TEST REPORT FROM RFI GLOBAL SERVICES LTD
|
|
- Adele Joleen Hunter
- 5 years ago
- Views:
Transcription
1 FROM RFI GLOBAL SERVICES LTD Test of: Maestro Wireless Solutions Limited, Maestro 100evo To: EN V1.8.1 referencing EN V1.3.1 Test Report Serial No: RFI-EMC-RP78797JD02A This test report is issued under the authority of Scott D Adamo, Operations Manager Global Approvals: Checked By: Andy Graham Signature: Date of Issue: 01 November 2010 This report is issued in portable document format (PDF). It is only a valid copy of the report if it is being viewed in PDF format with the following security options not allowed: Changing the document, Selecting text and graphics, Adding or changing notes and form fields. This report may not be reproduced other than in full, except with the prior written approval of RFI Global Services Ltd. The results in this report apply only to the sample(s) tested.
2 This page has been left intentionally blank. Page 2 of 79 RFI Global Services Ltd.
3 TABLE OF CONTENTS 1. Customer Details Summary of Testing Equipment under Test (EUT) Support Equipment Monitoring Performance Measurement Uncertainty Measurements, Examinations and Derived Results Photographs of EUT Graphical Test Results Test Configuration Drawings RFI Global Services Ltd. Page 3 of 79
4 This page has been intentionally left blank. Page 4 of 79 RFI Global Services Ltd.
5 1. CUSTOMER DETAILS Company Name: Maestro Wireless Solutions Limited Address: Unit , 36/F 118 Connaught Road West Hong Kong RFI Global Services Ltd. Page 5 of 79
6 2. SUMMARY OF TESTING 2.1. Test Specification Reference: EN V1.8.1 ( ) Title: Comments: 2.2. Summary of Test Results Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements The testing to the above standard was carried out in accordance with the specific conditions defined in the standard EN V1.3.1 ( ) Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS) Clause Measurement Type Applicability Result EMISSIONS 8.2 Radiated Emissions (Enclosure) Y Conducted Emissions (DC Power Input / Output Ports) Y 8.4 Conducted Emissions (AC Mains Input / Output Ports) N Harmonic Current Emissions (AC Mains Input Port) N Voltage Fluctuation and Flicker (AC Mains Input Port) N Conducted Emissions (Telecommunication Ports) N 3 - IMMUNITY 9.2 Radio frequency electromagnetic field ( MHz & MHz) Y 9.3 Electrostatic discharge Y 9.4 Fast transients common mode Y 9.5 Radio frequency common mode ( MHz) Y 9.6 Transients and surges, vehicular environment N Voltage dips and interruptions N Surges N 2 - Notes 1. Radiated Emissions measurements were covered in RFI report serial number RFI-EMC-RP78797JD05A V Not applicable. The EUT is DC powered only. 3. Not applicable. There are no telecommunication ports. 4. In accordance with a request from the customer the EUT was exposed to transients and surges that are applied to radio and ancillary equipment intended for vehicular use. KEY: = Complied = Complied, within uncertainty = Did not comply, within uncertainty = Did not comply 2.3. Location of Testing All the measurements described in this report were performed at the premises of RFI Global Services Ltd, Unit 3 Horizon, Wade Road, Kingsland Business Park, Basingstoke, Hampshire RG24 8AH Deviations from the Test Specification For the measurements contained within this test report, there were no deviations from, additions to, or exclusions from the test specification identified above, nor from the requirements defined in the basic standards called up within it. Page 6 of 79 RFI Global Services Ltd.
7 3. EQUIPMENT UNDER TEST (EUT) 3.1. Description of EUT The EUT was a Quad-Band GSM/GPRS modem 3.2. Identification of Equipment under Test (EUT) ID# Description Brand Name Model No Serial No IMEI E1 Modem Maestro Wireless Solutions Limited Maestro 100evo None Stated Port Identification Port Description Type P1 Enclosure - P2 Serial and Audio Connection 15 pin sub-d P3 DC power 4 pin P4 Antenna Connector SMA 3.4. Operating Modes Mode Reference Allocated Idle Radio characteristics Definition The EUT was synchronised with a radio communication tester and allocated a channel in the operating bands; GSM 900 and DCS The EUT was synchronised with a radio communication tester but not allocated a channel in the operating bands; GSM 900 and DCS GSM Bands tested: Rated Output Power (dbm) Transmit Frequency range (MHz) ARFCN Transmit Frequency (MHz) Receive Frequency range (MHz) ARFCN Receive Frequency (MHz) GSM DCS Supported Technologies e.g. Circuit Switched Voice/Data, Packet Switched Data GPRS/ EDGE Circuit Switched Voice/Data, Packet Switched Data GPRS 3.5. Configuration and Peripherals Description: 3.6. Modifications NOTE: No modifications were made to the EUT during the course of testing 3.7. Additional Information Related to Testing Equipment Category: Please refer to the Test Configuration and Photograph section for schematic drawing(s) and/or photograph(s) of the test configuration(s) employed in the course of testing. GSM/GPRS Intended Operating Environment: Cycle Time: Power Supply Requirement(s): Weight: Dimensions: Antenna Type Residential/Commercial/Light Industry < 1 s 6 VDC to 32 VDC 100 g 23 x 90 x 72 mm Removable RFI Global Services Ltd. Page 7 of 79
8 4. SUPPORT EQUIPMENT 4.1. Identification of Support Equipment Description Manufacturer Model No Serial No Notebook PC Dell Inc D610 CN-0C Radio Communication Tester Rohde & Schwarz CMU Interconnecting Cables NOTE: No interconnecting cables were used during the course of testing. Page 8 of 79 RFI Global Services Ltd.
9 5. MONITORING PERFORMANCE 5.1. Overview Performance criteria were used to make a decision on whether the EUT passed or failed the applicable immunity tests. The following categories of performance criteria were defined for the measurements included within this test report Continuous phenomena (CT/CR) Criteria During test After test CT A communication link shall be established and maintained The BLER shall not exceed 0.01 during the test sequence No unintentional responses (Idle mode) Operate as intended the communication link shall be maintained No loss of function No loss of stored data CR A communication link shall be established and maintained. The BLER shall not exceed 0.01 during the test sequence Operate as intended the communication link shall be maintained No loss of function No loss of stored data 5.3. Transient phenomena (TT/TR) Criteria During test After test TT A communication link shall be established and maintained. At the conclusion of each exposure, the EUT shall operate with no user noticeable loss of the communication link No unintentional responses (Idle mode) Operate as intended the communication link shall be maintained No loss of function No loss of stored data TR A communication link shall be established and maintained. At the conclusion of each exposure, the EUT shall operate with no user noticeable loss of the communication link Operate as intended the communication link shall be maintained No loss of function No loss of stored data 5.4. Monitoring EUT Performance during Testing For the purposes of testing, the term operate as intended was defined as: For the purposes of testing, an unintentional response was defined as: Method used to determine whether user control functions and stored data were lost after the EMC exposure: Method used to verify that a communications link was established and maintained (if appropriate): Method of assessment of level of performance or degradation of performance during and/or after EMC exposure: The EUT remained in a communication link with the radio communication tester. The communication link between the EUT and the radio communication tester was lost. A functionality check was performed after each exposure. The status of the communication link was monitored via the radio communication tester. A radio communication tester was used to monitor the BLER which was not to exceed 0.01 RFI Global Services Ltd. Page 9 of 79
10 6. MEASUREMENT UNCERTAINTY 6.1. Overview No measurement or test can ever be perfect and the imperfections give rise to error of measurement in the results. Consequently, the result of a measurement is only an approximation to the value of the measurand (the specific quantity subject to measurement) and is only complete when accompanied by a statement regarding the uncertainty of approximation. The measurement uncertainty may need to be taken into account when interpreting the test results included within this test report Method of calculation The methods used to calculate the uncertainties included within this test report are in line with those recommended within the various measurement specifications. Where measurement specifications do not include guidelines for the evaluation of measurement uncertainty, the published guidance of the United Kingdom Accreditation Service (UKAS) is followed. Page 10 of 79 RFI Global Services Ltd.
11 7. MEASUREMENTS, EXAMINATIONS AND DERIVED RESULTS 7.1. General Comments This section contains the test result sheets for the measurements listed in Section 2.2. Summary of Test Results (above) The measurement uncertainties stated in the test result sheets were calculated in accordance with documented best practice and represent a confidence level of 95%. Where only confidence level is given, it has been demonstrated that the relevant items of test equipment used meet the specified requirements in the standard with at least this level of confidence Please refer to Section 6. Measurement Uncertainty on page 10 for details of our treatment of measurement uncertainty. RFI Global Services Ltd. Page 11 of 79
12 CONDUCTED EMISSIONS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 25 C to 25 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 22 % to 22 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1009 mb to 1009 mb UNCERTAINTY (±): ±3.99 db EQUIPMENT CLASS: Class B CATEGORY: Not applicable MEASUREMENT METHOD: LISN (Vehicle) TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 55022: 2006 inc. Amendment 1: 2007 TITLE: Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: FUNCTION(S) MONITORED: GSM 900 Allocated (12 VDC) Not Applicable MEASUREMENT RESULTS No. Frequency (MHz) Line Detector Level (dbμv) Limit (dbμv) Margin (db) Graph No. Result Live 1 Quasi-Peak GPH\78797JD02\001 Complied Live 1 Quasi-Peak GPH\78797JD02\001 Complied Neutral Quasi-Peak GPH\78797JD02\001 Complied Live 1 Quasi-Peak GPH\78797JD02\001 Complied Neutral Quasi-Peak GPH\78797JD02\001 Complied Live 1 Quasi-Peak GPH\78797JD02\001 Complied Live 1 Average (CISPR) GPH\78797JD02\001 Complied Live 1 Average (CISPR) GPH\78797JD02\001 Complied Neutral Average (CISPR) GPH\78797JD02\001 Complied Live 1 Average (CISPR) GPH\78797JD02\001 Complied Live 1 Average (CISPR) GPH\78797JD02\001 Complied Live 1 Average (CISPR) GPH\78797JD02\001 Complied NOTES N/A During measurement the engineer did not record any specific notes relevant to report. Page 12 of 79 RFI Global Services Ltd.
13 TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required C mm cable RG Feb L1005 Radio Communication Tester CMU Jan A051 ESH3-Z6 V Network ESH3-Z6 18 Mar A052 ESH3-Z6 V-Network ESH3-Z6 18 Mar A1304 DC to 18 GHz Power 5 W 370 BNM Calibration not required A1305 DC to 18 GHz Power 5 W 370 BNM Calibrated before use A1830 N-Type Pulse Limiter ESH3-Z2 01 Mar A1767 Thermo Hygrometer Mar M1273 EMI Test Receiver ESIB Apr RFI Global Services Ltd. Page 13 of 79
14 CONDUCTED EMISSIONS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 25 C to 25 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 22 % to 22 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1009 mb to 1009 mb UNCERTAINTY (±): ±3.99 db EQUIPMENT CLASS: Class B CATEGORY: Not applicable MEASUREMENT METHOD: LISN (Vehicle) TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 55022: 2006 inc. Amendment 1: 2007 TITLE: Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: FUNCTION(S) MONITORED: GSM 900 Idle (12 VDC) Not Applicable MEASUREMENT RESULTS No. Frequency (MHz) Line Detector Level (dbμv) Limit (dbμv) Margin (db) Graph No. Result Live 1 Quasi-Peak GPH\78797JD02\002 Complied Neutral Quasi-Peak GPH\78797JD02\002 Complied Neutral Quasi-Peak GPH\78797JD02\002 Complied Neutral Quasi-Peak GPH\78797JD02\002 Complied Neutral Quasi-Peak GPH\78797JD02\002 Complied Live 1 Quasi-Peak GPH\78797JD02\002 Complied Live 1 Average (CISPR) GPH\78797JD02\002 Complied Live 1 Average (CISPR) GPH\78797JD02\002 Complied Neutral Average (CISPR) GPH\78797JD02\002 Complied Neutral Average (CISPR) GPH\78797JD02\002 Complied Neutral Average (CISPR) GPH\78797JD02\002 Complied Live 1 Average (CISPR) GPH\78797JD02\002 Complied Page 14 of 79 RFI Global Services Ltd.
