SIMATIC HMI Panel PC Ex OG, Thin Client Ex OG Notes Product Information
|
|
- Willa Leonard
- 6 years ago
- Views:
Transcription
1 SIMATIC HMI Panel PC Ex OG, Thin Client Ex OG Notes Product Information Legal Information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product / system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products / systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Validity This product information is valid for devices with the following article numbers: SIMATIC HMI Panel PC Ex OG: 6AV SIMATIC HMI Thin Client Ex OG: 6AV Important Note This product information contains important notes. The information in this product information takes precedence over statements in the operating instructions and online help. Carefully read through these notes, as they contain useful information for you. Observe information in documents enclosed. Siemens AG Alle Rechte vorbehalten A5E AA, 06/2017
2 Service and support You can find additional information and support for the products described on the Internet at the following addresses: Technical support ( Support request form ( After Sales Information System SIMATIC IPC/PG ( SIMATIC Documentation Collection ( Your local representative ( Training center ( Industry Mall ( When contacting your local representative or Technical Support, please have the following information at hand: MLFB of the device BIOS version for industrial PC or image version of the device Other installed hardware Other installed software Tools & downloads Please check regularly if updates and hotfixes are available for download to your device. The download area is available on the Internet at the following link: After Sales Information System SIMATIC IPC/PG ( Trademarks All names identified by are registered trademarks of Siemens. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Digital Factory Postfach NÜRNBERG Notes A5E AA, 06/2017
3 Notice to device designation Panel PC Ex OG devices The table below lists the Panel PC Ex OG devices together with their marking on the type plate and the Operating Instructions. HW-Rev. ET-/MT-4x8: HW-Rev. ET-/MT-4x8: MLFB Designation Siemens Device designation (includes) 6AV abcd-efx a = A Panel PC Ex, Zone 1, 15 ET-438-xxx-3xxxx1xxx1x-B3x a = B Panel PC Ex, Zone 1, 21,5 ET-498-xxx-3xxxx1xxx1x-B3x a = C Panel PC Ex, Zone 2, 15 MT-438-xxx-3xxxx1xxx1x-B3x a = D Panel PC Ex, Zone 2, 21,5 MT-498-xxx-3xxxx1xxx1x-B3x AV abcd-efx b= A 1x 1000Base-TX in combination with WLAN xx-4x8-1tx-3xxxx1xxx1x-b3x b = B 2x 1000Base-TX xx-4x8-2tx-3xxxx1xxx1x-b3x b = C 2x 100Base-FX xx-4x8-2fx-3xxxx1xxx1x-b3x AV abcd-efx c = 1 SSD 80 GB, 4 GB RAM xx-4x8-xxx-33x6x1xxx1x-b3x c = 2 SSD 240 GB, 8 GB RAM xx-4x8-xxx-34xcx1xxx1x-b3x c = 3 SSD 480 GB, 8 GB RAM xx-4x8-xxx-34xex1xxx1x-b3x AV abcd-efx d = 1 Windows 7 Ultimate xx-4x8-xxx-3xxxx1xxx1e-b3x d = 2 Windows Embedded 7 xx-4x8-xxx-3xxxx1xxx1f-b3x AV abcd-efx e = 1 Standard TFT, 15", no Touch xx-438-xxx-3x0x01xxx1x-b3x e = 2 Sunlight Readable, 15", no Touch xx-438-xxx-3x1x01xxx1x-b3x e = 3 Sunlight Readable, 21,5", no Touch xx-498-xxx-3x1x01xxx1x-b3x e = 4 Standard TFT, 15", kapazitiver Touch xx-438-xxx-3x0x31xxx1x-b3x e = 5 Sunlight Readable, 15", capacitive Touch xx-438-xxx-3x1x31xxx1x-b3x e = 6 Sunlight Readable, 21,5", capacitive Touch xx-498-xxx-3x1x31xxx1x-b3x AV abcd-efx f = A no WLAN, no Bluetooth, no RFID xx-4x8-xxx-3xxxx10xx1x-b3x f = B WLAN 2,4 GHz, no Bluetooth, no RFID xx-4x8-xxx-3xxxx11xx1x-b3x f = C WLAN 2,4 GHz and 5 GHz, no Bluetooth, no RFID xx-4x8-xxx-3xxxx12xx1x-b3x f = D no WLAN, Bluetooth, no RFID xx-4x8-xxx-3xxxx13xx1x-b3x f = E WLAN 2,4 GHz, Bluetooth, no RFID xx-4x8-xxx-3xxxx14xx1x-b3x f = F WLAN 2,4 GHz and 5 GHz, Bluetooth, no RFID xx-4x8-xxx-3xxxx15xx1x-b3x f = G no WLAN, no Bluetooth, RFID xx-4x8-xxx-3xxxx16xx1x-b3x f = H WLAN 2,4 GHz, no Bluetooth, RFID xx-4x8-xxx-3xxxx17xx1x-b3x f = J WLAN 2,4 GHz and 5 GHz, no Bluetooth, RFID xx-4x8-xxx-3xxxx18xx1x-b3x f = K no WLAN, Bluetooth, RFID xx-4x8-xxx-3xxxx19xx1x-b3x f = L WLAN 2,4 GHz, Bluetooth, RFID xx-4x8-xxx-3xxxx1axx1x-b3x f = M WLAN 2,4 GHz and 5 GHz, Bluetooth, RFID xx-4x8-xxx-3xxxx1bxx1x-b3x
4 Options A01 24V DC power supply xx-4x8-xxx-3xxxx0xxx1x-b3x B01 CAN-Bus interface xx-4x8-xxx-3xxxx1x3x1x-b3x D01 Outdoor -40 C xx-4x8-xxx-3xxxx1xxx1x-b3x
5 Notice to device designation Thin Client Ex OG devices The table below lists the Thin Client Ex OG devices together with their marking on the type plate and the Operating Instructions. HW-Rev. ET-/MT-5x8: HW-Rev. ET-/MT-5x8: MLFB Designation Siemens Device designation (includes) 6AV7200-3abcd-efx a = A Thin Client Ex, Zone 1, 15 ET-538-xxx-23x5x1xxx1x-B3x a = B Thin Client Ex, Zone 1, 21,5 ET-598-xxx-23x5x1xxx1x-B3x a = C Thin Client Ex, Zone 2, 15 MT-538-xxx-23x5x1xxx1x-B3x a = D Thin Client Ex, Zone 2, 21,5 MT-598-xxx-23x5x1xxx1x-B3x AV7200-3abcd-efx b = A 1x 1000Base-TX in combination with WLAN xx-5x8-1tx-23x5x1xxx1x-b3x b = B 2x 1000Base-TX xx-5x8-2tx-23x5x1xxx1x-b3x b = C 2x 100Base-FX xx-5x8-2fx-23x5x1xxx1x-b3x AV7200-3abcd-efx c = 1 SSD 60 GB, 4 GB RAM xx-5x8-xxx-23x5x1xxx1x-b3x AV7200-3abcd-efx d = 1 Windows 10 IoT and Remote Firmware xx-5x8-xxx-23x5x1xxx1m-b3x AV7200-3abcd-efx e = 1 Standard TFT, 15", no Touch xx-538-xxx xxx1x-b3x e = 2 Sunlight Readable, 15", no Touch xx-538-xxx xxx1x-b3x e = 3 Sunlight Readable, 21,5", no Touch xx-598-xxx xxx1x-b3x e = 4 Standard TFT, 15", kapazitiver Touch xx-538-xxx xxx1x-b3x e = 5 Sunlight Readable, 15", capacitive Touch xx-538-xxx xxx1x-b3x e = 6 Sunlight Readable, 21,5", capacitive Touch xx-598-xxx xxx1x-b3x AV7200-3abcd-efx f = A no WLAN, no Bluetooth, no RFID xx-5x8-xxx-23x5x10xx1x-b3x f = B WLAN 2,4 GHz, no Bluetooth, no RFID xx-5x8-xxx-23x5x11xx1x-b3x f = C WLAN 2,4 GHz and 5 GHz, no Bluetooth, no RFID xx-5x8-xxx-23x5x12xx1x-b3x f = D no WLAN, Bluetooth, no RFID xx-5x8-xxx-23x5x13xx1x-b3x f = E WLAN 2,4 GHz, Bluetooth, no RFID xx-5x8-xxx-23x5x14xx1x-b3x f = F WLAN 2,4 GHz and 5 GHz, Bluetooth, no RFID xx-5x8-xxx-23x5x15xx1x-b3x f = G no WLAN, no Bluetooth, RFID xx-5x8-xxx-23x5x16xx1x-b3x f = H WLAN 2,4 GHz, no Bluetooth, RFID xx-5x8-xxx-23x5x17xx1x-b3x f = J WLAN 2,4 GHz and 5 GHz, no Bluetooth, RFID xx-5x8-xxx-23x5x18xx1x-b3x f = K no WLAN, Bluetooth, RFID xx-5x8-xxx-23x5x19xx1x-b3x f = L WLAN 2,4 GHz, Bluetooth, RFID xx-5x8-xxx-23x5x1axx1x-b3x f = M WLAN 2,4 GHz and 5 GHz, Bluetooth, RFID xx-5x8-xxx-23x5x1bxx1x-b3x
