Safety Instructions Micropilot NMR81, NMR84
|
|
- Claribel Walsh
- 6 years ago
- Views:
Transcription
1 XA0436G-A/00/EN/ Products Solutions Services Safety Instructions NMR8, NMR84 CA: XP / I / / B,C,D / Tx Ta* IS / I / / A,B,C,D / Tx Ta* I / / Ex db IIC Tx Gb Ta* I / 0 / Ex ia IIC Tx Ga Ta* I / / Ex db [ia Ga] IIC / Tx Gb Ta*; Entity AIS / I,II,III / / A,B,C,D,E,F,G; Entity ANI / I,II,III / 2 / A,B,C,D,E,F,G; NIFW US: XP-IS / I / / B,C,D / Tx Ta* I / 0/ / AEx ia/db IIC Tx Ga/Gb Ta* I / / AEx db [ia Ga] IIC / Tx Gb Ta*; Entity AIS / I,II,III / / A,B,C,D,E,F,G; Entity ANI / I,II,III / 2 / A,B,C,D,E,F,G; NIFW Tx = NMR8: T4-T; NMR84: T6-T Ta*, Entity and NIFW parameters = see Safety Instructions Document: XA0436G-A Safety instructions for electrical apparatus for explosion-hazardous areas 3 Document : XA0436G-A Temperature tables 5 Document : XA0436G-A Attachment: Nameplate view 2
2 XA0436G-A 2 Endress+Hauser
3 XA0436G-A NMR8 (E-Band), NMR84 (C-Band) Table of Contents Associated documentation Extended order code Safety instructions: General Safety instructions: Special conditions Safety instructions: Installation Explosionproof/Flameproof Class I, Div. 2, Groups A-G Zone installation Safety instructions: Zone Process seals Temperature tables Connection data Endress+Hauser 3
4 XA0436G-A Associated documentation This document is an integral part of the following Operating Instructions: NMR8 BA0450G/00 NMR84 BA0453G/00 Extended order code The extended order code is indicated on the nameplate, which is affixed to the device in such a way that it is clearly visible. Additional information about the nameplate is provided in the associated Operating Instructions. Structure of the extended order code NMR8x - ************* + A*B*C*D*E*F*G* Device type Basic specifications Optional specifications * = Placeholder At this position, an option (number or letter) selected from the specification is displayed instead of the placeholders. Basic specifications The features that are absolutely essential for the device (mandatory features) are specified in the basic specifications. The number of positions depends on the number of features available. The selected option of a feature can consist of several positions. Optional specifications The optional specifications describe additional features for the device (optional features). The number of positions depends on the number of features available. The features have a 2-digit structure to aid identification (e.g. JA). The first digit (ID) stands for the feature group and consists of a number or a letter (e.g. J = test, certificate). The second digit constitutes the value that stands for the feature within the group (e.g. A = 3. material (wetted parts), inspection certificate). More detailed information about the device is provided in the following tables. These tables describe the individual positions and IDs in the extended order code which are relevant to hazardous locations. 4 Endress+Hauser
5 XA0436G-A Extended order code of the Device type NMR8, NMR84 Basic specifications Position Selected option Description, 2 Approval NMR8 FE FM C/US XP-AIS Cl.I Div. Gr.B-D, AEx d[ia] IIC T4...T detailed: FM6CA0006X: FM6US0006X: XP / I / / B,C,D / T4...T Ta* IS / I / / A,B,C,D / T4...T Ta* I / / Ex db IIC T4...T Gb Ta* I / 0 / Ex ia IIC T4...T Ga Ta* I / / Ex db [ia Ga] IIC / T4...T Gb Ta*; Entity AIS / I,II,III / / A,B,C,D,E,F,G; Entity ANI / I,II,III / 2 / A,B,C,D,E,F,G; NIFW XP-IS / I / / B,C,D / T4...T Ta* I / 0/ / AEx ia/db IIC T4...T Ga/Gb Ta* I / / AEx db [ia Ga] IIC / T4...T Gb Ta*; Entity AIS / I,II,III / / A,B,C,D,E,F,G; Entity ANI / I,II,III / 2 / A,B,C,D,E,F,G; NIFW NMR84 FC FM C/US XP-AIS Cl.I Div. Gr.B-D, AEx d[ia] IIC T6...T detailed: FM6CA0006X FM6US0006X XP / I / / B,C,D / T6...T Ta* IS / I / / A,B,C,D / T6...T Ta* I / / Ex db IIC T6...T Gb Ta* I / 0 / Ex ia IIC T6...T Ga Ta* I / / Ex db [ia Ga] IIC / T6...T Gb Ta*; Entity AIS / I,II,III / / A,B,C,D,E,F,G; Entity ANI / I,II,III / 2 / A,B,C,D,E,F,G; NIFW XP-IS / I / / B,C,D / T6...T Ta* I / 0/ / AEx ia/db IIC T6...T Ga/Gb Ta* I / / AEx db [ia Ga] IIC / T6...T Gb Ta*; Entity AIS / I,II,III / / A,B,C,D,E,F,G; Entity ANI / I,II,III / 2 / A,B,C,D,E,F,G; NIFW 5, 6 Primary Output NMR8x A Modbus RS485 B E H V 4-20mA HART Ex d/xp 4-20mA HART Ex i/is 7, 8 Secondary IO Analogue NMR8x A Ex d/xp, x 4-20 ma HART, x RTD input A2 Ex d/xp, 2x 4-20 ma HART, 2x RTD input B B2 Ex i/is, x 4-20 ma HART, x RTD input Ex i/is, 2x 4-20 ma HART, 2x RTD input C2 x Ex i /IS 4-20 ma HART, 2x RTD input + x Ex d/xp 4-20 ma HART X0 Not selected 9, 0 Secondary IO Digital Ex d/xp NMR8x A 2x relay + 2x module discrete A2 4x relay + 4x module discrete A3 B B2 B3 X0 6x relay + 6x module discrete Modbus RS485 Modbus RS x relay + 2x module discrete Modbus RS x relay + 4x module discrete Not selected Endress+Hauser 5
