This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation"

Transcription

1 Annex to declaration accreditation (scope accreditation) Locations where activities are performed under accreditation Location Abbreviation/ location code Head Location Vijzelmolenlaan 5 & GX oerden The Netherlands On-site O Electromagnetic Compatibility (EMC): Automotive emission measurements 1 Electrical/ sub-assembly Conducted Emissions, Voltage method (AN) 150 khz to 108 MHz document 877 CISPR 25 Ford FMC1278, section CE420 Ford EMC-CS-2009, section CE420 GM Conducted Emissions, Current method (Current Probe) 150 khz to 108 MHz 3 Radiated Emissions, Anechoic Chamber method 150 khz to 2,5 GHz 4 Motor vehicles Radiated Emissions, Semi Anechoic Chamber method 30 MHz to 1000 MHz document 879 CISPR 25 document 887 CISPR 25 97/24/EC, chapter 8, Annex V and VI ECE Regulation 10, Annex 7 and 8 Ford FMC1278, section RE310 Ford EMC-CS-2009, section RE310 GM3097 document 885 CISPR 12 97/24/EC, chapter 8, Annex II and III ECE Regulation 10, Annex 4 and 5 This annex has been approved by the Board the Dutch Accreditation Council, on its behalf, J.A..M. de Haas Director Operations Dutch Accreditation Council RvA Page 1 8

2 Annex to declaration accreditation (scope accreditation) Electromagnetic Compatibility (EMC): Automotive immunity tests 5 Electrical/ subassembly Radiated Immunity, Anechoic Chamber method 200 MHz to 4 GHz up to 200 V/m 1,2 to 1,4 GHz and 2,7 to 3,1 GHz up to 300 V/m document 891 ISO /24/EC, chapter 8, Annex VII ECE Regulation 10, Annex 9 Ford FMC1278, section RI114 Ford EMC-CS-2009, section RI114 (radar limited to 300 V/m) GM3097 (radar limited to 300 V/m) 6 Bulk Current Injection method 100 khz to 1 MHz, up to 150 ma 1 to 400 MHz, up to 300 ma 7 Electro Static Discharge immunity (ESD) Contact discharge: kv Air discharge: kv 8 Electrical transient conduction along supply lines only 9 Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines 10 Motor vehicles Radiated Immunity, Semi Anechoic Chamber method 20 MHz to 80 MHz up to 30 V/m 80 MHz to 4 GHz up to 50 V/m document 875 ISO /24/EC, chapter 8, Annex VII ECE Regulation 10, Annex 9 Ford FMC1278, section RI112 Ford EMC-CS-2009, section RI112 GM3097 document 881/1790 ISO Ford FMC1278, section CI280 Ford EMC-CS-2009, section CI280 GM3097 document 882, 883 ISO ECE Regulation 10, Annex 10 document 884 ISO document 889 ISO /24/EC, Chapter 8, Annex IV ECE Regulation 10, Annex 6 Dutch Accreditation Council RvA Page 2 8

3 Annex to declaration accreditation (scope accreditation) Electromagnetic Compatibility (EMC): Emission measurements 11 Electric- and Conducted Emissions, Voltage method (AMN) 9 khz to 30 MHz document 850 EN , CISPR 14-1 EN 55015, CISPR 15 EN 55022, CISPR Conducted Emissions, Voltage method (AAN) 150 khz to 30 MHz 13 Conducted Emissions, Voltage method (Voltage probe) 150 khz to 30 MHz 14 Conducted Emissions, Current method (Current probe) 150 khz to 30 MHz 15 Conducted Emissions, Disturbance power method (Absorber clamp) 30 MHz to 300 MHz 16 Radiated Emissions, Open Area Test Site / Semi Anechoic Chamber method, 9 KHz to 1GHz 17 Radiated Emissions, Full Anechoic Chamber method 30 MHz to 8GHz 18 Radiated Emissions, Loop Antenna System (LAS) method 9 khz to 30 MHz document 1796 EN 55022, CISPR 22, EN 55032, CISPR 32 document 852 EN , CISPR 14-1 EN 55015, CISPR 15 document 848 EN 55022, CISPR 22 document 854 EN EN , CISPR 14-1 document 841/868 EN EN 55022, CISPR 22 document 864 EN EN 55022, CISPR 22 document 866 EN EN 55015, CISPR 15 Dutch Accreditation Council RvA Page 3 8