6 Options A01 24V DC power supply xx-4x8-xxx-3xxxx0xxx1x-b3x D01 Outdoor -40 C xx-4x8-xxx-3xxxx1xxx1x-b3x
7 Instruction manual Panel PC Ex OG Thin Client Ex OG HW-Rev. ET-xx8: HW-Rev. MT-xx8: Instruction manual version: Issue:
8 Table of contents Table of contents Description Page Table of contents 8 1 Intended use 10 2 Marking Type code Type code definition Ex marking ATEX / IECEx ET-xx8 HMI SERIES MT-xx8 HMI SERIES Ex marking TR (EAC) ET-xx8 HMI SERIES MT-xx8 HMI SERIES Ex marking FM USA ET-xx8 HMI SERIES MT-xx8 HMI SERIES Ex marking FM Canada ET-xx8 HMI SERIES MT-xx8 HMI SERIES Certificates Notified Body ID number Temperature range Type of protection Warnings Serial number Manufacturing date Manufacturer 14 3 Applied standards 15 4 Electrical parameter Intrinsically safe interfaces (Ex ia) X30 PB - power button X31 - Fan X32 - Barcode / reader X33 / X34 - USB KB/M X35 - USB X36 / X37 - RF1 / RF Bluetooth - B Reader interface RFID - RF1, RF Inherently safe optical interfaces (Ex op is) X20 / X21 Fibre 1 / Fibre 2 type FX X20 / X21 Fibre 1 / Fibre 2 type SX X20 / X21 Fibre 1 / Fibre 2 type LX X22 Fibre 3 type OSX X22 Fibre 3 type OLX Non intrinsically safe interfaces (Ex e / Ex na) X1 - Power 19 Page 8 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
9 Table of contents X2 / X3 - copper1 / copper X4 - DC out X5 - CAN X6 - USB X7 - RSxxx X8 - DVI X9 - Audio / Video X10 - SATA Connection overview terminal assignment 21 5 Instructions for safety Putting into service Use Assembling Maintenance, overhaul and repair Installation Details for connection compartments Details for electrical connection of Interfaces X1... X9, X31 X Details for electrical connection of Interface X Earthing Adjustment 26 6 Panel mounting with xx8 Mounting-Kit 26 7 Special conditions of use 27 8 Special tools 27 9 Cells and Batteries Drawings Panel mounting with xx8 Mounting-Kit Control Drawing FM USA / Canada Declaration of EC conformity ET-xx MT-xx Release notes 34 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 9 of 36
10 Intended use 1 Intended use The HMIs of the xx8 SERIES - device platform SHARK - are explosion-proof equipment for installation in hazardous areas. They are designed for operation, visualization and processes control in these areas. Whilst the ET-xx8 devices can be installed in zones 1, 2, 21 and 22 (EPL Gb, Db) according to ATEX directive, IEC and Canadian requirement as well as Class I, Zone 1 & 2; Class I, Division 2; Zone 21 & 22; and Class II, Division 2 for the US. The MT-xx8 devices are suitable for installation in zones 2 and 22 (EPL Gc, Dc) according to ATEX directive, IEC and Canadian requirement as well as Class I, Zone 2, Class I, Division 2, Zone 22 and Class II, Division 2 for the US. All devices have a modular structure, which makes changes and maintenance easy. The HMIs of the xx8 SERIES consist of a display and a E-Box module which are mounted together. The display module mostly covers the display (available in different sizes) and the E-Box module mostly covers the electronic. The connection of external cables is realized via an integrated connection compartments for Ex e / Ex na and Ex ia circuits. 2 Marking 2.1 Type code a-*b8-c-d-e-f-g-h* any alphanumeric or symbolic characters, without relevance for explosion protection OptionBox version RFID version Bluetooth version Wireless version Power supply version Ethernet interface Family code (fixed to 8) Display size code any alphanumeric or symbolic characters, without relevance for explosion protection Zone declaration Page 10 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
11 Marking Type code definition Number from Possible Description type code value ET Devices for zone 1, zone 21, EPL Gb, Db a MT Devices for zone 2, zone 22, EPL Gc, Dc 4 SERIES 400, Panel PC * 5 SERIES 500, Thin Clients 3 15" display b 9 21,5" display 8 8 Generation 8 *TX * = number of Ethernet interface (1 or 2) Copper Ethernet interface 10/100/1000Base-TX *FX * = number of Ethernet interface (1 or 2) Optical fibre Ethernet interface 100Base-FX, multi-mode c *SX * = number of Ethernet interface (1 or 2) Optical fibre Ethernet interface 1000Base-SX, multi-mode *LX * = number of Ethernet interface (1 or 2) Optical fibre Ethernet interface 1000Base-LX, single mode 00 Other interface d W00 No wireless RF interface integrated W02 Wireless interface RF 2.4 GHz e W55 Wireless interface 2x RF 5 GHz W25 Wireless interface RF 2.4 GHz and RF 5 GHz f C0 No Reader interface integrated C1 Reader interface RFID MHz integrated C2 Reader interface RFID 2.4 GHz integrated C3 Reader interface RFID MHz integrated, MIFARE / DESFire / EV1, CRYPT g C4 Reader interface RFID MHz integrated, MIFARE / DESFire / EV1, ASCII C5 Reader interface RFID MHz integrated, LEGIC, CRYPT C6 Reader interface RFID MHz integrated, LEGIC, ASCII C7 Reader interface RFID MHz integrated, NFC O00 No OptionBox interface h OSX Optical fibre OptionBox interface 1000Base-SX, multi-mode OLX Optical fibre OptionBox interface 1000Base-LX, single mode Additional type code definition for device specification * * (see further documentation) AC W05 B0 AC power supply version Wireless interface RF 5 GHz No Bluetooth integrated DC W22 B1 DC power supply version Wireless interface 2x RF 2.4 GHz Bluetooth integrated OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 11 of 36