6 XA0436G-A Position Selected option Description 4, 5 Antenna NMR8 AB 50 mm/2 AC AD 80 mm/3 00 mm/4, align. device NMR84 BD Planar 00 mm/4 BF BG BH BJ Planar 50 mm/6 Planar 200 mm/8 Planar 250 mm/0 Planar 300 mm/2 6, 7 Process Sealing NMR8 B2 FFKM, C/ F NMR8x A HNBR C/ F B FKM GLT, C/ F Optional specifications ID Selected option Description Px Accessory Enclosed NMR8 PK Seal DN50, ANSI 2", JIS 0K 60A, adjustable PL Seal DN80, ANSI 3", JIS 0K 80A, adjustable PS PT PU Seal Adjustable, DN50 PN0-6, FKM Seal Adjustable, DN80 PN0-40, FKM Seal Adjustable, ASME 3" 50 lbs, JIS 80A 0K, FKM NMR8x PA Weather protection cover Safety instructions: General Staff must meet the following conditions for mounting, electrical installation, commissioning and maintenance of the device: Be suitably qualified for their role and the tasks they perform Be trained in explosion protection Be familiar with national regulations Install the device according to the manufacturer's instructions and national regulations. Do not operate the device outside the specified electrical, thermal and mechanical parameters. Only use the device in media to which the wetted materials have sufficient durability. Avoid electrostatic charging: Of plastic surfaces (e.g. housing, sensor element, special varnishing, attached additional plates,..) Of isolated capacities (e.g. isolated metallic plates) Refer to the temperature tables for the relationship between the permitted ambient temperature for the sensor and/or transmitter, depending on the range of application, and the temperature class. Modifications to the device can affect the explosion protection and must be carried out by staff authorized to perform such work by Endress+Hauser. Safety instructions: Special conditions Permitted ambient temperature range at the electronics housing: 40 C T a +60 C. Observe the information in the temperature tables. An antenna coated with non-conductive material can be used if avoiding electrostatic charging (e.g. through friction, cleaning, maintenance, strong medium flow). In the case of process connections made of polymeric material or with polymeric coatings, avoid electrostatic charging of the plastic surfaces. In the event of additional or alternative special varnishing on the housing or other metal parts: Observe the danger of electrostatic charging and discharge. Do not rub surfaces with a dry cloth. 6 Endress+Hauser
7 XA0436G-A Special conditions of use - US For ambient an process temperature range refer to XA0436G. Flamepath joints are not for repair. Contact the manufacturer. Use heat resisting cables rated 85 C for T a 50 C. Precautions shall be taken to minimize the risk from electrostatic discharge of non-metallic labels and isolated metal tags applied to the enclosure. To maintain the ingress protection ratings (IP66/68), teflon tape or pipe dope is required for blanking plugs. Explosionproof certified seals are required within 450 mm (8") for Group B, C, D and within 50 mm (2") for Group IIC on all used housing entries. Special conditions of use - CA This is boundary wall equipment: The XP and Ex db ratings are applicable to the transmitter portion. The IS and Ex ia ratings are applicable to the radar antenna portion. For ambient an process temperature range refer to XA0436G. Flamepath joints are not for repair. Contact the manufacturer. Use heat resisting cables rated 85 C for T a 50 C. Precautions shall be taken to minimize the risk from electrostatic discharge of non-metallic labels and isolated metal tags applied to the enclosure. To maintain the ingress protection ratings (IP66/68), teflon tape or pipe dope is required for blanking plugs. Explosionproof certified seals are required within 50 mm (2") on all used housing entries. Safety instructions: Installation A å A Division, Zone or Division 2 Tank; Division, Zone 0, Zone 2 Connection and electronics compartment AEx d/ex d 3 Power supply 4 Potential equalization line 5 Potential equalization NMR8x_0 Install the device to exclude any mechanical damage or friction during the application. Pay particular attention to flow conditions and tank fittings. Endress+Hauser 7
