EUROFINS PRODUCT SERVICE GMBH
|
|
- Arabella Gaines
- 5 years ago
- Views:
Transcription
1 EUROFINS PRODUCT SERVICE GMBH EMC TEST - REPORT TEST REPORT NUMBER: G0M E-13 Storkower Str. 38c, Reichenwalde, Phone Germany Fax
2 TABLE OF CONTENTS 1 General Information Notes Operator Testing laboratory Location Details of accreditation status Test location, if different Details of applicant Application details Test item Description of test item Manufacturer (if different from approval holder in point 1.4) Test standards 4 2 Technical test Summary of test results Test environment Test equipment utilized Testresults acc. EN /14/ Carried out emission tests Carried out immunity tests Test protocols 14 3 Normative references 19 Annex A: Pictures Annex B: Diagrams Page 1 of 4
3
4 1.3 Testing laboratory Location EUROFINS PRODUCT SERVICE GMBH STORKOWER STR. 38c D REICHENWALDE B. BERLIN GERMANY Telephone : Telefax : Details of accreditation status DAR ACCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: DAT-P-268/08 RECOGNIZED NOTIFIED BODY EMC REGISTRATION NUMBER: BNetzA-bS EMV-07/61 RECOGNIZED NOTIFIED BODY R&TTE REGISTRATION NUMBER: BNetzA-bS-02/51-53 FCC FILED TEST LABORATORY REG.-NO A2LA ACCREDITED TESTING LABORATORY CERTIFICATE NO BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) ACCREDITED BY BLUETOOTH QUALIFICATION REVIEW BOARD INDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC Test location, if different Name :./. Street :./. Town :./. Country :./. Telephone :./. Fax :./. ./. Page 3 of 6
5 1.4 Details of applicant Name : Falcom Wireless Communications GmbH Street : Gewerbering 6 Town : Langewiesen Country : Germany Telephone : Fax : ceo@falcom.de Contact : Herr Ralf Leipoldt Telephone : Application details Date of receipt of application : Date of receipt of test item : Date of test : Test item Description of test item Description of test item Type identification Serial number Voltage supply Operating Mode : GSM/GPRS/GPS tracking unit : FOX-LT-IP : without : 12 / 24 VDC : GSM-link Manufacturer (if different from approval holder in point 1.4) Name : --- Street : --- Town : --- Country : Test standards EN V EN V EN 55022: A1: 2007 Page 4 of 7
6 2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests performed. or The deviations as specified in 2.4 were ascertained in the course of the tests performed. 2.2 Test environment Temperature : 24,5 C Relative humidity content : 31 % Air pressure : 1005 hpa Page 5 of 8
7 2.3 Test equipment utilized No. Test Equipmen Type Manufacturer ETS 0001 ESD Gun SESD Schlöder ETS 0008 Antenna Loop antenna Siemens ETS 0012 Biconical Antenna HK 116 R & S ETS 0013 LPD Antenna HL 223 R & S ETS 0014 Log Periodical Antenna HL 025 R & S ETS 0038 RF amplifier 150L Amplifier Research ETS 0032 Controller HD 050 Heinrich Deisel ETS 0039 Absorbing clamp MDS 21 R & S ETS 0040 Artificial Mains Network ESH3-Z5 R & S ETS 0041 T-Artificial Mains Network ESH3-Z4 R & S ETS 0042 Artificial Mains ESH3-Z6 R & S ETS 0045 Vehicle LISN NNBM 8126D Schwarzbeck ETS 0052 Audio analyzer UPA 4 R & S ETS 0056 Ultra Compact Simulator UCS 500 M4 EM Test ETS 0057 Motor Variac MV 2616 EM Test ETS 0058 Capacitive coupling clamp E 502 B Keytek/ EMC ETS 0059 Kikusui amplifier PCR 2000L Keytek/ EMC ETS 0064 CDN IEC Keytek/ EMC ETS 0066 EM Injection Clamp FCC/ EMC ETS 0076 Feeding bridge A SBA 1000 ESP ETS 0082 PC system Esotronic ETS 0085 Shielded room SR 1 Frankonia ETS 0086 Semi-Anechoic chamber AC 1 Frankonia ETS 0088 Color TV pattern Generator PM 5518-TX VPS Philips ETS 0092 Power Amplifier 150W1000 AR Amplifier Research ETS 0102 CDN M3-801/6 MEB ETS 0103 Magnetic field test set MF1000 EMC-Partner ETS 0148 RF Current Probe F-65 FCC ETS 0155 Signal Generator SMG R & S ETS 0157 TV and Sat-Signalgenerator VTG 700 Grundig ETS 0161 Harmonic / Flicker Analyzer HFA 3000 Schlöder ETS 0178 Open area test side 10m ETS ETS 0233 Direction coupler RK 100 MEB ETS 0276 Audio Analyzer UPL 16 R & S ETS 0282 RF bridge 75 Ohm A HP ETS 0287 EMI Test receiver ESHS10 R & S ETS 0288 Artificial mains ESH2-Z5 R & S ETS 0292 RF Generator SMHU R & S ETS 0348 RF Millivolt meter URV 55 R & S ETS 0300 RF amplifier 75 A 250 Ar ETS 0348 RF Millivolt meter URV 55 R & S ETS 0401 MPEG2 Generator DVG R & S ETS 0402 TV Messender SFQ R & S ETS 0409 Stripline DC220 Schwarzbeck ETS WIRE ISN with B1 ENY41 R & S ETS 0448 RF Power Amplifier AR 60S1G3 AR Amplifier Research ETS 0472 Antenna BTA-H Frankonia ETS 0474 EMI Test Receiver ESCS 30 R&S ETS 0485 Radio Communication Tester CMU 200 R&S Page 6 of 9
