1 EMC Technologies (NZ) Ltd PO Box Newton, Auckland 1145 New Zealand Phone Fax Address: Web Site: TEST REPORT Power Spout PLT V tested to the specification EN : 2007 Electromagnetic compatibility (EMC): Part 6 - Generic standards Section 1 Immunity for residential, commercial and light industrial environments for Ecoinnovation Ltd This Test Report is issued with the authority of: Andrew Cutler General Manager Page 1 of 16 Test Report No th July 2013

2 Table of Contents 1. STATEMENT OF COMPLIANCE 3 2. RESULTS SUMMARY 3 3. INTRODUCTION 5 4. CLIENT INFORMATION 5 5. DESCRIPTION OF TEST SAMPLE 5 6. SETUPS AND PROCEDURES 6 7. TEST RESULTS TEST EQUIPMENT USED ACCREDITATIONS PHOTOGRAPHS 16 Page 2 of 16 Test Report No th July 2013

3 1. STATEMENT OF COMPLIANCE The Power Spout PLT V Hydro Turbine complies with EN : RESULTS SUMMARY The results from testing on 9 th July 2013, are summarised in the following tables: Table 1: Enclosure Port Test Power Frequency Magnetic Field 50 Hz, 3 A/m Radio Frequency Electromagnetic Field MHz, 3 V/m MHz, 3 V/m MHz, 1 V/m 1 khz tone 80% AM Modulated Electrostatic Discharge. ± 8 kv air discharge, ± 4 kv contact discharge Result Not applicable. Device does not contain any magnetically sensitive devices. Complies. Meets Criterion A. Complies. Meets Criterion B. Table 2: Signal ports Test Conducted RF Susceptibility MHz, 3 V rms, 1 khz tone 80% AM modulated Fast Transients. +/- 0.5 kv 5/50 Tr/Th ns, 5 khz repetition frequency. Result DC generating device with no signal ports. DC generating device with no signal ports. Page 3 of 16 Test Report No th July 2013

4 Table 3: Input and output DC ports. Test Conducted RF Susceptibility MHz, 3 V rms, 1 khz tone 80% AM modulated Surges. +/- 0.5 kv line to ground & line to line 1.2/50 (8/20) Tr/Th us Fast Transients. +/- 2.0 kv, 5/50 Tr/Th ns, 5 khz repetition Result Complies. Meets Criterion A. DC generating device. DC generating device. Table 4: Input and output AC power ports. Test Conducted RF Susceptibility MHz, 3 V rms, 1 khz tone 80% AM modulated Voltage dips 100% dip for 0.5 cycles 100% dip for 1.0 cycle 30% dip for 25 cycles Voltage interruptions. 100% interruption for 250 cycles Surges. 1.2/50 (8/20) Tr/Th us line to ground +/- 2.0 kv line to line +/- 1.0 kv Fast Transients. +/- 1.0 kv, 5/50 Tr/Th ns, 5 khz repetition frequency. Result DC generating device. The device is not AC powered. DC generating device. DC generating device. DC generating device. Page 4 of 16 Test Report No th July 2013

5 3. INTRODUCTION This report describes the tests and measurements for the purpose of determining compliance with the specification under the following conditions: The client selected the test sample. This report relates only to the sample tested. This report contains no corrections or erasures. Measurement uncertainties with statistical confidence intervals of 95% are shown below test results. Both class A and Class B uncertainties have been accounted for, as well as influence uncertainties where appropriate. 4. CLIENT INFORMATION Company Name Address Ecoinnovation Ltd 671 Kent Rd City RD1 New Plymouth 4371 Country Contact New Zealand Michael Lawley 5. DESCRIPTION OF TEST SAMPLE Brand Name Power Spout. Model Numbers PLT V. Product Manufacturer Country of Origin Hydro Turbine. Ecoinnovation Ltd New Zealand Serial Number - Page 5 of 16 Test Report No th July 2013