8 XA0436G-A Explosionproof/Flameproof Class I, Div., Groups B, C, D Class I, Zone, AEx d [ia] IIC/Ex d [ia] IIC Install per National Electrical Code (NFPA 70) or Canadian Electrical Code, Part I (C22.), as applicable. For the maximum supply voltage: 0, "Connection data" section. Control room equipment may not use or generate over 250 V rms. Seal unused entries with approved plugs that correspond to the type of protection. The plastic transport sealing plug does not meet this requirement and must therefore be replaced during installation. Antenna is intrinsically safe, AEx ia/ex ia, and suitable for installation in Class I, Div. or Class I, Zone 0/. Before operation: Screw in the cover all the way. Tighten the securing clamp on the cover. Warning: Substitution of components may impair intrinsic safety. Do not open in a potentially explosive atmosphere. Depending on approval be used, following issues to be considered: Ex d (CA) / AEx d (US) XP (C) XP (US) IIC Certified seal required within 50 mm (2") on all used housing entries Groups B, C, D; Certified seal required within 50 mm (2") on all used housing entries. Boundary wall equipment: The XP and Ex db ratings are applicable to the transmitter portion. The IS and Ex ia ratings are applicable to the radar antenna portion. Groups B, C, D; Certified seal required within 450 mm (8") on all used housing entries Class I, Div. 2, Groups A-G Device type NMR8x, Basic specification, Position, 2 (Approval) = FE and FC are not marked for use in Class I, Division 2; however, these devices are suitable for this application when installed using the explosionproof instructions for Class I, Division. Standard Wiring installation (only for NPT conduit entries) Install per the National Electrical Code (NFPA 70) or Canadian Electrical Code, Part I (C22.), as applicable, using wiring methods appropriate for the location. For the maximum supply voltage: 0, "Connection data" section. Antenna is intrinsically safe, AEx ia/ex ia, and suitable for installation in Class I, Div. or Class I, Zone 0/. Warning: Explosion hazard - Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous. Warning: Substitution of components may impair suitability for hazardous locations. Nonincendive Field Wiring (NIFW) installation The Nonincendive Field Wiring circuit concept allows interconnection of nonincendive field wiring apparatus with associated nonincendive field wiring apparatus or associated apparatus not specifically examined in combination as a system using any of the wiring methods permitted for unclassified locations, when the following conditions are met: V max V oc or V t, C a C i + C cable, L a L i + L cable. For transmitter parameters: 0, "Connection data" section. The transmitter provides a current controlled circuit; therefore, the parameter I max is not required and need not to be aligned with I sc and I t of the associated nonincendive field wiring apparatus or associated apparatus. Stated below as "current controlled". Control room equipment may not use or generate over 250 V rms. Install per National Electrical Code (NFPA 70) or Canadian Electrical Code, Part I (C22.), as applicable. Warning: Substitution of components may impair suitability for Class I, Div. 2. Always follow the installation instructions provided by the associated apparatus manufacturer. The configuration of the associated apparatus must be FM or CSA approved. 8 Endress+Hauser
9 XA0436G-A The NIFW wiring applies only for the "intrinsically safe outputs" of Main board and IOM_A : TRC[0] type "Main board" TRC[20] type "Analog module" (Ex i) The additional marking for the application is as follows: NMR84: ANI / I / 2 / A, B, C, D, E, F, G; NIFW NMR8: ANI / I / 2 / A, B, C, D, E, F, G; NIFW Zone installation Overvoltage protection against atmospheric over voltages The following Terminal outputs / configurations needs no separate external overvoltage protection measures: Position Power supply HART interface External display Terminal G E F Device configuration: Basic specification, Position 5, 6 (Primary output) = A, B, E, H Basic specification, Position 7, 8 (Secondary output IO Analog) = A, A2, B, B2, C2, X0 Basic specification, Position 9, 0 (Secondary output IO Digital Ex d) = B All other configurations must be protected by separate additional measures to comply national regulations and standards. Observe the safety instructions of used overvoltage protection. Safety instructions: Zone 0 In the event of potentially explosive vapor/air mixtures, only operate the device under atmospheric conditions. Temperature: 20 to +60 C Pressure: 80 to 0 kpa (0.8 to. bar) Air with normal oxygen content, usually 2 % (V/V) If no potentially explosive mixtures are present, or if additional protective measures have been taken, the device may also be operated under non-atmospheric conditions in accordance with the manufacturer's specifications. Process seals The following device types are Single Seal devices per ANSI/ISA and do not require the use of an external secondary process seal. Device type NMR8 NMR84 Maximum Working Pressure (MWP) for the Single Seal rating.6 MPa (6 bar) 2.5 MPa (25 bar) Temperature tables 5 Endress+Hauser 9
