Safety Instructions Proline Promass 300
|
|
- Austin Ryan
- 6 years ago
- Views:
Transcription
1 XA01507D/06/EN/ Products Solutions Services Safety Instructions Proline Promass 300 Class I, Zone 2 AEx/Ex na ic IIC Class I, Zone 2, AEx/Ex na nc ic IIC Class I Division 2 C US Document: XA01507D Safety instructions for electrical apparatus for explosionhazardous areas classified according to the National Electrical Code (NEC) and Canadian Electrical Code (CEC) 3
2
3 Proline Promass 300 XA01507D Proline Promass 300 Table of contents Associated documentation... 4 Manufacturer's certificates... 5 Extended order code... 5 Safety instructions: General... 8 Safety instructions: Installation... 8 Temperature tables... 9 Connection data: Signal circuits Endress+Hauser 3
4 XA01507D Proline Promass 300 Associated documentation All documentation is available: On the CD-ROM supplied (not included in the delivery for all device versions). Available for all device versions via: Internet: Smart phone/tablet: Endress+Hauser Operations App In the Download Area of the Endress+Hauser web site: Download This document is an integral part of the following Operating Instructions: Measuring device Documentation HART FOUNDATION Fieldbus PROFIBUS PA Modbus RS485 Promass A 300 BA01482D BA01515D BA01504D BA01493D Promass E 300 BA01484D BA01517D BA01506D BA01495D Promass F 300 BA01485D BA01518D BA01507D BA01496D Promass H 300 BA01486D BA01519D BA01508D BA01497D Promass I 300 BA01487D BA01520D BA01509D BA01498D Promass O 300 BA01488D BA01521D BA01510D BA01499D Promass P 300 BA01489D BA01522D BA01511D BA01500D Promass Q 300 BA01490D BA01523D BA01512D BA01501D Promass S 300 BA01491D BA01524D BA01513D BA01502D Promass X 300 BA01492D BA01525D BA01514D BA01503D Additional documentation: Document type Contents Documentation code Special documentation Safety instructions Control drawing Remote display and operating module DKX001 Remote display and operating module DKX001: Class I, Zone 2, Class I Division 2 SD01763D XA01513D As wanted on the nameplate. Please note the documentation associated with the device. 4 Endress+Hauser
5 Proline Promass 300 XA01507D Manufacturer's certificates Certificate number CSA Notified body CSA: Canadian Standards Association Extended order code The extended order code is indicated on the nameplate, which is affixed to the device in such a way that it is clearly visible. Additional information about the nameplate is provided in the associated Operating Instructions. Structure of the extended order code * * * * * * _ * * * * * * * * * * + A*B*C*D*E*F*G* Device type Basic specifications Optional specifications * = Spaceholder: At this position, an option (number or letter) selected from the specification is displayed instead of the placeholders. Device type The device and the device design is defined in the "Device type" section (Product root). Basic specifications The features that are absolutely essential for the device (mandatory features) are specified in the basic specifications. The number of positions depends on the number of features available. The selected option of a feature can consist of several positions. Optional specifications The optional specifications describe additional features for the device (optional features). The number of positions depends on the number of features available. The features have a 2-digit structure to aid identification (e.g. JA). The first digit (ID) stands for the feature group and consists of a number or a letter (e.g. J = test, certificate). The second digit constitutes the value that stands for the feature within the group (e.g. A = 3.1 material (wetted parts), inspection certificate). More detailed information about the device is provided in the following tables. These tables describe the individual positions and IDs in the extended order code which are relevant to hazardous locations. Endress+Hauser 5
