Temperature Transmitters

Size: px
Start display at page:

Download "Temperature Transmitters"

Transcription

1 Temperature Transmitters measuring monitoring analysing KM O O Wide supply voltage range: V DC O O Operation, visualisation and maintenance via PC Universal setting with HART protocol T O O Fault signal on sensor break or short circuit, presettable to NAMUR NE Owire O technology,... 0 ma analog output High accuracy Application Linearised temperature measurement Resistance thermometers Thermocouples Resistance Voltage Connection head according to DIN 79 form B or DINrail /06 07 KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring D6579 Hofheim/Ts. Head Office: 9(0) (0)69 98 info.de@kobold.com

2 Temperature Transmitters Model KM Description Transmitters for head mounting model KM, transform resistance values or thermal voltage into a standard current signal... 0 ma. Transmission is absolute interferencefree over long distances.different sensor inputs are Resistance thermometers, Thermocouples, Resistance and Voltage. Programming of measuring ranges is via Upro and HART protocol. Connection head for mounting these Upro transmitters is according to DIN 79 form B. Technical Details KM0 (only Pt00) Supply voltage: Input type: V DC x Pt00 wires (acc. to IEC 6075) 0.5 ma Sensor current: Range limit: ºC Min. mesasuring range: 0 K Output signal:... 0 ma Max. load: (supply 7.5 V) / 0.0 A Signal on alarm: under range: linear drop to.8 ma over range: linear rise to 0.5 ma sensor open or short circuit:.6 ma or ma Accuracy: 0. K or 0.% of span Response time: s Test conditions: calibration temperature: ºC (7. K) ±5 K Long term stability: 0.05% / year Switch on delay: 5 s Resolution: µa Ambient temperature: ºC Storage temperature: ºC Degree of protection: enclosure IP 66, terminals IP 00 Relative humidity: < 95% RH (noncond.) Shock and vibration resistance: g / Hz as per IEC Electromagnetic compatibility (EMC): Dimensions: Weight: acc. to GB/T , compliance with IEC 66:005 mm x 8 mm approx. 7 g Housing: PC and potting silicone Applied harmonised standards and normative documents: IEC 6059: Degree of protection provided by housing (IPCODE) IEC 600: Safety requirements for electrical measurement IEC 66: Electromagnetic compatibility (EMC requirements) NAMUR: Standard working group for measurement and control technology in the chemical industry PC PC /06 07

3 Temperature Transmitters Model KM KM and KM6 Series Input Sensor Measurement ranges Min. meas. ranges Resistances thermometer Pt00 Pt500 Pt000 acc. to IEC ºC ( ºF) ºC ( ºF) ºC ( ºF) 0 ºC 0 ºC 0 ºC Cu50 Cu00 Ni00 Ni500 Ni000 acc. to DIN 760 Resistance Resistance Ω Ω Ω Connection type:, or wire connection Sensor current: 0.5mA Thermocouples (TC) Voltage transmitters (mv) B(PtRh0PtRh6) E(NiCrCuNi) J(FeCuNi) K(NiCrNi N(NiCrSiNiSi R(PtRhPt) S(PtRh0Pt) T(CuCuNi) (mv) ºC ( ºF) ºC ( ºF) ºC ( ºF) ºC ( ºF) ºC ( ºF) ºC (... 08ºF) ºC ( ºF) ºC ( ºF) ºC ( ºF) ºC ( ºF) ºC (58... ºF) ºC (58... ºF) ºC ( ºF) mv mv mv mv 0 ºC 0 ºC 0 ºC 0 ºC 0 ºC 0 Ω 0 Ω 500 K 500 K 500 K 5 mv 5 mv 0 mv 0 mv /06 07 Supply voltage: V DC Output signal:... 0 ma Max. load: max. (supply 7.5 V) / 0.0 A Signal on alarm: under range: linear drop to.8 ma over range: linear rise to 0.5 ma sensor open or short circuit:.6 ma or ma Linearisation/transmission behaviour: temperature linear, resistance linear, voltage linear Galvanic isolation: U= KV AC (input/output) only KM, KM5, KM6, KM665 Response time: 0.5 s Long term stability: RTDs ±0.% of reading or 0. ºC whichever is greater, for months. Thermocouples ±0.% of reading or 0. ºC whichever is greater, for months Switch on delay: < s Influence of ambient: negligible Load influence: ±0.0%/00 Ω, values refer to the full scale value Power supply influence: negligible Self stability configuration: 0... % Filter configurating: µa Resolution: 0. µa Accuracy Input Sensor Accuracy RTD TC Ω mv Pt00, Ni00 Pt500, Ni500 Pt000, Ni000 Cu50 Cu00 K,J,T,E N S,B,R 0 to 00Ω 0 to 000Ω 0 to 75mV 00 to 000mV 00 to 500mV 00 to 000mV 0.0% 0.05% 0.% 0.% 0.% typ. 0.% of span typ. 0.% of span typ. 0.% of span ±0. Ω or 0.0% ±.5 Ω or 0.0% ± µv or 0.0% ± µv or 0.0% ± 7.5 µv or 0.0% ± 7.5 µv or 0.0%

