Wiring Diagrams. Part B, Section 3. This section covers the following unit configurations V Issued 7/01 B3EN-05-[3V-A-AAAX]-4

Size: px
Start display at page:

Download "Wiring Diagrams. Part B, Section 3. This section covers the following unit configurations V Issued 7/01 B3EN-05-[3V-A-AAAX]-4"

Transcription

1 Part B, Section This section covers the following unit configurations. Model All Voltage All Pump All Manifold All Control All 00 Nordson Corporation -000V Issued /0 BEN-0-[V-A-AAAX]-

2 B -0 BEN-0-[V-A-AAAX]- -000V Issued /0 00 Nordson Corporation

3 B - Section B. Introduction The wiring diagrams contained in this section are based on the voltage code of your unit. Refer to the following table to determine the voltage code of your unit; then refer to the appropriate wiring diagram in this section. Unit Voltage Code Table B - Unit Voltage Codes and Applicable Specification Type of service you can connect to the unit: (See Note A) Part of this section to refer to: 00 0 Vac or AC 0 or /PE AC 00 0V 00 0 Vac (two wire service without a neutral) Voltage Code and Wiring Diagram 00 0 Vac (three wire service without a neutral) /N/PE AC 00/0V 0 Vac (two wire service, including a neutral) Voltage Code and Wiring Diagram 00/0 Vac (four wire service, including a neutral) AC 00V 00 Vac (three wire service without a neutral) Voltage Code Wiring Diagram AC 0 V 0 Vac (three wire service without a neutral) Voltage Code Wiring Diagram NOTE A: This specification is printed in the VOLTS (ac) portion of the identification plate on your unit.. Use of Each wiring diagram is contained on two facing pages. Sometimes a wire shown on one page is connected to terminals or components shown on the facing page. In these cases, the connecting wiring is labeled on each page with the same letters. For example, if you want to trace a wire or harness labeled BL on the left page, look for a wire or harness labeled BL on the right page. Each wiring diagram shows all of the options or special features the unit can be equipped with. Options and special features are indicated by dotted lines. To determine the features and options of your unit, refer to Explanation of Configuration Code at the end of the Description section. 00 Nordson Corporation -000V Issued /0 BEN-0-[V-A-AAAX]-

4 B -. Voltage Code and Wiring Diagram This wiring diagram applies to voltage code and units only. Refer to Table B - to determine the voltage code of your unit. ON/OFF I/O BK SIGNALS BM BL J F PL TB0 & TB0 XP XS XS INDICATOR DISPLAY BD I/O BOARD PC ENGINE BD X TB XP K PL J XP RS/RS COMMUNICATIONS F0 XPA XP XP F F F F F F F F F F T TBB TBC TBD KEYPAD XP XP L L L N X XP XP BOARD DIGITAL PROCESSOR BOARD TB J NOTE: FOR AC GEAR PUMP UNITS JUMPER IS USED ON J WARNING GND (PE) METAL GND FRAME FAULT XP NOT READY XP0 XP X X J J BXP NO CONNECTION XS XS XPB CE TSTAT Fig. B - Wiring Diagram for Voltage Code and Units ( of ) XP BC XPA CI CH PNEUMATIC SOLENOID VALVE (NOT USED WITH AC GEAR PUMP OPTION) TANK OVERTEMP THERMOSTAT TANK/RES G HC GUN HC GUN HC GUN HC HG HG HG GUN TANK/RES HG FRAME G REAR G FRONT G TOP COVER G EXPANSION SE PLATE G HG, HG, GRID G, AC G, G HOPPER COVER G0 PARTS IN DOTTED LINES ARE OPTIONAL GND (PE) 0A BEN-0-[V-A-AAAX]- -000V Issued /0 00 Nordson Corporation

5 B - XC & XC CONNECTIONS 00-0 V PHASE XC XC 00-0 V PHASE XC XC AC OVERTEMPERATURE THERMOSTAT M G XC 0 V PHASE XC XC 00 V/0 V PHASE XC XSC OR BM XSC OR BL AC BOARD XSM F F K K XSM M YELLOW BLUE RED S ON/OFF LED + AC XSM RUN/START (00 0 V UNITS) GUN GUN START CHOKE BK SOLENOID SOLENOID CI CH SWITCH VALVE VALVE SEE DETAIL A TRIGGER IN TO FOR 00/0 V ENABLE IN K UNITS START DETAIL A HC XP XP XP SWITCH G (SSW) XP BL OR GUN XSB PATTERN K BM OR DRIVER BOARD XSB AC RUN/START XP (00/0 V UNITS) 0 XP / HOSE/GUN BOARD XH XSH F HG CONTACTOR BOARD F HC K XH XC XC L F XSA,B,C L XSH F XSA,B,C,D F L GUN F XSA,B N XSA F XH JC JC 0 G G CC BC JUMPER WHEN HG GRID NOT GROUND STACK LIST PRESENT CE BXP BD GRID SOURCE WIRE LOCATION CG G A XGR FRAME REAR CC TSTAT G A XSGR XSGR H/G HG D H/G HG D GRID BOARD TANK/RES G A G PARTS IN DOTTED LINES ARE OPTIONAL FRONT G B TOP D X & X CONNECTIONS HG, HG COVER G B A 00-0 V PHASE 00-0 V PHASE X X G, G, G C EXP. G D SEPLATE H/G HG C B H/G HG C LEVEL H/G HG C LEVEL 00 V/0 V PHASE 0 V PHASE X X H/G HG D LEVEL GRID G B LEVEL G C LEVEL G A BRACKET HOPPER G0 B COVER X X 0A Fig. B - Wiring Diagram for Voltage Code and Units ( of ) 00 Nordson Corporation -000V Issued /0 BEN-0-[V-A-AAAX]-