4 Annex to declaration accreditation (scope accreditation) 19 Electric- and Harmonic Current Emissions 0 Hz to 2 khz document 862 EN-IEC Voltage Fluctuations and Flicker document 860 EN-IEC Electromagnetic Compatibility (EMC): Immunity tests 21 Electric- and Electro Static Discharge immunity (ESD) Contact discharge: kv Air discharge: kv document 859 EN-IEC Radiated electromagnetic field immunity, Anechoic Chamber method 26 MHz to 80 MHz: 3 V/m 80 MHz to 4 GHz: 30 V/m 4 GHz to 6 GHz: 10 V/m 23 Electrical Fast Transient/burst (EFT) immunity document 872 EN-IEC document 858 EN-IEC Surge immunity document 874 EN-IEC Immunity to conducted disturbances 150 khz to 230 MHz 30 Vrms document 856 EN-IEC Power frequency magnetic field immunity document 1829 EN-IEC Voltage dips, short interruptions and voltage variations immunity 50 Hz document 1852 EN-IEC Temperature and Humidity tests 28 Electrical s,, components and installations Cold test type Ab and Ad Time: Up to 200 hours Temp: -25 up to +5 C Humidity: 0% (up to 0 C) 50% above 0 C EN-IEC Dry heat test type Bb and Bd Time: Up to 200 hours Temp: +25 up to +160 C Humidity: 20-50% EN-IEC Dutch Accreditation Council RvA Page 4 8

5 Annex to declaration accreditation (scope accreditation) 30 Electrical s,, components and installations Damp heat cycle Time: Up to 200 hours Temp: +25/+55 C Humidity: 90-98% EN-IEC Composite T/H cycle Time: Up to 300 hours Temp: -10 up to +65 C Humidity: 50-98% 32 Damp heat type Ca and Cb. Time: Up to 200 hours Temp:+25 up to +45 C Humidity: 80-98% EN-IEC EN-IEC Electrical Safety tests and measurements 33 Electrical s, Input power measurement document 1039 & O 34, components and installations Creepage and clearance measurement document 1029 & O EN-IEC Distance through insulation measurement document 1022 & O 36 Stability measurement document 1047 & O 37 Mechanical strength housing tests: Vertical (steel ball) & spring hammer tests (IK2 IK9) Free Fall tests Push / force tests document 1031 EN-IEC , EN-IEC , EN-IEC 62262, EN-IEC60065: cl , , 9.1.7, 12.4, EN-IEC 60335: cl , EN-IEC 60598: cl , EN-IEC 60601: 5.9.2, , , EN-IEC 60950: cl , 4.2.2, 4.2.3, 4.2.4, 4.2.6, EN-IEC 61010: cl , 8.2, 8.3 & O 38 (Earth) Leakage current measurement document 1035 EN-IEC & O 39 Abnormal operation and single fault conditions document 1020 & O Dutch Accreditation Council RvA Page 5 8

6 Annex to declaration accreditation (scope accreditation) 40 Electrical s,, components and installations Capacitance discharge / residual voltage measurement document 1043 & O 41 Earth resistance measurement document 1033 & O 42 Reverse current lithium battery measurement document 1045 EN-IEC & O 43 Dielectric and electric strength test document 1027 EN-IEC , EN , EN & O 44 Insulation resistance test document 1037 & O 45 Temperature test document Degree protection provided by enclosures (IP) IPx3, IPx4, IPx5 IP0x, IPx0, IP1x, IP2x, IP3x, IP4x document 1024 EN-IEC Durability and legibility labeling test document 1414 & O 48 Household appliances and similar apparatus Measurement methods electromagnetic fields with regard to human exposure document 1543 EN-IEC & O 49 Medical Electrical Equipment Defibrillation pro applied parts: - Defibrillation protection (common mode and differential mode) - Energy reduction test document 1821 EN-IEC :2006 +A1:2013, cl EN-IEC :2014, cl EN-IEC :2015, cl ECG functional tests (essential performance / protection against hazardous output) document 1584 EN-IEC :2015, cl EN-IEC :2014, cl EN-IEC :2015, cl Dutch Accreditation Council RvA Page 6 8