4 Temperature Transmitters Model KM Installation instructions: installation angle: no limit installation area: connection head according to DIN 79 Form B or DINrail Ambient temperature: ºC ( ºF) Storage temperature: ºC (0... ºF) Degree of protection: enclosure IP 66, terminals IP 00 (head mounting) IP 0 (DINrail) Relative humidity: < 95% RH (noncond.) Shock and vibration resistance: Electromagnetic compatibility (EMC): g / Hz as per IEC inteference immunity and interference emission according to IEC 66:006 Dimensions: KM Series: Ø x.5 mm; KM6 Series:.6 x 99 x.5 mm Weight: KM Series: approx..5 g; KM6 Series: approx. 80 g Housing: KM Series: PC and potting silicone; KM6 Series: PC Applied harmonised standards and normative documents: IEC 6059: degree of protection provided by housing (IPCODE) IEC 600: safety requirements for electrical measurement IEC 66: electromagnetic compatibility (EMC requirements) NAMUR: standard working group for measurement and control technology in the chemical industry /06 07

5 Temperature Transmitters Model KM Wiring Diagram KM VDC... 0mA wire PT00 KMSeries VDC... 0mA () () KM660 and KM66 () () TC mv Resistance wire RTD wire RTD wire RTD VDC... 0mA () () () () TC mv Resistance wire RTD wire RTD wire RTD KM VDC... 0mA () () () () TC mv Resistance wire RTD wire RTD wire RTD /

6 Temperature Transmitters Model KM Order Details (Example: KM0) Model* Input Output Galvanic isolation Programming mode ** KM0 Pt ma No Upro KM0 No Upro KM Pt00, Pt500, Pt000. (acc. to IEC 6075) Cu0, Cu00 Yes Upro KM5 Ni00, Ni500, Ni000 (acc. to DIN 760) Yes HART... 0 ma KM660 TC: B, E, J, K, N, R, S, T (acc. to IEC 58) No Upro KM66 Resistance: Ω, Ω Voltage: mv, mv Yes Upro KM665 Yes HART * Add suffix "V" if factory setting of desired measuring range is required ** For programming the transmitters use a standard HART modem. Models with Upro don t support HandHeld HART Communicator Accessories (for programming the transmitters with programming modes Upro / HART ) Model Description HARTCOMM (includes configuration software KMSoft) HART modem * Download software KMSoft free of charge from Dimensions [mm] KM0 8 KM Series.5 Ø Ø KM6 Series /06 07

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p Resisitve Sensor hygienic design measuring monitoring analysing LTS Measuring range: -50 +250 C Accuracy Class A according to DIN IEC 751 p max : 10 bar Process connection: G ½ standard, G ½ or M cavity

More information

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy

More information

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15... Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000

More information

Full Metal Variable Area Flowmeter and Counter Model BGF

Full Metal Variable Area Flowmeter and Counter Model BGF Full Metal Variable Area Flowmeter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF OO Measuring range: 10-100... 6000-60000 l/h water 0.3-3.0... 170-1700 m³/h air (20

More information

Magnetic Inductive Flowmeter

Magnetic Inductive Flowmeter Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange

More information

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0... Electronic Flow Monitor for liquids measuring monitoring analysing KAL-K Range: approx. 4-200 cm/s p max : 100 bar Temperature of medium: -20... +80 C Option: 0... +120 C Process connection: G ¼, G ½,

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

NGR. Guided Wave Radar Level Transmitter

NGR. Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter measuring monitoring analyzing NGR For Liquids Operates Independent of Density, Temperature, Pressure, Humidity, and Conductivity Standard Measuring Length: 6. Ft (Longer

More information

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version Inductive Conductivity/ Concentration and Temperature Transmitter measuring monitoring analysing LCI or separate version Activation of up to four measuring ranges (up to 2000 ms/cm) Concentration measurement