10 2 3 CDI POWER HR WP SIM i on XA0436G-A Connection data Connection compartment Ex d 2 E 2 D G F E D C B A CDI G 2 3 POWER F HR WP SIM on C B A Ex i Ex i G N AC V G3 L å 2 Connection for external display Ex i 2 Connection for HART interface Ex i 3 only when "Analog Ex i" installed NMR8x_02 Detailed configuration information located at the display holder. Example for lettering: Display holder Display asm. Main electr. Spare parts for: NMR 8 Ser.no.: 8A2AC098AF4 Spare part Spare no./structure Cover Display holder Display asm Main electr. XP N AABICR IOM-Mod FF XP N00 3 -B +AAA2 Slot A IOM-V/WM XP N00 3 -A + A AE Slot B IOM-AEx d XPF00 3 -D+ AAB 2 Slot C IOM-D XP N00 3 -E+ AX0A Slot D Sensor electr. XPN0038-ABICR Antenna XP N00 32-AAABA A DJ+ check spare Additional information: 2, IOM-Mod FF Slot A IOM-V/WM Slot B IOM-A Ex d Slot C IOM-D Slot D Sensor electr. å 3 Area device configuration NMR8x_03 For detailled information see Operating Instructions. 0 Endress+Hauser
11 XA0436G-A Assignment of the terminals see designation of front plane. TRC[0], type Power supply Terminal G CDI G: N G2: not connected G3: L plug connected Designation Power / Mains Local LCD, CDI (internal) non-ex (functional) U N = V AC, 50/60 Hz P N = 28.8 VA U N = 3.3 V DC P N = 4 mw TRC[0], type Main board Terminal E F E: H+ E2: H- F: Vcc F2: A F3: B F4: gnd Designation ma HART Remote display Ex [ia] non-ex (functional) NIFW U o = 29 V I o = 0 ma P o = 700 mw C o = 65 nf L o = 2.9 mh U N = 24 V DC P N 426 mw V oc = 24.5 V I sc = 33 ma P o = 498 mw C a = 42 nf L a = 73 mh U o = 3.9 V I o = 500 ma P o = 230 mw C o = 99 μf L o = 40 μh U N = 3.3 V DC P N = 4 mw V oc = 3.5 V I sc = 30 ma P o = 96 mw C a = 999 μf L a = 88 mh ) current controlled circuit TRC[32], type "Modbus" module; optional Terminal Slot A through slot D : S Cable shielding; capacitive connected to earth 2: 0V Common reference 3: B Non-inverting signal line 4: A+ Inverting signal line Designation Modbus-Slave FOUNDATION Fieldbus non-ex (functional) U N = 2 V DC P N 2 mw U M = 250 V Currently not supported Endress+Hauser
12 XA0436G-A TRC[33], type "V" module; optional Terminal Slot A through slot D : S Cable shielding; capacitive connected to earth 2: not connected 3: B Signal 4: A+ Signal + Designation V-Slave WM550 non-ex (functional) U N = 24 V DC P N 44 mw U M = 250 V Currently not supported TRC[20], type "Analog module" (Ex i); 4-20 ma HART; optional Terminal Operation mode: ma output or HART slave ma output or ma input or HART master ma input or HART master Slot B or slot C 4-wire RTD connection: Terminal 5 through 8 3-wire RTD connection: Terminal 5, 6 and 8 2-wire RTD connection: Terminal 5 and 8 Terminal active use: 2: H- 3: H+ Terminal passive use: : H- 2: H+ Designation 24 V + RTD 4-20 ma HART Ex [ia] non-ex (functional) NIFW Terminals 4-5 (24 V): U o = 29 V I o = 08 ma P o = 776 mw C o = 63 nf L o = 3.0 mh Terminals 5-8 (RTD): U o = 29 V I o = 36 ma P o = 263 mw C o = 64 nf L o = 26 mh Terminals 4-5 (24 V): U N = 24 V DC P N 600 mw Terminals 5-8 (RTD): I N = 400 μa DC P N 60 μw Terminals 4-5 (24 V): V oc = 24 V I sc = 90 ma P o = 538 mw C a = 449 nf L a = 9.9 mh Terminals 5-8 (RTD): V oc = 3.6 V I sc = 5 ma P o = 4 mw C a = 999 μf L a = 3.8 H Terminals 2-3 (Active): U o = 29 V I o = 06 ma P o = 760 mw C o = 63 nf L o = 3. mh Terminals -2 (Passive): Ui = 29 V Ii = 06 ma Pi = 760 mw C i = nf Li = 0 Terminals 2-3 (Active): U N = 24 V DC P N 540 mw Terminals -2 (Passive): U N = 29 V DC P N 653 mw Terminals 2-3 (Active): V oc = 24 V I sc = 28 ma P o = 526 mw C a = 449 nf L a = 02 mh Terminals -2 (Passive): V max = 29 V I max ) = not available P i = not available C i = nf L i = 0 ) current controlled circuit 2 Endress+Hauser
