1 Introduction Test Specification Environment Relevant standards Emissions Immunity...
|
|
- Maurice White
- 5 years ago
- Views:
Transcription
1
2 CONTENTS 1 Introduction Test Specification Environment Relevant standards Emissions Immunity Test Results Conducted emissions (9kHz to 30MHz) Radiated emissions (30MHz to 1000MHz) Magnetic emissions (9kHz to 30MHz) (Not UKAS accredited) Radiated Electromagnetic Disturbance (9kHz to 30MHz) (Not UKAS accredited) Harmonic emissions Summary Emissions Immunity Compliance statement Appendices Appendix 1 Conducted emission test method (9kHz to 150kHz) Test information Appendix 2 Conducted emission test method (150kHz to 30MHz) Test information Appendix 3 Harmonic emissions test method (50 to 2000Hz) Test information Appendix 4 Radiated emission test method (30MHz to 1000MHz) Test information Appendix 5 Radiated electromagnetic disturbance test method (9kHz to 30MHz) Test information Appendix 6 Conducted emission test results Appendix 7 Radiated emission test results Appendix 8 Magnetic emission test results (Loop Antenna) Appendix 9 Radiated electromagnetic disturbance test results (Van Veen Loop) Appendix 10 Harmonic emissions test results Appendix 11 EUT test configurations Appendix 12 Reporting the results Appendix 13 Equipment used Appendix 14 Exercising equipment used York EMC Services Page 2 of 38 Issue 1
3 5.15 Appendix 15 Modification States York EMC Services Page 3 of 38 Issue 1
4 1 Introduction Name and address of laboratory: York EMC Services Ltd Three Lane Ends Business Centre Methley Road Castleford West Yorkshire WF10 1PN UKAS testing laboratory N 1574 Name and address of client: Radiocommunications Agency Wyndham 180 Marsh Wall London E14 9SX The test results contained in this test report relate only to the unit(s) tested. Equipment under test EUT 5 Printer switched mode power supply Manufacturer Product name Model number Serial number No. tested of each item Customer supplied test plan ref. Delta Electronics EUT 5 Printer power supply ADP 12XB REV:B N/A One York EMC Services Ltd Document 8214CR2 Date of receipt of EUT 20 th May 2003 Method of receipt Posted by Customer Date(s) of test(s) 20 th, 21 st, 22 nd, 23 rd, 27 th, 28 th, 29 th and 30 th May 2003 Date(s) when EUT was out of None laboratory s control Method of disposal Awaiting dispatch Personnel witnessing tests All tests witnessed by Mr Mahesh Dudhia of the Radiocommunications Agency. York EMC Services Page 4 of 38 Issue 1
5 Any other relevant information: EUT 5 denotes that the printer switched mode power supply was equipment under test number 5 out of a total of 10. During the tests the power supply was subjected to a number of load conditions (25, 50 and 100%), which were set using an external load box consisting of capacitor and resistors. This was built by York EMC Services Ltd as part of an overall project to study the EMC emissions from switched mode power supplies and similar switched electronic load controllers under different load conditions. York EMC Services Page 5 of 38 Issue 1
6 2 Test Specification 2.1 Environment The equipment under test normally forms part of a desktop printer manufactured by Lexmark. 2.2 Relevant standards Emissions Product Specific Standard EN55022:1998 Basic Standard Class/limit Test Radiated emissions EN55022:1998 Conducted emissions ac power port EN55022:1998 (See Note 4) Conducted emissions ac power port EN55015:2000+A1: 2001 (See Note 3) Magnetic emissions EN55011:1998 (Pre-compliance) Van Veen Loop EN55015:2000+A1: 2001 (See Note 3) Harmonic emissions EN :2000 B 4 B 1 Limits as per table 2a 1 As defined in table 3b 5 As defined in table 3 2 D 3 Note 1: The EUT is to be tested in three modes of operation unless specifically stated otherwise. Note 2: The individual tests were specifically requested by the customer, in order that direct comparisons could be made with a number of similar EUTs. Note 3: York EMC Services is not currently accredited for testing to EN55015:2000+A1:2001 but is accredited for testing to the earlier standard EN55015:1996. The limits and methods of measurement for the radiated disturbance test (Van Veen Loop) are identical in both standards. Note 4: Conducted emission measurements made in the frequency range 9kHz to 150kHz were compared against limit line in EN55015:2000+A1:2001. Note 5: The customer requested a class D limit for harmonic emissions for in order direct comparisons can be made between items for the purposes of the investigation, a common limit was used to test all items. York EMC Services Page 6 of 38 Issue 1
7 2.2.2 Immunity No immunity testing was requested. York EMC Services Page 7 of 38 Issue 1
8 3 Test Results 3.1 Conducted emissions (9kHz to 30MHz) Mode of operation Description Mode No. 230V AC, 100% load 1 230V AC, 50% load 2 230V AC, 25% load 3 Test standard Test description Class/limit EN55022:1998 Conducted emissions ac power (150kHz-30MHz) B EN55015:2000+A1:2001 Conducted emissions ac power (9kHz-150kHz) Limit as per table 2a Results Mode Figure Result Comments 1 C01 Pass Live C02 Pass Neutral 2 C03 Pass Live C04 Pass Neutral 3 C05 Pass Live C06 Pass Neutral QP Mode Freq QP level Comments Results (MHz) (dbuv) Live Live York EMC Services Page 8 of 38 Issue 1
9 QP Mode Freq QP level Comments Results (MHz) (dbuv) Live Live Live Live Average Mode Freq Av level Comments Results (MHz) (dbuv) Live Live Live Live Live Live QP Mode Freq QP level Comments Results (MHz) (dbuv) Neutral Neutral Neutral Neutral Neutral Neutral York EMC Services Page 9 of 38 Issue 1
10 Average Mode Freq Av level Comments Results (MHz) (dbuv) Neutral Neutral Neutral Neutral Neutral Neutral QP Mode Freq QP level Comments Results (MHz) (dbuv) Live Live Live Live Live Live Average Mode Freq Av level Comments Results (MHz) (dbuv) Live Live Live Live Live Live York EMC Services Page 10 of 38 Issue 1