6 Manufacturer s Statement Page 6 of 16 Test Report No th July 2013

7 Page 7 of 16 Test Report No th July 2013

8 Page 8 of 16 Test Report No th July 2013

9 Page 9 of 16 Test Report No th July 2013

10 6. SETUPS AND PROCEDURES Standard The sample was tested in accordance with EN : Test Method Standard Criteria Electrostatic Discharges EN B RF Radiated Immunity EN A Electrical Fast Transient bursts EN B Surges EN B Radio Frequency Conducted Immunity EN A Power Frequency Magnetic Immunity EN A Voltage Dips EN B Voltage Interruptions EN C The latest version, including any amendments, of each standard was referenced. Performance Criterion A: The apparatus shall continue to operate as intended during the test. No degradation of performance or loss of function is allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the apparatus is used as intended. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended. Performance Criterion B: The apparatus shall continue to operate as intended during the test. No degradation of performance or loss of function is allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the apparatus is used as intended. During the test, degradation of performance is allowed however. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended. Page 10 of 16 Test Report No th July 2013

11 Performance Criterion C: Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by the operation of the controls, or by any operation specified in the instructions for use. Test set up Testing was performed on the PLT V model of the product family. All models covered by this report are electrically identical with the 240V model determined to be worst case. The device is a hydro-powered turbine that produces a DC output that is either connected to an inverter or a battery bank in normal operation. The device uses a flow of water, such as that provided by a stream, to spin the turbine to generate DC power. A 3-phase induction motor was used to drive the turbine which produced an output of 220 Vdc. The dc voltage output was then connected to a resistive heating element that was placed in a container of water. The testing was performed in accordance with the manufacturer s performance criteria where the device was required to still be active at the end of the test. At the conclusion of each test the internal Klampit circuit was exercised to ensure it was still operational. This was performed by disconnecting the load and reattaching it. The Klampit circuit in normal operation should drop the turbine s output voltage to 0.3V from its nominal 220 Vdc output. Page 11 of 16 Test Report No th July 2013

12 7. TEST RESULTS Electrostatic Discharge (ESD) ESD testing was required to be carried out with air and contact discharges being applied as detailed below. The device was required to meet performance criteria B. Described below are the calibration uncertainties for Electrostatic Discharge to IEC DC Voltage 0.04% - Peak Current 4% - Rise Time 2.5% - Curve decay points at 30 and 60 ns 5% ESD testing was carried out with ± 8 kv air discharges and ± 4 kv contact discharges being applied. As unit is not table mounted no Horizontal Coupling Plane testing was performed. 10 x ± 2 kv, ± 4 kv Contact discharges were applied at one second intervals as follows: Point of Contact Observation Result Vertical Coupling Plane ( Base of EUT) No effects observed Pass VCP (Top of EUT) No effects observed Pass VCP (Left side of EUT) No effects observed Pass VCP (Right side of EUT) No effects observed Pass Case Bolts (x4) No effects observed Pass Case Crews (base of unit (x4) No effects observed Pass 10 x ± 2 kv, ± 4 kv, ± 8 kv Air discharges were applied at one second intervals as follows: Point of Contact Observation Result Casing No effects observed Pass Turbine cover No effects observed Pass Casing Vents No effects observed Pass Cable Gland No effects observed Pass Water pipes (x2) No effects observed Pass Result: Complies. The device did not display susceptibility to Electrostatic Discharges during the test and did not change state. The device s Klampit circuit operated normally after the test. Page 12 of 16 Test Report No th July 2013

13 Radio Frequency Electromagnetic Field RF Electromagnetic Field testing was required to be carried out at 3 V/m, between MHz with a 1 khz tone being 80% AM modulated. Testing was carried out in 1% steps with a 3 second dwell time. Testing was carried out using a bilog antenna in both vertical and horizontal polarisations. The device was required to meet performance criteria A. Described below are the calibration uncertainties for Radiated Susceptibility to EN : MHz ± 1.1 V/m The Radiated RF was injected into the top and cable egress faces of the device. Observations: No effects were observed. Result: Complies. The device did not display susceptibility to Conducted RF Electromagnetic Fields throughout the test. The device s Klampit circuit operated normally after the test. Page 13 of 16 Test Report No th July 2013