12 Marking 2.2 Ex marking ATEX / IECEx ATEX and IECEx marking according to IEC and ATEX directive 2014/34/EU ET-xx8 HMI SERIES Version 2014/34/EU prefix Ex marking Gas e II 2(1) G Ex eb q [ia op is Ga] IIC T4 Gb Dust e II 2(1) D Ex tb [ia op is Da] IIIC T115 C Db MT-xx8 HMI SERIES Version 2014/34/EU prefix Ex marking Gas e II 3(1) G Ex ec nr [ia op is Ga] IIC T4 Gc Dust e II 3(1) D Ex tc [ia op is Da] IIIC T115 C Dc 2.3 Ex marking TR (EAC) ET-xx8 HMI SERIES Version Ex marking Gas 1Ex e q [ia op is Ga] IIC T4 Gb X Dust Ex tb [ia op is Da] IIIC T115 C Db X MT-xx8 HMI SERIES Version Ex marking Gas 2Ex na nr [ia op is Ga] IIC T4 Gc X Dust Ex tb [ia op is Da] IIIC T115 C Dc X 2.4 Ex marking FM USA US marking according to ANSI/UL ET-xx8 HMI SERIES Version Ex marking Gas Class I, Zone 1 AEx eb q [ia op is Ga] IIC T4 Gb Class I, Div. 2 Groups A, B, C, D T4 Version Zone 21, AEx tb [ia op is Da] IIIC T115 C Db Class II, Div. 2 Groups F, G T4 Class III MT-xx8 HMI SERIES Version Ex marking Gas Class I, Zone 2 AEx na nr [ia op is Ga] IIC T4 Gc Class I, Div. 2 Groups A, B, C, D T4 Version Zone 22, AEx tc [ia op is Da] IIIC T115 C Dc Class II, Div. 2 Groups F, G T4 Class III Page 12 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
13 Marking 2.5 Ex marking FM Canada Canadian marking according to CSA C22.2 No ET-xx8 HMI SERIES Version Gas Version Ex marking Ex eb q [ia Ga] IIC T4 Gb Class I, Div. 2 Groups A, B, C, D T4 Zone 21, Ex tb [ia Da] IIIC T115 C Db Class II, Div. 1 Groups E, F, G T4 Class III MT-xx8 HMI SERIES Version Gas Version Ex marking Ex na nr [ia Ga] IIC T4 Gc Class I, Div. 2 Groups A, B, C, D, T4 Zone 22, Ex tc [ia Da] IIIC T115 C Dc Class II, Div. 2 Groups E, F, G T4 Class III 2.6 Certificates ATEX EC-Type Examination Certification number: BVS 14 ATEX E 134 X IECEx Certification number: BVS X TR (EAC) Certification number: FM USA Certification number: FM Canada Certification number: TC RU C-DE.ME92.B FM 16 US 0278 X FM 16 CA 0141 X 2.7 Notified Body ID number Notified Body ID number: Temperature range Temperature range: -40 C +70 C 2.9 Type of protection Type of protection: IP66 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 13 of 36
14 Marking 2.10 Warnings Caution! The HMI device surface may heat up at ambient temperatures higher than 45 C! Caution at contact! Do not open! This container has been permanently sealed and cannot be repaired. Isolate supply and all Ex e / Ex na circuits and wait 5 minutes before opening the connection compartments! Additional for MT-xx8 HMIs: Do not open, maintain or service in an area where an explosive atmosphere may be present Serial number Serial number is printed on a label Manufacturing date Manufacturing date is printed on a label Manufacturer Manufacturers name: R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D Köln Page 14 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
15 Applied standards 3 Applied standards Standard IEC : 2011 IEC : 2015 IEC : 2015 IEC : 2011 IEC : 2010 IEC : 2006 IEC : 2015 IEC : 2013 ANSI/UL ANSI/UL ANSI/UL ANSI/UL ANSI/UL ANSI/UL ANSI/ISA ANSI/UL FM 3616 CSA C22.2 No CSA C22.2 No CSA C22.2 No CSA C22.2 No CSA C22.2 No CSA C22.2 No CSA C22.2 No CSA C22.2 No Classification General requirements Protection by powder filling "q" Protection by increased safety "e" Protection by intrinsic safety "i" Protection by type of protection "n" Equipment with EPL "Ga" Optical radiation op is Protected by enclosures "t" (dust ignition protection) General requirements Protection by powder filling "q" Protection by increased safety "e" Protection by intrinsic safety "i" Protection by type of protection "n" Equipment with EPL "Ga" Optical radiation op is Protected by enclosures "t" (dust ignition protection) Dust-Ignitionproof Electrical Equipment General Requirements General requirements Protection by powder filling "q" Protection by increased safety "e" Protection by intrinsic safety "i" Protection by type of protection "n" Intrinsically safe electrical systems Equipment with EPL "Ga" Protected by enclosures "t" (dust ignition protection) OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 15 of 36
16 Electrical parameter 4 Electrical parameter 4.1 Intrinsically safe interfaces (Ex ia) X30 PB - power button X30: PB, power button (X30-1, X30-2) connected parallel, GND (X30-3, X30-4): Max. output voltage U o = 5.36 VDC Max. output current I o = 46 ma Max. output power P o = W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = 1 20 µh C o and L o pairs directly above / underneath each other may be used X31 - Fan X31: Fan power (X31-1), (X31-3) each circuit, GND (X31-2, X31-4): Max. output voltage U o = VDC Max. output current I o = 189 ma Max. output power P o = W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = µh C o and L o pairs directly above / underneath each other may be used. Page 16 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
17 Electrical parameter X32 - Barcode / reader Notes: For installation at X32 must be observed, that the connected device can be supplied either from the 10.4 V (X32-1) or the 5.36V (X32-2) power circuit. The terminals 1 and 2 shall NOT be connected at the same time! The terminal X32 includes one common terminal (X32-5) for the GND connection of the power and the data interfaces. When only one common GND wire from the cable of the connected device is used, then the total current must be observed for determination of external inductances! X32: Barcode / reader 10,4 V power (X32-1), GND (X32-5): Max. output voltage U o = 10.4 VDC Max. output current I o = 391 ma Max. output power P o = W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = µh C o and L o pairs directly above / underneath each other may be used. X32: Barcode / reader 5,36 V power (X32-2), GND (X32-5): Max. output voltage U o = 5.36 VDC Max. output current I o = 420 ma Max. output power P o = W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = 1 2 µh C o and L o pairs directly above / underneath each other may be used. X32: Barcode / reader data TXD (X32-3), RXD (X32-4) each circuit, GND (X32-5): Max. output voltage U o = between RxD and GND, resp. TxD and GND ±5.35 VDC between RxD and TxD ±10.70 VDC Effective internal capacitance C i = negligible Effective internal inductance L i = negligible Max. output current I o = 16 ma Max. output power P o = W Max. input voltage U i = ±12.5 VDC Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = 1 20 µh C o and L o pairs directly above / underneath each other may be used. Note: The external capacitances and inductances were calculated for the maximum voltage of 10.7 V. If only one of both signals RXD or TXD is connected, only a reduced voltage of 5.35 V has to be considered. Therewith, the following values are permissible: Max. external capacitance Co = µf Max. external inductance L o = 1 2 µh OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 17 of 36