6 XA01507D Proline Promass 300 Device type Item Order code for Selected option Description 1 Instrument family 8 Coriolis flowmeter 2 Sensor A, E, F, H, I, O, P, Q, S, X Sensor type 3 Transmitter 3 Transmitter type: 4-wire, compact version 4 Generation index B Platform generation 5, 6 Nominal diameter 1 to 350 1: 01 2: 02 to 350: 3E, 3F, 3R Nominal diameter of sensor Basic specifications Position 1, 2 Order code for "Approval" Option selected Type of protection Transmitter Sensor CS Cl.I, Div.2, Gps. A-D Cl.I, Div.2, Gps. A-D CZ Cl.I, Zone 2, AEx/Ex na nc IIC... Gc 1) Cl.I, Zone 2, AEx/Ex na IIC... Gc Cl.I, Zone 2, AEx/Ex na nc IIC... Gc 2) 1) The marking Ex na nc [ic] IIC Gc is only available for devices with order code "Output; Input 1", option HA or TA 2) The marking Ex na nc is only applicable for sensor versions without purge connection or rupture disk. Position Order code for Option selected Description 4, 5 Output, input 1 BA 4-20mA HART GA HA MA SA TA PROFIBUS PA PROFIBUS PA Ex-i Modbus RS485 FOUNDATION Fieldbus FOUNDATION Fieldbus Ex-i 6 Output, input 2 A W/o; B C D E F 4-20mA 4-20mA Ex-i Configurable I/O initial setting off Pulse/freq./switch output Pulse output, phase-shifted 6 Endress+Hauser
7 Proline Promass 300 XA01507D Position Order code for Option selected Description G H I J Pulse/freq./switch output Ex-i Relay 4-20mA input Status input 7 Output, input 3 A W/o; B C D E F G H I J 4-20mA 4-20mA Ex-i Configurable I/O initial setting off Pulse/freq./switch output Pulse output, phase-shifted Pulse/freq./switch output Ex-i Relay 4-20mA input Status input 8 Display, Operation A W/o; via communication F G 4-line, illuminated; touch control 4-line, illuminated; touch control + WLAN 17, 18 Device model A1 1 M W/o; prepared for remote display DKX001 1) O Separate, with remote display DKX001 1), 4-line, illuminated; 10m/ 30ft cable; touch control 1) DKX001 is approved according to CSA Optional specifications ID Order code for Option selected Description Jx Test, Certificate JP Ambient temperature of measuring device 50 C Cx Sensor option CA Rupture disk Cx Sensor option CH Rinse connection Endress+Hauser 7
8 XA01507D Proline Promass 300 Safety instructions: General Staff must meet the following conditions for mounting, electrical installation, commissioning and maintenance of the device: Be suitably qualified for their role and the tasks they perform. Be trained in explosion protection. Be familiar with national regulations (e.g. CEC or NEC). Install the device according to the manufacturer's instructions and national regulations. Do not operate the device outside the specified electrical, thermal and mechanical parameters. Only use the device in media to which the wetted materials have sufficient durability. Refer to the temperature tables for the relationship between the permitted ambient temperature for the sensor and/or transmitter, depending on the range of application, and the temperature classes. Modifications to the device can affect the explosion protection and must be carried out by staff authorized to perform such work by Endress+Hauser. Observe all the technical data of the device (see nameplate). LWARNING Substitution of components is not permitted. Substitution of components may impair suitability for Class I, Division 2. Safety instructions: Installation In the event of potentially explosive vapor/air mixtures, only operate the device under atmospheric conditions. Temperature: 20 to +60 C Pressure: 80 to 110 kpa (0.8 to 1.1 bar) Air with normal oxygen content, usually 21 % (V/V) If no potentially explosive mixtures are present, or if additional protective measures have been taken, the device may also be operated under non-atmospheric conditions in accordance with the manufacturer's specifications. 8 Endress+Hauser
9 Proline Promass 300 XA01507D Continuous service temperature of the connecting cable: 40 to +80 C ( 50 to +80 C for optional specification, ID Jx (Test, Certificate) = JP); but at least according to the service temperature range of the application taking into account additional influences of the process conditions (,min and,max + 20 K). Only use certified cable entries suitable for the application. Observe selection criteria as per CEC or NEC. When the measuring device is connected, attention must be paid to explosion protection at the transmitter. In potentially explosive atmospheres: Do not disconnect the electrical connection of the power supply circuit when energized. Do not open the connection compartment cover when