This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation
|
|
- Donald Harmon
- 6 years ago
- Views:
Transcription
1 Annex to declaration accreditation (scope accreditation) Locations where activities are performed under accreditation Location Abbreviation/ location code Head Location Vijzelmolenlaan 5 & GX oerden The Netherlands On-site O Electromagnetic Compatibility (EMC): Automotive emission measurements 1 Electrical/ sub-assembly Conducted Emissions, Voltage method (AN) 150 khz to 108 MHz document 877 CISPR 25 Ford FMC1278, section CE420 Ford EMC-CS-2009, section CE420 GM Conducted Emissions, Current method (Current Probe) 150 khz to 108 MHz 3 Radiated Emissions, Anechoic Chamber method 150 khz to 2,5 GHz 4 Motor vehicles Radiated Emissions, Semi Anechoic Chamber method 30 MHz to 1000 MHz document 879 CISPR 25 document 887 CISPR 25 97/24/EC, chapter 8, Annex V and VI ECE Regulation 10, Annex 7 and 8 Ford FMC1278, section RE310 Ford EMC-CS-2009, section RE310 GM3097 document 885 CISPR 12 97/24/EC, chapter 8, Annex II and III ECE Regulation 10, Annex 4 and 5 This annex has been approved by the Board the Dutch Accreditation Council, on its behalf, J.A..M. de Haas Director Operations Dutch Accreditation Council RvA Page 1 8
2 Annex to declaration accreditation (scope accreditation) Electromagnetic Compatibility (EMC): Automotive immunity tests 5 Electrical/ subassembly Radiated Immunity, Anechoic Chamber method 200 MHz to 4 GHz up to 200 V/m 1,2 to 1,4 GHz and 2,7 to 3,1 GHz up to 300 V/m document 891 ISO /24/EC, chapter 8, Annex VII ECE Regulation 10, Annex 9 Ford FMC1278, section RI114 Ford EMC-CS-2009, section RI114 (radar limited to 300 V/m) GM3097 (radar limited to 300 V/m) 6 Bulk Current Injection method 100 khz to 1 MHz, up to 150 ma 1 to 400 MHz, up to 300 ma 7 Electro Static Discharge immunity (ESD) Contact discharge: kv Air discharge: kv 8 Electrical transient conduction along supply lines only 9 Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines 10 Motor vehicles Radiated Immunity, Semi Anechoic Chamber method 20 MHz to 80 MHz up to 30 V/m 80 MHz to 4 GHz up to 50 V/m document 875 ISO /24/EC, chapter 8, Annex VII ECE Regulation 10, Annex 9 Ford FMC1278, section RI112 Ford EMC-CS-2009, section RI112 GM3097 document 881/1790 ISO Ford FMC1278, section CI280 Ford EMC-CS-2009, section CI280 GM3097 document 882, 883 ISO ECE Regulation 10, Annex 10 document 884 ISO document 889 ISO /24/EC, Chapter 8, Annex IV ECE Regulation 10, Annex 6 Dutch Accreditation Council RvA Page 2 8
3 Annex to declaration accreditation (scope accreditation) Electromagnetic Compatibility (EMC): Emission measurements 11 Electric- and Conducted Emissions, Voltage method (AMN) 9 khz to 30 MHz document 850 EN , CISPR 14-1 EN 55015, CISPR 15 EN 55022, CISPR Conducted Emissions, Voltage method (AAN) 150 khz to 30 MHz 13 Conducted Emissions, Voltage method (Voltage probe) 150 khz to 30 MHz 14 Conducted Emissions, Current method (Current probe) 150 khz to 30 MHz 15 Conducted Emissions, Disturbance power method (Absorber clamp) 30 MHz to 300 MHz 16 Radiated Emissions, Open Area Test Site / Semi Anechoic Chamber method, 9 KHz to 1GHz 17 Radiated Emissions, Full Anechoic Chamber method 30 MHz to 8GHz 18 Radiated Emissions, Loop Antenna System (LAS) method 9 khz to 30 MHz document 1796 EN 55022, CISPR 22, EN 55032, CISPR 32 document 852 EN , CISPR 14-1 EN 55015, CISPR 15 document 848 EN 55022, CISPR 22 document 854 EN EN , CISPR 14-1 document 841/868 EN EN 55022, CISPR 22 document 864 EN EN 55022, CISPR 22 document 866 EN EN 55015, CISPR 15 Dutch Accreditation Council RvA Page 3 8