7 Annex to declaration accreditation (scope accreditation) Electromagnetic Compatibility (EMC): FCC emission measurements 51 Electric- and, unintentional radiators Conducted Emissions, Voltage method (AMN) 10 khz to 30 MHz 52 Radiated Emissions, Open Area Test Site / Semi Anechoic Chamber method 30 MHz to 8 GHz document 911 ANSI C63.4 FCC MP-5 47 CFR 15, 47 CFR 18 document 913/1129 ANSI C63.4 FCC MP-5 47 CFR 15, 47 CFR 18 Electromagnetic Compatibility (EMC): Emission measurements on-site 53 Electric- and Conducted Emissions, Voltage method (LISN AMN) 150 khz to 30 MHz document 899 & O 54 Conducted Emissions, Voltage method (Voltage probe) 150 khz to 30 MHz 55 Radiated Emissions, 30 MHz to 1GHz document 901 document 907 EN , CISPR & O & O Electromagnetic Compatibility (EMC): Immunity tests on-site 56 Electric- and Electro Static Discharge immunity (ESD) Contact discharge: kv Air discharge: kv document 906 EN-IEC & O 57 Radiated electromagnetic field immunity, 80 MHz to 1 GHz: 10 V/m 58 Electrical Fast Transient/burst (EFT) immunity up to + 4 kv 59 Immunity to conducted disturbances 150 khz to 80 MHz 10 Vrms document 909 In-house method document 905 EN-IEC document 903 Equivalent to EN-IEC & O & O & O Dutch Accreditation Council RvA Page 7 8

8 Annex to declaration accreditation (scope accreditation) Item a as given below shows the relation between the test activities as mentioned above and the standards, directive and/or approval requirements in which the test activity is included a Electrical Safety tests and measurements on: -Information technology including fice -Electrical for measurement, control and laboratory use -Electrical machines -Medical electrical -Household and similar electrical appliances -Luminaries -Audio, video and similar electrical appliances Activity documents: 1039, 1051, 1029, 1022, 1047, 1031, 1035, 1020, 1043, 1033, 1045, 1027, 1037, 1041, 1024, 1414, 1584, 1614, 1821 as far as relevant in the following documents EN-IEC EN-IEC , 2-010, 2-030, 2-040, EN-IEC EN-IEC , 2-1, 2-5, 2-10, 2-22, 2-24, 2-25, 2-26, 2-27, 2-38, 2-40, 2-47 EN-IEC , 2-6, 2-8, 2-9, 2-13, 2-15, 2-21, 2-23, 2-24, 2-27, 2-29, 2-30, 2-31, 2-32, 2-35, 2-40, 2-44, 2-53, 2-60, 2-65, 2-66, 2-75, 2-80, 2-82, 2-88, 2-97 EN-IEC , 2-1, 2-3, 2-4, 2-7 EN-IEC EN-IEC EN-IEC , EN-IEC , EN-IEC , EN-IEC Dutch Accreditation Council RvA Page 8 8

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Trafalgar House Trafalgar Close Chandlers Ford Eastleigh SO53 4BW Contact: Mr R P St John James Tel: +44 (0)23 8027 1111 Fax: +44 (0)23 8027 1144 E-Mail: rob@hursley-emc.co.uk Website: www.hursley-emc.co.uk

More information

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

EMC Seminar Series All about EMC Testing and Measurement Seminar 1 EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Introduction to EMC Conducted Immunity Jeffrey Tsang Organized by : Department of Electronic Engineering 1 Basic Immunity Standards: IEC

More information

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc. A Comparison Between MIL-STD and Commercial EMC Requirements Part 2 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC immunity

More information

HEC-30/35LTA-33TDAA Rev A

HEC-30/35LTA-33TDAA Rev A A. Features High Efficiency (Up to 86%). Active Power Factor Correction (Typical 0.95). Isolation Class II All-Round Protection: OVP/SCP/OTP/OPP. Fully isolated metal case with IP20 and dry location. 1-10V,

More information

HEC-70LCN-350TDAF Rev B

HEC-70LCN-350TDAF Rev B A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Up to 0.96). Isolation Class II. All-Round Protection: OVP/SCP/OPP Fully isolated metal case with IP20 and dry location. Class 2

More information

HEC-45LTN-45PFAS Rev A

HEC-45LTN-45PFAS Rev A A. Features High Efficiency (Up to 85%). Active Power Factor Correction (Typical 0.96). Isolation Class II. All-Round Protection: OVP/SCP/OPP. Fully isolated plastic case with IP20 and dry location. Class

More information

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi TS ii ortable Tourniquet System Guidance and manufacturer s declaration electromagnetic emissions The TS ii ortable Tourniquet

More information

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor. Introduction to EMC Schurter has over 75 years experience in the electronics and electrical industries, developing and manufacturing components that ensure a clean and safe supply of power. Schurter provides

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

Accr. 002-Test EN-ISO (2005)

Accr. 002-Test EN-ISO (2005) Electromagnetic compatibility LAB > Examination of compliance with EMC standards > Measurement of radio-disturbances > Immunity tests > 2004/108/EC EMC Directive > CE Marking > Measurement of electromagnetic

More information

EMC Requirement for LED Lighting and Accessories & EMC Facilities in SIRIM

EMC Requirement for LED Lighting and Accessories & EMC Facilities in SIRIM EMC Requirement for LED Lighting and Accessories & EMC Facilities in SIRIM By: Azizul Azman Jaafar Sr. Testing Executive RF&EMCT Section Testing Services Department RFEMCT SECTION ORGANIZATION CHART HEAD

