SIMATIC HMI Panel PC Ex OG, Thin Client Ex OG Notes Product Information

Size: px
Start display at page:

Download "SIMATIC HMI Panel PC Ex OG, Thin Client Ex OG Notes Product Information"

Transcription

1 SIMATIC HMI Panel PC Ex OG, Thin Client Ex OG Notes Product Information Legal Information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product / system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products / systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Validity This product information is valid for devices with the following article numbers: SIMATIC HMI Panel PC Ex OG: 6AV SIMATIC HMI Thin Client Ex OG: 6AV Important Note This product information contains important notes. The information in this product information takes precedence over statements in the operating instructions and online help. Carefully read through these notes, as they contain useful information for you. Observe information in documents enclosed. Siemens AG Alle Rechte vorbehalten A5E AA, 06/2017

2 Service and support You can find additional information and support for the products described on the Internet at the following addresses: Technical support ( Support request form ( After Sales Information System SIMATIC IPC/PG ( SIMATIC Documentation Collection ( Your local representative ( Training center ( Industry Mall ( When contacting your local representative or Technical Support, please have the following information at hand: MLFB of the device BIOS version for industrial PC or image version of the device Other installed hardware Other installed software Tools & downloads Please check regularly if updates and hotfixes are available for download to your device. The download area is available on the Internet at the following link: After Sales Information System SIMATIC IPC/PG ( Trademarks All names identified by are registered trademarks of Siemens. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Digital Factory Postfach NÜRNBERG Notes A5E AA, 06/2017

3 Notice to device designation Panel PC Ex OG devices The table below lists the Panel PC Ex OG devices together with their marking on the type plate and the Operating Instructions. HW-Rev. ET-/MT-4x8: HW-Rev. ET-/MT-4x8: MLFB Designation Siemens Device designation (includes) 6AV abcd-efx a = A Panel PC Ex, Zone 1, 15 ET-438-xxx-3xxxx1xxx1x-B3x a = B Panel PC Ex, Zone 1, 21,5 ET-498-xxx-3xxxx1xxx1x-B3x a = C Panel PC Ex, Zone 2, 15 MT-438-xxx-3xxxx1xxx1x-B3x a = D Panel PC Ex, Zone 2, 21,5 MT-498-xxx-3xxxx1xxx1x-B3x AV abcd-efx b= A 1x 1000Base-TX in combination with WLAN xx-4x8-1tx-3xxxx1xxx1x-b3x b = B 2x 1000Base-TX xx-4x8-2tx-3xxxx1xxx1x-b3x b = C 2x 100Base-FX xx-4x8-2fx-3xxxx1xxx1x-b3x AV abcd-efx c = 1 SSD 80 GB, 4 GB RAM xx-4x8-xxx-33x6x1xxx1x-b3x c = 2 SSD 240 GB, 8 GB RAM xx-4x8-xxx-34xcx1xxx1x-b3x c = 3 SSD 480 GB, 8 GB RAM xx-4x8-xxx-34xex1xxx1x-b3x AV abcd-efx d = 1 Windows 7 Ultimate xx-4x8-xxx-3xxxx1xxx1e-b3x d = 2 Windows Embedded 7 xx-4x8-xxx-3xxxx1xxx1f-b3x AV abcd-efx e = 1 Standard TFT, 15", no Touch xx-438-xxx-3x0x01xxx1x-b3x e = 2 Sunlight Readable, 15", no Touch xx-438-xxx-3x1x01xxx1x-b3x e = 3 Sunlight Readable, 21,5", no Touch xx-498-xxx-3x1x01xxx1x-b3x e = 4 Standard TFT, 15", kapazitiver Touch xx-438-xxx-3x0x31xxx1x-b3x e = 5 Sunlight Readable, 15", capacitive Touch xx-438-xxx-3x1x31xxx1x-b3x e = 6 Sunlight Readable, 21,5", capacitive Touch xx-498-xxx-3x1x31xxx1x-b3x AV abcd-efx f = A no WLAN, no Bluetooth, no RFID xx-4x8-xxx-3xxxx10xx1x-b3x f = B WLAN 2,4 GHz, no Bluetooth, no RFID xx-4x8-xxx-3xxxx11xx1x-b3x f = C WLAN 2,4 GHz and 5 GHz, no Bluetooth, no RFID xx-4x8-xxx-3xxxx12xx1x-b3x f = D no WLAN, Bluetooth, no RFID xx-4x8-xxx-3xxxx13xx1x-b3x f = E WLAN 2,4 GHz, Bluetooth, no RFID xx-4x8-xxx-3xxxx14xx1x-b3x f = F WLAN 2,4 GHz and 5 GHz, Bluetooth, no RFID xx-4x8-xxx-3xxxx15xx1x-b3x f = G no WLAN, no Bluetooth, RFID xx-4x8-xxx-3xxxx16xx1x-b3x f = H WLAN 2,4 GHz, no Bluetooth, RFID xx-4x8-xxx-3xxxx17xx1x-b3x f = J WLAN 2,4 GHz and 5 GHz, no Bluetooth, RFID xx-4x8-xxx-3xxxx18xx1x-b3x f = K no WLAN, Bluetooth, RFID xx-4x8-xxx-3xxxx19xx1x-b3x f = L WLAN 2,4 GHz, Bluetooth, RFID xx-4x8-xxx-3xxxx1axx1x-b3x f = M WLAN 2,4 GHz and 5 GHz, Bluetooth, RFID xx-4x8-xxx-3xxxx1bxx1x-b3x

4 Options A01 24V DC power supply xx-4x8-xxx-3xxxx0xxx1x-b3x B01 CAN-Bus interface xx-4x8-xxx-3xxxx1x3x1x-b3x D01 Outdoor -40 C xx-4x8-xxx-3xxxx1xxx1x-b3x