14 Conducted RF Susceptibility Conducted RF susceptibility testing was carried out between 150 khz and 80 MHz at a level of 3 V/m. Testing was carried out in 1% steps and a 3 second dwell time with a 1 khz tone being 80% AM modulated. The device was required to meet performance criteria A. The calibration uncertainties for Radio frequency continuous conducted susceptibility to EN are: MHz ± 1.42 db The following ports/lines were tested: Port Tested Method Observation Result DC Output CDN No effects observed Pass Result: Complies. The device did not display susceptibility to Conducted RF Electromagnetic Fields throughout the test. The device s Klampit circuit operated normally after the test. Page 14 of 16 Test Report No th July 2013

15 8. TEST EQUIPMENT USED Instrument Manufacturer Model Serial No Ref Anechoic Material Rantec ESP24 2 Cones - - Biolog Antenna Emco E1596 Coupling Network CIM CDN-DC2-16A - E3792 ESD Gun Schaffner NSG E1426 Measurement Probe Amplifier Research FP Measurement Receiver Amplifier Research FM Mircowave RF Amplifier Ophir 5162FE 1029 E3786 Power Amplifier IFI M75 B Power Amplifier IFI SMX Signal Generator Rohde & Schwarz SMP E ACCREDITATIONS The tests were carried out in accordance with the terms of EMC Technologies (NZ) Ltd s International Accreditation New Zealand (IANZ) Accreditation to NZS/IEC/ ISO All measurement equipment has been calibrated in accordance with the terms of EMC Technologies (NZ) Ltd s International Accreditation New Zealand (IANZ) Accreditation to NZS/IEC/ ISO International Accreditation New Zealand has Mutual Recognition Arrangements for testing and calibration with various accreditation bodies in a number of economies. This includes NATA (Australia), UKAS (UK), SANAS (South Africa), NVLAP (USA), A2LA (USA), SWEDAC (Sweden). Further details can be supplied on request. Page 15 of 16 Test Report No th July 2013

16 10. PHOTOGRAPHS Page 16 of 16 Test Report No th July 2013

TEST REPORT. Power Spout PLT V. tested to the specification. EN : Amendment 1: Electromagnetic compatibility (EMC)

TEST REPORT. Power Spout PLT V. tested to the specification. EN : Amendment 1: Electromagnetic compatibility (EMC) EMC Technologies (NZ) Ltd PO Box 68-307, Newton Auckland 1145 New Zealand Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT Power Spout PLT 100

More information

TEST REPORT. PolyComp 32X80P7.621YHB Electronic Sign. tested to the. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices

TEST REPORT. PolyComp 32X80P7.621YHB Electronic Sign. tested to the. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices EMC Technologies (NZ) Ltd PO Box 68-307 Newton, Auckland Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT PolyComp 32X80P7.621YHB Electronic

More information

EMC Test Report. Report Number: M030826

EMC Test Report. Report Number: M030826 Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report

More information

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments EMC Page 3 / 33 Test report No.: EN 61000-6-3:2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: 2013-10-16

More information

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE Page 1 of 18 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel

More information

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE

More information

TEST REPORT... 1 CONTENT...

TEST REPORT... 1 CONTENT... CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2

More information

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result

More information

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz Reference No.: WTU15U0933879E Page 2 of 45 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result

More information

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan Page 1 of 32 EMC TEST REPORT Report No.: TS11020117-EME Model No.: NS-PSE, NS-POINTED, NS-PSQUARE, NS-PF-S, NS-PT, NS-PR, NS-PU, NS-PF-H, NS-BALIBA, NS-FLEXMA Issued Date: Mar. 01, 2011 Applicant: NORTE

More information

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name: Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013

More information

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,

More information

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result

More information

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017 EN 301 489-17 v3.1.1 TEST REPORT FOR Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017 Prepared for Texas Instrument 2900 Semiconductor Drive Santa

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25 15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE

More information

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz

More information

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC. Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial

More information

BS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C

BS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C Page 1 of 23 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel

More information

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by

More information

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province. DONGGUAN FIT-WATCH CO., LTD. EMC REPORT Prepared For : DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province Product Name : Trade Name : Model

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27 15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE

More information

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by  Project Number EMT08J027 Report for Excelsys on EMC Measurements for 6Xgen Purchase Order: by email Project Number EMT08J027 Tom O Brien, Engineering Director ElectroMagnetic Technologies Ltd, Cork, June 2007 Executive Summary