4 Annex to declaration accreditation (scope accreditation) 19 Electric- and Harmonic Current Emissions 0 Hz to 2 khz document 862 EN-IEC Voltage Fluctuations and Flicker document 860 EN-IEC Electromagnetic Compatibility (EMC): Immunity tests 21 Electric- and Electro Static Discharge immunity (ESD) Contact discharge: kv Air discharge: kv document 859 EN-IEC Radiated electromagnetic field immunity, Anechoic Chamber method 26 MHz to 80 MHz: 3 V/m 80 MHz to 4 GHz: 30 V/m 4 GHz to 6 GHz: 10 V/m 23 Electrical Fast Transient/burst (EFT) immunity document 872 EN-IEC document 858 EN-IEC Surge immunity document 874 EN-IEC Immunity to conducted disturbances 150 khz to 230 MHz 30 Vrms document 856 EN-IEC Power frequency magnetic field immunity document 1829 EN-IEC Voltage dips, short interruptions and voltage variations immunity 50 Hz document 1852 EN-IEC Temperature and Humidity tests 28 Electrical s,, components and installations Cold test type Ab and Ad Time: Up to 200 hours Temp: -25 up to +5 C Humidity: 0% (up to 0 C) 50% above 0 C EN-IEC Dry heat test type Bb and Bd Time: Up to 200 hours Temp: +25 up to +160 C Humidity: 20-50% EN-IEC Dutch Accreditation Council RvA Page 4 8
5 Annex to declaration accreditation (scope accreditation) 30 Electrical s,, components and installations Damp heat cycle Time: Up to 200 hours Temp: +25/+55 C Humidity: 90-98% EN-IEC Composite T/H cycle Time: Up to 300 hours Temp: -10 up to +65 C Humidity: 50-98% 32 Damp heat type Ca and Cb. Time: Up to 200 hours Temp:+25 up to +45 C Humidity: 80-98% EN-IEC EN-IEC Electrical Safety tests and measurements 33 Electrical s, Input power measurement document 1039 & O 34, components and installations Creepage and clearance measurement document 1029 & O EN-IEC Distance through insulation measurement document 1022 & O 36 Stability measurement document 1047 & O 37 Mechanical strength housing tests: Vertical (steel ball) & spring hammer tests (IK2 IK9) Free Fall tests Push / force tests document 1031 EN-IEC , EN-IEC , EN-IEC 62262, EN-IEC60065: cl , , 9.1.7, 12.4, EN-IEC 60335: cl , EN-IEC 60598: cl , EN-IEC 60601: 5.9.2, , , EN-IEC 60950: cl , 4.2.2, 4.2.3, 4.2.4, 4.2.6, EN-IEC 61010: cl , 8.2, 8.3 & O 38 (Earth) Leakage current measurement document 1035 EN-IEC & O 39 Abnormal operation and single fault conditions document 1020 & O Dutch Accreditation Council RvA Page 5 8
6 Annex to declaration accreditation (scope accreditation) 40 Electrical s,, components and installations Capacitance discharge / residual voltage measurement document 1043 & O 41 Earth resistance measurement document 1033 & O 42 Reverse current lithium battery measurement document 1045 EN-IEC & O 43 Dielectric and electric strength test document 1027 EN-IEC , EN , EN & O 44 Insulation resistance test document 1037 & O 45 Temperature test document Degree protection provided by enclosures (IP) IPx3, IPx4, IPx5 IP0x, IPx0, IP1x, IP2x, IP3x, IP4x document 1024 EN-IEC Durability and legibility labeling test document 1414 & O 48 Household appliances and similar apparatus Measurement methods electromagnetic fields with regard to human exposure document 1543 EN-IEC & O 49 Medical Electrical Equipment Defibrillation pro applied parts: - Defibrillation protection (common mode and differential mode) - Energy reduction test document 1821 EN-IEC :2006 +A1:2013, cl EN-IEC :2014, cl EN-IEC :2015, cl ECG functional tests (essential performance / protection against hazardous output) document 1584 EN-IEC :2015, cl EN-IEC :2014, cl EN-IEC :2015, cl Dutch Accreditation Council RvA Page 6 8
7 Annex to declaration accreditation (scope accreditation) Electromagnetic Compatibility (EMC): FCC emission measurements 51 Electric- and, unintentional radiators Conducted Emissions, Voltage method (AMN) 10 khz to 30 MHz 52 Radiated Emissions, Open Area Test Site / Semi Anechoic Chamber method 30 MHz to 8 GHz document 911 ANSI C63.4 FCC MP-5 47 CFR 15, 47 CFR 18 document 913/1129 ANSI C63.4 FCC MP-5 47 CFR 15, 47 CFR 18 Electromagnetic Compatibility (EMC): Emission measurements on-site 53 Electric- and Conducted Emissions, Voltage method (LISN AMN) 150 khz to 30 MHz document 899 & O 54 Conducted Emissions, Voltage method (Voltage probe) 150 khz to 30 MHz 55 Radiated Emissions, 30 MHz to 1GHz document 901 document 907 EN , CISPR & O & O Electromagnetic Compatibility (EMC): Immunity tests on-site 56 Electric- and Electro Static Discharge immunity (ESD) Contact discharge: kv Air discharge: kv document 906 EN-IEC & O 57 Radiated electromagnetic field immunity, 80 MHz to 1 GHz: 10 V/m 58 Electrical Fast Transient/burst (EFT) immunity up to + 4 kv 59 Immunity to conducted disturbances 150 khz to 80 MHz 10 Vrms document 909 In-house method document 905 EN-IEC document 903 Equivalent to EN-IEC & O & O & O Dutch Accreditation Council RvA Page 7 8
8 Annex to declaration accreditation (scope accreditation) Item a as given below shows the relation between the test activities as mentioned above and the standards, directive and/or approval requirements in which the test activity is included a Electrical Safety tests and measurements on: -Information technology including fice -Electrical for measurement, control and laboratory use -Electrical machines -Medical electrical -Household and similar electrical appliances -Luminaries -Audio, video and similar electrical appliances Activity documents: 1039, 1051, 1029, 1022, 1047, 1031, 1035, 1020, 1043, 1033, 1045, 1027, 1037, 1041, 1024, 1414, 1584, 1614, 1821 as far as relevant in the following documents EN-IEC EN-IEC , 2-010, 2-030, 2-040, EN-IEC EN-IEC , 2-1, 2-5, 2-10, 2-22, 2-24, 2-25, 2-26, 2-27, 2-38, 2-40, 2-47 EN-IEC , 2-6, 2-8, 2-9, 2-13, 2-15, 2-21, 2-23, 2-24, 2-27, 2-29, 2-30, 2-31, 2-32, 2-35, 2-40, 2-44, 2-53, 2-60, 2-65, 2-66, 2-75, 2-80, 2-82, 2-88, 2-97 EN-IEC , 2-1, 2-3, 2-4, 2-7 EN-IEC EN-IEC EN-IEC , EN-IEC , EN-IEC , EN-IEC Dutch Accreditation Council RvA Page 8 8
This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
Location(s) where activities are performed under accreditation Head Office Vijzelmolenlaan 5 & 7 3447 GX oerden The Netherlands Location Abbreviation/ location code Vijzelmolenlaan 5 & 7 3447 GX oerden