11 QP Mode Freq QP level Comments Results (MHz) (dbuv) Neutral Neutral Neutral Neutral Neutral Neutral Average Mode Freq Av level Comments Results (MHz) (dbuv) Neutral Neutral Neutral Neutral Neutral Neutral QP Mode Freq QP level Comments Results (MHz) (dbuv) Live Live Live Live York EMC Services Page 11 of 38 Issue 1
12 QP Mode Freq QP level Comments Results (MHz) (dbuv) Live Live Average Mode Freq Av level Comments Results (MHz) (dbuv) Live Live Live Live Live Live QP Mode Freq QP level Comments Results (MHz) (dbuv) Neutral Neutral Neutral Neutral Neutral Neutral York EMC Services Page 12 of 38 Issue 1
13 Average Mode Freq Av level Comments Results (MHz) (dbuv) Neutral Neutral Neutral Neutral Neutral Neutral Note 1: The mains cable to the EUT was shortened to 1m as required by the standard. Modifications Required for this test Modification state None 0 York EMC Services Page 13 of 38 Issue 1
14 3.2 Radiated emissions (30MHz to 1000MHz) Mode of operation Description Mode No. 230V AC, 100% load 1 230V AC, 50% load 2 230V AC, 25% load 3 Test standard Test description Class/limit EN55022:1998 Radiated emissions B Results Mode Figure Result Comments 1 R01 Pass Both polarisations, all 4 sides of EUT. (Chamber measurement) 2 R02 Pass Both polarisations, all 4 sides of EUT. (Chamber measurement) 3 R03 Pass Both polarisations, all 4 sides of EUT. (Chamber measurement) Note 1: Due to the low level of emissions measured from the EUT, no OATS measurements were made at the request of the customer. Modifications Required for this test Modification state None 0 York EMC Services Page 14 of 38 Issue 1
15 3.3 Magnetic emissions (9kHz to 30MHz) (Not UKAS accredited) Mode of operation Description Mode No. 230V AC, 100% load 1 230V AC, 50% load 2 230V AC, 25% load 3 Test standard Test description Class/limit EN55011:1998 Radiated emissions Limit as defined in table 3b Results Mode Figure Result Comments 1 R01 Pass One face of EUT, antenna parallel to EUT. R02 Pass One face of EUT, antenna perpendicular to EUT. 2 R03 Pass One face of EUT, antenna parallel to EUT. R04 Pass One face of EUT, antenna perpendicular to EUT. 3 R05 Pass One face of EUT, antenna parallel to EUT. R06 Pass One face of EUT, antenna perpendicular to EUT. Note 1: The magnetic emissions tests were carried as pre-compliance tests at a distance of 3m, with a fixed antenna height in an anechoic chamber. During the tests the front face of the EUT was facing the antenna. Only one face was tested, (See Appendix 9, magnetic emissions 5.9.3). Modifications Required for this test Modification state None 0 York EMC Services Page 15 of 38 Issue 1
16 3.4 Radiated Electromagnetic Disturbance (9kHz to 30MHz) (Not UKAS accredited) Mode of operation Description Mode No. 230V AC, 100% load 1 230V AC, 50% load 2 230V AC, 25% load 3 Test standard Test description Class/limit EN55015:2000+A1:2001 Radiated emissions N/A Results Mode Figure Result Comments 1 R01 Pass Loop H1 R02 Pass Loop V1 R03 Pass Loop V2 2 R04 Pass Loop H1 R05 Pass Loop V1 R06 Pass Loop V2 3 R07 Pass Loop H1 R08 Pass Loop V1 R09 Pass Loop V2 Note 1: York EMC Services is not currently accredited for testing to EN55015:2000+A1:2001 but is accredited for testing to the earlier standard EN55015:1996. The limits and methods of measurement for the radiated disturbance test (Van Veen Loop) are identical in both standards. Modifications Required for this test Modification state None 0 York EMC Services Page 16 of 38 Issue 1
17 3.5 Harmonic emissions Mode of operation Description Mode No. 230V AC, 100% load 1 230V AC, 50% load 2 230V AC, 25% load 3 Test standard Test description Class/limit EN :2000 Harmonic emissions D Results Mode Figure Result Comments 1 H01 Fail None 2 H02 Fail None 3 H03 Fail None Note 1: The customer requested class D limit for harmonic emissions in order to perform a direct comparison between the items for the purposes of this investigation. A common limit was used to test all three items. Modifications Required for this test Modification state None 0 York EMC Services Page 17 of 38 Issue 1
18 4 Summary 4.1 Emissions Product Specific Standards EN55022:1998 and EN55015:2000+A1:2001 Basic Standard Class/limit Result Radiated emissions EN55022:1998 B Pass (Case A) Conducted emissions ac power port EN55022:1998 (See Note 4) Conducted emissions ac power port EN55015:2000+A1:2001 (See Note 3) Magnetic emissions EN55011:1998 (Pre-compliance) Van Veen Loop EN55015:2000+A1:2001 (See Note 3) Harmonic emissions EN :2000 B Limits as per table 2a As defined in table 3b As defined in table 3 D Pass (Case A) Pass (Case A) Pass (Case A) Pass (Case A) Fail (Case D) Note 1: The EUT is to be tested in three modes of operation unless specifically stated otherwise. Note 2: The individual tests were specifically requested by the customer, in order that direct comparisons could be made with a number of similar EUTs. Note 3: York EMC Services is not currently accredited for testing to EN55015:2000+A1:2001 but is accredited for testing to the earlier standard EN55015:1996. The limits and methods of measurement for the radiated disturbance test (Van Veen Loop) are identical in both standards. Note 4: Conducted emission measurements made in the frequency range 9kHz to 150kHz were compared against limit line in EN55015:2000+A1:2001. Note 5: The customer requested a class D limit for harmonic emissions for in order direct comparisons can be made between items for the purposes of the investigation, a common limit was used to test all items. York EMC Services Page 18 of 38 Issue 1
19 4.2 Immunity No immunity testing was requested. 4.3 Compliance statement The EUT 5 Printer switched mode power supply, was shown to meet the requirements of the standards listed in 4.1 of this report, with the exception of harmonic emissions. York EMC Services Page 19 of 38 Issue 1