More information

EMC test report AU01+E04

EMC test report AU01+E04 Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E04 This test report may not be copied or published in a part without the written authorization of

More information

ELECTRONICS TESTING CENTER(ETC), TAIWAN

ELECTRONICS TESTING CENTER(ETC), TAIWAN File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 1 / 35 TEST REPORT Responsible Party Manufacturer Description of Product Trade Name : Huan Vu Enterprise Co., Ltd. : Huan Vu Enterprise Co.,

More information

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC VERIFICATION SUMMARY Report No.: SZHH EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA

More information

Communication Certification Laboratory

Communication Certification Laboratory Communication Certification Laboratory November 29, 2006 Mr. Samuel Smith Adept Systems Inc. 2966 Fort Hill road Eagle Mountain, UT 84005 Dear Sam: Communication Certification Laboratory has completed

More information

BUREAU VERITAS. itaste svd

BUREAU VERITAS. itaste svd BUREAU VERITAS TEST REPORT No.: (5213)095-0238 TEST REPORT To: INNOKIN TECHNOLOGY CO., LTD I Fax: I -- Attn: -- I -- I Address: Buildinq 6, XinXinTian Industrial Park, XinSha Road, Sha.Jinq street, ShenZhen,

More information

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed

More information

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU

More information

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi EMC TEST REPORT For Shenzhen Ruideou Keji Youxian Gongsi Product Name: Trademark: Milligram Scale WAOAW Model Number: W-01-50 Prepared For : Address: Prepared By : Address: Shenzhen Ruideou Keji Youxian

More information

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758 Page 1 of 20 Report No. R011604553E EMC TEST REPORT for DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., LTD. Electronic calculator Model No.: KF15758 Prepared for Address Prepared by Address : DONGGUAN EVER

More information

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203

More information

EMC Test report for LED Panel Light Models , , , , ,

EMC Test report for LED Panel Light Models , , , , , 4326247.50 EMC Test report for LED Panel Light Models 000529, 000530, 000531, 000532, 000535, 000536 Guangzhou, date of issue: 2016-02-24 Author:Jazz Liang By order of Marvo Verlichting B.V. at Hoogeveen,

More information

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003 Page: 1 of 20 EMC TEST REPORT Reference No. Applicant : WT05060412 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Cable Standards Model No : UAS111-M, UAS111, UAS112 : EN55022:1998+A2:2003

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger

Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 ISERT (Pty) Ltd. Reg: 2017/186396/07 Tel: + 27 (0)12 548 0940 E-Mail: info@isert.co.za 129 Khai-Apple street Montana Pretoria 0186 EMC TEST

More information

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U EN 301 489-17 v1.2.1 (2002-08) TEST REPORT FOR 802.11b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U10459-6 ISSUE DATE: JULY 31, 2006 Prepared for ATHEROS COMMUNICATIONS, INC. 5480 GREAT

More information

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20 Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC125641 Page: 1 of 20 EMC Test Report Application No. : TB12114299 Applicant : Newmb Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : USB HUB

More information

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of, Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of, EN 301 489-1 V1.8.1 Electromagnetic compatibility and

More information

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CGZ3150428-00472-E-R1 2/F., South Tower, Huoju Building, No.181, Canghai Road,

More information

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China 4317137.50 EMC Test report for LED Fixed luminaires Models LED12036-1R, LED12036-2TU, LED120363R, LED12036-4TU2, LED12036-6TR, LED12036-1R CHR, LED12036-2TU CHR, LED12036-3R CHR, LED12036-4TU2 CHR, LED12036-6TR

More information

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 Prepared for Address : ShenZhen ZhangQing Electronic LTD :

More information

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed 17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:

More information

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd. EMC Testing Report Equipment Under Test: Model Number: Serial No.: Applicant: Address of Applicant: Multi-Frequency (4 Channel Selectable) Twin Photobeam Detector Dual-120CS Dual-90CS, Dual-60CS, Dual-30CS

More information

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U EN 301 489-17 v1.2.1 (2002-08) TEST REPORT FOR 802.11n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U11615-3 ISSUE DATE: FEBRUARY 29, 2008 Prepared for ATHEROS COMMUNICATIONS, INC.