13 XA0436G-A TRC[2], type "Analog module" (Ex d); 4-20 ma HART; optional Terminal Operation mode: ma output or HART slave ma output or ma input or HART master ma input or HART master Slot B or slot C 4-wire RTD connection: Terminal 5 through 8 3-wire RTD connection: Terminal 5, 6 and 8 2-wire RTD connection: Terminal 5 and 8 Terminal active use: 2: H- 3: H+ Terminal passive use: : H- 2: H+ Designation 24 V + RTD 4-20 ma HART non-ex (functional) Terminals 4-5 (24 V): not used Terminals 5-8 (RTD): I N = 400 μa DC P N 60 μw U M = 250 V Terminals 2-3 (Active): U N = 24 V DC P N 540 mw U M = 250 V Terminals -2 (Passive): U N = 29 V DC P N 653 mw U M = 250 V TRC[3], type "Digital"; optional Terminal Operation mode: disabled passive output passive input active input Slot A through slot D Installed in slot A: : A- 2: A-2 Installed in slot B: : B- 2: B-2 Installed in slot C: : C- 2: C-2 Installed in slot D: : D- 2: D-2 3: A2-4: A2-2 3: B2-4: B2-2 3: C2-4: C2-2 3: D2-4: D2-2 Designation Relay / Digital Input/Output Relay / Digital Input/Output 2 non-ex (functional) Relay: U N = 250 V AC/DC I N 2 A Digital Input: U N = V AC/DC U M = 250 V Relay: U N = 250 V AC/DC I N 2 A Digital Input: U N = V AC/DC U M = 250 V Endress+Hauser 3
14 XA0436G-A 4 Endress+Hauser
15 XA0436G-A Temperature tables Table of Contents Notes on the structure Example diagrams of possible deratings NMR NMR Endress+Hauser 5
16 XA0436G-A Notes on the structure General notes Observe the permitted temperature range at the antenna. Observe the sealing restrictions: see Basic specification, Position 6, 7 (Process Sealing) For configurations other than listed: use configuration. Configuration of electronics: (worst case) 2 (best case) Enclosure X X X X X Slot A - IOM_D X X X X Slot B - IOM_A (Ex ia) X X X Slot C - IOM_A (Ex ia) X Slot D - IOM_D X X PS_HV X X X X X MB X X X X X ExLi X X X X X Description notes Unless otherwise indicated, the positions always refer to the basic specification.. column: Temperature classes T6 (85 C) to T (450 C) Column P to P6: Position (temperature value) on the axes of the derating 4, 7 T a : Ambient temperature in C T p : Process temperature in C P P2 P3 P4 P5 P6 ) T6 T5 T4 T3 T2 T T p T a T p T a T p T a T p T a T p T a T p T a ) Column P6 is only relevant for version B of the derating 6 Endress+Hauser
17 XA0436G-A Example diagrams of possible deratings A P T a P2 P3 T p P5 P4 B T a P P2 P3 P6 P5 P4 T p å 4 A Endress+Hauser 7
18 XA0436G-A NMR8 Configuration P P2 P3 P4 P5 P6 T p T a T p T a T p T a T p T a T p T a T p T a T T3, T2, T Configuration 2 P P2 P3 P4 P5 P6 T p T a T p T a T p T a T p T a T p T a T p T a T T3, T2, T Configuration 3 P P2 P3 P4 P5 P6 T p T a T p T a T p T a T p T a T p T a T p T a T T3, T2, T Configuration 4 P P2 P3 P4 P5 P6 T p T a T p T a T p T a T p T a T p T a T p T a T T3, T2, T Configuration 5 P P2 P3 P4 P5 P6 T p T a T p T a T p T a T p T a T p T a T p T a T T3, T2, T Endress+Hauser
19 XA0436G-A NMR84 Configuration P P2 P3 P4 P5 P6 T p T a T p T a T p T a T p T a T p T a T p T a T T T T3, T2, T Configuration 2 P P2 P3 P4 P5 P6 T p T a T p T a T p T a T p T a T p T a T p T a T T T T3, T2, T Configuration 3 P P2 P3 P4 P5 P6 T p T a T p T a T p T a T p T a T p T a T p T a T T T T3, T2, T Configuration 4 P P2 P3 P4 P5 P6 T p T a T p T a T p T a T p T a T p T a T p T a T T T T3, T2, T Configuration 5 P P2 P3 P4 P5 P6 T p T a T p T a T p T a T p T a T p T a T p T a T T T T3, T2, T Endress+Hauser 9
20 XA0436G-A 20 Endress+Hauser
21 XA0436G-A Attachment: Nameplate view Order code: Ext. ord. cd.: MWP: 6 Tp max.: 7 Ta 50 C: t 85 C 8 Mat.: 9 DeviceID: 0 Dev.Rev.: 2 ex works 3 Tank ID: Tank ref.height: Zero point: Ta: X = Date: if modification see sep. label Pos position VGR code Text Manufacturer address - - Made in Germany, Maulburg FE NMR8-23 digits, mandatory 2 Ordercode 00 FC NMR84-23 digits; mandatory 3 Serial number - - mandatory 4 Extended order code - - optional, digits not limited 5 Supply voltage B V AC (50 60 Hz) 030 D V AC / DC (50 60 Hz) depends on antenna type and process 6 Maximum process pressure - - connection depends on antenna type and process 7 Maximum process temperature - - connection A ThreadM20 B ThreadM25 8 Thread cable entry 090 E ThreadNPT/2 F ThreadNPT3/4 9 Material in contact with process - - depends on antenna type 0 Device ID - - Firmware version Device revision PTB certification number Customized parametrization data permissible ambient temperature 00 all C 6 CE mark / C-tick mark 00 all CE mark with 0700 Additional information of the marks, not relevant for Ex: e.g. C-Tick, SIL, device version 3A,..., 8 Ingress protection - - IP68 / 66, Type 4X / 6P Encl. 9 Certificate symbol FC, FE 20 FC, FE FM6US0006X XP-IS CL I DIV GP BCD T* AIS CL I,II,III DIV GP ABCDEFG ANI CL I,II,III DIV 2 GP ABCDEFG