5 Notice to device designation Thin Client Ex OG devices The table below lists the Thin Client Ex OG devices together with their marking on the type plate and the Operating Instructions. HW-Rev. ET-/MT-5x8: HW-Rev. ET-/MT-5x8: MLFB Designation Siemens Device designation (includes) 6AV7200-3abcd-efx a = A Thin Client Ex, Zone 1, 15 ET-538-xxx-23x5x1xxx1x-B3x a = B Thin Client Ex, Zone 1, 21,5 ET-598-xxx-23x5x1xxx1x-B3x a = C Thin Client Ex, Zone 2, 15 MT-538-xxx-23x5x1xxx1x-B3x a = D Thin Client Ex, Zone 2, 21,5 MT-598-xxx-23x5x1xxx1x-B3x AV7200-3abcd-efx b = A 1x 1000Base-TX in combination with WLAN xx-5x8-1tx-23x5x1xxx1x-b3x b = B 2x 1000Base-TX xx-5x8-2tx-23x5x1xxx1x-b3x b = C 2x 100Base-FX xx-5x8-2fx-23x5x1xxx1x-b3x AV7200-3abcd-efx c = 1 SSD 60 GB, 4 GB RAM xx-5x8-xxx-23x5x1xxx1x-b3x AV7200-3abcd-efx d = 1 Windows 10 IoT and Remote Firmware xx-5x8-xxx-23x5x1xxx1m-b3x AV7200-3abcd-efx e = 1 Standard TFT, 15", no Touch xx-538-xxx xxx1x-b3x e = 2 Sunlight Readable, 15", no Touch xx-538-xxx xxx1x-b3x e = 3 Sunlight Readable, 21,5", no Touch xx-598-xxx xxx1x-b3x e = 4 Standard TFT, 15", kapazitiver Touch xx-538-xxx xxx1x-b3x e = 5 Sunlight Readable, 15", capacitive Touch xx-538-xxx xxx1x-b3x e = 6 Sunlight Readable, 21,5", capacitive Touch xx-598-xxx xxx1x-b3x AV7200-3abcd-efx f = A no WLAN, no Bluetooth, no RFID xx-5x8-xxx-23x5x10xx1x-b3x f = B WLAN 2,4 GHz, no Bluetooth, no RFID xx-5x8-xxx-23x5x11xx1x-b3x f = C WLAN 2,4 GHz and 5 GHz, no Bluetooth, no RFID xx-5x8-xxx-23x5x12xx1x-b3x f = D no WLAN, Bluetooth, no RFID xx-5x8-xxx-23x5x13xx1x-b3x f = E WLAN 2,4 GHz, Bluetooth, no RFID xx-5x8-xxx-23x5x14xx1x-b3x f = F WLAN 2,4 GHz and 5 GHz, Bluetooth, no RFID xx-5x8-xxx-23x5x15xx1x-b3x f = G no WLAN, no Bluetooth, RFID xx-5x8-xxx-23x5x16xx1x-b3x f = H WLAN 2,4 GHz, no Bluetooth, RFID xx-5x8-xxx-23x5x17xx1x-b3x f = J WLAN 2,4 GHz and 5 GHz, no Bluetooth, RFID xx-5x8-xxx-23x5x18xx1x-b3x f = K no WLAN, Bluetooth, RFID xx-5x8-xxx-23x5x19xx1x-b3x f = L WLAN 2,4 GHz, Bluetooth, RFID xx-5x8-xxx-23x5x1axx1x-b3x f = M WLAN 2,4 GHz and 5 GHz, Bluetooth, RFID xx-5x8-xxx-23x5x1bxx1x-b3x

6 Options A01 24V DC power supply xx-4x8-xxx-3xxxx0xxx1x-b3x D01 Outdoor -40 C xx-4x8-xxx-3xxxx1xxx1x-b3x

7 Instruction manual Panel PC Ex OG Thin Client Ex OG HW-Rev. ET-xx8: HW-Rev. MT-xx8: Instruction manual version: Issue:

8 Table of contents Table of contents Description Page Table of contents 8 1 Intended use 10 2 Marking Type code Type code definition Ex marking ATEX / IECEx ET-xx8 HMI SERIES MT-xx8 HMI SERIES Ex marking TR (EAC) ET-xx8 HMI SERIES MT-xx8 HMI SERIES Ex marking FM USA ET-xx8 HMI SERIES MT-xx8 HMI SERIES Ex marking FM Canada ET-xx8 HMI SERIES MT-xx8 HMI SERIES Certificates Notified Body ID number Temperature range Type of protection Warnings Serial number Manufacturing date Manufacturer 14 3 Applied standards 15 4 Electrical parameter Intrinsically safe interfaces (Ex ia) X30 PB - power button X31 - Fan X32 - Barcode / reader X33 / X34 - USB KB/M X35 - USB X36 / X37 - RF1 / RF Bluetooth - B Reader interface RFID - RF1, RF Inherently safe optical interfaces (Ex op is) X20 / X21 Fibre 1 / Fibre 2 type FX X20 / X21 Fibre 1 / Fibre 2 type SX X20 / X21 Fibre 1 / Fibre 2 type LX X22 Fibre 3 type OSX X22 Fibre 3 type OLX Non intrinsically safe interfaces (Ex e / Ex na) X1 - Power 19 Page 8 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

9 Table of contents X2 / X3 - copper1 / copper X4 - DC out X5 - CAN X6 - USB X7 - RSxxx X8 - DVI X9 - Audio / Video X10 - SATA Connection overview terminal assignment 21 5 Instructions for safety Putting into service Use Assembling Maintenance, overhaul and repair Installation Details for connection compartments Details for electrical connection of Interfaces X1... X9, X31 X Details for electrical connection of Interface X Earthing Adjustment 26 6 Panel mounting with xx8 Mounting-Kit 26 7 Special conditions of use 27 8 Special tools 27 9 Cells and Batteries Drawings Panel mounting with xx8 Mounting-Kit Control Drawing FM USA / Canada Declaration of EC conformity ET-xx MT-xx Release notes 34 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 9 of 36

10 Intended use 1 Intended use The HMIs of the xx8 SERIES - device platform SHARK - are explosion-proof equipment for installation in hazardous areas. They are designed for operation, visualization and processes control in these areas. Whilst the ET-xx8 devices can be installed in zones 1, 2, 21 and 22 (EPL Gb, Db) according to ATEX directive, IEC and Canadian requirement as well as Class I, Zone 1 & 2; Class I, Division 2; Zone 21 & 22; and Class II, Division 2 for the US. The MT-xx8 devices are suitable for installation in zones 2 and 22 (EPL Gc, Dc) according to ATEX directive, IEC and Canadian requirement as well as Class I, Zone 2, Class I, Division 2, Zone 22 and Class II, Division 2 for the US. All devices have a modular structure, which makes changes and maintenance easy. The HMIs of the xx8 SERIES consist of a display and a E-Box module which are mounted together. The display module mostly covers the display (available in different sizes) and the E-Box module mostly covers the electronic. The connection of external cables is realized via an integrated connection compartments for Ex e / Ex na and Ex ia circuits. 2 Marking 2.1 Type code a-*b8-c-d-e-f-g-h* any alphanumeric or symbolic characters, without relevance for explosion protection OptionBox version RFID version Bluetooth version Wireless version Power supply version Ethernet interface Family code (fixed to 8) Display size code any alphanumeric or symbolic characters, without relevance for explosion protection Zone declaration Page 10 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