More information

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter Page 1 of 48 EMC TEST REPORT for Coliy Technology Co.,Ltd. Fluxgate Gaussmeter Prepared for : Coliy Technology Co.,Ltd. Address : Block B,9 th Floor,Xinzhongtai Business Building,Gushu 2nd Road,Xi Town,Bao

More information

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT Nemko-CCL, Inc. 1940 West Alexander Street Salt Lake City, UT 84119 801-972-6146 Test Report Declaration of Conformity Test Of: MICRO-RM2.4 Test Specifications: EN 301 489-1 V1.9.2 (2011-09) as specified

More information

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC standards. Presented by: Karim Loukil & Kaïs Siala Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards

More information

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name: APPLICATION FOR EMC DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co., Ltd led flood light Trade Name: Model: QH-TGC-400W, QH-TGC-300W, QH-TGC-500W, QH-TGC-800W, QH-TGC-1000W Prepared For : Shenzhen

More information

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007 Certificate of Test WE HEREBY CERTIFY THAT: Certificate No.: R07122709E Yuan Hsun Electric Co., Ltd. No. 57, Chung He Rd, Zuo-Ying Dist., Kaohsiung City 813, Taiwan R.O.C. Quad photobeam detector Quad-200CS

More information

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by EMC TEST REPORT For KST DIGITAL TECHNOLOGY LIMITED Coreless Servo Model No.: X12-508 Additional Model No.: DS215MG, DS315MG, DS213MG, DS313MG, DS12C, DS12T, X12-306 Prepared for Address : KST DIGITAL TECHNOLOGY

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Variant Model Name: Applicant: CAMERA HOUSING SAMSUNG TECHWIN CO., LTD. SCX-FH200B SHB-4200 SAMSUNG TECHWIN

More information

1 SUMMARY OF STANDARDS AND RESULTS

1 SUMMARY OF STANDARDS AND RESULTS 1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: EMISSION Description of Test Item Standard

More information

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE EMC TEST REPORT For SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD Product Name: Pure sine wave power inverter Trademark: Model : Prepared For : Address: Prepared By : Address: ML-1000W ML-300W---ML-8000W.

More information

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CNB3150602-00399-E 2/F., South Tower, Huoju Building, No.181, Canghai Road,

More information

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A EMC Test Report Applicant: Address of Applicant: Trade Name: FATEK AUTOMATION CORP. 26FL, NO.29, SEC.2, JUNGJENG E. RD., DANSHUEI DIST., NEW TAIPEI CITY, TAIWAN, R.O.C. FATEK Equipment Under Test: Training

More information

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B Page 1 of 27 Report No. R011412016E-1 EMC TEST REPORT for LEDELS LIGHTING CO., LTD LED module Model No. : LL-F12T4815X6B Prepared for : LEDELS LIGHTING CO., LTD Address : 5F, Block C, Mingjinhai Ind. Park,

More information

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

Test Report. Ningbo Goldmore Industrial Co.,Ltd. Test Report Applicant: Ningbo Goldmore Industrial Co.,Ltd. Product Name: Brand Name: Model No.: LED CAMPING LANTERN with FAN N/A XJH-8098 Date of Receipt : Sep. 23, 2014 Date of Test: Sep. 25, 2014 Date

More information

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG SWITCHING POWER SUPPLY Model No. HSM-50-12~48 HSM-15-5~24, HSM-35-12~48. : DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG : No.3 Tengfei Road,

More information

Test Report GUANGDONG EAST POWER CO., LTD

Test Report GUANGDONG EAST POWER CO., LTD Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA906IIRTS, EA906IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014

More information

Report on the EMC Testing. For. Exception EMS Ltd. RBK-ILS Processor. Report No. TRA A. 29 th April 2016

Report on the EMC Testing. For. Exception EMS Ltd. RBK-ILS Processor. Report No. TRA A. 29 th April 2016 Report on the EMC Testing For Exception EMS Ltd On RBK-ILS Processor Report No. TRA-028046-36-00A 29 th April 2016 RF657 7.0 Report Number: Copy Number: TRA-028046-36-00A PDF REPORT ON THE EMC TESTING

More information

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances, electric tools

More information

1 Introduction Test Specification Environment Relevant standards Emissions Immunity...

1 Introduction Test Specification Environment Relevant standards Emissions Immunity... CONTENTS 1 Introduction... 4 2 Test Specification... 6 2.1 Environment... 6 2.2 Relevant standards... 6 2.2.1 Emissions... 6 2.2.2 Immunity... 7 3 Test Results... 8 3.1 Conducted emissions (9kHz to 30MHz)...