18 Electrical parameter X33 / X34 - USB KB/M X33 / X34: USB KB/M terminals + (X33/34-1), D- (X33/34-2), D+ (X33/34-3), GND (X33/34-4): Max. output voltage U o = 5.36 VDC Max. output current I o = 249,85 ma Max. output power P o = 0,518 W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = 0,68 1,68 2,68 3,68 4,68 µh C o and L o pairs directly above / underneath each other may be used X35 - USB X35: USB terminals + (X35-1), D- (X35-2), D+ (X35-3), GND (X35-4): Max. output voltage U o = 5.36 VDC Max. output current I o = 1,264 A Max. output power P o = 2,949 W Trapezoidal output characteristics Max. external capacitance C o = µf Max. external inductance L o = 0,68 1,68 2,68 3,68 4,68 µh C o and L o pairs directly above / underneath each other may be used X36 / X37 - RF1 / RF2 X36 / X37: RF1 / RF2, type W02, W05, W22, W55, W25 each circuit: Radio frequency f o = 2.4 GHz 5 GHz Max. RF threshold power P o = 17 dbm (50 mw) It is responsible of the installer to ensure that the RF threshold power radiated from the antenna must be limited to max. 33 dbm (2 W) for Gas Group IIC. The calculation of this should take into account of output power of the interface and the gain of the antenna. It is permissible to consider losses in the cable in this calculation. Example of RF threshold power calculation: Output power of the interface X36 / X37 = 17 dbm (50 mw) Coaxial cable loss = 2 db Gain of the antenna = 5 dbi RF threshold power radiated from the antenna = 17 dbm 2 db + 5 dbi = 20 dbm (100 mw) 20 dbm (100 mw) < 33 dbm (2 W) so that the operation of this coaxial cable and antenna combination used in this example pass the requirements for use in Gas Group IIC. The antennas connected to the interface X36 / X37 must be installed in accordance with earthing requirements of IEC : 2014 clause or local installation codes (such as NEC or CEC). 4.2 Bluetooth - B1 Radio frequency f o = 2.4 GHz Max. RF threshold power P o = 33 dbm / 2 W Page 18 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
19 Electrical parameter 4.3 Reader interface RFID - RF1, RF2 Radio frequency for type RF1 f o = MHz Radio frequency for type RF2 f o = 2.4 GHz Max. RF threshold power P o = 33 dbm / 2 W 4.4 Inherently safe optical interfaces (Ex op is) X20 / X21 Fibre 1 / Fibre 2 type FX Wavelength = 1310 nm Nominal optical radiated power = mw Max. optical radiated power under fault conditions = 35 mw X20 / X21 Fibre 1 / Fibre 2 type SX Wavelength = 850 nm Nominal optical radiated power = 0.22 mw Max. optical radiated power under fault conditions = 35 mw X20 / X21 Fibre 1 / Fibre 2 type LX Wavelength = 1310 nm Nominal optical radiated power = 0.22 mw Max. optical radiated power under fault conditions = 35 mw X22 Fibre 3 type OSX Wavelength = 850 nm Nominal optical radiated power = 0.22 mw Max. optical radiated power under fault conditions = 35 mw X22 Fibre 3 type OLX Wavelength = 1310 nm Nominal optical radiated power = 0.22 mw Max. optical radiated power under fault conditions = 35 mw 4.5 Non intrinsically safe interfaces (Ex e / Ex na) X1 - Power Nominal voltage = for device variant AC = VAC for device variant DC = VDC Nominal current = for device variant AC = 5 A for device variant DC = 8 A Nominal power = 150 W Max. input voltage U m = 250 VAC X2 / X3 - copper1 / copper2 Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 19 of 36
20 Electrical parameter X4 - DC out Nominal voltage terminal 1 = 12 VDC Nominal voltage terminal 4 = 24 VDC Max. input voltage U m = 250 VAC X5 - CAN Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC X6 - USB Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC X7 - RSxxx Nominal voltage = 12 VAC / VDC Max. input voltage U m = 250 VAC X8 - DVI Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC X9 - Audio / Video Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC X10 - SATA Nominal voltage = 5 VAC / VDC Max. input voltage U m = 250 VAC Page 20 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
21 Electrical parameter 4.6 Connection overview terminal assignment Terminal Pin Definition (circuit board) / view Typical cable color / plug design Connection / function Ex e compartment / terminals X V / L Black Power supply of the POWER V / L Black HMI device 3 GND / N Blue (either AC or DC) 4 GND / N Blue 5 PE / Earth Green / Yellow 6 PE / Earth Green / Yellow X2 * 1000Base-TX 100Base-TX Data line CAT1 1 D1+ TX+ White / Orange Copper connection 1 2 D1- TX- Orange 3 D2+ RX+ White / Green 4 D2- RX- Green 5 D3+ White / Blue 6 D3- Blue 7 D4+ White / Brown 8 D4- Brown X3 * 1000Base-TX 100Base-TX Data line CAT2 1 D1+ TX+ White / Orange Copper connection 2 2 D1- TX- Orange 3 D2+ RX+ White / Green 4 D2- RX- Green 5 D3+ White / Blue 6 D3- Blue 7 D4+ White / Brown 8 D4- Brown X20 * SC Duplex Data line FO 1 jack FO connection 1 at SERIES 400 / 500 Type FX (100Base-FX) X21 * SC Duplex Data line FO 2 jack FO connection 2 at SERIES 400 / 500 Type FX (100Base-FX) NOTICE * Please note that the Ethernet connection is either for a copper connection or for an optical fibre connection (see order versions)! OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 21 of 36