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Trafalgar House Trafalgar Close Chandlers Ford Eastleigh SO53 4BW Contact: Mr R P St John James Tel: +44 (0)23 8027 1111 Fax: +44 (0)23 8027 1144 E-Mail: rob@hursley-emc.co.uk Website: www.emctesting.co.uk
More informationNational Voluntary Laboratory Accreditation Program
National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Global Testing Laboratories 3029 E. Gov. John Sevier Hwy. Knoxville, TN 37914-6424 Mr. Craig Baker Phone:
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL TECHNICAL SYSTEMS (NTS) Plano Division 1701 E Plano Pkwy Suite 150 Plano, Texas 75074 Chelsie Morrow Phone: 972 509 2566 Extension 165 Chelsie.Morrow@ntscorp.com
More informationOverview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University
Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
Location(s) where activities are performed under accreditation Head ffice Vijzelmolenlaan 7 3447 GX oerden The Netherlands Location Abbreviation/ location Vijzelmolenlaan 7 3447 GX oerden The Netherlands
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Trafalgar House Trafalgar Close Chandlers Ford Eastleigh SO53 4BW Contact: Mr R P St John James Tel: +44 (0)23 8027 1111 Fax: +44 (0)23 8027 1144 E-Mail: rob@hursley-emc.co.uk Website: www.hursley-emc.co.uk
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
Normative document: EN IS/IEC 17025:2005 Location(s) where activities are performed under accreditation Head ffice Vijzelmolenlaan 7 3447 GX oerden The Netherlands Location Abbreviation/ location Vijzelmolenlaan
More informationLaboratory Accreditation Programmes
Laboratory Address PO Box 68307, Newton, Auckland, 1145 47 Mackelvie Street, Grey Lynn, Auckland, 1021 Telephone 09 360-0862 Fax 09 360-0861 URL Authorised Representative Client No. 2218 Programme Accreditation
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Caddsdown Industrial Estate Clovelly Road Bideford Devon EX39 3DX Contact: Becky Scott Tel: +44 (0)1237 423388 Fax: +44 (0)1237 423434 E-Mail:
More informationHI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date
Last Amended on - Page 1 of 14 I. AUDIO EQUIPMENT 1. Audio-Video and Similar Electronics Apparatus Safety Requirement Marking & Instructions Laser Radiation (Products Marked Class I only) Heating under
More informationSAMSUNG ELECTRO-MECHANICS CO., LTD
Model Name : Features : ㅡ Suitable for LED lighting application ㅡ UL8750, UL1310 Class 2 ㅡ For use in Dry and Damp Location ㅡ Full-protection provided: OCP/OVP/OTP/SCP ㅡ 0-10V Dimming Control ㅡ IP67 ㅡ
More informationEMC Seminar Series All about EMC Testing and Measurement Seminar 1
EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Introduction to EMC Conducted Immunity Jeffrey Tsang Organized by : Department of Electronic Engineering 1 Basic Immunity Standards: IEC
More informationNational Voluntary Laboratory Accreditation Program
National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 VPI Laboratories, Inc. 313 W 12800 S STE 311 Draper, UT 84020 Jason Stewart Phone: 801-495-2310 Email: jasons@vpimfg.com
More informationA Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.