8 2.4 Testresults acc. EN /14/ 1 st test test after modification production test Test Emission / Immunity Done Test passed Test failed EN /1/ clause 8.3, 8.4, 8.7 EN /1/ clause 8.2 Conducted Emission EN /13/ Radiated Emission EN /13/ EN /1/ clause 9.3 EN /1/ clause 9.2 EN /1/ clause 9.4 Electrostatic Discharge EN /2/ Radiated Immunity EN /3/ Electrical Fast Transients EN /4/ EN /1/ clause 9.8 Transients comm.& diff. mode EN /5/ EN /1/ clause 9.5 EN /1/ clause 9.7 RF continues conducted EN /6/ Voltage dips and Interruption EN /8/ EN /1/ clause 9.6 Transient and surges in vehiculars ISO /11/ ISO /12/ Comment: Page 7 of 10
9 2.4.1 Carried out emission tests Conducted Emission This test is in accordance to subclause 8.3; 8.4 and 8.7 of EN /1/. Test Equipment ETS 0040 ETS 0085 ETS 0474 Software: ES-K1, Vers. 1.6SP2 Test Procedures Test configuration The test configuration is contained inside of a shielded chamber and corresponds to the standard EN /13/. The equipment under test is placed in the facility on a wooden table 0.8 m high. The equipment under test is connected with the artificial mains network (AMN) in a distance of 0,8 m and also 0,8 m from other subassembly and metallic area. The observation of the equipment under test is realized by 3 video cameras and by a microphone. Test parameters and marginal conditions The test are carried out with a nominal impedance by 50 Ω / 50 μh of the AMN in a frequency range of 150 khz to 30 MHz. Further information please find in test report. The equipment under test fulfils the requirement in accordance with the criteria of the standard. Page 8 of 11
10 Conducted Emission according to EN Rear of EUT to flushed with rear of taple top 10 cm EUT Non-conductive table 80 cm AE 80 cm to the ground table AMN ISN 40 cm min AMN Bonded to horizontal ground plane Bonded to horizontal ground plane AMN AE EUT ISN = Artificial mains network = Associated equipment = Equipment under test = Impedance stabiliyation network Page 9 of 12
11 2.4.2 Carried out immunity tests RF Electromagnetic Field This test is in accordance to subclause 9.2 of EN /1/. Test Equipment ETS 0086 ETS 0155 ETS 0448 ETS 0472 Software: ETS RF-Field v Test Procedures Test configuration The test configuration is contained inside of a shielded chamber and corresponds to the standard EN /3/. The equipment under test is placed in the facility on a wooden table 0.8 m high on the centre axis of the chamber. The power supply and the RF connection points are close to the equipment under test at the floor of the chamber inside a connection box. The cables to this connection box are shielded and below the double floor. The transmitting antenna is placed in a height of 1.5m, in a distance of 3.0 m. The RF-generators are placed in a special room adjacent to the chamber. The observation of the equipment under test is realized by 3 video cameras and by a microphone. Test parameters and marginal conditions The tests are carried out with a field strength by 3 V/m (measured in the unmodulated field) with amplitude modulated signal by a depth of 80 % by a sinusoidal audio signal of 1 khz. The logarithmic step was 1% and the dwell time was 1s dependent of the EUT cycle time. Further information please find in test protocol. The equipment under test fulfils the requirement in accordance with the criteria of the standard. Page 10 of 13
12 RF - Field according to EN Uniform area Non-conductive table Lines < 3 m on 1 m total length, low-induction bunched Real cabling < 1 m 0,8 m Field-generating antenna Lines > 3 m or not defined Irradiated length has to be 1 m Absorber or disturbance filter Absorber elements placed as required in partly covered anechoice chambers to reduce the ground reflexion Page 11 of 14