More information

COMPACT-LINE. Transmitter for ph-value

COMPACT-LINE. Transmitter for ph-value Transmitter for ph-value measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential) and temperature Simple

More information

Electromagnetic flowmeter in all metal design Model MIM

Electromagnetic flowmeter in all metal design Model MIM Electromagnetic Flowmeter all metal design measuring monitoring analysing MIM O O For measuring and monitoring of conductive liquids OAccuracy: O < ± (0.8% of reading + 0.5% of full scale) O O Flow and

More information

Level Sensors Reed Contact Chain

Level Sensors Reed Contact Chain Level Sensors Reed Contact Chain measuring monitoring analysing Measuring length: Measuring accuracy: 0.5% for L = 2000 mm Pressure: max. 20 bar Temperature: max. 130 C Connection: G 3 8 to G 2 flange:

More information

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases All Metal Variable Area Flowmeter for Liquids and Gases measuring monitoring analysing : 0.1-1... 20-200 water 3-30 Nm3/h... 600-6000 Accuracy: ±3 % of full p max : 420 bar; t max : 130 C Connection: ¼"

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit measuring monitoring analysing DUK Measuring range: 0.08-0. - 630 L /min Accuracy: ±. % of F.S. Range span: 0 p max : 6 bar; t max : 90 C Connection:

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C Coriolis Massflowmeter for liquids and gases measuring monitoring analysing TME OMeasuring O range: 0-60 kg/h 0-60000 kg/h water O O Accuracy: ±0.15 of reading ± zero-point stability OO p max : PN40 t

More information

itemp HART DIN rail TMT112

itemp HART DIN rail TMT112 Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application

More information

Insertion Thermocouples with Bayonet Lock

Insertion Thermocouples with Bayonet Lock Insertion Thermocouples with Bayonet Lock measuring monitoring analysing Measuring ranges: 0... +400 C Bulbs in stainless steel 1.4571 NiCr-Ni or Fe-CuNi thermocouples Accuracy class 2 (option category

More information

Liquid Level Switches

Liquid Level Switches Liquid Level Switches According to the Tuning Fork Principle measuring monitoring analysing N Repeatability: ± mm pmax: 45 bar tmax: 30 C, 50 C (for CIP process) Connections: Pipe screw joints, NPT, Flange,

More information

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22 Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)

More information

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

DVZ. Vortex Flowmeter Compact. for low viscosity liquids Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0. -4. 0-00 L/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼...G, ¼" NPT..." NPT

More information

Temperature Transmitters - Head Mounted

Temperature Transmitters - Head Mounted XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z KOBO-RP Transmitter for ORP Model ARM-Z measuring monitoring analysing COMPACT-LINE Measuring range -1999 to +1999 mv Switchable from ORP to ph ph or mv/orp (Oxidation Reduction Potential) and temperature

More information

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de TT2780 Data Sheet TT2780

More information

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z KOBO-pH Transmitter for ph-value Model APM-Z measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential)

More information

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X KOBO-pH Transmitter for ph-value and ORP Model APM-X measuring monitoring analysing EXPERT-LINE Measuring range: ph value: 0 to 14 ORP: -1500 to +1500 mv (0-100%) For general-purpose use with: Analogue

More information

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp PCP TMT 181 Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

Temperature Transmitters - DIN Rail Mounted

Temperature Transmitters - DIN Rail Mounted XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water) Turbine Wheel Flowmeter Plastic Model for Liquids measuring monitoring analyzing TUR TUR with Transmitter TUR with ADI-1 Measuring Ranges: 5.3...88 GPM or 11...440 GPM (Water) Measuring Accuracy: ± 1%

More information

Temperature measurement TMD 832 head transmitter

Temperature measurement TMD 832 head transmitter Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications

More information

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

MIM. Electromagnetic Flowmeter. Compact, All-metal Design Electromagnetic Flowmeter Compact, All-metal Design measuring monitoring analyzing MIM For Measurement and Monitoring of Conductive Liquids Flow and Temperature Measurement Switching, Transmitting, and

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

Electronic Flow Monitor

Electronic Flow Monitor Electronic Flow Monitor for Liquids measuring monitoring analysing Range: approx. 4200 cm/s Max. pressure: 100 bar Temperature of medium: 20...+80 C Option: 0...+120 C Processconnection: G 1 4...G 1 1