15 NOTES N/A During measurement the engineer did not record any specific notes relevant to report. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required C mm cable RG Feb L1005 Radio Communication Tester CMU Jan A051 ESH3-Z6 V Network ESH3-Z6 18 Mar A052 ESH3-Z6 V-Network ESH3-Z6 18 Mar A1304 DC to 18 GHz Power 5 W 370 BNM Calibration not required A1305 DC to 18 GHz Power 5 W 370 BNM Calibrated before use A1830 N-Type Pulse Limiter ESH3-Z2 01 Mar A1767 Thermo Hygrometer Mar M1273 EMI Test Receiver ESIB Apr RFI Global Services Ltd. Page 15 of 79
16 CONDUCTED EMISSIONS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 25 C to 25 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 22 % to 22 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1009 mb to 1009 mb UNCERTAINTY (±): ±3.99 db EQUIPMENT CLASS: Class B CATEGORY: Not applicable MEASUREMENT METHOD: LISN (Vehicle) TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 55022: 2006 inc. Amendment 1: 2007 TITLE: Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: FUNCTION(S) MONITORED: DCS 1800 Allocated (12 VDC) Not Applicable MEASUREMENT RESULTS No. Frequency (MHz) Line Detector Level (dbμv) Limit (dbμv) Margin (db) Graph No. Result Live 1 Quasi-Peak GPH\78797JD02\003 Complied Live 1 Quasi-Peak GPH\78797JD02\003 Complied Neutral Quasi-Peak GPH\78797JD02\003 Complied Live 1 Quasi-Peak GPH\78797JD02\003 Complied Neutral Quasi-Peak GPH\78797JD02\003 Complied Live 1 Quasi-Peak GPH\78797JD02\003 Complied Live 1 Average (CISPR) GPH\78797JD02\003 Complied Live 1 Average (CISPR) GPH\78797JD02\003 Complied Live 1 Average (CISPR) GPH\78797JD02\003 Complied Neutral Average (CISPR) GPH\78797JD02\003 Complied Neutral Average (CISPR) GPH\78797JD02\003 Complied Live 1 Average (CISPR) GPH\78797JD02\003 Complied Page 16 of 79 RFI Global Services Ltd.
17 NOTES N/A During measurement the engineer did not record any specific notes relevant to report. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required C mm cable RG Feb L1005 Radio Communication Tester CMU Jan A051 ESH3-Z6 V Network ESH3-Z6 18 Mar A052 ESH3-Z6 V-Network ESH3-Z6 18 Mar A1304 DC to 18 GHz Power 5 W 370 BNM Calibration not required A1305 DC to 18 GHz Power 5 W 370 BNM Calibrated before use A1830 N-Type Pulse Limiter ESH3-Z2 01 Mar A1767 Thermo Hygrometer Mar M1273 EMI Test Receiver ESIB Apr RFI Global Services Ltd. Page 17 of 79
18 CONDUCTED EMISSIONS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 25 C to 25 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 22 % to 22 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1009 mb to 1009 mb UNCERTAINTY (±): ±3.99 db EQUIPMENT CLASS: Class B CATEGORY: Not applicable MEASUREMENT METHOD: LISN (Vehicle) TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 55022: 2006 inc. Amendment 1: 2007 TITLE: Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: FUNCTION(S) MONITORED: DCS 1800 Idle (12 VDC) Not Applicable MEASUREMENT RESULTS No. Frequency (MHz) Line Detector Level (dbμv) Limit (dbμv) Margin (db) Graph No. Result Neutral Quasi-Peak GPH\78797JD02\004 Complied Neutral Quasi-Peak GPH\78797JD02\004 Complied Live 1 Quasi-Peak GPH\78797JD02\004 Complied Live 1 Quasi-Peak GPH\78797JD02\004 Complied Neutral Quasi-Peak GPH\78797JD02\004 Complied Live 1 Quasi-Peak GPH\78797JD02\004 Complied Live 1 Average (CISPR) GPH\78797JD02\004 Complied Neutral Average (CISPR) GPH\78797JD02\004 Complied Neutral Average (CISPR) GPH\78797JD02\004 Complied Neutral Average (CISPR) GPH\78797JD02\004 Complied Neutral Average (CISPR) GPH\78797JD02\004 Complied Neutral Average (CISPR) GPH\78797JD02\004 Complied Page 18 of 79 RFI Global Services Ltd.
19 NOTES N/A During measurement the engineer did not record any specific notes relevant to report. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required C mm cable RG Feb L1005 Radio Communication Tester CMU Jan A051 ESH3-Z6 V Network ESH3-Z6 18 Mar A052 ESH3-Z6 V-Network ESH3-Z6 18 Mar A1304 DC to 18 GHz Power 5 W 370 BNM Calibration not required A1305 DC to 18 GHz Power 5 W 370 BNM Calibrated before use A1830 N-Type Pulse Limiter ESH3-Z2 01 Mar A1767 Thermo Hygrometer Mar M1273 EMI Test Receiver ESIB Apr RFI Global Services Ltd. Page 19 of 79
20 CONDUCTED EMISSIONS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 25 C to 25 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 22 % to 22 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1009 mb to 1009 mb UNCERTAINTY (±): ±3.99 db EQUIPMENT CLASS: Class B CATEGORY: Not applicable MEASUREMENT METHOD: LISN (Vehicle) TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 55022: 2006 inc. Amendment 1: 2007 TITLE: Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: FUNCTION(S) MONITORED: DCS 1800 Idle (24 VDC) Not Applicable MEASUREMENT RESULTS No. Frequency (MHz) Line Detector Level (dbμv) Limit (dbμv) Margin (db) Graph No. Result Neutral Quasi-Peak GPH\78797JD02\005 Complied Live 1 Quasi-Peak GPH\78797JD02\005 Complied Neutral Quasi-Peak GPH\78797JD02\005 Complied Live 1 Quasi-Peak GPH\78797JD02\005 Complied Neutral Quasi-Peak GPH\78797JD02\005 Complied Live 1 Quasi-Peak GPH\78797JD02\005 Complied Live 1 Average (CISPR) GPH\78797JD02\005 Complied Live 1 Average (CISPR) GPH\78797JD02\005 Complied Live 1 Average (CISPR) GPH\78797JD02\005 Complied Live 1 Average (CISPR) GPH\78797JD02\005 Complied Neutral Average (CISPR) GPH\78797JD02\005 Complied Neutral Average (CISPR) GPH\78797JD02\005 Complied Page 20 of 79 RFI Global Services Ltd.
21 NOTES N/A During measurement the engineer did not record any specific notes relevant to report. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required C mm cable RG Feb L1005 Radio Communication Tester CMU Jan A051 ESH3-Z6 V Network ESH3-Z6 18 Mar A052 ESH3-Z6 V-Network ESH3-Z6 18 Mar A1304 DC to 18 GHz Power 5 W 370 BNM Calibration not required A1305 DC to 18 GHz Power 5 W 370 BNM Calibrated before use A1830 N-Type Pulse Limiter ESH3-Z2 01 Mar A1767 Thermo Hygrometer Mar M1273 EMI Test Receiver ESIB Apr RFI Global Services Ltd. Page 21 of 79
22 CONDUCTED EMISSIONS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 25 C to 25 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 22 % to 22 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1009 mb to 1009 mb UNCERTAINTY (±): ±3.99 db EQUIPMENT CLASS: Class B CATEGORY: Not applicable MEASUREMENT METHOD: LISN (Vehicle) TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 55022: 2006 inc. Amendment 1: 2007 TITLE: Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: FUNCTION(S) MONITORED: DCS 1800 Allocated (24 VDC) Not Applicable MEASUREMENT RESULTS No. Frequency (MHz) Line Detector Level (dbμv) Limit (dbμv) Margin (db) Graph No. Result Live 1 Quasi-Peak GPH\78797JD02\006 Complied Live 1 Quasi-Peak GPH\78797JD02\006 Complied Live 1 Quasi-Peak GPH\78797JD02\006 Complied Live 1 Quasi-Peak GPH\78797JD02\006 Complied Neutral Quasi-Peak GPH\78797JD02\006 Complied Live 1 Quasi-Peak GPH\78797JD02\006 Complied Live 1 Average (CISPR) GPH\78797JD02\006 Complied Live 1 Average (CISPR) GPH\78797JD02\006 Complied Neutral Average (CISPR) GPH\78797JD02\006 Complied Neutral Average (CISPR) GPH\78797JD02\006 Complied Neutral Average (CISPR) GPH\78797JD02\006 Complied Live 1 Average (CISPR) GPH\78797JD02\006 Complied Page 22 of 79 RFI Global Services Ltd.
23 NOTES N/A During measurement the engineer did not record any specific notes relevant to report. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required C mm cable RG Feb L1005 Radio Communication Tester CMU Jan A051 ESH3-Z6 V Network ESH3-Z6 18 Mar A052 ESH3-Z6 V-Network ESH3-Z6 18 Mar A1304 DC to 18 GHz Power 5 W 370 BNM Calibration not required A1305 DC to 18 GHz Power 5 W 370 BNM Calibrated before use A1830 N-Type Pulse Limiter ESH3-Z2 01 Mar A1767 Thermo Hygrometer Mar M1273 EMI Test Receiver ESIB Apr RFI Global Services Ltd. Page 23 of 79
24 CONDUCTED EMISSIONS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 25 C to 25 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 22 % to 22 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1009 mb to 1009 mb UNCERTAINTY (±): ±3.99 db EQUIPMENT CLASS: Class B CATEGORY: Not applicable MEASUREMENT METHOD: LISN (Vehicle) TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 55022: 2006 inc. Amendment 1: 2007 TITLE: Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: FUNCTION(S) MONITORED: GSM 900 Allocated (24 VDC) Not Applicable MEASUREMENT RESULTS No. Frequency (MHz) Line Detector Level (dbμv) Limit (dbμv) Margin (db) Graph No. Result Live 1 Quasi-Peak GPH\78797JD02\007 Complied Live 1 Quasi-Peak GPH\78797JD02\007 Complied Live 1 Quasi-Peak GPH\78797JD02\007 Complied Live 1 Quasi-Peak GPH\78797JD02\007 Complied Neutral Quasi-Peak GPH\78797JD02\007 Complied Live 1 Quasi-Peak GPH\78797JD02\007 Complied Live 1 Average (CISPR) GPH\78797JD02\007 Complied Neutral Average (CISPR) GPH\78797JD02\007 Complied Live 1 Average (CISPR) GPH\78797JD02\007 Complied Live 1 Average (CISPR) GPH\78797JD02\007 Complied Live 1 Average (CISPR) GPH\78797JD02\007 Complied Live 1 Average (CISPR) GPH\78797JD02\007 Complied Page 24 of 79 RFI Global Services Ltd.