A Comparison Between MIL-STD and Commercial EMC Requirements Part 2 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC immunity
More informationGeneral Safety/EMC and Electrical Information for i-limb ultra and i-limb digits
1. General Safety 1.1 The i-limb ultra and i-limb digits devices are electrical devices, which under certain circumstances could present an electrical shock hazard to the user. Please read the accompanying
More informationSAMSUNG ELECTRO-MECHANICS CO., LTD
Model Name : Features : ㅡ UL8750 / UL1310 Class 2 and CE Class Ⅱ ㅡ Full-protection provided: OCP/OVP/OTP/SCP ㅡ Meets safety requirements for lighting ㅡ Constant Voltage Type ㅡ 5 years warranty ㅡ IP67 Grade
More informationHEC-70LCN-350TDAF Rev B
A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Up to 0.96). Isolation Class II. All-Round Protection: OVP/SCP/OPP Fully isolated metal case with IP20 and dry location. Class 2
More informationHEC-30/35LTA-33TDAA Rev A
A. Features High Efficiency (Up to 86%). Active Power Factor Correction (Typical 0.95). Isolation Class II All-Round Protection: OVP/SCP/OTP/OPP. Fully isolated metal case with IP20 and dry location. 1-10V,
More informationHEC-45LTN-45PFAS Rev A
A. Features High Efficiency (Up to 85%). Active Power Factor Correction (Typical 0.96). Isolation Class II. All-Round Protection: OVP/SCP/OPP. Fully isolated plastic case with IP20 and dry location. Class
More informationEN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass
Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz
More informationPowered Traction Unit OPERATION MANUAL
Powered Traction Unit OPERATION MANUAL CONTENTS Symbols Safety precautions Symbol for CAUTION Symbol for CONSULT INSTRUCTIONS FOR USE Symbol for SERIAL NUMBER Symbol for CATALOGUE NUMBER Symbol for AUTHORISED
More informationBIODEX MULTI- JOINT SYSTEM
BIODEX MULTI- JOINT SYSTEM CONFORMANCE TO STANDARDS 850-000, 840-000, 852-000 FN: 18-139 5/18 Contact information Manufactured by: Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New York, 11967-4704
More informationGuidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System
Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi TS ii ortable Tourniquet System Guidance and manufacturer s declaration electromagnetic emissions The TS ii ortable Tourniquet
More informationElectromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)
Compressor set Equipment Under Test (EUT) Type 028 Type 047 Type 052 Type 085 Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN 60601-1-2:2007 (IEC 60601-1-2:2007) 2017 PARI
More informationHeRO duet
HeRO duet CUSTOMER SERVICE TABLE OF CONTENTS TABLE OF CONTENTS OVERVIEW OVERVIEW OVERVIEW OVERVIEW USING HeRO duet USING HeRO duet USING HeRO duet Current HeRO Score HeRO USING HeRO duet USING HeRO duet
More informationEnglish
English Specifications Type Power Source Vibration Frequency Maximum Output Power Consumption Water Pressure Lighting NE134 AC120V 50/60Hz AC230V 50/60Hz 28~32kHz 8W Max. 42VA 0.1~0.5MPa (1~5kgf/cm
More informationHarmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass
Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,
More informationDiscontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz
Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More information2620 Modular Measurement and Control System
European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic
More informationNational Voluntary Laboratory Accreditation Program
National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Compatible Electronics, Inc. 114 Olinda Drive Brea, CA 92823 Mr. Jeff Klinger Phone: 714-579-0500 Fax: 714-579-1850
More informationHEC-35LTA-XXTSAA Rev A
A. Features High Efficiency (Up to 87%). Active Power Factor Correction (Typical 0.95). Isolation Class II. All-Round Protection: OVP/SCP/OTP/OPP. Fully isolated plastic case with IP20 and dry location.
More informationTEST REPORT... 1 CONTENT...
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2
More informationNational Voluntary Laboratory Accreditation Program
National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Element Materials Technology Elbridge 4939 Jordan Road Elbridge, NY 13060 Mrs. Vicki Albertson Phone: 503-844-4066
More informationEN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A
Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that UltraTech Engineering Labs Inc. 3000 Bristol
More informationEMC Test report for LED Panel Light Models , , , , ,
4326247.50 EMC Test report for LED Panel Light Models 000529, 000530, 000531, 000532, 000535, 000536 Guangzhou, date of issue: 2016-02-24 Author:Jazz Liang By order of Marvo Verlichting B.V. at Hoogeveen,
More informationIntroduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.