20 5 Appendices 5.1 Appendix 1 Conducted emission test method (9kHz to 150kHz) Test information Standard YES Test Method Measurement uncertainty EN55015:2000+A1:2001 CEP19 +/- 1.76dB Equipment Used Rohde & Schwarz ESHS10 receiver Rohde & Schwarz ESH3-Z5 LISN Chase 9206 transient limiter Note: Specific set-ups for the EUT are shown in EUT test configurations section of this report (where applicable). York EMC Services Page 20 of 38 Issue 1
21 5.2 Appendix 2 Conducted emission test method (150kHz to 30MHz) Test information Standard YES Test Method Measurement uncertainty EN55022:1998 CEP19 +/- 2.38dB Equipment Used Rohde & Schwarz ESHS10 receiver Rohde & Schwarz ESH3-Z5 LISN Chase 9206 transient limiter Note: Specific set-ups for the EUT are shown in EUT test configurations section of this report (where applicable). York EMC Services Page 21 of 38 Issue 1
22 5.3 Appendix 3 Harmonic emissions test method (50 to 2000Hz) Test information Standard YES Test Method Measurement uncertainty EN :2000 CEP17 Greater of 5% of limit or 0.2% of rated current Equipment Used Schaffner Profline Test System Serial No Consisting of: Voltech PM3000A Analyser Serial No CCN2000 Interface Serial No. IN UPC-32 Controller Serial No AMXT Magnetics module Serial No Note: Specific set-ups for the EUT are shown in EUT test configurations section of this report (where applicable). York EMC Services Page 22 of 38 Issue 1
23 5.4 Appendix 4 Radiated emission test method (30MHz to 1000MHz) Test information Standards YES Test Method Measurement uncertainty EN55022:1998 CEP23 N/A Equipment Used Rohde & Schwarz receiver Bilog antenna Rohde & Schwarz positioning mast and controller EMCO 2m diameter turntable and controller Note: Specific set-ups for the EUT are shown in EUT test configurations section of this report (where applicable). York EMC Services Page 23 of 38 Issue 1
24 5.5 Appendix 5 Radiated electromagnetic disturbance test method (9kHz to 30MHz) Test information Standards YES Test Method Measurement uncertainty EN55015:2000+A1:2001 CEP20 +/- 2.36dB Equipment Used Rohde & Schwarz receiver Van Veen Loop Variac Note: Specific set-ups for the EUT are shown in EUT test configurations section of this report (where applicable). York EMC Services Page 24 of 38 Issue 1
25 5.6 Appendix 6 Conducted emission test results Conducted Emission (Live) Peak Measurement Conducted Emission (dbuv) Frequency (MHz) 100% Load 50% Load 25% Load Noise Floor Quasi-Peak - 100% Load Quasi-Peak - 50% Load Quasi-Peak - 25% Load Limit EN QP Figure Conducted emissions results, (Live quasi peak measurement). Conducted Emission (Live) Average Measurement Conducted Emission (dbuv) Frequency (MHz) 100% Load 50% Load 25% Load Noise Floor AV - 100% Load AV- 50% Load AV - 25% Load Limit EN AV Figure Conducted emissions results, (Live average measurement). York EMC Services Page 25 of 38 Issue 1
26 Conducted Emission (Neutral) Peak Measurement Conducted Emission (dbuv) % Load 50% Load frequency 25% (MHz) Load Noise Floor Quasi-Peak - 100% Load Quasi-Peak - 50% Load Quasi-Peak - 25% Load Limit EN55015 and EN QP Figure Conducted emissions results, (Neutral quasi peak measurement). Conducted Emission (Neutral) Average Measurement Conducted Emission (dbuv) frequency (MHz) 100% Load 50% Load 25% Load Noise Floor AV - 100% Load" AV - 50% Load" AV - 25% Load" Limit EN AV Figure Conducted emissions results, (Neutral average measurement). York EMC Services Page 26 of 38 Issue 1
27 5.7 Appendix 7 Radiated emission test results Combined Horizontal & Vertical Polarisations Peak Measurement Radiated Emissions (dbuv/m) Frequency (MHz) Noise Floor 100% Load 50% Load 25% Load Limit EN55022 Class B Figure Radiated emissions results (Chamber). Note 1: The frequencies at approximately 90MHz 100MHz, and MHz were ambient signals. York EMC Services Page 27 of 38 Issue 1
28 5.8 Appendix 8 Magnetic emission test results (Loop Antenna) Parallel Loop Peak Measurement Magnetic Field (dbua/m) Frequency (MHz) Noise Floor 25% Load 50% Load 100% Load Limit EN QP Figure Magnetic emissions results, parallel (Chamber). Perpendicular Loop Peak Measurement Magnetic field (dbua/m) Frequency (MHz) Noise Floor 25% Load 50% Load 100% Load Limit EN QP Figure Magnetic emissions results, perpendicular (Chamber). York EMC Services Page 28 of 38 Issue 1
29 5.9 Appendix 9 Radiated electromagnetic disturbance test results (Van Veen Loop) Van Veen Peak Measurement (Loop H1) Radiated Emission (dbua/m) % Load 50% Load frequency (MHz) 25% Load Noise Floor Quasi-Peak - 100% Load Quasi-Peak - 50% Load Quasi-Peak - 25% Load Limit EN QP Figure Magnetic emissions results (loop H1). Van Veen Peak Measurement (Loop V1) Radiated Emission (dbua/m) % Load 50% Load frequency (MHz) 25% Load Noise Floor Quasi-Peak - 100% Load Quasi-Peak - 50% Load Quasi-Peak - 25% Load Limit EN QP Figure Magnetic emissions results (loop V1). York EMC Services Page 29 of 38 Issue 1
30 Van Veen Peak Measurement (Loop V2) Radiated Emission (dbua/m) % Load 50% Load frequency (MHz) 25% Load Noise Floor Quasi-Peak - 100% Load Quasi-Peak - 50% Load Quasi-Peak - 25% Load Limit EN QP Figure Magnetic emissions results (loop V2). York EMC Services Page 30 of 38 Issue 1
31 5.10 Appendix 10 Harmonic emissions test results EUT ma % limit Mode 1 100% Mode 2 50% Mode 3 25% Harmonics Figure Harmonic emissions results. York EMC Services Page 31 of 38 Issue 1
32 5.11 Appendix 11 EUT test configurations Photograph Conducted emissions testing Photograph Radiated emissions testing York EMC Services Page 32 of 38 Issue 1
33 Photograph Magnetic emissions testing (Loop antenna) Photograph Magnetic emissions testing (Van Veen Loop) York EMC Services Page 33 of 38 Issue 1