6 B -. Voltage Code Wiring Diagram This wiring diagram applies to voltage code units only. Refer to Table B - to determine the voltage code of your unit. I/O BK SIGNALS PL DISPLAY BD PL TB0 & TB0 I/O BOARD J XP PC ENGINE BD XP XP XPA XP XP KEYPAD XP BOARD XP DIGITAL PROCESSOR XP NO CONNECTION BXP BE XP Y X 0 0 HC HC GUN HG GUN HG ON/OFF RS/RS COMMUNICATIONS J F INDICATOR X TB K F0 F F F F F F F F F F T TBB TBC TBD XP XP L L L N X BOARD BB BB TB WARNING FAULT NOT READY GND (PE) METAL GND FRAME X X J XS XS J Fig. B - Wiring Diagram for Voltage Code Units ( of ) TSTAT BC PNEUMATIC SOLENOID VALVE TANK OVERTEMP THERMOSTAT 0 0 HC HC GUN HG GUN HG FRAME G REAR G FRONT G TOP COVER G EXPANSION SE PLATE G PARTS IN DOTTED LINES ARE OPTIONAL G GND 0A BEN-0-[V-A-AAAX]- -000V Issued /0 00 Nordson Corporation

7 B - L L L N GROUND STACK LIST SOURCE WIRE LOCATION FRAME REAR H/G H/G TANK FRONT TOP COVER EXP. SEPLATE H/G H/G H/G H/G 00:0 TRANSFORMER COM 0 V 00 V SURGE GUARD Z F F F G G HG HG G G G G XC HG HG CONTACTOR BOARD HG HG A D D A B B D C C C D Z SURGE GUARD XC BC BB BB JC C COM COM 0V 00V D B K XSA,B,C XSA,B,C,D XSA,B XSA A JC LEVEL LEVEL LEVEL LEVEL LEVEL 00:0 TRANSFORMER SE XSH XSH / HOSE/GUN BOARD F F F F BXP BE XT AC_ TH TH 00 V TANK BOARD BK TRIGGER IN ENABLE IN XSB XSB XH XH X Y A B C D 0 XH 0 XP XP XP XP 00 V TANK HC HC GUN HG GUN BD GUN GUN XP HG G,HC,HC XP PATTERN DRIVER BOARD PARTS IN DOTTED LINES ARE OPTIONAL 0A Fig. B - Wiring Diagram for Voltage Code Units ( of ) 00 Nordson Corporation -000V Issued /0 BEN-0-[V-A-AAAX]-

8 B -. Voltage Code Wiring Diagram This wiring diagram applies to voltage code units only. Refer to Table B - to determine the voltage code of your unit. I/O BK SIGNALS PL DISPLAY BD PL TB0 & TB0 I/O BOARD J XP PC ENGINE BD XP XP XPA XP XP KEYPAD XP BOARD DIGITAL PROCESSOR XP0 XP XP XP S XP XPB Y X R 0 0 HC HC GUN HG GUN HG RS/RS COMMUNICATIONS XP HC BM BL ON/OFF XS XS J F0 F X TB K F F F F F F F F F F T TBB TBC TBD A B XP X BOARD TB WARNING FAULT NOT READY X X J XS XS J TSTAT AA PNEUMATIC SOLENOID VALVE TANK OVERTEMP THERMOSTAT 0 0 HC GUN HG GUN HG FRAME G REAR G FRONT G TOP COVER G EXPANSION SE PLATE G HOPPER COVER G0 TANK G HOSE/GUN HG HOSE/GUN HG GND 0A Fig. B - Wiring Diagram for Voltage Code Units ( of ) BEN-0-[V-A-AAAX]- -000V Issued /0 00 Nordson Corporation

9 B - 0 Vac Vdc SSRELAY CM CL INCOMING 0 Vac GROUND STACK LIST SOURCE WIRE LOCATION FRAME REAR H/G H/G TANK FRONT TOP COVER EXP. SEPLATE H/G H/G H/G H/G EXP. XFMR BRACKET 0 Vac DISTRIBUTION BOARD TB F L TBC F L TBB L T PE METAL END FRAME G G HG HG G G G G HG HG HG HG T F XD J A A A D D A B B B C C C D A J AA S R L L L L COM XFMR 0/0 0 COM F K T T T T C A XD CHASSIS 0 Vac TANK XDA D B XDB A XD LEVEL LEVEL LEVEL LEVEL + XD X Y A B C D INPUT OUTPUT G CL CM BD BK TRIGGER IN ENABLE IN BL BM HG G,HC,HC XP XP XP XH 0 F XSH F GUN XP XH F HC XSH F HG / HOSE/GUN BOARD XH 0 GUN GUN GUN XP XP PATTERN DRIVER BOARD HC Fig. B - Wiring Diagram for Voltage Code Units ( of ) 0A 00 Nordson Corporation -000V Issued /0 BEN-0-[V-A-AAAX]-

10 B - BEN-0-[V-A-AAAX]- -000V Issued /0 00 Nordson Corporation

Wiring Diagrams. Part F, Section 1. This section covers the following unit congifurations. F3EN [3V - A - AAAX] V Issued 5/00

Wiring Diagrams. Part F, Section 1. This section covers the following unit congifurations. F3EN [3V - A - AAAX] V Issued 5/00 Part F, Section Wiring Diagrams This section covers the following unit congifurations. Model All Voltage All Pump All Manifold All Control All E 000 Nordson Corporation -000V Issued /00 FEN - 0 - [V -

More information

Schematics. Part B, Section 4

Schematics. Part B, Section 4 Part B, Section This section covers the following unit congifurations. Model 0 and 0 Voltage, Pump DC Gear (O, R, S, T, U, or W) Manifold -Port (K, L, O or P) -Port (R or U) Control MultiScan 000 Nordson