More information

itemp PA TMT184 Technical information

itemp PA TMT184 Technical information Technical information itemp PA TMT184 Temperature head transmitter with PROFIBUS-PA interface. Supply and digital communication using PROFIBUS-PA, for installation in a Form B sensor head. Features and

More information

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs Digital ressure Sensor LED Display with Switch & Analog Outputs measuring monitoring analyzing SD Measuring Range: 0...30 to 0...7500 SI Temperature Range: -13...185 F Accuracy (at 77 F): ± 0.5 % FS Connection:

More information

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters The 520 transmitters are universal, isolated, dual-input temperature transmitters with additional voltage and resistance

More information

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting All-Metal Armored Variable Area Flowmeter and talizer for Horizontal or Vertical Mounting measuring monitoring analyzing BGF Measuring Range: 0.044...0.44 to 26.4...264 (Water) 0.176...1.76 to 100...1000

More information

Frame through-beam sensors

Frame through-beam sensors Frame through-beam sensors Features Wide range of sizes: passage sizes from 25 x 23 mm to 300 x 397.5 mm Metal housings Integrated evaluation unit Connection by means of connector Degree of protection

More information

DUK. Compact Ultrasonic Flowmeter

DUK. Compact Ultrasonic Flowmeter Compact Ultrasonic Flowmeter measuring monitoring analyzing DUK Measuring Ranges: 0.0... GPM to 0.6...60 GPM Accuracy: ±0.7 % of Reading + ±0.7% of F.S. Turndown Ratio: 0: P max : 30 PSI; T max : 48 F

More information

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature Transmitter itemp RTD DIN rail TMT 127 Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed

More information

Through-beam ring sensors

Through-beam ring sensors Throughbeam ring sensors Features Wide range of sizes: ring diameters of 10, 15 and 20 mm Metal housings Separate evaluation unit Connection by means of S8 connector Degree of protection IP 63 Adjustable

More information

Temperature head transmitter itemp TC TMT 188

Temperature head transmitter itemp TC TMT 188 Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed

More information

2-channel speed sensor GEL 247 Compact sensor for harsh applications

2-channel speed sensor GEL 247 Compact sensor for harsh applications 2-channel speed sensor GEL 247 Compact sensor for harsh applications Technical information Version 01.11 General Speed sensor based on magnetic measurement principle Maintenance- and wear-free operation

More information

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,

More information

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring Technical information itemp Pt100 TMT127 Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring Application Temperature transmitter with fixed measuring range for converting a

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and

More information

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp PCP TMT 181 Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

Analogue Temperature Transmitter

Analogue Temperature Transmitter TE 19.01 Electrical Temperature Measurement Analogue Temperature Transmitter Configurable Ranges, Head Mounting for Pt100 Resistance Thermometers for Thermocouples Applications Plant construction Power

More information

OPTITEMP TT 20 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is

More information

Temperature transmitter with local display RIT 261

Temperature transmitter with local display RIT 261 Technical Information TI 091R/2/ae Temperature transmitter with local display RIT 261 Universal field mounted transmitter provides an exceptional backlit temperature indication with five large digits and

More information

P5201 Universal Programmable Transmitters with Galvanic Isolation

P5201 Universal Programmable Transmitters with Galvanic Isolation Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to

More information

The compact test- disconnect terminal interface system for protection and secondary technology

The compact test- disconnect terminal interface system for protection and secondary technology POCON POWER Connector The compact test- disconnect terminal interface system for protection and secondary technology POCON the compact test-disconnect terminal interface system Safe control and testing

More information

Temperature transmitter itemp RTD DIN rail TMT 127

Temperature transmitter itemp RTD DIN rail TMT 127 Technical information TI 095R/24/ae Nr. 510 06165 Temperature transmitter itemp RTD DIN rail TMT 127 Pt100 transmitter for an economical, high accuracy temperature monitoring. Fixed range measurement,

More information

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9211E 4-Channel Thermocouple Input Module This document describes how to use the National Instruments 9211E and includes dimensions, terminal assignments, and

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC) Technical information itemp TC TMT128 DIN rail mounted Temperature Transmitter for Thermocouples (TC) Application Temperature transmitter with fixed measuring ranges for converting TC input signals into

More information

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER RTD, THERMOCOUPLE, THERMISTOR (BMS SENSORS), SLIDE WIRE, mv AND RESISTANCE INPUTS ma, VOLTAGE OR BIPOLAR VOLTAGE OUTPUT SENSOR OFFSET (TEMPERATURE) 22 SEGMENT USER LINEARISATION (PROCESS) CONFIGURATION

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

SMART TEMPERATURE TRANSMITTERS. smar

SMART TEMPERATURE TRANSMITTERS. smar SMART TEMPERATURE TRANSMITTERS FEATURES Single unit accepts signal from: - Standart RTDs and Thermocouples - Single ended or differential sensing - mv signals from radiation pyrometers, load cells, etc.

