TECHNICAl PWLICATION MANUAL TIME INTERVAL CONTROL MODEL CT-12. ISSUED 9m. Publication No P&A Division SUPERSEDES
|
|
- Ferdinand Bailey
- 5 years ago
- Views:
Transcription
1 ed5 Atlanta, Georgia TECHNICAl PWLICATION 57-2o-o MANUAL TIME INTERVAL CONTROL MODEL CT-12 ISSUED 9m 0 NORDSON CORPORATION 1986
2
3 0 Nordson Atlanta, Georgia TECHNICAL PUBLICATION Table of Contents Page Safety Summary l-l Functional Description l Timer Dimensions Parts List Installation Wiring Diagram Wiring Schematic Start Up and Initial Operation ISSUED NORDSON CORPORATION 1986
4
5 0 Notdson Atlanta, Georgia TECHNICA PUB1 /CATION 5-2o - CT-12 TIME INTERVAL CONTROL Description The Nordson CT-12 Time Interval Control is a versatile, solid-state timing device for use in SWF conversions and other packaging operations requiring three channels. The CT-12 is equipped with six individual timers. These timers control three delay and three duration intervals which produce up to three beads of adjustable length and position on the substrate. \ 3 CHANNEL I CWANWL 2 CHANNEL 3 Front Panel of the CT-12 Cabinet CT.12 ON-1 TIME INTI!RVAL COWTROL cb--- /o IIWYIC O. T 2.voc. 3. OUTPUT fiyj 5/- RESET Off-0 L\ OJ m m A Trigger light (1) indicates the presence of a trigger signal. (In the Break Light mode, this light will be on except in the presence of a trigger signal.) The Output light (2) indicates when output power is being switched to the gun solenoid(s). Six ten-turn potentiometers (3) control three Delay and three Duration intervals. Channel 1, Channel 2 and Channel 3 lights (4) indicate which duration interval is in progress. m The Reset button (5) is the circuit breaker protection for the CT-12. m Power On/Off switch and indicator light (6) ISSUED 9/g4 a NORDSON CORPORATION 1986
6 Nordson Atlanta, Georgia TECHNICAL PUB1 /CAT/ON Timer Dimensions A. 10 in. (254 mm) B. 10 in. (254 mm) C. 6 in. (152 mm) D. 8 in. (203 mm) E in. (273 mm) Parts List Part No. Description Q~Y CT-12 Timer, 115 VAC Circuit Board 1 ISSUED NORDSON CORPORATION 1986
7 0 Nordson Trigger Installation Atlanta, Georgia TECHNICAL PUBLICATION The CT-12 will accept a solid-state current sinking input from a photodetector or proximity switch. A mechanical switch can be used also. Installation is as follows. 7 7 MAKELIQHT MOOE 6 BREAKLIWT MODE (N.O. SWITCH) 5 04.C. SWITCH) COMMON TRIGGER PHOTODETECTOR OR PROXIMITY SWITCH -I (6--r 2 4 TBl 1 TBl 1 TBl For electrical installation to TB2, see Figure 1. 24Vdc Gun Output The CT-12 can drive nine 8-ewatt solenoids (which are used on H20 guns), three 241-watt solenoids or two electric guns. Multiple guns or solenoids must be wired in parallel, as shown below. 8 For proper operation of the CT-12 Timer, use solenoids rated for 24Vdc only. GUN SOLENOIDS TBl ISSUED 9/86 0 NORDSON CORPORATION 1986
8 Notdson Atlanta, Georgia r d r: _--v I w 2 s,d I) -,-.&: N ;. m _ X,---. I ow -, P ;; - \ d.- _I 5 kl 4 w I I :s _- ----I- -_----- Figure 1. Wiring Diagram ISSUED g/86 0 NORDSON CORPORATION 1986
9 0 Notdson Atlanta, Georgia TECHNICAL PUBlICATlON 57-2o-5 ii ii -- Y r w 0 Figure 2. Wiring Schematic ISSUED NORDSON CORPORATION 1986
10 Nordson Atlanta, Georgia TECHNICAL PUBLICATlON Start Up and Initial Operation 1. Set the potentiometers as indicated below: Delay 1: 3 Duration 1: 3 Delay 2: 0 Duration 2: 0 Delay 3: 0 Duration 3: 0 2. Select timer interval range by following the steps below. a. Turn power off. Failure to disconnect and lockout input power to the CT-12 could result in serious electrical shock or equipment damage. b. Open the cabinet door and locate the range selection switches (see Figure 3). C. Set S8 to either Break Light or Make Light mode, depending on input trigger source. d. Set Sl, S2, S3, S4, 55 and S6 range switches to high position (5-100 ms). Each of these switches controls the range for one of the six delay or duration intervals. e. Set Channel 3 Disable switch (S7) to On for three beads or Off for two beads. If only one bead is required, set Channel 2 range switches to high position and Channel 2 pots to zero. f. Close the cabinet door and restore input power to the timer. Figure 3. Range Selection Switches ISSUED 9/86,c NORDSON CORPORATION 1986