More information

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications HEC130/150RTN48QSCA A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Typical 0.96). Isolation Class I (With FG) AllRound Protection: OVP/SCP/OTP/OPP. Fully isolated Metal case with

More information

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed 17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:

More information

Test and Measurement for EMC

Test and Measurement for EMC Test and Measurement for EMC Bogdan Adamczyk, Ph.D., in.c.e. Professor of Engineering Director of the Electromagnetic Compatibility Center Grand Valley State University, Michigan, USA Ottawa, Canada July

More information

Immunity Testing for the CE Mark

Immunity Testing for the CE Mark Immunity Testing for the CE Mark Summary The European Union (EU) currently has 25 member countries with 2 additional countries to be added in 2007. The total population at that time will be nearly a half

More information

CE Testing Results and Explanation

CE Testing Results and Explanation 1500 West University Parkway Sarasota, Florida 34243 Phone 941-362-1200 Telefax 941-362-1290 www.sunhydraulics.com CE Testing Results and Explanation This article summarizes the electromagnetic compatibility

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-12067-01-02 according to DIN EN ISO/IEC 17025:2005 Period of validity: 20.05.2016 to 19.05.2021 Holder of certificate: EMCCons

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 DEKRA TESTING AND CERTIFICATION (SUZHOU) CO., LTD. No. 99 Hongye Rd., Suzhou Industrial Park Suzhou, Jiangsu Province, 215006 People s Republic of China Mr.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. MiCOM LABS 1, Boulder Court Pleasanton, California USA Gordon Hurst Phone: (+1)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. MiCOM LABS 1, Boulder Court Pleasanton, California USA Gordon Hurst Phone: (+1) SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MiCOM LABS 1, 2 575 Boulder Court Pleasanton, California 94566 USA Gordon Hurst Phone: (+1) 925 462 0304 ELECTRICAL (EMC) Valid to: May 31, 2018 Certificate

More information

FS24W Series LED Driver Input: V High Power Factor High efficiency Subminiaturization IP66 SPECIFICATIONS

FS24W Series LED Driver Input: V High Power Factor High efficiency Subminiaturization IP66 SPECIFICATIONS SPECIFICATIONS Product Features: Input voltage Range:100~277VAC; Power Factor up to 0.99; Efficiency up to 88%; PSR topology, high reliability; Meet UL8750 UL1310 CB CE; International Protection:IP66;

More information

HEC-100RTA-48QSCA Rev A1.0

HEC-100RTA-48QSCA Rev A1.0 HEC100RTA48QSCA Rev A1.0 A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Typical 0.96). Isolation Class I (With FG) AllRound Protection: OVP/SCP/OTP/OPP. Fully isolated Metal case

More information

R&TTE Testing For EU Market

R&TTE Testing For EU Market R&TTE Testing For EU Market Derek Y W Leung IEEE Hong Kong EMC Chapter Committee Member 1 R&TTE Directive 1999/5/EC Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on

More information

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller Test Report Applicant: Product Name: Brand Name: Model No.: Apricus Solar Co., Ltd. Multi-Function Differential Controller Apricus MFC-1 Date of Receipt : Jan. 04, 2012 Date of Test: Jan. 04, 2012 Date

More information

Nursing Beds with Dewert drive system

Nursing Beds with Dewert drive system Nursing Beds with Dewert drive system GB Casa Med Classic 4 / Classic (FS) Casa Med Ultra / Ultra (FS) Casa Med Classic Low Casa Med Classic (FS) 4 / Classic / Casa FS Med / Casa Classic Med Low Ultra

More information

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed

More information

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 The following information was submitted and identified by/on behalf of the client as: Applicant : Ningbo Shanhuang Electric Appliance

More information

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances, electric tools

More information

TE W Single Output External Power Test & Measurement/Industrial Series

TE W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 120W of AC-DC Power Universal Input 90-264Vac Input Range IPX-2 Rated Enclosure for protection against liquid

More information

Fundamentals of EMC Theory and Principles

Fundamentals of EMC Theory and Principles EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Fundamentals of EMC Theory and Principles Dr. LEUNG, Peter Sai Wing 梁世榮 http://www.ee.cityu.edu.hk/~pswleung/ edu hk/ pswleung/ Organized