CL I Zn 0/ AEx ia/db IIC T* Ga/Gb CL I Zn AEx db [ia Ga] IIC T* Gb FM6CA0006X XP CL I DIV GP BCD T* IS CL I DIV GP ABCD AIS CL I,II,III DIV GP ABCDEFG ANI CL I,II,III DIV 2 GP ABCDEFG Ex db IIC T* Gb; Ex ia IIC T* Ga Ex db [ia Ga] IIC T* Gb T* for T-Code, Entity and NIFW Param. and Conduit seal reqs. see XA0436G 2 General certificate of approval 00 all e.g. Overspill protection; optional 22 Associated Safety Instruction (XA) 00 FC, FE XA0436G-. (actual rev.) 23 Manufacturing date 00 all YYYY-MM 24 QR code for E+H Operations App Radio Equipment RTTE no. resp. FCC-no: FCC ID: LCG NMR8X, or other or in combination; depends on Market and national regulation Type of Process sealing FC, FE Single Seal Attechment_FM_NMR Endress+Hauser 2
22 XA0436G-A 22 Endress+Hauser
23 XA0436G-A Endress+Hauser 23
24
Safety Instructions Proline Promass 300
XA01507D/06/EN/01.16 71327925 Products Solutions Services Safety Instructions Proline Promass 300 Class I, Zone 2 AEx/Ex na ic IIC Class I, Zone 2, AEx/Ex na nc ic IIC Class I Division 2 C US Document:
More informationSafety Instructions Proline Promag 500
XA01524D/06/EN/01.16 71327947 Products Solutions Services Safety Instructions Proline Promag 500 Cl.I, II, III Div.1 for XP (Ex d Flameproofed version) C US Document: XA01524D Safety instructions for electrical
More informationSafety Instructions Proline Promass 100
XA00160D/06/EN/03.14 71261250 Products Solutions Services Safety Instructions Proline Promass 100 Modbus RS485 Cl.I Div.1, Zone 1 for IS (Ex i Intrinsically safe version) C US Document: XA00160D Safety
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT
More information2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes
More informationProline Promass 40. Safety Instructions. NEPSI Zone 1, Zone 21
Safety Instructions Proline Promass 40 NEPSI Zone 1, Zone 21 This document is an integral part of the following Operating Instructions: BA00061D, Proline Promass 40 HART Contents General warnings.......................................................................
More informationPROline promag 53 Division 1
XA 040D/06/en/05.01 50099923 FM+SGML 6.0 PROline promag 53 Division 1 Ex Ex documentation for the BA 053D and BA 054D operating instructions according to FACTORY MUTUAL standards documentation for the
More informationPower supply. Calibration. Surface finishing. Seal. Process connection
Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst
More informationSafety Instructions Nivotester FTC625, FTC325
XA01351F-A/00/EN/01.14 71273077 Products Solutions Services Safety Instructions FTC625, FTC325 [Ex ia Ga] IIC/IIB TÜV 13.0903 X Segurança TÜV INMETRO OCP 0004 Document: XA01351F-A Safety instructions for
More informationFM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationEx instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,
Ex instruction manual Rotamass Coriolis mass flow meter IM 01U10X02-00EN-R_002, 2nd edition, 2016-09-22 Table of contents Table of contents 1 Introduction... 4 1.1 Scope of application... 4 1.2 Applicable
More informationFM Control Drawing Class I Division 2 / Class I Zone 2. Compact version PROMAG 10
Hazardous Locations Class I Div. 2 Groups ABCD or Class I Zone 2 Groups IIC and Class II and III Division 1 Groups EFG W / P / E / H / D / L Notes: 1. Control room equipment shall not use or generate more
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationUser's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R
User's Manual ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 Table of contents Table of contents
More informationProline Promass 83, 84
Safety Instructions Proline Promass 83, 84 NEPSI Zone 1, Zone 21 This document is an integral part of the following Operating Instructions: BA00059D, Proline Promass 83 BA00109D, Proline Promass 84 BA00063D,
More informationIntrinsic Safety Control Drawing
s Intrinsic Safety Control Drawing A5E00455287 system in total "No revision to drawing without prior Approval by FM Approvals!" PLC PC Non hazardous area PROFIBUS DP RS 485-IS Coupler PROFIBUS RS 485-IS
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL
More informationDPharp Differential Pressure and Pressure Transmitters
User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change
More informationEx instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,
Ex instruction manual Rotamass Coriolis mass flow meter ATEX IM 01U10X01-00EN-R_002, 2nd edition, 2016-09-22 Table of contents Table of contents 1 Language variants of ATEX documentation... 4 2 Introduction...
More informationCoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter
Operating Instruction OI/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter Measurement made easy Change from one to two columns Short product description Coriolis
More informationOPTIWAVE 7300 C Supplementary instructions
OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationInstallation guide 873 SmartRadar Control Unit & Antenna Unit
Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl
More informationFLEX Ex V ac In/Quad-Ex dc Out Power Supply
Installation Instructions FLEX Ex 85 250V ac In/Quad-Ex dc Out Power Supply Catalog Number 1797-PS1N Topic Important User Information 2 About the Power Supplies 3 Understand System Planning 4 Electrostatic
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More information[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011
Quick Installation Guide Temperature Transmitter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information Product Certifications End www.rosemount.com
More informationProcess transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm
Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70163240 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, Bayern 63911 GERMANY Attention: Harald Gollas The products listed
More informationPressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751
060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions
More informationAttachment to Certificate IECEx PTB X
Applicant: Electrical Apparatus: KROHNE Ltd. Measuring converter, type MFC400F Description of equipment The measuring converter, type MFC400F is used as part of a mass flow measuring system to determine
More informationInstallation guide 971 SmartRadar LTi
Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl
More informationFLEX Ex Power Supplies
Installation Instructions FLEX Ex Power Supplies (Cat. Nos. 1797-PS2N, -PS2E) About the Power Supplies The power supply is an essential component in the operation of an intrinsically safe system. It must
More informationIntrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i
Intrinsically Safe Compact Controller CTR 210i Intrinsically Safe Bargraph Indicator BGI 210i DMT 02 ATEX E 148 2. Supplement also grahics display Revision 4 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.:
More informationMODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More informationPage 1 of 5 Attachment to IECEx TUN X Issue 0
Page 1 of 5 IECEx TR: File reference: DE/TUN/ExTR12.0022/00 12 217 098526 IECEx QAR: File reference: DE/QAR/TUN/06.0002/04 QAR TUN 04.0002 The microwave sensors type series VEGAFLEX FX8*(*).*D****A/H/B/I/U*****
More informationSingle-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationPRODUCT SPECIFICATION AND MODEL SELECTION GUIDE
XYR 5000 Wireless Temperature Transmitters WT530 34-XY-03-02 09/2006 PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The WT530 Temperature Transmitter is part of the XYR 5000 family of wireless
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature
More informationGeneral Specifications
General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus
More informationInstallation guide 877 FDI Field Display & Interface
Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com
More informationCertificate of Conformity
Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocol:
More informationMCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol
SIL IEC 6 508 Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol Data Sheet 0068_en_03 PHOENIX CONTACT 0-07-09 Description Temperature FL ϑ Universal PC programmable
More informationProduct manual wire programmable RTD transmitter
Product manual 5332 2-wire programmable RTD transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 5332V100-UK From serial no: 181903001
More informationProcessMaster, HygienicMaster FEX300, FEX500
SM/FEX300/FEX500/FM/CSA-EN ProcessMaster, HygienicMaster FEX300, FEX500 FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual
More informationLoop Powered Indicator
Instruction Manual Model PD686 Loop Powered Indicator M397 January 3, 2019 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Tel: 978-486-9800 Fax: 978-486-0170 PD686 I.S. and N.I. NEMA 4X, IP67
More informationTemperature Measurement
Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationServo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.
Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell Enraf s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It
More informationUser's Manual Model SE14 Magnetic Flow Converter
User's Manual Model SE14 Magnetic Flow Converter Manual Change No. 09-001-6E Please use attached sheets for the pages listed below in (7th). Page Page 10-2 EMC Conformity Standards Contents Changed the
More informationRosemount 5400 Series Radar Level Transmitter
Radar Level Transmitter Start Step 1: Mount the Transmitter Step 2: Connect the Wiring Step 3: Configure Confirm Configuration End HART 00825-0100-4026I www.rosemount.com 2007 Rosemount Inc. All rights
More informationRosemount 3101, 3102, and 3105
Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as
More informationRADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below
BLISSFLEX 1100 The characters of the order code have been described below BA25 4 BLISSFLEX 1100 C 2-wire loop-powered 4...20 ma Guided Radar (TDR) level meter: -50...+100 C and -1...16 barg / -58...212
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationInstallation guide 970 SmartRadar ATi
Installation guide 970 SmartRadar ATi July 2008 Part no. 4416.717 Rev. 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com Website
More informationATEX Installation Drawings and Instructions
Installation Instructions P/N 20004414, Rev. C September 2008 ATEX Installation Drawings and Instructions For ATEX-approved transmitter installations Note: For hazardous installations in Europe, refer
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers
Instruction Manual Supplement DVC6005 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Hazardous Area Approvals and Special Instructions
More informationCertificate of Conformity
Applicant: Moore Industries International Inc. 16650 Schoenborn Street North Hills CA 91343-6196 U.S.A Electrical Apparatus: Fully Encapsulated PC-Programmable Temperature Transmitters (TRX: nonisolated;
More informationIP26 Series Current to Pneumatic Converter
Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationIndustrial Pressure Transducers
Industrial Pressure Transducers User s Manual T Model T Model The Swagelok T model transducer is engineered for use in industrial pressure measurement applications where intrinsically safe ratings are
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2411253 Issued to: Balluff Incorporated 8125 Holton Dr Florence, Kentucky 41042 USA Attention: Jim Ramler The products listed below are eligible to bear the CSA Mark
More informationProcessMaster / HygienicMaster
SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual Standards
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationINSTALLATION AND OPERATION MANUAL
Version 2.2 MS1016 MTF SERIES VIBRATING PROBES FOR LIQUIDS AND HYC-PKK-312 SWITCHING ISOLATOR INSTALLATION AND OPERATION MANUAL Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire,
More informationRosemount 648 Wireless Temperature Transmitter
Rosemount 648 Wireless Temperature Transmitter with Rosemount X-well Technology Product Data Sheet July 2016 00813-0100-4648 Rev GD Rosemount X-well Technology provides accurate process temperature without
More informationHead mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More information600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet
Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More information600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)
Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically
More informationEmerson (Appleton Group ATX)
These assemblies are available in AC-powered and DC-powered versions. They have space to land 48 or 96 CHARM I/O depending on the model chosen. The field I/O can be specified as either IS or NON-IS I/O.