11 0 Nordson A t/an ta, Georgia TECHNICAL PUBLICATION Start the line and adjust it to final running speed. 4. Allow several sample substrates to pass the guns. Stop the line and examine the placement of the first bead to determine what adjustments are necessary (see Figure 4), To move the bead closer to the leading edge of the substrate, decrease the setting on the Delay 1 potentiometer. To move the bead further away from the leading edge, increase the setting. Figure 4. Delay/Duration Intervals I,- Start of Bead Controlled by DELAY 3 by DELAY 2 f Length of Bead Controlled by DURATION 3 \ Length of Bead Controlled by f DURATION 2 v Direction of Travel --Start of Bead Controlled by DELAY 1 ) Length of Bead Controlled by f DURATION 1 Leading Edge Adjust the length of the bead by increasing or decreasing the setting on the Duration 1 potentiometer. Increasing the setting increases the length of the bead, decreasing the setting shortens it. If the dial on either of the potentiometers reaches its maximum setting before the desired bead or gap length is reached, reset the range selection switch. a. Turn power off. Failure to disconnect and lockout input power to the CT-12 could result in serious electrical shock or equipment damage. /SSUED $318 6 LITHO U.S.A, G NORDSON CORPORATION 1986
12 Nordson Atlanta, Georgia TECHNICAl PUBLICATION b. Open the cabinet door and set the corresponding channel range switch to the low position (100 ms-2.1-s). Adjust the placement and length of each of the remaining beads by setting the controlling delay and duration potentiometers to the same values as were established for the Delay 1 and Duration 1 potentiometers in the previous step. Increase or decrease the settings on the potentiometers as necessary to adjust the placement and length of the remaining beads. When the overall bead pattern is correct, the timer requires no further adjustment as long as line speed remains the same. The potentiometer settings must be readjusted any time line speed is changed or drifts far enough to affect bead placement significantly. ISSUED 9186 Z NORDSON CORPORATION 1986
Time Interval Control
Time Interval Control Model CT-7-2 Part 104 497A NORDSON CORPORATION AMHERST, OHIO. USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence
More informationHot Stitch Control. Model CST-1. Part A NORDSON CORPORATION. AMHERST, OHIO. USA
Hot Stitch Control Model CST-1 Part 104 494A NORDSON CORPORATION. AMHERST, OHIO. USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence
More informationInstallation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B
Instruction Sheet P/N 1047806B Installation of Fillmaster DuraBlue Melters System on WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use
More informationCBCT TM CIRCUIT BREAKER COIL TESTER
CBCT TM CIRCUIT BREAKER COIL TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 August 2010 Revision 1 SAFETY
More informationTimers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -
Key features: True power OFF-delay up to minutes No external control switch necessary Available with reset inputs Mountable in sockets or flush panel Specifications Operation UL, c-ul Listed File No. E55996
More informationDigital Interface Card DEC005000
Engineering & Manufacturing Solutions Digital Interface Card DEC005000 APPLICATION: The DEC005000 conveniently interfaces industry standard signals 4-20mA, 0-5V or 0-10V with a proportional solenoid valve
More informationProximity-Sensor Counter Installation Instruction Model: MRC-PRO
Proximity-Sensor Counter Installation Instruction Model: MRC-PRO NYS DOT Approval SYSDYNE CORP. 1055 Summer St. 1 st Floor Stamford, CT 06905 Tel: (203)327-3649 Fax: (203)325-3600 Contents: Introduction...
More informationMicroprocessor Control Board Set Up Procedures (OR PLC)
Microprocessor Control Board Set Up Procedures (OR-00 PLC) SWITCHES/PUSHBUTTONS Push Buttons at display SW Enter button SW Back button SW Down SW UP Back light on/off switch Rotary switches on main board
More informationSPECIFICATION, CONTROLS AND ACCESSORIES
AS540 Automatic Voltage Regulator (AVR) SPECIFICATION, CONTROLS AND ACCESSORIES English Original Instructions A054N491 (Issue 1) Table of Contents 1. DESCRIPTION... 1 2. SPECIFICATION... 3 3. CONTROLS...
More informationPEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES
PEAKTRONICS The Peaktronics AC Motor Interface is used to interface common electrical control signals to AC actuators. The unit provides the motor drive circuits, protection circuits, and isolation between
More informationD3000 Installation Guide
D3000 Installation Guide Safety Always wear personal protective equipment such as gloves and safety glasses when working with potentially hazardous chemicals. Electrical installation must be performed
More informationPRODUCT / TEST MANUAL 2V162K4 VOLTAGE REGULATOR RELAY
Sheet 1 of 12 TEST DATE CUSTOMER SERIAL No OLTC ACKNOWLEDGE SETUP AUTOMATIC or FEEDBACK CONTROL PRODUCT / TEST MANUAL 2V162K4 VOLTAGE REGULATOR RELAY Issue Date Level I 21/05/1998 Initial issue. Summary
More informationA NEW GENERATION PROGRAMMABLE PHASE/AMPLITUDE MEASUREMENT RECEIVER
GENERAL A NEW GENERATION PROGRAMMABLE PHASE/AMPLITUDE MEASUREMENT RECEIVER by Charles H. Currie Scientific-Atlanta, Inc. 3845 Pleasantdale Road Atlanta, Georgia 30340 A new generation programmable, phase-amplitude
More informationSchematics. Part B, Section 4. This section covers the following unit congifurations. Model 3500 Voltage 1 Pump Piston (E, F or G) 6-Port (B or C)
Part B, Section This section covers the following unit congifurations. Model 00 Voltage Pump Piston (E, F or G) Manifold Control -Port (A) -Port (B or C) UniScan 000 Nordson Corporation -000 Issued /00
More informationDDC Series Dial Digital Controller INSTALLATION AND OPERATING INSTRUCTIONS
DDC Series Dial Digital Controller INSTALLATION AND OPERATING INSTRUCTIONS Thank you for choosing the Toro DDC (Digital Dial Controller) irrigation controller. The DDC incorporates the lates programming
More informationTo Purchase This Game, Visit BMI Gaming Or Contact International Sales at (USA) The Simpsons Soccer
The Simpsons Soccer STANDARD OPERATING MANUAL Rev. 9-4-12 (Software Version: 07-30-12) Coastal Amusements, Inc. 1950 Swarthmore Ave. Lakewood, NJ 08701 +1 (732) 905-6662 sales@coastalamusements.com http://www.coastalamusements.com
More informationProgrammable timer with LVD
Programmable timer with LVD Installation Instructions Operating Instructions Espar Heater Systems Espar Products, Inc. (800) 387-4800 (905) 670-0960 www.espar.com Programmable timer with LVD 25 2800 70
More informationProgramming Parameter Guide
Secure Wireless Microphone ELITE PRO Programming Parameter Guide rev:1 How to use Programmer: Start Programming application Runs On PC or Mac running Windows 7/10. To put Handset into programming mode,
More informationOWNERS MANUAL FOR STERLING SERIES CONTROLLERS
OWNERS MANUAL FOR STERLING SERIES CONTROLLERS 24950 AVENUE KEARNY, VALENCIA, CALIFORNIA 91355-2142 PHONE (661) 257-3533 FAX (661) 257-9472 TABLE OF CONTENTS Selecting the Location for the Controller...3
More informationElectronic timers CT-S range Selection and ordering details
CT-S range Selection and ordering details Characteristics CT-S range CT-MFS 1SVR 430 010 F 0200 3 multifunction and 21 multi-range Continuous supply voltage range (24-240VAC/DC) or multisupply voltage
More informationBC145 SIGNAL ISOLATOR BOARD
BC145 SIGNAL ISOLATOR BOARD 4/17 Installation & Operating Manual MN1373 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com to download
More informationUsing the VR448 in place of the Marathon DVR 2000
Using the 448 in place of the Marathon D 2000 D2000E (digital A) provides 7.5A 150VDC Max output short time in compareson to model EA448 (Analog A) thats provide 10 A 160VDC Max output short time Both
More informationP&A Division Atlanta, Georgia TECHNICAL PUBLICATION ( )42 * SECTION VI ILLUSTRATED PARTS LIST
Nordson Atlanta, Georgia TECHNICAL PUBLICATION ( ) * SECTION VI ILLUSTRATED PARTS LIST lg COLUMN IDENTIFICATION The Item No. column indicates the number assigned to the part in the associated figure. A