13 Transients and Surges in vehicular enviroment These test are applicable to mobile radio and ancillary equipment intended for use in a vehicular enviroment. This test is in accordance to subclause 9.6 of EN /1/. Test equipment ETS 0244 ETS 0245 ETS 0246 Software: ISMISO 4.11 Test Procedures Test configuration The test configuration is in correspondence to the standard ISO / - 2 /11/, /12/. The test is carried out on a wooden table with a grounded metal plate on its top. The equipment under test is placed on an insulating support of 100 mm height above this metal plate. Test parameters and marginal conditions The tests are carried out are the pulses according to subclause and of EN /1/ and the special requiremnets of EN /2/ subclause The overview please find in the test protocol. Page 12 of 15
14 Transients and Surges in vehicular enviroment ISO 7637 Pulse injection (prinzipe schemata) Page 13 of 16
15 2.4.3 Test protocols Conducted emission 15 RF-Field 16 RF-common mode 17 Transients and Surges in vehicular environment 18 Page 14 of 17
16 Conducted Emission Emission Standard : EN /1/ (EN /13/) Reg. no. : G0M E-13 Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP Date : Class : B Frequency range Network Passed Failed Number of rechecks 150 khz - 30 MHz R S 0 Operating Mode: GSM-link Instrumentation uncertainty: U lab(cond) = 3.8 db Comment: See attached diagrams. Page 15 of 17
17 Radiofrequency Electromagnetic Field Immunity RF Field Standard : EN /1/ subclause 9.2 (EN /3/) Reg. no. : G0M E-13 Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP Date : Test equipment : Anechoic chamber, amplifier: ar, antenna (BTA-H) Frequency Range Voltage (RMS) Modulation Frequency Opinion MHz 3 V/m 1 khz (80 % AM) A MHz 3 V/m 1 khz (80 % AM) A Operating Mode: GSM-link Opinion: A : No loss of performance or function. B : Temporary loss of function or performance which is self-recoverable. C : Temporary loss of function or perform, which req. operat. intervention or system reset. D : Loss of function which is not recoverable. Passed: yes / no Page 16 of 17
18 Conducted Immunity RF - common mode Standard : EN /1/ subclause 9.5 (EN /6/) Reg. no. : G0M E-13 Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP Date : Test port Voltage (rms) Modulation Frequency Frequency Range Opinion 12 VDC 3 1 khz 150 khz - 80 MHz A 24 VDC 3 1 khz 150 khz - 80 MHz A Operating Mode: GSM-link Opinion: A : No loss of performance or function. B : Temporary loss of function or performance which is self-recoverable. C : Temporary loss of function or perform, which req. operat. intervention or system reset. D : Loss of function which is not recoverable. Passed: yes / no Page 17 of 17
19 Transients and surges in vehicular environment Standard : EN /1/ subclause 9.6 (ISO /-2 /11/, /12/) Reg. no. : G0M E-13 Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP Date : Testport Pulse Level ISO Test requirements Criteria DC-Power line (12V) 1 III 10 times C DC-Power line (12V) 2a III 10 times A DC-Power line (12V) 2b III 10 times C DC-Power line (12V) 3a III 20 minutes A DC-Power line (12V ) 3b III 20 minutes A DC-Power line (12V ) 4 III 10 times C Testport Pulse Level ISO Test requirements Criteria DC-Power line (24V) 1 III 10 times C DC-Power line (24V) 2a III 10 times A DC-Power line (24V) 2b III 10 times C DC-Power line (24V) 3a III 20 minutes A DC-Power line (24V ) 3b III 20 minutes A DC-Power line (24V ) 4 III 10 times C Opinion: A : No loss of performance or function. B : Temporary loss of function or performance which is self-recoverable. C : Temporary loss of function or perform. which req. operat. intervention or system reset. D : Loss of function which is not recoverable. Passed: yes / no Page 18 of 18
20 3 Normative references /1/ EN V1.8.