
More informationHalf value layer and AEC receptor dose compliance survey in Estonia
Half value layer and AEC receptor dose compliance survey in Estonia K. Kepler, A. Vladimirov Training Centre of Medical Physics, University of Tartu Testing Centre of the University of Tartu, Estonia E-mail:
More informationTechnical Data Range of AgfaPhoto standard films
Technical Data Range of AgfaPhoto standard films -1 Vista 100 Vista 200 Vista 400 APS star 200 CTprecisa 100 400 500 This brochure contains information on the quality and features of AgfaPhoto amateur
More informationCompliance Guidance for RADIOGRAPHIC QUALITY CONTROL (5 th Edition)
Compliance Guidance for RADIOGRAPHIC QUALITY CONTROL (5 th Edition) New Jersey Department of Environmental Protection Bureau of X-ray Compliance PO Box 420 Mail Code 25-01 Trenton, NJ 08625-0420 FAX 609-984-5811
More informationISO Photography Intra-oral dental radiographic film and film packets Manufacturer specifications
INTERNATIONAL STANDARD ISO 35 Third edition 2011-09-01 Photography Intra-oral dental radiographic film and film packets Manufacturer specifications Photographie Film et paquets de films pour la radiographie
More informationNDT-PRO Services expands service offering
NDT-PRO Services expands service offering NDT-PRO Services announced the formal release of two advanced NDT methods, Phased Array (including TOFD) and Eddy Current. What are they and where are the used?
More informationThe advantages of variable contrast
Contrast Control with Color Enlargers Calibration of dichroic heads to ISO paper grades -an- by Ralph W. Lambrecht The advantages of variable contrast paper over graded paper have made it the prime choice
More informationMEASURING CONDITIONS AND UNCERTAINTIES FOR THE COMPARISON AND CALIBRATION OF NATIONAL DOSIMETRIC STANDARDS AT THE BIPM *
MEASURING CONDITIONS AND UNCERTAINTIES FOR THE COMPARISON AND CALIBRATION OF NATIONAL DOSIMETRIC STANDARDS AT THE BIPM * C. Kessler and D.T. Burns December 2018 BUREAU INTERNATIONAL DES POIDS ET MESURES
More informationRADIOGRAPHIC EXAMINATION PROCEDURE
Page 1 of 19 Doc. No. KNS/RT/01.REV 0 RADIOGRAPHIC EXAMINATION PROCEDURE Page: 19 of 19 Date: 15.09.2012 RADIOGRAPHIC EXAMINATION PROCEDURE PREPARED & APPROVED BY NDE- Level III CERTIFIED BY REVIEWED BY
More informationIn-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing
ISO 2016 All rights reserved ISO/TC 85/SC 6 N 230 Date: 2017-01-12 ISO/CD 20890-6:2016(E) ISO/TC 85/SC 6/WG 3 Secretariat: ANSI In-service inspections for primary coolant circuit components of light water
More informationImage Evaluation and Analysis of Ink Jet Printing System (I) MTF Measurement and Analysis of Ink Jet Images
IS&T's 2 PICS Conference Image Evaluation and Analysis of Ink Jet Printing System (I) ment and Analysis of Ink Jet Images C. Koopipat*, M. Fujino**, K. Miyata*, H. Haneishi*, and Y. Miyake* * Graduate
More informationKODAK MIN-R S Film / 4906
TECHNICAL INFORMATION DATA SHEET Copyright, Eastman Kodak Company, 2002 KODAK MIN-R S Film / 4906 1) Description KODAK MIN-R S Film / 4906 is a medium speed, dual coated, ortho-sensitive medical x-ray
More informationFUJICOLOR NPC 160 PROFESSIONAL [NPC]
AF3-065E COLOR NEGATIVE FILMS FUJICOLOR NPC 160 PROFESSIONAL [NPC] 1. FEATURES AND USES FUJICOLOR NPC 160 PROFESSIONAL [NPC] is an ISO 160 daylight color negative film that is suitable for highcontrast
More informationA panchromatic negative film for technical, industrial and aerial photography
:AVIPHOT PAN 200 A panchromatic negative film for technical, industrial and aerial photography :Aviphot Pan 200 PE1 is a panchromatic negative film, coated onto a transparent polyester base providing excellent
More informationBurning Test on Battery
Geschäftsführer: Prof. Dr.-Ing. Wilhelm Hanel Tel.: +49 351 8837-322 Fax: +49 351 8804313 Hausadresse: Wilhelmine-Reichard-Ring 4 01109 Dresden Postfachadresse: Postfach 80 01 44 01101 Dresden Test Report
More informationKODAK AEROCHROME III MS Film 2427
AS-2569 KODAK AEROCHROME III MS Film 2427 KODAK AEROCHROME III MS Film 2427 is a very fine-grain, medium-speed color-reversal aerial camera film. This film has excellent color rendition and good image
More informationEASTMAN TRI-X Reversal Film 7278
MPTVI Data Sheet XXXXXXXXXXX XX KODAK XX XX TInet XX XXXXXXXXXXX Technical Information Copyright, Eastman Kodak Company, 1994 1) Description EASTMAN TRI-X Reversal Film 7278 EASTMAN TRI-X Reversal Film