11 Marking Type code definition Number from Possible Description type code value ET Devices for zone 1, zone 21, EPL Gb, Db a MT Devices for zone 2, zone 22, EPL Gc, Dc 4 SERIES 400, Panel PC * 5 SERIES 500, Thin Clients 3 15" display b 9 21,5" display 8 8 Generation 8 *TX * = number of Ethernet interface (1 or 2) Copper Ethernet interface 10/100/1000Base-TX *FX * = number of Ethernet interface (1 or 2) Optical fibre Ethernet interface 100Base-FX, multi-mode c *SX * = number of Ethernet interface (1 or 2) Optical fibre Ethernet interface 1000Base-SX, multi-mode *LX * = number of Ethernet interface (1 or 2) Optical fibre Ethernet interface 1000Base-LX, single mode 00 Other interface d W00 No wireless RF interface integrated W02 Wireless interface RF 2.4 GHz e W55 Wireless interface 2x RF 5 GHz W25 Wireless interface RF 2.4 GHz and RF 5 GHz f C0 No Reader interface integrated C1 Reader interface RFID MHz integrated C2 Reader interface RFID 2.4 GHz integrated C3 Reader interface RFID MHz integrated, MIFARE / DESFire / EV1, CRYPT g C4 Reader interface RFID MHz integrated, MIFARE / DESFire / EV1, ASCII C5 Reader interface RFID MHz integrated, LEGIC, CRYPT C6 Reader interface RFID MHz integrated, LEGIC, ASCII C7 Reader interface RFID MHz integrated, NFC O00 No OptionBox interface h OSX Optical fibre OptionBox interface 1000Base-SX, multi-mode OLX Optical fibre OptionBox interface 1000Base-LX, single mode Additional type code definition for device specification * * (see further documentation) AC W05 B0 AC power supply version Wireless interface RF 5 GHz No Bluetooth integrated DC W22 B1 DC power supply version Wireless interface 2x RF 2.4 GHz Bluetooth integrated OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 11 of 36

12 Marking 2.2 Ex marking ATEX / IECEx ATEX and IECEx marking according to IEC and ATEX directive 2014/34/EU ET-xx8 HMI SERIES Version 2014/34/EU prefix Ex marking Gas e II 2(1) G Ex eb q [ia op is Ga] IIC T4 Gb Dust e II 2(1) D Ex tb [ia op is Da] IIIC T115 C Db MT-xx8 HMI SERIES Version 2014/34/EU prefix Ex marking Gas e II 3(1) G Ex ec nr [ia op is Ga] IIC T4 Gc Dust e II 3(1) D Ex tc [ia op is Da] IIIC T115 C Dc 2.3 Ex marking TR (EAC) ET-xx8 HMI SERIES Version Ex marking Gas 1Ex e q [ia op is Ga] IIC T4 Gb X Dust Ex tb [ia op is Da] IIIC T115 C Db X MT-xx8 HMI SERIES Version Ex marking Gas 2Ex na nr [ia op is Ga] IIC T4 Gc X Dust Ex tb [ia op is Da] IIIC T115 C Dc X 2.4 Ex marking FM USA US marking according to ANSI/UL ET-xx8 HMI SERIES Version Ex marking Gas Class I, Zone 1 AEx eb q [ia op is Ga] IIC T4 Gb Class I, Div. 2 Groups A, B, C, D T4 Version Zone 21, AEx tb [ia op is Da] IIIC T115 C Db Class II, Div. 2 Groups F, G T4 Class III MT-xx8 HMI SERIES Version Ex marking Gas Class I, Zone 2 AEx na nr [ia op is Ga] IIC T4 Gc Class I, Div. 2 Groups A, B, C, D T4 Version Zone 22, AEx tc [ia op is Da] IIIC T115 C Dc Class II, Div. 2 Groups F, G T4 Class III Page 12 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

13 Marking 2.5 Ex marking FM Canada Canadian marking according to CSA C22.2 No ET-xx8 HMI SERIES Version Gas Version Ex marking Ex eb q [ia Ga] IIC T4 Gb Class I, Div. 2 Groups A, B, C, D T4 Zone 21, Ex tb [ia Da] IIIC T115 C Db Class II, Div. 1 Groups E, F, G T4 Class III MT-xx8 HMI SERIES Version Gas Version Ex marking Ex na nr [ia Ga] IIC T4 Gc Class I, Div. 2 Groups A, B, C, D, T4 Zone 22, Ex tc [ia Da] IIIC T115 C Dc Class II, Div. 2 Groups E, F, G T4 Class III 2.6 Certificates ATEX EC-Type Examination Certification number: BVS 14 ATEX E 134 X IECEx Certification number: BVS X TR (EAC) Certification number: FM USA Certification number: FM Canada Certification number: TC RU C-DE.ME92.B FM 16 US 0278 X FM 16 CA 0141 X 2.7 Notified Body ID number Notified Body ID number: Temperature range Temperature range: -40 C +70 C 2.9 Type of protection Type of protection: IP66 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 13 of 36

14 Marking 2.10 Warnings Caution! The HMI device surface may heat up at ambient temperatures higher than 45 C! Caution at contact! Do not open! This container has been permanently sealed and cannot be repaired. Isolate supply and all Ex e / Ex na circuits and wait 5 minutes before opening the connection compartments! Additional for MT-xx8 HMIs: Do not open, maintain or service in an area where an explosive atmosphere may be present Serial number Serial number is printed on a label Manufacturing date Manufacturing date is printed on a label Manufacturer Manufacturers name: R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D Köln Page 14 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