22 Electrical parameter Terminal Pin Definition (circuit board) / view Typical cable color / plug design Connection / function Ex e compartment / terminals X V 12 and / or 24 V DC DC out 2 GND Output 3 GND max. load 500 ma V for each output X5 CAN 1 CAN1 L CAN-Bus connection 2 CAN1 H (Order option) 3 CAN2 L (not possible at 4 CAN2 H SERIES 500) (2 chanel) X6 1 +5V Red USB connection USB 2 D - White 3 D + Green 4 GND Black X7 RS-232 RS-422 RS-485 Serial interface RSxxx 1 TxD TxD-A A (COM) 2 RxD RxD-B RS-232 / RS-422 / RS RTS TxD-B B 4 CTS RxD-A 5 GND X8 1 D0- DVI connection DVI 2 D0+ 3 GND 4 D1-5 D1+ 6 GND 7 D2-8 D2+ 9 CLK- 10 CLK+ 11 GND 12 DDC Clock 13 DDC Data 14 GND 15 +5V 16 Hot Plug X9 Audio / Video connection Audio / 1 L out Line out left Video 2 R out Line out right 3 GND 4 Video Video input 5 GND (not possible at SERIES 400 / 500) Page 22 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
23 Electrical parameter Terminal Pin Definition (circuit board) / view Typical cable color / plug design Connection / function Ex i compartment / terminals X30 1 PB On / Off switch PB 2 GND connection 3 GND 4 GND X31 1 +FAN Fan connection FAN 2 GND 3 +FAN 4 GND X V Barcode- / card reader RS232 / V connection Power 3 GND 4 RxD 5 TxD X V Red USB connection USB 2 D - White 3 D + Green 4 GND Black X V Red USB connection USB 2 D - White 3 D + Green 4 GND Black X V Red USB connection USB 2 D - White (terminals or jack) 3 D + Green 4 GND Black USB jack Type A X36 X37 SMA-Reverse jack SMA-Reverse jack WLAN Antenna connection 1 (for 2.4 GHz antenna) WLAN Antenna connection 2 (for 5 GHz antenna) OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 23 of 36
24 Instructions for safety 5 Instructions for safety 5.1 Putting into service No special conditions. 5.2 Use See "intended use". 5.3 Assembling The device may be installed and operated in any position. The device must be mounted securely, using the threads or holes integrated into the enclosure or at the outer cooling fins of the display module. 5.4 Maintenance, overhaul and repair The devices are maintenance-free across their entire lifespan. System maintenance should focus on the following: a. Seal wear b. Display damage c. All screws are tightened fast d. All cables and lines are properly connected and undamaged The HMIs of the xx8 SERIES consist of a display module and an E-Box module which are mounted together. For service proposals these modules are interchangeable. All circuits must be de-energised for interchanging. The mounting torque of the screws form mounting the display and E-Box module together is 4 5 N. This screws are located under the covers of the connection compartments. The display and the E-Box module are not intended to be repaired by customers. WARNING Do not open! The enclosure has been permanently sealed and cannot be repaired. Do not open, maintain or service in an area where an explosive atmosphere may be present! For access into the connections of the E-Box, isolate supply and all Ex e / Ex na circuits, wait 5 minutes before opening the connection compartment! 5.5 Installation Details for connection compartments The cover of the connection compartments (Ex i / Ex e / Ex na) includes mounting options for associated equipment (e.g. cable glands, cable connectors, buttons). The associated equipment to be mounted in the cover of the connection compartments must pass IP66 rating and adhere to the relevant IEC, ANSI/UL or CSA C22.2 requirements. - for Ex e connection compartments the IEC, ANSI/UL or CSA C22.2 number for Ex i connection compartments the IEC, ANSI/UL or CSA C22.2 number for Ex na connection compartments the IEC, ANSI/UL or CSA C22.2 number The details of used associated equipment must be observed (for example permitted cable diameter for used cable glands, tighten rules, cable clamping). Page 24 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
25 Instructions for safety Country-specific regulations must be observed, in particular any possible changes in ambient parameters (e.g. ambient temperature range). Unused openings must be closed by a suitable blind plug. Threaded entries with tapered threads must be used with not less than 3 threads. Parallel threads must be used with a tolerance class of 6H or better and an additional seal or gasket. The mounting torque of the connection compartment cover screws is N Details for electrical connection of Interfaces X1... X9, X31 X35 Stripping length: Mounting torque: 7 mm N Connectable conductor cross section: - rigid [mm²] or (AWG): or (24 12) - flexible [mm²] or (AWG): or (24 12) Multi-conductor connection (two conductor with the same cross section and conductor type): - rigid [mm²] or (AWG): or (24 16) - flexible [mm²] or (AWG): or (24 *1) * Note: No direct equivalent AWG size listed in IEC Multi-conductor connection for X1 as screw terminal (two conductor with the same cross section and conductor type): - rigid [mm²] or (AWG): or (24 16) - flexible [mm²] or (AWG): or (24 18) The connectors are designed to be readily connected or disconnected without load. The device must be disconnected from the mains before assembly, maintenance, or repair. The connector fixing screws must be fitted. It is the responsibility of the installer to ensure the maximum rated current of 12 A for each contact of connector terminal X1. In case of screw terminals for X1 the maximum rated current of 16 A for each contact of X1 must be guaranteed. The maximum voltage of 250 V and a short current of 1500 A must not be exceeded at the place of installation. Connection to the device shall be done with copper wire rated for at least 90 C. Where the ambient temperature is expected to be greater than 60 C (to the rated maximum) the connections shall be done with copper wire rated for 105 C Details for electrical connection of Interface X10 The connector X10 is usable with manufacturers approved connectors / devices only. OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 25 of 36