More informationHitachi P1 Closed Loop Hoist Basic Instruc on Manual
Hitachi P1 Closed Loop Hoist Basic Instruc on Manual DH Firmware V.18 DETROIT HOIST AND CRANE LLC, CO. 6650 STERLING DRIVE NORTH STERLING HEIGHTS MICHIGAN 48312 Introduction This manual only applies to
More informationEIB/KNX Switch Actuators. User manual
EIB/KNX Switch Actuators User manual IT KNT 004 IT KNT 012 Tel.: +34943627988 E-mail: knx@dinuy.com Web: www.dinuy.com Contents 1. Introduction --------------------------------------------------------------------------------------------------------------
More informationModel 3102D 0-2 kv H.V. Power Supply
Features Compact single width NIM package Regulated up to ±2000 V dc. 1 ma output Noise and ripple 3 mv peak to peak Overload and short circuit protected Overload, inhibit and polarity status indicators
More informationMNM Motor Operator Installation and Operation Instructions
I. INTRODUCTION TO SEECO MNM MOTOR OPERATORS Thank you for purchasing a SEECO motor operator. We are excited to be able to provide this product to you and we are certain that it will fulfill your performance
More informationEscapeKeeper & EscapeKeeper JR
EscapeKeeper & EscapeKeeper JR OPERATING MANUAL 877-815-5744 or 905-803-9274 www.frightideas.com Contents Getting Familiar with your EscapeKeeper...4 Connections and Controls... 4 Your Current Firmware
More informationCommercial Microwave Technical Information. CAUTION All safety information must be followed as provided in Service Manual
Commercial Microwave Technical Information 0 V, 0 Hz Models RCS0MPA P00M RCS0A P00M RCS0PBDA P00M RCS0MPSA P00M RFSMPSA P00M RFSSWA P00M RCS0SWA P0M RCS0MPA P0M Due to possibility of personal injury or
More informationIndependent Technology Service Inc Independence Ave. Chatsworth, California Toll Free:
Independent Technology Service Inc. 9182 Independence Ave. Chatsworth, California 91311 www.itscnc.com Toll Free: 1.800.342.3475 NEW Brush Amplifiers For Fadal Machines AMP-0006N-ITS AMP-0021N-ITS NEW
More informationSeries 3000 Model R-107A
Series 3000 Model R-107A DUAL TONE SENDER INSTRUCTION MANUAL Monroe Electronics 100 Housel Ave Lyndonville NY 14098 800-821-6001 585-765-2254 fax 585-765-9330 monroe-electronics.com Printed in USA Copyright
More informationPage 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.
T O O L S A N D M AT E R I A L S R E Q U I R E D 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T A. Cabinet B. Wood Screw X4 C. Plastic wire connector x3 Page 1 I M P O R TA N T
More informationNSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC
Datasheet NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO 13849-1 EN 62061 EN 81-1 EN 50156-1 Approvals NSD-3580 24 VDC NSD-3590 115 TO 230 VAC Technical
More informationSeries 962. Operation Manual. Electronic Stager Control TIME OF DAY TIME OF REGEN HARDNESS FLOW SERIES 962 CAPACITY REGEN TIME REMAINING
Series 962 Electronic Stager Control Operation Manual TIME OF DAY TIME OF REGEN HARDNESS FLOW PM SERIES 962 CAPACITY SET REGEN REGEN TIME REMAINING 2 Table of Contents Declaration of Conformity................
More informationOVEN INDUSTRIES, INC. Model 5C7-362
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...
More informationADJUST AND SET UP FOR UNIT B
Amplitude Controller Model 6800 Series MODEL 6800.2T GENERAL PURPOSE Input: 240 VAC 50/60 HZ. Output: 0240 VAC Triple Unit Fuse Sizes: Unit A 5 AMPS, Unit B 8 AMPS, Unit C 2 AMPS 80% Duty Cycle at Rated
More informationSPECIFICATION, CONTROLS AND ACCESSORIES
AS440 Automatic Voltage Regulator (AVR) SPECIFICATION, CONTROLS AND ACCESSORIES English Original Instructions A043Y697 (Issue 2) Table of Contents 1. DESCRIPTION... 1 2. SPECIFICATION... 3 3. CONTROLS...