Introduction to EMC Schurter has over 75 years experience in the electronics and electrical industries, developing and manufacturing components that ensure a clean and safe supply of power. Schurter provides
More informationAccr. 002-Test EN-ISO (2005)
Electromagnetic compatibility LAB > Examination of compliance with EMC standards > Measurement of radio-disturbances > Immunity tests > 2004/108/EC EMC Directive > CE Marking > Measurement of electromagnetic
More informationBy order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China
4317137.50 EMC Test report for LED Fixed luminaires Models LED12036-1R, LED12036-2TU, LED120363R, LED12036-4TU2, LED12036-6TR, LED12036-1R CHR, LED12036-2TU CHR, LED12036-3R CHR, LED12036-4TU2 CHR, LED12036-6TR
More informationEUROPEAN ETS TELECOMMUNICATION November 1997 STANDARD
EUROPEAN ETS 300 826 TELECOMMUNICATION November 1997 STANDARD Source: ERM Reference: DE/ERM-EMC-014 ICS: 33.020 Key words: Broadband, data, EMC, HIPERLAN, radio, system, testing, transmission Electromagnetic
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TIMCO ENGINEERING, INC. 849 NW State Road 45 Newberry, FL 32669 Sid Sanders - Phone: 352 472 5500 E-mail: sid@timco.cc Website: http://www.timcoengr.com ELECTRICAL
More informationRE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal
More informationRE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal
More informationAn Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF
An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF Definition of ElectroMagnetic Compatibility (EMC) EMC is defined as: "The ability of devices and
More informationEN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd
Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE
More informationTEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed
17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:
More informationElectromagnetic Compatibility
Electromagnetic Compatibility Introduction to EMC International Standards Measurement Setups Emissions Applications for Switch-Mode Power Supplies Filters 1 What is EMC? A system is electromagnetic compatible
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TIMCO ENGINEERING, INC. 849 NW State Road 45 Newberry, FL 32669 Sid Sanders - Phone: 352 472 5500 E-mail: sid@timco.cc Website: http://www.timcoengr.com ELECTRICAL
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 QAI LABORATORIES LTD. 1 3980 North Fraser Way Burnaby, British Columbia, Canada, V5J 5K5 Contact: Parminder Singh Phone: 604-527-8378 ELECTRICAL Valid to: October
More informationC series Product brief
Product brief Key applications Landlord sub-metering Object metering Meter performance Direct connected up to 0 ctive energy Low power consumption larm function Pulse output Installation Small size - 1
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-12024-06-02 according to DIN EN ISO/IEC 17025:2005 Period of validity: 02.06.2017 to 01.06.2022 Holder of certificate: Bureau
More informationEMC Requirement for LED Lighting and Accessories & EMC Facilities in SIRIM
EMC Requirement for LED Lighting and Accessories & EMC Facilities in SIRIM By: Azizul Azman Jaafar Sr. Testing Executive RF&EMCT Section Testing Services Department RFEMCT SECTION ORGANIZATION CHART HEAD
More informationNational Voluntary Laboratory Accreditation Program
National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Compatible Electronics, Inc. 20621 Pascal Way Lake Forest/Silverado, CA 92630 Mr. Jeff Klinger Phone: 949-587-0400
More informationAS/NZS CISPR 14.2:2015
AS/NZS CISPR 14.2:2015 (CISPR 14-2, Ed. 2.0:2015, IDT) Australian/New Zealand Standard Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 2:
More informationTest and Measurement for EMC
Test and Measurement for EMC Bogdan Adamczyk, Ph.D., in.c.e. Professor of Engineering Director of the Electromagnetic Compatibility Center Grand Valley State University, Michigan, USA Ottawa, Canada July
More informationHEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications
HEC130/150RTN48QSCA A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Typical 0.96). Isolation Class I (With FG) AllRound Protection: OVP/SCP/OTP/OPP. Fully isolated Metal case with
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25
15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE
More informationTechnical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.