More information

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. Parametrization interface. Power Bus Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and

More information

Transmitter. Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter. Application Areas. Features and Benefits

Transmitter. Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter. Application Areas. Features and Benefits Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter The Series 440 programmable RTD temperature transmitter is a 2-wire transmitter with an analog output. It has measurement input

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

Rail mounted Temperature Transmitter TH102/TH102-Ex

Rail mounted Temperature Transmitter TH102/TH102-Ex Data Sheet 10/-8.54 EN Rail mounted Temperature Transmitter TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples

More information

HART field temperature transmitter Models TIF50, TIF52, TIF62

HART field temperature transmitter Models TIF50, TIF52, TIF62 Electrical temperature measurement HART field temperature transmitter Models TIF50, TIF52, TIF62 WIKA data sheet TE 62.01 Applications Plant construction Process engineering General industrial applications

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

The Rosemount 848T Wireless Temperature Transmitter

The Rosemount 848T Wireless Temperature Transmitter Rosemount 88T Family February 0 The Rosemount 88T Wireless Temperature Transmitter The Rosemount 88T is the premier choice for Wireless High Density measurements. Four independently configurable inputs

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

SINEAX V 604s Programmable multifunctional transmitter

SINEAX V 604s Programmable multifunctional transmitter SINEAX V 60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers 00 SINEAX V60s is a multifunctional transmitter f top-hat rail assembly with the following main characteristics:

More information

for installation into terminal head form B and for installation on DIN rail Output signals : 4 to 20 ma : 4 to 20 ma 0 to 10 V

for installation into terminal head form B and for installation on DIN rail Output signals : 4 to 20 ma : 4 to 20 ma 0 to 10 V sales@jumo.co.uk info.us@jumo.net Page 1/12 JUMO dtrans T0 Programmable twowire transmitter for installation into terminal head form B and for installation on DIN rail Brief description The transmitters

More information

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO

More information

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module This document describes how to use the National Instruments 9207E and includes dimensions, pin assignments,

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

Process Control HPP-25

Process Control HPP-25 Process Control HPP-25 Riveting process monitoring 6 different control parameters Touchscreen operation Windows diagnostics software Industrie 4.0 ready...joining is our business worldwide! Process Control

More information

High-precision process calibrator Model CED7000

High-precision process calibrator Model CED7000 Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO

More information

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9213E 16-Channel Thermocouple Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9213E 16-Channel Thermocouple Input Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9213E 16-Channel Thermocouple Input Module This document describes how to use the National Instruments 9213E and includes dimensions, terminal assignments,

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

HART Compatible Intelligent 2-wire DIN Rail Transmitters

HART Compatible Intelligent 2-wire DIN Rail Transmitters HART Compatible Intelligent 2-wire DIN Rail Transmitters MESO-L is a Smart and universal 2-wire DIN Rail transmitter for temperature and other measurement applications. MESO-LX is the Intrinsic Safe version

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

Technical Information itemp TMT180

Technical Information itemp TMT180 TI00088R/09/EN/14.16 71315611 Technical Information itemp TMT180 Temperature head transmitter for resistance thermometers Pt100 Configurable using a PC, for installation in a terminal head, form B Application

More information

Paperless Recorder PR20

Paperless Recorder PR20 Technical Information TI 075R/24/ae Paperless Recorder PR20 Economical and time saving recorder operates without the need for paper or pens and is exceedingly simple to operate Application Areas Technological

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

Miniature resistance thermometer Model TR33, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted Electrical temperature measurement Miniature resistance thermometer Model TR33, thread-mounted WIKA data sheet TE 60.33 Applications Machine building, plant and vessel construction Propulsion technology,

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature SITRANS T measuring instruments for temperature /2 Product overview /6 Transmitter for mounting in sensor head /6 SITRANS TH100, two-wire system (Pt100) /9 SITRANS TH200, two-wire system universal /15

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Multifunction Intelligent 4-wire Isolated Signal Conditioner Multifunction Intelligent 4-wire Isolated Signal Conditioner IPAQ-4L is a fully universal and intelligent 4- wire (mains powered) transmitter for temperature measurement and signal conditioning applications.

More information