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements /2/ EN : A1 : A2 : 2001 Electromagnetic Compatibility (EMC); Part 4: Testing and measurements techniques - Section 2: Electrostatic discharge immunity test. Basic EMC publication. /3/ EN : A1: 2008 Electromagnetic Compatibility - Basic immunity standard - Radiated, radio-frequency electromagnetic field. Immunity test. /4/ EN : 2004 Electromagnetic Compatibility (EMC); Part 4: Testing and measurements techniques - Section 4: Electrical fast transient/burst immunity test. Basic EMC publication. /5/ EN : 2007 Electromagnetic Compatibility - Basic immunity standard. Surge immunity Test. /6/ EN : 2007 Electromagnetic Compatibility - Basic immunity standard - Conducted disturbances induced by radio-frequency fields. Immunity test. /7/ EN : A1: 2001 Electromagnetic Compatibility - Testing and measurements techniques Power frequency magnetic field immunity test. /8/ EN : 2004 Electromagnetic Compatibility (EMC); Part 4: Testing and measurements techniques - Section 11: Voltage dips, short interruptions and voltage variations immunity tests - Basic EMC publication. /11/ ISO : 2002 Road vehicles - Electrical disturbance by conducting and coupling Part 1: Definitions and general /12/ ISO : A1: 2008 Road vehicles - Electrical disturbance by conducting and coupling Part 2: Vehicles with nominal 12V or 24V supply voltage Electrical transient conduction along supply lines only /13/ EN : A1: 2007 Limits and methods of measurement of radio interference characteristics of information technology equipment. /14/ EN : V1.3.1 Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS) Page 19 of 19
21 Annex A: Pictures Annex A Page 1 of 1
22 EMI voltage test in the dc-mains according to EN ORDER NO: G0M Approval Holder: Falcom Wireless Communication GmbH EUT: GSM/GPRS/GPS-tracking unit Model: FOX-LT-IP Test Site / Operator: / Mr. Klein Test Conditions: Tnom: 23 C, Unom: 13.5 VDC Test Specification: V-Network: ESH3-Z5 (L) Comment 1: mode: GSM1900 link Comment 2: mode: Level [dbµv] 150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30M Frequency [Hz] MES EN Vdc_pre PK MES EN Vdc_pre AV LIM EN V QP LIM EN V AV Voltage QP Limit Voltage AV Limit Page 1/ :36 EN Vdc Annex B Page 1/4
23 EMI voltage test in the dc-mains according to EN ORDER NO: G0M Approval Holder: Falcom Wireless Communication GmbH EUT: GSM/GPRS/GPS-tracking unit Model: FOX-LT-IP Test Site / Operator: / Mr. Klein Test Conditions: Tnom: 23 C, Unom: 13.5 VDC Test Specification: V-Network: ESH3-Z5 (N) Comment 1: mode: GSM1900 link Comment 2: mode: Level [dbµv] 150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30M Frequency [Hz] MES EN Vdc_pre PK MES EN Vdc_pre AV LIM EN V QP LIM EN V AV Voltage QP Limit Voltage AV Limit Page 1/ :24 EN Vdc Annex B Page 2/4
24 EMI voltage test in the dc-mains according to EN ORDER NO: G0M Approval Holder: Falcom Wireless Communication GmbH EUT: GSM/GPRS/GPS-tracking unit Model: FOX-LT-IP Test Site / Operator: / Mr. Klein Test Conditions: Tnom: 23 C, Unom: 27 VDC Test Specification: V-Network: ESH3-Z5 (L) Comment 1: mode: GSM1900 link Comment 2: mode: Level [dbµv] 150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30M Frequency [Hz] MES EN Vdc_pre PK MES EN Vdc_pre AV LIM EN V QP LIM EN V AV Voltage QP Limit Voltage AV Limit Page 1/ :00 EN Vdc Annex B Page 3/4
25 EMI voltage test in the dc-mains according to EN ORDER NO: G0M Approval Holder: Falcom Wireless Communication GmbH EUT: GSM/GPRS/GPS-tracking unit Model: FOX-LT-IP Test Site / Operator: / Mr. Klein Test Conditions: Tnom: 23 C, Unom: 27 VDC Test Specification: V-Network: ESH3-Z5 (N) Comment 1: mode: GSM1900 link Comment 2: mode: Level [dbµv] 150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30M Frequency [Hz] MES EN Vdc_pre PK MES EN Vdc_pre AV LIM EN V QP LIM EN V AV Voltage QP Limit Voltage AV Limit Page 1/ :49 EN Vdc Annex B Page 4/4
EUROFINS PRODUCT SERVICE GMBH
EUROFINS PRODUCT SERVICE GMBH EMC TEST - REPORT TEST REPORT NUMBER: G0M20904-2310-E-13 Storkower Str. 38c, 15526 Reichenwalde, Phone +49-33631-888 0 Germany Fax +49-33631-888 660 TABLE OF CONTENTS 1 General
More informationEUROFINS PRODUCT SERVICE GMBH FCC RULES PART 15 / SUBPART B IC RSS-GEN ISSUE 2. Test report no.: G0M E-18. Testing Cert #1983.
EUROFINS PRODUCT SERVICE GMBH TEST - REPORT FCC RULES PART 15 / SUBPART B IC RSS-GEN ISSUE 2 Test report no.: G0M20904-2310-E-18 Testing Cert #1983.01 Storkower Str. 38c, 15526 Reichenwalde, Phone +49-33631-888
More informationEUROFINS PRODUCT SERVICE GMBH. Testing Cert # FCC RULES PART 15 / SUBPART B IC RSS-GEN ISSUE 3. DECT Basestation WHB003BS
EUROFINS PRODUCT SERVICE GMBH Testing Cert #1983.1 TEST - REPORT FCC RULES PART 15 / SUBPART B IC RSS-GEN ISSUE 3 WHB3BS FCC ID: BCE-WHB3BS IC: 2386C-WHB3BS Test report no.: GM-114-192-C-1 Storkower Str.