energized. Install the transmitter circuit wiring according to Canadian Electrical Code (CEC) respective National Electrical Code (NEC) using threaded conduit or other wiring methods in accordance with articles 500 to 510. AEx/Ex na type of protection In potentially explosive atmospheres: Do not disconnect the electrical connection of the power supply circuit. Seal unused entry glands with approved sealing plugs that correspond to the type of protection. The plastic transport sealing plug does not meet this requirement and must therefore be replaced during installation. Only use certified cable entries or sealing plugs. The metal sealing plugs supplied meet this requirement. When operating in Zone 2 type of protection AEx/Ex na: Ensure that temporary interference does not cause the maximum operating voltage to be exceeded by more than 40 % (see nameplate). Intrinsic safety Observe the guidelines for interconnecting intrinsically safe circuits (e.g., Proof of Intrinsic Safety). Potential equalization Integrate the device into the local potential equalization. If the ground connection has been established via the pipe as specified, it is also possible to integrate the sensor into the potential equalization system via the pipe. Temperature tables Ambient temperature Minimum ambient temperature: = 40 C Endress+Hauser 9
10 XA01507D Proline Promass 300 Maximum ambient temperature: = +60 C depending on the medium temperature and temperature class Medium temperature Minimum medium temperature: Promass A, F, H, I, P, Q, S, X: T m = 50 C Promass E, O: T m = 40 C Promass F, Q with cryogenic temperature version (order code for "Measuring tube material", Option LA): T m = 200 C Maximum medium temperature: T m for depending on the maximum ambient temperature ( ) = The maximum permitted medium temperatures in brackets only apply if the sensor is installed in such a way that the transmitter is not mounted above the sensor and free convection can occur on all sides. Promass A Compact version Without thermal insulation T m ) ) ) ) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 195 C Promass E T m ) 115 2) ) (115 2) ) (140 3) ) (150) (150) ) 95 2) 140 3) Endress+Hauser
11 Proline Promass 300 XA01507D T m ) 140 3) (95 2) ) (140 3) ) (150) (150) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 150 C Promass F 1) T m ) 80 3) 115 4) ) ) 115 4) 170 5) ) 170 5) ) (240) 170 (240) ) 60 3) 95 4) ) ) 95 4) 160 5) ) 160 5) ) 150 6) 170 (240) 170 (240) ) 120 4) 185 5) 280 7) ) 185 5) 280 7) ) 60 3) 95 4) ) ) 95 4) 160 5) Endress+Hauser 11
12 XA01507D Proline Promass 300 1) T m ) 160 5) ) 160 6) 170 (240) 170 (240) 1) Maximum temperature range see nameplate 2) Cryogenic temperature version: T m = C 3) For sensors with type of protection Ex na nc applies: T m = 95 C 4) For sensors with type of protection Ex na nc applies: T m = 130 C 5) For sensors with type of protection Ex na nc applies: T m = 195 C 6) For sensors with type of protection Ex na nc applies: T m = 170 C 7) For sensors with type of protection Ex na nc applies: T m = 290 C Promass H T m ) 80 2) 115 3) ) ) 80 2) 115 3) 165 5) ) 165 5) ) 60 2) 95 3) 130 6) ) 130 6) ) 60 2) 95 3) 130 5) ) 130 5) ) Measuring tube material tantalum 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) Measuring tube material zirconium 5) For sensors with type of protection Ex na nc applies: T m = 195 C 6) For sensors with type of protection Ex na nc applies: T m = 150 C 12 Endress+Hauser
13 Proline Promass 300 XA01507D Promass I T m ) 95 2) ) (95 2) ) (150) (150) (150) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C Promass O T m ) 95 2) 160 3) ) 160 3) ) 160 4) 180 (205) 180 (205) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 195 C 4) For sensors with type of protection Ex na nc applies: T m = 180 C Promass P 1) T m ) 115 3) ) ) 115 3) 170 4) ) 170 4) ) 95 3) ) Endress+Hauser 13
14 XA01507D Proline Promass 300 1) T m ) 95 3) 160 4) ) 160 4) ) Maximum temperature range see nameplate 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) For sensors with type of protection Ex na nc applies: T m = 195 C Promass Q 1) T m ) 95 3) 160 4) ) 160 4) ) 60 2) 95 3) ) ) Maximum temperature range see nameplate 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) For sensors with type of protection Ex na nc applies: T m = 195 C 5) Cryogenic temperature version: T m = C Promass S T m ) 115 2) ) ) 95 2) ) ) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 14 Endress+Hauser