More information

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD Page 1 of 45 Report No. R011607240E EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD INVERTER CHARGER Model No.: PV35-4K DC24V MPK, PV35-4K DC48V MPK, PV35-5K DC48V MPK, PV35-6K DC48V MPK Prepared

More information

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

Guangdong East Power Co., Ltd. Uninterruptible Power Systems Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Uninterruptible Power Systems EAST EA8806, EA8804 Date of Receipt : Nov. 01, 2012 Date of Test: Nov. 03, 2012

More information

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for Report No.: 9A042401C2 Page 1 of 36 EN 50121-4: 2006 Product: Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client Trade Name: MOXA Model Number: AWK-5222 Prepared for MOXA Inc. Fl.4, No.135, Lane 235,

More information

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan 4322705.50 EMC Test report for Plug-in adaptor Models PM1W-IT, PM1WU2-IT, PM1W-GR, PM1W-SP, PM1W-RS, PM1WB-RS, PM1WU2-GR, PM1WU2-SP, PM1WU2-RS, PM1WBU2-RS, PM1W-UK, PM1WU2-UK, PM1W-FR, PM1WU2-FR Guangzhou,

More information

EMC TEST REPORT For CE

EMC TEST REPORT For CE EMC TEST REPORT For CE Test Report No. : CTK-2013-01069 Date of Issue : 2013-07-02 Kind of Product : FnIO S-Series Basic Model/Type No. : NA-9211, ST-5725, ST-5726 Variant Model/Type No. : NA-9212 Applicant

More information

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10 TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-10 3.2 Radiated Emission Tests 11-13 3.3 Radiated Electromagnetic disturbance Test 14-18

More information

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan EMC TEST REPORT For MPP SOLAR INC Model Number: PIP 2424MS Prepare for Address : MPP Solar Inc : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan Prepare by Address : MPP Solar In : 4F, No. 50-1,

More information

LS200 TEST DATA IEC61000 SERIES

LS200 TEST DATA IEC61000 SERIES TEST DATA IEC61000 SERIES DWG. No. PA607-58-01 APPD CHK DWG TDK-Lambda INDEX LS200 PAGE 1. Electrostatic Discharge Immunity Test (IEC61000-4-2) R-1 2. Radiated Radio-Frequency Electromagnetic Field Immunity

More information

9. Electrostatic Discharge Immunity Test (ESD)

9. Electrostatic Discharge Immunity Test (ESD) 9. Electrostatic Discharge Immunity Test (ESD) Test Mode: Mode 1 Final Test Result : PASS Pass Performance Criteria : A Required Performance Criteria: B Basic Standard : IEC 61000-4-2:Edition 1.2:2001-04

More information

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS Prepared For : Prepared By : Changzhou Airwheel Technology Co.,Ltd. Fl.5, East of No. 10 Building, high-tech

More information

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23 D I R E C T O R Y A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23 B) Test data: Immunity against Electrostatic discharge

More information

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54 Equipment Under Test Brand Name Model No. Added Model(s) Applicant Address of Applicant Page : 1 of 54 TEST REPORT : AC Servo Motor : Kingservo : AC 400W servo motor : N/A : Ho Fo Automation CO., LTD :

More information

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C. EMC TEST REPORT REPORT NO. : RM110613E07 MODEL NO. : M-R0027 RECEIVED : June 13, 2011 TESTED : June 17, 2011 ISSUED : June 22, 2011 APPLICANT : LOGITECH FAR EAST LTD. ADDRESS : #2 Creation Rd. 4, Science-Based

More information

C E R T I F I C A T I O N

C E R T I F I C A T I O N C E R T I F I C A T I O N Applicant Address Manufacturer Address : American Power Conversion Holding Inc. Taiwan Branch : 3F., No. 205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan R.O.C.