34 Photograph Harmonic emissions testing York EMC Services Page 34 of 38 Issue 1
35 5.12 Appendix 12 Reporting the results Case A Case B Case C Case D Specified upper limit Specified lower limit = Reported value Case A The equipment complies with the stated specification of the measured points, due allowance having been made for the uncertainty of the measurements. It may be deemed as a pass. Case B The measured result is below the specification limit by a margin less than the measurement uncertainty; it is therefore not possible to state compliance based on the stated level of confidence. However the result indicates that compliance is more probable than non-compliance with the specification limit. It is a likely pass but within the measurement uncertainty. Case C The measured result is above the specification limit by a margin less than the measurement uncertainty; it is therefore not possible to state compliance based on the stated level of confidence. However the result indicates that non-compliance is more probable than compliance with the specification limit. It is a likely fail but within the measurement uncertainty. Case D The equipment does not comply with the stated specification of the measured points, due allowance having been made for the uncertainty of the measurements. It may be deemed as a fail. York EMC Services Page 35 of 38 Issue 1
36 5.13 Appendix 13 Equipment used Equipment No. Cal Type Used Equipment No. Cal Type Used AR FM2000 Field Probe Set R&S SMY02 Signal Generator UKAS AR FM2000 Field Probe Set UKAS Rolfe Heine 200A 3 Phase LISN UKAS AR50W W Amplifier NCS Rolfe Heine 32A 3 Phase LISN UKAS Blackstar Function Generator In-house Schaffner NSG1025 EFT/B Generator UKAS Chase Van Veen Loop In-house! Schaffner NSG2025 EFT/B Generator UKAS Chase CBL 6111A Bilog Antenna UKAS Schaffner NSG PNW UKAS Chase CBL 6112B Bilog Antenna UKAS Schaffner EM clamp NCS Chase CBL 6140 X-Wing Antenna In-house! Chase CFL 9206 Transient Limiter In-house Schaffner NSG435 ESD Simulator UKAS Chase CFL 9206 Transient Limiter In-house! Chase HLA6120 Loop Antenna NPL! Schaffner NSG650 + CDN UKAS Chase MDS21 Absorbing Clamp UKAS Schaffner NSG PNW UKAS EMCO 3115 Double Ridged Horn Manufac Schaffner Profline UKAS! Fischer FCC-801-M1-16 CDN UKAS Schaffner voltage probe CVP UKAS Fischer FCC-801-M2-25 CDN UKAS Schaffner current probe SMZ UKAS Fischer FCC-801-M2-16 CDN UKAS Schaffner T200 ISN UKAS Fischer FCC-801-M3-16 CDN UKAS Schaffner T400 ISN UKAS Fischer FCC-801-M3-25 CDN UKAS Schaffner Chase CBL6111C UKAS Fischer FCC-801-M4-25 CDN UKAS Schaffner Chase CBL6112B Manufac Fischer EM clamp NCS Schaffner INA 175 surge CDN In-house Fischer FCC-801-T UKAS Schaffner INA 172 surge CDN In-house Fluke 45 Digital Mutimeter UKAS Solar 9108-IN Current Probe UKAS Fluke 85 Digital Mutimeter UKAS Voltech PM3000A Harmonic Analyser UKAS! Gould 475 Digital Oscilloscope UKAS Fischer FCC-801-M3-25 CDN UKAS HP Infinium oscilloscope UKAS Fischer FCC-801 M1-16 CDN UKAS HP programmable power supply UKAS EM Test UCS UKAS Instek GFG-8020H In-house Fischer FCC-801-M1-16 CDN ISO-TECH ICA32N current transducer NCS Fisher FCC-801-M3-25 CDN UKAS ISO-TECH 9053 LCR meter NCS Keytek AC line qualifier UKAS Keytek EMC Pro UKAS Spitzenberger & Spies power source NCS Keytek MZ-15/EC ESD Simulator UKAS 6dB attenuator In-house LEM HEME LH2015 true RMS meter NCS 6dB attenuator In-house Marconi UKAS Magnetic immunity loop (single) In-house R&S ESH3-Z5 LISN UKAS Magnetic immunity loop (multi) In-house R&S ESH3-Z5 LISN UKAS! Wandel & Golterman EFA Manufac R&S ESHS 10 Receiver UKAS! Schaffner EFT/B clamp In-house R&S ESHS10 Receiver UKAS! Variac N/A! R&S ESVS 30 Receiver UKAS! R&S ESVS10 Receiver UKAS York EMC Services Page 36 of 38 Issue 1
37 5.14 Appendix 14 Exercising equipment used Equipment Serial number Cal status Load box 12 N/A None York EMC Services Page 37 of 38 Issue 1
38 5.15 Appendix 15 Modification States Modification state Modification 0 As supplied by the customer. York EMC Services Page 38 of 38 Issue 1
Test Report (pdf copy) EMC Testing of Platinum Infrared Gas Sensor with screen not connected to 0V For Dynament Ltd
Test Report (pdf copy) EMC Testing of Platinum Infrared Gas Sensor with screen not connected to 0V For Dynament Ltd Document number 11378/TR/1 Project number C1453 Author:... Mr D Horry EMC Technician
More informationReport for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B
Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed
More informationReport for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027
Report for Excelsys on EMC Measurements for 6Xgen Purchase Order: by email Project Number EMT08J027 Tom O Brien, Engineering Director ElectroMagnetic Technologies Ltd, Cork, June 2007 Executive Summary
More informationPage: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003
Page: 1 of 20 EMC TEST REPORT Reference No. Applicant : WT05060412 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Cable Standards Model No : UAS111-M, UAS111, UAS112 : EN55022:1998+A2:2003
More informationCE TEST CERTIFICATION
according to Certification No.: E5NC004 European Standard EN 61000-6-4:2001 EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 61000-6-2:2001 ( IEC 61000-4-2:1995/A1:1998, IEC 61000-4-3: 1995/A1:1998,
More informationEMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight
EMC Bayswater Pty Ltd 52 Holloway Drive Bayswater, Victoria, 3153, Australia Telephone: +61 3 9762 4111 Facsimile: +61 3 9762 8519 Email: sales@emcbayswater.com.au ABN: 49 112 221 333 EMC COMPLIANCE REPORT
More informationCompliance Engineering Ireland Ltd
Page 1 of 27 Compliance Engineering Ireland Ltd RAYSTOWN, RATOATH ROAD, ASHBOURNE, CO. MEATH, IRELAND Tel: +353 1 8256722 Fax: +353 1 8256733 Project Number: 10E2475-5 Prepared for: Biancamed Ltd By Compliance