26 Panel mounting with xx8 Mounting-Kit Earthing The devices must be earthed with a core cross section of at least 4 mm 2 or in line with applicable standards. An external earth connection facility is provided. 5.6 Adjustment n. A. 6 Panel mounting with xx8 Mounting-Kit The xx8 device can be mounted in an enclosure with suitable cut-out using an xx8 mounting frame kit (Mounting-Kit). This mounting kit is approved for mounting in an Ex e, Ex p or Ex tb protected enclosure. The xx8 mounting kit consist of sealing material and a mounting frame. The sealing material is applied at the rear side of the xx8 equipment. The mounting frame fixes the xx8 device in the cut out and is mounted from rear side. The assembly is shown in drawing Rev02 xx8 Mounting Assembly Overview. All screws of the mounting frame must be tightened with a torque of 1.5 Nm to 2 Nm. Page 26 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
27 Special conditions of use 7 Special conditions of use The intrinsically safe circuits are connected to earth. Along the intrinsically safe circuits, potential equalization must exist. For devices with wireless interface (characters W02, W05, W22, W55 or W25 in the type code): The maximum radio frequency power threshold at the antennas connected to the interfaces X36 and X37 shall not exceed the admissible value of 2 W for group IIC. The calculation of this should be taken into account the output power of the transmitter (X36 / X37), the gain of the antenna and the losses in the cable. The intrinsic safe circuits at X36 und X37 are connected to earth. The antennas connected to the interface must be installed in accordance with earthing requirements of EN , of National Electrical Code ANSI/NFPA 70 and of Canadian Electric Code CSA C22.1. The covers of the connection compartments are equipped with cable glands and blind plugs. Optionally they can be equipped with plugs and sockets and switches. This equipment has to fulfill IP66 and be separately certified for the respective type of protection. 8 Special tools n. A. 9 Cells and Batteries The internal battery is interchangeable by manufacturer only. OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 27 of 36
28 Drawings 10 Drawings Further drawings can be found in additional documents Panel mounting with xx8 Mounting-Kit Page 28 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
29 Control Drawing 11 Control Drawing 11.1 FM USA / Canada OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 29 of 36
30 Control Drawing Page 30 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
31 Control Drawing OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 31 of 36
32 Declaration of EC conformity 12 Declaration of EC conformity 12.1 ET-xx8 Page 32 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
33 Declaration of EC conformity 12.2 MT-xx8 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx / Page 33 of 36
34 Release notes 13 Release notes The chapter entitled "Release Notes" contains all the changes made in every version of the Instruction manual. Version Changing / correction "Device designation (includes)" at Panel PC Addition of Thin Client Ex OG Changing content "Intended use" Adaption of type code to variants OG Addition of "Device platform SHARK" Addition of information according to ATEX 1. Supplement Addition of information according to IECEx Issue No. 2 Changing HW-Revision at cover Changing type code value for reader interface Addition of type code at reader interface Changing ATEX direction 94/9/EG according to 2014/30/EU Changing Ex marking at Gas Addition of TR (EAC) certification Addition of FM certification USA and Canada Changing Conformity to standards Changing standard clause in section "Antenna earthing requirements" Addition of Warning "High Temperature" Addition of Control Drawing FM Addition of section "Panel mount with xx8 Mounting-Kit" Addition of drawing "Panel mount with xx8 Mounting-Kit" Addition of text according to "Control Drawing" in section "Intrinsically safe interfaces" Addition of "local installation codes NEC or CEC" in section "X36 / X37 - RF1 / RF2" Addition of section "Connection overview terminal assignment" Addition of warnings in section "Maintenance, overhaul and repair" Addition of section "Details for connection compartments" with FM standards Addition of sentences with "rated temperatures at copper wires" in section "Details for electrical connection of Interfaces X1... X9, X31 X35" Addition of pictures in section "Earthing" Addition of section "Special conditions of use" with FM standards Renew Declaration of EC conformity Removal of previous release notes Text-, layout- and formal corrections Page 34 of 36 OI_ET_MT-xx8_SIE_en_V_01_01_00.docx /
35
36 Siemens AG Division Digital Factory Postfach NÜRNBERG
Operating Manual. isolate501
Operating Manual isolate501 Document Number 413569 (See Last Page for Revision Details). Copyright Extronics Ltd, 2015 Page 2 of 21 Contents 1 Introduction... 4 2 Safety Information and Notes... 5 2.1
More informationSIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4
Characteristics 1 Ordering data 2 SIMATIC Ident RFID systems Operating Instructions Installing and mounting 3 Connecting the antenna 4 Antenna parameter assignment 5 Antenna patterns 6 Maximum read/write
More informationInstallation & Operating Manual. iwap202
Installation & Operating Manual iwap202 This page is intentionally left blank. Document Number 409345 (based on 407655) (See Last Page for Revision Details) For warranty information, refer to Terms and
More informationSolexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:
OVERVIEW The Solexy RX series explosion proof and intrinsically safe antenna coupler is an integrated protection device that facilitates non-ex certified radio antenna installation in hazardous areas.