25 NOTES N/A During measurement the engineer did not record any specific notes relevant to report. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required C mm cable RG Feb L1005 Radio Communication Tester CMU Jan A051 ESH3-Z6 V Network ESH3-Z6 18 Mar A052 ESH3-Z6 V-Network ESH3-Z6 18 Mar A1304 DC to 18 GHz Power 5 W 370 BNM Calibration not required A1305 DC to 18 GHz Power 5 W 370 BNM Calibrated before use A1830 N-Type Pulse Limiter ESH3-Z2 01 Mar A1767 Thermo Hygrometer Mar M1273 EMI Test Receiver ESIB Apr RFI Global Services Ltd. Page 25 of 79
26 CONDUCTED EMISSIONS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 25 C to 25 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 22 % to 22 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1009 mb to 1009 mb UNCERTAINTY (±): ±3.99 db EQUIPMENT CLASS: Class B CATEGORY: Not applicable MEASUREMENT METHOD: LISN (Vehicle) TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN 55022: 2006 inc. Amendment 1: 2007 TITLE: Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: FUNCTION(S) MONITORED: GSM 900 Idle (24 VDC) Not Applicable MEASUREMENT RESULTS No. Frequency (MHz) Line Detector Level (dbμv) Limit (dbμv) Margin (db) Graph No. Result Live 1 Quasi-Peak GPH\78797JD02\008 Complied Neutral Quasi-Peak GPH\78797JD02\008 Complied Neutral Quasi-Peak GPH\78797JD02\008 Complied Live 1 Quasi-Peak GPH\78797JD02\008 Complied Neutral Quasi-Peak GPH\78797JD02\008 Complied Live 1 Quasi-Peak GPH\78797JD02\008 Complied Neutral Average (CISPR) GPH\78797JD02\008 Complied Live 1 Average (CISPR) GPH\78797JD02\008 Complied Neutral Average (CISPR) GPH\78797JD02\008 Complied Neutral Average (CISPR) GPH\78797JD02\008 Complied Neutral Average (CISPR) GPH\78797JD02\008 Complied Neutral Average (CISPR) GPH\78797JD02\008 Complied Page 26 of 79 RFI Global Services Ltd.
27 NOTES N/A During measurement the engineer did not record any specific notes relevant to report. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required C mm cable RG Feb L1005 Radio Communication Tester CMU Jan A051 ESH3-Z6 V Network ESH3-Z6 18 Mar A052 ESH3-Z6 V-Network ESH3-Z6 18 Mar A1304 DC to 18 GHz Power 5 W 370 BNM Calibration not required A1305 DC to 18 GHz Power 5 W 370 BNM Calibrated before use A1830 N-Type Pulse Limiter ESH3-Z2 01 Mar A1767 Thermo Hygrometer Mar M1273 EMI Test Receiver ESIB Apr RFI Global Services Ltd. Page 27 of 79
28 RADIATED IMMUNITY - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 27 C to 27 C TEST ENGINEER: Jack Suter RELATIVE HUMIDITY: 35 % to 35 % DATE OF TEST: 13 Oct 2010 ATMOSPHERIC PRESSURE: 1001 mb to 1001 mb UNCERTAINTY (±): ±2.56 db DWELL TIME (seconds): 1.5 s PERFORMANCE CRITERIA: Criteria CR/CT FREQUENCY RANGE: 80 MHz to 2.7 GHz LEVEL: 3 V/m SWEEP RATE: x 10-3 decades/s STEP SIZE: 1% log of momentary frequency MODULATION: 80% 1 khz TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN :2006 TITLE: Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test COMMENTS The list of actual test frequencies used during these measurements is available on request. DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: GSM 900 Allocated FUNCTION(S) MONITORED: A radio communication tester was used to monitor the BLER which was not to exceed 0.01 MEASUREMENT RESULTS No. Frequency Band (MHz) Spot Frequency (MHz) Face Antenna Polarity Level (V/m) Notes Result 1 80 MHz to 1000 MHz - Front Horizontal 3 V/m - Complied MHz to 2700 MHz - Front Horizontal 3 V/m - Complied 3 80 MHz to 1000 MHz - Left Horizontal 3 V/m - Complied MHz to 2700 MHz - Left Horizontal 3 V/m - Complied 5 80 MHz to 1000 MHz - Rear Horizontal 3 V/m - Complied MHz to 2700 MHz - Rear Horizontal 3 V/m - Complied 7 80 MHz to 1000 MHz - Right Horizontal 3 V/m - Complied MHz to 2700 MHz - Right Horizontal 3 V/m - Complied 9 80 MHz to 1000 MHz - Front Vertical 3 V/m - Complied MHz to 2700 MHz - Front Vertical 3 V/m - Complied Page 28 of 79 RFI Global Services Ltd.
29 MEASUREMENT RESULTS No. Frequency Band (MHz) Spot Frequency (MHz) Face Antenna Polarity Level (V/m) Notes Result MHz to 1000 MHz - Left Vertical 3 V/m - Complied MHz to 2700 MHz - Left Vertical 3 V/m - Complied MHz to 1000 MHz - Rear Vertical 3 V/m - Complied MHz to 2700 MHz - Rear Vertical 3 V/m - Complied MHz to 1000 MHz - Right Vertical 3 V/m - Complied MHz to 2700 MHz - Right Vertical 3 V/m - Complied NOTE(S) N/A During measurement the engineer did not record any specific notes relevant to report. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL L1005 Radio Communication Tester CMU Jan C322 Cable UFA 210A x50 17 Feb G013 SMHU Signal Generator SMHU 13 May M1170 Power Meter 10 khz to 2 GHz CPW 9670 Calibrated as part of system A1525 ETS 3149 Immunity Antenna 3149 Calibrated as part of system A1309 Bi-Directional Coaxial Coupler 3020A Calibrated as part of system C m SMA Cable FA210B-1-010M-30X30 Calibrated before use M1241 Power Meter NRVD Calibrated as part of system C1222 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C1224 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C m Cable None Stated 17 Feb C m Cable None Stated 17 Feb C1223 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Rosenberger Cable FA210A Feb C303 Cable UFA 210A x50 17 Feb C300 Cable UFA 210A x50 17 Feb C1224 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C m Rosenberger Cable None Stated 17 Feb C1225 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C1122 Cable FA210A Feb M1140 Radio Communications Analyser MT8820A Calibration not required RFI Global Services Ltd. Page 29 of 79
30 RADIATED IMMUNITY - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 25 C to 25 C TEST ENGINEER: Nicholas Jones RELATIVE HUMIDITY: 32 % to 32 % DATE OF TEST: 18 Oct 2010 ATMOSPHERIC PRESSURE: 1003 mb to 1003 mb UNCERTAINTY (±): ±2.56 db DWELL TIME (seconds): 1.5 s PERFORMANCE CRITERIA: Criteria CR/CT FREQUENCY RANGE: 80 MHz to 2.7 GHz LEVEL: 3 V/m SWEEP RATE: x 10-3 decades/s STEP SIZE: 1% log of momentary frequency MODULATION: 80% 1 khz TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN :2006 TITLE: Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test COMMENTS The list of actual test frequencies used during these measurements is available on request. DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: FUNCTION(S) MONITORED: GSM 900 Idle A spectrum analyser was used to monitor for unintentional transmissions from the EUT MEASUREMENT RESULTS No. Frequency Band (MHz) Spot Frequency (MHz) Face Antenna Polarity Level (V/m) Notes Result 1 80 MHz to 1000 MHz - Front Horizontal 3 V/m - Complied MHz to 2700 MHz - Front Horizontal 3 V/m - Complied 3 80 MHz to 1000 MHz - Left Horizontal 3 V/m - Complied MHz to 2700 MHz - Left Horizontal 3 V/m - Complied 5 80 MHz to 1000 MHz - Rear Horizontal 3 V/m - Complied MHz to 2700 MHz - Rear Horizontal 3 V/m - Complied 7 80 MHz to 1000 MHz - Right Horizontal 3 V/m - Complied MHz to 2700 MHz - Right Horizontal 3 V/m - Complied 9 80 MHz to 1000 MHz - Front Vertical 3 V/m - Complied MHz to 2700 MHz - Front Vertical 3 V/m - Complied Page 30 of 79 RFI Global Services Ltd.
31 MEASUREMENT RESULTS No. Frequency Band (MHz) Spot Frequency (MHz) Face Antenna Polarity Level (V/m) Notes Result MHz to 1000 MHz - Left Vertical 3 V/m - Complied MHz to 2700 MHz - Left Vertical 3 V/m - Complied MHz to 1000 MHz - Rear Vertical 3 V/m - Complied MHz to 2700 MHz - Rear Vertical 3 V/m - Complied MHz to 1000 MHz - Right Vertical 3 V/m - Complied MHz to 2700 MHz - Right Vertical 3 V/m - Complied NOTE(S) N/A During measurement the engineer did not record any specific notes relevant to report. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL L1005 Radio Communication Tester CMU Jan C322 Cable UFA 210A x50 17 Feb G013 SMHU Signal Generator SMHU 13 May M1170 Power Meter 10 khz to 2 GHz CPW 9670 Calibrated as part of system A1525 ETS 3149 Immunity Antenna 3149 Calibrated as part of system A1309 Bi-Directional Coaxial Coupler 3020A Calibrated as part of system C m SMA Cable FA210B-1-010M-30X30 Calibrated before use M1241 Power Meter NRVD Calibrated as part of system C1222 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C1224 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C m Cable None Stated 17 Feb C m Cable None Stated 17 Feb C1223 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Rosenberger Cable FA210A Feb C303 Cable UFA 210A x50 17 Feb C300 Cable UFA 210A x50 17 Feb C1224 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C m Rosenberger Cable None Stated 17 Feb C1225 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C1122 Cable FA210A Feb RFI Global Services Ltd. Page 31 of 79
32 RADIATED IMMUNITY - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 25 C to 24 C TEST ENGINEER: Jack Suter RELATIVE HUMIDITY: 29 % to 30 % DATE OF TEST: 13 Oct 2010 ATMOSPHERIC PRESSURE: 1011 mb to 1011 mb UNCERTAINTY (±): ±2.56 db DWELL TIME (seconds): 1.5 s PERFORMANCE CRITERIA: Criteria CR/CT FREQUENCY RANGE: 80 MHz to 2.7 GHz LEVEL: 3 V/m SWEEP RATE: x 10-3 decades/s STEP SIZE: 1% log of momentary frequency MODULATION: 80% 1 khz TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN :2006 TITLE: Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test COMMENTS The list of actual test frequencies used during these measurements is available on request. DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: DCS 1800 Allocated FUNCTION(S) MONITORED: A radio communication tester was used to monitor the BLER which was not to exceed 0.01 MEASUREMENT RESULTS No. Frequency Band (MHz) Spot Frequency (MHz) Face Antenna Polarity Level (V/m) Notes Result 1 80 MHz to 1000 MHz - Front Horizontal 3 V/m - Complied MHz to 2700 MHz - Front Horizontal 3 V/m - Complied 3 80 MHz to 1000 MHz - Left Horizontal 3 V/m - Complied MHz to 2700 MHz - Left Horizontal 3 V/m - Complied 5 80 MHz to 1000 MHz - Rear Horizontal 3 V/m - Complied MHz to 2700 MHz - Rear Horizontal 3 V/m - Complied 7 80 MHz to 1000 MHz - Right Horizontal 3 V/m - Complied MHz to 2700 MHz - Right Horizontal 3 V/m - Complied 9 80 MHz to 1000 MHz - Front Vertical 3 V/m - Complied MHz to 2700 MHz - Front Vertical 3 V/m - Complied Page 32 of 79 RFI Global Services Ltd.