More information

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan 4322705.50 EMC Test report for Plug-in adaptor Models PM1W-IT, PM1WU2-IT, PM1W-GR, PM1W-SP, PM1W-RS, PM1WB-RS, PM1WU2-GR, PM1WU2-SP, PM1WU2-RS, PM1WBU2-RS, PM1W-UK, PM1WU2-UK, PM1W-FR, PM1WU2-FR Guangzhou,

More information

Ackrediteringens omfattning/scope of accreditation

Ackrediteringens omfattning/scope of accreditation Bilaga/Anne 2G EMC GENERIC STANDARDS European std International std Title Fleible scope EN 61000-6-1:2007 IEC 61000-6-1:2005 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity

More information

TE90 90W Single Output External Power Test & Measurement/Industrial Series

TE90 90W Single Output External Power Test & Measurement/Industrial Series Features Meets U.S. DoE Efficiency Level VI and EU CoC Tier 2 Requirements No load input power Average Efficiency Up to 90W of AC-DC Power Universal Input 90-264Vac Input Range IP22 Rated Enclosure Meets

More information

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter Page 1 of 48 EMC TEST REPORT for Coliy Technology Co.,Ltd. Fluxgate Gaussmeter Prepared for : Coliy Technology Co.,Ltd. Address : Block B,9 th Floor,Xinzhongtai Business Building,Gushu 2nd Road,Xi Town,Bao

More information

EMC TEST REPORT For Prokits Industries Co., Ltd.

EMC TEST REPORT For Prokits Industries Co., Ltd. Page 1 of 34 EMC TEST REPORT For Prokits Industries Co., Ltd. Temperature-Controlled Soldering Station Model No.:SS-206/207 Series Test Report Number : ESTSZ110701228E EST COMPLIANCE LABORATORY LIMITED

More information

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference Electromagnetic Compatibility and Electrical Safety GR-1089-CORE Table of Contents Table of Contents 1 Introduction 1.1 Purpose and Scope.................................. 1 1 1.2 Items Not Covered in

More information

ANSI-ASQ National Accreditation Board/ACLASS

ANSI-ASQ National Accreditation Board/ACLASS ANSI-ASQ National Accreditation Board/ACLASS SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Advanced Compliance Solutions, Inc. 3998 Fau Blvd., Suite 310, Boca Raton, FL 33431 Randy Abernathy, Quality Manager,

More information

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer

More information

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI and EU CoC Tier 2 Requirements No load input power Average Efficiency Up to 60W of AC-DC Power Universal Input 90-264Vac Input Range Meets Heavy Industrial Levels

More information

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features LPS Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 20W of AC-DC Power Universal Input 90-264Vac Input Range Desktop and Wall-Plug versions Meets Heavy

More information

EMC TEST REPORT Model: 053-EMC-TR_ING, rev. 12 del 15/05/08. Laboratory identification: L.E.M. S.r.l. UNI CEI EN ISO/IEC EMC Laboratory

EMC TEST REPORT Model: 053-EMC-TR_ING, rev. 12 del 15/05/08. Laboratory identification: L.E.M. S.r.l. UNI CEI EN ISO/IEC EMC Laboratory L.E.M. S.r.l. Notified Body (ID 2034) EMC TEST REPORT Model: 053-EMC-TR_ING, rev. 12 del 15/05/08 Laboratory identification: L.E.M. S.r.l. UNI CEI EN ISO/IEC 17025 EMC Laboratory recognized by Ministry

More information

9. Electrostatic Discharge Immunity Test (ESD)

9. Electrostatic Discharge Immunity Test (ESD) 9. Electrostatic Discharge Immunity Test (ESD) Test Mode: Mode 1 Final Test Result : PASS Pass Performance Criteria : A Required Performance Criteria: B Basic Standard : IEC 61000-4-2:Edition 1.2:2001-04

More information

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests Harmonizing the ANSI-C12.1(2008) EMC Tests Subcommittee 1 (Emissions) Subcommittee 5 (Immunity) Joint Task Force on C12.1 June 17, 2013 1 The Accredited Standards Committee C63 presents Harmonizing the

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS CISPR 11:2011 IEC CISPR 11, Ed. 5.1 (2010) AS/NZS CISPR 11:2011 Australian/New Zealand Standard Industrial, scientific and medical equipment Radio-frequency disturbance characteristics Limits and

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT MATERIALS TECHNOLOGY MINNEAPOLIS LLC (A subsidiary of Element Materials Technology Minneapolis Inc.) 9725 Girard Avenue South Minneapolis, MN 55431

More information

CP-T range Product group picture

CP-T range Product group picture Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details

More information

(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual

(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual Edition 1 Notice i-pad Operator s Manual CU Medical Systems, Inc. reserves the right to make changes on the device specifications contained in this manual at any time without prior notice or obligation