More information

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3830 Voltage 1, 2 Pump AC Gear (K or L)

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3830 Voltage 1, 2 Pump AC Gear (K or L) Part B, Section This section covers the following unit congifurations. Model 0 Voltage, Pump AC Gear (K or L) Manifold -Port (J) Control MultiScan 000 Nordson Corporation -000 Issued /00 BEN-0-[M-SCHEM]-

More information

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3100, 3400 Voltage 1 Pump Piston (E or G)

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3100, 3400 Voltage 1 Pump Piston (E or G) Part B, Section This section covers the following unit congifurations. Model 00, 00 Voltage Pump Piston (E or G) Manifold -Port (A) Control MultiScan 000 Nordson Corporation -000 Issued /00 BEN-0-[M-SCHEM]-

More information

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3500 Voltage 1 Pump Piston (E, F or G) 6-Port (B or C)

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3500 Voltage 1 Pump Piston (E, F or G) 6-Port (B or C) Part B, Section This section covers the following unit congifurations. Model 00 Voltage Pump Piston (E, F or G) Manifold Control -Port (A) -Port (B or C) UniScan 000 Nordson Corporation -000 Issued /00

More information

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3100, 3400 Voltage 1, 2 Pump Piston (E or G)

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3100, 3400 Voltage 1, 2 Pump Piston (E or G) Part B, Section This section covers the following unit congifurations. Model 00, 00 Voltage, Pump Piston (E or G) Manifold -Port (A) Control MultiScan 000 Nordson Corporation -000 Issued /00 BEN-0-[M-SCHEM]-

More information

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3500 Voltage 1, 2 Pump Piston (E, F or G) 6-Port (B or C)

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3500 Voltage 1, 2 Pump Piston (E, F or G) 6-Port (B or C) Part B, Section This section covers the following unit congifurations. Model 00 Voltage, Pump Piston (E, F or G) Manifold Control -Port (A) -Port (B or C) UniScan 000 Nordson Corporation -000 Issued /00

More information

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3100 and 3400 Voltage 1, 2 Pump Piston (E or G)

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3100 and 3400 Voltage 1, 2 Pump Piston (E or G) Part B, Section This section covers the following unit congifurations. Model 00 and 00 Voltage, Pump Piston (E or G) Manifold -Port (A) Control UniiScan B -0 B - Section B. Introduction The wiring diagrams

More information

Installation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B

Installation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B Instruction Sheet P/N 1047806B Installation of Fillmaster DuraBlue Melters System on WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use

More information

Operation. Section 4. Additional Information. Operation 4-1

Operation. Section 4. Additional Information. Operation 4-1 4-1 Section 4 WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or service the equipment

More information

P/N B ProBlue and DuraBlue Thermostat Service Kit - P/N

P/N B ProBlue and DuraBlue Thermostat Service Kit - P/N P/N 1029717B ProBlue and DuraBlue Thermostat Service Kit - P/N 1028321 This instruction sheet provides separate instructions for replacing a thermostat on ProBlue and a DuraBlue adhesive melters. Tools:

More information

400/480 Volt ProBlue Adhesive Melters

400/480 Volt ProBlue Adhesive Melters E-1 Appendix E WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or service the equipment

More information

Technical Data for 3400 Melters

Technical Data for 3400 Melters Part D, Section 1 Technical Data for 300 Melters This section covers the following unit configurations. Model 300 Voltage All Pump All Manifold All Control All 1-3000 D1EN-01-[3-TD]-2 D 1-0 Technical Data

More information

Inscription Area/Color Labeling Accessories W H Order No. Price Packing Illustration Description mm mm 1 Pkg. 1 Pkg.

Inscription Area/Color Labeling Accessories W H Order No. Price Packing Illustration Description mm mm 1 Pkg. 1 Pkg. Type 8WA1 / 8WA2 Labeling Accessories Inscription Area/Color Labeling Accessories W H Order No. Price Packing Illustration Description mm mm 1 Pkg. 1 Pkg. $ Frames/Plates Labeling plates for terminal blocks,

More information

AWUF Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features

AWUF Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features Series Wall-Mount Air Handler 1½ to 3 Tons Contents Nomenclature...2 Accessories...2 Product Specifications...3 Dimensions...6 Airflow Data...8 Wiring Diagram...9 Product Features Equipped with a Check

More information

POINTAX 6000L2 Point Recorder

POINTAX 6000L2 Point Recorder GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,

More information

ProHelp Systems MIU 10X/98 WIRING / INSTALLATION INSTRUCTIONS

ProHelp Systems MIU 10X/98 WIRING / INSTALLATION INSTRUCTIONS ProHelp Systems MIU 10X/98 WIRING / INSTALLATI INSTRUCTIS 2 MIU-10X /5XS SETUP AND CFIGURATI MIU-10X Configuration and Diagnostics Screen Upon boot-up the MIU-10X first runs a self-diagnosis routine to

More information

C E R A M I C S. Mo t i f

C E R A M I C S. Mo t i f Mo t i f Mo t i f We are very pleased to introduce the lovely Motif line from Pratt & Larson. The Motif designs were created by Jennifer Plaster, one of the many talented artists that work at Pratt & Larson.