33 MEASUREMENT RESULTS No. Frequency Band (MHz) Spot Frequency (MHz) Face Antenna Polarity Level (V/m) Notes Result MHz to 1000 MHz - Left Vertical 3 V/m - Complied MHz to 2700 MHz - Left Vertical 3 V/m - Complied MHz to 1000 MHz - Rear Vertical 3 V/m - Complied MHz to 2700 MHz - Rear Vertical 3 V/m - Complied MHz to 1000 MHz - Right Vertical 3 V/m - Complied MHz to 2700 MHz - Right Vertical 3 V/m - Complied NOTE(S) N/A During measurement the engineer did not record any specific notes relevant to report. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL L1005 Radio Communication Tester CMU Jan C322 Cable UFA 210A x50 17 Feb G013 SMHU Signal Generator SMHU 13 May M1170 Power Meter 10 khz to 2 GHz CPW 9670 Calibrated as part of system A1525 ETS 3149 Immunity Antenna 3149 Calibrated as part of system A to 1000 MHz Bi-Directional Coaxial Coupler 3020A Calibrated as part of system C m SMA Cable FA210B-1-010M-30X30 Calibrated before use M1241 Power Meter NRVD Calibrated as part of system C1222 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C1224 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C m Cable None Stated 17 Feb C m Cable None Stated 17 Feb C1223 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Rosenberger Cable FA210A Feb C303 Cable UFA 210A x50 17 Feb C300 Cable UFA 210A x50 17 Feb C1224 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C m Rosenberger Cable None Stated 17 Feb C1225 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C1122 Cable FA210A Feb RFI Global Services Ltd. Page 33 of 79
34 RADIATED IMMUNITY - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 10 EUT: Maestro 100evo TEMPERATURE: 21 C to 21 C TEST ENGINEER: Nicholas Jones RELATIVE HUMIDITY: 37 % to 37 % DATE OF TEST: 19 Oct 2010 ATMOSPHERIC PRESSURE: 999 mb to 999 mb UNCERTAINTY (±): ±2.56 db DWELL TIME (seconds): 1.5 s PERFORMANCE CRITERIA: Criteria CR/CT FREQUENCY RANGE: 80 MHz to 2.7 GHz LEVEL: 3 V/m SWEEP RATE: x 10-3 decades/s STEP SIZE: 1% log of momentary frequency MODULATION: 80% 1 khz TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN :2006 inc. Amendment 1:2008 TITLE: Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test COMMENTS The list of actual test frequencies used during these measurements is available on request. DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: FUNCTION(S) MONITORED: DCS 1800 Idle A spectrum analyser was used to monitor for unintentional transmissions from the EUT MEASUREMENT RESULTS No. Frequency Band (MHz) Spot Frequency (MHz) Face Antenna Polarity Level (V/m) Notes Result 1 80 MHz to 1000 MHz - Front Horizontal 3 V/m - Complied MHz to 2700 MHz - Front Horizontal 3 V/m - Complied 3 80 MHz to 1000 MHz - Left Horizontal 3 V/m - Complied MHz to 2700 MHz - Left Horizontal 3 V/m - Complied 5 80 MHz to 1000 MHz - Rear Horizontal 3 V/m - Complied MHz to 2700 MHz - Rear Horizontal 3 V/m - Complied 7 80 MHz to 1000 MHz - Right Horizontal 3 V/m - Complied MHz to 2700 MHz - Right Horizontal 3 V/m - Complied 9 80 MHz to 1000 MHz - Front Vertical 3 V/m - Complied MHz to 2700 MHz - Front Vertical 3 V/m - Complied Page 34 of 79 RFI Global Services Ltd.
35 MEASUREMENT RESULTS No. Frequency Band (MHz) Spot Frequency (MHz) Face Antenna Polarity Level (V/m) Notes Result MHz to 1000 MHz - Left Vertical 3 V/m - Complied MHz to 2700 MHz - Left Vertical 3 V/m - Complied MHz to 1000 MHz - Rear Vertical 3 V/m - Complied MHz to 2700 MHz - Rear Vertical 3 V/m - Complied MHz to 1000 MHz - Right Vertical 3 V/m - Complied MHz to 2700 MHz - Right Vertical 3 V/m - Complied NOTE(S) N/A During measurement the engineer did not record any specific notes relevant to report. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL L1005 Radio Communication Tester CMU Jan C322 Cable UFA 210A x50 17 Feb G013 SMHU Signal Generator SMHU 13 May M1170 Power Meter 10 khz to 2 GHz CPW 9670 Calibrated as part of system A1525 ETS 3149 Immunity Antenna 3149 Calibrated as part of system A to 1000 MHz Bi-Directional Coaxial Coupler 3020A Calibrated as part of system C m SMA Cable FA210B-1-010M-30X30 Calibrated before use M1241 Power Meter NRVD Calibrated as part of system C1222 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C1224 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C m Cable None Stated 17 Feb C m Cable None Stated 17 Feb C1223 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Rosenberger Cable FA210A Feb C303 Cable UFA 210A x50 17 Feb C300 Cable UFA 210A x50 17 Feb C1224 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C m Rosenberger Cable None Stated 17 Feb C1225 RG21370 MIL-C-170 RG21370 MIL-C-170 Calibrated as part of system C m Cable None Stated 17 Feb C1122 Cable FA210A Feb RFI Global Services Ltd. Page 35 of 79
36 ELECTROSTATIC DISCHARGE - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 6 EUT: Maestro 100evo TEMPERATURE: 21 C to 21 C TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 39 % to 39 % DATE OF TEST: 16 Oct 2010 ATMOSPHERIC PRESSURE: 1006 mb to 1006 mb UNCERTAINTY (±): 95% confidence level AIR CONTACT LIMIT: 8 kv PERFORMANCE CRITERIA: Criterion TR/TT DIRECT CONTACT LIMIT: 4 kv TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 1995 including Amendment A1: 1998 and Amendment A2: 2001 TITLE: Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: GSM 900 Allocated FUNCTION(S) MONITORED: A radio communication tester was used to monitor the BLER which was not to exceed 0.01 DIRECT CONTACT TO EUT Test Points No. Attempted Test Voltage (kv) Notes Result 1 to 8 10 ± Complied 1 to 8 10 ± Complied AIR GAP TO EUT Test Points No. Attempted Test Voltage (kv) Notes Result A to D 10 ± Complied A to D 10 ± Complied A to D 10 ± Complied POSITION TO OBJECT IN VICINITY OF EUT (HORIZONTAL COUPLING PLANE) Test Points No. Attempted Test Voltage (kv) Notes Result Front, Left, Rear, Right 10 ± Complied Front, Left, Rear, Right 10 ± Complied Page 36 of 79 RFI Global Services Ltd.
37 POSITION TO OBJECT IN VICINITY OF EUT (VERTICAL COUPLING PLANE) Test Points No. Attempted Test Voltage (kv) Notes Result Front, Left, Rear, Right 10 ± Complied Front, Left, Rear, Right 10 ± Complied NOTE(S) 1 Contact discharges were attempted at this point and were achieved. The EUT continued to operate with no loss of function or change of state. 2 Air gap discharges were attempted at this point, but due to the build of the EUT, discharges were not achieved. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL M172 Electronic Environmental Monitor BA Jul A1420 Vertical Coupling Plane None Stated Calibration not required A1934 Discharge Network None Stated Calibration not required A1935 Discharge Carbon Brush None Stated Calibration not required G090 ESD Simulator NSG Apr A1516 Universal Radio Communications Tester CMU 200 Calibration not required RFI Global Services Ltd. Page 37 of 79
38 ELECTROSTATIC DISCHARGE - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 6 EUT: Maestro 100evo TEMPERATURE: 21 C to 21 C TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 39 % to 39 % DATE OF TEST: 16 Oct 2010 ATMOSPHERIC PRESSURE: 1006 mb to 1006 mb UNCERTAINTY (±): 95% confidence level AIR CONTACT LIMIT: 8 kv PERFORMANCE CRITERIA: Criterion TR/TT DIRECT CONTACT LIMIT: 4 kv TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 1995 including Amendment A1: 1998 and Amendment A2: 2001 TITLE: Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: GSM 900 Idle FUNCTION(S) MONITORED: A spectrum analyser was used to monitor for unintentional transmissions from the EUT DIRECT CONTACT TO EUT Test Points No. Attempted Test Voltage (kv) Notes Result 1 to 8 10 ± Complied 1 to 8 10 ± Complied AIR GAP TO EUT Test Points No. Attempted Test Voltage (kv) Notes Result A to D 10 ± Complied A to D 10 ± Complied A to D 10 ± Complied POSITION TO OBJECT IN VICINITY OF EUT (HORIZONTAL COUPLING PLANE) Test Points No. Attempted Test Voltage (kv) Notes Result Front, Left, Rear, Right 10 ± Complied Front, Left, Rear, Right 10 ± Complied Page 38 of 79 RFI Global Services Ltd.
39 POSITION TO OBJECT IN VICINITY OF EUT (VERTICAL COUPLING PLANE) Test Points No. Attempted Test Voltage (kv) Notes Result Front, Left, Rear, Right 10 ± Complied Front, Left, Rear, Right 10 ± Complied NOTE(S) 1 Contact discharges were attempted at this point and were achieved. The EUT continued to operate with no loss of function or change of state. 2 Air gap discharges were attempted at this point, but due to the build of the EUT, discharges were not achieved. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL M172 Electronic Environmental Monitor BA Jul A1420 Vertical Coupling Plane None Stated Calibration not required A1934 Discharge Network None Stated Calibration not required A1935 Discharge Carbon Brush None Stated Calibration not required G090 ESD Simulator NSG Apr A1516 Universal Radio Communications Tester CMU 200 Calibration not required RFI Global Services Ltd. Page 39 of 79
40 ELECTROSTATIC DISCHARGE - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 6 EUT: Maestro 100evo TEMPERATURE: 21 C to 21 C TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 39 % to 39 % DATE OF TEST: 16 Oct 2010 ATMOSPHERIC PRESSURE: 1006 mb to 1006 mb UNCERTAINTY (±): 95% confidence level AIR CONTACT LIMIT: 8 kv PERFORMANCE CRITERIA: Criterion TR/TT DIRECT CONTACT LIMIT: 4 kv TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 1995 including Amendment A1: 1998 and Amendment A2: 2001 TITLE: Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: DCS 1800 Allocated FUNCTION(S) MONITORED: A radio communication tester was used to monitor the BLER which was not to exceed 0.01 DIRECT CONTACT TO EUT Test Points No. Attempted Test Voltage (kv) Notes Result 1 to 8 10 ± Complied 1 to 8 10 ± Complied AIR GAP TO EUT Test Points No. Attempted Test Voltage (kv) Notes Result A to D 10 ± Complied A to D 10 ± Complied A to D 10 ± Complied POSITION TO OBJECT IN VICINITY OF EUT (HORIZONTAL COUPLING PLANE) Test Points No. Attempted Test Voltage (kv) Notes Result Front, Left, Rear, Right 10 ± Complied Front, Left, Rear, Right 10 ± Complied Page 40 of 79 RFI Global Services Ltd.
41 POSITION TO OBJECT IN VICINITY OF EUT (VERTICAL COUPLING PLANE) Test Points No. Attempted Test Voltage (kv) Notes Result Front, Left, Rear, Right 10 ± Complied Front, Left, Rear, Right 10 ± Complied NOTE(S) 1 Contact discharges were attempted at this point and were achieved. The EUT continued to operate with no loss of function or change of state. 2 Air gap discharges were attempted at this point, but due to the build of the EUT, discharges were not achieved. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL M172 Electronic Environmental Monitor BA Jul A1420 Vertical Coupling Plane None Stated Calibration not required A1934 Discharge Network None Stated Calibration not required A1935 Discharge Carbon Brush None Stated Calibration not required G090 ESD Simulator NSG Apr A1516 Universal Radio Communications Tester CMU 200 Calibration not required RFI Global Services Ltd. Page 41 of 79
42 ELECTROSTATIC DISCHARGE - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 6 EUT: Maestro 100evo TEMPERATURE: 21 C to 21 C TEST ENGINEER: Gareth Bragg RELATIVE HUMIDITY: 39 % to 39 % DATE OF TEST: 16 Oct 2010 ATMOSPHERIC PRESSURE: 1006 mb to 1006 mb UNCERTAINTY (±): 95% confidence level AIR CONTACT LIMIT: 8 kv PERFORMANCE CRITERIA: Criterion TR/TT DIRECT CONTACT LIMIT: 4 kv TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 1995 including Amendment A1: 1998 and Amendment A2: 2001 TITLE: Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: DCS 1800 Idle FUNCTION(S) MONITORED: A spectrum analyser was used to monitor for unintentional transmissions from the EUT DIRECT CONTACT TO EUT Test Points No. Attempted Test Voltage (kv) Notes Result 1 to 8 10 ± Complied 1 to 8 10 ± Complied AIR GAP TO EUT Test Points No. Attempted Test Voltage (kv) Notes Result A to D 10 ± Complied A to D 10 ± Complied A to D 10 ± Complied POSITION TO OBJECT IN VICINITY OF EUT (HORIZONTAL COUPLING PLANE) Test Points No. Attempted Test Voltage (kv) Notes Result Front, Left, Rear, Right 10 ± Complied Front, Left, Rear, Right 10 ± Complied Page 42 of 79 RFI Global Services Ltd.