More informationCE TEST CERTIFICATION
Certification No.: E5DC001 according to European Standard EN 61000-6-4:2001 EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 61000-6-2:2001 ( IEC 61000-4-2:1995/A1:1998, IEC 61000-4-3: 1995/A1:1998,
More informationCE EMC Test Certification
Certification No.: EC57C001 CE EMC Test Certification According to European Standard EN 55022:1998/A1:2000/A2:2003 Class A, EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 55024:1998/A1:2001/A2:2003
More informationTest Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification
Test Report: 5R46150.1 Applicant: Equipment Under Test: Model Number: In Accordance With: Tested By: Nanoptix Inc. 699 Champlain Street Dieppe, New Brunswick E1A 1P6 Spill Proof Cuts SPC FCC 47 CFR Part
More informationEMC TEST REPORT. Oina VV AB. Dispenser system. Accurate speedcontrol BLDC/ Report no: Approved by Tobias Gustavsson
EMC TEST REPORT Oina VV AB Dispenser system Accurate speedcontrol BLDC/ Report no: 09007 Prepared by Ulf Heiding Approved by Tobias Gustavsson Date 2009-01-23 This report may not be reproduced other than
More informationTEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed
17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:
More informationEN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments
EMC Page 3 / 33 Test report No.: EN 61000-6-3:2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: 2013-10-16
More informationEN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass
Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz
More informationShenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20
Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC125641 Page: 1 of 20 EMC Test Report Application No. : TB12114299 Applicant : Newmb Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : USB HUB
More informationEMC COMPLIANCE TEST REPORT
EMC COMPLIANCE TEST REPORT Technical Statement of Conformity in accordance with the council directive 2004/108/EC The product Equipment Under Test Model Number Product Series Report Number Issue Date Test
More informationDate: ESPOO Page: 1 ( 10) Appendices - Transceiver. SATELLINE-EASy Pro 35W SATEL-TA18 SATEL Oy, Finland
Version R3.03 09092003 TEST REPORT Date: ESPOO 05.10.2010 Page: 1 ( 10) Appendices - Number: 157439 No. 1 / 1 Date of handing in: 17.09.2010 Tested by: Timo Hietala, Test Engineer Reviewed by: Timo Leismala,
More informationTEST REPORT. PolyComp 32X80P7.621YHB Electronic Sign. tested to the. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices
EMC Technologies (NZ) Ltd PO Box 68-307 Newton, Auckland Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT PolyComp 32X80P7.621YHB Electronic
More informationHarmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass
Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,
More informationNemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2
www.nemko.com Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2 Report Number: Product Marketing Name: 123766-1TRFEMC Paycheck 4 Thermal Ticket Printer Test Specification: FCC
More informationTEST REPORT. Power Spout PLT V. tested to the specification
EMC Technologies (NZ) Ltd PO Box 68-307 Newton, Auckland 1145 New Zealand Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT Power Spout PLT 100
More informationDATES OF TESTS: From 03/10/2014 to 20/10/2014 and 25/02/2015. Open area test site in Aunainville (28) - FRANCE. Page 2 out of 54
TEST CERTIFICATION FOR: FCC Certification NAME OF THE EQUIPMENT UNDER TEST: Serial number: Wireless conference access point Type: CONFIDEA WCAP G3 1440077150000C1 Reference / model (P/N): 71.98.0033 V
More informationF C C - TESTREPORT REPORT NO.: FCC-02/
F C C - TESTREPORT REPORT NO.: FCC-02/09-0010 pkm Ohmstrasse 1 D-84160 Frontenhausen Tel : 08732-6381 Fax : 08732-2345 e-mail: pkm.accredited-labs@t-online.de Seite/page: 2 of 12 TABLE OF CONTENTS Page
More informationFCC Part 15 Subpart B
Report No.: 15A111603E-F Page 1 of 23 Test Report FCC Part 15 Subpart B for Electromagnetic Interference of Product: Managed PoE Industrial Ethernet Switch Trade Name: N/A Model Number: IS-DG512P-2F-8;
More informationDiscontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz
Reference No.: WTU15U0933879E Page 2 of 45 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationCE EMC CERTIFICATION
according to Certification No.: EC78C004-01 European Standard EN 55022:2006 Class A, EN 61000-3-2:2000, EN 61000-3-3:1995/A1:2001 and EN 55024:1998/A1:2001/A2:2003 ( IEC 61000-4-2:1995/A2:2000, IEC 61000-4-3:2002,
More informationSatec Ltd. 3-Phase Power Meter PM135
DATE: 07 August 2012 I.T.L. (PRODUCT TESTING) LTD. CE EMC Test Report for Satec Ltd. Equipment under test: 3-Phase Power Meter PM135 Written by: Y. Raz, Documentation Approved by: Y. Mordukhovitch, Test
More informationDiscontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz
Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationPage: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6
Page: 1 of 41 EMC TEST REPORT Reference No. Applicant : WT05060416 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Multi-socket with surge protection Standards Model No. : SPG3-B-10,
More informationEN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U
EN 301 489-17 v1.2.1 (2002-08) TEST REPORT FOR 802.11n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U11615-3 ISSUE DATE: FEBRUARY 29, 2008 Prepared for ATHEROS COMMUNICATIONS, INC.
More informationC E R T I F I C A T I O N
C E R T I F I C A T I O N Applicant Address Manufacturer Address : American Power Conversion Holding Inc. Taiwan Branch : 3F., No. 205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan R.O.C.
More information: M Leach, Principal EMC Engineer.