More informationEUROFINS PRODUCT SERVICE GMBH EN V Tracking solution. Bolero-LT2
EUROFINS PRODUCT SERVICE GMBH RADIO TEST-REPORT EN 300 440 V1.4.1 Tracking solution Bolero-LT2 TEST REPORT NUMBER: G0M-1103-1037-T-42 Eurofins Product Service GmbH Storkower Str. 38c, 15526 Reichenwalde,
More informationEUROFINS PRODUCT SERVICE GMBH EN V1.6.1 EN V Asset tracker. Rock
EUROFINS PRODUCT SERVICE GMBH RADIO TEST- REPORT EN 300 440-1 V1.6.1 EN 300 440-2 V1.4.1 Asset tracker Rock TEST REPORT NUMBER: G0M-1103-1036-T-42 Eurofins Product Service GmbH Storkower Str. 38c, 15526
More informationEN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments
EMC Page 3 / 33 Test report No.: EN 61000-6-3:2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: 2013-10-16
More informationEUROFINS ETS PRODUCT SERVICE GMBH 3GPP TS GCF-CC NAPRD.03. Test report no.: G0M T-51
EUROFINS ETS PRODUCT SERVICE GMBH GSM TEST -REPORT 3GPP TS 51.010-1 GCF-CC NAPRD.03 Test report no.: G0M20807-1889-T-51 Eurofins ETS Product Service GmbH Storkower Str. 38c, 15526 Reichenwalde, Phone +49-33631-888
More informationEUROFINS PRODUCT SERVICE GMBH. FCC RULES PARTS IC RADIO STANDARDS RSS-210 Issue 7 FCC ID: UOU68981AA630D-01 IC: 1884E
EUROFINS PRODUCT SERVICE GMBH TEST - REPORT FCC RULES PARTS 15.247 IC RADIO STANDARDS RSS-210 Issue 7 FCC ID: UOU68981AA630D-01 IC: 1884E-68981000 Model Name: Aastra 630d Test report no.: G0M20811-2089-P-15
More informationOverview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University
Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted
More informationEN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass
Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz
More informationBy order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China
4317137.50 EMC Test report for LED Fixed luminaires Models LED12036-1R, LED12036-2TU, LED120363R, LED12036-4TU2, LED12036-6TR, LED12036-1R CHR, LED12036-2TU CHR, LED12036-3R CHR, LED12036-4TU2 CHR, LED12036-6TR
More informationHarmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass
Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,
More informationEMC standards. Presented by: Karim Loukil & Kaïs Siala
Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards
More informationCTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT
CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CNB3150602-00399-E 2/F., South Tower, Huoju Building, No.181, Canghai Road,
More informationEMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45
REPORT NO. PRSZ15110502E EMC TEST REPORT For Boardcon Technology Limited. MINI9G45 Computer on Module Model No. : MINI9G45 Prepared For : Boardcon Technology Limited. : Room 702, Hua Feng Xin An Business
More informationEMC Test report for LED Panel Light Models , , , , ,
4326247.50 EMC Test report for LED Panel Light Models 000529, 000530, 000531, 000532, 000535, 000536 Guangzhou, date of issue: 2016-02-24 Author:Jazz Liang By order of Marvo Verlichting B.V. at Hoogeveen,
More informationPage: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003
Page: 1 of 20 EMC TEST REPORT Reference No. Applicant : WT05060412 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Cable Standards Model No : UAS111-M, UAS111, UAS112 : EN55022:1998+A2:2003
More informationDiscontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz
Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationEMC TEST REPORT. FCC 47 CFR Part 15B Industry Canada RSS-Gen Electromagnetic compatibility - Unintentional radiators Pleasanton USA
EMC TEST REPORT FCC 47 CFR Part 15B Industry Canada RSS-Gen Electromagnetic compatibility - Unintentional radiators Report Reference No.... : G0M-1202-1776-EF01-V01 Testing Laboratory... : Address... :
More informationContent. Report No. SH Page 2 of 22
Page 2 of 22 Content SUMMARY...1 1. GENERAL INFORMATION...3 1.1 Description of Equipment Under Test (EUT)...3 1.2 Description of Client...3 1.3 Description of Test Facility...3 2. TEST SPECIFICATIONS...4
More informationTest and Measurement for EMC
Test and Measurement for EMC Bogdan Adamczyk, Ph.D., in.c.e. Professor of Engineering Director of the Electromagnetic Compatibility Center Grand Valley State University, Michigan, USA Ottawa, Canada July
More informationShenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20
Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC125641 Page: 1 of 20 EMC Test Report Application No. : TB12114299 Applicant : Newmb Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : USB HUB
More informationCTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT
CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CGZ3150428-00472-E-R1 2/F., South Tower, Huoju Building, No.181, Canghai Road,
More informationEN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A
Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result
More informationTest Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013
More informationEMC Test Report. Report Number: M030826
Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report
More informationEMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758
Page 1 of 20 Report No. R011604553E EMC TEST REPORT for DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., LTD. Electronic calculator Model No.: KF15758 Prepared for Address Prepared by Address : DONGGUAN EVER
More informationReport for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027
Report for Excelsys on EMC Measurements for 6Xgen Purchase Order: by email Project Number EMT08J027 Tom O Brien, Engineering Director ElectroMagnetic Technologies Ltd, Cork, June 2007 Executive Summary
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Test of: Maestro Wireless Solutions Limited, Maestro 100evo To: EN 301 489-1 V1.8.1 referencing EN 301 489-7 V1.3.1 Test Report Serial No: RFI-EMC-RP78797JD02A This test report