43 POSITION TO OBJECT IN VICINITY OF EUT (VERTICAL COUPLING PLANE) Test Points No. Attempted Test Voltage (kv) Notes Result Front, Left, Rear, Right 10 ± Complied Front, Left, Rear, Right 10 ± Complied NOTE(S) 1 Contact discharges were attempted at this point and were achieved. The EUT continued to operate with no loss of function or change of state. 2 Air gap discharges were attempted at this point, but due to the build of the EUT, discharges were not achieved. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL M172 Electronic Environmental Monitor BA Jul A1420 Vertical Coupling Plane None Stated Calibration not required A1934 Discharge Network None Stated Calibration not required A1935 Discharge Carbon Brush None Stated Calibration not required G090 ESD Simulator NSG Apr A1516 Universal Radio Communications Tester CMU 200 Calibration not required RFI Global Services Ltd. Page 43 of 79
44 FAST TRANSIENTS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 6 EUT: Maestro 100evo TEMPERATURE: 23 C to 23 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 26 % to 26 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1013 mb to 1013 mb UNCERTAINTY (±): 95% confidence level LEVEL: ± 0.5 kv PERFORMANCE CRITERIA: Criteria TR/TT BURST PERIOD: 300 ms REPETITION RATE: 5.0 khz BURST DURATION: 15 ms PULSE RISE TIME: 5 ns PULSE DURATION 50 ns TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 2004 TITLE: Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: GSM 900 Allocated FUNCTION(S) MONITORED: A radio communication tester was used to monitor the BLER which was not to exceed 0.01 TEST RESULTS Port Line Under Test Test Voltage (kv) Notes Result DC Power Positive ± Complied DC Power Negative ± Complied DC Power Positive-Negative ± Complied DC Power Positive ± Complied DC Power Negative ± Complied DC Power Positive-Negative ± Complied NOTES N/A During measurement the engineer did not record any specific notes relevant to report. Page 44 of 79 RFI Global Services Ltd.
45 TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL L1003 Wireless Communication Test Set 8960 Calibration not required K0006 ESD and Fast Transient / Burst Immunity Laboratory None Stated Calibration not required M1001 Spectrum Analyser 8594A 8594A Calibration not required C m N-Type Cable FA210A Calibrated before use M1141 Immunity Test System Transient Mar RFI Global Services Ltd. Page 45 of 79
46 FAST TRANSIENTS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 6 EUT: Maestro 100evo TEMPERATURE: 23 C to 23 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 26 % to 26 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1013 mb to 1013 mb UNCERTAINTY (±): 95% confidence level LEVEL: ± 0.5 kv PERFORMANCE CRITERIA: Criteria TR/TT BURST PERIOD: 300 ms REPETITION RATE: 5.0 khz BURST DURATION: 15 ms PULSE RISE TIME: 5 ns PULSE DURATION 50 ns TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 2004 TITLE: Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: GSM 900 Idle FUNCTION(S) MONITORED: A spectrum analyser was used to monitor for unintentional transmissions from the EUT TEST RESULTS Port Line Under Test Test Voltage (kv) Notes Result DC Power Positive ± Complied DC Power Negative ± Complied DC Power Positive-Negative ± Complied DC Power Positive ± Complied DC Power Negative ± Complied DC Power Positive-Negative ± Complied NOTES N/A During measurement the engineer did not record any specific notes relevant to report. Page 46 of 79 RFI Global Services Ltd.
47 TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL L1003 Wireless Communication Test Set 8960 Calibration not required K0006 ESD and Fast Transient / Burst Immunity Laboratory None Stated Calibration not required M1001 Spectrum Analyser 8594A 8594A Calibration not required C m N-Type Cable FA210A Calibrated before use M1141 Immunity Test System Transient Mar RFI Global Services Ltd. Page 47 of 79
48 FAST TRANSIENTS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 6 EUT: Maestro 100evo TEMPERATURE: 23 C to 23 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 26 % to 26 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1013 mb to 1013 mb UNCERTAINTY (±): 95% confidence level LEVEL: ± 0.5 kv PERFORMANCE CRITERIA: Criteria TR/TT BURST PERIOD: 300 ms REPETITION RATE: 5.0 khz BURST DURATION: 15 ms PULSE RISE TIME: 5 ns PULSE DURATION 50 ns TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 2004 TITLE: Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: DCS 1800 Allocated FUNCTION(S) MONITORED: A radio communication tester was used to monitor the BLER which was not to exceed 0.01 TEST RESULTS Port Line Under Test Test Voltage (kv) Notes Result DC Power Positive ± Complied DC Power Negative ± Complied DC Power Positive-Negative ± Complied DC Power Positive ± Complied DC Power Negative ± Complied DC Power Positive-Negative ± Complied NOTES N/A During measurement the engineer did not record any specific notes relevant to report. Page 48 of 79 RFI Global Services Ltd.
49 TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL L1003 Wireless Communication Test Set 8960 Calibration not required K0006 ESD and Fast Transient / Burst Immunity Laboratory None Stated Calibration not required M1001 Spectrum Analyser 8594A 8594A Calibration not required C m N-Type Cable FA210A Calibrated before use M1141 Immunity Test System Transient Mar RFI Global Services Ltd. Page 49 of 79
50 FAST TRANSIENTS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 6 EUT: Maestro 100evo TEMPERATURE: 23 C to 23 C TEST ENGINEER: Eric Phiri RELATIVE HUMIDITY: 26 % to 26 % DATE OF TEST: 20 Oct 2010 ATMOSPHERIC PRESSURE: 1013 mb to 1013 mb UNCERTAINTY (±): 95% confidence level LEVEL: ± 0.5 kv PERFORMANCE CRITERIA: Criteria TR/TT BURST PERIOD: 300 ms REPETITION RATE: 5.0 khz BURST DURATION: 15 ms PULSE RISE TIME: 5 ns PULSE DURATION 50 ns TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 2004 TITLE: Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: DCS 1800 Idle FUNCTION(S) MONITORED: A spectrum analyser was used to monitor for unintentional transmissions from the EUT. TEST RESULTS Port Line Under Test Test Voltage (kv) Notes Result DC Power Positive ± Complied DC Power Negative ± Complied DC Power Positive-Negative ± Complied DC Power Positive ± Complied DC Power Negative ± Complied DC Power Positive-Negative ± Complied NOTES N/A During measurement the engineer did not record any specific notes relevant to report. Page 50 of 79 RFI Global Services Ltd.
51 TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL L1003 Wireless Communication Test Set 8960 Calibration not required K0006 ESD and Fast Transient / Burst Immunity Laboratory None Stated Calibration not required M1001 Spectrum Analyser 8594A 8594A Calibration not required C m N-Type Cable FA210A Calibrated before use M1141 Immunity Test System Transient Mar RFI Global Services Ltd. Page 51 of 79
52 CONDUCTED IMMUNITY - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 8 EUT: Maestro 100evo TEMPERATURE: 19 C to 24 C TEST ENGINEER: Jack Suter RELATIVE HUMIDITY: 34 % to 34 % DATE OF TEST: 18 Oct 2010 ATMOSPHERIC PRESSURE: 1001 mb to 1001 mb UNCERTAINTY (±): ±3.86 db DWELL TIME (s): 1.5 s PERFORMANCE CRITERIA: Criteria CR/CT FREQUENCY RANGE: 0.15 to 80 MHz LEVEL: 3 Vrms SWEEP RATE: x 10-3 decades/s STEP SIZE: 1% log of momentary frequency MODULATION: 80% 1 khz TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 2009 TITLE: Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques - Immunity disturbances, induced by radio-frequency fields COMMENTS The list of actual test frequencies used during these measurements is available on request. DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: DCS 1800 Allocated FUNCTION(S) MONITORED: A radio communication tester was used to monitor the BLER which was not to exceed 0.01 MEASUREMENT RESULTS No. Line Under Test Coupling Method Frequency Band Spot Frequency Level (Vrms) Notes Result 1 DC input CDN 0.15 to 80 MHz - 3 Vrms - Complied NOTES N/A During measurement the engineer did not record any specific notes relevant to report. Page 52 of 79 RFI Global Services Ltd.
53 TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required G W Amplifier 150L 30 Mar G khz to 1 GHz SMG Calibrated as part of system M1164 Power Meter 10 khz to 2 GHz CPW 9670 Calibrated as part of system N0545 Site 8 PC Nov C123 Cable None Stated 22 Feb A db DC/18 GHz/50 Ohm Attenuator Calibrated before use C301 Cable UFA 210A x50 22 Feb C323 Cable UFA 210A x50 Calibrated as part of system C1093 Cable Calibrated as part of system C m N-Type Coaxial Cable FA210A Calibrated as part of system A1163 Attenuator 6 db Calibrated before use C356 Cable UFA210A x70 Calibrated as part of system A Ohm Terminator Calibrated before use A1291 DC3400 Directional Coupler DC3400 Calibrated before use C MHz to18 GHz FA21A1030M5050 Calibrated as part of system RFI Global Services Ltd. Page 53 of 79
54 CONDUCTED IMMUNITY - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 8 EUT: Maestro 100evo TEMPERATURE: 24 C to 24 C TEST ENGINEER: Jack Suter RELATIVE HUMIDITY: 34 % to 34 % DATE OF TEST: 18 Oct 2010 ATMOSPHERIC PRESSURE: 1001 mb to 1001 mb UNCERTAINTY (±): ±3.86 db DWELL TIME (s): 1.5 s PERFORMANCE CRITERIA: Criteria CR/CT FREQUENCY RANGE: 0.15 to 80 MHz LEVEL: 3 Vrms SWEEP RATE: x 10-3 decades/s STEP SIZE: 1% log of momentary frequency MODULATION: 80% 1 khz TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 2009 TITLE: Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques - Immunity disturbances, induced by radio-frequency fields COMMENTS The list of actual test frequencies used during these measurements is available on request. DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: GSM 900 Allocated FUNCTION(S) MONITORED: A radio communication tester was used to monitor the BLER which was not to exceed 0.01 MEASUREMENT RESULTS No. Line Under Test Coupling Method Frequency Band Spot Frequency Level (Vrms) Notes Result 1 DC input CDN 0.15 to 80 MHz - 3 Vrms - Complied NOTES N/A During measurement the engineer did not record any specific notes relevant to report. Page 54 of 79 RFI Global Services Ltd.