15 Applied standards 3 Applied standards Standard IEC : 2011 IEC : 2015 IEC : 2015 IEC : 2011 IEC : 2010 IEC : 2006 IEC : 2015 IEC : 2013 ANSI/UL ANSI/UL ANSI/UL ANSI/UL ANSI/UL ANSI/UL ANSI/ISA ANSI/UL FM 3616 CSA C22.2 No CSA C22.2 No CSA C22.2 No CSA C22.2 No CSA C22.2 No CSA C22.2 No CSA C22.2 No CSA C22.2 No Classification General requirements Protection by powder filling "q" Protection by increased safety "e" Protection by intrinsic safety "i" Protection by type of protection "n" Equipment with EPL "Ga" Optical radiation op is Protected by enclosures "t" (dust ignition protection) General requirements Protection by powder filling "q" Protection by increased safety "e" Protection by intrinsic safety "i" Protection by type of protection "n" Equipment with EPL "Ga" Optical radiation op is Protected by enclosures "t" (dust ignition protection) Dust-Ignitionproof Electrical Equipment General Requirements General requirements Protection by powder filling "q" Protection by increased safety "e" Protection by intrinsic safety "i" Protection by type of protection "n" Intrinsically safe electrical systems Equipment with EPL "Ga" Protected by enclosures "t" (dust ignition protection) OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 15 of 36

16 Electrical parameter 4 Electrical parameter 4.1 Intrinsically safe interfaces (Ex ia) X30 PB - power button X30: PB, power button (X30-1, X30-2) connected parallel, GND (X30-3, X30-4): Max. output voltage U o = 5.36 VDC Max. output current I o = 46 ma Max. output power P o = W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = 1 20 µh C o and L o pairs directly above / underneath each other may be used X31 - Fan X31: Fan power (X31-1), (X31-3) each circuit, GND (X31-2, X31-4): Max. output voltage U o = VDC Max. output current I o = 189 ma Max. output power P o = W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = µh C o and L o pairs directly above / underneath each other may be used. Page 16 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

17 Electrical parameter X32 - Barcode / reader Notes: For installation at X32 must be observed, that the connected device can be supplied either from the 10.4 V (X32-1) or the 5.36V (X32-2) power circuit. The terminals 1 and 2 shall NOT be connected at the same time! The terminal X32 includes one common terminal (X32-5) for the GND connection of the power and the data interfaces. When only one common GND wire from the cable of the connected device is used, then the total current must be observed for determination of external inductances! X32: Barcode / reader 10,4 V power (X32-1), GND (X32-5): Max. output voltage U o = 10.4 VDC Max. output current I o = 391 ma Max. output power P o = W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = µh C o and L o pairs directly above / underneath each other may be used. X32: Barcode / reader 5,36 V power (X32-2), GND (X32-5): Max. output voltage U o = 5.36 VDC Max. output current I o = 420 ma Max. output power P o = W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = 1 2 µh C o and L o pairs directly above / underneath each other may be used. X32: Barcode / reader data TXD (X32-3), RXD (X32-4) each circuit, GND (X32-5): Max. output voltage U o = between RxD and GND, resp. TxD and GND ±5.35 VDC between RxD and TxD ±10.70 VDC Effective internal capacitance C i = negligible Effective internal inductance L i = negligible Max. output current I o = 16 ma Max. output power P o = W Max. input voltage U i = ±12.5 VDC Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = 1 20 µh C o and L o pairs directly above / underneath each other may be used. Note: The external capacitances and inductances were calculated for the maximum voltage of 10.7 V. If only one of both signals RXD or TXD is connected, only a reduced voltage of 5.35 V has to be considered. Therewith, the following values are permissible: Max. external capacitance Co = µf Max. external inductance L o = 1 2 µh OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 17 of 36

18 Electrical parameter X33 / X34 - USB KB/M X33 / X34: USB KB/M terminals + (X33/34-1), D- (X33/34-2), D+ (X33/34-3), GND (X33/34-4): Max. output voltage U o = 5.36 VDC Max. output current I o = 249,85 ma Max. output power P o = 0,518 W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = 0,68 1,68 2,68 3,68 4,68 µh C o and L o pairs directly above / underneath each other may be used X35 - USB X35: USB terminals + (X35-1), D- (X35-2), D+ (X35-3), GND (X35-4): Max. output voltage U o = 5.36 VDC Max. output current I o = 1,264 A Max. output power P o = 2,949 W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = 0,68 1,68 2,68 3,68 4,68 µh C o and L o pairs directly above / underneath each other may be used X36 / X37 - RF1 / RF2 X36 / X37: RF1 / RF2, type W02, W05, W22, W55, W25 each circuit: Radio frequency f o = 2.4 GHz 5 GHz Max. RF threshold power P o = 17 dbm (50 mw) It is responsible of the installer to ensure that the RF threshold power radiated from the antenna must be limited to max. 33 dbm (2 W) for Gas Group IIC. The calculation of this should take into account of output power of the interface and the gain of the antenna. It is permissible to consider losses in the cable in this calculation. Example of RF threshold power calculation: Output power of the interface X36 / X37 = 17 dbm (50 mw) Coaxial cable loss = 2 db Gain of the antenna = 5 dbi RF threshold power radiated from the antenna = 17 dbm 2 db + 5 dbi = 20 dbm (100 mw) 20 dbm (100 mw) < 33 dbm (2 W) so that the operation of this coaxial cable and antenna combination used in this example pass the requirements for use in Gas Group IIC. The antennas connected to the interface X36 / X37 must be installed in accordance with earthing requirements of IEC : 2014 clause or local installation codes (such as NEC or CEC). 4.2 Bluetooth - B1 Radio frequency f o = 2.4 GHz Max. RF threshold power P o = 33 dbm / 2 W Page 18 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

19 Electrical parameter 4.3 Reader interface RFID - RF1, RF2 Radio frequency for type RF1 f o = MHz Radio frequency for type RF2 f o = 2.4 GHz Max. RF threshold power P o = 33 dbm / 2 W 4.4 Inherently safe optical interfaces (Ex op is) X20 / X21 Fibre 1 / Fibre 2 type FX Wavelength = 1310 nm Nominal optical radiated power = mw Max. optical radiated power under fault conditions = 35 mw X20 / X21 Fibre 1 / Fibre 2 type SX Wavelength = 850 nm Nominal optical radiated power = 0.22 mw Max. optical radiated power under fault conditions = 35 mw X20 / X21 Fibre 1 / Fibre 2 type LX Wavelength = 1310 nm Nominal optical radiated power = 0.22 mw Max. optical radiated power under fault conditions = 35 mw X22 Fibre 3 type OSX Wavelength = 850 nm Nominal optical radiated power = 0.22 mw Max. optical radiated power under fault conditions = 35 mw X22 Fibre 3 type OLX Wavelength = 1310 nm Nominal optical radiated power = 0.22 mw Max. optical radiated power under fault conditions = 35 mw 4.5 Non intrinsically safe interfaces (Ex e / Ex na) X1 - Power Nominal voltage = for device variant AC = VAC for device variant DC = VDC Nominal current = for device variant AC = 5 A for device variant DC = 8 A Nominal power = 150 W Max. input voltage U m = 250 VAC X2 / X3 - copper1 / copper2 Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 19 of 36