More information

MB120S 120W Single Output Medical Series

MB120S 120W Single Output Medical Series Features 2 x 4 x 1.25 Package, Ideal for 1U Applications 10-year Life design with Premium E-Caps 100 Watts convection cooled Class B Conducted and Radiated EMI performance BF Isolation Type Rated Designed

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 75.00 USD Main Range of product Product

More information

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter Features Regulated Converter Description Wide input range 85-35Vac Full load temperature range: -4 C to +65 C Ultra-high efficiency over entire load range No external components necessary International

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

AS/NZS CISPR 14.1:2013

AS/NZS CISPR 14.1:2013 AS/NZS CISPR 14.1:2013 CISPR 14-1, Ed.5.2 2011, IDT Australian/New Zealand Standard Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 1: Emission

More information

Conducted emission pre compliance measurements

Conducted emission pre compliance measurements V1.1 Conducted emission pre compliance measurements All electronic products need to be tested for electromagnetic emissions that may negatively effect the correct operation of other equipment nearby. Electromagnetic

More information

AP7301 ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY L T P C COURSE OBJECTIVES:

AP7301 ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY L T P C COURSE OBJECTIVES: AP7301 ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY L T P C 3 0 0 3 COURSE OBJECTIVES: To understand the basics of EMI To study EMI Sources To understand EMI problems To understand Solution methods in

More information

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-89486194-805 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances,

More information

CP-T range Benefits and advantages

CP-T range Benefits and advantages Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers

More information

TEST REPORT. Report Number: DAL-001 Project Number: G Report Issue Date: February 6, 2013

TEST REPORT. Report Number: DAL-001 Project Number: G Report Issue Date: February 6, 2013 TEST REPORT Report Number: 100943193DAL-001 Project Number: G100943193 Report Issue Date: February 6, 2013 Product Designation: Standards: Vibrating Fork Level Switch Model: RS85 CENELEC EN 61326-1*BEI

More information

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

Test Report. Ningbo Goldmore Industrial Co.,Ltd. Test Report Applicant: Ningbo Goldmore Industrial Co.,Ltd. Product Name: Brand Name: Model No.: LED CAMPING LANTERN with FAN N/A XJH-8098 Date of Receipt : Sep. 23, 2014 Date of Test: Sep. 25, 2014 Date

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC Fulton Place Fremont, CA Steve Behm Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC Fulton Place Fremont, CA Steve Behm Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CKC LABORATORIES, INC. 1120 Fulton Place Fremont, CA 94539 Steve Behm Phone: 209 966 5240 ELECTRICAL (EMC) Valid to: March 31, 2019 Certificate Number: 0803.06

More information

VN415/VO425 Specifications

VN415/VO425 Specifications VN415/VO425 Specifications Item No. 8105231-1 01/2014 Contents VN415 Specifications... 1 1.1 Technical Standards:...1 1.2 System Requirements:...1 1.3 Included and Optional Parts...2 VO425 Specifications...

More information

Industrial Applications Telecom Daracom

Industrial Applications Telecom Daracom ABC200 Series is a family of compact and efficient AC-DC power supplies suited for telecom datacom and many other industrial applications. This family meets the international information technology safety

More information

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter Features Regulated Converter Description 5W Class II power supply in compact 1 x 1 Package (high power density) Internal EMC class B filter UL/IEC/EN695-1 certified UL/IEC/EN62368-1 certified Electrical

More information

CE TEST CERTIFICATION

CE TEST CERTIFICATION according to Certification No.: E5NC004 European Standard EN 61000-6-4:2001 EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 61000-6-2:2001 ( IEC 61000-4-2:1995/A1:1998, IEC 61000-4-3: 1995/A1:1998,

More information

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 11 to 15 April EMC standards

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 11 to 15 April EMC standards Training Course on Conformity and Interoperability, Tunis-Tunisia, from 11 to 15 April 2016 EMC standards Presented by: Karim Loukil & Kaïs Siala Karim.wakil@cert.mincom.tn Kais.siala@cert.mincom.tn Page

More information

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 14 to 18 December EMC standards

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 14 to 18 December EMC standards Training Course on Conformity and Interoperability, Tunis-Tunisia, from 14 to 18 December 2015 EMC standards Presented by: Karim Loukil & Kaïs Siala Kaim.wakil@cert.mincom.tn Kais.siala@cert.mincom.tn

More information

CP-E range Benefits and advantages

CP-E range Benefits and advantages Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A

More information

Conducted emission pre compliance measurements

Conducted emission pre compliance measurements Conducted emission pre compliance measurements All electronic products need to be tested for electromagnetic emissions that may negatively effect the correct operation of other equipment nearby. Electromagnetic

More information

TEST REPORT. Information technology equipment

TEST REPORT. Information technology equipment TEST REPORT Information technology equipment Report Reference No.... 272750TRFEMC Tested by G. Bazzi (project handler)... (name, function and signature)... Approved by G. Curioni (name, function and signature)...