More information

Mach3 USB Motion Card (STB5100) Installation Manual

Mach3 USB Motion Card (STB5100) Installation Manual Mach3 USB Motion Card (STB5100) Installation Manual V2.1 The motion control card for machine control, with strong professional. Requires the operator to have the relevant expertise! If used improperly,

More information

Installation Manual February Model 752E Phase Selector Model 754E Phase Selector Model 760E Card Rack Model 759 Auxiliary Interface Panel

Installation Manual February Model 752E Phase Selector Model 754E Phase Selector Model 760E Card Rack Model 759 Auxiliary Interface Panel Installation Manual February 2008 Opticom Infrared System Model 752E Phase Selector Model 754E Phase Selector Model 760E Card Rack Model 759 Auxiliary Interface Panel Installation i Table of Contents 1

More information

2016 Edition V3.0 LED DRIVER PRODUCT CATALOGUE

2016 Edition V3.0 LED DRIVER PRODUCT CATALOGUE 2016 Edition V3.0 LED DRIVER PRODUCT CATALOGUE ABOUT MOSO Shenzhen MOSO Electronics Technology Co., Ltd. is a subsidiary of the MOSO Power Supply Technology Co., Ltd. A national hi-tech and energy-saving

More information

John Deere. MODEL: 116 & 116H Lawn Tractors JD-P-PC1871

John Deere. MODEL: 116 & 116H Lawn Tractors JD-P-PC1871 John Deere MODEL: 6 & 6H Lawn Tractors THIS IS A MANUAL PRODUCED BY JENSALES INC. WITHOUT THE AUTHORIZATION OF JOHN DEERE OR IT'S SUCCESSORS. JOHN DEERE AND IT'S SUCCESSORS ARE NOT RESPONSIBLE FOR THE

More information

Effective october 14, 2014

Effective october 14, 2014 MARK V XCEL & Mark V-00 XCEL ELECTRIC convection oven REPLACEMENT PARTS LIST Effective october, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event

More information

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC Properties 1 Parameters 2 Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) Manual

More information

Instruction Sheet P/N _06 5/2014

Instruction Sheet P/N _06 5/2014 Instruction Sheet P/N 1029717_06 5/2014 ProBlue, ProBlue Liberty, DuraBlue, or Mesa Thermostat Service Kit - P/N 1028321 This instruction sheet describes the procedure for replacing a manifold or tank

More information

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards The Solo, Select and Sync PWM boards provide a pulse-width modulated (PWM) signal to the EC motor to control fan speed.

More information

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV Certificate Number 20081124 E29197A Page 1 of 8 Report Reference E29197, 1974 September 17 Issue Date 2008 November 24 Issued to: This is to certify that representative samples of SIEMENS ENERGY & AUTOMATION

More information

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Earth Leakage Monitoring System IsoBase IsoHub IsoOut 2014 11 21 Earth Leakage Monitoring System IsoBase IsoHub IsoOut User Manual Due to our policy of continual improvement, specifications may change without prior notice Page 2 (34) Contents Earth Leakage

More information

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6 89 500/110 ED EWM-P-AA DIGITAL CARD FOR PRESSURE AND FORCE CONTROL IN CLOSED LOOP SYSTEMS RAIL MOUNTING TYPE: DIN EN 50022 OPERATING PRINCIPLE The EWM-P-AA has been developed for pressure closed loop control

More information

Section M. GS CONSOLIDATED ELECTRONICS and GS NEXGEN ELECTRONICS

Section M. GS CONSOLIDATED ELECTRONICS and GS NEXGEN ELECTRONICS Section M GS CONSOLIDATED ELECTRONICS and GS NEXGEN ELECTRONICS 1M Index No. Part No. Description 1. 47-862841-000 GS Consolidated Electronics High Voltage Box Assembly (includes Mount and Mounting Hardware)

More information

Brief description of KR 15 controllers

Brief description of KR 15 controllers Brief description of KR 15 controllers E N E R G Y R E C O V E R Y Page 2 Page 4 Page 5 Page 6 Page 9 1. Function of the controller 2. Terminal connections 3. Technical data 4. Initial operation 5. Manual

More information

C0330, C0530, C0630, C0830, C1030 Service Parts

C0330, C0530, C0630, C0830, C1030 Service Parts This part list contains the service parts for the air cooled, water cooled and remote air cooled C00, C00, C00, C00, C00 ice machines. There was a change to panels and the C00 air cooled condenser in late

More information

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

Optional end of travel limit switches for user setting of minimum and maximum pressure values. A M/P Converters Features (Varies with s) AC Control Unit (CC) Output pressure locks in last position in event of power failure. Continuous AC Motor unit is instant start-stop, heavy duty impedance protected

More information

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

Optional end of travel limit switches for user setting of minimum and maximum pressure values. A M/P Converters Features (Varies with s) AC Control Unit (CC) Output pressure locks in last position in event of power failure. Continuous AC Motor unit is instant start stop, heavy duty impedance protected

More information

Series 7 Power Controllers

Series 7 Power Controllers Series 7 DIN Rail Mount Power Devices Series 7 Power Devices put 12 to 80 Amps in a DIN rail mount package that provides precision machine control for heater bands, cartridge heaters, and other resistive

More information

Mark Scheme (Results) January 2011

Mark Scheme (Results) January 2011 Mark Scheme (Results) January 011 Functional Skills Functional Skills Mathematics Level (FSM0) Edexcel is one of the leading examining and awarding bodies in the UK and throughout the world. We provide

More information

Bloodhound Working Dog (16/pp) quiltartdesigns.blogspot.com

Bloodhound Working Dog (16/pp) quiltartdesigns.blogspot.com QUILT ART DESIGNS ALL QUILT ART PATTERNS ARE FOR PRIVATE USE ONLY. Bloodhound Working Dog (6/pp) Quilt Art Designs 06 quiltartdesigns.blogspot.com quiltartdesigns.blogspot.com QUILT ART DESIGNS Tips: Shorten

More information

Microprocessor Control Board Set Up Procedures (OR PLC)

Microprocessor Control Board Set Up Procedures (OR PLC) Microprocessor Control Board Set Up Procedures (OR-00 PLC) SWITCHES/PUSHBUTTONS Push Buttons at display SW Enter button SW Back button SW Down SW UP Back light on/off switch Rotary switches on main board

More information

Model 2400 Explosion-Proof M/P Converters -- LOCK IN LAST POSITION --

Model 2400 Explosion-Proof M/P Converters -- LOCK IN LAST POSITION -- A Explosion-Proof M/P Converters -- LOCK IN LAST POSITION -- Electrical AC Control Unit Motor Voltage...115vAC, 60Hz Power Consumption (watts) 10 Regulator...5(Max.) 16 Regulator...3(Max.) 80 Regulator...3(Max.)