More informationSIMATIC Ident RFID systems ANT 3 Compact Operating Instructions
SIMATIC Ident RFID systems Compact Operating Instructions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to
More informationDigital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC
Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC Properties 1 Parameters 2 Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) Manual
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING
More information2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes
More informationInstallation guide 873 SmartRadar Control Unit & Antenna Unit
Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl
More informationInstallation guide 971 SmartRadar LTi
Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl
More informationOPTIWAVE 7300 C Supplementary instructions
OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationSIMATIC RTLS. Localization systems SIMATIC RTLS PCB OEM AX (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01
SIMATIC RTLS Localization systems (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01 Legal information Warning notice system This manual contains notices you have to observe in order to ensure
More informationIntrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i
Intrinsically Safe Compact Controller CTR 210i Intrinsically Safe Bargraph Indicator BGI 210i DMT 02 ATEX E 148 2. Supplement also grahics display Revision 4 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.:
More informationSafety Manual. Omni-ID UHF Tags
Safety Manual Omni-ID UHF Tags This page is intentionally left blank. Document Number 330556 (See Last Page for Revision Details) 2012 Extronics Limited. This document is Copyright Extronics limited. Extronics
More informationBAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description
BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70163240 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, Bayern 63911 GERMANY Attention: Harald Gollas The products listed
More informationFieldbus Isolating Repeater Series 9185/11
www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationIsolators A3/1.
> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]
More informationIntrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications
More informationMid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL
Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.
More informationInstallation guide 877 FDI Field Display & Interface
Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com
More informationIsolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No
9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used
More informationSIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.
SIMATIC ET 200SP Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual Edition 02/2014 Answers for industry. DI 8xNAMUR HF digital input module (6ES7131-6TF00-0CA0) SIMATIC ET 200SP DI 8xNAMUR HF
More informationPressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751
060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions
More informationIntrinsic Safety Control Drawing
s Intrinsic Safety Control Drawing A5E00455287 system in total "No revision to drawing without prior Approval by FM Approvals!" PLC PC Non hazardous area PROFIBUS DP RS 485-IS Coupler PROFIBUS RS 485-IS
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More information[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011
Quick Installation Guide Temperature Transmitter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information Product Certifications End www.rosemount.com
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationInstallation guide 854 XTG Level Gauge
Installation guide 854 XTG Level Gauge July 2008 Part no. 4416.276 Rev. 5 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationLoop Powered Indicator
Instruction Manual Model PD686 Loop Powered Indicator M397 January 3, 2019 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Tel: 978-486-9800 Fax: 978-486-0170 PD686 I.S. and N.I. NEMA 4X, IP67
More informationIntrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,
More informationRudder or propeller angular position transmitter KINAX WT720
Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationM224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #
Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationiant101 Zone 1 Omni Directional Antenna
iant101 Zone 1 Omni Directional Antenna External Antenna offering increased flexibility for positioning and greatly enhanced RF Propagation. ATEX Ex t IIIC T85 C Db IECEx Ex t IIIC T85 C Db -40 C to 60
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationSafety Instructions Proline Promass 100
XA00160D/06/EN/03.14 71261250 Products Solutions Services Safety Instructions Proline Promass 100 Modbus RS485 Cl.I Div.1, Zone 1 for IS (Ex i Intrinsically safe version) C US Document: XA00160D Safety
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationFM Safety Manual. Omni-ID UHF Tags
FM Safety Manual Omni-ID UHF Tags This page is intentionally left blank. Document Number 334169 (See Last Page for Revision Details) 2012 Extronics Limited. This document is Copyright Extronics limited.
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More informationAdjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**
Assembly Instructions for: PL ** Series Junction Boxes AI 23 / Issue W - 01/ IMPORTANT: This document should be read carefully before commencing installation Zones of Use of Box CAT II 2G for use in Zone
More informationInstallation guide 970 SmartRadar ATi
Installation guide 970 SmartRadar ATi July 2008 Part no. 4416.717 Rev. 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com Website
More informationUser's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R
User's Manual ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 Table of contents Table of contents
More informationSafety Instructions Proline Promass 300
XA01507D/06/EN/01.16 71327925 Products Solutions Services Safety Instructions Proline Promass 300 Class I, Zone 2 AEx/Ex na ic IIC Class I, Zone 2, AEx/Ex na nc ic IIC Class I Division 2 C US Document:
More informationCoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter
Operating Instruction OI/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter Measurement made easy Change from one to two columns Short product description Coriolis
More informationInstallation guide 970, 971 and 973 series SmartRadar
Installation guide 970, 971 and 973 series SmartRadar August 2008 Part no. 4416.719 Rev. 1 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com
More informationFLEX Ex V ac In/Quad-Ex dc Out Power Supply
Installation Instructions FLEX Ex 85 250V ac In/Quad-Ex dc Out Power Supply Catalog Number 1797-PS1N Topic Important User Information 2 About the Power Supplies 3 Understand System Planning 4 Electrostatic
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationAdjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**
Assembly Instructions for: PL ** Series Junction Boxes IMPORTANT: This document should be read carefully before commencing installation Zones of Use for Box - as defined in IEC/EN 00-0 and IEC/EN 00--1
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationRemote I/O. 74 Remote I/O. Remote I/O System
System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU
More informationIsolating Repeater Input Series 9163
> For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de
More informationInductive sensor slot-type SI2-K08-AP7
SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type
More informationExternal brake resistor AX2090-BW5x
Documentation External brake resistor AX2090-BW5x Accessories for Beckhoff servo drive AX5000 Version: Date: 1.3 2018-03-14 Table of content Table of content 1 Foreword... 5 1.1 Notes on the documentation...