More information

Efficiency (1) 110Vac 220Vac. 350 ma 90 ~ 305 Vac 274 Vdc 96 W 92.0% EUC-096S035ST(7) EUC-096S035DT(7)

Efficiency (1) 110Vac 220Vac. 350 ma 90 ~ 305 Vac 274 Vdc 96 W 92.0% EUC-096S035ST(7) EUC-096S035DT(7) LED Driver EUC096SxxxST/DT 20101221 A Features Ultra High Efficiency (Up to 92%) High Power Factor (0.99 Typical) Constant Current Output Lightning Protection Dimming Function AllRound Protection: OVP,

More information

~W~~~ Laboratory Accreditation Program

~W~~~ Laboratory Accreditation Program ~ ~.en) National Voluntary ~W~~~ Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Dayton T. Brown, Inc. 1195 Church Street Bohemia, NY 11716 Ms. Mary Alice Der Aris Phone:

More information

150 Watt Industrial (WLT)

150 Watt Industrial (WLT) 150 Watt Industrial (WLT) Features 4 x 2 x 1.3 inches form factor 150 W with forced-air cooling Class 1 & Class 2 options 12 V @ 0.5 A fan voltage auxiliary output High efficiency > 86% Low conducted and

More information

Overcurrent Protection / 7SJ45

Overcurrent Protection / 7SJ45 Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC. 110 North Olinda Place Brea, CA Steve Behm Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC. 110 North Olinda Place Brea, CA Steve Behm Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CKC LABORATORIES, INC. 110 North Olinda Place Brea, CA 92823 Steve Behm Phone: 209 966 5240 ELECTRICAL (EMC) Valid to: March 31, 2019 Certificate Number: 0803.02

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Max. Output Power. Efficiency (1) 110Vac 220Vac

Max. Output Power. Efficiency (1) 110Vac 220Vac LED Driver EUV150SxxxST 20100531 H Features Ultra High (Up to ) High Power Factor (0.99 Typical) 150 W Continuous Power Lightning Protection AllRound Protection: OVP, OCP, SCP, OTP Waterproof (IP67) Comply

More information

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec This value-packed VuSpec represents the most complete resource available for professional engineers looking for best practices

More information

Emerging Standards for EMC Emissions & Immunity

Emerging Standards for EMC Emissions & Immunity Emerging Standards for EMC Emissions & Immunity Requirements for Industrial, Scientific, Medical & Information Technology Equipment CE Marking requirements are the path to increased market access Powerful

More information

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight IEC 1-1-2 4th Edition Compliant BF (Body Floating) Rated Class II Construction for Home Health Care Applications Class I With Functional Ground Connection 3 x 5 Footprint ua @ 264VAC Earth Leakage Current

More information

Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC)

Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC) Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC) Applicant: Instrument type: 1. General requirements NOTE: Definitions are based on

More information

DOBLE F6150SV TECHNICAL SPECIFICATIONS

DOBLE F6150SV TECHNICAL SPECIFICATIONS DOBLE F6150SV TECHNICAL SPECIFICATIONS The F6150sv line of System Simulators is designed for simulation tests on relay and protection schemes. There are four distinct models for your specific testing needs.

More information

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC 10KV Lightning Surge Protection Smart Over-Temperature Protection Universal AC Input up to 305Vac High Efficiency (Up to 92%) Active Power Factor Correction Constant Current With Dimming Options Waterproof

More information

By order of American Power Conversion Holdings Inc. at New Taipei, Taiwan. Author : Harry Deng Reviewed : Tim Yan Pages : 53 pages Annex : NIL

By order of American Power Conversion Holdings Inc. at New Taipei, Taiwan. Author : Harry Deng Reviewed : Tim Yan Pages : 53 pages Annex : NIL 4338754.50 EMC Test report for Multiple Protable Socket-outlets with SPD Models PM5-GR, PM5-RS, PM5-SP, PM5-UK, PM5U-GR, PM5U-RS, PM5U-UK, PM5U-SP, PM5V-GR, PM5V-RS, PM5V-SP, PM5V-UK, PM5T-GR, PM5T-RS,

More information

MID energy meter B21 Single-phase energy meter, 65 A

MID energy meter B21 Single-phase energy meter, 65 A MID energy meter B2 Single-phase energy meter, 5 Single-phase energy meter ( + ) Direct connection up to 5 Width, 2 DI modules Tested and approved per MID * and IEC * Regional different requirements apply

More information

CE EMC TEST REPORT. MANUFACTURER : TP-Link Technologies Co., Ltd.