15 Proline Promass 300 XA01507D Promass X T m ) 95 2) 160 3) ) 160 3) (95 2) ) (160 3) ) (180) (180) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 180 C Promass A With thermal insulation according to Endress+Hauser specifications For information on the thermal insulation of the device, see the "Thermal insulation" section of the "Technical Information" document T m ) ) (130) (170 2) ) (205) (205) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 195 C Promass E T m ) 115 2) (115 2) ) (140 3) ) (150) (150) ) 95 2) 140 3) (95 2) ) (140 3) ) (150) (150) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 150 C Endress+Hauser 15
16 XA01507D Proline Promass 300 Promass F 1) T m ) 80 3) 115 4) (115 4) ) (150) (150) (150) ) 115 4) 170 5) (115 4) ) (170 5) ) (240) (240) ) 60 3) 95 4) (95 4) ) (160 5) ) (240) (240) ) 95 4) 160 5) (95 4) ) (160 5) ) (240) (240) ) 120 4) 185 5) 280 6) ) 185 5) 280 6) ) 60 3) 95 4) (95 4) ) (160 5) ) (240) (240) ) 95 4) 160 5) (95 4) ) (160 5) ) (240) (240) 1) Maximum temperature range see nameplate 2) Cryogenic temperature version: T m = C 3) For sensors with type of protection Ex na nc applies: T m = 95 C 4) For sensors with type of protection Ex na nc applies: T m = 130 C 5) For sensors with type of protection Ex na nc applies: T m = 195 C 6) For sensors with type of protection Ex na nc applies: T m = 290 C Promass H T m ) 80 2) 115 3) (115 3) ) (150) (150) (150) ) 80 2) 115 3) 165 5) (115 3) ) (165 5) ) (205) (205) ) 60 2) 95 3) 130 6) (95 3) ) (130) (150) (150) 16 Endress+Hauser
17 Proline Promass 300 XA01507D T m ) 60 2) 95 3) 130 5) (95) (130) (205) (205) 1) Measuring tube material tantalum 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) Measuring tube material zirconium 5) For sensors with type of protection Ex na nc applies: T m = 195 C 6) For sensors with type of protection Ex na nc applies: T m = 150 C Promass I T m ) 95 2) (95 2) ) (150) (150) (150) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C Promass O T m ) 95 2) 160 3) (95 2) ) (160 3) ) (205) (205) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 195 C Promass P 1) T m ) 115 3) (115) (150) (150) (150) ) 115 3) 170 4) Endress+Hauser 17
18 XA01507D Proline Promass 300 1) T m 55 (115 3) ) (170 4) ) (205) (205) ) 95 3) ) (95 3) ) (150) (150) (150) ) 95 3) 160 4) ) 160 4) (95 3) ) (160 4) ) (205) (205) 1) Maximum temperature range see nameplate 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) For sensors with type of protection Ex na nc applies: T m = 195 C Promass Q 1) T m ) 95 3) 160 4) (40) (95) (160) (205) (205) ) 60 2) 95 3) (40) (95) (150) (150) (150) 1) Maximum temperature range see nameplate 2) For sensors with type of protection Ex na nc applies: T m = 95 C 3) For sensors with type of protection Ex na nc applies: T m = 130 C 4) For sensors with type of protection Ex na nc applies: T m = 195 C 5) Cryogenic temperature version: T m = C Promass S T m ) 115 2) (115) (150) (150) (150) ) 95 2) Endress+Hauser
19 Proline Promass 300 XA01507D T m ) (95 2) ) (150) (150) (150) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C Promass X T m ) 95 2) 160 3) (95 2) ) (160 3) ) (180) (180) 1) For sensors with type of protection Ex na nc applies: T m = 95 C 2) For sensors with type of protection Ex na nc applies: T m = 130 C 3) For sensors with type of protection Ex na nc applies: T m = 180 C With thermal insulation without Endress+Hauser specifications 1 A B 1 Position of the reference point for temperature measurement A Standard version B Extended temperature version, cryogenic temperature version, hightemperature version 1 Reference point A Endress+Hauser 19
20 XA01507D Proline Promass 300 T m Endress+Hauser