More information

DPC-100VO. Proportional Voltage Controller. Features. Applications

DPC-100VO. Proportional Voltage Controller. Features. Applications DPC-100VO Features Main Dec. Microprocessor Controlled Voltage Generator 0-10 V 0-5 V Min. Max. Ground Precision Digital Circuit Replaces Potentiometer Works in 12- or 24-Volt Systems Adjustable Minimum/Maximum

More information

RODIX INCORPORATED rd Ave., ROCKFORD IL TOLL FREE (800) , FAX (815)

RODIX INCORPORATED rd Ave., ROCKFORD IL TOLL FREE (800) , FAX (815) FEEDER CUBE CE43 Plus General Purpose OIL RESISTANT MODEL IMPORTANT: APPLICATION NOTE RODIX INCORPORATED 2316 23 rd Ave., ROCKFORD IL 61104 TOLL FREE (800) 5621868, FAX (815) 3164701 Email custserve@rodix.com

More information

Blue Point Engineering

Blue Point Engineering Blue Point Engineering Instruction I www.bpesolutions.com Pointing the Way to Solutions! Puppet - II+ Controller (BPE No. PCA-0001) Servo Position Adjustment EEPROM Digital Button Power 5 Vdc Playback

More information

DIGITAL FEEDER CONTROL

DIGITAL FEEDER CONTROL CONTROL Version - March 010 For Software Version V3.16 For Digital Control Part Numbers 06-080 - 1/4vDC Switching Positive 06-085 - 1/4vDC Switching Negative or 1/4vAC Part Number - 39-0050 CONTROL: INDEX

More information

PACSystems* RX3i and Series 90-30

PACSystems* RX3i and Series 90-30 May 2012 PACSystems* RX3i and Series 90-30 Series 90*-30 Analog Output Module, Current/Voltage, 8 Channel, IC693ALG392 RX3i Analog Output Module, Current/Voltage, 8 Channel, IC694ALG392 The PACSystems

More information

8WD4 Signaling Columns

8WD4 Signaling Columns Siemens AG 200 General data Overview The 8WD4 signaling columns are flexible in design and versatile in use. 1 1 2 2 3 3 4 5 4 6 8 5 6 10 11 8 12 15 13 14 10 NSC0_002 11 12 NSC0_0026 1 Acoustic element

More information

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES PEAKTRONICS The Peaktronics AC Motor Interface is used to interface common electrical control signals to AC actuators. The unit provides the motor drive circuits, protection circuits, and isolation between

More information

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual IM-LZSA500-3 January 2008 Revision H Table of Contents LZS-A500-3 Power Supply 1) Safety and Recommended Practices 2 1.1 General

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS PRODUCTS CCM SERIES NOTE: This document provides the necessary information for the use and operation of Greystone current valves. Greystone Energy Systems Inc. reserves

More information

SC30-SM2 Series Signal Conditioners

SC30-SM2 Series Signal Conditioners Read these instructions carefully and completely before installing or operating. Failure to follow them could result in a fire or explosion causing property damage, personal injury, or loss of life. The

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series 5 Individual mounting Series Inline Bonded spool Air return Manual operator Solenoid 4-way pilot with balanced poppet 33 34 36 3 37 38 5 67 69

More information

Field Network SRT Series

Field Network SRT Series Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Field Network SRT Series

More information

Section M. GS CONSOLIDATED ELECTRONICS and GS NEXGEN ELECTRONICS

Section M. GS CONSOLIDATED ELECTRONICS and GS NEXGEN ELECTRONICS Section M GS CONSOLIDATED ELECTRONICS and GS NEXGEN ELECTRONICS December 2009 1M Index No. Part No. Description 1. 47-862841-000 N.A. GS Consolidated Electronics High Voltage Box Assembly (includes Mount

More information

Current Loop Interface Module M-2025C

Current Loop Interface Module M-2025C CONTROLS Interface Module M-2025C Current-to-Voltage Analog Converter used with the M-2001 Series Digital Tapchanger Control and M-2948/M-2949 Tap Position Sensors to provide positive tap position knowledge

More information

DX450 Red-D-Arc PARTS LIST FOR RETURN TO MAIN INDEX

DX450 Red-D-Arc PARTS LIST FOR RETURN TO MAIN INDEX Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-582 RETURN TO MAIN INDEX PARTS LIST FOR DX450 Red-D-Arc P-582 Index of Sub

More information

C E R A M I C S. Motif

C E R A M I C S. Motif Motif Motif The Motif designs were created by Jennifer Plaster, one of the many talented artists that work at Pratt & Larson. These stunning new designs were influenced by the traditional Cuenca technique

More information

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs Photoelectrics, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs µ-processor controlled unit for up to 10 sets of photoelectric sensors Up to 10 independent outputs Self-diagnostic

More information

Blue Point Engineering

Blue Point Engineering DMX -Channel Relay Board Overview A two-channel DMX relay switch for switching loads up to 0A at 40V AC per channel. he DMX switch operates on the standard DMX5 bus and requires - DMX channels for operation.