EMC Test Report : TTR-002356GUS2 Applicant : Pace plc. Apparatus : RNG210n Authorised by : : M Leach, Principal EMC Engineer. Issue Date : 16 th November 2010 Authorised Copy Number : PDF grepbl.doc Ver:
More informationContent. Report No. SH Page 2 of 22
Page 2 of 22 Content SUMMARY...1 1. GENERAL INFORMATION...3 1.1 Description of Equipment Under Test (EUT)...3 1.2 Description of Client...3 1.3 Description of Test Facility...3 2. TEST SPECIFICATIONS...4
More informationPage: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK
Page: 1 of 46 Reference No. Applicant : WT05060414 EMC TEST REPORT : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Advanced surge protection Model No. : SISF, SISF-2, SISFN-BLACK,
More informationECHOSTAR 54.0 BRISBANE VOICE REMOTE 2017 MODEL: URC-2027BC0-R
Page 1 of 17 FCC PART 15, SUBPART B and C TEST REPORT for ECHOSTAR 54.0 BRISBANE VOICE REMOTE 2017 MODEL: URC-2027BC0-R Prepared for UNIVERSAL ELECTRONICS, INC. 201 E. SANDPOINTE, 8 TH FLOOR SANTA ANA,
More informationEMISSION TEST REPORT
Page 1 of 23 EMISSION TEST REPORT Test Report No. Applicant Address Manufacturer Address Type of Equipment Model Name Serial number Total page of Report : E05OR-057 : Win4NET Co., Ltd. : KOLON Digital
More informationTest Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,
Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of, EN 301 489-1 V1.8.1 Electromagnetic compatibility and
More informationCERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01
CERTIFICATE Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01 This is to certify that the following designated product Product : 19 inch Rack-mounted Data Acquisition Computer Trade name : Moxa
More informationSTC Test Report. The Hong Kong Standards and Testing Centre Ltd.
Date: 2011-11-15 Page 2 of 15 CONTENT: Cover Page 1 of 15 Content Page 2 of 15 1.0 General Details 1.1 Equipment Under Test [EUT] Page 3 of 15 Description of sample(s) 1.2 Description of EUT operation
More informationTEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:
10050333 001 Seite 2 von 19 Page 2 of 19 TEST SUMMARY 5.1 CONDUCTED EMISSION PER SECTION 15.107, FCC 47 CFR PART 15 SUBPART B RESULT: Pass 5.2 RADIATED EMISSION PER SECTION 15.109, FCC 47 CFR PART 15 SUBPART
More informationTEST REPORT. Power Spout PLT V. tested to the specification. EN : Amendment 1: Electromagnetic compatibility (EMC)
EMC Technologies (NZ) Ltd PO Box 68-307, Newton Auckland 1145 New Zealand Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT Power Spout PLT 100
More informationTRANSMITTER MODEL: KAS-2030M
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for TRANSMITTER MODEL: KAS-2030M Prepared for WILDLIFE TECHNOLOGIES 115 WOLCOTT STREET MANCHESTER, NEW HAMPSHIRE 03103 Prepared by: KYLE FUJIMOTO Approved
More informationFCC 15B Test Report. : BTv4.0 Dual Mode USB Dongle. Address : Thompson Ave. / Lenexa, Kansas / / USA
FCC 15B Test Report Equipment Model No. Brand Name Applicant : BTv4.0 Dual Mode USB Dongle : BT820 : Laird Technologies : Laird Technologies Address : 11160 Thompson Ave. / Lenexa, Kansas / 66219 / USA
More informationEMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009
Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203
More informationENGINEERING TEST REPORT
ENGINEERING TEST REPORT NUMBER: 10216476EICES1 ON Model No.(s): BB-BONE-000 IN ACCORDANCE WITH: ICES-003, ISSUE 4: 2004 TESTED FOR: Circuitco Electronics 1380 Presidential, Suite 100 Richardson, Texas
More informationEMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.
Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial
More informationTest Report According to EN V1.9.2; EN V Starcom GPS Systems Ltd.
DATE: 06 October 2014 I.T.L. (PRODUCT TESTING) LTD. Test Report According to EN 301 489-1 V1.9.2; EN 301 489-7 V1.3.1 for Starcom GPS Systems Ltd. Equipment under test: Container Tracker Triton R Written
More informationEMC T E S T R E P O R T
Registration No. DAT-P-207/05 EMC T E S T R E P O R T Test Report No. : E33047-00-00NL 04. November 2008 Date of issue Type / Model Name : HCP Best Product Description : Cash register with integrated GPRS
More informationTABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...
TABLE OF CONTENTS 1. SUMMARY OF TEST RESULTS... 4 2. GENERAL INFORMATION... 5 2.1 Details of E.U.T.... 5 2.2 Description of Support Device... 5 2.3 Block Diagram of Test Setup... 5 2.4 Test Facility...
More informationTest Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification
Test Report: 4R08185.1 Applicant: Equipment Under Test: Nanoptix Inc. 699 Champlain Street Dieppe, New-Brunswick E4P 8L6 EZ-Tear FX Model Number: 102103 In Accordance With: FCC 47 CFR Part 15, Subpart
More informationC E R T I F I C A T I O N
C E R T I F I C A T I O N Applicant Address Manufacturer Address : American Power Conversion Holding Inc. Taiwan Branch : 3F., No. 205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan R.O.C.
More informationEMC Test Report. Report No.: AGC EE01 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.
Page 1 of 38 EMC Test Report PRODUCT DESIGNATION BRAND NAME MODEL NAME CLIENT : Dual Band Mobile Radio : VGC : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.,LTD DATE
More informationEMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45
REPORT NO. PRSZ15110502E EMC TEST REPORT For Boardcon Technology Limited. MINI9G45 Computer on Module Model No. : MINI9G45 Prepared For : Boardcon Technology Limited. : Room 702, Hua Feng Xin An Business
More informationEMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)
EMC TEST REPORT For Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) Prepared For : Company Limited Liability «Faraday
More informationAUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN
AUSTRALIA TEST REPORT For KLM Lighting Co., Limited LED Down Light Model No.: KLM-HP30WSN Additional Model No.: KLM-SM-50-002, KLM-HP7WSS, KLM-HP10WSS, KLM-HP12WSS, KLM-HP15WSS, KLM-HP20WSS, KLM-HP30WSS,
More informationC-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply
C-Tick EMC TEST REPORT For AC/DC Switching Power Supply Model: CP0515(5V/1.5A); CP0520(5V/2A); CP0530 (5V/3A); CP0540 (5V/4A); CP0550 (5V/5A); CP0560 (5V/6A);CP0615(6V/1.5A); CP0620(6V/2A); CP0625 (6V/2.5A);
More informationDongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS
TABLE OF CONTENTS 1. SUMMARY OF TEST RESULTS... 4 2. GENERAL INFORMATION... 5 2.1 Details of E.U.T.... 5 2.2 Description of Support Device... 5 2.3 Block Diagram of Test Setup... 5 2.4 Test Facility...