20 Electrical parameter X4 - DC out Nominal voltage terminal 1 = 12 VDC Nominal voltage terminal 4 = 24 VDC Max. input voltage U m = 250 VAC X5 - CAN Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC X6 - USB Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC X7 - RSxxx Nominal voltage = 12 VAC / VDC Max. input voltage U m = 250 VAC X8 - DVI Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC X9 - Audio / Video Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC X10 - SATA Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC Page 20 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

21 Electrical parameter 4.6 Connection overview terminal assignment Terminal Pin Definition (circuit board) / view Typical cable color / plug design Connection / function Ex e compartment / terminals X V / L Black Power supply of the POWER V / L Black HMI device 3 GND / N Blue (either AC or DC) 4 GND / N Blue 5 PE / Earth Green / Yellow 6 PE / Earth Green / Yellow X2 * 1000Base-TX 100Base-TX Data line CAT1 1 D1+ TX+ White / Orange Copper connection 1 2 D1- TX- Orange 3 D2+ RX+ White / Green 4 D2- RX- Green 5 D3+ White / Blue 6 D3- Blue 7 D4+ White / Brown 8 D4- Brown X3 * 1000Base-TX 100Base-TX Data line CAT2 1 D1+ TX+ White / Orange Copper connection 2 2 D1- TX- Orange 3 D2+ RX+ White / Green 4 D2- RX- Green 5 D3+ White / Blue 6 D3- Blue 7 D4+ White / Brown 8 D4- Brown X20 * SC Duplex Data line FO 1 jack FO connection 1 at SERIES 400 / 500 Type FX (100Base-FX) X21 * SC Duplex Data line FO 2 jack FO connection 2 at SERIES 400 / 500 Type FX (100Base-FX) NOTICE * Please note that the Ethernet connection is either for a copper connection or for an optical fibre connection (see order versions)! OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 21 of 36

22 Electrical parameter Terminal Pin Definition (circuit board) / view Typical cable color / plug design Connection / function Ex e compartment / terminals X V 12 and / or 24 V DC DC out 2 GND Output 3 GND max. load 500 ma V for each output X5 CAN 1 CAN1 L CAN-Bus connection 2 CAN1 H (Order option) 3 CAN2 L (not possible at 4 CAN2 H SERIES 500) (2 chanel) X6 1 +5V Red USB connection USB 2 D - White 3 D + Green 4 GND Black X7 RS-232 RS-422 RS-485 Serial interface RSxxx 1 TxD TxD-A A (COM) 2 RxD RxD-B RS-232 / RS-422 / RS RTS TxD-B B 4 CTS RxD-A 5 GND X8 1 D0- DVI connection DVI 2 D0+ 3 GND 4 D1-5 D1+ 6 GND 7 D2-8 D2+ 9 CLK- 10 CLK+ 11 GND 12 DDC Clock 13 DDC Data 14 GND 15 +5V 16 Hot Plug X9 Audio / Video connection Audio / 1 L out Line out left Video 2 R out Line out right 3 GND 4 Video Video input 5 GND (not possible at SERIES 400 / 500) Page 22 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

23 Electrical parameter Terminal Pin Definition (circuit board) / view Typical cable color / plug design Connection / function Ex i compartment / terminals X30 1 PB On / Off switch PB 2 GND connection 3 GND 4 GND X31 1 +FAN Fan connection FAN 2 GND 3 +FAN 4 GND X V Barcode- / card reader RS232 / V connection Power 3 GND 4 RxD 5 TxD X V Red USB connection USB 2 D - White 3 D + Green 4 GND Black X V Red USB connection USB 2 D - White 3 D + Green 4 GND Black X V Red USB connection USB 2 D - White (terminals or jack) 3 D + Green 4 GND Black USB jack Type A X36 X37 SMA-Reverse jack SMA-Reverse jack WLAN Antenna connection 1 (for 2.4 GHz antenna) WLAN Antenna connection 2 (for 5 GHz antenna) OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 23 of 36

24 Instructions for safety 5 Instructions for safety 5.1 Putting into service No special conditions. 5.2 Use See "intended use". 5.3 Assembling The device may be installed and operated in any position. The device must be mounted securely, using the threads or holes integrated into the enclosure or at the outer cooling fins of the display module. 5.4 Maintenance, overhaul and repair The devices are maintenance-free across their entire lifespan. System maintenance should focus on the following: a. Seal wear b. Display damage c. All screws are tightened fast d. All cables and lines are properly connected and undamaged The HMIs of the xx8 SERIES consist of a display module and an E-Box module which are mounted together. For service proposals these modules are interchangeable. All circuits must be de-energised for interchanging. The mounting torque of the screws form mounting the display and E-Box module together is 4 5 N. This screws are located under the covers of the connection compartments. The display and the E-Box module are not intended to be repaired by customers. WARNING Do not open! The enclosure has been permanently sealed and cannot be repaired. Do not open, maintain or service in an area where an explosive atmosphere may be present! For access into the connections of the E-Box, isolate supply and all Ex e / Ex na circuits, wait 5 minutes before opening the connection compartment! 5.5 Installation Details for connection compartments The cover of the connection compartments (Ex i / Ex e / Ex na) includes mounting options for associated equipment (e.g. cable glands, cable connectors, buttons). The associated equipment to be mounted in the cover of the connection compartments must pass IP66 rating and adhere to the relevant IEC, ANSI/UL or CSA C22.2 requirements. - for Ex e connection compartments the IEC, ANSI/UL or CSA C22.2 number for Ex i connection compartments the IEC, ANSI/UL or CSA C22.2 number for Ex na connection compartments the IEC, ANSI/UL or CSA C22.2 number The details of used associated equipment must be observed (for example permitted cable diameter for used cable glands, tighten rules, cable clamping). Page 24 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