CE EMC TEST REPORT. MANUFACTURER : TP-Link Technologies Co., Ltd. CE EMC TEST REPORT REPORT NO. : EH6D2816-01 MODEL NO. : Archer VR2800 RECEIVED DATE : Dec. 28, 2016 FINAL TESTED DATE : Mar. 31, 2017 ISSUED DATE : Apr. 06, 2017 TEST STANDARD : EN 301 489-1 V1.9.2 (2011-09),

More information

EUROPEAN pr ETS TELECOMMUNICATION November 1995 STANDARD

EUROPEAN pr ETS TELECOMMUNICATION November 1995 STANDARD DRAFT EUROPEAN pr ETS 300 447 TELECOMMUNICATION November 1995 STANDARD Source: ETSI TC-RES Reference: DE/RES-09009 ICS: 33.060.20, 33.100 Key words: EMC, test, VHF FM broadcasting transmitters Radio Equipment

More information

Typical Efficiency (2)

Typical Efficiency (2) LUC042SxxxDSW(SSW) Rev. B 42W Constant Current IP20 Driver Features High Efficiency (Up to ) Active Power Factor Correction (Typical 0.95) Cascade Connection Adjustable Constant Output Current with Dip

More information

Doc. EA Model Number:

Doc. EA Model Number: VPS-030AAC Series / VPS-030AAC 030AAC Highlights & Features VPS-030AAC05, 12, 15, 24 Meet DOE Level VI & ErP 2017 Low touch current. Suitable for type BF applications Detachable AC plug with multiple country

More information

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015. TEST REPORT Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015 Issued for: Shenzhen Flus Technology Co., Ltd 3rd Floor, Lantian Building,

More information

C E R T I F I C A T I O N

C E R T I F I C A T I O N C E R T I F I C A T I O N Applicant Address Manufacturer Address : American Power Conversion Holding Inc. Taiwan Branch : 3F., No. 205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan R.O.C.

More information

EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325

EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325 Page 1 of 39 EMC TEST REPORT For Shenzhen Scotle Technology Ltd CNC ROUTER Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325 Test Report Number : ESTBA151101209E SHENZHEN

More information

Technical Criteria for the Accreditation Of Electromagnetic Compatibility (EMC) And Radio Testing Laboratories

Technical Criteria for the Accreditation Of Electromagnetic Compatibility (EMC) And Radio Testing Laboratories Technical Criteria for the Accreditation Of Electromagnetic Compatibility (EMC) And Radio Testing Laboratories ACIL - American Council of Independent Laboratories 1629 K Street, NW, Washington, DC 20006-1633

More information

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H): 065APS18 B Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring The first Real-Time Protection and Automation platform that can be adapted to a wide variety of applications. While

More information

Not for print. Microphone Test Device with SONNET MTD Adapter. User Manual. Cochlear Implants NOT FOR PRINT

Not for print. Microphone Test Device with SONNET MTD Adapter. User Manual. Cochlear Implants NOT FOR PRINT Cochlear Implants Microphone Test Device with SONNET MTD Adapter User Manual AW32690_1.0 (English) Table of contents 1. Table of contents 2. INTRODUCTION 3 Product description 3 3. INTENDED USE INDICATIONS

More information

TEST REPORT. Power Spout PLT V. tested to the specification

TEST REPORT. Power Spout PLT V. tested to the specification EMC Technologies (NZ) Ltd PO Box 68-307 Newton, Auckland 1145 New Zealand Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT Power Spout PLT 100

More information

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O Product data sheet Characteristics RE22R2MMU Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output

More information

AUTOMOTIVE CURRENT TRANSDUCER FLUXGATE TECHNOLOGY CAB 300-C/SP3-XXX

AUTOMOTIVE CURRENT TRANSDUCER FLUXGATE TECHNOLOGY CAB 300-C/SP3-XXX AUTOMOTIVE CURRENT TRANSDUCER FLUXGATE TECHNOLOGY CAB 300-C/SP3-XXX Introduction The CAB family is for battery monitoring applications where high accuracy and very low offset are required. Features Transducer

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3 KEYSIGHT TECHNOLOGIES, INC. SERVICE CENTERS 1346 Yellowwood Rd Kimballton, IA 51543 Brandt Langer Phone: 712 254 5100

More information

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter. Features Regulated Converters Description Long 5 Year Warranty 2MOPP/250VAC Suitable for built in Class II Applications Wide Input Voltage Range (85-264VAC) Low Leakage Current (

More information