More informationImplementation Of Solid State Relays For Power System Protection
Implementation Of Solid State Relays For Power System Protection Nidhi Verma, Kartik Gupta, Sheila Mahapatra ABSTRACT: This paper provides the implementation of solid state relays for enhancement of power
More informationWHEN A PLC IS TOO MUCH, AND SPACE FOR
WHEN A PLC IS TOO MUCH, AND SPACE FOR A RELAY SEQUENCE CIRCUIT IS TOO LITTLE Pattern Selector 59 2.33 66 2.6 70 2.75 No programming required Select from among 15 preset patterns Wiring far simpler than
More informationPHASETRONICS. SCRPowerControlSpecialists. 1P1 Series. 20to600AmpModels SinglePhaseSCR OPERATIONANDSERVICEMANUAL MANUAL-1P REV2 REV06/13/13
PHASETRONICS TM SCRPowerControlSpecialists 1P1 Series 20to600AmpModels SinglePhaseSCR OPERATIONANDSERVICEMANUAL MANUAL-1P120600-REV2 REV06/13/13 Table of Contents Chapter 1 - Introduction... 4 1.1 General...
More informationELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL
ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL ESP Product Warranty Zener Electric warrant the Electronic Shear Pin against defective workmanship and materials for a period of 24 months from the
More informationMODEL 421 Over/Under Motor Load Monitor
MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart
More informationIntroduction To Temperature Controllers
Introduction To Temperature Controllers The Miniature CN77000 is a full featured microprocessor-based controller in a 1/16 DIN package. How Can I Control My Process Temperature Accurately and Reliably?
More information20 - Arc Guard Systems
Arc Guard Index Arc Guard - Arc Guard Arc Guard...1 -.14 Selection Arc Guard System, description...6...2...2 Description,...1 Description,...1 Description, with detectors...4 Description,...5 Detectors
More informationFAN4146 Ground Fault Interrupter
Features For Two-Wire ALCI and RCD Applications Precision Sense Amplifier and Bandgap Reference Built-in AC Rectifier Direct DC Coupled to Sense Coil Built-in Noise Filter Low-Voltage SCR Disable SCR Gate
More informationType CVX and CVX-1 Synchro-Verifier Relays
I.L. 41-682.11 Type CVX and CVX-1 Synchro-Verifier Relays TIME DIAL POTENTIOMETER (R3) CIRCLE ADJUST RESTRAINT ELECTROMAGNET Figure 1. CVX-1 Relay Front View, Out of Case OPERATING ELECTROMAGNET TELEPHONE
More informationBlue Point Engineering
lue Point Engineering Wizard - I Interface oard http://www.pesolutions.com (303) 651.3794 Pointing the Way to Solutions! Talking / Eye Moving Skull Connectors pplication Examples 7805 Eyeball Jar nimatronic
More informationBlue Point Engineering
Blue Point Engineering Instruction I www.bpesolutions.com Pointing the Way to Solutions! Puppet - II+ Controller (BPE No. PCA-0001) Servo Position Adjustment EEPROM Digital Button Power 5 Vdc Playback
More informationLeCroy Research Systems Model 365AL, Model 465, and Model 622 Logic Units
Page 1 of 5 365AL DUAL 4-FOLD MAJORITY LOGIC UNIT 465 TRIPLE 4-FOLD LOGIC UNIT (Note - the 465 is no longer available) 622 QUAD 2 LOGIC UNIT NIM Packaging High Speed Multiple Input Multiple Output Selectable
More informationHIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH
HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH Product Overview The FSP-3x1B is a family of passive infrared (PIR) outdoor sensors that raise or lower the electric lighting
More informationCyclone Upcut Cut off saw
Cyclone Upcut Cut off saw Operation manual WARNING The operator must thoroughly read and understand this manual before operating the cut off saw or starting any servicing. All safety and warning instructions
More informationwith Light Level, Isolated Relay and Manual On features
DT-200 version 3 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On features SPECIFICATIONS Voltage... 18-28VDC/VAC Current Consumption... 25mA Power Supply...WattStopper
More informationPULSE INPUT MODULE PI232/PI272 USER S MANUAL
UM-TS02 -E021 PROGRAMMABLE CONTROLLER PROSEC T2-series PULSE INPUT MODULE PI232/PI272 USER S MANUAL TOSHIBA CORPORATION Important Information Misuse of this equipment can result in property damage or human
More informationS1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR
RODIX INC. FEEDER CUBE FC90 Plus Series ADVANCED FEATURES Optional software features of the 24490 / 2449 circuit boards OVERVIEW: The FC90 Plus Series of feeder controls are built around the circuit boards
More informationPAiA 4780 Twelve Stage Analog Sequencer Design Analysis Originally published 1974
PAiA 4780 Twelve Stage Analog Sequencer Design Analysis Originally published 1974 DESIGN ANALYSIS: CLOCK As is shown in the block diagram of the sequencer (fig. 1) and the schematic (fig. 2), the clock
More informationAmetek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F
Ametek, Inc. Rotron Technical Products Division 100 East Erie St., Suite 200 Kent, Ohio 44240 User's 120 Volt, 800 Watt and 240 Volt, 1200 Watt Brushless Motor Drive Electronics 5.7" (145 mm) and 7.2"
More informationDistribution/Substation Transformer
Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation
More informationAC/DC ELECTRICAL SYSTEMS
AC/DC ELECTRICAL SYSTEMS LEARNING ACTIVITY PACKET CIRCUIT ANALYSIS BB227-BC03UEN LEARNING ACTIVITY PACKET 3 CIRCUIT ANALYSIS INTRODUCTION The previous LAP discussed how current, resistance, and voltage
More informationNo mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.
Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital
More informationQT111 QProx 8-pin Sensor See QT110 datasheet for primary information. This sheet only lists differences with the QT110.
QT11x VARIATIONS QT111 QT112 QT113 QT114 QT115 Longer recalibration timeouts Faster response time Variable gain to 0.03pF See separate QT114 datasheet Variable gain, daisychaining 3 April 2000 Copyright
More informationG-8945 TRANSFER-TRIP SYSTEM
T om or r ow 's T el em et r y T od a y! Da-Tel Research Company, Inc. Phone: (970) 249-6129 932 N. Park Avenue / P. O. Box 1206 Fax: (970) 249-8919 Montrose, Colorado 81402 www.da-telresearch.com Email:
More informationTimers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range
GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,
More informationAutomation Devices, Inc West Ridge Road, Fairview, PA AUTODEV.COM
Amplitude Controller Model 6800.1T GENERAL PURPOSE Automation Devices, Inc. 7050 West Ridge Road, Fairview, PA 164152099 Email SALES@AUTODEV. AUTODEV. Input: 120 VAC, 50/60 HZ. (Operating range 90130 VAC)
More informationThank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.
Instruction Manual TPSRF31 (181430) - BOSS TM Electronic RF Roomstat Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.
More informationEDACS WALL MOUNT STATION. Maintenance Manual. Mobile Communications LBI-31838A TABLE OF CONTENTS
A Mobile Communications EDACS WALL MOUNT STATION TABLE OF CONTENTS SYSTEM BOARD & REGULATOR BOARD.......... LBI-31892 KEY/DISPLAY BOARD MAINTENANCE MANUAL.... LBI-31940 Maintenance Manual Printed in U.S.A.
More informationMODEL KBWD-15 Pulse Width Modulated (PWM)
MODEL KBWD-15 Pulse Width Modulated (PWM) DC MOTOR SPEED CONTROL WHISPER DRIVE INSTALLATION AND OPERATING INSTRUCTIONS See Safety Warning on Page 1 and Application Note Warning on Page 2 The information
More informationGATE LIMIT RELAY KIT INSTALLATION INSTRUCTIONS GATE OPERATORS:
GATE LIMIT RELAY KIT INSTALLATION INSTRUCTIONS GATE OPERATORS: SW420/470/490, SL540/570/580/590 PARTS SUPPLIED Part # Qty Description 01-20322 1 Modification Instructions 27-20108 2 Cable Tie 76-20431
More informationMAINTENANCE MANUAL 1B170K17 FOUR SHOT AUTO RECLOSE RELAY
Sheet 1 of 9 MAINTENANCE MANUAL 1B170K17 FOUR SHOT AUTO RECLOSE RELAY The Maintenance Manual is to be read in conunction with Product/Test Manual Sheet 2 of 9 INDEX 1. FULL DESCRIPTION OF OPERATION 1.1
More informationThe MP SERIES CONTROLLER. User s Manual. ISE, Inc.