More informationTEST REPORT on behalf of Shanghai ZLAN Information Technology Co.,Ltd Serial Device Server
TEST REPORT on behalf of Shanghai ZLAN Information Technology Co.,Ltd Serial Device Server Prepared For: Shanghai ZLAN Information Technology Co.,Ltd. Room 1205, Building D Everbright Exhibition Center,
More informationEMC T E S T R E P O R T
Registration No. DAT-P-207/05 EMC T E S T R E P O R T Test Report No. : E33047-00-00NL 04. November 2008 Date of issue Type / Model Name : HCP Best Product Description : Cash register with integrated GPRS
More informationITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA
Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU
More informationBS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE
Page 1 of 18 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel
More informationEMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U
EMC TEST REPORT For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U Prepared for Address : PEAK ELECTRONIC(HUIZHOU)CO., LTD. :
More informationPrepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by
EMC TEST REPORT For KST DIGITAL TECHNOLOGY LIMITED Coreless Servo Model No.: X12-508 Additional Model No.: DS215MG, DS315MG, DS213MG, DS313MG, DS12C, DS12T, X12-306 Prepared for Address : KST DIGITAL TECHNOLOGY
More informationAPPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:
APPLICATION FOR EMC DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co., Ltd led flood light Trade Name: Model: QH-TGC-400W, QH-TGC-300W, QH-TGC-500W, QH-TGC-800W, QH-TGC-1000W Prepared For : Shenzhen
More informationElectromagnetic Compatibility
Electromagnetic Compatibility Introduction to EMC International Standards Measurement Setups Emissions Applications for Switch-Mode Power Supplies Filters 1 What is EMC? A system is electromagnetic compatible
More informationBy order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan
4322705.50 EMC Test report for Plug-in adaptor Models PM1W-IT, PM1WU2-IT, PM1W-GR, PM1W-SP, PM1W-RS, PM1WB-RS, PM1WU2-GR, PM1WU2-SP, PM1WU2-RS, PM1WBU2-RS, PM1W-UK, PM1WU2-UK, PM1W-FR, PM1WU2-FR Guangzhou,
More informationEMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8
EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 Prepared for Address : ShenZhen ZhangQing Electronic LTD :
More informationCE TEST CERTIFICATION
according to Certification No.: E5NC004 European Standard EN 61000-6-4:2001 EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 61000-6-2:2001 ( IEC 61000-4-2:1995/A1:1998, IEC 61000-4-3: 1995/A1:1998,
More informationCE EMC Test Certification
Certification No.: EC57C001 CE EMC Test Certification According to European Standard EN 55022:1998/A1:2000/A2:2003 Class A, EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 55024:1998/A1:2001/A2:2003
More informationEMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS
EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by
More informationTEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed
17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:
More informationEMC test report AU01+E04
Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E04 This test report may not be copied or published in a part without the written authorization of
More informationEMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter
Page 1 of 48 EMC TEST REPORT for Coliy Technology Co.,Ltd. Fluxgate Gaussmeter Prepared for : Coliy Technology Co.,Ltd. Address : Block B,9 th Floor,Xinzhongtai Business Building,Gushu 2nd Road,Xi Town,Bao
More informationr(oilgln TEST REPORT 'AGREB 6 %P\l Br EMC10001 sasa Gros, B.s"{h-$ INSTITUTE EMC and Safetv Laboratorv
r(oilgln Electrlcal Engin.erlng INSTITUTE Br. 21583EMC10001 TEST REPORT EMC and Safetv Laboratorv Page/Pages:1 /40 Test item: CT Powered Time Over-current relay Model: SIGMA XS Manufacturer: KONCAR - ELEKTRIcNI
More informationTABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46
TABLE OF CONTENTS 1. GENERAL INFORMATION...5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...5 1.2 OBJECTIVE...5 1.3 RELATED SUBMITTAL(S)/GRANT(S)...5 1.4 TEST METHODOLOGY...5 1.5 TEST FACILITY...5
More informationEN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd
Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27
15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE
More informationEMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B
Page 1 of 27 Report No. R011412016E-1 EMC TEST REPORT for LEDELS LIGHTING CO., LTD LED module Model No. : LL-F12T4815X6B Prepared for : LEDELS LIGHTING CO., LTD Address : 5F, Block C, Mingjinhai Ind. Park,
More informationELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 1 / 35 TEST REPORT Responsible Party Manufacturer Description of Product Trade Name : Huan Vu Enterprise Co., Ltd. : Huan Vu Enterprise Co.,
More informationTest Report GUANGDONG EAST POWER CO., LTD
Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA906IIRTS, EA906IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014
More informationEMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD
Page 1 of 45 Report No. R011607240E EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD INVERTER CHARGER Model No.: PV35-4K DC24V MPK, PV35-4K DC48V MPK, PV35-5K DC48V MPK, PV35-6K DC48V MPK Prepared
More informationShenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT
Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-89486194-805 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances,
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25
15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Variant Model Name: Applicant: CAMERA HOUSING SAMSUNG TECHWIN CO., LTD. SCX-FH200B SHB-4200 SAMSUNG TECHWIN
More informationTEST REPORT... 1 CONTENT...