25 Instructions for safety Country-specific regulations must be observed, in particular any possible changes in ambient parameters (e.g. ambient temperature range). Unused openings must be closed by a suitable blind plug. Threaded entries with tapered threads must be used with not less than 3 threads. Parallel threads must be used with a tolerance class of 6H or better and an additional seal or gasket. The mounting torque of the connection compartment cover screws is N Details for electrical connection of Interfaces X1... X9, X31 X35 Stripping length: Mounting torque: 7 mm N Connectable conductor cross section: - rigid [mm²] or (AWG): or (24 12) - flexible [mm²] or (AWG): or (24 12) Multi-conductor connection (two conductor with the same cross section and conductor type): - rigid [mm²] or (AWG): or (24 16) - flexible [mm²] or (AWG): or (24 *1) * Note: No direct equivalent AWG size listed in IEC Multi-conductor connection for X1 as screw terminal (two conductor with the same cross section and conductor type): - rigid [mm²] or (AWG): or (24 16) - flexible [mm²] or (AWG): or (24 18) The connectors are designed to be readily connected or disconnected without load. The device must be disconnected from the mains before assembly, maintenance, or repair. The connector fixing screws must be fitted. It is the responsibility of the installer to ensure the maximum rated current of 12 A for each contact of connector terminal X1. In case of screw terminals for X1 the maximum rated current of 16 A for each contact of X1 must be guaranteed. The maximum voltage of 250 V and a short current of 1500 A must not be exceeded at the place of installation. Connection to the device shall be done with copper wire rated for at least 90 C. Where the ambient temperature is expected to be greater than 60 C (to the rated maximum) the connections shall be done with copper wire rated for 105 C Details for electrical connection of Interface X10 The connector X10 is usable with manufacturers approved connectors / devices only. OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 25 of 36

26 Panel mounting with xx8 Mounting-Kit Earthing The devices must be earthed with a core cross section of at least 4 mm 2 or in line with applicable standards. An external earth connection facility is provided. 5.6 Adjustment n. A. 6 Panel mounting with xx8 Mounting-Kit The xx8 device can be mounted in an enclosure with suitable cut-out using an xx8 mounting frame kit (Mounting-Kit). This mounting kit is approved for mounting in an Ex e, Ex p or Ex tb protected enclosure. The xx8 mounting kit consist of sealing material and a mounting frame. The sealing material is applied at the rear side of the xx8 equipment. The mounting frame fixes the xx8 device in the cut out and is mounted from rear side. The assembly is shown in drawing Rev02 xx8 Mounting Assembly Overview. All screws of the mounting frame must be tightened with a torque of 1.5 Nm to 2 Nm. Page 26 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

27 Special conditions of use 7 Special conditions of use The intrinsically safe circuits are connected to earth. Along the intrinsically safe circuits, potential equalization must exist. For devices with wireless interface (characters W02, W05, W22, W55 or W25 in the type code): The maximum radio frequency power threshold at the antennas connected to the interfaces X36 and X37 shall not exceed the admissible value of 2 W for group IIC. The calculation of this should be taken into account the output power of the transmitter (X36 / X37), the gain of the antenna and the losses in the cable. The intrinsic safe circuits at X36 und X37 are connected to earth. The antennas connected to the interface must be installed in accordance with earthing requirements of EN , of National Electrical Code ANSI/NFPA 70 and of Canadian Electric Code CSA C22.1. The covers of the connection compartments are equipped with cable glands and blind plugs. Optionally they can be equipped with plugs and sockets and switches. This equipment has to fulfill IP66 and be separately certified for the respective type of protection. 8 Special tools n. A. 9 Cells and Batteries The internal battery is interchangeable by manufacturer only. OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 27 of 36

28 Drawings 10 Drawings Further drawings can be found in additional documents Panel mounting with xx8 Mounting-Kit Page 28 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

29 Control Drawing 11 Control Drawing 11.1 FM USA / Canada OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 29 of 36

30 Control Drawing Page 30 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

31 Control Drawing OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 31 of 36

32 Declaration of EC conformity 12 Declaration of EC conformity 12.1 ET-xx8 Page 32 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

33 Declaration of EC conformity 12.2 MT-xx8 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 33 of 36

34 Release notes 13 Release notes The chapter entitled "Release Notes" contains all the changes made in every version of the Instruction manual. Version Changing / correction "Device designation (includes)" at Panel PC Addition of Thin Client Ex OG Changing content "Intended use" Adaption of type code to variants OG Addition of "Device platform SHARK" Addition of information according to ATEX 1. Supplement Addition of information according to IECEx Issue No. 2 Changing HW-Revision at cover Changing type code value for reader interface Addition of type code at reader interface Changing ATEX direction 94/9/EG according to 2014/30/EU Changing Ex marking at Gas Addition of TR (EAC) certification Addition of FM certification USA and Canada Changing Conformity to standards Changing standard clause in section "Antenna earthing requirements" Addition of Warning "High Temperature" Addition of Control Drawing FM Addition of section "Panel mount with xx8 Mounting-Kit" Addition of drawing "Panel mount with xx8 Mounting-Kit" Addition of text according to "Control Drawing" in section "Intrinsically safe interfaces" Addition of "local installation codes NEC or CEC" in section "X36 / X37 - RF1 / RF2" Addition of section "Connection overview terminal assignment" Addition of warnings in section "Maintenance, overhaul and repair" Addition of section "Details for connection compartments" with FM standards Addition of sentences with "rated temperatures at copper wires" in section "Details for electrical connection of Interfaces X1... X9, X31 X35" Addition of pictures in section "Earthing" Addition of section "Special conditions of use" with FM standards Renew Declaration of EC conformity Removal of previous release notes Text-, layout- and formal corrections Page 34 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /

35

36 Siemens AG Division Digital Factory Postfach NÜRNBERG

Operating Manual. isolate501

Operating Manual. isolate501 Operating Manual isolate501 Document Number 413569 (See Last Page for Revision Details). Copyright Extronics Ltd, 2015 Page 2 of 21 Contents 1 Introduction... 4 2 Safety Information and Notes... 5 2.1

More information

SIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4

SIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4 Characteristics 1 Ordering data 2 SIMATIC Ident RFID systems Operating Instructions Installing and mounting 3 Connecting the antenna 4 Antenna parameter assignment 5 Antenna patterns 6 Maximum read/write

More information

Installation & Operating Manual. iwap202

Installation & Operating Manual. iwap202 Installation & Operating Manual iwap202 This page is intentionally left blank. Document Number 409345 (based on 407655) (See Last Page for Revision Details) For warranty information, refer to Terms and

More information

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax: OVERVIEW The Solexy RX series explosion proof and intrinsically safe antenna coupler is an integrated protection device that facilitates non-ex certified radio antenna installation in hazardous areas.