Technical Data Electrocardiograph ECG-1250K This technical data may be revised or replaced by Nihon Kohden at any time without notice. TD.ECG1250_L Specifications ECG input Input impedance: 20 MΩ Electrode
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27
15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE
More informationEMC standards. Presented by: Karim Loukil & Kaïs Siala
Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards
More informationAmerican National Standard for Methods of Measurement. Frequency allocations and radio treaty matters; general rules and regulations
IAS Accreditation Number Company Name Address TL-637 UL Korea, LTD Suwon Laboratory 218 Maeyeong-Ro, Yeongtong-Gu Suwon-Si, Gyeonggi-Do 16675 Republic of Korea Mr. YongJin Suk, Laboratory Manager Contact
More informationFeatures. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter
Features Regulated Converters Description Compact low profile AC-DC power supply mw no load power consumption Class II power supply with kvac isolation Universal input voltage range (~VAC) Low output ripple/noise
More informationBulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results
Immunity Testing: radiated immunity 41 Bulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results Immunity Testing: radiated immunity 42 Bulk Current
More informationProduct Specification sheet
INPUT MINIMUM RATED MAXIMUM Input Voltage 90V AC 100 240V AC 264V AC Input Frequency 47 Hz 50 / 60 Hz 63 Hz Input Current * 350mA Inrush Current **
More informationImmunity Testing for the CE Mark
Immunity Testing for the CE Mark Summary The European Union (EU) currently has 25 member countries with 2 additional countries to be added in 2007. The total population at that time will be nearly a half
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 DEKRA TESTING AND CERTIFICATION (SUZHOU) CO., LTD. No. 99 Hongye Rd., Suzhou Industrial Park Suzhou, Jiangsu Province, 215006 People s Republic of China Mr.
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. MiCOM LABS 1, Boulder Court Pleasanton, California USA Gordon Hurst Phone: (+1)
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MiCOM LABS 1, 2 575 Boulder Court Pleasanton, California 94566 USA Gordon Hurst Phone: (+1) 925 462 0304 ELECTRICAL (EMC) Valid to: May 31, 2018 Certificate
More information2015 / 9C EN-00 OSRAM GmbH Marcel-Breuer-Str München Germany. Radio and Telecommunications Terminal Equipment
OSRAM OSRAM Manufacturer or representative: Address: 2015 / 9C1-3271666-EN-00 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany Brand name or trade mark: Product type: Product designation: OSRAM Radio
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Variant Model Name: Applicant: CAMERA HOUSING SAMSUNG TECHWIN CO., LTD. SCX-FH200B SHB-4200 SAMSUNG TECHWIN
More informationFS24W Series LED Driver Input: V High Power Factor High efficiency Subminiaturization IP66 SPECIFICATIONS
SPECIFICATIONS Product Features: Input voltage Range:100~277VAC; Power Factor up to 0.99; Efficiency up to 88%; PSR topology, high reliability; Meet UL8750 UL1310 CB CE; International Protection:IP66;
More informationCE Testing Results and Explanation
1500 West University Parkway Sarasota, Florida 34243 Phone 941-362-1200 Telefax 941-362-1290 www.sunhydraulics.com CE Testing Results and Explanation This article summarizes the electromagnetic compatibility
More informationTest Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller
Test Report Applicant: Product Name: Brand Name: Model No.: Apricus Solar Co., Ltd. Multi-Function Differential Controller Apricus MFC-1 Date of Receipt : Jan. 04, 2012 Date of Test: Jan. 04, 2012 Date
More informationHEC-40LTN-XXPSCA Rev A
HEC40LTNXXPSCA Rev A A. Features High Efficiency (Up to 89%). Active Power Factor Correction (Typical 0.95). Isolation Class II AllRound Protection: OVP/SCP/OTP/OPP. Fully isolated plastic case with IP67
More informationReport for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B
Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed
More informationRE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Control type [Us] rated supply voltage Voltage range Main Range of product Product or component
More informationR&TTE Testing For EU Market
R&TTE Testing For EU Market Derek Y W Leung IEEE Hong Kong EMC Chapter Committee Member 1 R&TTE Directive 1999/5/EC Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on
More information1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2
INDEX PAGE 1. Electro-Static Discharge Test EN61000-4-2.. R-1 2. Radiated Susceptibility Test EN61000-4-3 R-2 3. Electrical Fast Transient Burst Test EN61000-4-4 R-3 4. Surge Test EN61000-4-5 R-4 5. Conducted
More informationOne-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems
One-day Conference 18 March 2017 Power Supply, EMC and Signalling, in Railway Systems EMC Management and Related Technical Aspects in Railway Systems By Dr Peter S W LEUNG http://www.ee.cityu.edu.hk/~pswleung/
More informationFeatures. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.