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2
More informationCE TEST CERTIFICATION
Certification No.: E5DC001 according to European Standard EN 61000-6-4:2001 EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 61000-6-2:2001 ( IEC 61000-4-2:1995/A1:1998, IEC 61000-4-3: 1995/A1:1998,
More informationReport for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B
Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed
More informationDiscontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz
Reference No.: WTU15U0933879E Page 2 of 45 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationThis annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation
Annex to declaration accreditation (scope accreditation) Locations where activities are performed under accreditation Location Abbreviation/ location code Head Location Vijzelmolenlaan 5 & 7 3447 GX oerden
More information2620 Modular Measurement and Control System
European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic
More informationCE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10
CE/EMC TEST REPORT For HK QNOVATOR TECHNOLOGY CO.,LIMITED Product Name: Vacuum Tube Amplifier Trademark: Model Number: Prepared For: Address: Gemtune GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05,
More informationGuangdong East Power Co., Ltd. Uninterruptible Power Systems
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Uninterruptible Power Systems EAST EA8806, EA8804 Date of Receipt : Nov. 01, 2012 Date of Test: Nov. 03, 2012
More informationBS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C
Page 1 of 23 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel
More informationEMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)
EMC TEST REPORT For Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) Prepared For : Company Limited Liability «Faraday
More informationLS200 TEST DATA IEC61000 SERIES
TEST DATA IEC61000 SERIES DWG. No. PA607-58-01 APPD CHK DWG TDK-Lambda INDEX LS200 PAGE 1. Electrostatic Discharge Immunity Test (IEC61000-4-2) R-1 2. Radiated Radio-Frequency Electromagnetic Field Immunity
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
Location(s) where activities are performed under accreditation Head Office Vijzelmolenlaan 5 & 7 3447 GX oerden The Netherlands Location Abbreviation/ location code Vijzelmolenlaan 5 & 7 3447 GX oerden
More informationTest Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,
Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of, EN 301 489-1 V1.8.1 Electromagnetic compatibility and
More informationTEST REPORT. EN / EN Information technology equipment Radio disturbance / Immunity characteristics Limits and methods of measurement
TEST REPORT EN 55032 / EN 55024 Information technology equipment Radio disturbance / Immunity characteristics Limits and methods of measurement Report Reference No....354297-2TRFEMC Tested by (name, function
More informationEMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.
Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial
More informationEMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.
DONGGUAN FIT-WATCH CO., LTD. EMC REPORT Prepared For : DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province Product Name : Trade Name : Model
More informationTEST REPORT... 1 CONTENT...
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMF RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 5 4 EMI TEST... 6 4.1 DISTURBANCE VOLTAGE ON MAINS TERMINALS ( KHZ- MHZ)...
More information1 SUMMARY OF STANDARDS AND RESULTS
1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: EMISSION Description of Test Item Standard
More informationBulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results
Immunity Testing: radiated immunity 41 Bulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results Immunity Testing: radiated immunity 42 Bulk Current
More information1 Introduction Test Specification Environment Relevant standards Emissions Immunity...
CONTENTS 1 Introduction... 4 2 Test Specification... 6 2.1 Environment... 6 2.2 Relevant standards... 6 2.2.1 Emissions... 6 2.2.2 Immunity... 7 3 Test Results... 8 3.1 Conducted emissions (9kHz to 30MHz)...
More informationReport No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for
Report No.: 9A042401C2 Page 1 of 36 EN 50121-4: 2006 Product: Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client Trade Name: MOXA Model Number: AWK-5222 Prepared for MOXA Inc. Fl.4, No.135, Lane 235,
More informationTest Report According to EN V1.9.2; EN V Starcom GPS Systems Ltd.
DATE: 06 October 2014 I.T.L. (PRODUCT TESTING) LTD. Test Report According to EN 301 489-1 V1.9.2; EN 301 489-7 V1.3.1 for Starcom GPS Systems Ltd. Equipment under test: Container Tracker Triton R Written
More informationEMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.