21 Proline Promass 300 XA01507D Connection data: Signal circuits The following tables contain specifications which are dependent on the transmitter type and its input and output assignment. Compare the following specifications with those on the nameplate of the transmitter. Terminal assignment Transmitter: supply voltage, input/outputs HART Supply voltage Input/output 1 Input/output 2 Input/output 3 1 (+) 2 ( ) 26 (+) 27 ( ) 24 (+) 25 ( ) 22 (+) 23 ( ) Device-specific terminal assignment: adhesive label in terminal cover. FOUNDATION Fieldbus Supply voltage Input/output 1 Input/output 2 Input/output 3 1 (+) 2 ( ) 26 (A) 27 (B) 24 (+) 25 ( ) 22 (+) 23 ( ) Device-specific terminal assignment: adhesive label in terminal cover. PROFIBUS PA Supply voltage Input/output 1 Input/output 2 Input/output 3 1 (+) 2 ( ) 26 (B) 27 (A) 24 (+) 25 ( ) 22 (+) 23 ( ) Device-specific terminal assignment: adhesive label in terminal cover. Modbus RS485 Supply voltage Input/output 1 Input/output 2 Input/output 3 1 (+) 2 ( ) 26 (B) 27 (A) 24 (+) 25 ( ) 22 (+) 23 ( ) Device-specific terminal assignment: adhesive label in terminal cover. Endress+Hauser 21
22 XA01507D Proline Promass 300 Remote display and operating module DKX001 1 Vcc Gnd A 83 B Vcc Gnd A B A Remote display and operating module DKX001 2 Connecting cable 3 Measuring device Safety-related values Order code for "Output; input 1" Option BA Output type Current output 4 to 20 ma HART U N = 30 V U M = 250 V Safety-related values "Output; input 1" 26 (+) 27 ( ) Option GA PROFIBUS PA U N = 32 V U M = 250 V Option MA Modbus RS485 U N = 30 V U M = 250 V Option SA FOUNDATION Fieldbus U N = 32 V U M = 250 V Order code for "Output; input 2"; "Output; input 3" Option B Option D Output type Current output 4 to 20 ma User configurable input/output Safety-related values Output; input 2 Output; input 3 24 (+) 25 ( ) 22 (+) 23 ( ) U N = 30 V U M = 250 V U N = 30 V U M = 250 V 22 Endress+Hauser
23 Proline Promass 300 XA01507D Order code for "Output; input 2"; "Output; input 3" Option E Output type Pulse/frequency/ switch output Safety-related values Output; input 2 Output; input 3 24 (+) 25 ( ) 22 (+) 23 ( ) U N = 30 V U M = 250 V Option F Double pulse output U N = 30 V U M = 250 V Option H Relay output U N = 30 V I N = 100 ma DC/500 ma AC U M = 250 V Option I Current input 4 to 20 ma U N = 30 V U M = 250 V Option J Status input U N = 30 V U M = 250 V Intrinsically safe or NIFW values Order code for "Output; input 1" Output type Intrinsically safe or NIFW values "Output; input 1" 26 (+) 27 ( ) Option HA PROFIBUS PA Ex i AEx ic, Ex ic, NIFW U i = 32 V l i = 570 ma P i = 8.5 W L i = 10 µh C i = 5 nf Option TA FOUNDATION Fieldbus Ex i AEx ic, Ex ic, NIFW U i = 32 V l i = 570 ma P i = 8.5 W L i = 10 µh C i = 5 nf Endress+Hauser 23
24 XA01507D Proline Promass 300 Order code for "Output; input 2"; "Output; input 3" Output type Intrinsically safe or NIFW values Output; input 2 Output; input 3 24 (+) 25 ( ) 22 (+) 23 ( ) Option C Current output 4-20 ma Ex i U i = 30 V l i = 100 ma P i = 1.25 W L i = 0 C i = 0 Option G Pulse/frequency/ switch output Ex i U i = 30 V l i = 100 ma P i = 1.25 W L i = 0 C i = 0 Remote display DKX001 Basic specification, position 1, 2 Approval Terminal assignment Basic specification, position 8 Display; Operation Option O Option CS, CZ 81, 82, 83, 84 U n = 3.3 V I n = 150 ma 24 Endress+Hauser
25
26
27
28
Safety Instructions Proline Promag 500
XA01524D/06/EN/01.16 71327947 Products Solutions Services Safety Instructions Proline Promag 500 Cl.I, II, III Div.1 for XP (Ex d Flameproofed version) C US Document: XA01524D Safety instructions for electrical
More informationSafety Instructions Proline Promass 100
XA00160D/06/EN/03.14 71261250 Products Solutions Services Safety Instructions Proline Promass 100 Modbus RS485 Cl.I Div.1, Zone 1 for IS (Ex i Intrinsically safe version) C US Document: XA00160D Safety
More informationProline Promass 83, 84
Safety Instructions Proline Promass 83, 84 NEPSI Zone 1, Zone 21 This document is an integral part of the following Operating Instructions: BA00059D, Proline Promass 83 BA00109D, Proline Promass 84 BA00063D,
More informationProline Promass 40. Safety Instructions. NEPSI Zone 1, Zone 21
Safety Instructions Proline Promass 40 NEPSI Zone 1, Zone 21 This document is an integral part of the following Operating Instructions: BA00061D, Proline Promass 40 HART Contents General warnings.......................................................................