55 TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required G W Amplifier 150L 30 Mar G khz to 1 GHz SMG Calibrated as part of system M1164 Power Meter 10 khz to 2 GHz CPW 9670 Calibrated as part of system N0545 Site 8 PC Nov C123 Cable None Stated 22 Feb A db DC/18 GHz/50 Ohm Attenuator Calibrated before use C301 Cable UFA 210A x50 22 Feb C323 Cable UFA 210A x50 Calibrated as part of system C1093 Cable Calibrated as part of system C m N-Type Coaxial Cable FA210A Calibrated as part of system A1163 Attenuator 6 db Calibrated before use C356 Cable UFA210A x70 Calibrated as part of system A Ohm Terminator Calibrated before use A1291 DC3400 Directional Coupler DC3400 Calibrated before use C MHz to 18 GHz FA21A1030M5050 Calibrated as part of system RFI Global Services Ltd. Page 55 of 79
56 CONDUCTED IMMUNITY - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 8 EUT: Maestro 100evo TEMPERATURE: 24 C to 24 C TEST ENGINEER: Jack Suter RELATIVE HUMIDITY: 34 % to 34 % DATE OF TEST: 18 Oct 2010 ATMOSPHERIC PRESSURE: 1001 mb to 1001 mb UNCERTAINTY (±): ±3.86 db DWELL TIME (s): 1.5 s PERFORMANCE CRITERIA: Criteria CR/CT FREQUENCY RANGE: 0.15 to 80 MHz LEVEL: 3 Vrms SWEEP RATE: x 10-3 decades/s STEP SIZE: 1% log of momentary frequency MODULATION: 80% 1 khz TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 2009 TITLE: Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques - Immunity disturbances, induced by radio-frequency fields COMMENTS The list of actual test frequencies used during these measurements is available on request. DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: DCS 1800 Idle FUNCTION(S) MONITORED: A spectrum analyser was used to monitor for unintentional transmissions from the EUT MEASUREMENT RESULTS No. Line Under Test Coupling Method Frequency Band Spot Frequency Level (Vrms) Notes Result 1 DC input CDN 0.15 to 80 MHz - 3 Vrms - Complied NOTES N/A During measurement the engineer did not record any specific notes relevant to report. Page 56 of 79 RFI Global Services Ltd.
57 TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required G W Amplifier 150L 30 Mar G khz to 1 GHz SMG Calibrated as part of system M1164 Power Meter 10 khz to 2 GHz CPW 9670 Calibrated as part of system N0545 Site 8 PC Nov C123 Cable None Stated 22 Feb A db DC/18 GHz/50 Ohm Attenuator Calibrated before use C301 Cable UFA 210A x50 22 Feb C323 Cable UFA 210A x50 Calibrated as part of system C1093 Cable Calibrated as part of system C m N-Type Coaxial Cable FA210A Calibrated as part of system A1163 Attenuator 6 db Calibrated before use C356 Cable UFA210A x70 Calibrated as part of system A Ohm Terminator Calibrated before use A1291 DC3400 Directional Coupler DC3400 Calibrated before use C MHz to 18 GHz FA21A1030M5050 Calibrated as part of system RFI Global Services Ltd. Page 57 of 79
58 CONDUCTED IMMUNITY - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 8 EUT: Maestro 100evo TEMPERATURE: 24 C to 24 C TEST ENGINEER: Jack Suter RELATIVE HUMIDITY: 34 % to 34 % DATE OF TEST: 18 Oct 2010 ATMOSPHERIC PRESSURE: 1001 mb to 1001 mb UNCERTAINTY (±): ±3.86 db DWELL TIME (s): 1.5 s PERFORMANCE CRITERIA: Criteria CR/CT FREQUENCY RANGE: 0.15 to 80 MHz LEVEL: 3 Vrms SWEEP RATE: x 10-3 decades/s STEP SIZE: 1% log of momentary frequency MODULATION: 80% 1 khz TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: EN : 2009 TITLE: Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques - Immunity disturbances, induced by radio-frequency fields COMMENTS The list of actual test frequencies used during these measurements is available on request. DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: GSM 900 Idle FUNCTION(S) MONITORED: A spectrum analyser was used to monitor for unintentional transmissions from the EUT MEASUREMENT RESULTS No. Line Under Test Coupling Method Frequency Band Spot Frequency Level (Vrms) Notes Result 1 DC input CDN 0.15 to 80 MHz - 3 Vrms - Complied NOTES N/A During measurement the engineer did not record any specific notes relevant to report. Page 58 of 79 RFI Global Services Ltd.
59 TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0008 Conducted AC Emissions / Conducted RF immunity Laboratory None Stated Calibration not required G W Amplifier 150L 30 Mar G khz to 1 GHz SMG Calibrated as part of system M1164 Power Meter 10 khz to 2 GHz CPW 9670 Calibrated as part of system N0545 Site 8 PC Nov C123 Cable None Stated 22 Feb A db DC/18 GHz/50 Ohm Attenuator Calibrated before use C301 Cable UFA 210A x50 22 Feb C323 Cable UFA 210A x50 Calibrated as part of system C1093 Cable Calibrated as part of system C m N-Type Coaxial Cable FA210A Calibrated as part of system A1163 Attenuator 6 db Calibrated before use C356 Cable UFA210A x70 Calibrated as part of system A Ohm Terminator Calibrated before use A1291 DC3400 Directional Coupler DC3400 Calibrated before use C MHz to 18GHz FA21A1030M5050 Calibrated as part of system RFI Global Services Ltd. Page 59 of 79
60 VEHICLE TRANSIENTS - TEST RESULTS This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: GENERAL INFORMATION RFI JOB NUMBER: 78797JD02 TEST SITE ID: Site 6 EUT: Maestro 100evo TEMPERATURE: 23 C to 23 C TEST ENGINEER: Nicholas Jones RELATIVE HUMIDITY: 36 % to 36 % DATE OF TEST: 18 Oct 2010 ATMOSPHERIC PRESSURE: 1004 mb to 1004 mb UNCERTAINTY (±): Not applicable PERFORMANCE CRITERIA: Criterion TR/TT OPERATING VOLTAGE (U A): 27 OPERATING VOLTAGE (UA): 24 TEST SPECIFICATION DETAILS The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic standard: REFERENCE: ISO : 2004 TITLE: Road vehicles -- Electrical disturbances from conduction and coupling -- Part 2: Electrical transient conduction along supply lines only COMMENTS None DEVIATIONS FROM TEST SPECIFICATION There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified above). EUT RELATED OPERATING MODE: GSM 900 Allocated FUNCTION(S) MONITORED: A radio communication tester was used to monitor the BLER which was not to exceed 0.01 MEASUREMENT RESULTS PULSE TYPE 1 No. Line Under Test Level (V s) Ri t d (ms) t r (μs) t 1 (s) t 2 (ms) t 3 (μs) No. of Pulses or Test Time Result 1 DC power Ω < Complied 1 PULSE TYPE 2a No. Line Under Test Level (V s) Ri t d (ms) t r (μs) t 1 (s) No. of Pulses or Test Time Result 1 DC power 37 2 Ω Complied PULSE TYPE 2b No. Line Under Test Level (V s) Ri t d (s) t r (ms) t 12 (ms) t 6 (ms) No. of Pulses or Test Time Result 1 DC power 20 0 Ω ± ± ± Complied 1 Page 60 of 79 RFI Global Services Ltd.
61 PULSE TYPE 3a No. Line Under Test Level (V s) Ri t d (μs) t r (ns) t 1 (μs) t 4 (ms) t 5 (ms) No. of Pulses or Test Time Result 1 DC power Ω ± minutes Complied PULSE TYPE 3b No. Line Under Test Level (V s) Ri t d (μs) t r (ns) t 1 (μs) t 4 (ms) t 5 (ms) No. of Pulses or Test Time Result 1 DC power Ω ± minutes Complied PULSE TYPE 4 No. Line Under Test Level (V s) Ri Level (V a) t 7 (ms) t 8 (ms) t 9 (s) t 10 (ms) t 11 (ms) No. of Pulses or Test Time Result 1 DC power Ω Complied NOTE(S) Upon application of the test phenomena the communication link was lost, however when the test phenomena was 1 removed the link could be re-established by the operator. TEST EQUIPMENT USED RFI ID INSTRUMENT DESCRIPTION MODEL NUMBER CALIBRATION DUE INTERVAL K0006 ESD and Fast Transient / Burst Immunity Laboratory None Stated Calibration not required M172 Electronic Environmental Monitor BA Jul G037 NSG 5004 Plug-in NSG Mar G0527 Output resistance unit NSG5026 V Mar G036 NSG 5003 Plug-in NSG Jul G0559 Transient Generator NSG Jul RFI Global Services Ltd. Page 61 of 79
62 8. PHOTOGRAPHS OF EUT This section contains the following photographs: Photo Reference Number PHT\78797JD02\001 PHT\78797JD02\002 PHT\78797JD02\003 PHT\78797JD02\004 Title Test Configuration Photograph - Conducted Emissions Test Configuration Photograph - Radiated Immunity Test Configuration Photograph - Vehicular Transients Test Configuration Photograph - EFT Page 62 of 79 RFI Global Services Ltd.
63 PHT\78797JD02\001 - Test Configuration Photograph - Conducted Emissions RFI Global Services Ltd. Page 63 of 79
64 PHT\78797JD02\002 - Test Configuration Photograph - Radiated Immunity Page 64 of 79 RFI Global Services Ltd.
65 PHT\78797JD02\003 - Test Configuration Photograph - Vehicular Transients RFI Global Services Ltd. Page 65 of 79
66 PHT\78797JD02\004 - Test Configuration Photograph - EFT Page 66 of 79 RFI Global Services Ltd.
67 9. GRAPHICAL TEST RESULTS 9.1. This section contains the graphical results for the measurements listed in Section 2.2. Summary of Test Results (above). Graph Number GPH\78797JD02\001 GPH\78797JD02\002 GPH\78797JD02\003 GPH\78797JD02\004 GPH\78797JD02\005 GPH\78797JD02\006 GPH\78797JD02\007 GPH\78797JD02\008 Title Conducted Emissions (GSM 900 Allocated - 12 VDC) Pre-Scan (0.15 MHz to 30 MHz) Conducted Emissions (GSM 900 Idle - 12 VDC) Pre-Scan (0.15 MHz to 30 MHz) Conducted Emissions (DCS 1800 Allocated - 12 VDC) Pre-Scan (0.15 MHz to 30 MHz) Conducted Emissions (DCS 1800 Idle - 12 VDC) Pre-Scan (0.15 MHz to 30 MHz) Conducted Emissions (DCS 1800 Idle - 24 VDC) Pre-Scan (0.15 MHz to 30 MHz) Conducted Emissions (DCS 1800 Allocated - 24 VDC) Pre-Scan (0.15 MHz to 30 MHz) Conducted Emissions (GSM 900 Allocated - 24 VDC) Pre-Scan (0.15 MHz to 30 MHz) Conducted Emissions (GSM 900 Idle - 24 VDC) Pre-Scan (0.15 MHz to 30 MHz) RFI Global Services Ltd. Page 67 of 79
68 GPH\78797JD02\001 EN55022 Class B Voltage Vehicular LISN scans EN Class B Voltage on Mains QP EN Class B Voltage on Mains AV 45 Level in dbµv k M 2M 3M 4M 5M M 20M 30M Frequency in Hz Page 68 of 79 RFI Global Services Ltd.
69 GPH\78797JD02\002 EN55022 Class B Voltage Vehicular LISN scans EN Class B Voltage on Mains QP EN Class B Voltage on Mains AV 45 Level in dbµv k M 2M 3M 4M 5M M 20M 30M Frequency in Hz RFI Global Services Ltd. Page 69 of 79
70 GPH\78797JD02\003 EN55022 Class B Voltage Vehicular LISN scans EN Class B Voltage on Mains QP EN Class B Voltage on Mains AV 45 Level in dbµv k M 2M 3M 4M 5M M 20M 30M Frequency in Hz Page 70 of 79 RFI Global Services Ltd.
71 GPH\78797JD02\004 EN55022 Class B Voltage Vehicular LISN scans EN Class B Voltage on Mains QP EN Class B Voltage on Mains AV 45 Level in dbµv k M 2M 3M 4M 5M M 20M 30M Frequency in Hz RFI Global Services Ltd. Page 71 of 79
72 GPH\78797JD02\005 EN55022 Class B Voltage Vehicular LISN scans EN Class B Voltage on Mains QP EN Class B Voltage on Mains AV 45 Level in dbµv k M 2M 3M 4M 5M M 20M 30M Frequency in Hz Page 72 of 79 RFI Global Services Ltd.