EMC Testing Report Equipment Under Test: Model Number: Serial No.: Applicant: Address of Applicant: Multi-Frequency (4 Channel Selectable) Twin Photobeam Detector Dual-120CS Dual-90CS, Dual-60CS, Dual-30CS
More informationEMC TEST REPORT. Oina VV AB. Dispenser system. Accurate speedcontrol BLDC/ Report no: Approved by Tobias Gustavsson
EMC TEST REPORT Oina VV AB Dispenser system Accurate speedcontrol BLDC/ Report no: 09007 Prepared by Ulf Heiding Approved by Tobias Gustavsson Date 2009-01-23 This report may not be reproduced other than
More informationAUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN
AUSTRALIA TEST REPORT For KLM Lighting Co., Limited LED Down Light Model No.: KLM-HP30WSN Additional Model No.: KLM-SM-50-002, KLM-HP7WSS, KLM-HP10WSS, KLM-HP12WSS, KLM-HP15WSS, KLM-HP20WSS, KLM-HP30WSS,
More informationTest Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49
Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 The following information was submitted and identified by/on behalf of the client as: Applicant : Ningbo Shanhuang Electric Appliance
More informationPT. SARANA KARYA SOLUSINDO.
Shenzhen BST Technology Co., Ltd. PT. SARANA KARYA SOLUSINDO. EMC REPORT Prepared For : PT. SARANA KARYA SOLUSINDO. Puri Surya Jaya J1. 29 Cluster Vancouver, Gedangan, Sidoarjo, Jawa Timur - Indonesia
More informationFCC PART 15 B MEASUREMENT AND TEST REPORT
FCC PART 15 B MEASUREMENT AND TEST REPORT For FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, 47100 PUCHONG, SELANGOR, MALAYSIA MODEL: Keylock 8800 April 12, 2010 This Report Concerns:
More informationCENTRE OF TESTING SERVICE INTERNATIONAL
CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00097-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China Report
More informationEMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.
EMC TEST REPORT For Shenzhen Smar TEC Technology Company Smart Charger For Li-Ion&Lifepo4 Battery Pack Model No.:SPS-F12S02-021(42.6V/2A) Prepared for : Shenzhen Smar TEC Technology Company Address : 4-5/F.,
More informationEMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China
EMC-Report No.:SZZCT1502030B-EMC-02 EMC Test Report Product Model Number : Drift car : P01 Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China
More informationTest Report GUANGDONG EAST POWER CO., LTD
Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA902IIRTS, EA902IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014
More informationEMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011
EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 All-in-one Digital EMI Analyzer 10 Hz - 3 GHz PMM 9010/30P EMI Analyzer 10 Hz - 3 GHz Our trek started in a small laboratory over 25
More informationRF test report AU01+W02
Customer: Kehlbergstrasse 109 8054 Graz Austria Tel.: +43 664 415 6260 RF test report 170186-AU01+W02 The test result refers exclusively to the tested model. This test report may not be copied or published
More informationTEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.
TEST REPORT Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015 Issued for: Shenzhen Flus Technology Co., Ltd 3rd Floor, Lantian Building,
More informationTest Report. Ningbo Goldmore Industrial Co.,Ltd.
Test Report Applicant: Ningbo Goldmore Industrial Co.,Ltd. Product Name: Brand Name: Model No.: LED CAMPING LANTERN with FAN N/A XJH-8098 Date of Receipt : Sep. 23, 2014 Date of Test: Sep. 25, 2014 Date
More information2004/104/EC Measurement and Test Report
2004/104/EC Measurement and Test Report For LM Technologies Ltd. Unit19, Spectrum House, 32-34, Gordon House Road, London, NW5 1LP, United Kingdom Compliance Directive: Product Description: 2004/104/EC
More informationTABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT
ELECTROMAGNETIC COMPLIANCE TEST REPORT For Electric nail art drill Model Name: HBS-021, HBS-278, HBS-288, HBS-530, HBS-540 Brand Name: Date of Issue: May 7, 2011 Prepared For Houbos Hardware & Electrical
More informationFCC Part 15 Subpart B
Report No.: 15A111603E-F Page 1 of 23 Test Report FCC Part 15 Subpart B for Electromagnetic Interference of Product: Managed PoE Industrial Ethernet Switch Trade Name: N/A Model Number: IS-DG512P-2F-8;
More informationA Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.
A Comparison Between MIL-STD and Commercial EMC Requirements Part 2 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC immunity
More informationEMC VERIFICATION SUMMARY Report No.: SZHH
EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA
More informationTABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11
Page : 2 / 38 TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST 4 3.1 CONDUCTED EMISSION TEST 7 3.2 RADIATED EMISSION TEST 11 3.3 ELECTROSTATIC DISCHARGE IMMUNITY TEST 14
More informationEMC Seminar Series All about EMC Testing and Measurement Seminar 1
EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Introduction to EMC Conducted Immunity Jeffrey Tsang Organized by : Department of Electronic Engineering 1 Basic Immunity Standards: IEC
More informationEMI -- T E S T R E P O R T
Registration No. DAT-P-207/05 EMI -- T E S T R E P O R T - FCC Part 15B - Test Report No. : T32619-00-04HU 24. July 2008 Date of issue Type / Model Name : R-PO7470 Product Description : Handheld Reader
More information