The MP SERIES CONTROLLER User s Manual ISE, Inc. 10100 Royalton Rd. Cleveland, OH 44133 USA Tel: (440) 237-3200 Fax: (440) 237-1744 http://variac.com Form No, 003-1622 Rev G 02/25/2009 Form No. 003-1622
More informationUS18-PL-5-N03 Ultrasonic Sensors
US18-PL-5-N03 Ultrasonic Sensors Miniature Ultrasonic Sensors with EACH-Mode Programming Fast, easy-to-use EACH-Mode programming; no potentiometer adjustments Ultra-compact housing One discrete output:
More informationFirst of all, power up the handsets and controllers!
First of all, power up the handsets and s!. Power the handsets: mains recharged handsets are supplied with NiCad batteries already fitted battery recharged handsets are supplied with a lithium battery
More informationPRODUCT/TEST MANUAL 2V162K12 VOLTAGE REGULATOR RELAY
Sheet 1 of 15 TEST DATE: CUSTOMER: SERIAL NO: OLTC ACKNOWLEDGE SETUP AUTOMATIC or FEEDBACK CONTROL PRODUCT/TEST MANUAL 2V162K12 VOLTAGE REGULATOR RELAY Issue Date Level A 06/01/1997 Initial issue. Summary
More informationMC133C/133Ci. Electric Power/Energy Calibrator. Operation manual
MC133C/133Ci Electric Power/Energy Calibrator Operation manual MC133C Electric Power/Energy Calibrator Powertek Content 1 Basic information... 5 2 Preparation for operation... 6 2.1 Inspecting package
More informationINSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12
INSTRUCTION MANUAL Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS Power Factor Controller A12 1. CONTENTS 1. CONTENTS 1 2. FEATURES 2 3. INSTALLATION, CONNECTION AND APPLYING POWER 2 4.
More informationSPECIFICATION, CONTROLS AND ACCESSORIES
MX341 Automatic Voltage Regulator (AVR) SPECIFICATION, CONTROLS AND ACCESSORIES English Original Instructions A043Y699 (Issue 2) Table of Contents 1. DESCRIPTION... 1 2. SPECIFICATION... 3 3. CONTROLS...
More informationSolid-State Digital Counter H7AN
Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or
More informationProgramming Parameters - Feature Comparison : Rev 1
Secure Wireless Microphone ELITE PRO CLASSIC Programming Parameters - Feature Comparison : Rev 1 How to use Programmer: Start Programming application Runs On PC or Mac running Windows 7/8. To put Handset
More informationSilvertel. Ag Features. 2. Description. Low Voltage DC LED Driver. Small SIL package. Selectable LED Current, 350mA, 500mA, 700mA &1000mA
Silvertel V1.2 Nov 2017 Datasheet Pb 1. Features Small SIL package Selectable LED Current, 350mA, 500mA, 700mA &1000mA Wide Input range 12V to 57V, SEPIC Buck/Boost Technology Very Long Life - No external
More informationLBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A.
D Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1 Maintenance Manual Printed in U.S.A. This page intentionally left blank 13 PARTS LIST 12 PARTS LIST LBI-31807 11 PARTS LIST 10 SCHEMATIC
More informationHLV Instruction & Operations Manual. Content
HLV-800-3 Instruction & Operations Manual Content 1 Chapter page 1. Certificate of conformity 3 2. Introduction 4 3. Safety instructions 5 4. Electrical connections 6 5. Warranty 7 6. Front panel operation
More informationHLV Instruction & Operations Manual
HLV-2000 Instruction & Operations Manual 1 Content Chapter page 1. Certificate of conformity 3 2. Introduction 4 3. Safety instructions 5 4. Electrical connections 6 5. Warranty 7 6. Front panel operation
More informationEE-110 Introduction to Engineering & Laboratory Experience Saeid Rahimi, Ph.D. Lab Timer: Blinking LED Lights and Pulse Generator
EE-110 Introduction to Engineering & Laboratory Experience Saeid Rahimi, Ph.D. Lab 9 555 Timer: Blinking LED Lights and Pulse Generator In many digital and analog circuits it is necessary to create a clock
More informationUSER MANUAL 2AMDI511VPVRDS
USER MANUAL 2AMDI511VPVRDS SUBJECT INDEX: DESCRIPTION TECHNICAL SPECIFICATION DEVICE POWER SUPPLY AND CONNECTION TO THE LED MODULE OPERATION MODES LINEAR POTENTIOMETER MODE 100KOHM MODE 0-10V/1-10V PASSIVE
More information1 Second Time Base From Crystal Oscillator