73 GPH\78797JD02\006 EN55022 Class B Voltage Vehicular LISN scans EN Class B Voltage on Mains QP EN Class B Voltage on Mains AV 45 Level in dbµv k M 2M 3M 4M 5M M 20M 30M Frequency in Hz RFI Global Services Ltd. Page 73 of 79
74 GPH\78797JD02\007 EN55022 Class B Voltage Vehicular LISN scans EN Class B Voltage on Mains QP EN Class B Voltage on Mains AV 45 Level in dbµv k M 2M 3M 4M 5M M 20M 30M Frequency in Hz Page 74 of 79 RFI Global Services Ltd.
75 GPH\78797JD02\008 EN55022 Class B Voltage Vehicular LISN scans EN Class B Voltage on Mains QP EN Class B Voltage on Mains AV 45 Level in dbµv k M 2M 3M 4M 5M M 20M 30M Frequency in Hz RFI Global Services Ltd. Page 75 of 79
76 10. TEST CONFIGURATION DRAWINGS This section contains the Test Configuration Drawings for the measurements listed in Section 7: Measurements, Examinations and Derived Results. Test Configuration Reference Number DRG\78797JD02\001 DRG\78797JD02\002 DRG\78797JD02\003 Title ESD Test Point Photograph: Test Points 1 to 5, A and B ESD Test Point Photograph: Test Points 6 to 8, C and D Schematic diagram of the EUT, support equipment and interconnecting cables used for the test Page 76 of 79 RFI Global Services Ltd.
77 DRG\78797JD02\001 - ESD Test Point Photograph: Test Points 1 to 5, A and B RFI Global Services Ltd. Page 77 of 79
78 DRG\78797JD02\002 - ESD Test Point Photograph: Test Points 6 to 8, C and D Page 78 of 79 RFI Global Services Ltd.
TEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Test of: Smart Gears Limited, Micro-tracker MT-01 To: 47CFR15.109 and RSS-GEN Issue 3 December 2010 Test Report Serial No: RFI-EMC-RP81827JD05A This test report is issued under
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: Ingenico France, IWL252-01T1535A To: 47CFR15.107, 47CFR15.109 and RSS-GEN Issue 3 December 2010 Test Report Serial No: RFI-EMC-RP82173JD02A V2.0 Version
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Test of: C-Track NX55 To: EN 300 440-1 V1.6.1 (2010-08) in accordance with EN 300 440-2 V1.4.1 (2010-08) Test Report Serial No.: RFI-RPT-RP84347JD02A This Test Report Is Issued
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Test of: CIBS To: FCC Part 15.247: 2008 Subpart C, RSS-210 Issue 7 June 2007 & RSS-Gen Issue 2 June 2007 Test Report Serial No: RFI/RPT2/RP75103JD05A Supersedes Test Report
More informationTEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.
TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD. Test Of: Wood & Douglas Ltd ST500 Transmitter Test Report Serial No: RFI/EMCB2/RP39403B This Test Report supersedes RFI Test Report No.: RFI/EMCB1/RP39403B
More informationEMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009
Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203
More informationReport for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027
Report for Excelsys on EMC Measurements for 6Xgen Purchase Order: by email Project Number EMT08J027 Tom O Brien, Engineering Director ElectroMagnetic Technologies Ltd, Cork, June 2007 Executive Summary
More informationReport for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B
Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBL SERVICES LTD Partial Test of: 5 To: FCC Part 5.247: 2008 Subpart C Test Report Serial No: RFI/RPT/RP79JD03 This Test Report Is Issued Under The uthority Of Brian Watson, Operations Director:
More informationUnilab(Shanghai) Co.,Ltd. Report No. : UL CE010-1 Page 1 of 27 EMC TEST REPORT
Report No. : UL15820160902CE010-1 Page 1 of 27 EMC TEST REPORT Product Name : GSM/WCDMA Wireless Module Model No. : SIM5300EA Prepared for: Shanghai Simcom Wireless Solutions Co., Ltd BuildingA, SIM Technology
More informationEMC Test Report. Report Number: M030826
Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report
More informationEMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight
EMC Bayswater Pty Ltd 52 Holloway Drive Bayswater, Victoria, 3153, Australia Telephone: +61 3 9762 4111 Facsimile: +61 3 9762 8519 Email: sales@emcbayswater.com.au ABN: 49 112 221 333 EMC COMPLIANCE REPORT
More informationCONFORMANCE TEST REPORT FOR EN /-6
CONFORMANCE TEST REPORT FOR EN 301489-1/-6 Client: Product: Model: Manufacturer/supplier: Aztech Systems Limited DECT Phone H315-S1 (FP) Aztech Systems Limited Date test item received: 2006/05/09 Date
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBL SERVICES LTD Partial Test of: BTM4 To: FCC Part 5.247: 08 Subpart C, RSS- Issue 7 June 07 & RSS-Gen Issue 2 June 07 Test Report Serial No: RFI/RPT/RP78JD03 This Test Report Is Issued Under
More informationTest Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,
Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of, EN 301 489-1 V1.8.1 Electromagnetic compatibility and
More informationTABLE OF CONTENTS. Report No.: SZ E01 1. GENERAL INFORMATION... 3
TABLE OF CONTENTS 1. GENERAL INFORMATION... 3 1.1 EUT Description... 3 1.2 Test Standards and Results... 3 1.3 Test Equipments Used... 4 1.4 Facilities and Accreditations... 4 1.4.1 Facilities... 4 1.4.2
More informationELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 1 / 35 TEST REPORT Responsible Party Manufacturer Description of Product Trade Name : Huan Vu Enterprise Co., Ltd. : Huan Vu Enterprise Co.,
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25
15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE
More informationEN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd
Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBL SERVICES LTD Partial Test of: Motorola Point to Point Fixed Wireless Solutions PTP58 5.8 GHz band Wireless Ethernet Bridge To: FCC Part 5.47: 8 Subpart C, RSS- Issue 7 June 7 & RSS-Gen Issue
More informationEN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass
Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz
More informationHarmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass
Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27
15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE
More informationDiscontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz
Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationEMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan
Page 1 of 32 EMC TEST REPORT Report No.: TS11020117-EME Model No.: NS-PSE, NS-POINTED, NS-PSQUARE, NS-PF-S, NS-PT, NS-PR, NS-PU, NS-PF-H, NS-BALIBA, NS-FLEXMA Issued Date: Mar. 01, 2011 Applicant: NORTE
More informationELECTRONICS TESTING CENTER, TAIWAN
File No.: 09-06-MAS-242-03 EMC TESTING DEPARTMENT Page:1/12 CONFORMANCE TEST REPORT FOR EN 301489-1 / -17 Report No.: 09-06-MAS-242-03 Client: Product: Model: Manufacturer/supplier: Ezurio Limited. Bluetooth
More information2620 Modular Measurement and Control System
European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic
More informationEMC test report AU01+E04
Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E04 This test report may not be copied or published in a part without the written authorization of
More informationEN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments
EMC Page 3 / 33 Test report No.: EN 61000-6-3:2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: 2013-10-16
More informationEMC VERIFICATION SUMMARY Report No.: SZHH
EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA
More informationDraft ETSI EN V1.2.1 ( )
Draft EN 300 683 V1.2.1 (1999-07) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC)
More informationBS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C
Page 1 of 23 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel
More informationEMC Test Report. Report No.: AGC EE01 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.
Page 1 of 38 EMC Test Report PRODUCT DESIGNATION BRAND NAME MODEL NAME CLIENT : Dual Band Mobile Radio : VGC : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.,LTD DATE
More informationBS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE
Page 1 of 18 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel
More informationETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.
ETSI EN 301 489-1 V2.2.0 (2017-03) ETSI EN 301 489-3 V2.1.1 (2017-03) TEST REPORT For United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT Model: XT-10P Report Type: Amended Report
More informationShenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20
Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC125641 Page: 1 of 20 EMC Test Report Application No. : TB12114299 Applicant : Newmb Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : USB HUB
More informationEMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.
DONGGUAN FIT-WATCH CO., LTD. EMC REPORT Prepared For : DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province Product Name : Trade Name : Model
More informationEMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.
Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial
More informationEMI T E S T R E P O R T
EMI T E S T R E P O R T - FCC Part 15B - Test Report No. : T38935-00-02TK 27. November 2014 Date of issue Type / Model Name : One Touch Select Plus Flex Product Description : Blood glucose meter with Bluetooth
More informationNemko-CCL, Inc West Alexander Street Salt Lake City, UT
Nemko-CCL, Inc. 1940 West Alexander Street Salt Lake City, UT 84119 801-972-6146 Test Report Declaration of Conformity Test Of: MICRO-RM2.4 Test Specifications: EN 301 489-1 V1.9.2 (2011-09) as specified
More informationTABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46
TABLE OF CONTENTS 1. GENERAL INFORMATION...5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...5 1.2 OBJECTIVE...5 1.3 RELATED SUBMITTAL(S)/GRANT(S)...5 1.4 TEST METHODOLOGY...5 1.5 TEST FACILITY...5
More informationEN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A
Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
TEST REPORT FROM RFI GLOBAL SERVICES LTD Serial No: RFI/RPTE2/RP49117JD07A Supersedes Serial No: RFI/RPTE1/RP49117JD07A This Is Issued Under The Authority Of Michael Derby, Wireless Radio Performance Group
More informationPage: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003
Page: 1 of 20 EMC TEST REPORT Reference No. Applicant : WT05060412 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Cable Standards Model No : UAS111-M, UAS111, UAS112 : EN55022:1998+A2:2003
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Test Report Serial No: RFI/RPTE2/RP48909JD015A Supersedes Test Report Serial No: RFI/RPTE1/RP48909JD015A This Test Report Is Issued Under The Authority Of Michael Derby, Radio
More informationTest. Report. Manufacturer. Model No. FCC ID. Technology. and. 1. This. 3. This. pp John Newell. as UL. Date of Issue: 28 May 2013.
Test Report TESTT REPORT No. : UL-RPT-RP89265JD7 V3. Manufacturer Model No. FCC ID IC Certification No. Technology Test Standard(s) : & R Cambridge Ltd (RCM) : L22Y : YONDNW- : 792 -DNW : Bluetooth Basic
More informationEMISSION TEST REPORT
Page 1 of 23 EMISSION TEST REPORT Test Report No. Applicant Address Manufacturer Address Type of Equipment Model Name Serial number Total page of Report : E05OR-057 : Win4NET Co., Ltd. : KOLON Digital
More informationEMC standards. Presented by: Karim Loukil & Kaïs Siala
Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards
More informationITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA
Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU
More informationTEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed
17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:
More informationPARTIAL RADIATED EMISSIONS AND RADIATED IMMUNITY TEST REPORT
ELECTRICAL TESTING 0839.01 Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: mail@hermonlabs.com PARTIAL RADIATED EMISSIONS AND
More informationTest Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification
Test Report: 5R46150.1 Applicant: Equipment Under Test: Model Number: In Accordance With: Tested By: Nanoptix Inc. 699 Champlain Street Dieppe, New Brunswick E1A 1P6 Spill Proof Cuts SPC FCC 47 CFR Part
More informationENGINEERING TEST REPORT #: A LSR JOB #: C-2411
W66 N220 Commerce Court Cedarburg, WI 53012 Phone: 262.375.4400 Fax: 262.375.4248 www.lsr.com Compliance Testing of: RM186-SM Test Date(s): 4-12-16 4-25-16 Prepared For: Attention: N. Zach Hogya Laird
More informationFCC DoC TEST REPORT To: PARTICLE INDUSTRIES, INC To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: -
FCC DoC TEST REPORT To: PARTICLE INDUSTRIES, INC To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: - 94107 Fax: -- Fax: - E-mail: -- E-mail: - Folder No.: BVCZ16FE005ETHS-B
More informationTest Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification
Test Report: 4R08185.1 Applicant: Equipment Under Test: Nanoptix Inc. 699 Champlain Street Dieppe, New-Brunswick E4P 8L6 EZ-Tear FX Model Number: 102103 In Accordance With: FCC 47 CFR Part 15, Subpart
More informationTest Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013
More informationPrepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by
EMC TEST REPORT For KST DIGITAL TECHNOLOGY LIMITED Coreless Servo Model No.: X12-508 Additional Model No.: DS215MG, DS315MG, DS213MG, DS313MG, DS12C, DS12T, X12-306 Prepared for Address : KST DIGITAL TECHNOLOGY
More informationSTC Test Report. Date : Page 1 of 13 No. : HM161169
Date : 2009-05-11 Page 1 of 13 Applicant (ATS001): Atech Scientific Measurement Limited. Room A-C, 18 Floor, Luk Hop Ind. Bldg, 8 Luk Hop Street, Kowloon Manufacturer: Atech Scientific Measurement Limited.