More information

SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions SIMATIC Ident RFID systems Compact Operating Instructions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to

More information

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC Properties 1 Parameters 2 Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) Manual

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING

More information

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes

More information

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Installation guide 873 SmartRadar Control Unit & Antenna Unit Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl

More information

Installation guide 971 SmartRadar LTi

Installation guide 971 SmartRadar LTi Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl

More information

OPTIWAVE 7300 C Supplementary instructions

OPTIWAVE 7300 C Supplementary instructions OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

SIMATIC RTLS. Localization systems SIMATIC RTLS PCB OEM AX (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01

SIMATIC RTLS. Localization systems SIMATIC RTLS PCB OEM AX (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01 SIMATIC RTLS Localization systems (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01 Legal information Warning notice system This manual contains notices you have to observe in order to ensure

More information

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i Intrinsically Safe Compact Controller CTR 210i Intrinsically Safe Bargraph Indicator BGI 210i DMT 02 ATEX E 148 2. Supplement also grahics display Revision 4 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.:

More information

Safety Manual. Omni-ID UHF Tags

Safety Manual. Omni-ID UHF Tags Safety Manual Omni-ID UHF Tags This page is intentionally left blank. Document Number 330556 (See Last Page for Revision Details) 2012 Extronics Limited. This document is Copyright Extronics limited. Extronics

More information

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70163240 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, Bayern 63911 GERMANY Attention: Harald Gollas The products listed

More information

Fieldbus Isolating Repeater Series 9185/11

Fieldbus Isolating Repeater Series 9185/11 www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional

More information

Isolators A3/1.

Isolators A3/1. > Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]

More information

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications

More information

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.

More information

Installation guide 877 FDI Field Display & Interface

Installation guide 877 FDI Field Display & Interface Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No 9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used

More information

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry. SIMATIC ET 200SP Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual Edition 02/2014 Answers for industry. DI 8xNAMUR HF digital input module (6ES7131-6TF00-0CA0) SIMATIC ET 200SP DI 8xNAMUR HF

More information

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions

More information

Intrinsic Safety Control Drawing

Intrinsic Safety Control Drawing s Intrinsic Safety Control Drawing A5E00455287 system in total "No revision to drawing without prior Approval by FM Approvals!" PLC PC Non hazardous area PROFIBUS DP RS 485-IS Coupler PROFIBUS RS 485-IS

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011 Quick Installation Guide Temperature Transmitter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information Product Certifications End www.rosemount.com

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

Installation guide 854 XTG Level Gauge

Installation guide 854 XTG Level Gauge Installation guide 854 XTG Level Gauge July 2008 Part no. 4416.276 Rev. 5 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

Loop Powered Indicator

Loop Powered Indicator Instruction Manual Model PD686 Loop Powered Indicator M397 January 3, 2019 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Tel: 978-486-9800 Fax: 978-486-0170 PD686 I.S. and N.I. NEMA 4X, IP67

More information

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,

More information

Rudder or propeller angular position transmitter KINAX WT720

Rudder or propeller angular position transmitter KINAX WT720 Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - # Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

iant101 Zone 1 Omni Directional Antenna

iant101 Zone 1 Omni Directional Antenna iant101 Zone 1 Omni Directional Antenna External Antenna offering increased flexibility for positioning and greatly enhanced RF Propagation. ATEX Ex t IIIC T85 C Db IECEx Ex t IIIC T85 C Db -40 C to 60

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

Safety Instructions Proline Promass 100

Safety Instructions Proline Promass 100 XA00160D/06/EN/03.14 71261250 Products Solutions Services Safety Instructions Proline Promass 100 Modbus RS485 Cl.I Div.1, Zone 1 for IS (Ex i Intrinsically safe version) C US Document: XA00160D Safety

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

FM Safety Manual. Omni-ID UHF Tags

FM Safety Manual. Omni-ID UHF Tags FM Safety Manual Omni-ID UHF Tags This page is intentionally left blank. Document Number 334169 (See Last Page for Revision Details) 2012 Extronics Limited. This document is Copyright Extronics limited.

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

Binary Output without Power Supply Series 9176

Binary Output without Power Supply Series 9176 Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output

More information

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T** Assembly Instructions for: PL ** Series Junction Boxes AI 23 / Issue W - 01/ IMPORTANT: This document should be read carefully before commencing installation Zones of Use of Box CAT II 2G for use in Zone

More information

Installation guide 970 SmartRadar ATi

Installation guide 970 SmartRadar ATi Installation guide 970 SmartRadar ATi July 2008 Part no. 4416.717 Rev. 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com Website

More information

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R User's Manual ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 Table of contents Table of contents

More information

Safety Instructions Proline Promass 300

Safety Instructions Proline Promass 300 XA01507D/06/EN/01.16 71327925 Products Solutions Services Safety Instructions Proline Promass 300 Class I, Zone 2 AEx/Ex na ic IIC Class I, Zone 2, AEx/Ex na nc ic IIC Class I Division 2 C US Document:

More information

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter Operating Instruction OI/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter Measurement made easy Change from one to two columns Short product description Coriolis

More information

Installation guide 970, 971 and 973 series SmartRadar

Installation guide 970, 971 and 973 series SmartRadar Installation guide 970, 971 and 973 series SmartRadar August 2008 Part no. 4416.719 Rev. 1 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

FLEX Ex V ac In/Quad-Ex dc Out Power Supply Installation Instructions FLEX Ex 85 250V ac In/Quad-Ex dc Out Power Supply Catalog Number 1797-PS1N Topic Important User Information 2 About the Power Supplies 3 Understand System Planning 4 Electrostatic

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T** Assembly Instructions for: PL ** Series Junction Boxes IMPORTANT: This document should be read carefully before commencing installation Zones of Use for Box - as defined in IEC/EN 00-0 and IEC/EN 00--1

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

Remote I/O. 74 Remote I/O. Remote I/O System

Remote I/O. 74 Remote I/O. Remote I/O System System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

Inductive sensor slot-type SI2-K08-AP7

Inductive sensor slot-type SI2-K08-AP7 SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type

More information

External brake resistor AX2090-BW5x

External brake resistor AX2090-BW5x Documentation External brake resistor AX2090-BW5x Accessories for Beckhoff servo drive AX5000 Version: Date: 1.3 2018-03-14 Table of content Table of content 1 Foreword... 5 1.1 Notes on the documentation...