More informationLS200 TEST DATA IEC61000 SERIES
TEST DATA IEC61000 SERIES DWG. No. PA607-58-01 APPD CHK DWG TDK-Lambda INDEX LS200 PAGE 1. Electrostatic Discharge Immunity Test (IEC61000-4-2) R-1 2. Radiated Radio-Frequency Electromagnetic Field Immunity
More informationFCC PART 15 B MEASUREMENT AND TEST REPORT
FCC PART 15 B MEASUREMENT AND TEST REPORT For FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, 47100 PUCHONG, SELANGOR, MALAYSIA MODEL: Keylock 8800 April 12, 2010 This Report Concerns:
More informationITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA
Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU
More informationC E R T I F I C A T I O N
C E R T I F I C A T I O N Applicant Address Manufacturer Address : American Power Conversion Holding Inc. Taiwan Branch : 3F., No. 205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan R.O.C.
More information1 - GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES...
TABLE OF CONTENTS 1 - GENERAL INFORMATION... 3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)... 3 1.2 TEST STANDARDS... 3 1.3 TEST SUMMARY... 3 1.4 TEST METHODOLOGY... 4 1.5 TEST FACILITY... 4
More informationOUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT Prepared for MINASKA OUTDOORS 6517 PLATTE AVENUE LINCOLN, NEBRASKA 68507 Prepared by: KYLE FUJIMOTO
More informationLABORATORIUM VOOR OMGEVINGSMETINGEN LABORATOIRE D ESSAIS D ENVIRONNEMENT ENVIRONMENTAL TEST LABORATORIA
LABORATOIRE D ESSAIS D ENVIRONNEMENT COMPETENT BODY UNDER CEC-DIRECTIVE 2004/108/CE NOTIFIED BODY UNDER CEC-DIRECTIVE 2006/95/CE ACCREDITED FOR NBN EN ISO 17025 BY BELAC 041-T - ISO17025 041-T - ISO17025
More information2004/104/EC Measurement and Test Report
2004/104/EC Measurement and Test Report For LM Technologies Ltd. Unit19, Spectrum House, 32-34, Gordon House Road, London, NW5 1LP, United Kingdom Compliance Directive: Product Description: 2004/104/EC
More informationEMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.
DONGGUAN FIT-WATCH CO., LTD. EMC REPORT Prepared For : DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province Product Name : Trade Name : Model
More informationAPPENDIX A. GENERAL DESCRIPTION OF EQUIPMENT UNDER TEST
APPENDIX A. GENERAL DESCRIPTION OF EQUIPMENT UNDER TEST A.1. Applicant CHUNDE TECHNOLOGY CO., LTD NO. 136, Mingshan 10th St., Renwu Dist, Kaohsiung City 814, Taiwan (R.O.C.) A.2. Applicant Same as 1.1
More informationItron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:
Itron, Inc. TEST REPORT FOR RF Telemetry Device Model: CCU100 Tested To The Following Standards: FCC Part 15 Subpart C Sections 15.247 and RSS 210 Issue 8 Date of issue: April 25, 2013 This test report
More informationMeasurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob
Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob For Caterpillar Inc. 330 S.W. Adams Street Peoria, IL 61630 P.O. Number JBL 11260 Date Tested May 11, 2016 Test Personnel Mark Longinotti
More informationBS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE
Page 1 of 18 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel
More informationFCC Certification Test Report for the MEI Cashflow RFID Reader Base FCC ID: QP8EASITRAXRB
for the FCC ID: QP8EASITRAXRB WLL JOB# 9915 September 21, 2007 Prepared for: 1301 Wilson Drive West Chester, PA 19380 Prepared By: Washington Laboratories, Ltd. 7560 Lindbergh Drive Gaithersburg, Maryland
More informationTest Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.
Test Report Product Name Model No. FCC ID. IC ID. WPC Qi 1.1/1.0 compliance wireless charging micro-usb box Wireless Charger MSQ-ASUSWLCHARGER 3568A-ASWLCHARGER Applicant ASUSTeK COMPUTER INC. Address
More informationTEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.
TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD. Test Of: Wood & Douglas Ltd ST500 Transmitter Test Report Serial No: RFI/EMCB2/RP39403B This Test Report supersedes RFI Test Report No.: RFI/EMCB1/RP39403B
More informationSTC Test Report. Date : Page 1 of 13 No. : HM161169
Date : 2009-05-11 Page 1 of 13 Applicant (ATS001): Atech Scientific Measurement Limited. Room A-C, 18 Floor, Luk Hop Ind. Bldg, 8 Luk Hop Street, Kowloon Manufacturer: Atech Scientific Measurement Limited.
More informationReport No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for
Report No.: 9A042401C2 Page 1 of 36 EN 50121-4: 2006 Product: Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client Trade Name: MOXA Model Number: AWK-5222 Prepared for MOXA Inc. Fl.4, No.135, Lane 235,
More informationFCC PART 15 B MEASUREMENT AND TEST REPORT
FCC PART 15 B MEASUREMENT AND TEST REPORT For FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, 47100 PUCHONG, SELANGOR, MALAYSIA MODEL: i-kadex August 11, 2009 This Report Concerns:
More informationEMC Test Report. Report Number: M030826
Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report
More informationEMC TEST REPORT For Prokits Industries Co., Ltd.