More informationEUROPEAN pr ETS TELECOMMUNICATION November 1995 STANDARD
DRAFT EUROPEAN pr ETS 300 683 TELECOMMUNICATION November 1995 STANDARD Source: ETSI TC-RES Reference: DE/RES-09007 ICS: 33.060.20, 33.100 Key words: EMC, radio, short range, testing Radio Equipment and
More informationEUROPEAN ETS TELECOMMUNICATION November 1997 STANDARD
EUROPEAN ETS 300 826 TELECOMMUNICATION November 1997 STANDARD Source: ERM Reference: DE/ERM-EMC-014 ICS: 33.020 Key words: Broadband, data, EMC, HIPERLAN, radio, system, testing, transmission Electromagnetic
More informationCENTRE OF TESTING SERVICE INTERNATIONAL
CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00097-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China Report
More informationTRANSMITTER MODEL: KAS-2030M
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for TRANSMITTER MODEL: KAS-2030M Prepared for WILDLIFE TECHNOLOGIES 115 WOLCOTT STREET MANCHESTER, NEW HAMPSHIRE 03103 Prepared by: KYLE FUJIMOTO Approved
More informationEMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8
EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 Prepared for Address : ShenZhen ZhangQing Electronic LTD :
More informationTEST REPORT. Test Report No. : UL-RPT-RP JD02A V3.0. Date of Issue: 06 October 2017
Test Report No. : UL-RPT-RP11327903JD02A V3.0 Manufacturer : Kontakt Micro-Location Sp. z o.o. Model No. : Kontakt Smart Beacon 2 FCC ID : 2ADAO-SB2-V250 Technology : Bluetooth Low Energy Test Standard(s)
More informationEMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS
EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by
More informationEN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017
EN 301 489-17 v3.1.1 TEST REPORT FOR Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017 Prepared for Texas Instrument 2900 Semiconductor Drive Santa
More informationReport on the EMC Testing. For. Exception EMS Ltd. RBK-ILS Processor. Report No. TRA A. 29 th April 2016
Report on the EMC Testing For Exception EMS Ltd On RBK-ILS Processor Report No. TRA-028046-36-00A 29 th April 2016 RF657 7.0 Report Number: Copy Number: TRA-028046-36-00A PDF REPORT ON THE EMC TESTING
More informationEMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.
EMC TEST REPORT REPORT NO. : RM110613E07 MODEL NO. : M-R0027 RECEIVED : June 13, 2011 TESTED : June 17, 2011 ISSUED : June 22, 2011 APPLICANT : LOGITECH FAR EAST LTD. ADDRESS : #2 Creation Rd. 4, Science-Based
More informationQI HARDWARE INC. Ben NanoNote. Model: Ben NanoNote September Report No.: (This report supersedes NONE)
QI HARDWARE INC. Ben NanoNote September 24 2009 Report No.: (This report supersedes NONE) Modifications made to the product : See page 6 This Test Report is Issued Under the Authority of: Andy.Hao Compliance
More informationSGS United Kingdom Ltd. International Electrical Approvals. Electromagnetic Compatibility. RF Card Entry System. PAC International Ltd.
South Industrial Estate Bowburn Co. Durham DH6 5AD United Kingdom Tel: +44 (0) 191 377 2000 Fax: +44 (0) 191 377 2020 email: sgsiea@sgs.com SGS United Kingdom Ltd. International Electrical Approvals Electromagnetic
More informationTEST REPORT. Table of Contents
Page:2 of 43 Table of Contents 1. DOCUMENT POLICY AND TEST STATEMENT... 4 1.1 DOCUMENT POLICY... 4 1.2 TEST STATEMENT... 4 2. DESCRIPTION OF EUT AND TEST MODE... 4 2.1 GENERAL DESCRIPTION OF EUT... 4 2.2
More informationTest Verification of Conformity
Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Test Verification of Conformity On the basis of the referenced
More informationElectromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E
Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS1308-1809-W2E Customer Customer's representative In the capacity of Reference number
More informationBy order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China
4317137.50 EMC Test report for LED Fixed luminaires Models LED12036-1R, LED12036-2TU, LED120363R, LED12036-4TU2, LED12036-6TR, LED12036-1R CHR, LED12036-2TU CHR, LED12036-3R CHR, LED12036-4TU2 CHR, LED12036-6TR
More informationTEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen
To: TEST REPORT No.: (5216)033-0360(A) PARTICLE INDUSTRIES, INC TEST REPORT To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: - 94107 Fax: -- Fax: - E-mail: -- E-mail:
More informationEN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U
EN 301 489-17 v1.2.1 (2002-08) TEST REPORT FOR 802.11n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U11615-3 ISSUE DATE: FEBRUARY 29, 2008 Prepared for ATHEROS COMMUNICATIONS, INC.
More informationPage 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.
Page 1 of 20 FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER Equipment Under Test [EUT]: Model Number: Applicant: FCC ID : Radio Controlled Tank FH002 Zhongshan Fu Hai Electronics
More informationTEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen
To: TEST REPORT No.: (5216)033-0357(A) PARTICLE INDUSTRIES, INC TEST REPORT To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: - 94107 Fax: -- Fax: - E-mail: -- E-mail:
More informationSTC Test Report. Date: Page 2 of 25 No.: MH The Hong Kong Standards and Testing Centre Ltd.
Date: 2013-05-22 Page 2 of 25 CONTENT: Cover Page 1 of 25 Content Page 2 of 25 1.0 General Details 1.1 Equipment Under Test [EUT] Page 3 of 25 Description of sample(s) 1.2 Description of EUT operation
More informationQI HARDWARE INC. Ben NanoNote. Model: Ben NanoNote September Report No.: (This report supersedes NONE)
QI HARDWARE INC. Ben NanoNote September 24 2009 Report No.: (This report supersedes NONE) Modifications made to the product : See page 6 This Test Report is Issued Under the Authority of: Andy.Hao Compliance
More informationCTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT
CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CNB3150602-00399-E 2/F., South Tower, Huoju Building, No.181, Canghai Road,
More informationAPPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba
FCC ID. AZPT10CG-24G Page 1 of 56 APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba Prepared for : Futaba Corporation 1080
More informationTEST REPORT. Table of Contents
Page:2 of 24 Table of Contents 1. DOCUMENT POLICY AND TEST STATEMENT... 3 1.1 DOCUMENT POLICY...3 1.2 TEST STATEMENT...3 2. DESCRIPTION OF EUT AND TEST MODE... 4 2.1 GENERAL DESCRIPTION OF EUT...4 2.2
More informationEMC TEST REPORT. according to
EMC TEST REPORT according to European Standard EN 55022:2006/A1:2007 Class B, EN 61000-3-2:2006, EN 61000-3-3:1995/A1:2001/A2:2006, EN 55024:1998/A1:2001/A2:2003 (IEC 61000-4-2:Edition 1.2:2001-04, IEC
More informationEMC TEST REPORT RADISYS CORPORATION. Tel: Fax:
EMC TEST REPORT Report No.: Product: Model No. : FCC2012-8029E GSM Tracker PRIME AT PLT Brand Name: PRIME Applicant: Address: Issued by: Lab Location: RADISYS CORPORATION 601 North Congress Ave Suite 439,
More informationLaird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017
A Test Report # 317241 Equipment Under Test: RM024 Test Date(s): June 9 and June 21, 2017 Prepared for: Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI 53012 Report Issued by: Adam Alger,
More informationD. Guarnone (verifier)
TEST REPORT Title 47-Telecommunication Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart B - Unintentional Radiators Report Reference No....354297-4TRFFCC
More informationTEST REPORT... 1 CONTENT...
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2
More informationTEST REPORT. Test Report No. : UL-RPT-RP JD03A V3.0. Date of Issue: 14 September pp John Newell Quality Manager, UL VS LTD
Test Report No. : UL-RPT-RP07443JD03 V3.0 Manufacturer : pple Inc. Model No. : 0 FCC ID : BCG0 Technology : Bluetooth Basic Rate & EDR Test Standard(s) : FCC Parts 5.7, 5.9(a) & 5.247. This test report
More informationCE EMC Test Report. : Class 1 Bluetooth Data Module : BT740-SA, BT730-SA, BT740-SC, BT730-SC
CE EMC Test Report Equipment Model No. Brand Name Applicant : Class 1 Bluetooth Data Module : BT740-SA, BT730-SA, BT740-SC, BT730-SC : Laird : Laird Technologies Address : 11160 Thompson Ave. / Lenexa,
More informationDiscontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz
Reference No.: WTU15U0933879E Page 2 of 45 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationSTC Test Report. The Hong Kong Standards and Testing Centre Ltd.
Date: 2011-11-15 Page 2 of 15 CONTENT: Cover Page 1 of 15 Content Page 2 of 15 1.0 General Details 1.1 Equipment Under Test [EUT] Page 3 of 15 Description of sample(s) 1.2 Description of EUT operation
More informationEMI -- T E S T R E P O R T
Registration No. DAT-P-207/05 EMI -- T E S T R E P O R T - FCC Part 15B - Test Report No. : T32619-00-04HU 24. July 2008 Date of issue Type / Model Name : R-PO7470 Product Description : Handheld Reader
More informationCE CONFORMANCE REPORT
Accredited Testing Laboratory under the terms of ISO/IEC 17025 CE CONFORMANCE REPORT EMC DIRECTIVE 2004/108/EC for PRODUCT: HIGH DEFINITION NETWORK CAMERA MODEL NAME: LND5110 AUTHORIZED LG Electronics
More informationEN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U
EN 301 489-17 v1.2.1 (2002-08) TEST REPORT FOR 802.11b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U10459-6 ISSUE DATE: JULY 31, 2006 Prepared for ATHEROS COMMUNICATIONS, INC. 5480 GREAT
More informationBUREAU VERITAS. itaste svd
BUREAU VERITAS TEST REPORT No.: (5213)095-0238 TEST REPORT To: INNOKIN TECHNOLOGY CO., LTD I Fax: I -- Attn: -- I -- I Address: Buildinq 6, XinXinTian Industrial Park, XinSha Road, Sha.Jinq street, ShenZhen,
More informationEMC Test report for LED Panel Light Models , , , , ,
4326247.50 EMC Test report for LED Panel Light Models 000529, 000530, 000531, 000532, 000535, 000536 Guangzhou, date of issue: 2016-02-24 Author:Jazz Liang By order of Marvo Verlichting B.V. at Hoogeveen,
More informationTest Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller
Test Report Applicant: Product Name: Brand Name: Model No.: Apricus Solar Co., Ltd. Multi-Function Differential Controller Apricus MFC-1 Date of Receipt : Jan. 04, 2012 Date of Test: Jan. 04, 2012 Date
More informationGuangdong East Power Co., Ltd. Uninterruptible Power Systems
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Uninterruptible Power Systems EAST EA8806, EA8804 Date of Receipt : Nov. 01, 2012 Date of Test: Nov. 03, 2012
More informationEUROPEAN pr ETS TELECOMMUNICATION January 1997 STANDARD
DRAFT EUROPEAN pr ETS 300 329 TELECOMMUNICATION January 1997 STANDARD Second Edition Source: ETSI TC-RES Reference: RE/RES-09036 ICS: 33.020 Key words: DECT, EMC, radio, testing Radio Equipment and Systems
More information