More informationPower supply. Calibration. Surface finishing. Seal. Process connection
Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst
More informationSafety Instructions Micropilot NMR81, NMR84
XA0436G-A/00/EN/0.6 733528 Products Solutions Services Safety Instructions NMR8, NMR84 CA: XP / I / / B,C,D / Tx Ta* IS / I / / A,B,C,D / Tx Ta* I / / Ex db IIC Tx Gb Ta* I / 0 / Ex ia IIC Tx Ga Ta* I
More informationPROline promag 53 Division 1
XA 040D/06/en/05.01 50099923 FM+SGML 6.0 PROline promag 53 Division 1 Ex Ex documentation for the BA 053D and BA 054D operating instructions according to FACTORY MUTUAL standards documentation for the
More informationFM Control Drawing Class I Division 2 / Class I Zone 2. Compact version PROMAG 10
Hazardous Locations Class I Div. 2 Groups ABCD or Class I Zone 2 Groups IIC and Class II and III Division 1 Groups EFG W / P / E / H / D / L Notes: 1. Control room equipment shall not use or generate more
More informationSafety Instructions Nivotester FTC625, FTC325
XA01351F-A/00/EN/01.14 71273077 Products Solutions Services Safety Instructions FTC625, FTC325 [Ex ia Ga] IIC/IIB TÜV 13.0903 X Segurança TÜV INMETRO OCP 0004 Document: XA01351F-A Safety instructions for
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationUser's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R
User's Manual ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 Table of contents Table of contents
More informationEx instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,
Ex instruction manual Rotamass Coriolis mass flow meter IM 01U10X02-00EN-R_002, 2nd edition, 2016-09-22 Table of contents Table of contents 1 Introduction... 4 1.1 Scope of application... 4 1.2 Applicable
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationOPTIWAVE 7300 C Supplementary instructions
OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General
More informationProcessMaster, HygienicMaster FEX300, FEX500
SM/FEX300/FEX500/FM/CSA-EN ProcessMaster, HygienicMaster FEX300, FEX500 FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual
More informationEx instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,
Ex instruction manual Rotamass Coriolis mass flow meter ATEX IM 01U10X01-00EN-R_002, 2nd edition, 2016-09-22 Table of contents Table of contents 1 Language variants of ATEX documentation... 4 2 Introduction...
More informationAttachment to Certificate IECEx PTB X
Applicant: Electrical Apparatus: KROHNE Ltd. Measuring converter, type MFC400F Description of equipment The measuring converter, type MFC400F is used as part of a mass flow measuring system to determine
More informationFM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationATEX Installation Drawings and Instructions
Installation Instructions P/N 20004414, Rev. C September 2008 ATEX Installation Drawings and Instructions For ATEX-approved transmitter installations Note: For hazardous installations in Europe, refer
More informationFLEX Ex V ac In/Quad-Ex dc Out Power Supply
Installation Instructions FLEX Ex 85 250V ac In/Quad-Ex dc Out Power Supply Catalog Number 1797-PS1N Topic Important User Information 2 About the Power Supplies 3 Understand System Planning 4 Electrostatic
More information2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationFLEX Ex Power Supplies
Installation Instructions FLEX Ex Power Supplies (Cat. Nos. 1797-PS2N, -PS2E) About the Power Supplies The power supply is an essential component in the operation of an intrinsically safe system. It must
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationCoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter
Operating Instruction OI/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter Measurement made easy Change from one to two columns Short product description Coriolis
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationProcessMaster / HygienicMaster
SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual Standards
More informationEngineering Guideline. pac-carriers Type for Yokogawa Centum VP
Engineering Guideline pac-carriers Type 9195 for Yokogawa Centum VP pac-carrier Type 9195 2 Engineering Guideline / Yokogawa Centum VP 26.0.2018 pac-carrier Type 9195 Integrated solutions for Yokogawa
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT
More informationRosemount 5408 and 5408:SIS Level Transmitters
Quick Start Guide 00825-0100-4408, Rev AD March 2018 Rosemount 5408 and 5408:SIS Level Transmitters Cone Antenna Quick Start Guide March 2018 1 About this guide This Quick Start Guide provides basic guidelines
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationSpecial Documentation Levelflex FMP51, FMP52, FMP55, FMP57
SD01328F/00/EN/02.14 71267123 Products Solutions Services Special Documentation Levelflex FMP51, FMP52, FMP55, FMP57 Guided Level Radar Installation and operating instructions for marine approval Levelflex
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationRosemount 5400 Series Radar Level Transmitter
Radar Level Transmitter Start Step 1: Mount the Transmitter Step 2: Connect the Wiring Step 3: Configure Confirm Configuration End HART 00825-0100-4026I www.rosemount.com 2007 Rosemount Inc. All rights
More informationDPharp Differential Pressure and Pressure Transmitters
User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationExpert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters
Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING
More informationMicro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc
IECEx Installation Instructions EB-20025744 Rev. AC December 2015 Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc 5700 IECEx Installation Instructions EB-20025744
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers
Instruction Manual Supplement DVC6005 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Hazardous Area Approvals and Special Instructions
More informationIndustrial Pressure Transducers
Industrial Pressure Transducers User s Manual T Model T Model The Swagelok T model transducer is engineered for use in industrial pressure measurement applications where intrinsically safe ratings are
More informationCompact Orifice Flow Meter
Data Sheet DS/OM Issue 2 Compact Orifice Flow Meter OriMaster Integrated DP Flow measurement system combines primary element with DP Transmitter in a single flowmeter assembly One-piece flowmeter, pressure
More informationProline Promass F 300, 500
MANUAL Special Documentation Proline Promass F 3, 5 Low-Temperature Version for Cryogenic Media SD1966O/6/EN/2.17 Material Number: 71362224 Document function Proline Promass F 3, 5 1 Document function
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70163240 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, Bayern 63911 GERMANY Attention: Harald Gollas The products listed
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationTechnical Information Cubemass
TI00106D/06/EN/13.15 71231038 Products Solutions Services Technical Information Coriolis flowmeter The ultra-compact sensor for smallest quantities with easy system integration Application Measuring principle
More informationOPTISONIC Ultrasonic flowmeter for liquids in all industrial applications
OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature
More informationATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier
Installation Instructions P/N MMI-20010152, Rev. A June 2007 for Micro Motion CMF400 Sensors with Booster Amplifier For ATEX-approved sensor installations Note: For hazardous installations in Europe, refer
More informationTechnical Information CNGmass DCI
TI00098D/06/EN/14.16 71316735 Products Solutions Services Technical Information CNGmass DCI Coriolis flowmeter The refueling application flowmeter with seamless system integration Application Measuring
More informationIntrinsic Safety Control Drawing
s Intrinsic Safety Control Drawing A5E00455287 system in total "No revision to drawing without prior Approval by FM Approvals!" PLC PC Non hazardous area PROFIBUS DP RS 485-IS Coupler PROFIBUS RS 485-IS
More informationCoriolis Mass Flow Meter Model TM
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :
More informationBrief Operating Instructions Proline Promag 50
KA0006D/06/EN/8.6 73439 Products Solutions Services Brief Operating Instructions Proline Promag 50 Electromagnetic flowmeter These Brief Operating Instructions are not intended to replace the Operating
More information[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011
Quick Installation Guide Temperature Transmitter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information Product Certifications End www.rosemount.com
More informationTechnical Information LPGmass
TI00080D/06/EN/14.15 71240750 Products Solutions Services Technical Information LPGmass Coriolis flowmeter The refueling and distribution application flowmeter with easy system integration Application
More informationTechnical Information LNGmass
TI01124D/06/EN/01.13 71231060 Products Solutions Services Technical Information LNGmass Coriolis flowmeter The flowmeter for refueling applications with simple system integration pplication Measuring principle
More informationJB/T Translated English of Chinese Standard: JB/T
Translated English of Chinese Standard: JB/T9249-1999 www.chinesestandard.net Sales@ChineseStandard.net MACHINERY INDUSTRY STANDARD OF JB THE PEOPLE S REPUBLIC OF CHINA ICS 17.120 N 12 JB/T 9249-1999 Replacing
More informationTMU. Coriolis Mass Flow Meter. for liquids and gas
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to
More informationMicro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc
ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc 5700 ATEX Installation
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationOPTIMASS / 300 / 010 Guidelines for the use of Coriolis meters in hazardous areas
OPTIMASS / 300 / 010 Guidelines for the use of Coriolis meters in hazardous areas 1000 Series Twin Straight Tube Coriolis Mass Flowmeter 2000 Series Twin Straight Tube Coriolis Mass Flowmeter 3000 Series
More informationIntrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications
More informationInstallation guide 873 SmartRadar Control Unit & Antenna Unit
Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl
More informationRosemount 753R Remote Web Based Monitoring Indicator
Rosemount 753R Remote Web Based Monitoring Indicator Product Discontinued February 2010 Start Overview Rosemount 753R with Integral 3051S Pressure Transmitter Rosemount 753R with Remote Mounted HART Transmitter
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2411253 Issued to: Balluff Incorporated 8125 Holton Dr Florence, Kentucky 41042 USA Attention: Jim Ramler The products listed below are eligible to bear the CSA Mark
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationIsolators A3/1.
> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL
More informationDescription of equipment
Applicant: Electrical Apparatus: KROHNE Messtechnik GmbH & Co. KG Level Radar BM 70M-Ex Description of equipment The Types BM 70M-Ex Level Radar gauges serve to continuously measure the product level in
More informationGeneral Specifications
General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus
More informationFisher 4200 Series Electronic Position Transmitters
Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic
More informationIECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationSingle-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More informationThe World's Most Versatile Range of. Coriolis Flowmeters
The World's Most Versatile Range of Coriolis Flowmeters 1. Adhesives No moving parts to be plugged or fouled. Bitumen Rheonik meters operate at continuous high temperature while providing high accuracy
More informationTechnical Information Condumax CLS15D/CLS15
TI0009C/07/EN/4.4 7268306 Products Solutions Services Technical Information Condumax CLS5D/CLS5 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 0.0 cm or k = 0. cm Application
More informationCondumax CLS21 and CLS21D
Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:
More informationInstallation guide 971 SmartRadar LTi
Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationFM Safety Manual. Omni-ID UHF Tags
FM Safety Manual Omni-ID UHF Tags This page is intentionally left blank. Document Number 334169 (See Last Page for Revision Details) 2012 Extronics Limited. This document is Copyright Extronics limited.
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationIndumax CLS50/CLS50D. Technical Information
Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D
More informationTechnical Information Nivector FTC968, FTC968Z
TI0007F/00/EN/7.6 7494 Products Solutions Services Technical Information Nivector FTC968, FTC968Z Capacitance Point level switch for powder and fine-grained bulk solids Application The Nivector is a small-sized
More informationAlphaline Temperature Transmitters
Alphaline Temperature Transmitters Accepts RTD and thermocouple inputs Available with an integral meter Dual compartment housing provides the highest reliability in harsh industrial environments Offers
More informationThe World's Most Versatile Range of. Coriolis Flowmeters
The World's Most Versatile Range of Coriolis Flowmeters 1. Adhesives No moving parts to be plugged or fouled. Bitumen Rheonik meters operate at continuous high temperature while providing high accuracy
More informationThe World's Most Versatile Range of. Coriolis Flowmeters
The World's Most Versatile Range of Coriolis Flowmeters 1. Adhesives No moving parts to be plugged or fouled. Bitumen Rheonik meters operate at continuous high temperature while providing high accuracy
More informationOriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple
Data sheet DS/FPD500 EN Rev. E OriMaster FPD500 Compact orifice flowmeter Orifice-based flow metering made simple Integrated DP flow measurement system, pressure tested as an assembly combines primary
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationInductive sensor slot-type SI2-K08-AP7
SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type
More informationInstallation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters
Installation Instructions P/N MMI-20011709, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters Note: For hazardous installations in Europe, refer to standard EN
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationCNGmass DCI. Technical Information. Coriolis mass flow measuring system For fueling with compressed natural gas (CNG)
Technical Information CNGmass DCI Coriolis mass flow measuring system For fueling with compressed natural gas (CNG) Applications The Coriolis measuring principle works independently of the physical fluid
More informationThe World's Most Versatile Range of. Coriolis Flowmeters
The World's Most Versatile Range of Coriolis Flowmeters 1. Adhesives No moving parts to be plugged or fouled 8. Bitumen Rheonik meters operate at continuous high temperature while providing high accuracy
More informationTechnical Information Proline Prosonic Flow B 200
TI01018D/06/EN/04.15 71310541 Products Solutions Services Technical Information Proline Prosonic Flow B 200 Ultrasonic transit time flowmeter The device for accurate, reliable biogas measurement with loop-powered
More informationBAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description
BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.
More informationTransit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P
Technical Information TI 056D/24/ae Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P Volume flow measurement of liquids in chemical or process applications Features and benefits
More informationRMA42. Technical Information
Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and
More informationProcess transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm
Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationProline Prosonic Flow B 200
Technical Information Proline Prosonic Flow B 200 Ultrasonic flow measuring system The device for accurate, reliable biogas measurement under variable process conditions Application Reliable measurement
More information