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationiant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas
iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas This page is intentionally left blank. Document Number 403449
More informationSET Installation and Operating Instructions. Level switch for two sensors
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 20.2.2013 Internet: www.labkotec.fi 1/14 SET-2000 Level switch for two sensors Copyright 2013 Labkotec
More informationSIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.
SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation
More informationSINAMICS drives. SINAMICS DCM as a DC voltage source. Application. Answers for industry. Edition 01/2014
SINAMICS drives SINAMICS DCM as a DC voltage source Application Edition 01/2014 Answers for industry. Compact User Manual Legal information Warning notice system This manual contains notices you have to
More informationRadio Control Installation and Operating Instructions System 4
Radio Control Installation and Operating Instructions System 4 P.O. Box 403, One Cedar Parkway, Jackson, WI 53037 Phone: 800-628-1909 Fax: 262-677-2058 Revision: April 19, 2012 Contents Introduction 3
More informationDigital Input Output Module for Zone 1 Series 9470/32
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationMicro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc
IECEx Installation Instructions EB-20025744 Rev. AC December 2015 Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc 5700 IECEx Installation Instructions EB-20025744
More informationC-Bus 8 Channel Low Voltage Relay
SLC5108RELVP Instruction Bulletin Retain for future use. 63249-420-325A1 Instruction Bulletin 07/2009 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to
More informationInstallation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters
Installation Instructions P/N MMI-20011709, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters Note: For hazardous installations in Europe, refer to standard EN
More informationRX Series UL Listed Explosion Proof Antenna Coupler For Hazardous Area Applications Installation & Operation Manual (IOM)
OVERVIEW The Solexy RX explosion proof antenna coupler is an integrated protection device that facilitates radio antenna installation in hazardous areas. The patented (7,057,577) RX coupler features a
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160
Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationSITRANS TH200/TH300 SITRANS T. Temperature transmitter SITRANS TH200/TH300. Introduction 1. General safety notes. Description 3.
Introduction 1 General safety notes 2 SITRANS T Temperature transmitter Operating Instructions Description 3 Installation 4 Connecting 5 Operation 6 Functional safety 7 Commissioning 8 Functions 9 Service
More informationWireless Base Radio. Wireless Transmitters
XYR 5000 Wireless Base Radio 34-XY-03-55 9/2006 WBR/WBH Europe PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The Wireless Base Radio (WBR) is part of the XYR 5000 family of wireless products.
More informationIndustrial Pressure Transducers
Industrial Pressure Transducers User s Manual T Model T Model The Swagelok T model transducer is engineered for use in industrial pressure measurement applications where intrinsically safe ratings are
More information1-830 SERIES DISPLACEMENT TRANSMITTER
1-830 SERIES DISPLACEMENT TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com
More informationMODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationRAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description
RAD-IN/OUT-D Digital extension modules for the bidirectional wireless system INTERFACE Data sheet 102122_en_0 PHOENIX CONTACT 2010-02-2 1 Description The RAD-ISM-...-SET-BD-BUS-ANT bidirectional wireless
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationD1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater
DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus
More informationDANGER indicates that death or severe personal injury will result if proper precautions are not taken.
Introduction 1 General safety notes 2 SITRANS Temperature transmitter Operating Instructions Description 3 Installation 4 Connecting 5 Operation 6 Functional safety 7 Commissioning 8 Functions 9 Service
More informationSafety Instructions Proline Promag 500
XA01524D/06/EN/01.16 71327947 Products Solutions Services Safety Instructions Proline Promag 500 Cl.I, II, III Div.1 for XP (Ex d Flameproofed version) C US Document: XA01524D Safety instructions for electrical
More informationMACX MCR-EX-SL-RPSSI-I-UP(-SP)
Supply and input signal conditioner, Ex-i, with wide range supply Data sheet 103561_en_00 PHOENIX CONTACT 2014-08-19 1 Description The MACX MCR-EX-SL-RPSSI-I-UP(-SP) repeater power supply and input signal
More informationSITRANS TH200/TH300 SITRANS T. Temperature transmitter SITRANS TH200/TH300. Introduction 1. Safety information. Description.
Introduction 1 Safety information 2 SITRANS T Temperature transmitter Operating Instructions Description 3 Installation 4 Connecting 5 Operation 6 Functional safety 7 Commissioning 8 Functions 9 Technical
More informationEx instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,
Ex instruction manual Rotamass Coriolis mass flow meter IM 01U10X02-00EN-R_002, 2nd edition, 2016-09-22 Table of contents Table of contents 1 Introduction... 4 1.1 Scope of application... 4 1.2 Applicable
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationSINVERT. Technical requirements for medium-voltage transformers for use with SINVERT central inverters. Application manual 04/2012
Technical requirements for medium-voltage transformers for use with SINVERT central inverters Application manual 04/2012 SINVERT Answers for the environment. Technical requirements for medium- Technical
More informationInstallation Instructions
SYSTXBBSAM01 EVOLUTION SYSTEM ACCESS MODULE Installation Instructions NOTE: Read the entire instruction manual before starting the installation. pointsett U.S. Pat No. 7,415,102 Fig. 1 - Evolution System
More informationMINI MCR-SL-UI-I-LP-NC
2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More information