More information

Chapter 1. Chapter 2. STS Setup. Chapter 3. Decoder. Chapter 4. ICC Setup. Appendix A - B -

Chapter 1. Chapter 2. STS Setup. Chapter 3. Decoder. Chapter 4. ICC Setup. Appendix A - B - 1 Mottech 2 Wire AC Decoder Owner s Manual 2 Contents Chapter 1 Chapter 2 Chapter 3 Chapter 4 - - - - Install and wire the "254 2W" module STS Setup Decoder Programming and Setup ICC Setup Appendix A -

More information

REIMESCH KOMMUNIKATIONSSYSTEME GMBH ALPIN HF / 50MHz Linear Amplifier - USER MANUAL. v1.1

REIMESCH KOMMUNIKATIONSSYSTEME GMBH ALPIN HF / 50MHz Linear Amplifier - USER MANUAL. v1.1 REIMESCH KOMMUNIKATIONSSYSTEME GMBH ALPIN 100 - HF / 50MHz Linear Amplifier - USER MANUAL v1.1 DECLARATION OF CONFORMITY I hereby declare that the product: ALPIN 100, HF/6m 1kW Linear Amplifier satisfies

More information

Flickerless / Dim Power supply

Flickerless / Dim Power supply Model Name : Features : ㅡ Flickerless ㅡ Full-protection provided: OCP/OVP/OTP/SCP/OLP ㅡ Low Power Dissipation (Stand-by mode :

More information

Flickerless / Dim Power supply

Flickerless / Dim Power supply Model Name : Features : ㅡ Flickerless ㅡ Full-protection provided: OCP/OVP/OTP/SCP/OLP ㅡ Low Power Dissipation (Stand-by mode :

More information

Red: PAINTED ITEMS Blue: KITS IPDA2

Red: PAINTED ITEMS Blue: KITS IPDA2 Number QTY. DESCRIPTION 73-785 8 SCREW, MX0.7,MM, CPS, CS, BO 73-873 BRKT,DUAL PULLEY Number QTY. DESCRIPTION 7-0 6 PLASTIC,COVER,ACCESSORY RACK 0-93 BOLT M X.75, 30MM HHC HE CS ZP 03-5 3/8" Jam Nut 0-50

More information

ROCKER SWITCHES B 1 SERIES 3A SPECIFICATIONS AGENCY APPROVALS

ROCKER SWITCHES B 1 SERIES 3A SPECIFICATIONS AGENCY APPROVALS Miniature Rocker & Paddle switches HOW TO ORDER AGENCY APPROVALS C File N E195524 File N E195524 CHARACTERISTICS The most comprehensive range of terminations, brackets, toggle sizes and bushings. Dially

More information

Wiring Instructions for 10, 16 & 20 Function, 92 & 93 Series, FET Receivers.

Wiring Instructions for 10, 16 & 20 Function, 92 & 93 Series, FET Receivers. Wiring Instructions for 10, 16 & 20 Function, 92 & 93 Series, FET Receivers. 92220.02E 1 1. The Receiver is designed to carry a maximum of 15 Amps. That is, for example,15 Amps through one output or 5

More information

PARTS LIST ELECTRIC BOILERS MODELS: CE24 CE36 CE42 CE48 CE324 CE336 CE342 CE348

PARTS LIST ELECTRIC BOILERS MODELS: CE24 CE36 CE42 CE48 CE324 CE336 CE342 CE348 PARTS LIST ELECTRIC BOILERS MODELS: CE24 CE36 CE42 CE48 CE324 CE336 CE342 CE348 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358,

More information

Level Limit Switch nivotester FTL 325 P

Level Limit Switch nivotester FTL 325 P Technical Information TI 350F/24/ae Level Limit Switch nivotester FTL 325 P With intrinsically safe signal circuit for connection to the Liquiphant and Soliphant measuring sensor Application Level limit

More information

S-band 500kW Magnetron

S-band 500kW Magnetron S-band 500kW Magnetron GENERAL DESCRIPTION M1901A is a mechanically tunable frequency pulsed type S-band magnetron designed to operate in the frequency range of 2.7 GHz to 2.9 GHz with a peak output power

More information

RODIX INCORPORATED rd Ave., ROCKFORD IL TOLL FREE (800) , FAX (815)

RODIX INCORPORATED rd Ave., ROCKFORD IL TOLL FREE (800) , FAX (815) RODIX INCORPORATED 2316 23 rd Ave., ROCKFORD IL 61104 TOLL FREE (800) 5621868, FAX (815) 3164701 Email custserve@rodix.com www.rodix.com FEEDER CUBE CE44240 Plus ALL PURPOSE OIL RESISTANT MODEL IMPORTANT:

More information

MATHCOUNTS. 100 Classroom Lessons. August Prepared by

MATHCOUNTS. 100 Classroom Lessons. August Prepared by MATHCOUNTS 100 Classroom Lessons August 2000 Prepared by John Cocharo The Oakridge School 5900 W. Pioneer Parkway Arlington, TX 76013 (817) 451-4994 (school) jcocharo@esc11.net (school) cocharo@hotmail.com

More information

UII Pump Parts

UII Pump Parts 0-4-0-4-UII Pump Parts. Page 66 95-0305 September 009 Parts Lists 0-4-0-4-UII Pump Parts QTY. PER PUMP PART NOTES 0-U Pump Body See Note 0-U Pump Body with Flush See Note 4-U Pump Body See Note 4-U Pump

More information

DPC-100LC. Proportional Valve Driver. Features. Applications

DPC-100LC. Proportional Valve Driver. Features. Applications DPC-100LC Features +Power True Current-Regulated Flow Control Auto-Configures for 12- or 24-Volt Systems Adjustable Minimum/Maximum Current: 12 V: User-selectable 0 0.50 A or 0 0.75 A 24 V: User-selectable

More information

Glim Cube iguzzini. design Piero Castiglioni SPECIFIC LIGHTING EFFECT LUMINAIRES. Easy maintenance (lamps have longer life)