1 Second Time Base From Crystal Oscillator The schematic below illustrates dividing a crystal oscillator signal by the crystal frequency to obtain an accurate (0.01%) 1 second time base. Two cascaded 12
More informationUser Guide. AC/DC Mini Clamp Meter. Model
User Guide AC/DC Mini Clamp Meter Model 380941 P Introduction Congratulations on your purchase of Extech s AC/DC Clamp Meter. This professional meter, with proper care, will provide years of safe reliable
More informationModel 532 ma/v Loop Calibrator with Loop Diagnostic Operating Instructions
Practical Instrument Electronics Model 532 ma/v Loop Calibrator with Loop Diagnostic Operating Instructions A. Basic Keypad Operations j EZ-Check Switch/EZ-Step Pushbutton Slide the switch to select the
More informationExpandable Controller 3, 7, 11, 15 stations Installation and Programming Guide
seconds. This blinking cycle is to go on until the low battery condition is corrected. At that time the normal display returns. Also, while LO BA is blinking, if the dial is turned or any button is pressed,
More informationFLUX CORE 90 WELDER ASSEMBLY & OPERATING INSTRUCTIONS
Part #20280 FLUX CORE 90 WELDER ASSEMBLY & OPERATING INSTRUCTIONS SPECIFICATIONS Output Amperage No Load Voltage Max. Input Amperage Input Voltage 90 27 20 Amp 120V, 1ph, 60Hz Rated Duty Cycle 20% @ 90
More informationTECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection
Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information
More informationExercise 2: Source and Sink Current
Digital Logic Fundamentals Tri-State Output Exercise 2: Source and Sink Current EXERCISE OBJECTIVE When you have completed this exercise, you will be able to demonstrate how a tri-state buffer output can
More informationRODIX INCORPORATED TOLL FREE (800) , FAX (815) rodix.com
RODIX INCORPORATED TOLL FREE (800) 5621868, FAX (815) 3164701 Email custserve@rodix.com rodix.com FEEDER CUBE FC92 Plus, P/N 1210008450 GENERAL PURPOSE MODEL IMPORTANT: APPLICATION NOTE File No. E183233
More informationCoils & Electronic Controls
HYDRAFORCE Coils & Electronic Controls COILS FOR SOLENOID OPERATED VALVES Standard Coils and Proportional Valve Coils... 3.200.1 Series E Water/Weather Resistant Coils... 3.400.1 ELECTRONIC CONTROLS FOR
More informationR-Series R235LS 2-Channel Power Amplifier with Local Source Switching
R-Series R235LS 2-Channel Power Amplifier with Local Source Switching User s Manual On Off R235LS POWER A MPLIFIER IMPORTANT SAFEGUARDS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
More informationASHIDA Numerical 3OC + 1EF Protection Relay
PROTH. ERR L5 PKP FAULT DT REC LOCK BF L6 L7 CLOSE TRIP ADR 241B Protection Features : 4 Element (3 Phase + EF + Sensitive EF) Over current IDMT/DMT with instant trip. Programmable (Non- Volatile) Setting
More informationOperation Manual February Opticom Infrared System
Operation Manual February 2008 Opticom Infrared System M195/196, M9192, M292, M9592, M592 Emitters M511, M521, M522 Detectors M262, M562 Phase Selectors M360, M560 System Chassis M5168, M5575 Interface
More informationSUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand
More informationf i r e - p a r t s. c o m
Model: CON 1001-1 INSTALLATION AND OPERATING INSTRUCTIONS SINGLE-FUNCTION WIRELESS REMOTE CONTROL SYSTEM FOR OPERATING VALVES WITH ON/OFF LATCHING SOLENOIDS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION
More informationMotor Control Development Kit
User s Manual, V 1.0, June 2003 Motor Control Development Kit A reference design for low voltage 3-phase AC induction and brushless DC motor control. Microcontrollers Never stop thinking. Revision History:2003-06
More information1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA
28231 Ave Crocker Suite 10 Valencia, CA 91355 818-700-8600 Servodynamics.com INFORMATION MANUAL 1525-BRS SERV O D YN A M ICS U SA www.servodynamics.com D y n ad r iv e Bru sh INDEX Page INTRODUCTION 2
More informationDMX Digital-Servo Board
Version 1.0 2012 WD197 Overview he DMX DigitalServo module is designed to provide 8 consecutive channels of output from a standard DMX protocol input signal. he outputs may be configured to be 5VDC digital
More information