Features Regulated Converters Description Long 5 Year Warranty 2MOPP/250VAC Suitable for built in Class II Applications Wide Input Voltage Range (85-264VAC) Low Leakage Current (
More informationTEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated
Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances, electric tools
More informationRE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC
Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay
More informationRE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC
Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay
More informationHEC-100RTA-48QSCA Rev A1.0
HEC100RTA48QSCA Rev A1.0 A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Typical 0.96). Isolation Class I (With FG) AllRound Protection: OVP/SCP/OTP/OPP. Fully isolated Metal case
More informationEMC & Electrical Test Laboratory EMC LAB EQUIPMENT RESOURCES PER OEM TEST METHOD EQUIPMENT DCX FORD GM
EMC & Electrical Laboratory Page 1 of 5 Purpose: To maintain a list of equipment resources required per OEM test method. Responsibility: EMC technical manager, EMC lab technicians Method: EQUIPMENT DCX
More informationEUROPEAN pr ETS TELECOMMUNICATION January 1997 STANDARD
DRAFT EUROPEAN pr ETS 300 329 TELECOMMUNICATION January 1997 STANDARD Second Edition Source: ETSI TC-RES Reference: RE/RES-09036 ICS: 33.020 Key words: DECT, EMC, radio, testing Radio Equipment and Systems
More informationNursing Beds with Dewert drive system
Nursing Beds with Dewert drive system GB Casa Med Classic 4 / Classic (FS) Casa Med Ultra / Ultra (FS) Casa Med Classic Low Casa Med Classic (FS) 4 / Classic / Casa FS Med / Casa Classic Med Low Ultra
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-12067-01-02 according to DIN EN ISO/IEC 17025:2005 Period of validity: 20.05.2016 to 19.05.2021 Holder of certificate: EMCCons
More informationEMC Test Report. Report Number: M030826
Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report
More informationEMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS
EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by
More informationTechnical Specifications Micromedical VisualEyes 505 by Interacoustics
VisualEyes 505 - Technical Specifications Page 0 Technical Specifications Micromedical VisualEyes 505 by Interacoustics D-0115523-B 2018/02 VisualEyes 505 - Technical Specifications Page 1 Included and
More informationKutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger
Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 ISERT (Pty) Ltd. Reg: 2017/186396/07 Tel: + 27 (0)12 548 0940 E-Mail: info@isert.co.za 129 Khai-Apple street Montana Pretoria 0186 EMC TEST
More informationTest Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49
Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 The following information was submitted and identified by/on behalf of the client as: Applicant : Ningbo Shanhuang Electric Appliance
More informationEN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments
EMC Page 3 / 33 Test report No.: EN 61000-6-3:2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: 2013-10-16
More informationTest Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013
More informationSERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
International Telecommunication Union ITU-T L.1005 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (02/2014) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE
More informationEMC LAB EQUIPMENT CALIBRATION SCHEDULER
Page 1 of 7 Purpose: To maintain a list of equipment scheduled for calibration and the test methods where is involved. Responsibility: Technical manager, EMC lab technicians Overview: The actual calibration
More informationFeatures. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter
Features Regulated Converter Unique, patent-pending design Isolated power supply with integrated mains filter Packaged inside of line filter case Safe, touchable DC outputs Easy installation Worldwide
More informationDiscontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz
Reference No.: WTU15U0933879E Page 2 of 45 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More information1 SUMMARY OF STANDARDS AND RESULTS
1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: EMISSION Description of Test Item Standard
More information