More informationDetermination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes
More info about this article: http://www.ndt.net/?id=21129 Determination of Optimum X-Ray Tube Output Parameters kv and for Digital Radiography Testing of Welded Tubes AyazJhanorwala, SatishTilva, L &
More informationPhoton Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications
19 th World Conference on Non-Destructive Testing 2016 Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications David WALTER 1, Uwe ZSCHERPEL 1, Uwe EWERT 1 1 BAM Bundesanstalt
More informationAnatomix Plus X-Ray System
T E C H N I C A L I N F O S H E E T Anatomix Plus X-Ray System I. SYSTEM DESCRIPTION Anatomix Plus liquid concentrates are formulated for use in all automatic processing machines for all standard cycle
More informationEASTMAN EXR 200T Film / 5293, 7293
TECHNICAL INFORMATION DATA SHEET Copyright, Eastman Kodak Company, 2003 1) Description EASTMAN EXR 200T Film / 5293 (35 mm), 7293 (16 mm) is a medium- to high-speed tungsten-balanced color negative camera
More informationKeysight Technologies Optical Power Meter Head Special Calibrations. Brochure
Keysight Technologies Optical Power Meter Head Special Calibrations Brochure Introduction The test and measurement equipment you select and maintain in your production and qualification setups is one of
More informationX-Ray Radiographic Film Systems
GE Sensing & Inspection Technologies X-Ray Radiographic Film Systems GEIT-40007EN_Filmbroch.indd 1 14-10-2008 11:42:03 GE Sensing & Inspection Technologies A global leader in technology-driven inspection
More informationIncreasing the Sensitivity of Ultrasonic Phased Array Wheel Set Axle Inspection by Using Signal Processing
ESIS TC24 Workshop: Integrity of Railway Structures Increasing the Sensitivity of Ultrasonic Phased Array Wheel Set Axle Inspection by Using Signal Processing Thomas HECKEL 1, Rainer BOEHM 1, Wolfgang
More informationMinilab Compendium. Data and Product Information
POTO IMAGING INK JET PREPRESS MEDICAL IMAGING Minilab Compendium and Product Information Quickfinder compactline Cartridges Colorprint 1500 for Kis PhotoMe Processes for Fuji Minilabs Processes for Agfa
More informationLight) Conditions. Lens Aperture Shutter Speed (sec.) NOTES. Light. Conditions. Lens Aperture Shutter Speed (sec.) None LBB-12** (or Wratten No.
AF3-074E COLOR NEGATIVE FILMS (ADVANCED PHOTO SYSTEM FILM) 1. FEATURES AND USES FUJICOLOR nexia 800 is an Advanced Photo System daylight color negative film with an ISO speed rating of 800. It adopts a
More information1 MPTVI DATA SHEET XXXXXXXXXXX
1 MPTVI DATA SHEET XXXXXXXXXXX TI1664 XX KODAK XX Reissued 6-92 XX TInet XX XXXXXXXXXXX ================================================================== TECHNICAL INFORMATION Copyright, Eastman Kodak
More informationDocuments and Addresses
Report No.: 14-041-MS Sheet: 2 Documents and Addresses Accreditation The Prüffeld der Schaltwerke, Berlin has been approved by the DAkkS (German accreditation body) according to EN ISO/IEC 17025 for tests
More informationScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 69 ( 2014 ) 1216 1224 24th DAAAM International Symposium on Intelligent Manufacturing and Automation, 2013 Evaluation of Pipe
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI National Accreditation Board 11617 Coldwater Road, Fort Wayne, IN 46845 USA This is to certify that Kanawha Scales and Systems, Inc. 26 Whitney Drive Milford, OH 45150
More informationFUJIFILM Europe DIS (Direct Injection System)
FUJIFILM Europe DIS (Direct Injection System) Operation Manual 1. Description Noritsu and Gretag minilabs which are designed for Kodak SM chemicals do not have conventional replenishing tanks. Conventional
More informationISO 5-3 INTERNATIONAL STANDARD. Photography and graphic technology Density measurements Part 3: Spectral conditions
INTERNATIONAL STANDARD ISO 5-3 Third edition 2009-12-01 Photography and graphic technology Density measurements Part 3: Spectral conditions Photographie et technologie graphique Mesurages de la densité
More informationAnatomix RP X-Ray System
T E C H N I C A L I N F O S H E E T Anatomix RP X-Ray System I. SYSTEM DESCRIPTION Anatomix RP liquid concentrates are formulated for use in all automatic processing machines for all standard time cycles,
More information