Page 1 of 34 EMC TEST REPORT For Prokits Industries Co., Ltd. Temperature-Controlled Soldering Station Model No.:SS-206/207 Series Test Report Number : ESTSZ110701228E EST COMPLIANCE LABORATORY LIMITED
More informationTEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C
TEST REPORT For RFID READER/WRITER In conformity with FCC CFR 47 Part15 Subpart C Model: TR3XM-SD01 / TR3XM-SU01 / TR3XM-SN01 FCC ID: MK4TR3XM-SX01 Test Item: RFID READER/WRITER Report No: RY1203Z12R1
More informationSunlight Supply, Inc.
FCC Part 18 Subpart C Non-Consumer For RF Lighting Equipment Electromagnetic Compatibility Test Report Sunlight Supply, Inc. Commercial Ballast 1000 Watt - July 18, 2017 Tests Conducted by:, LLC 20811
More informationPage 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.
Page 1 of 20 FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER Equipment Under Test [EUT]: Model Number: Applicant: FCC ID : Radio Controlled Tank FH002 Zhongshan Fu Hai Electronics
More informationTest Report. Product Name: Cable Modem Model No.: BEFCMU10 ver.3 FCC ID. : Q87-BEFCMU10V3
Report No. 036H064FI Test Report Product Name: Cable Modem Model No.: BEFCMU10 ver.3 FCC ID. : Q87-BEFCMU10V3 Applicant : Cisco-Linksys, LLC Address : 17401 Armstrong Avenue, Irvine, CA 92614 USA Date
More informationDeclaration of Conformity
Declaration of Conformity We, Manufacturer ZIPPY TECHNOLOGY CORP. 10F,No.50,MIN CHYUAN RD. SHIN-TIEN, TAIPEI HSIEN TAIWAN, R.O.C. declare that the product (description of the apparatus, system, installation
More informationTable of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...
Table of Contents 1. GENERAL INFORMATION... 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST... 4 1.2 RELATED SUBMITTAL(S) / GRANT (S)... 7 1.3 TEST METHODOLOGY... 7 1.4 EQUIPMENT MODIFICATIONS... 7
More informationDATE: 10 February 2010 I.T.L. (PRODUCT TESTING) LTD. CE EMC Test Report. for. MAXIMUM Security (1984) Ltd. Equipment under test:
DATE: 10 February 2010 I.T.L. (PRODUCT TESTING) LTD. CE EMC Test Report for MAXIMUM Security (1984) Ltd. Equipment under test: MULTI-ZONE, OUT-SMART, GUARD, OUT-LOOK, CURTAIN-FLT, CURTAIN-2PM, CURTAIN,
More informationFCC CLASS B COMPLIANCE REPORT (DoC)
FCC CLASS B COMPLIANCE REPORT (DoC) for Electromagnetic Emissions Of ENTRY LEVEL IP PHONE Trade Name : XONTEL Model Number : XT-19P Serial Number : N/A Report Number : PZD1611741-F Date : Regulations :
More informationTest Report. : 09A255R-ITCEP28V01 Report Version : V1.0
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Test Report Product Name : Industrial IEEE 802.11a/b/g dual-rf Access Point/Bridge/Client Model No. : AWK-6222-xx-y
More informationFCC Verification TEST REPORT
FCC Verification TEST REPORT Product: 5 in 1 Environment Meter Model no.: ET-965 Trade Mark: N/A Report No.: TCT140915E005 Issued Date: Sep. 22, 2014 Issued for: Shenzhen Flus Technology Co., Ltd 3rd Floor,
More informationEMC VERIFICATION SUMMARY Report No.: SZHH
EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA
More informationTest Report. Product Name : Access Point Model No.: MS-6809 FCC ID.: I4L-MS6809
Test Report Product Name : Access Point Model No.: MS-6809 FCC ID.: I4L-MS6809 Applicant : MICRO-STAR INT L Co., LTD Address : No 69, Li-De st., Jung-He City, Taipei Hsien, Taiwan, R.O.C Date of Receipt
More informationFCC 47 CFR PART 15 SUBPART B
FCC 47 CFR PART 15 SUBPART B TEST REPORT For DC TO DC CONVERTER Model : D100 Series Issued for MicroPower Direct, LLC 232 Tosca Drive Stoughton, MA02072 U.S.A. Issued by Compliance Certification Services
More informationaccording to AS/NZS :1999 Door Entry Alarm System YUAN HSUN ELECTRIC CO., LTD.
according to AS/NZS 4251.1:1999 EQUIPMENT MODEL NO. APPLICANT Door Entry Alarm System DES-700 YUAN HSUN ELECTRIC CO., LTD. NO. 57, CHUNG HE RD., ZUO-YING DIST., KAOHSIUNG CITY 813, TAIWAN, R. O. C. TEST
More informationTest Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Test of: CIBS To: FCC Part 15.247: 2008 Subpart C, RSS-210 Issue 7 June 2007 & RSS-Gen Issue 2 June 2007 Test Report Serial No: RFI/RPT2/RP75103JD05A Supersedes Test Report
More informationTest Report for Part 15
Test Report for Part 15 Report number: STD-FCC-11020 Type of EUT: Speed Dome Camera Model number: Family Model: DOH-240SE DSC-230SE, DSC-270SE, DSC-600SE, DSC-300SE, DSC-300SE5, DSC-728SE, DSC-737SE Applicant:
More informationTest Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC
Test Report Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC Applicant : MICRO-STAR INT L Co., LTD Address : No 69, Li-De st., Jung-He City, Taipei Hsien, Taiwan, R.O.C Date
More informationEN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A
Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result
More informationENGINEERING TEST REPORT NUMBER: EUS1. ON Model No.(s): BB-BONE-000 IN ACCORDANCE WITH: CFR 47, PART 15, SUBPART B, CLASS B VERIFICATION
ENGINEERING TEST REPORT NUMBER: 10216476EUS1 ON Model No.(s): BB-BONE-000 IN ACCORDANCE WITH: CFR 47, PART 15, SUBPART B, TESTED FOR: Circuitco Electronics 1380 Presidential, Suite 100 Richardson, Texas
More informationTest Report No
x Test Report No.8312314587 For Synel Industries Ltd. Equipment Under Test: Proximity Reader From The Standards Institution Of Israel Industry Division Telematics Laboratory EMC Section Certificate No.
More informationTABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12
TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-12 3.2 Radiated Emission Tests 13-15 3.3 Radiated Electromagnetic disturbance Test 16-20
More information