More information

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12 TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-12 3.2 Radiated Emission Tests 13-15 3.3 Radiated Electromagnetic disturbance Test 16-20

More information

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT ELECTROMAGNETIC COMPLIANCE TEST REPORT For Electric nail art drill Model Name: HBS-021, HBS-278, HBS-288, HBS-530, HBS-540 Brand Name: Date of Issue: May 7, 2011 Prepared For Houbos Hardware & Electrical

More information

ELECTRONICS TESTING CENTER, TAIWAN

ELECTRONICS TESTING CENTER, TAIWAN File No.: 09-06-MAS-242-03 EMC TESTING DEPARTMENT Page:1/12 CONFORMANCE TEST REPORT FOR EN 301489-1 / -17 Report No.: 09-06-MAS-242-03 Client: Product: Model: Manufacturer/supplier: Ezurio Limited. Bluetooth

More information

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 The following information was submitted and identified by/on behalf of the client as: Applicant : Ningbo Shanhuang Electric Appliance

More information

ENGINEERING TEST REPORT #: A LSR JOB #: C-2411

ENGINEERING TEST REPORT #: A LSR JOB #: C-2411 W66 N220 Commerce Court Cedarburg, WI 53012 Phone: 262.375.4400 Fax: 262.375.4248 www.lsr.com Compliance Testing of: RM186-SM Test Date(s): 4-12-16 4-25-16 Prepared For: Attention: N. Zach Hogya Laird

More information

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45 REPORT NO. PRSZ15110502E EMC TEST REPORT For Boardcon Technology Limited. MINI9G45 Computer on Module Model No. : MINI9G45 Prepared For : Boardcon Technology Limited. : Room 702, Hua Feng Xin An Business

More information

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19 EMC TEST REPORT Page : 1 of 19 Equipment Under Test Model No. Applicant Address of Applicant : Bluetooth Headset : FB-HS01 : Formosa Teletek Corporation : 358, Huaya 2 nd Rd., Gueishan shiang, Taoyuan,

More information

TEST REPORT. Report Number: DAL-001 Project Number: G Report Issue Date: February 6, 2013

TEST REPORT. Report Number: DAL-001 Project Number: G Report Issue Date: February 6, 2013 TEST REPORT Report Number: 100943193DAL-001 Project Number: G100943193 Report Issue Date: February 6, 2013 Product Designation: Standards: Vibrating Fork Level Switch Model: RS85 CENELEC EN 61326-1*BEI

More information

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42. EMC TEST REPORT For Shenzhen Smar TEC Technology Company Smart Charger For Li-Ion&Lifepo4 Battery Pack Model No.:SPS-F12S02-021(42.6V/2A) Prepared for : Shenzhen Smar TEC Technology Company Address : 4-5/F.,

More information

EMC TEST REPORT. Report No.: CE10-LIE040101E

EMC TEST REPORT. Report No.: CE10-LIE040101E EMC TEST REPORT Report No.: CE10-LIE040101E Product: LED TUBE Model No.: T10, T8, T5 Applicant: Shenzhen Saiju Electronic Co., Ltd. Address: 2nd. Xianshun Industrial Park, Gushu, Xixiang, Bao an, Shenzhen,

More information

EMI Test Lab LLC Electro Magnetic Interference Testing EmiTestLab.com

EMI Test Lab LLC Electro Magnetic Interference Testing EmiTestLab.com Electro Magnetic Compatibility Test Report Regarding the CE Mark Compliance of the EVAL-ADICUP3029 Baseboard And EVAL-ADT4720-PMDZ PMOD board In Accordance with the Information Technology Standards EN

More information

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2 INDEX PAGE 1. Electro-Static Discharge Test EN61000-4-2.. R-1 2. Radiated Susceptibility Test EN61000-4-3 R-2 3. Electrical Fast Transient Burst Test EN61000-4-4 R-3 4. Surge Test EN61000-4-5 R-4 5. Conducted