Glim Cube iguzzini. design Piero Castiglioni SPECIFIC LIGHTING EFFECT LUMINAIRES. Easy maintenance (lamps have longer life) Wall-mounted luminaire for lighting effects equipped with LED sources. Composed of diffuser and support base. Polymetacrylic striped screen, die-cast aluminium support base (made of Zama 5 for single versions),

More information

Features. Introduction. Applications. Ordering Information

Features. Introduction. Applications. Ordering Information 80/809/80-8/8/-8/8/8-6/6/6/6 Features Precision supply-voltage monitor -.6V (8xxL, 6xL) -.8V (8xxM, 6xM) -.08V (8xxT, 6xT) -.9V (8xxS, 6xS) -.6V (8xxR, 6xR) -.V (8xxZ, 6xZ) -.0V (8xxY, 6xY) 00ms reset

More information

TENTATIVE PP800D120-V01

TENTATIVE PP800D120-V01 Description: The Powerex POW-R-PAK is a configurable IGBT based power assembly that may be used as a converter, chopper, half or full bridge, or three phase inverter for motor control, power supply, UPS

More information

GB/GW GB/GW GB/GW GB/GW

GB/GW GB/GW GB/GW GB/GW GAS-FIRED COMMERCIAL REPLACEMENT PARTS LIST COPPER BOILERS FOR HYDRONIC HEATING & HOT WATER SUPPLY MODELS : 1000, 1300, 1500, 1850, 2100, 2500 SERIES: 400-405 A.O. SMITH WATER PRODUCTS COMPANY 500 TENNESSEE

More information

USER MANUAL LDY CW Diode Driver Power Supplies

USER MANUAL LDY CW Diode Driver Power Supplies USER MANUAL LDY CW Diode Driver Power Supplies The LDY family of CW diode laser drivers is Lumina Power s second generation of high power laser diode drivers. As a laser diode driver, the LDY power supply

More information

THT TYPE. Interface unit with built-in DO module FEATURES

THT TYPE. Interface unit with built-in DO module FEATURES INTERFACE UNIT THT TYPE FEATURES Both and DO modules of the THT type interface unit have the same structure, providing a smart appearance. The connector sockets and operation indicators are located at

More information

M1014 7" x 12" Metal Cutting Bandsaw PARTS -38-

M1014 7 x 12 Metal Cutting Bandsaw PARTS -38- 14 13 15 16 18 17 55 10 12 11 19 54 9 20 53 7 5 4 60 7 3 1 28 6 2 61 23 27 26 29 21 24 25 22 32 32 33 35 36 37 38 49 48 47 40 39 34 30 59 51 52 46 45 44 43 42 42 41 50 56 57 58-38- Parts List 1 XM1014001

More information

** Do Not Contact the Store ** For Assistance, including missing or broken parts, Call Customer Service at:

** Do Not Contact the Store ** For Assistance, including missing or broken parts, Call Customer Service at: 3/01/2007 VISIT THE LITIME WEB SITE: WWW.LITIME.COM ** Do Not Contact the Store ** For Assistance, including missing or broken parts, Call Customer Service at: 1 (800) 225-3865 Double Shed Doors for Back

More information

A.O. SMITH WATER PRODUCTS COMPANY 5621 W. 115TH STREET ALSIP, ILLINOIS Phone: Fax:

A.O. SMITH WATER PRODUCTS COMPANY 5621 W. 115TH STREET ALSIP, ILLINOIS Phone: Fax: PSD-3-158 GAS-FIRED COMMERCIAL REPLACEMENT PARTS LIST COPPER BOILERS FOR HYDRONIC HEATING & HOT WATER SUPPLY MODELS : 300, 400, 500, 650, 750 SERIES: 300, 301, 302, 303 2-STAGE UNITS A.O. SMITH WATER PRODUCTS

More information

3TK28 Safety Relays. General data. 7/70 Siemens LV

3TK28 Safety Relays. General data. 7/70 Siemens LV 3TK28 Safety Relays General data Overview SIRIUS safety relays are the key elements of a consistent and cost-effective safety chain. Be it EMERGENCY-STOP disconnection, protective door monitoring or the

More information

TECHNICAl PWLICATION MANUAL TIME INTERVAL CONTROL MODEL CT-12. ISSUED 9m. Publication No P&A Division SUPERSEDES

TECHNICAl PWLICATION MANUAL TIME INTERVAL CONTROL MODEL CT-12. ISSUED 9m. Publication No P&A Division SUPERSEDES ed5 Atlanta, Georgia TECHNICAl PWLICATION 57-2o-o MANUAL 57-20 TIME INTERVAL CONTROL MODEL CT-12 ISSUED 9m 0 NORDSON CORPORATION 1986 0 Nordson Atlanta, Georgia TECHNICAL PUBLICATION 57-20-01 Table of

More information

Horizontal Band Saw. Operating Instructions and Parts Manual. Models EHB-1018VM EHB-1018VMH

Horizontal Band Saw. Operating Instructions and Parts Manual. Models EHB-1018VM EHB-1018VMH Operating Instructions and Parts Manual Horizontal Band Saw Models EHB-08VM EHB-08VMH JET 427 New Sanford Road LaVergne, Tennessee 37086 www.jettools.com Ph.: 855-336-4032 Part No. M-89070 REV B2 08/204

More information

WC 1 WELD SEQUENCE CONTROLLER. Operation / Installation Manual Manual Part Number: C8M5002 Date: July 9, 2002 Revised: July 24, 2003

WC 1 WELD SEQUENCE CONTROLLER. Operation / Installation Manual Manual Part Number: C8M5002 Date: July 9, 2002 Revised: July 24, 2003 2200 Corporate Drive Troy, OH 45373 Phone: (937) 440-000 Fax: (937) 440-0277 WC WELD SEQUENCE CONTROLLER Operation / Installation Manual Manual Part Number: C8M5002 Date: July 9, 2002 Revised: July 24,