More informationInstallation guide 854 XTG Level Gauge
Installation guide 854 XTG Level Gauge July 2008 Part no. 4416.276 Rev. 5 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com
More informationQuick Start Guide , Rev CA April Rosemount 4088A MultiVariable Transmitter. with Modbus Output Protocol
00825-0100-4088, Rev CA Rosemount 4088A MultiVariable Transmitter with Modbus Output Protocol Safety messages NOTICE This guide provides basic guidelines for the Rosemount 4088 MultiVariable Transmitter.
More informationTF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples
More informationArmstrong Intelligent Monitoring Installation and Operation Manual
Armstrong Intelligent Monitoring Installation and Operation Manual Models: AD5000, ST5700, TD5100 IOM-256-B Please read and save these instructions Installation and Set Up Overview Warning: Lithium Batteries
More informationABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. TTF200 Field-mount temperature transmitter
ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET TTF200 Field-mount temperature transmitter 2 TTF200 FIELD-MOUNT TEMPERATURE TRANSMITTER DS/TTF200-EN REV. B Measurement made easy Temperature transmitter
More informationENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.
ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging. Technical Specifications Data Communication Honeywell Bi-phase mark (Pos 2 = E and I) 1200 / 2400 bps > 1,500 V Full galvanic separation via isolating
More informationJM Enclosure Dimensions (in mm)
ub #0revB process networking solutions Junction Module (JM ) Enclosure with: FOUNDATION Fieldbus Input/Output Module (JMM9 ) These I/O Modules are designed to function as FOUNDATION Fieldbus nodes with
More informationAH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions
AH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Models AH71, AH72, and AH73 are
More informationIntrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751
Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable
More informationIECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationRosemount 248 Wireless Temperature Transmitter
Rosemount 248 Wireless Temperature Transmitter Product Data Sheet November 2014 00813-0100-4248, Rev CC Standard temperature transmitter offers a wireless solution for process monitoring Optimize plant
More informationYTA610 and YTA710 Temperature Transmitter (Hardware)
User s Manual YTA610 and YTA710 Temperature Transmitter (Hardware) 2nd Edition 1 YTA610 and YTA710 Temperature Transmitter (Hardware) 2nd Edition CONTENTS 1. Preface... 1-1 Notes on the User s Manual...1-1
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationExpert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters
Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationSpecial Documentation Levelflex FMP51, FMP52, FMP55, FMP57
SD01328F/00/EN/02.14 71267123 Products Solutions Services Special Documentation Levelflex FMP51, FMP52, FMP55, FMP57 Guided Level Radar Installation and operating instructions for marine approval Levelflex
More informationTechnical Information RMA42
TI00150R/09/EN/05.16 71315973 Products Solutions Services Technical Information RMA42 Process transmitter with control unit Digital process transmitter for monitoring and visualizing analog measured values
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationThie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:
Page: 1 of 3 - - 2003 Date Name Name 27.03.03 Thiem. Title FM/CSA-Control-Document Appr. / 5 08.07.11 Thie. Std. 4 07.10.09 Lasa. 3 26.06.06 Thie. Drwg.-No. (Part-No.) 2 22.05.06 Thie. 901265 1 27.03.
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationRosemount 5600 Series Radar Level Transmitter with HART and Foundation fieldbus protocol
Radar Level Transmitter with HART and Foundation fieldbus protocol Start Step : Mount the Transmitter Step 2: Connect Wiring and Power Up Step : Configure the Transmitter Product Certifications Confirm
More informationUser s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th).
User s Manual Model DY Vortex Flowmeter (Integral Type, Remote Type) Model DYA Vortex Flow Converter (Remote Type) FOUNDATION Fieldbus Communication Type Manual Change No.14-013V-E Please use the attached
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More information