More information

CE Testing Results and Explanation

CE Testing Results and Explanation 1500 West University Parkway Sarasota, Florida 34243 Phone 941-362-1200 Telefax 941-362-1290 www.sunhydraulics.com CE Testing Results and Explanation This article summarizes the electromagnetic compatibility

More information

Satec Ltd. 3-Phase Power Meter PM135

Satec Ltd. 3-Phase Power Meter PM135 DATE: 07 August 2012 I.T.L. (PRODUCT TESTING) LTD. CE EMC Test Report for Satec Ltd. Equipment under test: 3-Phase Power Meter PM135 Written by: Y. Raz, Documentation Approved by: Y. Mordukhovitch, Test

More information

Test Report According to EN V1.9.2; EN V Starcom GPS Systems Ltd.

Test Report According to EN V1.9.2; EN V Starcom GPS Systems Ltd. DATE: 06 October 2014 I.T.L. (PRODUCT TESTING) LTD. Test Report According to EN 301 489-1 V1.9.2; EN 301 489-7 V1.3.1 for Starcom GPS Systems Ltd. Equipment under test: Container Tracker Triton R Written

More information

EMC TEST REPORT. Oina VV AB. Dispenser system. Accurate speedcontrol BLDC/ Report no: Approved by Tobias Gustavsson

EMC TEST REPORT. Oina VV AB. Dispenser system. Accurate speedcontrol BLDC/ Report no: Approved by Tobias Gustavsson EMC TEST REPORT Oina VV AB Dispenser system Accurate speedcontrol BLDC/ Report no: 09007 Prepared by Ulf Heiding Approved by Tobias Gustavsson Date 2009-01-23 This report may not be reproduced other than

More information

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CGZ3160623-01025-E-D 2/F., South Tower, Huoju Building, No.181, Canghai Road,

More information

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight EMC Bayswater Pty Ltd 52 Holloway Drive Bayswater, Victoria, 3153, Australia Telephone: +61 3 9762 4111 Facsimile: +61 3 9762 8519 Email: sales@emcbayswater.com.au ABN: 49 112 221 333 EMC COMPLIANCE REPORT

More information

Test Report GUANGDONG EAST POWER CO., LTD

Test Report GUANGDONG EAST POWER CO., LTD Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA902IIRTS, EA902IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014

More information

EMC TEST REPORT Model: 053-EMC-TR_ING, rev. 12 del 15/05/08. Laboratory identification: L.E.M. S.r.l. UNI CEI EN ISO/IEC EMC Laboratory

EMC TEST REPORT Model: 053-EMC-TR_ING, rev. 12 del 15/05/08. Laboratory identification: L.E.M. S.r.l. UNI CEI EN ISO/IEC EMC Laboratory L.E.M. S.r.l. Notified Body (ID 2034) EMC TEST REPORT Model: 053-EMC-TR_ING, rev. 12 del 15/05/08 Laboratory identification: L.E.M. S.r.l. UNI CEI EN ISO/IEC 17025 EMC Laboratory recognized by Ministry

More information

PT. SARANA KARYA SOLUSINDO.

PT. SARANA KARYA SOLUSINDO. Shenzhen BST Technology Co., Ltd. PT. SARANA KARYA SOLUSINDO. EMC REPORT Prepared For : PT. SARANA KARYA SOLUSINDO. Puri Surya Jaya J1. 29 Cluster Vancouver, Gedangan, Sidoarjo, Jawa Timur - Indonesia

More information

EMI Test Lab LLC Electro Magnetic Interference Testing EmiTestLab.com

EMI Test Lab LLC Electro Magnetic Interference Testing EmiTestLab.com Electro Magnetic Compatibility Test Report Regarding the CE Mark Compliance of the Unintentional Emissions and Immunity of the Analog Devices PicoZed SDR (Software Defined Radio) Model number: Z7035/AD9361

More information

Laboratory Accreditation Programmes

Laboratory Accreditation Programmes Laboratory Address PO Box 68307, Newton, Auckland, 1145 47 Mackelvie Street, Grey Lynn, Auckland, 1021 Telephone 09 360-0862 Fax 09 360-0861 URL Authorised Representative Client No. 2218 Programme Accreditation

More information