More information

Installation Instructions for CMS Pro Meter (with Breakout Box Type-A) for Yamaha V-Max 1700

Installation Instructions for CMS Pro Meter (with Breakout Box Type-A) for Yamaha V-Max 1700 Installation Instructions for CMS Pro Meter (with Breakout Box Type-A) for Yamaha V-Max 1700 Notes: (1) For the remainder of this document, Meter is referring to the Motoscope Pro Meter which comes with

More information

Instructions MODIFICATION KIT MODEL SBM - 1O2-1 INTRODUCTION PARTS LIST FOR THE

Instructions MODIFICATION KIT MODEL SBM - 1O2-1 INTRODUCTION PARTS LIST FOR THE Instructions FOR THE MODIFICATION KIT MODEL SBM - 1O2-1 INTRODUCTION This modification Kit applies to the following Heath Transceivers: 1. All Models HW-100, SB-100, SB-101 and SB-101W. 2. Any Model SB-102

More information

BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG

BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG PRODUCT CATALOG M O T O R & G E N E R A T O R P R O T E C T I O N BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG Why Your Equipment Needs MEG-ALERT Protection 1 2 3 4 5 6 7 How can you be sure

More information

Application Solutions for: Analog (Input /

Application Solutions for: Analog (Input / Application Solutions for: Analog (Input / Output), Pneumatic (Input / Output), Pulse (Input / Output), Resistive (Input / Output), Floating Point (Input / Output), DDC Control, Compressor Staging, Chiller

More information

Blue Point Engineering

Blue Point Engineering Blue Point Engineering Instruction I www.bpesolutions.com Pointing the Way to Solutions! Animatronic Wizard - 3 Board (BPE No. WAC-0030) Version 3.0 2009 Controller Page 1 The Wizard 3 Board will record

More information

Flickerless / Dim Power supply

Flickerless / Dim Power supply Model Name : Features : ㅡ Flickerless ㅡ Fullprotection provided: OCP/OVP/OTP/SCP/OLP ㅡ Low Power Dissipation (Standby mode :

More information

PAM & SAM System User s Manual

PAM & SAM System User s Manual PAM & SAM System User s Manual Part 5 - SAM Drive Technical Information Ordering Number: 9032 011 985 Issue November 14, 2000 This version replaces all previous versions of this document. It also replaces

More information

Impulse system MPT 700. Manual Edition GB

Impulse system MPT 700. Manual Edition GB Impulse system MPT 700 Manual 6.2.2.2 Edition 10.10 GB 1 Introduction... 4 1.1 Version and model... 5 1.2 CE Mark... 7 2 Operation... 8 2.1 Controls... 8 2.1.1 Front panel... 8 2.1.2 Parameter display...

More information

USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast

USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast 26 Ward Hill Dr., Bradford, MA 01835 Phone: +1-978-241-8260 Fax: +1-978-241-8262 USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast The XLB-650 Xenon lamp ballast is a very compact power supply designed

More information

Outdoor. PISE-A150D (Pb-Free) 150W Output Power with DALI. Features. Critical Specifications. Input Specifications. Output Specifications IP66

Outdoor. PISE-A150D (Pb-Free) 150W Output Power with DALI. Features. Critical Specifications. Input Specifications. Output Specifications IP66 PISE-A150D (Pb-Free) 150W Output Power with DALI 125V - 280V / 0.35A - 0.7A / 150W Features Dimming Method : 1-10 Dim, DALI, Schedule Dimmer Input Cable : Double or Reinforced Insulation Mechanical Outline

More information

Programmable AC Power Source Model 9801

Programmable AC Power Source Model 9801 Data Sheet Programmable AC Power Source The 9801 is both a programmable AC power source and measurement tool in a compact benchtop package. This fully programmable linear AC source delivers up to 300 VA

More information

V6300 V6301. Ultra Low Power 3-Pin Power-On Reset IC. Features. Description. Applications. Microprocessor V6300/01 RES

V6300 V6301. Ultra Low Power 3-Pin Power-On Reset IC. Features. Description. Applications. Microprocessor V6300/01 RES EM MICROELECTRONIC - MARIN SA Ultra Low Power 3-Pin Power-On Reset IC Description The and are CMOS devices which monitor the supply voltage of any electronic system, and generate the appropriate Reset

More information

C0330, C0530, C0630, C0830, C1030 Service Parts

C0330, C0530, C0630, C0830, C1030 Service Parts This part list contains the service parts for the air cooled, water cooled and remote air cooled C00, C00, C00, C080, C00 ice machines. To avoid costly and time consuming errors, double check the model

More information

FEATURES DESCRIPTION THE OEM ADVANTAGE

FEATURES DESCRIPTION THE OEM ADVANTAGE FEATURES PMAC2 controller from Delta-Tau controls amp bridge directly MODEL POWER I-CONT (A) I-PEAK (A) 7229AC 32~132VAC 10 20 7429AC 32~264VAC 10 20 Serial digital current feedback from U & V phases Mini

More information

RTD-Style Special e.dot Hot Melt Hoses

RTD-Style Special e.dot Hot Melt Hoses User s Guide P/N 1081164A 02 RTD-Style Special e.dot Hot Melt Hoses Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection or seal. Failure to relieve

More information

Experiment No. 6 Output Characteristic of Transistor

Experiment No. 6 Output Characteristic of Transistor Experiment No. 6 Output Characteristic of Transistor Object: To examine the output characteristic of transistor. Apparatus: 1. Two DC power supply. 2. Three AVOmeters. 3. Transistor 2N2222, Resistor 1

More information