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas

iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas This page is intentionally left blank. Document Number 403449

More information

SET Installation and Operating Instructions. Level switch for two sensors

SET Installation and Operating Instructions. Level switch for two sensors Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 20.2.2013 Internet: www.labkotec.fi 1/14 SET-2000 Level switch for two sensors Copyright 2013 Labkotec

More information

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

SINAMICS drives. SINAMICS DCM as a DC voltage source. Application. Answers for industry. Edition 01/2014

SINAMICS drives. SINAMICS DCM as a DC voltage source. Application. Answers for industry. Edition 01/2014 SINAMICS drives SINAMICS DCM as a DC voltage source Application Edition 01/2014 Answers for industry. Compact User Manual Legal information Warning notice system This manual contains notices you have to

More information

Radio Control Installation and Operating Instructions System 4

Radio Control Installation and Operating Instructions System 4 Radio Control Installation and Operating Instructions System 4 P.O. Box 403, One Cedar Parkway, Jackson, WI 53037 Phone: 800-628-1909 Fax: 262-677-2058 Revision: April 19, 2012 Contents Introduction 3

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc IECEx Installation Instructions EB-20025744 Rev. AC December 2015 Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc 5700 IECEx Installation Instructions EB-20025744

More information

C-Bus 8 Channel Low Voltage Relay

C-Bus 8 Channel Low Voltage Relay SLC5108RELVP Instruction Bulletin Retain for future use. 63249-420-325A1 Instruction Bulletin 07/2009 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to

More information

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters Installation Instructions P/N MMI-20011709, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters Note: For hazardous installations in Europe, refer to standard EN

More information

RX Series UL Listed Explosion Proof Antenna Coupler For Hazardous Area Applications Installation & Operation Manual (IOM)

RX Series UL Listed Explosion Proof Antenna Coupler For Hazardous Area Applications Installation & Operation Manual (IOM) OVERVIEW The Solexy RX explosion proof antenna coupler is an integrated protection device that facilitates radio antenna installation in hazardous areas. The patented (7,057,577) RX coupler features a

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

SITRANS TH200/TH300 SITRANS T. Temperature transmitter SITRANS TH200/TH300. Introduction 1. General safety notes. Description 3.

SITRANS TH200/TH300 SITRANS T. Temperature transmitter SITRANS TH200/TH300. Introduction 1. General safety notes. Description 3. Introduction 1 General safety notes 2 SITRANS T Temperature transmitter Operating Instructions Description 3 Installation 4 Connecting 5 Operation 6 Functional safety 7 Commissioning 8 Functions 9 Service

More information

Wireless Base Radio. Wireless Transmitters

Wireless Base Radio. Wireless Transmitters XYR 5000 Wireless Base Radio 34-XY-03-55 9/2006 WBR/WBH Europe PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The Wireless Base Radio (WBR) is part of the XYR 5000 family of wireless products.

More information

Industrial Pressure Transducers

Industrial Pressure Transducers Industrial Pressure Transducers User s Manual T Model T Model The Swagelok T model transducer is engineered for use in industrial pressure measurement applications where intrinsically safe ratings are

More information

1-830 SERIES DISPLACEMENT TRANSMITTER

1-830 SERIES DISPLACEMENT TRANSMITTER 1-830 SERIES DISPLACEMENT TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description RAD-IN/OUT-D Digital extension modules for the bidirectional wireless system INTERFACE Data sheet 102122_en_0 PHOENIX CONTACT 2010-02-2 1 Description The RAD-ISM-...-SET-BD-BUS-ANT bidirectional wireless

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Introduction 1 General safety notes 2 SITRANS Temperature transmitter Operating Instructions Description 3 Installation 4 Connecting 5 Operation 6 Functional safety 7 Commissioning 8 Functions 9 Service

More information

Safety Instructions Proline Promag 500

Safety Instructions Proline Promag 500 XA01524D/06/EN/01.16 71327947 Products Solutions Services Safety Instructions Proline Promag 500 Cl.I, II, III Div.1 for XP (Ex d Flameproofed version) C US Document: XA01524D Safety instructions for electrical

More information

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

MACX MCR-EX-SL-RPSSI-I-UP(-SP) Supply and input signal conditioner, Ex-i, with wide range supply Data sheet 103561_en_00 PHOENIX CONTACT 2014-08-19 1 Description The MACX MCR-EX-SL-RPSSI-I-UP(-SP) repeater power supply and input signal

More information

SITRANS TH200/TH300 SITRANS T. Temperature transmitter SITRANS TH200/TH300. Introduction 1. Safety information. Description.

SITRANS TH200/TH300 SITRANS T. Temperature transmitter SITRANS TH200/TH300. Introduction 1. Safety information. Description. Introduction 1 Safety information 2 SITRANS T Temperature transmitter Operating Instructions Description 3 Installation 4 Connecting 5 Operation 6 Functional safety 7 Commissioning 8 Functions 9 Technical

More information

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition, Ex instruction manual Rotamass Coriolis mass flow meter IM 01U10X02-00EN-R_002, 2nd edition, 2016-09-22 Table of contents Table of contents 1 Introduction... 4 1.1 Scope of application... 4 1.2 Applicable

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

SINVERT. Technical requirements for medium-voltage transformers for use with SINVERT central inverters. Application manual 04/2012

SINVERT. Technical requirements for medium-voltage transformers for use with SINVERT central inverters. Application manual 04/2012 Technical requirements for medium-voltage transformers for use with SINVERT central inverters Application manual 04/2012 SINVERT Answers for the environment. Technical requirements for medium- Technical

More information

Installation Instructions

Installation Instructions SYSTXBBSAM01 EVOLUTION SYSTEM ACCESS MODULE Installation Instructions NOTE: Read the entire instruction manual before starting the installation. pointsett U.S. Pat No. 7,415,102 Fig. 1 - Evolution System

More information

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-I-LP-NC 2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information